Carel 2750441 Small Rack Control PRK300S3Fk User Manual
Carel 2750441, likely a PRK300S3FK model, is a compressor rack controller. It manages scroll, reciprocating, and screw compressors, offering advanced features like inverter control, scheduling, and alarm management. Multiple languages and pressure unit options are available. The device features a built-in display and USB connectivity.
PDF
Download
Document
Advertisement
Advertisement
pRack pR300 compressor rack controller User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT! H i g h E f f i c i e n c y S o l u t i o n s ENG IMPORTANT DISPOSAL CAREL bases the development of its products on decades of experience in HVAC, on the continuous investments in technological innovations to products, procedures and strict quality processes with in-circuit and functional testing on 100% of its products, and on the most innovative production technology available on the market. CAREL and its subsidiaries nonetheless cannot guarantee that all the aspects of the product and the software included with the product respond to the requirements of the final application, despite the product being developed according to start-of-the-art techniques. The customer (manufacturer, developer or installer of the final equipment) accepts all liability and risk relating to the configuration of the product in order to reach the expected results in relation to the specific final installation and/or equipment. CAREL may, based on specific agreements, act as a consultant for the positive commissioning of the final unit/application, however in no case does it accept liability for the correct operation of the final equipment/system. Fig. 1 Fig.2 Please read and keep. With reference to European Union directive 2012/19/EU issued on 4 July 2012 and related national legislation, please note that: 1. Waste Electrical and Electronic Equipment (WEEE) cannot be disposed of as municipal waste but must be collected separately so as to allow subsequent recycling, treatment or disposal, as required by law; 2. users are required to take Electrical and Electronic Equipment (EEE) at end-oflife, complete with all essential components, to the WEEE collection centres identified by local authorities. The directive also provides for the possibility to return the equipment to the distributor or retailer at end-of-life if purchasing equivalent new equipment, on a one-to-one basis, or one-to-zero for equipment less than 25 cm on their longest side; 3. this equipment may contain hazardous substances: improper use or incorrect disposal of such may have negative effects on human health and on the environment; 4. the symbol (crossed-out wheeled bin – Fig.1) even if, shown on the product or on the packaging, indicates that the equipment must be disposed of separately at end-of-life; 5. if at end-of-life the EEE contains a battery (Fig. 2), this must be removed following the instructions provided in the user manual before disposing of the equipment. Used batteries must be taken to appropriate waste collection centres as required by local regulations; 6. in the event of illegal disposal of electrical and electronic waste, the penalties are specified by local waste disposal legislation. The CAREL product is a state-of-the-art product, whose operation is specified in the technical documentation supplied with the product or can be downloaded, even prior to purchase, from the website www.CAREL.com. Each CAREL product, in relation to its advanced level of technology, requires setup / configuration / programming / commissioning to be able to operate in the best possible way for the specific application. The failure to complete such operations, which are required/indicated in the user manual, may cause the final product to malfunction; CAREL accepts no liability in such cases. Only qualified personnel may install or carry out technical service on the product. The customer must only use the product in the manner described in the documentation relating to the product. In addition to observing any further warnings described in this manual, the following warnings must be heeded for all CAREL products: • Prevent the electronic circuits from getting wet. Rain, humidity and all types of liquids or condensate contain corrosive minerals that may damage the electronic circuits. In any case, the product should be used or stored in environments that comply with the temperature and humidity limits specified in the manual. • Do not install the device in particularly hot environments. Too high temperatures may reduce the life of electronic devices, damage them and deform or melt the plastic parts. In any case, the product should be used or stored in environments that comply with the temperature and humidity limits specified in the manual. • Do not attempt to open the device in any way other than described in the manual. • Do not drop, hit or shake the device, as the internal circuits and mechanisms may be irreparably damaged. • Do not use corrosive chemicals, solvents or aggressive detergents to clean the device. • Do not use the product for applications other than those specified in the technical manual. Warranty on the materials: 2 years (from the date of production, excluding consumables). Approval: the quality and safety of CAREL INDUSTRIES Hqs products are guaranteed by the ISO 9001 certified design and production system. WARNING: separate as much as possible the probe and digital input signal cables from the cables carrying inductive loads and power cables to avoid possible electromagnetic disturbance. Never run power cables (including the electrical panel wiring) and signal cables in the same conduits. All of the above suggestions likewise apply to the controllers, serial boards, programming keys or any other accessory in the CAREL product portfolio. CAREL adopts a policy of continual development. Consequently, CAREL reserves the right to make changes and improvements to any product described in this document without prior warning. NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT! The technical specifications shown in the manual may be changed without prior warning. The liability of CAREL in relation to its products is specified in the CAREL general contract conditions, available on the website www.CAREL.com and/or by specific agreements with customers; specifically, to the extent where allowed by applicable legislation, in no case will CAREL, its employees or subsidiaries be liable for any lost earnings or sales, losses of data and information, costs of replacement goods or services, damage to things or people, downtime or any direct, indirect, incidental, actual, punitive, exemplary, special or consequential damage of any kind whatsoever, whether contractual, extra-contractual or due to negligence, or any other liabilities deriving from the installation, use or impossibility to use the product, even if CAREL or its subsidiaries are warned of the possibility of such damage. Key icone NOTE: IMPORTANT: TUTORIAL: 3 to bring attention to a very important subject; in particular, regarding the practical use of the various functions of the product. to bring critical issues regarding the use of the pRack pR300 to the attention of the user. some simple examples to accompany the user in configuring the most common settings. pRack +0300025EN rel. 1.5 - 17.02.2020 ENG pRack +0300025EN rel. 1.5 - 17.02.2020 4 ENG Content 1. INTRODUCTION 1.1 1.2 1.3 Main features ............................................................................................................................7 Components and accessories ........................................................................................7 Configuration of the system and configuration of the inputs .................... and outputs ...............................................................................................................................8 2. HARDWARE CHARACTERISTICS AND INSTALLATION 2.1 2.2 2.3 2.4 6. 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 27 Starting the first time ........................................................................................................ 27 5. USER INTERFACE 5.1 5.2 5.3 5.4 22 General installation instructions ................................................................................ 22 Power supply ......................................................................................................................... 22 Universal inputs/outputs................................................................................................ 22 Connecting the digital inputs ..................................................................................... 24 Connecting the analogue outputs .......................................................................... 25 Connecting the digital outputs.................................................................................. 25 pLAN electrical connections ........................................................................................ 26 4. START UP 4.1 9 pRack pR300 S, M, D, L board description ......................................................................9 Technical specifications ................................................................................................. 11 pRack pR300 S, M, D, L board dimensions.......................................................... 16 pRack pR300 general connection diagram ........................................................ 17 3. INSTALLATION 3.1 3.2 3.3 3.4 3.5 3.6 3.7 7 29 Graphic terminal .................................................................................................................. 29 Description of the display .............................................................................................. 29 Password ................................................................................................................................... 30 Description menu ............................................................................................................... 30 FUNCTIONS 32 Unit On-Off.............................................................................................................................. 32 Control ....................................................................................................................................... 32 Compressors........................................................................................................................... 35 Fans .............................................................................................................................................. 41 Energy saving ........................................................................................................................ 43 Accessory functions........................................................................................................... 44 Settings...................................................................................................................................... 49 Managing the default values ....................................................................................... 50 7. PARAMETERS TABLE 51 8. ALARMS 73 8.1 8.2 8.3 Alarm management .......................................................................................................... 73 Compressor alarms ............................................................................................................ 73 Pressure and prevent alarms ........................................................................................ 74 9. SUPERVISORY AND COMMISSIONING SYSTEMS 9.1 76 9.2 76 PlantVisor PRO, PlantWatch PRO, Boss and Boss-mini supervisory systems Commissioning software ............................................................................................... 76 10. UPDATING THE SOFTWARE 77 10.1 Update via pRack Manager /RHEC Manager ..................................................... 77 10.2 Updating using SmartKey.............................................................................................. 77 10.3 Pendrive: operating instructions ............................................................................... 77 10.4 Configuring pCOWeb/pCOnet from a system screen ................................ 80 10.5 Saving parameters between different software versions .......................... 81 11. APPENDIX 82 5 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG pRack +0300025EN rel. 1.5 - 17.02.2020 6 ENG 1. INTRODUCTION For each size the following versions are available: • with built-in terminal, without terminal 1.1 Main features pRack pR300 is the evolution of the pR100 electronic controller. The consolidated software for management of compressor racks is combined with new functions, on a totally upgraded hardware platform. Below are the main functions (new and consolidated) and compressor management features on pRack pR300. 1.1.1 All pRack pR300 models are equipped with: • integrated RS485 serial interface • anthracite gray plastic cover • connector kit • USB. pR300 functionality list pRack pR300 models Direct management via Fieldbus, using either the built-in driver (PRK300D*) or external driver, of one or two valves for the operation of heat exchangers typically used in subcritical systems (CO2) Code Description PRK300S0F0 pRack pR300 small, USB, no display, BMS/FBUS opto, connector kit, PRK300S0E0 pRack pR300 small, USB, no display, BMS/FBUS opto, 2 SSR, connector kit, PRK300M0F0 pRack pR300 medium, USB, no display, BMS/FBUS opto, connector kit, PRK300M0E0 pRack pR300 medium, USB, no display, BMS/FBUS opto, 2 SSR, connector kit, PRK300D0F0 pRack pR300 medium, EVD EVO embedded for 2 univ. EXV, USB, no display, BMS/FBUS opto, connector kit, PRK300D0E0 pRack pR300 medium, EVD EVO embedded for 2 univ. EXV, USB, no display, BMS/FBUS opto, 2 SSR, connector kit, PRK300L0F0 pRack pR300 large, USB, no display, BMS/FBUS opto, connector kit PRK300L0E0 pRack pR300 large, USB, no display, BMS/FBUS opto, 6 SSR, connector kit, PRK300S3F0 pRack pR300 small, USB, display built-in, BMS/FBUS opto, connector kit, PRK300S3E0 pRack pR300 small, USB, display built-in, BMS/FBUS opto, 2 SSR, connector kit, PRK300M3F0 pRack pR300 medium, USB, display built-in, BMS/FBUS opto, connector kit, PRK300M3E0 pRack pR300 medium, USB, display built-in, BMS/FBUS opto, 2 SSR, connector kit PRK300D3F0 pRack pR300 medium, EVD EVO embedded for 2 univ. exv, USB, display built-in, BMS/FBUS opto, connector kit PRK300D3E0 pRack pR300 medium, EVD EVO embedded for 2 univ. exv, USB, display built-in, bms/fbus opto, 2 SSR, connector kit PRK300L3F0 pRack pR300 large, USB, display built-in, BMS/FBUS opto, connector kit PRK300L3E0 pRack pR300 large, USB, display built-in, BMS/FBUS opto, 6 ssr, connector kit PRK300S3FK pRack pR300 small, USB, external display, BMS/FBUS opto, connector kit PRK300M3FK pRack pR300 medium, USB, external display, BMS/FBUS opto, connector kit PRK300D3FK pRack pR300 medium, EVD EVO embedded for 2 univ. EXV, USB, external display, BMS/FBUS opto, connector kit PRK300L3FK pRack pR300 large, USB, external display, BMS/FBUS opto, connector kit Up to 2 suction line and 2 condensing line Scroll, reciprocating, digital scroll and screw compressors management Up to 12 scroll compressors, reciprocating for line Main features Up to 2 screw compressors for line 1, maximum one screw compressors line Fino a 2 compressori Bitzer CRII (massimo 1 per linea) Up to 16 fans for line Inverter for suctione and condensing line Generic functions easily configurable (ON/OFF, modulations, alarms, scheduler) Heat recovery S, M, D, L version (based on pRack hardware) Hardware External display (pGDE) or built-in display Up to 12 piston compressors per line, a maximum of 4 different sizes Up to 4 alarms per compressor Compressors Inverter management, even with modulation inside the dead zone Pump down Control of overheating in suction Languages Italian, English, German, French, Spanish, Russian, Portoguese, Swedish Temperature: °C, °F Unit of Pressure: barg, psig (all pressure values are also converted to measure temperature) Date format settable between: dd/mm/yy, mm/dd/yy, yy.mm.dd Proportional band (P, PI) available for compressors and fans Control Neutral zone available for compressors and fans FIFO Compressor LIFO rotation Timed Fixed (the ON/OFF order can be set as required) Scheduling available: heating/cooling, 4 daily time bands, 5 special periods (e.g.: closing period), 10 special days (e.g.: holidays) Scheduling by Schedulable functions: set point compensation for compressors calendar and fans, split condenser (heating/cooling only), anti noise, heat recovery, generic functions Compensation from digital input, from scheduling, floating based Setpoint on supervisor parameter (compressors) or outside temperature (fans) Prevent High pressure, including activation of heat recovery or ChillBooster Automatic and manual management Configurable compressor alarms Alarms Double Signal on digital outputs for high or low priority alarms Log from application Supervisor Carel protocol Modbusâ Tab. 1.c Accessories: Tab. 1.a The pRack pR300 is available in 4 hardware sizes listed in the table (for the detailed description of each size, electrical characteristics and installation, refer to Chapter 2): Hardware sizes: Small Medium Medium + Driver Large Available ana- Available log inputs digital inputs 5 8 8 10 8 14 14 18 Available analog outputs 4 4 4 6 Description PGDERK0FX0 CONVONOFF0 pGD evolution user terminal for pRack pR300T Module to convert a 0...10 V analog output to an SPDT digital output RS485 serial connection board USB/RS485 serial convertor with telephone connector USB/RS485 serial converter with 3-way terminal Smart Key programming key Connection cable for terminal 1=0.8m Connection cable for terminal 1=1.5m Connection cable for terminal 1=3 m Ratiometric pressure probes 0…5 Vdc PCOS004850 CVSTDUTLF0 CVSTDUMOR0 PCOSO0AKY0 S90CONN002 S90CONN000 S90CONN001 SPKT*R* and SPKC00* SPK*C*, SPK1*, SPK2*, SPK3* NTC* NTC*HT* EVD0000E50 EVDIS00D*0 E2VCABS*00 1.2 Components and accessories Size Code Available digital outputs 8 13 13 18 Active pressure probes 4…20 mA Pressure probe NTC -50T90°C Pressure probe NTC -0T150°C EVD EVO universal driver for Carel valves, RS485/ModbusTM Display for EVD EVO EVD-valve connection cable Tab. 1.d Tab. 1.b 7 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Example 4: 2 suction lines on board (scroll or piston compressors), 2 high pressure lines on the board): 1.3 Configuration of the system and configuration of the inputs and outputs pRack pR300 has the same system, input and output configuration management as the standard pRack pR100. It is available 22 configurations, but it is more ultilised those described in Appendix A.1. I/O Note: each input/output is completely configurable with the only requirements being those set by the system configuration. For example, the suction pressure probe on line 1 can be arbitrarily configured to any one of the analog inputs in the pLAN control board with address 1 compatible with the type of probe. I/O pR300 Refer Cap. 4, to have more ionformation about selection of configuration system and pre-configuration and see Appendix A.1. I/O I/O System configurations available pRack pR300 can manage system configurations with up to 2 suction lines (maximum 12 scroll or piston compressors for lines 1 and 2, maximum 2 screw compressors for line 1 and maximum 1 BitzerCRII compressor per line), up to 2 condenser lines (maximum 16 fans per line). When there are two suction lines, the 2 lines can be managed by the same pRack board or by separate boards. The condenser lines can be managed by the board controls the suction lines or by separate boards, depending on the number of inputs/outputs available. For each suction and condenser line, pRack pR300 can manage a modulating device (inverter, Digital Scroll® compressor, compressor with continuous control or BitzerCRII compressor). pRack pR300 manages up to 1 line with screw compressors, and the board can control up to 2 compressors. Fig. 1.c Example 4: 2 suction lines on separate boards (scroll or piston compressors), 2 high pressure lines (on the first suction line board): I/O I/O 2 Example 1: 1 suction line with scroll or piston compressors, 1 high pressure line: C8 C7 C7 C4 3 2 NC8 NO8 C4 NO7 C1 NO6 NO5 NO4 C1 1 J26 FBus2 B M S card IDC1 ID8 ID7 ID6 ID4 Y4 ID3 ID2 ID1 Y3 Y1 VG0 VG GND U5 GND U4 +VDC J5 Y2 J4 J3 GND U3 U2 U1 G0 G J2 +5 VREF +Vterm J24 GND IDC1 ID8 ID7 ID6 ID5 ID4 Y4 ID3 ID2 ID1 Y3 J1 ID5 FieldBus card J5 Y2 Y1 VG0 VG GND U5 GND U4 +VDC J15 J14 4 B M S c ard J4 J3 GND U3 U2 U1 G0 G +5 VREF GND J2 J13 J25 BMS2 pR300 FieldBus card J24 NO3 J12 J11 pLAN J10 1 J26 FBus2 pR300 J1 NO2 J15 NO1 C8 C7 C7 3 NC8 C4 J14 4 J25 BMS2 NO8 C4 J13 J10 Some examples of managed system configurations are described below, while for the complete list of configurations and its features refer to Appendix A1. NO7 C1 NO6 NO5 C1 J12 J11 pLAN NO4 NO3 NO2 NO1 pLAN +Vterm 1.3.1 I/O I/O Fig. 1.d 4 3 2 C8 C7 Example 5: 2 suction lines on separate boards with scroll or piston compressors, 2 high pressure line on separate boar NC8 C7 C4 J10 J25 BMS2 NO8 NO7 C4 NO6 J14 J13 J15 1 J26 FBus2 pR300 I/O pLAN 4 J25 BMS2 3 2 3 2 C8 NC8 NO8 C7 NO7 C7 C4 NO6 NO5 NO4 C4 C1 J15 1 J26 FBus2 ID7 ID8 IDC1 C8 NC8 ID6 NO8 ID4 ID2 C4 ID3 ID1 NO6 Y2 C4 Y4 Y1 C1 Y3 VG0 NO3 NO5 VG J5 NO2 GND U5 GND U4 +VDC +5 VREF B M S c ard J4 J3 GND U2 J2 U1 G0 G IDC1 +Vterm ID8 C8 NC8 J24 GND ID7 NO8 ID6 ID5 ID4 ID3 ID2 ID1 Y4 Y3 J1 ID5 FieldBus card J5 Y2 Y1 VG0 VG GND U5 GND U4 +VDC NO3 4 B M S card J4 J3 GND U3 U2 U1 G0 +5 VREF G +Vterm GND J2 J14 J13 J25 BMS2 pR300 FieldBus card J24 NO2 J12 J11 pLAN J10 pR300 J1 NO1 C1 C8 NC8 C7 NO8 J15 1 J26 FBus2 U3 pLAN NO7 J14 J13 J10 I/O C7 C4 NO6 NO5 C4 J12 J11 pLAN NO4 C1 NO3 NO2 C1 IDC1 ID8 ID7 ID6 ID5 ID4 ID3 ID2 Y4 Y3 ID1 J5 Y2 Y1 VG0 VG GND U5 GND U4 +VDC I/O B M S card J4 J3 GND U3 U2 J2 U1 G0 +5 VREF G J24 GND +Vterm FieldBus card J1 NO1 J11 pLAN NO5 C1 J12 NO4 C1 NO3 NO2 NO1 I/O Fig. 1.a J11 pLAN 4 3 2 J12 J11 pLAN C7 NO7 C7 2 1 IDC1 ID8 ID7 ID6 ID5 ID4 ID3 ID2 ID1 Y4 Y3 J5 Y2 Y1 VG0 VG GND U5 GND U4 +VDC +5 VREF B M S card J4 J3 GND U3 U2 J2 U1 G0 G +Vterm J24 GND IDC1 ID8 ID7 J1 ID6 ID5 ID4 ID3 ID2 ID1 Y4 Y3 J5 Y2 Y1 VG0 VG GND U5 GND U4 +VDC FieldBus card B M S c ar d J4 J3 GND U3 U2 U1 +5 VREF G0 GND +Vterm G I/O J2 3 J26 FBus2 pR300 FieldBus card J24 NO4 4 J25 BMS2 J15 J14 J13 J10 1 J26 FBus2 pR300 J1 NO1 C1 J15 J14 J13 J10 J25 BMS2 C7 NO7 C7 C4 NO6 NO5 C4 J12 NO4 C1 NO3 NO2 C1 NO1 pLAN Example 2: 2 suction lines on the same board with scroll or piston compressors, 1 high pressure line: I/O I/O Fig. 1.e pR300 I/O Note: if connecting more than one pRack pR300 board in a pLAN, mixed networks cannot be created combining Compact boards and S, M, L boards, while mixed networks are possible using combinations of the latter models only. I/O Important: all the boards connected to the pLAN must have the same software revision. Fig. 1.b pRack +0300025EN rel. 1.5 - 17.02.2020 8 ENG 2. HARDWARE CHARACTERISTICS AND INSTALLATION 2.1 pRack pR300 S, M, D, L board description pRack pR300 S 14 C8 J15 J14 J13 J10 4 J25 BMS2 J26 FBus2 16 17 3 2 NC8 ID8 NO11 C7 NO8 ID7 NO10 C7 NO7 C4 NO6 C4 J12 J11 pLAN NO5 NO4 C1 C1 NO3 15 NO2 13 12 11 NO1 10 1 18 pR300 1 3 5 IDC1 8 7 6 ID6 ID4 ID3 ID2 ID1 Y4 Y3 Y2 Y1 VG0 VG GND U5 GND +VDC U4 3 4 J5 J4 J3 GND U3 U1 2 U2 J2 +5 VREF J24 GND G G0 +Vterm J1 B M S ca r d ID5 Fi eld Bus car d Fig. 2.a pRack pR300 M J10 4 J25 BMS2 J26 FBus2 16 17 3 2 C13 NC13 NO13 C12 NC12 NO12 C9 C8 C9 J17 J16 J15 J14 J13 NC8 NO8 C7 C7 NO7 C4 NO6 NO5 NO4 C4 C1 NO3 J12 J11 pLAN NO9 15 14 C1 13 NO2 12 11 NO1 10 J18 1 18 pR300 1 2 3 B M S card 3 5 6 7 8 ID14H ID14 IDC13 ID13 ID13H IDC9 J8 ID12 ID10 GND 3 ID9 U8 U7 U6 IDC1 ID8 ID7 8 ID11 J7 J6 ID6 ID5 ID4 ID3 ID2 Y4 ID1 Y3 Y2 Y1 VG0 VG GND U5 GND U4 +VDC 4 J5 J4 J3 GND U3 U2 J2 U1 +5 VREF J24 GND G0 G J1 +Vterm FieldBus car d 9 Fig. 2.b Legende: Rif. 1 Description Power supply connector [G(+), G0(-)] +Vterm: power supply for additional terminal 2 +5 VREF power supply for ratiometric probes 3 Universal inputs/outputs 4 +VDC: power supply for active probes 5 Button for setting pLAN address, second display, LED VG: power supply at voltage A(*) for opto-isolated analogue output 6 VG0: power to opto-isolated analogue output, 0 Vac/Vdc 7 Analogue outputs 8 ID: digital inputs for voltage A (*) ID..: digital inputs for voltage A (*) 9 IDH..: digital inputs for voltage B (**) 10 pLAN telephone connector for terminal/downloading application (*) Voltage A: 24 Vac or 28 to 36 Vdc; (**) Voltage B: 230 Vac - 50/60 Hz. Rif. 11 Description pLAN plug-in connector 12 Reserved 13 14 15 Reserved Reserved Relay digital outputs 16 BMS2 connector 17 18 FieldBus2 connector Jumpers for selecting FieldBus/ BMS Tab. 2.a 9 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG pRack pR300 D 14 J26FBus2 16 17 2 1 4 24 3 ID13 IDC13 ID14H S2 S3 ID13H DI2 S1 IDC9 DI1 VREF ID12 ID9 GND J7 S4 GND ID11 G G0 8 U8 U7 U6 IDC1 ID8 ID7 ID6 J6 ID14 J29 ID10 VBAT 7 6 ID5 ID4 ID3 Y4 ID2 ID1 Y3 Y2 Y1 VG0 VG GND 5 3 C13 23 C D A B J5 J4 U5 GND U4 +VDC GND 3 NO13 21 J30 B M S car d J3 U3 U1 U2 J2 +5 VREF GND +Vterm G0 G J24 2 20 18 22 J1 3 J28 4 1 J27 pR300 Field Bus car d NC13 C12 NC12 NO12 C9 NO11 NO10 C9 NO9 C8 1 2 2 J18 J17 4 3 1 4 J25 BMS2 3 J10 J16 J15 J14 J13 NC8 C7 NO8 C7 NO7 C4 NO6 NO5 C4 J12 J11 pLAN NO4 C1 C1 15 NO3 13 12 NO2 11 NO1 10 J8 9 8 Fig. 2.c Legende: Ref. 1 Description Power supply connector [G(+), G0(-)] +Vterm: power supply for additional terminal 2 +5 VREF power supply for ratiometric probes 3 Universal inputs/outputs 4 +VDC: power supply for active probes 5 Button for setting pLAN address, second display, LED VG: power supply at voltage A(*) for opto-isolated analogue output 6 VG0: power to opto-isolated analogue output, 0 Vac/Vdc 7 Analogue outputs 8 ID: digital inputs for voltage A (*) 9 ID..: digital inputs for voltage A (*); IDH..: digital inputs for voltage B (**) 10 pLAN telephone connector for terminal/downloading application 11 pLAN plug-in connector 12 Reserved (*) Voltage A: 24 Vac or 28 to 36 Vdc; (**) Voltage B: 230 Vac - 50/60 Hz. Ref. 13 Description Reserved 14 Reserved 15 16 17 Relay digital outputs BMS2 connector FieldBus2 connector 18 Jumpers for selecting FieldBus/ BMS 20 21 22 23 24 Electronic valve A connector Electronic valve B connector Connector for external Ultracap module (accessory) Valve driver analogue and digital inputs Valve status signal LED Tab. 2.b N.C. Model J18 C16 NO17 NO18 C16 NO16 C13 NC12 NO13 C12 NO12 C9 NO11 NO10 NO9 C9 C8 NO8 NC8 C15 1 NC15 2 J26 FBus2 J17 J16 NO15 3 C14 4 J15 NC14 J10 J25 BMS2 C7 C7 NO7 C4 NO6 NO5 J14 J13 NO14 J12 J11 pLAN NO4 C4 C1 NO3 C1 NO2 NO1 J22 NC13 15 C16 14 NC18 13 12 NC17 11 C16 10 NC16 pRack pR300 L J21 J22 J23 FBus2 15 15 19 17 18 9 3 7 N.O. Model 16 8 pR300 1 2 3 3 6 8 3 U10 GND ID17 IDC13 ID14 ID14H IDC17 GND ID13 ID18 U9 ID13H IDC9 ID12 ID11 ID10 ID9 GND U8 J6 U7 IDC1 U6 ID8 ID7 J7 ID6 ID5 ID4 Y6 Y5 ID16H ID16 IDC15 ID15 ID15H 7 ID3 ID2 ID1 Y4 Y3 Y2 Y1 VG0 VG GND 5 J20 J5 J4 U5 GND U4 +VDC 4 J19 B M S card J3 GND U3 U2 J2 U1 +5 VREF J24 GND G0 G J1 +Vterm FieldBus c ard 8 J8 9 Fig. 2.a Legende: Ref. Description 1 Power supply connector [G(+), G0(-)] +Vterm: power supply for additional terminal 2 +5 VREF power supply for ratiometric probes 5 Button for setting pLAN address, second display, LED VG: power supply at voltage A(*) for opto-isolated analogue output 6 VG0: power to opto-isolated analogue output, 0 Vac/Vdc 7 Analogue outputs 8 ID: digital inputs for voltage A (*) 9 ID..: digital inputs for voltage A (*); IDH..: digital inputs for voltage B (**) 10 pLAN telephone connector for terminal/downloading application (*) Voltage A: 24 Vac or 28 to 36 Vdc; (**) Voltage B: 230 Vac - 50/60 Hz. pRack +0300025EN rel. 1.5 - 17.02.2020 Ref. 11 Description pLAN plug-in connector 12, 13, 14 Reserved 15 Relay digital outputs 16 BMS2 connector 17 18 19 FieldBus2 connector Jumpers for selecting FieldBus/ BMS FieldBus2 connector Tab. 2.c 10 ENG 2.2 Technical specifications 2.2.1 Physical specifications Dimensions Plastic case Built-in terminal SMALL MEDIUM, LARGE, BUILT-IN DRIVER Assembly Material Flammability Ball pressure test Resistance to creeping current Colour PGD1 (132x64 pixel) with backlit keypad Operating conditions Storage conditions Ingress protection Environmental pollution Other features Class according to protection against electric shock PTI of the insulating materials Period of stress across the insulating parts Type of action Type of disconnection or microswitching Heat and fire resistance category Ageing characteristics (operating hours) Number of automatic operating cycles Overvoltage category 13 DIN modules 110 x 227,5 x 60 mm 18 DIN modules 110 x 315 x 60 mm 18 DIN modules 110 x 315 x 75 mm fitted on DIN rail in accordance with DIN 43880 CEI EN 50022 technopolymer V2 (UL94) and 850 °C (in accordance with IEC 60695) 125 °C ≥ 250 V White RAL 9016 PRK300*3**, PRK300*0**(w/o built-in terminal): -40T70 °C, 90% RH non-condensing(*) PRK300*3*0 (with built-in terminal): -20T60 °C, 90% RH non-condensing (*) with Ultracap module fitted: -40T60°C PRK300D*** (w/o built-in terminal): -40T70 °C, 90% RH non-condensing PRK300D*** (with built-in terminal): -30T70 °C, 90% RH non-condensing Models with USB port and/or with Ultracap module: IP20 on the front panel only Models without USB port and without Ultracap module: IP40 on the front panel only 2 to be integrated into Class I and/or II appliances in the versions without valve driver, class I in the versions with valve driver PCB: PTI 250 V; insulating material: PTI 175 long 1C; 1Y for SSR versions microswitching Category D (UL94-V2) 80,000 100,000 (EN 60730-1); 30,000 (UL 873) category II Tab. 2.d 2.2.2 Electrical specifications Power supply SMALL, MEDIUM, LARGE: use a dedicated 50 class II safety transformer VA. BUILT IN DRIVER: use a dedicated 100 VA class II safety transformer. Vac P (Vac) SMALL 24 Vac (+10/-15%), 45 VA MEDIUM 50/60 Hz protected LARGE by an external 2.5 A (EXTRALARGE) type T fuse Vdc P (Vdc) 28 to 36 Vdc 30 W (-20/+10%) protected by an external 2.5 A type T fuse BUILT-IN DRIVER 90 VA (DRIVER VALVE INTEGRATED) Important: only power “PRK300TD***” with alternating current. The power transformer secondary must be earthed. Not allowed Terminal block with male/female plug-in connectors Cable cross-section min 0.5 mm2 - max 2.5 mm2 CPU 32 bit, 100 MHz Non-volatile memory (FLASH) 2 M byte Bios + 11 Mbyte application program Data memory (RAM) 3.2 Mbyte (1.76 Mbyte Bios + 1.44 Mbyte application program) T buffer memory (EEPROM) 13 kbyte P parameter memory(EEPROM) 32 kbyte (not available to the pLAN) Clock with battery standard, precision 100 ppm Battery CR2430 3 Vdc lithium button battery (size 24x3 mm) Software class and structure Class A Category of immunity to voltage Category III surges (EN 61000-4-5) Device not designed to be hand-held when powered Tab. 2.e 11 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Universal inputs/outputs U... 4 - 0 to 5 V signals from ratiometric probes powered by controller Input precision: ± 0.3 % f.s. Time constant for each input: 0.5 s Classification of measuring circuits (CEI EN 61010-1): category I Digital inputs w/o optical isolation, Lmax = 30 m (maximum number) max tot 4 - 0 to 20 mA /4 to 20 mA inputs from probes powered by the controller - 0 to 20 mA /4 to 20 mA inputs powered externally 5 5 4 6 8 6 (max 4 on U1...U5, 3 on U6...U8) 7 (max 4 on U1...U5, 3 on U6...U8) 6 SMALL MEDIUM/ BUILT-IN DRIVER/EXTRALARGE 5 8 max 2 4 (max 2 on U1...U5, max 2 on U6...U8) - voltage-free contacts - fast digital inputs type: voltage-free contact max current: 10 mA max frequency 2kHz and resolution ±1 Hz max tot 10 - 0 to 1 Vdc/0 to 10 Vdc signals powered externally 5 max tot 9 - 0 to 1 Vdc/0 to 10 Vdc signals from probes powered by controller max tot 8 - CAREL NTC probes (-50T90°C; R/T 10 kΩ±1% at 25°C); - HT NTC (0T150°C); - PTC (600Ω to 2200Ω) - PT500 (-100T400°C) - PT1000 (-100T400°C) SMALL MEDIUM/ BUILT-IN LARGE DRIVER/EXTRALARGE 5 8 10 max tot 7 Analogue inputs, Lmax = 30 m (maximum number) max tot 5 2.2.3 6 10 6 (max 4 on U1...U5, 3 on U6...U8, 2 on U9...U10) 9 (max 4 on U1...U5, 3 on U6...U8, 2 on U9...U10) 6 LARGE 10 6 (max 2 on U1...U5, max 2 on U6...U8, 2 on U9...U10) Important: • for active probes powered externally (0 to 1 V, 0 to 10 V, 0 to 20 mA, 4 to 20 mA ), to avoid irreparably damaging the controller, implement adequate current protection measures that must ensure < 100 mA; • the ratiometric probes can only be powered by the controller; • on power-up, the universal inputs/outputs remain shorted to GND for around 500 ms until the end of the configuration procedure. Analogue outputs w/o optical isolation (maximum number), Lmax = 30 m 0 to 10 Vdc (maximum current 2 mA) PWM (output 0/3.3 Vdc, maximum current 2 mA, frequency: 2kHz asynchronous) SMALL MEDIUM/ BUILT-IN LARGE DRIVER/EXTRALARGE 5 8 10 5 8 10 Tab. 2.f 2.2.4 Power supply to probes and terminals can be used to power any active probes using the 24/21 Vdc ± 10% (P+5*/P+3*) available at terminal +VDC (J2). The maximum current available is 150 mA, protected against short-circuits. +5Vref to power the 0 to 5V ratiometric probes, use the 5 Vdc (± 5%) available at terminal +5VREF(J24). The maximum current available is 60 mA. P+3**********: 21 Vdc ± 10%; P+5**********: 24 Vdc ± 10% Vterm Used to power an external terminal as an alternative to the one connected to J10, Pmax = 1.5 W Important: if the length exceeds 10 m, use shielded cable with the shield connected to earth. In any case, the max length allowed is 30 m. +Vdc Tab. 2.g 2.2.5 Digital inputs ID... IDH... Type Lmax Optically-isolated 30 m Minimum digital input pulse detection time SMALL MEDIUM/ BUILT-IN DRIVER/EXTRALARGE LARGE Normally open (open-closed-open) Normally closed (closed-open-closed) Power supply to the inputs External Maximum number Classification of measuring Category I: 24 Vac/Vdc (J5, J7, J20) circuits (CEI EN 61010-1) Category III: 230 Vac (J8, J19) Digital input current draw at 24 Vac/Vdc Digital input current draw at 230 Vac no. of optically-isolated no. of optically-isolated inputs, 24 Vac/Vdc or 230 Vac inputs, 24 Vac or 24 Vdc - 50/60 Hz 8 None 12 2 14 4 200 ms 400 ms IDH...: 230 Vac (+10/-15%) 50/60 Hz ID...: 24 Vac (+10/-15%) 50/60 Hz o 28 to 36 Vdc (+10/-20%) 5 mA 5 mA Tab. 2.h Note: • separate as much as possible the probe and digital input cables from cables to inductive loads and power cables, so as to avoid possible electromagnetic disturbance. Never run power cables (including the electrical panel cables) and signal cables in the same conduits; • the two 230 Vac or 24 Vac/Vdc inputs on terminals J8 (ID13, ID14) or J19 (ID15, ID16) have the same common pole and therefore both will operate at 230 Vac or 24 Vac/Vdc. There is basic insulation between the two inputs; there is reinforced insulation between the inputs and the rest of the controller; • ID1...ID8, ID9 to ID12, ID17, ID18 have functional insulation from the rest of the controller; • for DC voltage inputs (24 Vdc) either the + or the - can be connected to common terminal; • the rating of the external contact connected to the digital inputs must be at least 5 mA. 2.2.6 Analogue outputs Y... pRack +0300025EN rel. 1.5 - 17.02.2020 12 ENG Type Lmax Maximum number Power supply Precision Resolution Settling time Maximum load 0 to 10 V optically-isolated on Y1...Y6 30 m SMALL, MEDIUM/ BUILT-IN DRIVER LARGE external Y1...Y6 8 bit Y1...Y6 1 kΩ (10 mA) 4 Y1...Y4, 0 to 10 V 6 Y1...Y6, 0 to 10 V 24 Vac (+10/-15%) or 28 to 36 Vdc on VG(+), VG0(-) ± 2% full scale from 1 s (slew rate 10 V/s) to 20 s (slew rate 0.5 V/s) selectable via SW Tab. 2.i Warnings: • for lengths > 10 m, only use shielded cable, with the shield connected to earth; • a 0 to 10 Vdc analogue output can be connected in parallel to other outputs of the same type, or alternatively to an external source of voltage. The higher voltage will be considered. Correct operation is not guaranteed if actuators with voltage inputs are connected; • power the VG-VG0 analogue outputs at the same voltage on G-G0: Connect G0 to VG0 and G to VG. This is valid for both alternating and direct current power supplies. 2.2.7 Digital outputs NO..., NC... Type Maximum no Relay. Minimum contact current: 50 mA. 8: SMALL; 13: MEDIUM/ BUILT-IN DRIVER; 18: LARGE; The relay outputs have different features depending on the model of controller. The outputs can be divided into groups. The relays belonging to the same group (individual cell in the table) have basic insulation and therefore must have the same voltage. Between groups (cells in the Insulation distance table) there is double insulation and consequently these may have different voltages. There is also double insulation between each terminal of the digital outputs and the rest of the controller. Relays with the same insulation Makeup of the groups Number of changeover contacts Model 1 SMALL 1...3 Type of relay Type A MEDIUM/ BUILT-IN DRIVER 1...3 Type of relay Type A LARGE NO 1...3 Type of relay Type A LARGE NC 1...3 Type of relay Type A 1: SMALL (relay 8) 3: MEDIUM (relay 8, 12, 13) 5: LARGE NO/NC (relay 8, 12, 13, 14 e 15) 2 3 4 5 Group 6 4...6 Type A 4...6 Type A 4...6 Type A 4...6 Type A 7 Type A 7 Type A 7 Type A 7 Type A 8 Type A 8 Type A 8 Type A 8 Type A 9...11 Type A 9...11 Type A 9...11 Type A 12 Type A 12 Type A 12 Type A 7 13 Type A 13 Type A 13 Type A 8 14...15 Type A 14...15 Type A 9 16...18 Type A 16...18 Type C 10 - 11 - Note: the output relays have different features, depending on the model of controller. Rated data Relay type A Approval Relay rated data Switchable power Relay type B Approval Relay rated data Relay type C Approval SPDT, 2000 VA, 250 Vac, 8A resistive UL 873 2 A 250 Vac resistive, 2A FLA, 12 LRA, 250 Vac, C300 pilot duty (30,000 cycles) EN 60730-1 2 A resistive, 2A inductive, cosφ=0.6, 2(2)A (100,000 cycles) SPST, 1250 VA, 250 Vac, 5A resistive UL 873 1 A 250 Vac resistive, 1A FLA, 6 LRA, 250 Vac, C300 pilot duty (30,000 cycles) EN 60730-1 1 A resistive, 1A inductive, cosφ=0.6, 1(1)A (100,000 cycles) SPDT, 1250 VA, 250 Vac, 5A resistive UL 873 1 A 250 Vac resistive, 1A FLA, 6 LRA, 250 Vac, C300 pilot duty (30,000 cycles) EN 60730-1 1 A resistive, 1A inductive, cosφ=0.6, 1(1)A (100,000 cycles) Tab. 2.a 2.2.8 SSR outputs (in models where featured) Maximum number Working voltage Load current (MAX) Impulsive load current (MAX) 2: SMALL (ouputs 7, 8); 2: MEDIUM (ouputs 7, 12); 6: LARGE (ouputs 7, 8, 12, 13, 14, 15) 24 Vac/Vdc 1A 1.2 A Tab. 2.j Warnings: • if the load requires higher current, use an external SSR; • to power external resistive loads via SSRs, use the same power supply as the pRack (supplied to terminals G-G0), which must be dedicated and not shared by other devices (contactors, coils, etc..); • the groups that the digital outputs are divided into have two common pole terminals to simplify wiring; • make sure that the current running through the common terminals does not exceed the rated current of an individual terminal, that is, 8 A. 13 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG 2.2.9 Serial port Use AWG20/22 shielded three-wire cable (one twisted pair plus a third wire) with a capacitance between the wires of less than 90 pF/m (example: BELDEN 3106A). The shield must be connected to earth and not to the GND terminals. Alternatively, use AWG20/22 shielded twisted pair cable with a capacitance between the wires of less than 90 pF/m (example: BELDEN 8761); use the shield to connect the GND terminals, without connecting it to earth. The maximum length of the serial network is 500 m with AWG22 cable, 1000 m with AWG20 cable. Serial Serial ZERO Type/connectors pLAN/J10, J11 Serial ONE BMS 1 Serial Card Serial TWO FieldBus 1 Serial Card Serial THREE BMS 2 / J25 Serial FOUR FFieldBus 2 / J26 (and J23 on Large and Extralarge version) Features • • • • • • • • • • • • • • • • • • • • • • • • Integrated on main board HW driver: asynchronous half duplex RS485 pLAN Not optically-isolated Connectors: 6-pin telephone jack + 3-pin plug-in p. 5.08 Maximum length: 500 m Max data rate: 115200 bit/s Maximum number of connectable devices: 3 Not integrated on main board HW driver: not featured Can be used with all pRack family optional BMS cards Not integrated on main board HW driver: not present Can be used with all pRack family optional FieldBus cards Integrated on main board HW driver: asynchronous half duplex RS485 Slave Optically-isolated 3-pin plug-in connector p. 5.08 Maximum length: 1000 m Max data rate: 384000 bit/s Integrated on main board J23: not optically-isolated J26: optically-isolated 3-pin plug-in connector p. 5.08 J23 and J26 are independent. Tab. 2.k Note: in industrial/residential environments, for distances > 10 m, shielded cable is required, with the shield connected to earth. In residential environments (EN 55014), irrespective of the cable length, on versions without valve driver, the connection cable between the controller and the terminal and the serial cable must be shielded and connected to earth at both ends. 2.2.10 Model with electronic expansion valve driver Valve compatibility Motor connection Digital input connection Sonde CAREL: E*V**** ALCO: EX4; EX5; EX6; EX7; EX8 330 Hz (recommended by CAREL); EX8 500 Hz (from ALCO specifications) SPORLAN: SEI 0.5-11; SER 1.5-20; SEI 30; SEI 50; SEH 100; SEH175 Danfoss: ETS 12.5-25B; ETS 50B; ETS 100B; ETS 250; ETS 400 CCM 40, CCM 10-20-30, CCMT 2-4-8 CAREL: two CAREL EXV as for EVD EVOLUTION TWIN SPORLAN: SER(I) G, J, K Shielded 4-wire cable CAREL P/N E2VCABS*00, or AWG22 shielded 4-wire cable Lmax =10 m, or AWG14 shielded 4-wire cable Lmax 50 m Digital input to be activated with voltage-free contact or transistor to GND. Closing current 5mA; maximum length < 10 m Maximum length 10 m or less than 30 m with shielded cable S1 ratiometric pressure probe (0 to 5 V) electronic pressure sensor (4 to 20 mA) combined ratiometric pressure probe (0 to 5 V) 4 to 20 mA input (max. 24 mA) S2 low temperature NTC high temperature NTC resolution 0.1 % fs resolution 0.5 % fs resolution 0.1 % fs resolution 0.5 % fs 10 kΩ at 25 °C, -50T90 °C 50 kΩ at 25 °C,-40T150 °C combined NTC 0 to 10 V input (max 12 V) S3 ratiometric pressure probe (0 to 5 V): electronic pressure sensor (4 to 20 mA) combined ratiometric pressure probe (0 to 5 V) 4 to 20 mA input (max. 24 mA) S4 low temperature NTC high temperature NTC 10 kΩ at 25 °C,-40T120 °C resolution 0.1 % fs resolution 0.1 % fs resolution 0.5 % fs resolution 0.1 % fs resolution 0.5 % fs 10 kΩ at 25 °C,-50T105 °C 10 kΩ at 25 °C,-40T150 °C combined NTC Power to active probes (VREF) Emergency power supply 10 kΩ at 25 °C, -40T120 °C measurement error: 2% fs maximum; 1% typical measurement error: 8% fs maximum; 7% typical measurement error: 2 % fs maximum; 1 % typical measurement error: 8 % fs maximum; 7 % typical measurement error: 1°C in the range -50T50 °C; 3°C in the range +50T90 °C measurement error: 1.5 °C in the range -20T115°C, 4 °C in range outside of -20T115 °C measurement error: 1°C in the range -40T50 °C; 3°C in the range +50T90 °C measurement error: 9% fs maximum; 8% typical measurement error: 2% fs maximum; 1% typical measurement error: 8% fs maximum; 7% typical measurement error: 2 % fs maximum; 1 % typical measurement error: 8 % fs maximum; 7 % typical measurement error: 1 °C in the range -50T50 °C; 3°C in the range 50T90 °C measurement error: 1.5 °C in the range -20T115 °C; 4 °C in range outside of -20T115 °C measurement error 1 °C in the range -40T50 °C; 3°C in the range +50T90 °C programmable output: +5 Vdc ±2% or 12 Vdc ±10%, Imax = 50 mA optional Ultracapacitor module (PCOS00UC20 or EVD0000UC0). If the controller operates constantly at temperatures near the upper limit of 60°C it’s recommended to use the external module EVD0000UC0, where possible located in the coolest point of the panel. The PCOS00UC20 and EVD0000UC0 modules can be connected at the same time to the same controller, thus doubling the energy available to close the valves. Important: The module only powers the valve driver and not the controller. Tab. 2.l pRack +0300025EN rel. 1.5 - 17.02.2020 14 ENG 2.2.11 Meaning of the inputs/outputs on the pRack pR300 S, M, L boards Version S, M, L M, L S, M, L M, L L Connector J1-1 J1-2 J2-1 J2-2 J2-3 J2-4 J2-5 J3-1 J3-2 J3-3 J3-4 J4-1 J4-2 J4-3 J4-4 J4-5 J4-6 J5-1 J5-2 J5-3 J5-4 J5-5 J5-6 J5-7 J5-8 J5-9 J6-1 J6-2 J6-3 J6-4 J7-1 J7-2 J7-3 J7-4 J7-5 J8-1 J8-2 J8-3 J8-4 J8-5 J9 J10 J11-1 J11-2 J11-3 J12-1 J12-2 J12-3 J12-4 J12-5 J13-1 J13-2 J13-3 J13-4 J13-5 J14-1 J14-2 J14-3 J15-1 J15-2 J15-3 J16-1 J16-2 J16-3 J16-4 J16-5 J17-1 J17-2 J17-3 J18-1 J18-2 J18-3 J19-1 J19-2 J19-3 J19-4 J19-5 J20-1 J20-2 J20-3 J20-4 J20-5 Signal G G0 B1 B2 B3 GND +VDC B4 BC4 B5 BC5 VG VG0 Y1 Y2 Y3 Y4 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 IDC1 B6 B7 B8 GND ID9 ID10 ID11 ID12 IDC9 ID13H ID13 IDC13 ID14 ID14H RX-/TXRX+/TX+ GND C1 NO1 NO2 NO3 C1 C4 NO4 NO5 NO6 C4 C7 NO7 C7 NO8 C8 NC8/--C9 NO9 NO10 NO11 C9 NO12 C12 NC12/--NO13 C13 NC13 ID15H ID15 IDC15 ID16 ID16H Y5 Y6 B9 BC9 B10 Description +24 Vdc or 24 Vac power supply power supply reference universal analogue input 1 (NTC, 0 to 1 V, 0 to 5 V ratiometric, 0…10 V, 0…20 mA, 4…20 mA) universal analogue input 2 (NTC, 0 to 1 V, 0 to 5 V ratiometric, 0…10 V, 0…20 mA, 4…20 mA) universal analogue input 3 (NTC, 0 to 1 V, 0 to 5 V ratiometric, 0…10 V, 0…20 mA, 4…20 mA) common for analogue inputs 21 Vdc power supply for active probes (maximum current 200 mA) passive analogue input 4 (NTC, PT1000, ON/OFF) common for analogue input 4 passive analogue input 5 (NTC, PT1000, ON/OFF) common for analogue input 5 power to optically-isolated analogue output, 24 Vac/Vdc power to optically-isolated analogue output, 0 Vac/Vdc analogue output no. 1, 0…10 V analogue output no. 2, 0…10 V analogue output no. 3, 0…10 V analogue output no. 4, 0…10 V digital input no. 1, 24 Vac/Vdc digital input no. 2, 24 Vac/Vdc digital input no. 3, 24 Vac/Vdc digital input no. 4, 24 Vac/Vdc digital input no. 5, 24 Vac/Vdc digital input no. 6, 24 Vac/Vdc digital input no. 7, 24 Vac/Vdc digital input no. 8, 24 Vac/Vdc common for digital inputs from 1 to 8 (negative pole for DC power supply) universal analogue input 6 (NTC, 0 to 1 V, 0 to 5 V ratiometric, 0…10 V, 0…20 mA, 4…20 mA) universal analogue input 7 (NTC, 0 to 1 V, 0 to 5 V ratiometric, 0…10 V, 0…20 mA, 4…20 mA) universal analogue input 8 (NTC, 0 to 1 V, 0 to 5 V ratiometric, 0…10 V, 0…20 mA, 4…20 mA) common for analogue inputs digital input no. 9, 24 Vac/Vdc digital input no. 10, 24 Vac/Vdc digital input no. 11, 24 Vac/Vdc digital input no. 12, 24 Vac/Vdc common for digital inputs from 9 to 12 (negative pole for DC power supply) digital input no. 13, 230 Vac digital input no. 13, 24 Vac/Vdc common for digital inputs 13 and 14 (negative pole for DC power supply) digital input no. 14, 24 Vac/Vdc digital input no. 14, 230 Vac 8-pin telephone connector for connecting a display terminal (not used) 6-pin telephone connector for connecting the standard pGDE user terminal RX-/TX- connector for RS485 connection to the pLAN network RX+/TX+ connector for RS485 connection to the pLAN network GND connector for RS485 connection to the pLAN network common for relays: 1, 2, 3 normally open contact, relay no. 1 normally open contact, relay no. 2 normally open contact, relay no. 3 common for relays: 1, 2, 3 common for relays: 4, 5, 6 normally open contact, relay no. 4 normally open contact, relay no. 5 normally open contact, relay no. 6 common for relays: 4, 5, 6 common for relay no. 7 normally open contact, relay no. 7/ normally open contact, relay no. 7 SSR 24 Vac/Vdc (*) common for relay no. 7 normally open contact, relay no. 8/ only S-board: normally open contact, relay no. 8 SSR 24 Vac/Vdc, S board only (*) common for relay no. 8 normally closed contact relay no. 8/ only S-board: not used, S board only (*) common for relay: 9, 10, 11 normally open contact, relay no. 9 normally open contact, relay no. 10 normally open contact, relay no. 11 common for relay: 9, 10, 11 normally open contact, relay no. 12/ normally open contact, relay no. 12 SSR 24 Vac/Vdc (*) common for relay no. 12 normally closed contact relay no. 12/ not used (*) normally open contact, relay no. 13 / normally open contact, relay no. 13 SSR 24 Vac/Vdc (*) common for relay no. 13 normally closed contact relay no. 13 / not used (*) digital input no. 15, 230 Vac digital input no. 15, 24 Vac/Vdc common for digital inputs 15 and 16 (negative pole for DC power supply) digital input no. 16, 24 Vac/Vdc digital input no. 16, 230 Vac digital input no. 5 0…10 V digital input no. 6 0…10 V passive analogue input 9 (NTC, PT1000, ON/OFF) common for analogue input 9 passive analogue input 10 (NTC, PT1000, ON/OFF) 15 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Version Connector J20-6 J20-7 J20-8 J20-9 J21-1 J21-2 J21-3 J21-4 J21-5 L J21-6 J22-1 J22-2 J22-3 J22-4 J22-5 J23-1 J23-2 J23-3 J23-1 L J23-2 J23-3 J24-1 J24-2 J24-3 J25-1 J25-2 S, M, L, D J25-3 J26-1 J26-2 J26-3 J27-1 J27-2 J27-3 J27-4 J28-1 J28-2 J28-3 J28-4 J29-1 J29-2 D J29-3 J29-4 J29-5 J29-6 J29-7 J29-8 J30-1 J30-2 J30-3 (*) depending on model Signal BC10 ID17 ID18 IDC17 NO14 C14 NC14/--NO15 C15 NC15/--C16 NO16 NO17 NO18 C16 EE+ GND EE+ GND +V term GND +5 Vref EE+ GND EE+ GND 1 2 3 4 1 2 3 4 GND VREF S1 S2 S3 S4 DI1 DI2 VBAT G0 G Description common for analogue input 10 digital input no. 17, 24 Vac/Vdc digital input no. 18, 24 Vac/Vdc common for digital inputs 17 and 18 (negative pole for DC power supply) normally open contact, Relais no. 14/ normally open contact, Relais no. 14 SSR 24 Vac/Vdc (*) common for Relais no. 14 normally closed contact Relais no. 14/ not used (*) normally open contact, Relais no. 15/ normally open contact, Relais no. 15 SSR 24 Vac/Vdc (*) common for Relais no. 15 normally closed contact Relais no. 15/ not used (*) common for Relais: no. 16, 17, 18 normally open contact, Relais no. 16 normally open contact, Relais no. 17 normally open contact, Relais no.18 common for Relais: no. 16, 17, 18 E- terminal for RS485 connection to the I/O expansion modules (not used) E+ terminal for RS485 connection to the I/O expansion modules (not used) GND terminal for RS485 connection to the I/O expansion modules (not used) E- terminal for RS485 connection to the I/O expansion modules (not used) E+ terminal for RS485 connection to the I/O expansion modules (not used) GND terminal for RS485 connection to the I/O expansion modules (not used) additional power supply terminal Aria (not used) power supply common power supply for 0/5 V ratiometric probes E- terminal for RS485, BMS2 connection E+ terminal for RS485, BMS2 connection GND terminal for RS485, BMS2 connection E- terminal for RS485, FIELDBUS 2 connection E+ terminal for RS485, FIELDBUS 2 connection GND terminal for RS485, FIELDBUS 2 connection ExV connection, stepper motor power supply ExV connection, stepper motor power supply ExV connection, stepper motor power supply ExV connection, stepper motor power supply ExV connection, stepper motor power supply ExV connection, stepper motor power supply ExV connection, stepper motor power supply ExV connection, stepper motor power supply Earth for the signals Active probe power supply Probe 1 (pressure) or external signal 4…20mA Probe 2 (temperature) or external signal 0…10V Probe 3 (pressure) or external signal 4…20mA Probe 4 (temperature) Digital input 1 Digital input 2 Emergency power supply Electrical power supply Electrical power supply Tab. 2.m 2.3 pRack pR300 S, M, D, L board dimensions 45 110 44 pR300 B A Fig. 2.d A B B - with USB port and/or built-in terminal B - with Ultracap module Small 227,5 60 70 - Medium 315 60 70 - Buit-in driver 315 60 70 75 Large 315 60 70 - Tab. 2.n pRack +0300025EN rel. 1.5 - 17.02.2020 16 ENG 2.4 pRack pR300 general connection diagram Small 24 Vac/230 Vdc 0 Vac/Vdc 24 Vac/230 Vac 0 Vac/Vdc 24 Vac/230 Vac 0 Vac/Vdc J10 4 3 2 C8 NC8 C7 NO8 C7 J14 J13 J25 BMS2 NO7 C4 NO6 NO5 J15 1 J26 FBus2 GND + pR300 - C4 J12 J11 pLAN NO4 C1 NO3 NO2 C1 NO1 24 Vac/230 Vac 0 Vac/Vdc pGDE pRack RS485 BMS connections White IDC1 ID GND U5 U4 GND J3 +VDC GND U1 White Green U3 U2 GND U3 U2 U1 Black ID8 ID7 ID6 ID5 ID4 ID3 ID2 Y4 ID1 Y3 Y1 VG0 VG GND U5 GND U4 +VDC +VDC GND U3 U2 4-20 mA Probe: Ratiometric probe: J2 U1 J5 Y2 J4 J3 GND U3 U1 GND Ntc/Pt1000 U2 J2 +5 VREF J24 B M S car d +VDC 24 Vac/Vdc 0 Vac/Vdc G0 G J1 +Vterm Fi eld Bus car d Black Green (max 6 active probes) Universal inputs U1-U2-U3-U4-U5 (*) *NOT USED Refer to technical leaflet to different 4 -20 mA sensors model ID 24 Vac/Vdc 0 Vac/Vdc 17 OUT 4 OUT 1 OUT 2 OUT 3 AO/DO 24 Vac/ Vdc 0 Vac/Vdc pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Medium 24 Vac/230 Vdc 0 Vac/Vdc 24 Vac/230 Vac 0 Vac/Vdc 24 Vac/230 Vac 0 Vac/Vdc J10 4 3 2 C13 NC13 NO13 C12 J17 J16 J15 NC12 NO12 C9 NO11 NO10 C9 NO9 C8 NC8 C7 NO8 C7 J14 J13 J25 BMS2 NO7 C4 NO6 NO5 J18 1 J26 FBus2 GND + pR300 - C4 J12 J11 pLAN NO4 C1 NO3 NO2 C1 NO1 pGDE pRack RS485 BMS connections ID White GND U5 GND J3 U4 +VDC GND U3 U2 4-20 mA Probe: Green ID14H ID14 IDC13 ID13 ID13H IDC9 J8 ID12 ID11 ID10 ID9 GND U8 U7 U6 IDC1 J6 U1 GND U3 U2 Black White ID8 ID7 J7 ID6 ID5 ID4 ID3 ID2 Y4 ID1 Y3 Y2 VG0 VG U5 GND U4 +VDC GND U1 +VDC GND U3 U2 J5 Ratiometric Probe: J2 U1 Y1 J4 J3 GND U3 U1 GND Ntc/Pt1000 U2 J2 +5 VREF J24 B M S card +VDC 24 Vac/Vdc Vac V ac/V /Vdc dc 0 Vac/Vdc Vac/ Va c/Vd c/ Vdcc Vd G0 G J1 +Vterm Fi eldBus card Black Green (* ) *NOT USED Refer to technical leaflet to different 4 -20 mA sensors model or 24 Vac/Vdc 24 Vac/Vdc 0 Vac/Vdc pRack +0300025EN rel. 1.5 - 17.02.2020 18 0 Vac/Vdc 230 Vac 0 Vac/Vdc ENG Large 24 Vac/230 Vac 0 Vac/Vdc C13 C16 NO18 NO17 NO16 NC13 NO13 NC12 C12 NO12 C9 NO11 NO10 C9 C16 - U10 GND ID17 IDC13 ID14 ID14H IDC17 GND ID13 ID18 U9 Y6 ID13H Y5 ID16H ID16 ID15 ID15H IDC15 GND + IDC9 ID12 ID11 ID10 GND U4 U5 J3 +VDC GND U3 U1 U2 Bianco Verde J8 ID GND ID9 GND U8 U7 U6 IDC1 ID8 ID7 ID6 J6 Sonda 4-20 mA: +VDC GND U3 U2 Bianco J20 J7 ID5 ID4 ID3 ID2 Y4 ID1 Y3 Y2 VG0 VG GND U5 GND Nero Verde (*) ID18 ID17 GND U10 GND U9 Y6 Y5 J20 IDC17 *NON USATO Per altri tipi di sensori 4 -20 mA fare riferimento al relativo foglio di istruzioni or 24 Vac/Vdc ID17 ID18 GND U10 GND U9 Y6 Y5 J20 IDC17 24 Vac/Vdc 0 Vac/Vdc 230 Vac 0 Vac/Vdc 0 Vac/Vdc 0 Vac/Vdc OUT 5 OUT 6 +VDC U4 U1 GND U3 +VDC Nero J19 J5 Sonda raziometrica: J2 U2 Y1 J4 J3 GND U3 U2 U1 GND +5 VREF +Vterm J2 Ntc/Pt1000 U1 G0 G 24 Vac/Vdc 0 Vac/Vdc J24 B M S car d J18 J23 FBus2 J22 RS485 BMS connections J1 NO9 C8 NC8 J21 J26 FBus2 pR300 FieldBus card NC15 1 J17 J16 C15 2 NC14 3 J15 NO15 C7 NO8 C7 4 C14 J10 J25 BMS2 NO7 J14 J13 NO14 J12 J11 pLAN C4 NO6 C1 NO3 NO2 C1 NO1 24 Vac/230 Vac 0 Vac/Vdc pGDE pRack 19 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Built-in Driver CAREL ExV valve A pGDE pRack verde/green marrone/brown giallo/yellow bianco/white verde/green marrone/brown giallo/yellow bianco/white CAREL ExV valve B shield 3 2 Bianco NC13 C13 NO13 NC12 C12 NO12 C9 NO11 NO10 C9 DI2 DI1 ID GND U5 U4 GND J3 +VDC GND U3 U2 U1 Bianco Verde ID14H ID14 IDC13 ID13 IDC9 ID13H J8 ID12 ID11 ID10 ID9 S4 S3 S2 S1 VREF GND G0 VBAT G GND U8 U7 U6 IDC1 ID8 J6 4-20 mA Probe: +VDC GND U3 U2 U1 Nero NO9 C8 - GND + ID7 ID6 J7 ID5 ID4 ID3 ID2 Y4 ID1 Y3 Y1 VG0 VG GND U5 GND U4 +VDC +VDC GND U3 U2 U1 J2 J29 C D A B J5 Y2 J4 Ratiometric probe: Ntc/Pt1000 J28 J30 B M S c ar d J3 GND U3 U1 GND U2 J2 +5 VREF +Vterm G0 G 24 Vac/Vdc 0 Vac/Vdc J24 J27 1 RS485 BMS connections J1 J18 J26 FBus2 pR300 FieldBus card J17 J16 1 3 2 4 4 J15 1 3 2 4 J10 NC8 C7 NO8 C7 J14 J13 J25 BMS2 NO7 C4 NO6 NO5 C4 J12 J11 pLAN NO4 C1 NO3 NO2 C1 NO1 shield Nero Verde (*) *NOT USED Refer to technical leaflet to different 4 -20 mA sensors model Connection with other different valve model Key: 3 3 4 COMA NOA 1 green 2 brown 2 4 5 2 6 1 4 3 white 4 red pRack +0300025EN rel. 1.5 - 17.02.2020 3 5 5 5 black 6 blue 20 ratiometric pressure transducer driver B NTC driver B 1 1 3 ALCO EX5/6 EX7/8 DANFOSS ETS/CCM/CCMT NTC driver A Sporlan SEI / SEH / SER ratiometric pressure transducer driver A G G0 VBAT DI1 S4 S3 S2 S1 VREF GND J29 ENG External Driver (suitable for S/M/L/D) C8 J10 4 3 2 NC8 - C7 NO8 J15 J14 J13 J25 BMS2 GND + C7 NO7 C4 NO6 NO5 C4 J12 J11 pLAN NO4 C1 NO3 NO2 C1 NO1 pGDE pRack 1 J26 FBus2 pR300 RS485 BMS connections B M S ca rd IDC1 ID8 ID7 ID6 ID5 ID4 ID3 ID2 Y4 ID1 Y3 Y1 VG0 VG GND U5 GND U4 +VDC GND 230 Vac J5 Y2 J4 J3 U3 U1 U2 J2 +5 VREF J24 GND 24 Vac 35 VA TRADRFE240 (dedicated) shield 4 198 serial address 2 NOA 3 COMA 1 DI1 DI2 G G0 VBAT G0 VBAT G 2 AT S4 G0 G J1 +Vterm Field Bus card S3 S1 VREF S2 GND Ultracap Technology GND Tx/Rx Connection with other different valve model 1 1 3 Key: 3 3 4 COMA NOA 1 green 2 brown 2 4 5 2 6 1 4 3 white 4 red ALCO EX5/6 EX7/8 DANFOSS ETS/CCM/CCMT 3 5 5 5 black 6 blue 21 NTC driver A ratiometric pressure transducer driver B NTC driver B Sporlan SEI / SEH / SER ratiometric pressure transducer driver A G G0 VBAT pRack +0300025EN rel. 1.5 - 17.02.2020 ENG 3. INSTALLATION • in residential environments, the connection cable between the pRack 3.1 General installation instructions 3.1.1 pR300 and the terminal must be shielded; • there is no limit to the number of cables that can be connected to an Installation procedure individual terminal. The only limitation concerns the maximum current crossing each terminal: this must not exceed 8 A; • the maximum cross-section of the cable that connected to a terminal is 2.5 mm2 (12 AWG); • the maximum value of the twisting torque to tighten the screw on the terminal (torque tightening) is 0.6 Nm; Environmental conditions Avoid assembling the pRack pR300 and the terminal in environments with the following characteristics: • temperature and humidity that do not conform to the rated operating data of the product; • strong vibrations or knocks; • exposure to aggressive and polluting atmospheres(e.g.: sulphur and • • • • • Important: • Installation must be performed according to the standards and ammonia fumes, saline mist, smoke) so as to avoid corrosion and/or oxidation; strong magnetic and/or radio frequency interference (therefore avoid installing the units near transmitting antennae); exposure of the pRack pR300 to direct sunlight and to the elements in general; large and rapid fluctuations in the room temperature; environments containing explosives or mixes of flammable gases; exposure to dust (formation of corrosive patina with possible oxidation and reduction of insulation). legislation in force in the country where the device is used; • for safety reasons the equipment must be housed inside an electrical panel, so that the only accessible part is the display and the keypad; • in the event of malfunctions, do not attempt to repair the device, but rather contact the CAREL service centre; • the connector kit also contains the stick-on labels. 3.1.3 Positioning the instrument inside the panel The position of the instrument in the electrical cabinet must be chosen so as to guarantee correct physical separation of the instrument from the power components (solenoids, contactors, actuators, inverters, …) and the connected cables. Proximity to such devices/cables may create random malfunctions that are not immediately evident. The structure of the panel must allow the correct flow of cooling air. 3.1.2 3.2 Power supply Power supply to the pRack pR300 S, M; L (controller with terminal connected) Power supply to the pRack pR300 Compact Wiring procedure When laying the wiring, “physically “ separate the power part from the control part. The proximity of these two sets of wires will, in most cases, cause problems of induced disturbance or, over time, malfunctions or damage to the components. The ideal solution is to house these two circuits in two separate cabinets. Sometimes this is not possible, and therefore the power part and the control part must be installed inside the same panel. For the control Signals, it is recommended to use shielded cables with twisted wires. • • • • • • Important: controller using a class 2 safety transformer - 100 VA for the models with built-in driver, and 50 VA for the pRack S, M, L models; • the power supply to the pRack pR300 controller and terminal (or pRack pR300 controllers and terminals) should be separated from the power supply to the other electrical devices (contactors and other electromechanical components) inside the electrical panel; • if the power transformer secondary is earthed, check that the earth wire corresponds to the wire that runs to the controller and enters terminal G0. This applies to all the devices connected to the pRack pR300; • a yellow LED indicates that power is connected to the pRack pR300. each screw and insert the cable ends, then tighten the screws. When the operation is completed, slightly tug the cables to check they are sufficiently tight; separate as much as possible the sensor Signal, digital input and serial line cables from the cables carrying inductive loads and power cables to avoid possible electromagnetic disturbance. Never insert power cables (including the electrical cables) and probe Signal cables in the same conduits. Do not install the sensor cables in the immediate vicinity of power devices (contactors, circuit breakers or similar); reduce the path of the sensor cables as much as possible, and avoid spiral paths that enclose power devices; avoid touching or nearly touching the electronic components fitted on the boards to avoid electrostatic discharges (extremely damaging) from the operator to the components; if the power transformer secondary is earthed, check that the earth wire corresponds to the wire that runs to the controller and enters terminal G0; this applies to all the devices connected to the pRack pR300; do not secure the cables to the terminals by pressing the screwdriver with excessive force, to avoid damaging the pRack pR300; for applications subject to considerable vibrations (1.5 mm pk-pk 10/55 Hz), secure the cables connected to the pRack pR300around 3 cm from the connectors using clamps; if the product is installed in industrial environments (application of the EN 61000-6-2 standard) the length of the connections must be less than 30 m; all the very low voltage connections (analogue and 24 Vac/Vdc digital inputs, analogue outputs, serial bus connections, power supplies) must have reinforced or double insulation from the mains network; pRack +0300025EN rel. 1.5 - 17.02.2020 DC power supply: 48 Vdc (36 Vmin…72 Vmax) AC power supply: 24 Vac +10/-15 %, 50/60 Hz Maximum current P=11W, P=14VA, Imax=700mA • power supplies other than those specified seriously damage the system; • in the installation, it is recommended to supply just one pRack pR300 • Use cable ends suitable for the corresponding terminals. Loosen • 28…36 Vdc +10/-20% or24 Vac +10/-15% 50…60 Hz; Maximum current P= 15 W (power supply Vdc). P=40 VA (Vac) Tab. 3.a If the control cables have to cross over the power cables, the intersections must be as near as possible to 90 degrees, always avoiding running the control cables parallel to the power cables. • Anchoring the pRack pR300 The pRack pR300is installed on a DIN rail. To fasten the unit to the DIN rail, press it lightly against the rail. The rear tabs will click into place, locking the unit to the rail. Removing the unit is just as Simple, using a screwdriver through the release slot to lever and lift the tabs. The tabs are kept in the locked position by springs. 3.3 Universal inputs/outputs Universal inputs/outputs are distinguished by the letter U... They can be configured from the application program for many different uses, such as the following: • passive temperature probes: NTC, PTC, PT500, PT1000; • active pressure/temperature/humidity probes; • ratiometric pressure probes; • current inputs, 0 to 20 mA or 4 to 20 mA; • voltage inputs, 0 to 1 Vdc or 0 to 10 Vdc; • voltage-free contact digital inputs and fast digital inputs; • analogue outputs, 0 to 10 Vdc; • PWM outputs. Important: • the universal inputs/outputs cannot be used as digital outputs. 22 ENG Max. number of connectable analogue inputs 3.3.2 The maximum number of analogue inputs that can be connected to the universal inputs/outputs depends on the type used. For information on the maximum number of probes that can be connected see the table at the beginning of this paragraph. The pRack pR300 can be connected to 2-wire PT1000 sensors for all high temperature applications; the operating range is: -100 to 200 °C. The inputs must be pre-configured for PT1000 Signals from the user terminal or using the default value installation procedure. The connection diagram is shown below: Max. number of inputs connectable to universal inputs/outputs pCO5+ Medium/ Built-in driver/ Extralarge Small - 0 to 20 mA/4 to 20 mA inputs from externally powered probes - 0 to 5 V signals from controller-powered ratiometric probes 10 4 4 5 6: (max 4 on U1...U5, 3 on U6...U8) 7: (max 4 on U1...U5, 3 on U6...U8) 6 6: (max 4 su U1...U5, 3 on U6...U8, 2 on U9...U10) 9: (max 4 on U1...U5, 3 on U6...U8, 2 on U9...U10) GND U5 GND U4 +VDC J3 GND U3 U2 J2 U1 J24 GND +Vterm J1 10 +5VREF 8 6 G0 5 6 G Tot. max. 8 5 Tot. max. 10 pR300 G - 0 to 20 mA/4 to 20 mA inputs from controller-powered probes 8 Tot. max. 7 Tot. max. 5 - 0 to 1 Vdc/0 to 10 Vdc signals from controller-powered probes - 0 to 1 Vdc/0 to 10 Vdc signals from externally powered probes Tot. max. 4 Analogue inputs - NTC/PTC/PT500/PT1000 5 probes Large Tot. max. 9 Type of signal Connecting PT1000 temperature sensors Fig. 3.b Hardware Version S, M, D, L 6 Terminals GND U1...U10 PT1000 probe cable 1 2 Tab. 3.d Tab. 3.b Important: for correct measurement by the PT1000 sensor, each sensor wire needs to be connected to a dedicated terminal, as shown in Fig. 3.b. Note: the two wires of the PT1000 sensors are equivalent, as they have no polarity, therefore it is not necessary to follow any specific order when connecting to the terminal block. Note: The table shows the maximum number of inputs that can be connected. For example, a Small controller can be connected to a maximum of five 0 to 1 Vdc inputs from controller-powered probes and a maximum of five 0 to 1 Vdc inputs from externally powered probes. In any case, the maximum number of inputs of both kinds that can be connected is 5. 3.3.1 Connecting universal NTC temperature sensors 3.3.3 For information on the maximum number of probes that can be connected see the table at the beginning of this paragraph. The analogue inputs are compatible with 2-wire NTC sensors. The inputs must be set for NTC Signals from the user terminal or using the default value installation procedure. The connection diagram is shown below: Connecting current pressure probes For information on the maximum number of probes that can be connected see the table at the beginning of this paragraph pRack pR300 can be connected to all CAREL SPK* series active pressure probes or any other pressure sensors available on the market with 0 to 20 mA or 4 to 20 mA Signal. The inputs must be set for 0 to 20 mA or 4 to 20 mA signals from the user terminal or using the default value installation procedure. The connection diagram is shown below: pR300 GND U5 GND J3 U4 +VDC GND U3 U2 J2 U1 J24 GND +Vterm G0 G J1 +5VREF GND U5 GND U4 +VDC J3 GND U3 U2 J2 U1 GND J24 +5VREF G0 G J1 +Vterm pR300 Fig. 3.a Hardware Version S, M, D, L Terminals GND U1...U10, S2, S4 Fig. 3.c NTC probe cable 1 2 Hardware Version S, M, D, L Tab. 3.c Note: the two wires of the NTC sensors are equivalent, as they have no polarity, therefore it is not necessary to follow any specific order when connecting to the terminal block. Terminals Probe wire colour Description +VDC U1...U10, S1, S3 brown white Power supply Signal Tab. 3.e Important: do not connect the green wire. 23 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG 3.3.4 Connecting 0 to 5 V ratiometric pressure probes Important: For information on the maximum number of probes that can be connected see the table at the beginning of this paragraph. pRack pR300 can be connected to any other pressure probes available on the market with 0 to 5 V ratiometric sensor. The inputs must be set for 0 to 5 V Signals from the user terminal or using the default value installation procedure. The connection diagram is shown below: • the maximum current available at the digital input is 5 mA (thus the rating of the external contact must be at least 5 mA). • these inputs are not optically-isolated. 3.3.7 Remote connection of the analogue inputs The Sizes of the cables for the remote connection of the analogue inputs are shown in the following table: GND U5 GND U4 +VDC J3 GND U3 U2 J2 U1 GND +Vterm J24 +5VREF G0 G J1 Type of input Size [mm2] for length up to 50 m Size [mm2] for length up to 100 m NTC PT1000 current voltage 1.0 1.5 0.5 0.5 0.5 0.75 0.25 0.25 Tab. 3.i Fig. 3.d Hardware Terminals Version S, M, D, L +5 V ref GND U1...U10, S1, S3 Probe wire colour black green white If the product is installed in industrial enviroment (in compliance for the EN 61000-6-2 standard) the length of the connections must be less than 30m. In any case you should never exceed this length to have no measurement errors. Description power supply power supply reference Signal Tab. 3.f 3.3.5 3.4 Connecting the digital inputs Connecting 0 to10 V active probes The pRack pR300 features digital inputs for connecting safety devices, alarms, device status and remote switches. These inputs are all optically isolated from the other terminals at 24 Vac, 24 Vdc and some at 230 Vac for M, D, L models. Note: separate the sensor Signal and digital input cables as much as possible from the inductive load and power cables, to avoid possible electromagnetic disturbance. Important: GND U5 GND J3 U4 GND U3 U1 U2 J2 +5VREF J24 GND +Vterm G0 G J1 +VDC For information on the maximum number of probes that can be connected see the table at the beginning of this paragraph. pRack pR300 can be connected to 0 to10 V sensors. The inputs must be set for 0 to10 V Signals from the user terminal or using the default value installation procedure. The connection diagram is shown below: • if the control voltage is drawn in parallel with a coil, fit a dedicated RC filter in parallel with the coil (the typical ratings are 100 Ω, 0.5 µF, 630 V). • If connecting the digital inputs to safety systems (alarms), remember that: the presence of voltage across the contact must be the normal operating condition, while no voltage must represent an alarm situation. This will ensure that any interruption (or disconnection) of the input will also be Signalled. Do not connect the neutral in place of an open digital input. Always interrupt the phase. The 24 Vac/Vdc digital inputs have a Resistance of around 5 kΩ. out H M out T + (G) Fig. 3.e Hardware Version Terminals +VDC S, M, L, D Description All pRack digital inputs can be powered at 24 Vac and 24 Vdc, while for models M, D, L only 230 Vac inouts are also available. To maintain the optical isolation of the digital inputs, a separate power supply must be used just for the digital inputs. The connection diagrams shown in these figures, which while being the more common and the more convenient, do not exclude the possibility of powering the digital inputs independently from the power supply to the pRack pR300. In any case, the inputs only have functional insulation from the rest of the controller. power supply (any) reference Signal GND U1...U10 Tab. 3.g 3.3.6 Connecting analogue inputs selected as ON/OFF 24 Vac digital inputs The following figure represents an example for connecting the 24 Vac digital inputs on pRack models S, M, L. GND U5 GND U4 +VDC J3 GND U3 U1 U2 J2 +5VREF J24 GND G0 G J1 +Vterm For information on the maximum number of probes that can be connected see the table at the beginning of this paragraph. The pRack pR300 allows some analogue inputs to be configured as voltage-free digital inputs, not optically-isolated. The inputs must be pre-configured as voltage-free digital inputs from the user terminal or using the default value installation procedure. G G0 Fig. 3.f Hardware Version S, M, D, L Terminals GND U1...U10 Digital input cable 1 2 Tab. 3.h pRack +0300025EN rel. 1.5 - 17.02.2020 Fig. 3.g 24 ENG 24 Vdc digital inputs The following figure represents an example for connecting the 24 Vdc digital inputs on pRack models S, M, L. Hardware Version S, M, D L + – Fig. 3.h 230 Vac digital inputs pRack M, D, L models have up to two groups of inputs powered at 230 Vac 50/60 Hz +10/-15%; each group features two inputs. The groups have double insulation between them and can have different voltages. Important: within each group the inputs must be powered at the same voltage to avoid short-circuits or powering lower voltage inputs at 230 Vac. Module for converting a 0…10 V analogue output to an SPDT digital output (code CONVONOFF0) The module is used to convert a 0…10 V analogue output to an ON/OFF relay output. The control Signal (at the input terminals, optically-isolated from the rest of the module), to ensure the switching of the relay from OFF to ON, must have a maximum amplitude of 3.3 V. The relay is SPDT, with max current of 10 A and max inductive load of 1/3 HP. The mechanical dimensions of the module are 87x36x60 mm (2 DIN mod.) with IP20 index of protection. The range of uncertainty of the switching threshold is from 43 to 90 Vac. It is recommended to use a 100 mA fuse in series with the digital inputs. The following figure represents an example for connecting the 230 Vac digital inputs on pRack models M, D, L. ID18 DC17 ID17 U10 Y6 U9 GND Y5 ID16H ID16 GND J20 J19 IDC15 Optional modules Module for converting a PWM analogue output to a liner 0…10 V and 4…20 mA analogue output (code CONV0/10A0) The module is used to convert a PWM output (5 V pulses) to a liner 0…10 V and 4…20 mA analogue output (code CONV0/10A0). The control Signal (at the input terminals optically-isolated from the rest of the module) must have a maximum amplitude of 5V and a period between 8 ms and 200 ms. The 0…10 V output voltage can be connected to a maximum load of 2 kW, with a maximum ripple of 100 mV. The 4…20 mA current output can be connected to a maximum load of 280 W, with maximum overshoot of 0.3 mA. The mechanical dimensions of the module are 87x36x60 mm (2 DIN modules) with IP20 index of protection. 24 Vdc ID15 Reference VG0 VG0 Tab. 3.j 3.5.2 ID15H Terminals Y1, Y2, Y3, Y4 Y1, Y2, Y3, Y4, Y5, Y6 3.6 Connecting the digital outputs 3.6.1 Electromechanical relay digital outputs 110/230 - 24 Vac The pRack pR300 features digital outputs with electromechanical relays. For ease of installation, the common terminals of some of the relays have been grouped together. The following figure illustrates a connection example. If the following this diagram is used, the current at the common terminals must not exceed the rating (nominal current) of a single terminal (8 A). Fig. 3.i 3.4.8 Remote connection of the digital inputs Important note: do not connect other devices to the digital inputs IDn inputs. The Sizes of the cables for the remote connection of the digital inputs are shown in the following table: Size (mm2) for length up to 50 m Size (mm2) for length until 100 m Fig. 3.k If the product is installed in industrial environments (application of the EN 61000-6-2 standard) the length of the connections must be less than 30 m. This length shouldn’t be exceeded in any case, to avoid measurement errors. The relays are divided into groups, according to the degree of insulation. Inside each group, the relays have just basic insulation and thus must have the same voltage (generally 24V ac or 110 to 230 Vac). Between the groups there is double insulation and thus the groups can have different voltages. There is also double insulation from the rest of the controller. 0,25 0,5 Changeover outputs Some relays feature changeover outputs, the number of changeover outputs depends on whether or not there are solid state relays (SSR) and consequently varies depending on the models. 3.5 Connecting the analogue outputs 3.5.1 Connecting 0…10 V analogue outputs The pRack pR300 provides 0…10 V optically-isolated analogue outputs, powered externally at 24 Vac/Vdc. The figure below shows the electrical connection diagram; the 0V (zero) of the power supply is also the reference for the output voltage: Hardware version PRK300**F* models S 8 M, D 8, 12, 13 L 8, 12, 13, 14, 15 ID18 ID17 GND U10 U9 GND Y6 Y5 J20 Terminal J15 J15, J17, J18 J15, J17, J18, J21 Tab. 3.k 3.6.2 Solid state relay (SSR) digital outputs The pRack pR300 also features a Version with solid state relays (SSR) on some models for controlling devices that require an unlimited number of switching cycles and thus would not be supported by electromechanical relays (e.g. screw compressor valves). They are dedicated to loads powered at 24 Vac/Vdc with a maximum power Pmax = 10 W. Vout Vout Vout Vout Vout Vout 24 Vac/Vdc 0V Changeover relay reference, without SSR model Important: the SSRs can control resistive loads powered at 24 Vac/Vdc. For details see paragraph 2.2.8. Fig. 3.j 25 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG The figure shows a connection example for resistive loads. 3.6.4 Remote connection of the digital outputs 24 Vac The Sizes of the cables for the remote connection of the digital outputs are shown in the following table: Size [mm2] 0,5 1,5 2,5 AWG 20 15 14 Current [A] 2A 6A 8A Tab. 3.n If the product is installed in industrial environments (application of the EN 61000-6-2 standard) the length of the connections must be less than 30 m. This length shouldn’t be exceeded in any case. Fig. 3.l The following figure illustrates correct applications for inductive loads. 3.7 pLAN electrical connections external SSR NO11 C9 NO17 If the selected system configuration involves the connection of more than one pRack pR300 board in a pLAN, AWG20/22 twisted pair shielded cable must be used, with capacitance between the wires less than 90 PF/m. The maximum length of the pLAN network is 500 m with AWG22 twisted pair shielded cable. The boards should be connected in parallel with reference to plug-in connector J5 (pRack Compact) or J11 (versions S, M, L). C15 J16 J21 J26 FBus2 NO18 C9 NO9 NO10 C16 NO16 C8 NC8 J15 NC15 C7 1 NC14 2 NO15 C7 3 NO14 4 C14 J14 J10 J25 BMS2 NO8 C4 NO7 NO6 C4 NO5 C1 J13 J12 J11 pLAN NO4 C1 NO3 NO2 NO1 input load management J22 pR300 ID16H ID16 IDC15 ID15 ID15H ID11 ID10 GND U8 U7 J6 ID9 IDC1 U6 ID8 ID7 J7 ID5 ID4 ID3 ID2 The figure shows the diagram for more than one board connected in a pLAN network; this is a typical application with more than one board connected inside the same electrical panel. Fig. 3.m AWG 20/22 U9 GND ID13H ID13 Y6 Y5 ID16H ID16 IDC15 ID15 ID15H IDC9 ID12 ID11 ID10 GND U8 ID9 U7 IDC1 U6 ID8 ID7 J6 Reference relay SSR 7, 8 7, 12 7, 8, 12, 13, 14, 15 NC1 2 NO1 NO2 NO13 C9 C12 C1 NO12 C9 NO9 NO11 NO10 NO18 C16 U9 GND U10 ID13 IDC1 VG 3 Y6 Y5 ID13H IDC9 ID12 GND ID11 U5 ID10 GND ID16 ID16H GND +VDC U8 GND U7 U3 J2 J6 J7 J3 ID9 U4 IDC15 ID15 IDC1 U1 ID15H +5 VREF ID8 +Vterm J24 ID6 GND ID7 ID5 ID4 G0 ID3 G ID2 Y4 ID1 Y3 Y2 Y1 VG0 VG GND U5 GND U4 +VDC GND U3 J1 J20 FieldBus card Important: pLAN connections are possible in which more than one board is powered by different transformers; for further details see pRack system general manual: +030220335. Terminal J14, J15 J14, J17 J14, J15, J17, J18, J21 Tab. 3.l 3.7.1 The connection can be made using 6-wire telephone cables (connector J4 for Compact models or J10 for S, M, L) or shielded twisted pair cables with 3-pin plug-in connectors (connector J5 for Compact models or J11 for S, M, L), as shown in the table Summary table of digital outputs according to the Versions available Changeover contact n.ro outputs relay in SSR 2 (8, 13) - 8 13 18 2 (7, 8) 2 (7, 12) 6 (7, 12, 13, 14, 15) Connecting the terminals pRack pR300 uses PGD1 terminals, either built-in or external connected via pLAN. Up to 2 external terminals can be connected, with pLAN addresses 31 and 32. Important: the SSR relay load is powered at 24 Vac/Vdc, thus all the other terminals in the group must be powered at 24 Vac/Vdc due to the absence of double insulation within the group. Hardware NO NC version contacts contacts PRK300**E* Models S 6 M, D 9 L 12 - J3 J5 Fig. 3.p The table below shows the reference outputs for pRack models fitted with SSR outputs. 3.6.3 U2 U1 +5 VREF G0 J2 J4 J7 ID6 ID5 ID4 ID3 ID2 ID1 Y4 Y3 J5 Y2 VG0 VG GND Y1 J4 U5 GND U4 +VDC J24 Fig. 3.n Hardware version S M, D L C16 pR300 J19 B M S c ard J19 B M S ca r d J3 GND U3 U2 U1 +5 VREF GND G0 +Vterm G J2 +Vterm G J1 GND pR300 J24 J23 FBus2 J22 J23 F J22 FieldBus card J1 NO17 C15 NC15 J21 J26 FBus2 pR300 Fi eld Bus car d J1J1 72 J16 NO16 C8 C7 NC8 NC14 NO15 C7 NO8 J15 J11 pLAN 2 1 J10 C14 C4 NO7 C4 NO6 NO5 C1 J25 BMS2 3 NO14 C12 NC12 NO12 J14 4 C16 NO17 NO18 NO16 C16 C15 NC15 J13 J10 J17 J16 J21 J26 FBus2 C9 NO11 C9 NO9 NO10 C8 C7 1 NC8 NO8 C14 2 NC14 3 NO14 4 J15 NO15 J14 J10 J25 BMS2 NO7 C7 C4 NO6 C4 NO5 NO4 C1 NO3 NO1 C1 NO2 J13 J12 NO4 C1 J12 J11 pLAN J11 pLAN NO3 input load management NO2 external SSR NO1 24 Vac/Vdc AWG 20/22 Dedicated or the same of G-G0 but not in common with other external load U6 U2 ID1 Y4 Y3 J5 Y2 Y1 VG0 VG GND U5 GND U4 +VDC GND Important: follow the network polarity: RX/TX+ on one board must be connected to RX/TX+ on the other boards; the same applies to RX/TX-. J19 B M S car d J4 J3 U3 U2 +5 VREF J2 U1 GND G0 +Vterm G J24 ID6 Fi eld Bus car d J1 Cable type 6-pin phone (J10) AWG24 AWG20/22 Power supply distance 10 m Power supply Taken from pRack (150 mA) 200 m 500 m Taken from pRack (150 mA) Separate, via TCONN6J000 Tab. 3.o PRK300**F* Models S 7 M, D 10 L 13 - 1 (8) 3 (8, 12, 13) 5 (8, 12, 13, 14, 15) 8 13 18 - For further details on connecting the terminals, see the pRack system general manual: +030220335. Tab. 3.m pRack +0300025EN rel. 1.5 - 17.02.2020 26 ENG 4. START UP 4.1.1 4.1 Starting the first time Pre-configurations After having correctly installed pRack, a number of preliminary operations are required to configure the installation. Tutorial: the pRack pR300 configuration procedure varies according to the complexity of the installation: A. systems with only one board and maximum one external terminal. In this case, simply connect the terminal (if not built-in), power up the board and select one of the configuration solutions described below. B. systems with more than one board in pLAN or two external terminals. IIn this case, the additional operations described in Appendix A. 2 need to be completed before proceeding with configuration. This solution is used to choose between fourteen configurations preloaded in the pRack pR300 software. For the description of the preconfigurations see the table below, while for the complete description of each configuration see Appendix A1. pRack pR300 automatically configures the inputs and outputs as described in paragraph 4.1.4; for details on the inputs and outputs associated with each pre-configuration, see the quick guide code +040000070. The procedure for configuring an installation described below is the same for all system configurations that feature just one pRack pR300 board, and for system configurations with more than one board connected in a pLAN. When first starting the pRack pR300 board, after waiting around 1 minute, a screen is shown for choosing the language used to display the program (English or Italian). Press ENTER ( ) to change the language displayed, while pressing ESC displays the following screen. 4.1.2 Wizard Note: • If no option is chosen within a time set by parameter and visible on the screen, the current language remains selected. • pRack pR300 is available as standard with English and Italian languages loaded on board. Other languages are available at ksa.carel.com that can be loaded onto the control using the pRack Manager software, following the procedure described in Chap. 10. This solution is used to obtain the recommended configuration for the specific installation. By responding to a series of questions, screen by screen, the user is guided through the selection of the devices present. Once the guided selection procedure has been completed, the end result (report) is shown, and if the configuration is suitable the parameters to start operation of the pRack pR300 can be installed directly, including those associated with the inputs and outputs as described in parag. 4.1.4. After having selected the user interface language, the pRack pR300 software shows a screen for choosing between three possible system configuration solutions, as follows: • Pre-configurations • Wizard • Advanced configuration. Note: after having configured the parameters using the Wizard, the configuration can be modified manually, within the context of the selected system configuration. Important: • after having configured the system, the configuration can be modified, Important: before starting the pRack pR300, carefully check the settings made automatically by the software. it can be modified by repeating the same procedure, making sure the Carel default values have been reset as described in paragraph 6.8.2. • after having configured the system, power down the controller and power up again. Tutorial: Appendix A.3 shows a configuration example using the Wizard for an installation with two suction lines. Summary of pre-configurations compressors type N° index lines 1 2 3 4 5 6 7 8 9 10 11 RS2 RS3 RS3p RS3i RS4 RS4i SL3d SL5d SW1 SW2 d-RS2 1 1 1 1 1 1 1 1 1 1 2 Piston - Scroll Piston - Scroll Piston - Scroll Piston - Scroll Piston - Scroll Piston - Scroll 12 d-RS3 2 Pistoni - Scroll 13 d-RS4 2 Pistoni - Scroll Scroll Scroll Screw Vite Pistoni - Scroll N° capacity step modulation 2 3 3 3 4 4 3 5 1 2 2 2 3 3 4 4 1 Inverter Inverter Digital Digital Inverter Inverter 2 2 - No. of comp. alarms 1 1 2 3 2 3 1 1 2 2 1 1 1 1 3 3 fans N° inverter 2 3 1 1 4 1 2 1 2 1 2 Inverter Inverter Inverter Inverter Inverter - 3 3 1 1 Inverter Inverter Units in the pLAN(as well pRack pR300 Version as the terminal) 1 1 1 1 1 1 1 1 1 1 1 Small Small Medium Medium Medium Large Medium Medium Small Small Medium 1 Large 1,2 Medium + Medium Tab. 4.a (*) configuration not available in versions 1.0 and 1.1 of the pRack software. 27 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG 4.1.3 Advanced configuration This solution is used to establish the configuration of the pLAN structure required for correct system operation. Once the procedure for selecting the various factors that affect the final configuration has been completed, the pRack pR300 software verifies whether the pLAN configuration is exact and prepares the user interface for configuration of the parameters that need to be set manually by the user. Important: this configuration solution is only recommended for expert users, as all the system parameters need to be set manually. 4.1.4 Associating the inputs and outputs When using pre-configurations and the wizard, pRack pR300 can automatically associate the board’s inputs and outputs with the various functions. For the wizard only, after having configured the lines, automatic association can be chosen as an option. If choosing not to use this function, the I/Os need to be configured manually, according to requirements. The criteria applied for automatic association are described below. Digital outputs pRack pR300 assigns in order: • Compressor outputs: first the SSR outputs for screw or Digital Scroll™ then the starting outputs, the capacity control valves and the inverter, if present • Fan outputs • Global alarm. Digital inputs pRack pR300 assigns in order: • High and low pressure switches (HP and LP) • Compressor alarms • Fan alarms Note: pRack pR300 can also use certain analogue inputs as digital inputs, nonetheless the common HP and LP pressure switches are always associated with actual digital inputs. Analogue inputs pRack pR300 assigns in order: • Pressure or temperature control probes for 1 or 2 lines, according to the settings made. The types of probe asSigned as default are 4…20 mA or 0 to 5 V (first 4…20 mA, then 0 to 5 V if necessary) for the pressure probes, NTC for the suction temperature probes and HTNTC for the condensing temperature probes; • Suction temperature probe on line 1: if possible this is associated with input B3, otherwise the first free input; • Discharge temperature probe on line 1; • Suction temperature probe on line 2; • Discharge temperature probe on line 2. Analogue outputs pRack pR300 assigns in order: • Compressor inverters for 1 or 2 lines; • Fan modulating devices for 1 or 2 lines. pRack +0300025EN rel. 1.5 - 17.02.2020 28 ENG USER INTERFACE 5. Customised main screen pRack pR300 offers the possibility to configure the information displayed on the main screen and the second screen (pressing DOWN) as desired. For example, information on specific probes with physical readings (pressure or temperature), no longer grouped by screen but rather customised rowby-row on the display. The basic structure comprises two screens that are scrolled by pressing Up and Down; all the information can be configured for display on the main screen relating to pressure or temperature, the characteristic that is not selected will then be displayed on the secondary screen, only if significant. 5.1 Graphic terminal The pRack pR300 user interface is represented by the pGD1 terminal, panel or built-in versions. The functions associated with the 6 buttons on the pGD1 terminal are the same on all the screens and are described in the table below. Functions of the 6 buttons Button Function associated (ALARM) displays the list of active alarms and accesses the alarm log used to enter the main menu tree (UP) (DOWN) (ENTER) Main screen returns to the higher level screen scrolls a list upwards or increases the value highlighted by the cursor scrolls a list downwards or decreases the value highlighted by the cursor enters the selected submenu or confirms the set value. Tab. 5.a The LEDs associated with the buttons have the following meanings. Meaning of LEDs LED Red éê Button Meaning Flashing: active alarms present and not acknowledged Steady: alarms present and acknowledged Yellow Secondary screen pRack pR300 on Green pRack pR300 powered Tab. 5.b 5.2 Description of the display There are three fundamental types of screens shown to the user: • Main screen • Customised main screen • Menu screen • Screen for displaying/setting the parameters Fig. 5.b In the example, a suction line with control by pressure has been configured, the main screen displays the values read by the suction and condensing pressure probes, while the superheat is displayed in degrees centigrade; the secondary screen will show the converted temperatures of the suction and condensing pressure probe readings, together with the description of superheat by pressure, which is not displayed as this information would not be significant. By default the main screen will continue to show the same information as always displayed on the pR100 (depending on the type of configuration: SUCTION&CONDENSER, rather than SUCTION and the type of control PRESSURE/TEMPERATURE). Main screen The main screen is the screen that the software on board pRack pR300 automatically returns to 5 minutes after the last button was pressed. An example of the main screen is shown in the figure, highlighting the fields and icons used: 1 When starting the first time, the main screen will reflect the settings made. Custom configuration of the main screen is then performed subsequently, as described below: The configuration is made under Settings -> Language in screen Fb04 2 4 3 5 Fig. 5.a 1 2 3 4 5 Time and date Main values. Unit status (unit off ) or compressor and fan status (unit on) Active alarm Signal and manual operation Access further information screens (menu branch A.a) by pressing button On this screen, users can choose whether to configure the part relating to the probes, or the bottom bar with the percentages or number of active peripherals in the circuit. Note: • the information shown on the main screen varies according to the system configuration (one line, two lines, two lines with shared condenser) and the type of control value used (pressure or temperature). For two line systems, a parameter is used to select which line is shown first. • the other information shown in menu branch A.a. varies according to the system configuration. For two line systems, pressing from the main screen accesses a different screen based on the starting point (line 1, line 2). 29 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG The screen identifier uniquely identifies the menu branch and the screen: the first characters indicate the menu branch, while the last two alphanumeric digits identify the screen within the menu; for example screen Bab01 is the first screen in menu Bab. On screen Fb04, go to the field underneath “Probe configuration”, change the value to “CONFIGURE” and press Enter. The following screen (Fb05) is displayed, which shows the layout of the main screen with the modifiable fields for each row. The following options are available: Probe Suction Condenser Superheat L1 – Suction L2 – Suction L1 – Condenser L2 – Condenser Suction temperature L1 - Suction temperature L2 - Suction temperature Discharge temperature L1 – Discharge temperature L2 – Discharge temperature Auxiliary L1 - Auxiliary L2 - Auxiliary L1 - Superheat L2 - Superheat EVD1 - Condenser EVD2 - Condenser Description Suction used for single suction line Condenser used for single condenser line Superheat used for single suction line Suction on line 1 Suction on line 2 Condenser on line 1 Condenser on line 2 Suction temperature for single suction line Suction temperature on line 1 Suction temperature on line 2 Discharge temperature for single suction line Discharge temperature on line 1 Discharge temperature on line 2 Auxiliary probe for single suction line Auxiliary probe on line 1 Auxiliary probe on line 2 Superheat on line 1 Superheat on line 2 Condenser line 2 connected to driver 1 Condenser line 2 connected to driver 2 Note: the information contained on the screens may vary according to the password level used to access it. 5.3 Password pRack pR300 manages three levels of password: • User • Maintenance • Manufacturer Each level includes the same rights as the lower levels, that is, the Manufacturer can access all the screens and parameters, the Maintenance can access the screens and parameters available in the Maintenance and User levels, while the User can only access the screens and parameters available in the User level. Tab. 5.c Note: All levels display the main screens and the other information screens. When pressing a prompt is shown to enter the password, which remains active for 5 minutes after the last button is pressed. After having configured the required information, choose the characteristic to be displayed on the main screen, Pressure or Temperature. The menu screens show their own password level using an icon at the top right: 1 line: user, 2 lines: maintenance, 3 lines: manufacturer. The password level can be changed from menu branch F.d. at any time. The password can also be changed in the corresponding menu branch. To exit this screen, simply press Esc and return to the Language menu. 5.4 Description menu Main menu – Function tree The following general rules apply to the user interface: • The parameters are grouped by functions and where necessary repeated, for example the status of the compressors inputs/outputs is visible in both branch C.a.a (Compressors), and in branch B.a (Inputs/ Outputs) • The parameters are grouped by type of access, first User then Maintenance then Manufacturer • The most frequently used parameters are indicated first, the less frequently used are last • Each user only sees the parameters and menu items that are available for that access level • Only the screens and parameters corresponding to the selected system configuration are visible, that is, corresponding to the devices configured. The exception to this rule involves the screens relating to functions that can be enabled/disabled (e.g. set point compensation), which are visible even when disabled. Menu screen An example of a menu screen is shown in the figure: In the top right corner, the number of the selected item among those present and the current password level are shown (see the following par. & buttons sto select the desired menu item for details). Use the and use to access the selected item. Parameter display/setting screen An example of a screen for displaying/setting the parameters is shown in the figure, also highlighting the fields and icons used: Fig. 5.b 1 Menu branch identifier 2 Screen identifier 3 Parameters pRack +0300025EN rel. 1.5 - 17.02.2020 30 ENG Regardless of the current screen displayed, pressing the button accesses the main menu, as shown below: A.Unit status B.In/Out a.Main info b.Set point c.On/Off a.Status C.Compressors a.Line 1 (*) D.Condensers b.Line 2 (*) a.Line 1 (*) E.Other func. b.Line 2 (*) a.Oil a.Digital in b.Analog in c.Digital out d.Analog out a.Digital out b.Analog out a.Digital out b.Analog out a.I/O status b.Control c.Op. hours d.Energy saving e.Alarms f.Config. g.Advanced …. a.I/O status b.Control c.EEV d.Energy saving e.Alarms f.Config. g.Advanced …. a.Line 1 (*) b.Subcool b.Line 2 (*) a.Line 1 (*) c.Economiser b.Line 2 (*) a.Line 1 (*) d.Liquid inj. b.Line 2 (*) a.Line 1 (*) e.Heat recovery b.Line 2 (*) a.Line 1 (*) b.Manual op. c.Test f.Generic func. g.ChillBooster h.DSS (*) i.EVS F.Settings. a.Clock b.Languages c.BMS G.Safety d.Password a.Log b.Prevent c.Alarm config. H.Info I.Setup b.Line 2 (*) a.Stages b.Modulation c.Alarms d.Time bands e.I/O status a.Line 1 (*) b.Line 2 (*) a.I/O status b.Settings a.Temperature control b.Manual management c.I/O status d.Control e.Valve configuration f.Driver configuration aTime bands b.Adjust a.I/O status b.Settings …. a.I/O status b.Settings c.EEV …. a.I/O status b.Settings c.EEV …. a.I/O status b.Settings …. a.I/O status b.Settings …. a.I/O status b.Settings. …. a.Line 1 (*) b.Line 2 (*) a.Line 1 (*) b.Line 2 (*) a.Line 1 (*) b.Line 2 (*) a.Pre-configurations b.Wizard c.Advanced config. d.Default (*) this menu level is only visible for system configurations with two lines. Note: • The figure illustrates the maximum menu configuration visible with the Manufacturer password. If accessing with the User or Maintenance password, only the menu items available are visible • For some menu items, access is possible with different password levels (e.g. I/O status), but the information available on the screens changes. . 31 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG 6. FUNCTIONS pRack pR300 can manage up to 2 suction lines and 2 condenser lines. Many of the functions described in this chapter apply in the same way to all the lines (e.g.: control, rotation), while others apply in the same way to the suction lines (e.g.: oil management). The exception involves the generic functions that apply, irrespective of line, suction or condenser, to pRack boards with pLAN addresses from 1 to 4. Where not expressly indicated or where it is clear that the description refers to one specific line rather than another (e.g.: compressor or fan management), the descriptions are considered as being common to all lines; any specific Situations are described on a case-by-case basis. When there are two suction and condenser lines, on-off is independent for each line, while when there are two suction lines and one condenser line, it is independent for the suction lines, while the condenser line stops when both suction lines are off, and starts when at least one suction line is on. Note: Certain special conditions or functions in the pRack software cause the unit to shutdown: • Configuration of some parameters: e.g. inputs/outputs, configuration of compressors, inverter parameters. • Installation of default parameters • Manual management Below is a chart of the main functions described and their field of application: Function Control Compressors Energy saving Accessory functions Unit On-Off P+I control Control in Neutral zone Modulation in Neutral zone Control with backup probes Rotation Modulation device Screw compressors Reciprocating and scroll compressors Digital Scroll™ compressors Bitzer CRII compressors Fan management Set point compensation Floating set point Oil management Subcooling Economizer Liquid injection Heat recovery Generic functions (*) ChillBooster DSS L1 suc- L2 suc- L1 con- L2 contion tion dens. dens. √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ (*) √ √ √ √ √ √ √ √ √ (*) √ √ √ √ √ (*) √ - 6.2 Control pRack pR300 can manage two types of control: • Proportional band (P, P+I); • Neutral zone (fixed times, variable times). Both types of control can be applied to both compressors and condensers, according to the settings defined during start-up or in main menu branches C.a.b/C.b.b and D.a.b/D.b.b. The type of control chosen is independent for each line present, either suction or condenser. In addition, pRack pR300 can use as the reference for control either the pressure or the converted temperature, or the temperature read by probe if there is no pressure probe, even if reference is only made to pressure below. √ √ √ √ (*) √ - The control set point can be compensated by an offset linked to digital inputs, probes, supervisor or time bands, for details see paragraph 6.5 relating to compressor and fan energy saving. Both types of control are described below, and are valid for both control of suction pressure and condensing pressure, and operation with backup probes and/or probes not working. Tab. 6.a (*) not linked to lines, but rather the pLAN address of the boards 6.2.1 The functions are described in detail in the following paragraphs. The operating principle is normal proportional or proportional + integral control (P, P+I). The control set point is central, consequently - for proportional control only - operation is schematised in the following figure: Proportional band 6.1 Unit On-Off Regulation request The unit can be switched on and off from: • User terminal • Supervisor • Digital input 100% On-off from the user terminal and the configuration parameters are available under the main menu, branch A.c, and are differentiated based on the access level; the User password allows display only. On-off from the supervisor and from the digital input and start-up after a blackout (with specific delay, to avoid continuous starts and stops in the event of instability in the power supply) must be enabled using the parameters visible only with the Manufacturer password. On-off from the digital input is equivalent to an enabling Signal, that is, if the digital input is Off the unit cannot be switched on in any other way, while if is On, the unit can be switched on or off in any other way, with the same priority (the most recent control has precedence, whatever the origin), as shown in the figure: Differential Differential Regulation probe value Setpoint Fig. 6.b For example, for 4 devices with the same capacity and proportional only control, start-up occurs as shown in the figure: Devices activation Digital Input C1 C2 C3 C4 User interface Supervisor Differential Differential Setpoint Unit On/Off Fig. 6.c Fig. 6.a pRack +0300025EN rel. 1.5 - 17.02.2020 32 Suction pressure ENG With P+I control, added to the effect of the proportional action described above is the integral action, used to achieve a null control error in steady operation, as shown in the figure: For control in Neutral zone, the parameters shown in the figure must be set: NZ timings Decrease zone Regulation variable P+I Neutral zone Increase zone Max time 100% P Max time 0% Min time 0% Setpoint Min time 100% time Fig. 6.d Decr. Diff. The integral action depends on the time and the deviation from the set point. This modifies the request if the control value does not approach the set point for some time. The integral time setting represents how fast integral control is implemented: • low values determine fast and intense control action • high values determine slower and more stable control action It is recommended to not set a value that is too low for the integral time, to avoid instability. Diff. Incr. Diff. Regulation probe value Setpoint Fig. 6.f As well as the decrease and increase differentials, 4 times need to be set, two for each zone, which represent the maximum and minimum time to reach the request, equal to 0% or 100%, for the decrease and increase respectively. Tutorial: the decrease/increase times (minimum and maximum) represent the time needed to change from maximum to minimum capacity and vice-versa, and not the time between the deactivation/ activation of the individual device. For example, in the case of 4 devices with the same capacity, an increase time of 180 s means that one device is activated every 45 s. Note: the set point is in the centre of the activation band, therefore when reaching the set point some devices are on, even with purely proportional control. 6.2.2 Diff. Neutral zone In the situation shown in the figure, the request sent by the controller decreases/increases slowly as soon as the controlled value is outside of the Neutral zone, while it decreases/increases quickly the further the controlled value moves away from the Neutral zone; in this way the response of the system is faster when further from steady conditions. The operating principle is schematised in the following figure: Regulation request Decrease zone Neutral zone Increase zone Note: When using fixed times, the maximum and minimum must be set to the same value. In this case, the request sent by the controller decreases/increases constantly inside the deactivation/activation differential. 100% 6.2.3 Force off Diff. Diff. Modulation in Neutral zone pRack pR300 can activate a specific function inside the Neutral zone if modulating devices are used (e.g.: inverters). This function can be enabled in main menu branch C.a.g/C.b.g or D.a.g/D.b.g. Regulation probe value Modulation in Neutral zone is used to vary the request sent by the controller inside the Neutral zone proportionally so as to enter the decrease zone with the minimum request and the increase zone with the maximum request, meaning a device can be immediately deactivated/ activated when exiting the Neutral zone. This makes it possible to remain longer inside the neutral zone without starting or stopping any device. Setpoint Fig. 6.e Inside the neutral zone the capacity request sent by the controller is constant (except when there is a modulation device and modulation is enabled inside the neutral zone, as described in the following paragraph) and the value satisfies the temperature control request in those specific operating conditions, therefore within this zone no device is stopped or started. An example of this operation is shown in the figure: Regulation request In the decrease zone, the request also decreases at a rate that depends on the deviation from the set point, and vice-versa in the increase zone the request increases proportionally to the deviation. Neutral zone 100% For the increase and decrease zones, the following can be used: • Fixed times: the request decreases or increases constantly as time elapses. • Variable times: the request decreases or increases more quickly (according to the settings) as the deviation from the set point increases. P1 Note: The previous figure shows the increase and decrease with fixed times. Regulation probe value Fig. 6.g 33 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG When entering the Neutral zone, the pRack pR300 software calculates how the request needs to change in order to exit the Neutral zone at minimum or maximum output, and applies one of the two values according to the trend in variation in the control variable. For example, at point P1 in the figure, the trend of the two requests is represented by the segments with thin lines, and the request ‘reverses’ because at that point the control variable has started increasing in value again. Note: When exiting the Neutral zone, it is possible that the request is not at the minimum or maximum value, where limitation is enabled for of the modulating device variation speed. 6.2.4 Control with backup probes and/or probes not working pRack pR300 can use backup control probes that are activated when the normal control probes are not working. The backup probes must be enabled in main menu branch C.a.g/C.b.g or D.a.g/D.b.g. The type of control, band limits or differentials and the set point need to be configured under “Compressors -> Control”, in the same way as for traditional control. When different pRack boards are used to manage the suction and condenser lines, the backup suction pressure probe must be connected to the board that manages the suction line, while the backup condensing pressure probe can be connected either to the board that manages the suction line or the board that manages the condenser line. The limits for the auxiliary probe alarms, are set under “Compressors -> Alarms” and need to be configured depending on the type of probe and refrigerant. When an alarm goes off, this is saved in the log, with a special screen shown when pressing the alarm bell. If the main control probes are not working and no backup probes are fitted, or the backup probes are also not working, or the corresponding temperature probes are also not working, fixed values are used for the control request, set in main menu branch C.a.g/C.b.g or D.a.g/D.b.g. 6.2.5 Auxiliary control pRack pR300 offers the possibility to control the compressors on a single suction line (or L1 for double lines) using an auxiliary probe. Normal control based on the suction pressure probe reading (or converted temperature) can be replaced by control based on a different probe. This solution can manage the secondary refrigerant in “water chiller” or “pumped” systems, offering greater system stability and at the same time guaranteeing compressor safety via the suction probe, which must always be installed. Auxiliary control is enabled under “Compressors -> Control”, selecting the type of control (by temperature or pressure) and the type of refrigerant, which may differ from the main one. The function does not need to be enabled if “water chiller” is set in the installation Wizard: as auxiliary control by temperature probe is enabled automatically. Choosing a “pumped” system, on the other hand, automatically enables auxiliary control by pressure probe (see Appendix A.2) Note: when auxiliary control is enabled, it is recommended to also enable the prevent low suction pressure function, see paragraph 8.3.4 (prevent low suction pressure). In case of pumped systems, don’t configure the second condensing line. Once the auxiliary probe is enabled on screen Cab20, the associated universal input, the probe type, the correct limits (for pressure probes) and calibration (if necessary) can be selected under “Inputs Outputs -> Status -> Analogue inputs” pRack +0300025EN rel. 1.5 - 17.02.2020 34 ENG 6.3 Compressors 6.3.2 pRack pR300 can manage up to 2 suction lines with different types of compressors and capacity modulation devices, applying common types of device rotation and controlling both the start mode and the safety times for each type of compressor, as well as a number of accessory functions. pRack pR300 can manage 4 different types of device rotation: • FIFO (First In First Out): the first device to start is also the first to stop • LIFO (Last In First Out): the last device to start is the first to stop • By time: the device with the least number of operating hours starts and the device with highest number of operating hours stops • Custom: the on/off sequences are defined by the user The compressor functions and related parameter settings are enabled from main menu branch C.a/C.b. Rotation These features and functions are described in detail in the following paragraphs. Note: Different Sizes of compressors can only be managed with Custom rotation. 6.3.1 The type of rotation is selected and the corresponding parameters set during the start-up procedure or in main menu branch C.a.f/C.b.f. Possible compressor configurations pRack pR300 can manage different types of compressors: • Reciprocating • Scroll • Screw Moreover, a capacity modulation device is allowed for each suction line, which may be one of the following, according to the type of compressor: The activation thresholds are calculated differently depending on whether FIFO, LIFO, time or Custom rotation is used: Device activation threshold calculation Rotation FIFO LIFO By time Custom Compressors and modulation devices Compressors Reciprocating modulation devices Inverter Inverter Digital Scroll™ Inverter Continuous capacity control Modulating capacity control Scroll Screw Bitzer CRII Threshold calculation Static: the range of variation of the control request is divided equally between the number of stages available Dynamic: the thresholds are calculated depending on the capacity effectively available Tab. 6.d Example 1: FIFO rotation, 4 compressors of the same capacity without load stages. Tab. 6.b Note: The same modulation device is used on each line. The activation thresholds are 25, 50, 75 and 100 %. The maximum number of compressors and load stages per line varied according to the type of compressor: C2 C1 C3 C4 Compressors and modulation devices Compressors Reciprocating Scroll Screw Bitzer CRII Maximum No. 12 12 2 2 Load stages 24 total 24 total 4 3 25% 50% Example 2: Custom rotation, 4 compressors with capacities of 10, 20, 30 and 40 kW. The activation thresholds with all the compressors available are 10, 30, 60, 100 %. Note: Screw compressors can only be configured on line 1 and the board must be dedicated only to line 1. One Bitzer CRII compressor can be configured for each line. The compressor size refers to its capacity and number of load stages or to the inverter presence, therefore different sizes need to be defined for compressors with the same capacity yet a different number of load stages. The inverter is always associated to size 1. C1 C2 10% Tutorial: below is one example of some possible configurations: C3 30% C4 60% • One line, 4 reciprocating compressors with the same capacity, the first • • • • 100% Regulation request Fig. 6.h Tab. 6.c • 75% 100% Regulation request Fig. 6.i with inverter (2 sizes). One line, 4 scroll compressors with the same capacity, the first Digital Scroll™ (1 sizes). One line, 4 reciprocating compressors with the same capacity, the first two with 4 load stages, the other two not capacity-controlled (2 sizes). One line, 4 reciprocating compressors with the same capacity and 4 load stages each (1 size). Two lines, line 1 with 2 screw compressors with the same capacity, the first with continuous modulation, line 2 with 4 reciprocating compressors with two different capacities, the first two with 4 load stages, the other two with 2 load stages (1 size on line 1, 2 sizes on line 2). Two lines, line 1 with 4 scroll compressors, the first Digital Scroll™, line 2 with 4 reciprocating compressors, the first with inverter (1 size line 1, 2 sizes line 2). If an alarm is active on compressor 3, the recalculated activation thresholds are 10, 30, 70 %. C2 10% C4 30% 70% Regulation request Fig. 6.j Activation of the compressors and load stages may be: • Grouped (CpppCppp): first all the load stages are activated on one compressor before starting the next one • Balanced (CCpppppp): first all the compressors are started at minimum capacity and then the corresponding load stages are activated, one for each compressor, in sequence. 35 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG 6.3.3 Rotation with modulation devices Example 2: range of modulating device capacity variation lower than the capacity of the compressors: two compressors without capacity control, with the same capacity, 30 kW each, modulating device with variable capacity between 20 and 40 kW. It can be seen that the capacity delivered does not exactly follow the required capacity, rather acts in steps, so as to avoid swings. pRack pR300 can also manage compressor rotation when a capacity modulation device is fitted (inverter, Digital Scroll™ or continuous control). The type of modulating device is selected and the corresponding parameters set during the start-up procedure or in main menu branch C.a.f/C.b.f and C.a.g/C.b.g Actual capacity (kW) The modulating device is always the first to start and the last to stop irrespective of the type of rotation, the other devices start or stop according to the type of rotation selected. 100 80 Note: The compressor with modulation device is also assumed to be the first. 60 40 The trend in capacity delivered by the modulation device depends on the capacity of the compressor with the modulating device compared to the other compressors available. 20 Three cases can be identified: • compressors all with the same capacity and range of capacity variation of the modulating device greater than or equal to the capacity of the compressors • compressors all with the same capacity and range of capacity variation of the modulating device less than the capacity of the compressors • compressors with different capacities Regulation request Step compressors capacity Inverter capacity Total capacity Fig. 6.l Esempio 3: range of modulating device capacity variation in between the capacity of the compressors, all different sizes: two compressors without capacity control, capacities 15 kW and 25 kW, modulating device with variable capacity between 10 and 30 kW. In the first case, the modulating device manages to continuously cover the range of variation of the control request, while in the second case some discontinuous variations remain. The behaviour in the third case varies according to the capacities involved, and in any case reflects one of the two previous cases. Actual capacity (kW) 70 50 To configure the compressor capacity when an inverter is used, the minimum and maximum operating frequencies need to be set relating to the minimum and maximum value of the analogue output and the rated capacity delivered at rated frequency (50 Hz), so that the pRack pR300 software can calculate the capacity the compressor can deliver with the inverter and use this value for control. In addition, for inverters the variation in capacity delivered can be limited by setting the increase and decrease times. If these times have already been configured on the inverter, the higher time set has priority. 30 10 Regulation request Step compressors capacity Inverter capacity Total capacity Fig. 6.m Example 1: range of modulating device capacity variation higher than the capacity of the compressors: 6.3.4 Starting pRack pR300 can manage different types of compressor starting: • Direct • Part-winding • Star/delta two compressors without capacity control, with the same capacity, 20 kW each, modulating device with variable capacity between 30 and 60 kW. The figure shows the trend when the request sent by the controller increases and then decreases continuously between 0 and 100 %. It can be seen that the capacity delivered exactly follows the required capacity, except when below the minimum capacity of the modulating device. The type of starting can be selected and the related parameters set in main menu branch C.a.f/C.b.f. For part-winding starting, the delay in activating the digital output that controls the second winding needs to be set: Actual capacity (kW) 100 Compressor request 80 Line 60 40 Part-winding 20 Delay Regulation request Step compressors capacity Inverter capacity Total capacity Fig. 6.n For star/delta starting, the star time, the delay between the activation of the line and star digital input, and between the delta and star digital input all need to be set, as shown in the figure: Fig. 6.k pRack +0300025EN rel. 1.5 - 17.02.2020 36 ENG 6.3.8 Compressor request Line Part-winding Delta Star-line delay Delay Liquid injection As an alternative to the economizer, pRack pR300 can manage the injection of liquid into the compressors (the two functions are alternative, as the point of vapour injection into the compressor is the same). The function can be enabled and the related parameters set in main menu branch E.d.a.b/E.d.b.b. Liquid injection is used to protect the compressor, and in fact decreases the discharge temperature. Operation is Similar to the economizer function, with the difference that the expanded liquid is not sent to a heat exchanger, but rather directly into the compressor. The function is only activated when the compressor is on and the discharge temperature exceeds a set threshold (with differential). Start-delta delay Note: the function can be activated on a maximum of 6 compressors. Fig. 6.o 6.3.5 6.3.9 Safety times pRack pR300 can manage common safety times for each compressor: • Minimum on time: this is always considered, with the exception of when an alarm is activated that is configured to stop the compressor • Minimum off time • Minimum time between consecutive starts Enabling / disabling is managed in main menu branch C.a.f/C.b.f., while manual management and the output test can be activated in main menu branch B.b or B.c. In addition, pRack pR300 can manage the specific times for Digital Scroll™ compressors and screw compressors; for the descriptions see paragraphs 6.3.10 and 6.3.11. The related parameters can be set in main menu branch C.a.f/C.b.f. Enabling / disabling is used to temporarily exclude the compressors from operation, to allow, for example, repair or replacement. The disabled compressors are also excluded from rotation. Note: for two lines, a further delay can be set between starts of the compressors on different lines, so as to avoid Simultaneous starts. See paragraph 6.6.6 for the detailed description of the synchronisation function for two lines (DSS). 6.3.6 Note: enabling is the only compressor manual operating mode that can be activated when the unit is on. Both manual management and the output test are enabled by parameter and remain active for a set time after the last button is pressed, after which the unit returns to normal operating mode. Manual management is used to switch the compressors on or off without observing the control needs, however still considering any safety devices (alarms, safety times, starting procedures) and respecting the set configuration of the inputs/outputs. The activation screen resembles the one shown in the figure and is used to override the outputs relating to the operation of the selected device, e.g. compressor 1: Balancing pRack pR300 can control any balance valves in parallel with the compressors. This function can be used to activate a communicating solenoid valve between compressor suction and discharge, for a set time, before each individual compressor starts. In this way, the suction and discharge pressure can be balanced and the compressor can be started in more favourable conditions. The balancing function can be enabled and the related activation time set in main menu branch C.a.f/C.b.f. 6.3.7 Manual operation pRack pR300 can manage 3 different compressor manual operating modes: • Enabling / disabling • Manual management • Output test Economizer pRack pR300 can activate the economizer function to boost compressor efficiency by injecting vapour. Some of the liquid is taken from the condenser, expanded through a valve and then sent to a heat exchanger to cool the liquid leaving the condenser. The resulting superheated vapour is injected into a special section of the compressor. The economizer function is enabled by going from the main menu to “Other functions”à “Economizer” à “Settings”. Screens Ecab05 onwards are used to modify the economizer function activation parameters. The output test is used to activate or deactivate the outputs (where necessary setting an output percentage for the analogue outputs), without observing any type of safety feature. The activation screen resembles the one shown in the figure and is used to override the outputs on the pRack boards, in the order they physically appear on the board (without links to the devices): The economizer is only efficient for high compressor activation capacities, typically over 75 %, therefore the economizer function control valve is only activated when exceeding a set threshold. As the economizer tends to increase the condensing pressure, this needs to be controlled to ensure the high condensing pressure alarm is not generated. In addition, the injection of vapour decreases the discharge temperature and so this value also needs to be monitored. Consequently, the three conditions for activation of the economizer function are: • Capacity above a set threshold • Condensing pressure below a set threshold (with reset differential) • Discharge temperature above a set threshold (with reset differential) Note: the function can be activated on a maximum of 6 compressors. Important: manual mode and the output test can only be activated with the unit off. Both manual mode and above all the output test must be used with special care and by expert personnel to avoid damage to the devices. 37 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Starting procedure pRack pR300 can manage the specific starting procedure for Digital Scroll™ compressors, as represented as in the following figure: 6.3.10 Digital Scroll™ compressors pRack pR300 can use a Digital Scrollä compressorä as the modulating device for suction lines (one for each line). This type of compressor features special operation, and is controlled by pRack pR300 as follows. The related parameters can be set in main menu branch C.a.f/C.b.f. The capacity is modulated by opening/closing a valve with PWM; when the valve is ON the compressor delivers minimum capacity, while when the valve is off the compressor delivers maximum capacity. In the following description and figure, ON and OFF refer to the status of the compressor, while operation of the valve is the exact opposite: 4s 50s 100s Valve Compressor Startup Compressor PWM modulation 10% 13s 10s 15s 15s Fig. 6.q There are three stages: 1. balance: the PWM valve is activated for 4 s, so that the compressor delivers minimum capacity; 2. compressor activation with 50 % capacity for 3 minutes; 3. forced operation at 100 % for 1 minute. 5s During the starting procedure, the request sent by the controller is ignored and only at the end of the procedure does the capacity delivered start reflecting the request. If the request is cancelled during the starting procedure, the compressor stops at the end, then the min. ON time for these types of compressors is set to 244 s. The starting procedure is performed when the compressor is started, while it can be disabled for a set time by parameter for subsequent starts, if the compressor has not remained off for a minimum set time. After this time has elapsed the procedure is performed again during the following start. Variable cycle time 18s 8s 20s time 67% Fixed cycle time ON OFF 2s 60s Request Compressor power request ON OFF 2s 180s 4s 12s Fig. 6.p The following data are provided by the manufacturer of the compressor: • minimum ON time 2 s • maximum cycle time 20 s • optimum cycle time 12 s Note: the safety times for Digital Scroll™ compressors are established by the manufacturer, and are as follows: • Minimum ON time: 244 s (starting procedure) • Minimum OFF time: 180 s • Minimum time between restarts: 360 s There are three possible operating modes: • Fixed cycle time • Variable cycle time • Optimised cycle time Alarms pRack pR300 can manage, in addition to the common alarms for all types of compressors (see chapter 8 for details), some specific alarms for Digital Scroll™ compressors: • high oil temperature • oil dilution • high discharge temperature These alarms are managed as specified by the manufacturer of the compressor, and therefore pRack pR300 can only enable or disable them. Activation of these alarms requires an oil temperature probe, which can also be the common probe (see the paragraph relating to oil management) and the compressor discharge temperature probe. Based on the operating mode selected, pRack pR300 calculates the valve activation percentage that satisfies the required capacity. Fixed cycle time The compressor ON time is calculated as the percentage of the cycle time corresponding to the required capacity: TON= % Request * Cycle Time The cycle time can be set to the optimum value suggested by the manufacturer to achieve maximum COP, or to a higher value to increase resolution of the capacity delivered (a higher cycle time implies greater continuity in the effective capacity that can be delivered). Note: pRack pR300 does not manages the envelope for Digital Scroll™ compressors and consequently there is no corresponding alarm when operating outside the envelope. Variable cycle time The compressor ON time is set to 2 s and the cycle time is calculated based on the required capacity: 6.3.11 Screw compressors TCYCLE= TON /% Request pRack pR300 can manage up to two screw compressors, with control in stages or continuous control (only the first compressor with continuous control, used as modulation device for the suction line), which can be a generic device or pre-configured in accordance with the most common devices supplied by the main manufacturers. Advanced functions are also available, for example envelope control, described further on. The parameters relating to screw compressors can be set in main menu branch C.a.f/C.b.f. Screw compressors are fitted with up to 4 capacity control valves (hereinafter V1, V2, V3, V4), which can have 4 types of behaviour: • X à OFF: the valve is closed; • O à ON: the valve is open; • I à Intermittent: the valve is opened/closed intermittently (approximately every 10-15s); • P à Pulsating: the valve is opened/closed alternately with very rapid opening/closing times (approximately every 1-2 s). Optimised cycle time The compressor ON time is set to 2 s and the cycle time is calculated based on the required capacity for capacities less than 17 %, after which the cycle time is set to 12 s and the ON time varies. In essence, this mode is a combination of the previous two. This guarantees the maximum possible COP and control rate (obtained with the 12 s cycle time) and the maximum control range (starting from 10 %). Note: • the minimum capacity that can be delivered by Digital Scroll™ compressors is Minimum ON time/Maximum cycle time = 2/30 = 6.7 %, which also depends on the selected control mode (for example, in the first case shown in the figure the minimum capacity delivered is Minimum ON time/Cycle time = 2/15 = 13%). • if high pressure prevention is enabled with activation/deactivation Important: pulsating valves must be associated with an SSR relay output, to avoid damage. of the devices, the Digital Scroll™ compressor delivers the minimum possible capacity. V1, V2, V3 and V4 can be managed to obtain stage or continuous compressor control. pRack +0300025EN rel. 1.5 - 17.02.2020 38 ENG Stage control For the control in stages, normally involving four load stages, 25, 50, 75, 100 %, a table needs to be created that shows the behaviour of each valve in the different conditions (starting, 25 %, 50 %, 75 %, 100 %). The figure shows one possible example: Envelope For screw compressors, pRack pR300 can manage control of the envelope, which can either be pre-set or defined by the user. pRack pR300 accepts the envelope control settings for the Bitzer CSH series compressors, and these simply need to be enabled in main menu branch C.a.g. For all other series of compressors, the envelope can be managed by enabling and setting all the related parameters in main menu branch C.a.g. The following parameters need to be set in order to manage the envelope: • Definition of the points (maximum 30) • Definition of the zone (maximum 12). Each zone can be made up of one or more polygons (total maximum 14, which must be closed and convex) • Definition of the behaviour of the compressor in the different zones (capacity and duration) If intermittent valves are used, the cycle time also needs to be set. Note: normally operation at minimum capacity (25 %) is only possible for a limited time, after which the compressor must switch to the next stage. This function can be enabled and the corresponding time can be set. The meaning of the parameters is shown in the figure: Discharge pressure P1 P2 P3 (Pol. 2) Continuous control For continuous control, a table needs to be created that shows the behaviour of each valve in the different conditions (start/stop, increase, decrease, standby). The figure shows one possible example: Zone 2 P4 (Pol. 3) Zone 1 (Pol. 1) P5 P6 P7 P8 Suction pressure Fig. 6.r pRack pR300 can also manage the variation in the envelope as the capacity delivered changes, for example in the case of variation in frequency for inverter-driven compressors. If intermittent/pulsating valves are used, the cycle time also needs to be set. Intermittent valves are opened/closed for 50 % of the set time, while for pulsating valves the opening and closing time in theory depend on the difference between the position of the slide and the capacity request. As the position of the slide is generally not measurable, the variation in the request is used to calculate the times for pulsating valves. Note: for further details on configuration of the envelope, contact Carel. 6.3.12 Bitzer CRII modulating compressor pR300 can manage a system fitted with CRII compressors. Up to 2 CRII compressors can be configured (one on each line), each as first compressor in L1 and L2. CRII is set as a capacity controlled piston compressor in which the capacity steps can be activated/deactivated rapidly (5 s). In addition, the CRII compressor can be ON with the capacity steps deactivated, so as to respond faster to demand. This condition can remain active for a maximum set time, after which capacity control will be activated, in turn for a set time, to prevent compressor malfunctions. Compressor capacity control is achieved by valves managed using SSR digital outputs, due to the high number of cycles involved. Up to 3 capacity steps can be configured on for each line (check the number of SSRs available). Management by the pR300 of the different capacity steps allows complete compressor capacity modulation. Note: in continuous control, operation is normally only allowed for an undetermined time when the capacity exceeds 50 %. Starting procedure pRack pR300 can manage the starting procedure for the screw compressors by considering, following the star/delta or part-winding starting selected, a further time of operation at minimum capacity, established by the manufacturer or set to 60 s for generic compressors. Once the starting procedure has ended, the compressor starts varying the capacity according to the control request and if necessary considering the duration at minimum capacity. Series of compressors supported pRack pR300 can manage several series of screw compressors made by the main manufacturers, (Bitzer, Refcomp, Hanbell, …) which come with the parameters described above already set. If the maximum number of starts in one hour (equal to 8) is reached, compressor capacity will be forced to 0% and the message “! 8-” will be shown. The models managed by pRack pR300 are shown in the table: Capacity-control activation/deactivation Capacity-control refers to the valve installed on the compressor. For 2 capacity steps, the compressor will be fitted with 2 valves and pRack needs to manage 2 SSR digital outputs. Capacity-control activation/deactivation refers then to energising/de-energising the valve, so as to open or close the flow of refrigerant. A step is activated when demand exceeds the corresponding capacity, vice-versa it is deactivated when demand falls to the lower step. The following figure represents an example of a CRII with 2 capacity steps (50-100). Manufacturer Model Bitzer CSH65…95, HS.53-4/64, HS.74, HS85 Hanbell RC2-100/140/180, RC2-170/200…1520 134-S, 134-XS L1, 134-XS L2, SRS-S1XX…755, SRC-S785…985, RefComp SRC-XS L1, SRC-XS L2 Tab. 6.e For manufacturers or series of compressors that are not supported, the generic type can be used and the corresponding parameters set as described previously.. The first steps is activated as soon as demand exceeds 50%, and the second when reaching 100%. When demand falls, on the other hand, the second step is deactivated as soon as this falls below 50%, and the first at 0%. Note: for further details on the series of compressors supported and the related pre-configured parameters, contact Carel. 39 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG If it is the last compressor active at that moment, after reaching 0% capacity it will immediately shut down. 150 100 50 0 50 100 Rising (%) Falling (%) 150 -50 Configuration A system with CRII compressors can be configured directly from the wizard. The following procedure shows the selection of a CRII compressor with two capacity steps, 50%-100%: Fig. 6.s CRII modulation in neutral zone The type of control can be selected between proportional-integral and neutral zone. If choosing neutral zone control, CRII compressor modulation can be enabled inside the zone. CRII modulation requires the definition of a new band, comprising the set point and a differential called “Diff CRII”, this band defined must fall inside the neutral zone. CASE 1: suction pressure is inside the neutral zone and is increasing. Starting from current capacity, at the moment when “min mod” is exceeded, the compressor will activate the capacity steps until reaching “max mod” at 100%. CASE 2: suction pressure is inside the neutral zone and is decreasing. Starting from current capacity, at the moment when “min mod” is exceeded, the compressor will deactivate the capacity steps until reaching “max mod” at 0%. min mod. Times Min Ton, minimum ON time: • 120 s up to 5.5kW • 180 s up to 15kW • 300 s above 15kW max mod. diff CRII diff CRII Min Toff, minimum OFF time: • range [5 s … 999 s] Psuct diff NZ Min start same compressor, minimum time between two consecutive starts of the same compresso: • range [ 5 s … 999 s] diff NZ Set point Fig. 6.ap Legenda: ® MIN mod. = actual capacity CRII MAX mod. = 100% capacity ¬ MAX mod. = actual capacity CRII MIN mod. = 0% of CRII Total capacity doesn’t change Max time with compressor on with load bypassed is the maximum time in which the CRII compressor can remain active at 0% capacity after which capacity control will be activated. • up to 120 s In both cases, in the grey area between the neutral zone thresholds and the CRII differentials, total capacity does not change. Note: when the suction pressure falls outside of the neutral zone, the compressors are switched off in sequence, varying CRII capacity to achieve correct modulation. The CRII compressor will go to 0% capacity before another compressor is shut down, and can remain in this condition for a set time, as long as there are other active compressors. pRack +0300025EN rel. 1.5 - 17.02.2020 40 ENG CRII unloader delay is the delay on activation of capacity control. • range [5 s … 999 s] The following table highlights the cases in which the fan is activated with reference to the default values, with 3 capacity steps: Condensing CRII % activation(*) Fan activation pressure (Pcond) Pcond<P1 (condi- OFF Keep off or switch off after 0s + 20s tion not allowed) P1<=Pcond<P2 step1 ® 0% Switch on P2<=Pcond<P3 step1 ® 0% Switch on Pcond>=P3 step1 ® 0% Switch on P1<=Pcond<P2 0% Keep on P2<=Pcond<P3 0% Keep on Pcond>=P3 0% Keep on P1<=Pcond<P2 step2 ® step1 Keep off or check step1 switch off condition P2<=Pcond<P3 step2 ® step1 Switch on Pcond>=P3 step2 ® step1 Switch on P1<=Pcond<P2 step1 Keep off or switch off after 60 s + 20s P2<=Pcond<P3 step1 Switch on Pcond>=P3 step1 Switch on P1<=Pcond<P2 Step3 ® step2 Keep off or check step2 switch off condition P2<=Pcond<P3 Step3 ® step2 Keep off or check step2 switch off condition Pcond>=P3 Step3 ® step2 Switch on P1<=Pcond<P2 step2 Keep off or switch off after 60 s + 20s P2<=Pcond<P3 step2 Keep off or switch off after 180 s + 20s Pcond>=P3 step2 Switch on P1<=Pcond<P2 step3 Keep off or switch off after 60 s + 20s P2<=Pcond<P3 step3 Keep off or switch off after 180 s + 20s Pcond>=P3 step3 Switch on Extra cooling fan To prevent malfunctions of the CRII compressor due to high operating temperature, pR300 can activate a fan installed on the compressor to provide extra cooling. pR300 does not manage the CRII compressor envelope. The extra cooling fan is activated based on two variables: • Current CRII capacity • Condensing pressure with specific cases for the medium temperature and low temperature line. Fan for medium temperature line The following parameters need to be set to manage the fan: • Condensing pressure threshold (default 16 bars) • Shutdown evaluation time with pressure higher than threshold(default 180 s) • Shutdown evaluation time with pressure lower than threshold(default 60 s) • Shutdown delay (default 20 s) 6.4 Fans pRack pR300 can manage up to 2 condenser lines with up to 16 fans and one speed modulation device each, applying common types of device rotation and controlling both the starting mode and some accessory functions. The modulation device may be an inverter or a phase fired controller. The fan functions and related parameter settings are enabled from main menu branch D.a/D.b. The functions are described in detail below. 6.4.1 Control pRack pR300 can manage - as described in paragraph 6.2 - proportional band and Neutral zone control, by pressure or temperature. For details on the control modes, see the corresponding paragraph, while below is the description only of the features relating to the fans. The following table highlights the cases in which the fan is activated with reference to the default values: Condensing CRII % activation (*) Fan pressure (Pcond) Pcond >= 16bar 50% ® 0% Switch on Pcond < 16bar 50% ® 0% Keep off or switch off after 0s + 20s Pcond >= 16bar 0% Keep on Pcond < 16bar 0% Keep off or switch off after 60 s + 20s Pcond >= 16bar 50% Keep off or switch off after 180 s + 20 s Pcond < 16bar 50% Keep off or switch off after 60 s + 20 s Fan operation depending on the compressors The operation of the fans can be bound to the operation of the compressors by setting a parameter in main menu branch D.a.b/D.b.b, in this case the fans only start if at least one compressor is on. This setting is ignored if the fans are controlled by a dedicated pRack pR300 board and the pLAN network is disconnected. Fan for low temperature line The following parameters need to be set to manage the fan: • Condensing pressure threshold P1 (default 7.5 bars) didepending on the capacity step • Condensing pressure threshold P2 (default 15 bars) didepending on the capacity step • Condensing pressure threshold P3 (default 19.5 bars) didepending on the capacity step • Shutdown evaluation time with pressure higher than threshold(default 180 s) • Shutdown evaluation time with pressure lower than threshold(default 60 s) • Shutdown delay (default 20 s) Fan operation with modulating device If the fans are controlled by a modulating device, the meaning of the parameters that associate the minimum and maximum values of the device’s modulating output and the minimum and maximum capacity of the modulating device on screens Dag02 and Dbg02 is illustrated in the following examples. Example 1: minimum modulating output value 0 V, maximum value 10 V, minimum modulating device capacity 0 %, maximum 100 %. Analog output Max capacity = 100 % Max output value = 10 V Min capacity = 0 % Min output value = 0 V Setpoint Differential Differential Regulation probe value Fig. 6.t 41 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Example 2: minimum modulating output value 0 V, maximum value 10 V, minimum modulating device capacity 60 %, maximum 100 %. If there is more than one inverter driven fan, as well as being able to use an alarm digital input for each, it is assumed that the weight of the modulating device is proportional to the number of fans, therefore the first case is applied, as described in paragraph 6.3.3: fans all with the same power and modulating device power variation range greater than or equal to the capacity of the other devices. Analog output Max capacity = 100 % Max output value = 10 V Example 1: 4 fans all controlled by the same inverter correspond to 1 fan with four times the power. Min output value = 0 V Min capacity = 60 % Setpoint Differential Differential Note: some fans can be excluded from the rotation, for example in the winter; to do this use the split condenser function described in paragraph 6.4.5. Regulation probe value 6.4.3 Fig. 6.u Example 3: minimum modulating output value 2 V, maximum value 10 V, minimum modulating device capacity 60 %, maximum 100 %. The function can be enabled and the related parameters set in main menu branch D.a.g/D.b.g Analog output Max capacity = 100 % Max output value = 10 V If speed up is enabled, a start time can be set in which the fan speed is forced to 100%. If the outside temperature sensor is used, moreover, a threshold can be set (with reset differential) below which speed up is disabled, so as to not drastically lower the condensing pressure at start-up. Min capacity = 60 % Note: speed up has lower priority than the Silencer function (see the following paragraph for the details), therefore if the Silencer function is active, this is disabled. Min output value = 2 V Setpoint Differential Differential Fast start (speed up) pRack pR300 can manage the fast start function (speed up), used to overcome the initial inertia of the fans. Regulation probe value 6.4.4 Silencer pRack pR300 can manage the Silencer function, used to limit fan speed at certain times of the day or in specific conditions, enabled by digital input. The function can be enabled and the related parameters set in main menu branch D.a.g/D.b.g. Enabling fan speed limitation from the digital input or based on time bands is independent, consequently the speed is limited to the set value when at least one of the two conditions is active. Up to 4 activation bands can be set for each day of the week. Fig. 6.aq Cut-off pRack pR300 manages a control cut-off for the fans; functions and related parameter settings can be enabled from main menu branch D.a.b/D.b.b. The operating principle of the cut-off function is shown in the figure: Regulation request 6.4.5 Max output value Split condenser pRack pR300 can manage the possibility to exclude some fans from operation, for example to reduce condenser operation in winter, using the split condenser function. The function can be enabled and the related parameters set in main menu branch D.a.g/D.b.g. Cut-Off value of request Cut-Off setpoint Regulation setpoint Differential Differential Split condenser can be used to exclude from rotation fans whose index is: • even • odd • higher than a settable value • lower than a settable value Regulation probe value Fig. 6.v A percentage of the control request and a cut-off set point can be set. When the control request reaches the set cut-off value, this value is kept constant until the control value falls below the cut-off set point, after which it falls to 0 % and remains there until the request exceeds the cut-off value again. The function can be activated by: • time bands (winter/summer seasons) • digital input • supervisor • outside temperature (set threshold and differential) 6.4.2 • the split condenser function can be disabled by parameter if the high Note: Rotation pressure prevention function is activated (see paragraph 8.3.3). If split condenser is disabled due to activation of the high pressure prevention function, it remains disabled for a set time, after which it is reactivated. • split condenser cannot be enabled if there is a speed modulation device that controls all the fans. pRack pR300 can manage rotation of the fans, much in the same way as described for the compressors, therefore: • LIFO, FIFO, time, Custom rotation • Management of a modulation device on each line The substantial difference compared to the compressors concerns the possibility to manage different capacities and load stages, which are obviously not featured for the fans. In addition, pRack pR300 can specially manage inverter driven fans. In fact, a multiple number of inverter driven fans can be set. If there is more than one fan, however the number of inverter driven fans is set to 1, the fans are started and stopped at the same time, and the fans will always all be at the same power. pRack +0300025EN rel. 1.5 - 17.02.2020 42 ENG 6.4.6 Compensation from analogue input only applies to the suction pressure set point and can be enabled separately. If compensation from analogue input is enabled, a offset that is linearly variable to the value read by a dedicated probe can be applied to the suction pressure set point, as shown in the figure. Manual operation pRack pR300 can also manage the same three manual operating modes for the fans as described for the compressors: • Enabling • Manual management • Output test Offset Enabling is managed in main menu branch D.a.f/D.b.f., while manual management and the output test can be activated in main menu branch B.b or B.c. For the detailed description of the three modes, see paragraph 6.3.9. Offset max 6.4.7 Offset min Alarms Probe value pRack pR300 can manage both a common alarm for the fans and separate alarms for each fan. When the common alarm is active the alarm is signalled, but no fan is stopped, while for separate alarms the fan that the alarm refers to is stopped. For details on the fan alarms, see Chapter 8. Lower value 6.5.2 Floating suction pressure set point For the suction line, the floating set point is managed by the supervisor. The suction pressure set point set by the user is changed by the supervisor in range between a settable minimum and maximum. The operation is illustrated in the following figure: 6.5 Energy saving pRack pR300 can activate energy saving functions by adjusting the suction and condensing pressure set points. The suction and condensing pressure set points can be applied with two different offsets, one for the closing period and one for the winter period, activated by: • Digital input • Time band • Supervisor Floating setpoint Max Real variation In addition, the suction pressure set point can be modified from analogue input, applying a linearly variable offset based on the value read by a probe. As well as set point compensation from digital input, scheduler, supervisor or analogue input, two further energy saving functions are available, floating suction and condensing pressure set point. The functions can be enabled and the related parameters set in main menu branch C.a.d/C.b.d and D.a.d/D.b.d. 6.5.1 Upper value Fig. 6.x Max variation Min time Sampling time Set point compensation Fig. 6.y Compensation from digital input, scheduler or supervisor is similar for the suction and condensing pressure set points, consequently the following description applies to both. The set point is calculated by the supervisor and acquired by the pRack pR300 controller at set intervals, the maximum variation allowed for the set point in each sampling period can also be set; if the value acquired differs from the previous value by more than the max. variation allowed, the variation is limited to the maximum value. If the supervisor is disconnected, after 10 min. (fixed) the pRack pR300 controller starts decreasing the set point with variations equal to the maximum variation allowed each sampling period, until reaching the min. set point allowed with floating suction pressure. Two different offsets can be defined, which apply to: • Closing periods, defined by the scheduler, activation of a digital input or supervisor • Winter period, defined by the scheduler The two offsets add to the set point defined by the user when the corresponding condition is active. Note: if set point compensation from scheduler, digital input or supervisor is also active, the offset is added to the minimum and maximum limits for the floating set point. Example 1: closing offset 0.3 barg, winter offset 0.2 barg, suction pressure compensation from scheduler and from digital input activated. When the digital input is activated, for example with a day/night function, 0.3 barg is added to the operating set point, and when the winter period is in progress a further 0.2 barg is added. The operation can be schematised in the following figure: 6.5.3 Floating condensing pressure set point For the condenser line, the floating set point is based on the outside temperature. The floating condensing pressure set point is achieved by adding a constant programmable value to the outside temperature and limiting the resulting value between a settable minimum and maximum, as shown in the figure: Digital Input ex.: day/night Summer/Winter Floating setpoint Max Setpoint User setpoint +0,5 barg offset time Min Fig. 6.w external temperature Note: the same digital input is used for set point compensation on each line, so if suction and condensing pressure set point compensation is activated by digital input, both compensation functions are active at the same time. time Fig. 6.z Note: if set point compensation from scheduler, digital input or supervisor is also active, the offset is added to the minimum and maximum limits for the floating set point. 43 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Line oil management pRack pR300 features an alarm digital input for each line; this is with Signal only, that is, has no effect on the operation of the devices. For details on this alarm see chapter 8. For all types of compressors, a common oil cooler can be managed for each line; the operation of this is Similar to the cooler for each individual compressor described previously. 6.6 Accessory functions pRack pR300 can manage several accessory functions. Of these, the economizer and liquid injection have already been described in paragraph 6.3 on compressor operation, while the others are described below. 6.6.1 Oil management Note: for screw compressors, if common cooling is selected, cooling for each compressor cannot be activated. pRack pR300 features oil management for the individual compressors, as well as common management for each line: • Individual compressor: oil alarm, high oil temperature, and, for screw compressors only, oil warning, oil cooling and oil level • Line: common oil alarm, high oil temperature warning, oil cooling The function can be enabled and the related parameters set in main menu branch E.a.a/E.a.b or C.a.e/C.b.e (for the individual compressor alarms). 6.6.2 Subcooling pRack pR300 can control subcooling in two different ways: • with the condensing temperature and the liquid temperature • with the liquid temperature only In the first case, subcooling is calculated as the difference between the condensing temperature (obtained by converting the condensing pressure) and the liquid temperature measured after the exchanger. The corresponding output is activated below a set threshold, with fixed differential. Individual compressor oil management For the description of the oil alarm and warning corresponding to the individual compressor see Chapter 8. For screw compressors, an oil cooler can be managed for each compressor, made up of a heat exchanger, a fan and 1 or 2 pumps. The operation of the cooler varies according to the setting of the output, which may be: • Analogue: one pump only • Digital: 1 or 2 pumps Digital output The control probe is the compressor oil temperature probe, and the following need to be set: set point, differential and, for 2 pumps only, an activation delay for the second pump. The operation of the cooler when using an analogue output is shown in the figure: 1°C/°F Threshold Fig. 6.ac Fan Oil cooler 0...10 V Tcond. - Tliq. In the second case, the output is active for liquid temperature values greater than a threshold, with fixed differential. Digital output Pump Differential Differential 1°C/°F Oil temperature Threshold Setpoint Fig. 6.ad The subcooling function can be enabled and the related parameters set in main menu branch E.b.a/E.b.b. Fig. 6.aa If a digital output and just one pump is used, the fan and the pump are activated/deactivated at the same time: Note: the subcooling func. is active when at least one compressor is on. 6.6.3 Oil cooler 0...10 V Differential Heat recovery pRack pR300 can manage heat recovery for types of system with heat recovery in series with the main condenser. Heat recovery can be activated by: • Probe • Time bands • Supervisor Fan/Pump Differential Tliq. Oil temperature Setpoint The heat recovery function can be enabled and the related parameters set in main menu branch E.e.a/E.e.b. A digital input is managed that acts as a trigger for activating the function. When the digital input is not active, heat recovery is not operating, while when the digital input is active heat recovery is operating when at least one of the other conditions is true, as shown in the figure: Fig. 6.ab If a digital output and two pumps are used, the operation of the fan and the first pump is Similar to the previous case, while the second pump is activated when the oil temperature is greater than the set point + differential for a time at least equal to the delay, and is deactivated when the oil temperature falls back below the set point minus the differential. The oil level can be managed for the first 6 compressors on each suction line. If a compressor alarm is configured as an oil alarm, this alarm can be associated with oil level management, enabling the function and setting the compressor alarm number to be used: when the digital input associated with the alarm is activated (this thus Signals the low oil level), a valve is activated with intermittent operation to restore the level, with opening and closing times that can be set. If after a set time, the digital input is still active, that is, the minimum level has not been reached, pRack pR300 Signals an alarm and stops the compressor. Digital Input Probe Scheduler Supervisor Heat reclaim Fig. 6.ae pRack +0300025EN rel. 1.5 - 17.02.2020 44 ENG The generic functions can be enabled and the related parameters set in main menu branch E.f. To be able to use the free inputs, these must be configured as generic probes from A to E (analogue inputs) and generic inputs from F to J (digital inputs), consequently a maximum of 5 analogue and 5 digital inputs can be used. After having configured the generic probes, the associated variables can be used as control variables and the digital inputs as enabling variables. If the digital input is not configured, only the other conditions are taken into consideration. When the heat recovery function is active, a digital output is activated to trigger the pump and a digital or analogue output for an On/Off or modulating 3-way valve. For activation by probe, the operation of the On/Off or modulating 3-way valve and the pump is shown in the figure, where the temperature considered is the heat recovery exchanger outlet temperature: Heat reclaim by probe Pump and ON/OFF valve As well as the generic probes and inputs, pRack pR300 software internal variables can be used, depending on the system configuration. Some examples are, for analogue variables: • Suction pressure • Condensing pressure • Saturated suction temperature • Saturated condensing temperature • Suction temperature • Discharge temperature • % of compressors active • % of fans active • Superheat • Subcooling • Liquid temperature, • % compressor request • % fan requesti Modulating valve Differential Differential Setpoint Outlet temperature (Refrigerant) Fig. 6.af If the probe is not working, pRack pR300 considers the other conditions, without Signalling further alarms in addition to the probe alarm. As regards activation from time bands, heat recovery does not consider the operating seasons, and links can be set to special days and closing periods so that heat recovery is only active based on the daily bands set. And for the digital variables: • High suction pressure alarm • Low suction pressure alarm • High condensing pressure alarm • Sign of life • Prevent active Note: • a settable bottom limit is available for the condensing pressure, below which heat recovery is deactivated. Each generic function can be associated with a unit of measure and a description. Below is a description of the operation of four types of generic functions. • condensing pressure set point compensation can be disabled when heat recovery is active.. Heat recovery as the first stage in high pressure prevention Heat recovery can be used to prevent high condensing pressure. The parameters relating to this function can be set in branch G.b.a/G.b.b of the main menu, after having enabled the heat recovery function. For details on operation of the prevent function, see paragraph 8.3.3. Heat recovery operation as the first stage in high pressure prevention is shown in the figure: Heat reclaim For both the “Stage” and “Modulating” generic functions, it is possible to choose whether to set the generic function on one or two distinct control variables. In the latter case, it is possible to link the two control variables by enabling one of the following operations between them: • DIFFERENCE = Var1 – Var2 (default) • AVERAGE = (Var1+Var2)/2 • SUM = Var1 + Var2 • RATIO = Var1 / Var2 (e.g. compression ratio = Pdisch_L1 – Psuct_L1) Prevent The following options are therefore now available: • Control on a single variable: Diff. Diff. Diff. Diff. Cond. Press. Offset Heat reclaim activation Prevent threshold Fig. 6.ag The function must be enabled and an offset must be set in relation to prevent threshold, while the differential is the same set for the prevent function. 6.6.4 Generic functions pRack pR300 can use the free inputs /outputs and certain internal variables for generic functions. Important: The generic functions are available on pRack pR300 boards with pLAN addresses from 1 to 4, that is, on all boards that manage a suction or condensing line, nonetheless only the parameters corresponding to the functions managed by boards 1 and 2 are sent to the supervisory system. The following generic functions are available for each board: • 5 stages • 2 modulations • 2 alarms • 1 scheduler 45 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG • Control on two variables: be set. See chapter 8 for details on the alarms. One example of using the generic stage functions may be activation of the fans on the room units based on the temperature. Modulation pRack pR300 can manage up to 2 modulation functions, with either direct or reverse operation. In both cases, a set point and a differential can be set; the operation of the corresponding output is shown in the figure for direct mode, with the cut-off function also enabled: Direct modulation MAX MIN (Cut-off Value) Note that the second control variable can be selected after having configured the first. If both variables are configured, and then the first one is removed, the second is automatically reset. Hyster. Setpoint Regulation variable Differential Fig. 6.ai Note: the control variables selected must be dimensionally coherent. This means that operations are only permitted between uniform variables (e.g. pressure with pressure, temperature with temperature, etc.). If the control identifies an inconsistency between the two variables, the second control variable is automatically reset (see the figures below). If an enabling variable has been set, the corresponding output is active if the enabling is also active. For each modulation, a high alarm threshold and a low alarm threshold can be set, and are absolute. For each alarm, the activation delay and priority can be set. See chapter 8 for details on the alarms. For modulation a minimum and maximum value can also be set for the output, and the cut-off function can be enabled, with operation as shown in the previous figure. For the “Modulating” generic functions, in addition to the PROPORTIONAL setting, the PID (proportional + integral + derivative) setting has also been introduced (from version 4.1.0). Stages pRack pR300 can manage up to 5 stage functions, with either direct or reverse operation. In both cases, a set point and a differential can be set; the operation of the corresponding output is shown in the figure for both cases: Direct stage Diff. Diff. PID control is available in both “direct” and “reverse” mode. In the same way as for proportional control: • in direct mode, the analogue output increases as the value of the control variable increases; • In reverse mode, the analogue output increases as the value of the control variable decreases. Regulation variable Setpoint Once PID control has been selected, in addition to the proportional gain (defined by the differential), the integral and derivative times can also be set (see the figure below). Reverse stage Diff. Diff. Regulation variable Setpoint Fig. 6.ah If an enabling variable has been set, the corresponding output is active if the enabling is also active. For each stage, a high alarm threshold and a low alarm threshold can be set, and are absolute. For each alarm, the activation delay and priority can pRack +0300025EN rel. 1.5 - 17.02.2020 46 ENG The four DSS functions can be enabled independently and are useful for booster or CO2 cascade system configurations: Alarms pRack pR300 can manage up to 2 alarm functions, with settable digital variable to be monitored, activation delay, priority and description. Each generic function can be associated with a digital output for the activation of external devices when the alarm is activated. One example of using the generic alarm functions involves detecting gas leaks. Scheduler pRack pR300 can manager a generic scheduler that activates a digital output at certain time bands. Up to 4 daily time bands can be set for each day of the week, in addition operation of the generic scheduler can be linked to the common scheduler, and consequently the output activated based on: • summer/winter • up to 5 closing periods • up to 10 special days See paragraph 6.7.2 for details on the time bands. 6.6.5 P T P T Fig. 6.aj ChillBooster pRack pR300 can control the Carel ChillBooster, device used for evaporative cooling of the air that flows through the condenser. ChillBooster can be enabled and the related parameters set in main menu branch E.g. ChillBooster is activated when two conditions exist: • the outside temperature exceeds a set threshold • the fan control request is at the maximum for at least a settable number of minutes The maximum request time starts counting again whenever the request decreases, therefore the request must remain at the maximum for at least the set time. Activation ends when the request falls below a set threshold. pRack pR300 can manage an alarm digital input from ChillBooster, the effect of which is to deactivate the device. For details see Chapter 8. As the number of operating hours of ChillBooster is critical as regards formation of scale on the condenser, pRack pR300 can manage the operating hour threshold, which should be set to 200 hours. P T P T P T Fig. 6.ak Hygiene procedure To avoid water stagnation in the pipes, a hygiene procedure can be enabled that activates ChillBooster every day for a set time, if the outside temperature is greater than a threshold. Important: in the pRack pR300 software assumes that the medium temperature line is line L1, while the low temperature line is line L2. DSS can be enabled and the related parameters set in main menu branch E.h. Note: if the outside temperature probe is not configured or is configured but is not working, ChillBooster operates based solely on the control request, and the hygiene procedure can still be activated. Disable simultaneous starts Disabling simultaneous compressor starts may be useful for all system configurations with two separate lines and in cascade system configurations. The function to avoid simultaneous starts can be enabled, setting a delay time between the starts of compressors on different lines. The only difference between probe not configured and probe not working concerns the ChillBooster operating without temperature probe alarm, which is only generated when the probe is configured but not working. ChillBooster as the first stage in high pressure prevention ChillBooster can be used to prevent high condensing pressure. Forcing the medium temperature line Forcing the medium temperature line may be useful for cascade system configurations and involves, once enabled, forcing at least one compressor on medium temperature line L1 to start at minimum capacity, if at least one compressor on low temperature line L2 is running. This means that before the low temperature line starts, the DSS function forces at least one of the compressors on medium temperature line L1 to start. The low temperature line L2 thus has higher priority than the control request for medium temperature line L1. The parameters relating to this function can be set in branch G.b.a/G.b.b in the main menu, after having enabled the ChillBooster function. For details on the prevent function see paragraph 8.3.3. Operation of ChillBooster as the first stage in high pressure prevention is Similar to the heat recovery function described in paragraph 6.6.3. The function must be enabled and an offset must be set in relation to the prevent threshold, while the differential is the same as set for the prevent function. 6.6.6 Shutdown the low temperature line The low temperature line is shutdown by the DSS function if a serious alarm is activated on the medium temperature line, or, in general, if the medium temperature line is OFF. Double line synchronisation (DSS) pRack pR300 can manage, for two line configurations, several synchronisation functions between the two lines: • Disable simultaneous compressors starts • Force the medium temperature line on if the low temperature line is activated • Shutdown the low temperature line if the medium temperature line has a serious alarm • Enable pump-down medium temperature line Enable pump-down medium temperature line During normal compressor rack operation, when at least one compressor on the low temperature line is running, the medium temperature compressor control will enable pump-down. If there is demand on the low temperature line, the minimum capacity step for medium temperature line will be guaranteed if MT suction pressure is not lower the set threshold. Note: in the event of pLAN network faults, DSS is disabled. 47 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG 6.6.7 COMMON varying cooling capacity Pre-positioning/start control: if switching from standby to control, before actual control starts the valve is moved to a specific initial position. The prepositioning time is the time in which the valve is kept in a fixed position, according to the parameter “Valve opening at start-up”. Electronic valve synchronisation (EVS) For configuration of the DRIVER or DRIVERS, where there are two heat exchangers, access OTHER FUNCTIONS®EVS; iwhich comprises the following submenus: a. Temperature control b. Manual management c. I/O status d. Control e. Valve configuration f. Driver configuration Temp. control: Manual management: I/O status: Control: Valve configuration: Driver configuration: Parameter/Description CONTROL Pre-positioning time Valve opening at start-up (evaporator /valve capacity ratio) Def. Min. Max. UOM 6 50 0 0 18000 100 s % Tab. 6.g Information relating superheat is shown The valve can be moved to a certain number of steps Display and configuration of the probes connected to the 4 analogue inputs on the driver Valve opening, PID parameters, alarm limits/delays Minimum/maximum number of steps, nominal frequencies Enable driver, defaults The valve opening parameter should be set based on the ratio between rated evaporator and valve cooling capacity (e.g. rated evaporator cooling capacity: 3 kW, rated valve cooling capacity: 10 kW, valve opening = 3/10 = 33%). • If 100% capacity is required: Opening (%)= (Valve opening at start-up); • If capacity required is less than 100% (capacity control): Opening (%)= (Valve opening at start-up) • (Current unit cooling capacity), where the current unit cooling capacity is sent to the driver via pLAN by the pCO controller. For stand-alone drivers this is always equal to 100%. For branches a, b, c, d, e, f refer directly to the parameter table in chapter 7, while for a more detailed explanation of the DRIVER EVD EVO functions, see the technical manual: +0300005EN Note: one DRIVER is needed for each valve; if a Twin Driver is used, this will be managed as a single driver; also the connection must be made on the first valve (EXV1-J27 in the case of built-in drivers). Note: • this procedure is used to anticipate valve movement and bring it much closer to working position immediately after the unit is powered on; • if there are problems with liquid return after the start of the refrigeration Enable driver: The driver can be enabled in the configuration menu (E.i.f ) and once enabled, the number of valves and corresponding addresses of the two drivers can be entered. unit, or there are frequent unit on-off cycles, valve opening at start-up must be decreased. If there are low pressure problems after starting the refrigeration unit, the valve opening must be increased. Positioning (change cooling capacity) In practice, the valve is re-positioned starting from the current position in proportion to how much the unit cooling capacity has increased or decreased, in percentage terms. On reaching the calculated position, irrespective of how long it takes (variable according to the type of valve and the actual position), there will be a constant 5 second delay, after which control resumes. Note: if it is not possible to have the information on the change in unit cooling capacity, this will be always be considered as operating at 100% and therefore the procedure will never be used. In this case, the PID control needs to be more reactive (see Control), so as to respond promptly to variations in load that are not communicated to the driver. Note: • make sure that Fieldbus driver management reflects the logic of the generic functions, i.e. up to 2 drivers per suction line can be enabled, with a limit of 2 drivers per board in the pLAN (L1&L2 on single board, maximum 2 drivers); • on the supervisor, L1, L2 management on separate boards requires the use of two single line templates; • a Fieldbus driver cannot be connected to boards 3 and 4 in pLAN. ON A OFF Screen Eif02 contains the commands to set the defaults for the Driver, after which the parameters are updated (pRack®Driver), ); in addition, the line of compressors used for the pre-positioning logic can be selected t ON C OFF t ON NP OFF t ON R OFF t T3 Note: • Control based on line 1 is only possible on pLAN board with address 1. Fig. 6.ar While control based on the compressors on line 2 is only possible on boards where the low temperature compressors are configured (pLAN 1 for double suction on single board and pLAN2 for double suction on separate boards); • important, if the line is not managed o the current board, the Driver function is disabled. pRack +0300025EN rel. 1.5 - 17.02.2020 W Legenda: A C NP R 48 Control request Change in capacity Re-positioning Control T3 W t Re-positioning time Wait Time ENG 6.6.8 Unit of measure pRack pR300 can manage two units of measure, the international system and Imperial. Regulation request Max Note: the temperature and pressure units of measure can be changed from °C, barg to °F, psig only during start-up; mixed configurations are not allowed, for example °F and barg. offset digital input Min 6.6.9 Sign of life pRack pR300 can manage a digital output acting as a sign of life, activated when pRack pR300 is powered up. This output remains active while the controller is working correctly and highlights any hardware faults. The Signal can be configured in main menu branch B.a.c. time Fig. 6.am • By suitably setting this parameter based on system configuration, one compressor can be shut down; for example if there are three compressors, by setting the decrease to 33%, activation of the input stops one of the three compressors. Compressor shutdown and restart respect the safety times. 6.6.10 Liquid non-return pRack pR300 can manage a digital output with the meaning of liquid nonreturn. This normally active output is deactivated when all the compressors are off and no compressor can be started due to alarms or time settings, despite the control request, or when the unit is OFF. As soon as at least one compressor is enabled to start, the output is deactivated, allowing management of a liquid non-return valve. The function can be configured in main menu branch C.a.g/C.b.g. The digital inputs configured are common to both lines, while for each line a different action can be associated with the same digital input. In any case, the previous actions do not interfere with the pRack pR300 safety features, which always have priority over the actions set from digital input. pRack pR300 can interact with the pLoads controller, which manages power using a load cut-off function. Moreover, a suction pressure safety threshold has been introduced, therefore the actions associated with the inputs are only enabled if the pressure does not exceed this threshold (settable by parameter). After the pLoads action has been disabled, it is necessary that the suction pressure returns below the safety threshold for a setted time (higher than 30 s), before restoring the interaction between the two devices, so to the regulation can be stabilize. Interaction can be enabled and the related parameters set from main menu branch C.a.d and C.b.d. 6.6.12 Power consumption 6.6.11 Interaction with pLoads pRack pR300 can calculate power consumption for the current day and the previous day. The calculation can be enabled and the related parameters set from main menu branch C.a.d and C.b.d. To calculate power consumption, the current draw is measured via an analogue input, while the type of load, rated voltage and displacement can be set by parameter. The calculation starts at 00:00 every day and continues until 24:00, when the value from the previous day is overwritten with the new calculated value. The supervisory system can use the two values, current day’s consumption and previous day’s consumption, for power consumption analysis. Interaction between pRack pR300 and pLoads uses digital inputs or the supervisor. The digital inputs have higher priority, therefore if a digital input is not active, the corresponding action is not produced even if requested by the supervisor. Two of the free digital inputs on pRack pR300 can be configured for connection to two pLoads outputs, with each input being assigned one of the following actions: • No action. Activation of the digital input has no influence on control. • Capacity limited to the current value. Activation of the digital input limits the maximum control request; capacity can be reduced from this value by the controller, but cannot exceed the current value at the moment the digital input was activated for the entire time it remains active, as shown in the figure: 6.7 Settings 6.7.1 Regulation request Clock pRack pR300 features an internal clock with backup battery that keeps the time and date for all related functions (see Chapter 2 for details relating to the hardware). Limit The date on pRack pR300 can be set as follows: • day, month, year (dd/mm/yy) • month, day, year (mm/dd/yy) • year, month, day (yy/mm/dd) The current date and time can be set, the day of the week corresponding to set date displayed, plus changeover to daylight saving can be enabled by setting the changeover date and the deviation. Digital input time The related parameters can be set during start-up or in main menu branch F.a. Fig. 6.al • Capacity limited to a % value, settable by parameter. As in the previous case, the control request is limited at the top end, however to a fixed value set by parameter. • Decrease capacity by a % value, settable by parameter. Activation of the digital input reduces the control request by a fixed value set by parameter, as shown in the figure: Note: the date and time are managed on pRack boards with addresses 1 and 2; on power-up and whenever the pLAN network is reconnected, the software on pRack synchronises the settings on board 2, sending the date and time set on board 1. If the clock card is not operating, an alarm is generated and the functions relating to the time bands described in the following paragraph are not available. 49 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG 6.7.2 Time bands 6.8.2 pRack pR300 allows the operating seasons, the closing periods and weekends to only be set once, and consequently these are common to all the system functions. The values pre-set by Carel can be installed at any time, restoring the pRack pR300 default settings, and requiring the startup procedure described in Chapter 4 to be repeated. As well as these settings, each function can be associated with a weekly scheduler, setting up to 4 different daily activation bands for each day of the week. For each time band, the start and end time can be set and settings made can be copied to the others days of the week. Important: the Carel default reset procedure totally deletes the pRack pR300 permanent memory, and consequently is an irreversible operation; nonetheless, the user settings can still be restored if these have already been saved. Given that pRack pR300, following the installation of the Carel default values requires the startup procedure to be repeated, select the first pre-configuration and then restore the user defaults. The priority of the schedulers, from lowest to highest, is: • weekly scheduler • closing periods • special days Note: to complete a new configuration procedure as described in Chapter 4, first restore the Carel default values. For example, if the weekly scheduler requires activation of a function, yet a closing period is in progress, and requires deactivation of the same function, then the function is deactivated. The following functions allow the setting of time bands: • Split-condenser: the function is active only based on the operating seasons, and consequently special days, closing periods and daily time bands are ignored. • Silencer: the function is only active with daily time bands, there is no link to operating seasons, special days and closing periods • Heat recovery: the function is active with daily time bands, special days and closing periods, no link to operating seasons. The link to the general scheduler can be disabled, considering the time bands only. • Set point compensation: active with operating seasons, special days, closing periods and daily time bands (two different offsets). • Generic functions: the generic scheduling function is active with the operating seasons, special days, closing periods and daily time bands. Operation of the generic functions can be separated from the generic scheduler, considering the daily time bands only. For details on the functions that use time bands, see the corresponding paragraphs. 6.8 Managing the default values pRack pR300 can manage two different sets of default values: • user defaults • Carel defaults The two functions can be activated in main menu branch I.d. Important: after having reset the default values, the pRack pR300 board need to be switched off and on again. 6.8.1 Saving and resetting the user default values pRack pR300 can save the exact configuration set by the user inside the instrument, allowing it to be recalled at any time. All the set values are saved, therefore loading user defaults restores the exact same conditions that the pRack pR300 controller was in when the data were saved. Note: only one user default configuration can be saved, therefore when the data is next saved, this overwrites the previous data. Important: • the Carel default reset procedure totally deletes the pRack pR300 permanent memory, and consequently is an irreversible operation; • the user values cannot be reset after updating the software on the pRack pR300, nonetheless see Chapter 10 for details on how to save the parameters for versions different of the software. pRack +0300025EN rel. 1.5 - 17.02.2020 Resetting the Carel default values The Carel default values are shown in the Parameters table in Chapter 7. 50 ENG 7. PARAMETERS TABLE Below is the table of the parameters that can be displayed on the terminal. The values indicated with ‘---‘ are not Significant or are not set, while the values indicated with ‘…’ may vary according to the configuration, with the possible options visible on the user terminal. A row of ‘…’ means that there are a series of parameters Similar to the previous ones. Legenda: “Mask index”: indicates the unique address of each screen and consequently the path needed to reach the parameters available on this screen; for example, to reach the parameters corresponding to the suction pressure probe with mask index Bab01, proceed as follows: Main menù Mask index Main screen Main screen (display only) Secondary screen (display only) Note: Not all the screens and parameters shown in the table are always visible or can be set, the screens and parameters that are visible or can be set depend on the configuration and the access level. B.In./Out.èa.Statusèb.Analog.in. Description on terminal Description Default UOM Values ----L1-Suction L1-Condenser L1-SHeat L1-Suct. temp. L1-Dis. temp. L1-Auxiliary L2-Suction L2-Condenser L2-SHeat L2-Suct. temp. L2-Dis. temp. L2-Auxiliary EVD1-Condenser EVD2-Condenser --- Hours and minutes Date Suction pressure or temperature (configurable, line 1) Condensing pressure or temperature (configurable, line 1) Superheat (configurable, line 1) Suction temperature (configurable, line 1) Discharge temperature (configurable, line 1) Auxiliary pressure or temperature (configurable, line 1) Suction pressure or temperature (configurable, line 2) Condensing pressure or temperature (configurable, line 2) Superheat (configurable, line 2) Suction temperature (configurable, line 2) Discharge temperature (configurable, line 1) Auxiliary pressure or temperature (configurable, line 2) Condensing pressure or temperature (configurable on Driver 1, line 2) Condensing pressure or temperature (configurable on Driver 2, line 2) Unit status (with unit OFF) … … ------------------------------- … … … … … … … … … … … … … … … … --- ------------------L1-Suction L1-Condenser L1-SHeat L1-Suct. temp. L1-Dis. temp. L1-Auxiliary L2-Suction L2-Condenser L2-SHeat L2-Suct. temp. L2-Dis. temp. L2-Auxiliary EVD1-Condenser EVD2-Condenser --- Number of compressors on line 1(with unit ON, configurable) Compressor activation percentage on line 1 (with unit ON, configurable) Number of compressors on line 2(with unit ON, configurable) Compressor activation percentage on line 2 (with unit ON, configurable) Number of fans on line 1 (with unit ON, configurable) Fan activation percentage on line 1 (with unit ON, configurable) Number of fans on line 2 (with unit ON, configurable) Fan activation percentage on line 2 (with unit ON, configurable) Hours and minutes Date Suction pressure or temperature (configurable, line 1) Condensing pressure or temperature (configurable, line 1) Superheat (configurable, line 1) Suction temperature (configurable, line 1) Discharge temperature (configurable, line 1) Auxiliary pressure or temperature (configurable, line 1) Suction pressure or temperature (configurable, line 2) Condensing pressure or temperature (configurable, line 2) Superheat (configurable, line 2) Suction temperature (configurable, line 2) Discharge temperature (configurable, line 1) Auxiliary pressure or temperature (configurable, line 2) Condensing pressure or temperature (configurable on Driver 1, line 2) Condensing pressure or temperature (configurable on Driver 2, line 2) Unit status (with unit OFF) ----------------… … ------------------------------- --% --% --% --% … … … … … … … … … … … … … … … … --- ----------------- Number of compressors on line 1(with unit ON, configurable) Compressor activation percentage on line 1 (with unit ON, configurable) Number of compressors on line 2(with unit ON, configurable) Compressor activation percentage on line 2 (with unit ON, configurable) Number of fans on line 1 (with unit ON, configurable) Fan activation percentage on line 1 (with unit ON, configurable) Number of fans on line 2 (with unit ON, configurable) Fan activation percentage on line 2 (with unit ON, configurable) ----------------- --% --% --% --% … … …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) Unit OFF from Alarm Unit OFF from blackout Unit OFF from supervisor Unit OFF from default Unit OFF from digital IN Unit OFF from keypad Unit OFF manual mode 0…12 0…100 0…12 0…100 0…16 0…100 0…16 0…100 … … …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) …(**) Unit OFF from Alarm Unit OFF from blackout Unit OFF from supervisor Unit OFF from default Unit OFF from digital IN Unit OFF from keypad Unit OFF manual mode 0…12 0…100 0…12 0…100 0…16 0…100 0…16 0…100 51 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Mask index Display description Description Default UOM Values Suction pressure (line 1) Saturated suction temperature (line 1) Effective set point for pressure control (with compensation applied, line 1) Control differential for pressure control (line 1) Suction pressure (line 1) Saturated suction temperature (line 1) Effective set point for temperature control (with compensation applied, line 1) Control differential for temperature control (line 1) Capacity delivered/capacity required for suction line (line 1) Control status (according to the type of control set, line 1) ----… (**) … (**) ----… (**) … (**) ----- … … … … … … … … % ----… s % … % … … … … … … … 0…100 … (**) … (**) … (**) … … (**) 0…29 ON / OFF … … … 0…29 ON / OFF Discharge temperature Cap.reduction Oil sump temp. Oil status Neutral zone Effective suction pressure set point (with compensation applied, line 1) … (**) Time remaining to next compressor start (line 1) --Capacity delivered by compressor 1 on line 1 (a ''!'' to the right of the value means --that some form of compressor capacity override is active, e.g. times, alarms, start-up procedure) … … Capacity delivered by compressor 12 (line 1) --Suction temperature (line 1) --Superheat (line 1) --Discharge temperature, compressor 1 (line 1) --… … Discharge temperature, compressor 6 (line 1) --Number of digital output associated and status of liquid injection/ --economizer (*) compressor 1 (line 1) … … Number of digital output associated and status of liquid injection/ --economizer (*) compressor 6 (line 1) Digital ScrollTM compressor discharge temperature (line 1) --Digital ScrollTM compressor capacity reduction in progress (line 1) Digital ScrollTM compressor oil sump temperature (line 1) --Digital ScrollTM compressor oil dilution status (line 1) … (**) … (**) … (**) … (**) … (**) … (**) … (**) … (**) 0/0 …100/100 Stop Increas Operating Decrease Timings Standby Alarms Proportional band Neutral zone … (**) 0…32000 0…100 … Status Digital ScrollTM compressor operating status (line 1) --- --- Countdown Compr. Digital ScrollTM compressor time count (line 1) Digital ScrollTM compressor status (line 1) ----- s --- Valve Digital ScrollTM valve status(line 1) --- --- Requested cap. Current capac. Pressure Sat.temp. Act.setpoint Differential Pressure Sat.temp. Act.setpoint Differential Actual/req. Status Digital ScrollTM compressor capacity required (line 1) Digital ScrollTM compressor effective capacity (line 1) Condensing pressure (line 1) Saturated condensing temperature (line 1) Effective set point for pressure control (with compensation applied, line 1) Control differential for pressure control (line 1) Condensing pressure (line 1) Saturated condensing temperature (line 1) Effective set point for temperature control (with compensation applied, line 1) Control differential for temperature control (line 1) Capacity delivered/capacity required for condenser line (line 1) Control status (according to the type of control set, line 1) --------… (**) … (**) ----… (**) … (**) ----- % % … … … … … … … … % --- Reg.type Condenser control type (line 1) --- Setpoint F1 … % … --- … % … 0…100 --- % 0…100 … --- … % … 0…100 Discharge temperature External temperature Pressure Sat.temp. Act.setpoint Differential Pressure Sat.temp. Act.setpoint Differential Actual/req. Status Condenser control effective set point (with compensation applied, line 1) Power output of fan 1 on line 1 (a ''!'' to the right of the value means that some form of power override is active) … Power output of fan 8 on line 1 (a ''!'' to the right of the value means that some form of power override is active) Power output of fan 9 on line 1 (a ''!'' to the right of the value means that some form of power override is active) … Power output of fan 16 on line 1 (a ''!'' to the right of the value means that some form of power override is active) Discharge temperature (line 1) Outside temperature (line 1) Suction pressure (line 2) Saturated suction temperature (line 2) Effective set point for pressure control (with compensation applied, line 2) Control differential for pressure control (line 2) Suction pressure (line 2) Saturated suction temperature (line 2) Effective set point for temperature control (with compensation applied, line 2) Control differential for temperature control (line 2) Capacity delivered/capacity required for suction line (line 2) Control status (according to the type of control set, line 2) Neutral zone … (**) --- … (**) NO / YES … (**) Ok Dilute Off Off by time Start up On by time On Mod. manual Alarm In pump down 0…999 OFF ON OFF ON 0…100 0…100 … (**) … (**) … (**) … (**) … (**) … (**) … (**) … (**) 0/0 …100/100 Stop Operating Increase Timings Decrease Alarms Stand-by Proportional band Neutral zone … (**) 0…100 --------… (**) … (**) ----… (**) … (**) ----- … … … … … … … … … … % --- Reg.type Compressor control type (line 2) --- Setpoint Effective suction pressure set point (with compensation applied, line 2) Neutral zone … (**) … (**) … (**) … (**) … (**) … (**) … (**) … (**) … (**) … (**) … (**) 0/0 …100/100 Stop Operating Increase Timings Decrease Alarms Stand-by Proportional band Neutral zone … (**) A.Unit status Pressure Aa01 Sat.temp. (display only) Act.setpoint Differential Pressure Aa02 Sat.temp. Act.setpoint (display only) Differential Actual/req. Aa03 (display only) Reg.status Reg.type Setpoint C01, C02, …C12 C01 Aa04 (display only) Aa05 (display only) Aa11 (display only) Aa13 (display only) Aa15 (display only) Aa16 (display only) Aa20 (display only) Aa21 (display only) … C12 Temperature Superheat Disch.1 … Disch.6 Liq.inj.1: DO … Liq.inj.6: DO Compressor control type (line 1) … Aa22 (display only) Aa23 (display only) … F8 F9 Aa24 (display only) Aa25 (display only) Aa31 (display only) Aa32 (display only) … F16 Aa33 (display only) pRack +0300025EN rel. 1.5 - 17.02.2020 52 … ENG Mask index Display description C01, C02, …C12 C01 … C12 Temperature Superheat Disch.1 … Disch.6 Liq.inj.1: DO … Liq.inj.6: DO Discharge temperature Cap.reduction Oil sump temp. Oil status Description Time remaining to next compressor start (line 2) Capacity delivered by compressor 1 on line 2 (a ''!'' to the right of the value means that some form of compressor capacity override is active, e.g. times, alarms, start-up procedure) … Capacity delivered by compressor 12 (line 2) Suction temperature (line 2) Superheat (line 2) Discharge temperature, compressor 1 (line 2) … Discharge temperature, compressor 6 (line 2) Number of digital output associated and status liquid injection compr. 1 (line 2) … Number of digital output associated and status liquid injection compr. 6 (line 2) Digital ScrollTM compressor discharge temperature (line 2) Digital ScrollTM compressor capacity reduction in progress (line 2) Digital ScrollTM compressor oil sump temperature (line 2) Digital ScrollTM compressor oil dilution status (line 2) Status Digital ScrollTM compressor operating status (line 2) --- --- Countdown Compr. Valve Requested cap. Current capac. Pressure Sat.temp. Act.setpoint Differential Pressure Sat.temp. Act.setpoint Differential Actual/req. Reg.status Digital ScrollTM compressor time count (line 2) Digital ScrollTM compressor status (line 2) Digital ScrollTM valve status(line 2) Digital ScrollTM compressor capacity required (line 2) Digital ScrollTM compressor effective capacity (line 2) Condensing pressure (line 2) Saturated condensing temperature (line 2) Effective set point for pressure control (with compensation applied, line 2) Control differential for pressure control (line 2) Condensing pressure (line 2) Saturated condensing temperature (line 2) Effective set point for temperature control (with compensation applied, line 2) Control differential for temperature control (line 2) Capacity delivered/capacity required for condenser line (line 2) Control status (according to the type of control set, line 2) --------------… (**) … (**) ----… (**) … (**) ----- s ----% % … … … … … … … … % --- Reg.type Condenser control type (line 2) --- Setpoint F1 … % … --- … % … 0…100 --- % 0…100 … --- … % … 0…100 Discharge temperature External temperature Status,curr. Condenser control effective set point (with compensation applied, line 2) Power output of fan 1 on line 2 (a ''!'' to the right of the value means that some form of power override is active) … Power output of fan 8 on line 2 (a ''!'' to the right of the value means that some form of power override is active) Power output of fan 9 on line 2 (a ''!'' to the right of the value means that some form of power override is active) … Power output of fan 16 on line 2 (a ''!'' to the right of the value means that some form of power override is active) Discharge temperature (line 2) Outside temperature (line 2) Effective status of screw compressor 1 with stepped modulation Neutral zone … (**) --- … 0…100 … (**) … (**) … (**) … … (**) 0…29 ON / OFF … 0…29 ON / OFF … (**) NO / YES … (**) Ok Dilute Off Off by time Start up On by time On Manual mod. Alarm In pump down 0…999 OFF / ON OFF / ON 0…100 0…100 … (**) … (**) … (**) … (**) … (**) … (**) … (**) … (**) 0/0 …100/100 Stop Operating Increase Timings Decrease Alarms Stand-by Proportional band Neutral zone … (**) 0…100 ------- … … --- Status, req. Status required for the screw compressor 1 with stepped modulation --- --- Minimum on time Min.off/starts Countdown for minimum on time screw comp. 1 with stepped modulation Countdown for minimum off time or wait between successive starts screw comp. 1 with stepped modulation Countdown for next step activation screw comp. 1 with stepped modulation Effective status of screw compressor 1 with continuous capacity modulation ----- s s … (**) … (**) Off Start up Stage1 Off Start up Stage1 0…999 0…999 ----- s --- ----- s s Min.on countdown Status,curr. Screw comp. 1 off time with continuous capacity modulation Countdown for minimum off time or wait between successive starts screw comp. 1 with continuous capacity modulation Countdown to start screw comp. 1 with continuous capacity modulation Effective status of screw compressor 2 ----- s --- Status, req. Status required for the screw compressor 2 --- --- Minimum on time Min.off/starts Next step Zone Max admit.time Countdown Max admit.power Startup status Countdown for minimum on time screw comp. 2 Countdown for minim. off time or wait between successive starts screw comp. 2 Countdown for next step activation screw comp. 2 Envelope zone for screw compressor 1 Maximum duration allowed in the zone Countdown Maximum capacity allowed in the zone Start-up status for screw compressor 1 --------- --- s s s --min s % --- N° startup restart Number of restarts --- --- Aa34 (display only) Aa05 (display only) Aa41 (display only) Aa43 (display only) Aa45 (display only) Aa46 (display only) Aa50 (display only) Aa51 (display only) Default ----- UOM s % Values 0…32000 0…100 … --------… ----… ----- … % … … … … … … … … … --- … Aa52 (display only) Aa53 (display only) … F8 F9 Aa54 (display only) Aa55 (display only) … F16 Aa60 (display only) Next step Status Aa61 (display only) Aa62 (display only) Aa70 (display only) Shut down countd. Max.pow.countdown Aa71 (display only) 53 0… 999 Off Start up Norm. operating 0…999 0…999 Stage 2 Stage 3 Stage 4 Stage 2 Stage 3 Stage 4 Shut down 0…999 Off Stage 2 Start up Stage 3 Stage1 Stage 4 Off Stage 2 Start up Stage 3 Stage1 Stage 4 0…999 0…999 0…999 0…14 0…999 0…32000 0…100 Off Compressor on Intermediate interval Final interval Compressor off Restart Alarm 0…99 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Mask index Display description Err.code Al.code Description Type of error in envelope definition Type of alarm activated Default ----- UOM ----- Envel.def.error code Type of error in selection of predefined envelope --- --- Reg.var. Enable Control variable value for generic stage function 1 Enabling variable status for generic stage function 1 ----- … --- Setpoint Differential Mode Status … Reg.var. Enable Setpoint Differential Mode Status Reg.variable Enable Setpoint Differential Mode Status Reg.variable Enable Setpoint Differential Mode Status Reg.variable Enable Type Delay time Status Reg.variable Enable Type Delay time Status Weekday TB1: --:-- -> --:-- Control set point for generic stage function 1 --Control differential for generic stage function 1 --Control mode for generic stage function 1 (direct or reverse) --Status of generic stage function 1 --… … Control variable value for the generic stage function 5 --Enabling variable status for the generic stage function 5 --Control set point for the generic stage function 5 --Control differential for the generic stage function 5 --Control mode for the generic stage function 5 (direct or reverse) --Status of generic stage function 5 --Control variable value for generic modulating function 1 --Enabling variable status for generic modulating function 1 --Control set point for generic modulating function 1 --Control differential for generic modulating function 1 --Control mode for generic modulating function 1 (direct or reverse) --Status of generic modulating function 1 --Control variable value for generic modulating function 2 --Enabling variable status for generic modulating function 2 --Control set point for generic modulating function 2 --Control differential for generic modulating function 2 --Control mode for generic modulating function 2 (direct or reverse) --Status of generic modulating function 2 --Control variable status for generic alarm function 1 --Enabling variable status for generic alarm function 1 --Type of alarm for generic alarm function 1 --Control differential for generic alarm function 1 --Status of generic alarm function 1 --Control variable status for generic alarm function 2 --Enabling variable status for generic alarm function 2 --Type of alarm for generic alarm function 2 --Control differential for generic alarm function 2 --Status of generic alarm function 2 --Day of the week --Enabling and definition of time band 1: start hour and minutes, end hour and --minutes for the generic scheduling function … … Enabling and definition of time band 4: start hour and minutes, end hour and --minutes for the generic scheduling function Status of generic scheduling function --Status of heat recovery function (line 1) --Heat recovery temperature (line 1) --Status of modulating heat recovery valve output (line 1) --Status of prevention via heat recovery (line 1) --Status of heat recovery function (line 2) --Heat recovery temperature (line 2) --Status of modulating heat recovery valve output (line 2) --Status of prevention via heat recovery (line 2) --Status of ChillBooster device (line 1) --Outside temperature (line 1) --ChillBooster activation threshold (line 1) --Number of minutes elapsed with fans at 100/number of min. allowed (line 1) --Status of ChillBooster device (line 2) --Outside temperature (line 2) --ChillBooster activation threshold (line 2) --Number of minutes elapsed with fans at 100/number of minutes allowed (line 1) --Saturated condensing temperature (line 1) --Liquid temperature (line 1) --Subcooling (line 1) --Status of subcooling function (line 1) --Description and status of the reduced power consumption action associated with --the first digital input from pLoads (line 1) Description and status of the reduced power consumption action associated with --the second digital input from pLoads (line 1) Description and status of the reduced power consumption action associated with --the first digital input from pLoads (line 2) Description and status of the reduced power consumption action associated with --the second digital input from pLoads (line 2) Value read by the current sensor (line 1) --Instant power calculated (line 1) --Power consumption during the current day (line 1) --Power consumption during the previous day (line 1) --User-defined set point for suction pressure control, proportional control --(line 1) Effective set point for suction pressure control, proportional control (with compen- --sation applied, line 1) Suction pressure control differential, proportional control (line 1) --- … … ----… … --… … ----… --… … --% … --… … --% ------s --------s ----… Values No error / Env. def. inconsist.. No Alarm Max time elapsed Zone not allowed Max. no. of restarts No error Comp. not supported Gas type not allowed … (**) Not active active … (**) … (**) D, R Not active / Active … … (**) Not active / Active … (**) … (**) D, R Not active / Active … (**) Not active / Active … (**) … (**) D, R 0.0…100.0 … (**) Not active / Active … (**) … (**) D, R 0.0…100.0 Not active / Active Not active / Active Light / Serious 0…9999 Not active / Active Not active / Active Not active / Active Light / Serious 0…9999 Not active / Active Monday, …, Sunday … … … … … ----… ------… ------… … min --… … min … … … --- Not active / Active OFF / ON … (**) 0.0…100.0 OFF / ON OFF / ON … (**) 0.0…100.0 OFF / ON OFF / ON … (**) … (**) 0…999/0…999 OFF / ON … (**) … (**) 0…999/0…999 … (**) … (**) … (**) Open / Closed --- OFF / ON --- OFF / ON --- OFF / ON Aa72 (display only) Aaan (display only) … Aaar (display only) Aaas (display only) Aaat (display only) Aaau (display only) Aaav (display only) Aaaw (display only) Aaax (display only) Aaay (display only) Aaaz (display only) Aaa1 (display only) Aaa2 (display only) Aaa4 (display only) Aaa5 (display only) Aaa6 (display only) Ab01 (display only) … TB4: --:-- -> --:-Status Status Heat recl. temp. An.OUT modulat. HR Prevent Status Heat recl. temp. An.OUT modulat. HR Prevent Status Ext.temp. Ext.temp.thr. Time fan 100% Status Ext.temp. Ext.temp.thr. Time fan 100% Cond.temp. Liquid Temp. Subcooling Status Action 1 Action 2 Action 1 Action 2 Current Inst. power Power today Previous User setp. Actual.setpoint Diff. pRack +0300025EN rel. 1.5 - 17.02.2020 54 --- OFF / ON A kW kWh kWh … 0 to 999.9 0 to 100 0 to 32767 0 to 32767 … (**) … … (**) … … (**) ENG Mask index Display description User setp. Actual.setpoint Ab02 (display only) Neutral zone Incr.diff. Decr.diff. User setp. Ab03 (display only) Actual.setp. Diff. User setp. Ab04 (display only) Ab05 (display only) Actual.setp. Neutral zone Incr.diff. Decr.diff. User setp. Actual.setp. Diff. User setp. Actual.setp. Ab06 (display only) Neutral zone Incr.diff. Decr.diff. User setp. Ab07 (display only) Actual.setp. Diff. User setp. Actual setp. Ab08 (display only) Neutral zone Incr.diff. Decr.diff. Ab12 Ab13 Ab14 Ab15 Setpoint Setpoint Setpoint Setpoint Status Description Default User-defined set point for suction pressure control, proportional control --(line 1) Effective set point for suction pressure control, proportional control (with compen- --sation applied, line 1) Neutral zone for suction pressure control (line 1) --Increase differential for suction pressure control, neutral zone control (line 1) --Decrease differential for suction pressure control, neutral zone control --(line 1) User-defined set point for suction pressure control, proportional control --(line 2) Effective set point for suction pressure control, proportional control (with compen- --sation applied, line 2) Suction pressure control differential, proportional control (line 2) --User-defined set point for suction pressure control, proportional control --(line 2) Effective set point for suction pressure control, proportional control (with compen- --sation applied, line 2) Neutral zone for suction pressure control (line 2) --Increase differential for suction pressure control, neutral zone control (line 2) --Decrease differential for suction pressure control, neutral zone control (line 2) --User-defined set point for condensing pressure control, proportional control (line --1) Effective set point for condensing pressure control, proportional control (with --compensation applied, line 1) Condensing pressure control differential, proportional control (line 1) --User-defined set point for condensing pressure control, proportional control (line --1) Effective set point for condensing pressure control, proportional control (with --compensation applied, line 1) Neutral zone for condensing pressure control (line 1) --Increase differential for the condensing pressure control, neutral zone control (line --1) Decrease differential for the condensing pressure control, neutral zone control --(line 1) User-defined set point for condensing pressure control, proportional control (line --2) Effective set point for condensing pressure control, proportional control (with --compensation applied, line 2) Condensing pressure control differential, proportional control --(line 2) User-defined set point for condensing pressure control, proportional control (line --2) Effective set point for condensing pressure control, proportional control (with --compensation applied, line 2) Neutral zone for condensing pressure control (line 2) --Increase differential for the condensing pressure control, neutral zone control (line --2) Decrease differential for the condensing pressure control, neutral zone control --(line 2) Setpoint without compensation (suction line 1) 3,5 barg Setpoint without compensation (condenser line 1) 12,0 barg Setpoint without compensation (suction line 2) 3,5 barg Setpoint without compensation (condenser line 2) 12,0 barg Unit status (display only) Off from keypad UOM … Values … (**) … … (**) … … … … (**) … (**) … (**) … … (**) … … (**) … … … (**) … (**) … … (**) … … … … … (**) … (**) … (**) … (**) … … (**) … … … (**) … (**) … … (**) … … … (**) … (**) … … (**) … … (**) … … (**) … … (**) … … (**) … … (**) … … … (**) … (**) … … (**) … … … … --- … (**) … (**) … (**) … (**) Waiting.. Off by default Unit On/ Off by DIN Off from alarm Off from keypad Off from blackout Manual op. Off from BMS Prevent HP Ac01 Ac02 Ac03 Ac04 Ac06 Ac07 --L1: L2: ----Enable of unit OnOff By digit input By supervisor By black out Unit on delay after blackout Enable of unit OnOff By digit input By supervisor By black out Unit on delay after blackout On-Off from keypad (line 1) Unit status (display only) ----- OFF / ON …(See above Ac01) On-Off from keypad (line 1) On-Off from keypad (line 2) Enable unit On/Off from digit input (line 1) OFF Off from keypad OFF OFF NO ------- OFF / ON OFF / ON NO / YES Enable unit On/Off from supervisor (line 1) Enable unit On/Off from black out (line 1) System on delay after black out (line 1) NO NO 0 ----s NO / YES NO / YES 0…999 Enable unit On/Off from digit input (line 2) NO --- NO / YES Enable unit On/Off from supervisor (line 2) Enable unit On/Off from black out (line 2) System on delay after black out (line 2) NO NO 0 ----s NO / YES NO / YES 0…999 55 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Mask index Display Description Description Default UOM Values B.Input./output (the I/Os available depend on the selected configuration, the following are just some examples. For the complete list of I/O positions available see Appendix A.5) DI Alarm 1 for compressor 1 DI position (line 1) 03 -----, 01…18, B1…B10 (****) Status (display only) Status of alarm 1 for compressor 1 DI (line 1) ----Closed Baa02 Open Logic Logic of alarm 1 for compressor 1 DI (line 1) NC --NC / NO Function (display only) Alarm 1 for compressor 1 function status (line 1) ----Not active / Active … … … … … … --Suction pressure probe position (line1) B1 -----, B1…B10 (****) --Suct pressure probe type (line 1) 4-20mA -----0-1V - 0-10V- 4-20mA- 0-5V Bab01 --- (display only) Suction pressure value (line 1) --… … (**) Upper value Suct pressure maximum value (line 1) 7,0 barg … … (**) Lower value Suct pressure minimum value (line 1) -0,5 barg … … (**) Calibration Suction pressure probe adjustment (line 1) 0.0 barg … … (**) … … … … … … Line relay DO Compressor 1 line DO position and status (On/Off ) display (line 1) … -----, 01…29 (****) Part winding DO/Star relay Compressor 1 part winding or star DO position and status (On/Off ) display … -----, 01…29 (****) Bac02 DO (*) (line 1) ---/ Delta relay DO (*) Compressor 1 delta DO position and status (On/Off ) display (line 1) … -----, 01…29 (****) Logic DO logic to start compressor 1 (line 1) NC --NC / NO DO Compressor 1 unloader 1 DO position (line 1) … -----, 01…29 (****) Status (display only) Status for compressor 1 unloader 1 DO (line 1) ----Closed / Open Bac03 Logic Logic for compressor 1 unloader 1 DO (line 1) NO --NC / NO Function (display only) Compressor 1 unloader 1 function status (line 1) ----Not active / Active … … … … … … AO Compressor modulating device AO position (line 1) 0 -----, 01…06 (****) ---Type of output, PWM / phase control for compressor modulating device (line FCS1*-CONBad01 Type (****) --FCS1*-CONVONOFF 1) VONOFF FCS3*-CONV010" Status (display only) Modulating device output value (line 1) 0 % 0.0 to 100.0 … … … … … … Suction L1 Suction line 1 in manual mode DIS --DIS / EN Suction L2 Suction line 2 in manual mode DIS --DIS / EN Discharge L1 Condenser line 1 in manual mode DIS --DIS / EN Bb01 Discharge L2 Condenser line 2 in manual mode DIS --DIS / EN Timeout Manual mode duration after last key pressed 10 min 0…500 Compressor 1 Manual stages request for compressor 1 (line 1) OFF --OFF / ON 3 STAGES (*) Bba02 Force to 2 STAGES (*) 4 STAGES (*) … … … … … … Compressor 12 Manual stage request for compressor 12 (line 1) OFF --OFF / ON 3 STAGES (*) Bba16 Force to 2 STAGES (*) 4 STAGES (*) Oil cool pump1 Manual operating status for oil cooling pump 1 (line 1) OFF --OFF / ON Force to Bba17 Oil cool pump2 Manual operating status for oil cooling pump 2 (line 1) OFF --OFF / ON Force to Oil cool fan Manual operating status for oil cooling fan (line 1) OFF --OFF / ON Bba18 Force to Compressor 1 Manual stage request for compressor 1 (line 2) OFF --OFF / ON 3 STAGES (*) Bba20 Force to 2 STAGES (*) 4 STAGES (*) … … … … … Compressor 12 Manual stage request for compressor 12 (line 2) OFF --OFF / ON 3 STAGES (*) Bba34 Force to 2 STAGES (*) 4 STAGES (*) Oil cool pump1 Manual operating status for oil cooling pump 1 (line 2) OFF --OFF / ON Force to Bba35 Oil cool pump2 Manual operating status for oil cooling pump 2 (line 2) OFF --OFF / ON Force to Oil cool fan Manual operating status for oil cooling fan (line 2) OFF --OFF / ON Bba37 Force to Fan1 Manual operating status for fan 1 (line 1) OFF --OFF / ON Bba38 force … … … … … … Fan16 Manual operating status for fan 16 (line 1) OFF --OFF / ON Bba53 force Heat reclaim pump Manual operating status for heat recovery pump (line 1) OFF --OFF / ON Bba54 force ChillBooster Manual operating status for ChillBooster (line 1) OFF --OFF / ON Bba55 force Fan1 Manual operating status for fan 1 (line 2) OFF --OFF / ON Bba57 force … … … … … Fan16 Manual operating status for fan 16 (line 2) OFF --OFF / ON Bba72 force Heat reclaim pump Manual operating status for heat recovery pump (line 2) OFF --OFF / ON Bba73 force ChillBooster Manual operating status for ChillBooster (line 2) OFF --OFF / ON Bba74 force Compressor 1 Manual continuous capacity request for compressor 1 (line 1) 0.0 % 0.0…100.0 Bbb05 Force to Oil cool pump Manual request for oil cooling pump (line 1) 0.0 % 0.0…100.0 Bbb06 Force to Compressor 1 Manual continuous capacity request for compressor 1 (line 2) 0.0 % 0.0…100.0 Bbb07 Force to Oil cool pump Manual request for oil cooling pump (line 2) 0.0 % 0.0…100.0 Bbb08 Force to Fan1 Manual continuous capacity request for fan 1 (line 1) 0.0 % 0.0…100.0 Bbb09 Force to Heat reclaim pump Manual request for heat recovery pump (line 1) 0.0 % 0.0…100.0 Bbb10 force Fan1 Manual continuous capacity request for fan 1 (line 2) 0.0 % 0.0…100.0 Bbb11 Force to Heat reclaim pump Manual request for heat recovery pump (line 2) 0.0 % v Bbb12 force pRack +0300025EN rel. 1.5 - 17.02.2020 56 ENG Mask index Bc01 Bc02 Bca10 … Display Description Test Dout Timeout Test Aout Timeout DO1 … DO29 Bca26 Bcb10 … Bcb12 AO1 AO6 Mask index Display description Description Enable DO test mode Test mode duration after last button pressed Enable AO test mode Test mode duration after last button pressed DO 1 logic for test DO 1 value for test … DO 29 logic for test DO 29 value for test AO 1 value for test … AO 6 value for test Default NO 10 NO 10 NO OFF … NO OFF 0.0 … 0.0 UOM --min --min ----… ------… --- Description Default UOM Values NO / YES 0…500 NO / YES 0…500 NO / NC OFF / ON … NO / NC OFF / ON 0.0…100.0 … 0.0…100.0 Values C.Compressors(*) (The I/Os available depend on the selected configuration, the following are just some examples. For the complete list of I/O positions available see Appendix A.5) Caa01 … Caa08 Caa09 … Caa14 … DI Status (display only) Logic Function (display only) … Line relay DO Alarm 1 for compressor 1 DI position (line 1) Status of alarm 1 for compressor 1 DI (line 1) Logic of alarm 1 for compressor 1 DI (line 1) Alarm 1 for compressor 1 function status (line 1) … Compressor 1 part winding or star DO position and status (On/Off ) display (line 1) Compressor 1 delta DO position and status (On/Off ) display (line 1) 03 --NC --… … … --- ---, 01…29 (****) Compressor 1 line DO position and status (On/Off ) display (line 1) DO logic to start compressor 1 (line 1) Unloader 1 for compressor 1 DO position (line 1) Status of unloader 1 for compressor 1 DI (line 1) Logic of unloader 1 for compressor 1 DI (line 1) Unloader 1 for compressor 1 function status (line 1) … Compressor modulating device AO position (line 1) … NC … --NC --… 0 ------------… --- ---, 01…29 (****) NC / NO ---, 01…29 (****) Closed / Open NC / NO Not active / Active … ---, 01…06 (****) Type (****) Type of output, PWM / phase control for compr. modulating device (line 1) FCS1*-CONVONOFF --- ----, FCS1*-CONVONOFF FCS3*-CONV010" Status (display only) … ----- Modulating device output value (line 1) … Suction pressure probe position (line1) Suct pressure probe type (line 1) 0 … B1 4-20mA % … ----- --- (display only) Upper value Lower value Calibration … Regulation by Regulation type Suction temperature value (line 1) Suct pressure maximum limit (line 1) Suct pressure minimum limit (line 1) Suction pressure probe adjustment (line 1) … Compressor control by temperature or pressure (line 1) Compressor control type (line 1) --7,0 barg -0,5 barg 0.0 barg … PRESSURE NEUTRAL ZONE … (**) … (**) … (**) PROPORT. 300 … (**) … (**) … (**) … (**) NO … (**) 15 … … … … … ----… … … --s … … … … --… s 0.0…100.0 … ---, B1…B10 (****) ---0-1V 0-10V 4-20mA 0-5V … (**) … (**) … (**) … (**) … PRESSURE TEMPERATURE PROPORTIONAL BAND NEUTRAL ZONE … (**) … (**) … (**) PROPORTIONAL PROP.+INT. 0…999 … (**) … (**) … (**) … (**) NO / YES … (**) 0…9999 90 s 0…9999 30 s 0…9999 180 s 0…9999 Part winding DO/Star relay DO (*) ---/ Delta relay DO (*) Logic DO Status (display only) Logic Function (display only) … AO --------… --- Caaal … Cab01 Minimum Maximum Setpoint Reg.type Cab04/Cab6 (**) Integral time Cab05/Cab7 (**) Differential NZ diff. Cab08/Cab10 (**) Activ.diff. Deact.diff. En.force off power Cab09/Cab11 (**) Setp.for force off Power load to 100% min time Cab12 Power load to 100% max time Power unload to 0% min time Cab13 Power unload to 0% max time Enable Aux cont. Probe type Cab02 Cab03 Compressor setpoint lower limit (line 1) Compressor setpoint higher limit (line 1) Compressor setpoint (line 1) Type for proportional control (line 1) Integral time for proportional control (line 1) Differential for proportional control (line 1) Neutral zone control differential (line 1) Neutral zone control differential for device activation (line 1) Neutral zone control differential for device deactivation (line 1) Enable capacity immediate decreasing to 0 (line 1) Threshold for capacity decreasing to 0 (line 1) Minimum time to increase capacity request to 100%, Neutral zone control (suction line 1) Maximum time to increase capacity request to 100%, Neutral zone control (suction line 1) Minimum time to decrease capacity request to 0%, Neutral zone control (suction line 1) Maximum time to decrease capacity request to 0%, Neutral zone control (suction line 1) Enable auxiliary control Probe used for auxiliary control NO PRESSURE Refrig. type Type of refrigerant in auxiliary circuit R404A Working hours Compressor 1 (Check in…) Compressor 2 (Check in…) … Working hours Compressor 11 (Check in…) Compressor 12 (Check in…) Compressor threshold working hours Compressor hours reset Compressor 1 operating hours (line 1) --- h NO/YES PRESSURE/TEMPERATURE R22 - R134a - R404A - R407C -R410A - R507A - R290 - R600 R600a - R717 -R744 - R728 - R1270 - R417A - R422D -R413A - R422A - R423A - R407A - R427A - R245Fa - R407F - R32\ 0…999999 Compressor 1 remaining operating hours (line 1) Compressor 2 operating hours (line 1) Compressor 2 remaining operating hours (line 1) … Compressor 11 operating hours (line 1) … --… … --- h h h … h 0…999999 0…999999 0…999999 … 0…999999 Compressor 11 remaining operating hours (line 1) Compressor 12 operating hours (line 1) Compressor 12 remaining operating hours (line 1) Compressor maintenance threshold hours (line 1) … --… 88000 h h h h 0…999999 0…999999 0…999999 0…9999999 Reset compressor operating hours (line 1) N --- NO / YES Cab20 Cac01 … Cac11 Cac13 Cac14 ---, 01…18, B1…B10 (****) Closed / Open NC / NO Not active / Active … ---, 01…29 (****) 57 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Mask index Cad01 Cad02 Cad03 Cad04 Cad05 Cad06 Cad08 Cad09 Cad10 Cad11 Display description Description Enable suction setpoint Enable setpoint compensation (suction line 1) compensation Enable compensation by Enable setpoint compensation by probe (suction line 1) analog IN Winter offset Offset applied for Winter period Closing offset Offset applied for closing period Enable setpoint compensa- Enable scheduler setpoint compensation (suction line 1) tion by scheduler Activ.Time Bands Day of the week TB1: --:-- -> --:-Time band 1 enabling and definition: start hour and minute, end hour and minute (suction line 1) … … TB4: --:-- -> --:-Time band 4 enabling and definition: start hour and minute, end hour and minute (suction line 1) Changes Time band change action Cae26 Cae27 Cae28 Cae29 NO / YES 0.0 0.0 NO … … --- -999.9…999.9 -999.9…999.9 NO / YES ----- --… MON, TUE, ...SUN … … --- … … … … --- --- Change set by DI ----- Enable setpoint compensation by digital input (suct/cond line 1) Position of the probe for suction pressure setpoint compensation (line1) Type of the probe for suction pressure setpoint compensation (line1) NO --4-20mA ------- --- (display only) max min Enable floating suction setpoint Maximum floating setpoint Minimum floating setpoint Max.setpoint variation admitted Offline decreasing time Compensation value (line 1) Maximum value of compensation (line 1) Minimum value of compensation (line 1) Enable floating setpoint (suction line 1) ------NO … … … --- Max compressor floating setpoint settable (line 1) Minimum compressor floating setpoint settable (line 1) Maximum delta admitted for floating setpoint (suction line 1) … (**) … (**) … (**) … … … … (**) … (**) … (**) Reduction time when supervisor is offline for floating setpoint (suction line 1) 0 min 0…999 NO --- NO / YES …(**) 60 … s NO ACTION --- 0.0 to 99.9 60…9999 NO ACTIONLIMIT TO CURRENT CAPACITYLIMIT CAPACITY TODEC. CAPACITY BY Enable interactions with Enable interactions with pLoads (line 1) pLoads Pressure threshold disabled Suction pressure threshold for disabling pLoads (line 1) Reactivate delay pLoads activation delay, previously disabled by a threshold Config. action 1 Configuration of action associated with the first digital input connected to pLoads (line 1) --- Percentage value to limit capacity to or reduce capacity by if the ''LIMIT CAPACITY TO'' or ''LIMIT CAPACITY BY'' actions have been configured respectively 0.0 (line 1) % 0.0 to 100.0 Config. action 2 Configuration of action associated with the second digital input connected to NO ACTION pLoads (line 1) --- NO ACTIONLIMIT TO CURRENT CAPACITYLIMIT CAPACITY TODEC. CAPACITY BY % 0.0 to 100.0 ----- NO / YES NO / YES --- SINGLE-PHASE/THREE-PHASE V ------- 0 to 999 0.0 to 1.0 NO / YES 0…4/7 (*) … --- Alarm1 description (*) Selection of the first compressor alarm description: Rotation, Oil warning (line … 1) --- Activ.delay Start up delay Reset Priority … Suction pressure/temperature high alarm Threshold Alarm diff. Activation delay for compressor alarm 1 during working (line 1) Activation delay for compressor alarm 1 at start up (line 1) Type of reset for compressor alarm 1 (line 1) Type of priority for compressor alarm 1 (line 1) … Type of high suction pressure/temperature alarm threshold 0 0 AUT. SERIOUS … ABSOLUTE s s ----… --- x (Not available) o (Not selected) x (Selected) x (Not available) o (Not selected) x (Selected) 0…999 0…999 AUT. / MAN. LIGHT / SERIOUS … ABSOLUTE / RELATIVE High suction pressure/temperature alarm threshold High suction pressure/temperature alarm differential … (**) … (**) … … … (**) … (**) Alarm delay Suction pressure/temperature low alarm Threshold Alarm diff. Alarm delay Enable oil temperature alarm management (*) Enable discharge temp. alarm management (*) Enable Low superheat alarm threshold Alarm diff. Switch OFF comp. Reset Alarm delay High suction pressure/temperature alarm delay Type of low suction pressure/temperature alarm threshold 120 ABSOLUTE s --- 0…999 ABSOLUTE / RELATIVE Low suction pressure/temperature alarm threshold Low suction pressure/temperature alarm differential Low suction pressure/temperature alarm delay Enable Digital Scrollä oil temperature alarm (line 1) … (**) … (**) 30 NO … … s --- … (**) … (**) 0…999 NO / YES Enable Digital Scrollä discharge temperature alarm (line 1) NO --- NO / YES Enable alarm/warning+alarme (line 1) Threshold for low superheat alarm (line 1) NO 3,0 --K NO/WARN+ALARM/ONLY ALARM 0.0…99.9 Low superheat alarm differential (line 1) Enable compressor off for low superheat alarm (line 1) Type of low superheat alarm reset (line 1) Low superheat alarm delay (line 1) 1,0 NO MANUAL 30 K ----s 0.0…9,9 NO / YES MANUAL / AUTO 0…999 Voltage Cos(phi) Reset counter Number of alarms for each compressor Alarm1 description Cae03 Cae25 --- --- Cae02 Cae24 NO 0 Load … Values Copy settings to other days Enable supervisor action Enable Cae04 UOM --NO / YES Copy to --- Cae01 Default --CONFIRM&SAVE LOAD PREVIOUS CLEAR ALL MONDAY…SUNDAY; MON-FRI; MON-SAT; SAT&SUN; ALL DAYS NO / YES ---, B1…B10 (****) ---0-1V - 0-10V- 4-20mA- 0-5V -99.9…99.9 -99.9…99.9 -99.9…99.9 NO / YES Cad12 Cad13 NO pRack +0300025EN rel. 1.5 - 17.02.2020 Percentage value to limit capacity to or reduce capacity by if the ''LIMIT CAPACITY TO'' or ''LIMIT CAPACITY BY'' actions have been configured respectively 0.0 (line 1) Enable pLoads action from supervisor (line 1) NO Enable calculation of power consumption NO SINGLE-PHANumber of phases SE Mains voltage 400 Displacement (cosφ) 1.0 Reset current power counter NO Number of alarms for each compressor (line 1) 1/4 (*) Selection of the first compressor alarm description: Generic, Overload, High pressure, Low pressure, Oil (line 1) 58 ENG Mask index Cae30 Cae40 Display description Time of semi-automatic alarm evaluation N° of reties before alarm becomes manual Switch off comp.1 Reset Alarm delay Compressors type Description Time of semi-automatic alarm evaluation for screw compressors out of envelope (line 1) Number of retries before alarm becomes manual (line 1) 2 UOM min 0…999 3 --- 0…9 Enable compressor 1 off for compressor inverter warning (line 1) Type of compressor inverter warning reset (line 1) Compressor inverter warning activation delay (line 1) Type of compressors (line 1) NO MANUAL 0 RECIPROCATING ----s --- Compressors number Cmp1,… Number of compressors (line 1) Enable compressors (line 1) 2/3 (*) DIS ----- NO / YES MANUAL/AUTO 0…999 RECIPROCATING SCROLL SCREW 1…6/12 (*) DIS / EN Refrigerant type Type of refrigerant (suction Line 1) R404A --- Min on time Min off time Min time to start same compressor Ignition type Minimum compressor on time (line 1) Minimum compressor off time (line 1) Minimum time between same compressor starts (line 1) 30 120 360 s s s Type of compressors start up DIRECT --- Star time Star line delay Star delta delay Partwinding delay Equalization Equalizat.time Devices rotation type Star relay run time Delay between star and line relay Delay between star and delta relay Partwinding delay Enable compressors equalization at start up Equalization duration Type of rotation 0 0 0 0 NO 0 FIFO ms ms ms ms --s --- Dev. unload sequence Unloader sequence in relation to compressor activation (C=compressor, p=unloader) CpppCppp --- Load up time Load down time Unloader delay Custom rotation Switch ON order Custom rotation Switch OFF order Modulate speed device Delay between different compressor starts Delay between different compressor stops Delay between stages Order of switch ON for compressor custom rotation 10 0 0 1 s s s --- DIRECT PART WINDING STAR DELTA 0…9999 0…9999 0…9999 0…9999 NO / YES 0…999 -----FIFO LIFO TIME CUSTOM -------CCpppppp CpppCppp 0…999 0…999 0…999 1…16 Order of switch OFF for compressor custom rotation 1 --- 1…16 Compressor driver type (line 1) NONE --- Min. frequency Max. frequency Min on time Min off time Min time to start same compressor Digital Scrollä comp. valve regulation Minimum inverter frequency 30 Maximum inverter frequency 60 Compressor controlled by inverter minimum ON time (line 1) 30 Compressor controlled by inverter minimum OFF time (line 1) 60 Compressor controlled by inverter minimum time between same compressor 180 starts (line 1) Digital Scrollä comp. valve control type (line 1) OPTIMISED CONTROL Hz Hz s s s NONE INVERTER DIGITAL SCROLL CONTINUOUS SCREW 0…150 0…150 0…999 0…999 0…999 Cycle time Oil dilution Disch.temper. Compr.Manufacturer Cycle time value (line 1) Digital Scrollä, enable oil temperature alarm (line 1) Digital Scrollä, enable discharge temperature alarm (line 1) Compressor manufacturer for screw compressors 13 ENABLE ENABLE GENERIC s ------- Compressor series Number of valves Stages configuration Compressor series Number of valves used for capacity control Stage configuration for screw compressor 1 …(***) 3 25/50/75 /100 ----% Enable common delay time (from one stage to the following) for screw ENABLE compressor 1 Common time/time betwe- Common delay time (from one stage and the following) for screw compressor 0 en steps 1 From…to… Minimum compressor delay time in order to reach each capacity stage from … previous for screw compressor 1 Intermittent valve time Intermittent on/off time for capacity control valves for screw compressor 1 10 Valve conf. Configuration of the behaviour of the valves during start/stop and stages for … screw compressor 1 --- Caf02 Caf03 Default Caf04 Caf05 Caf06 Caf07 Caf08 Caf09 Caf10 Caf11 Caf12 Caf13 Caf14 Caf15 Caf16 Caf17 Caf18 Caf19 --- Caf20 Caf21 Common time Caf22 Caf23 Caf24 Caf25 Caf26 Caf27 Limit comp.permanence at Enable time limit at minimum capacity for screw compressor 1 min power Max.perman.time Max time for compressor operation at minimum capacity for screw compressor 1 Limitat.on for Time to return to minimum after the compressor was forced to second stage after staying at minimum for max. time for screw compressor 1 Min.output power Minimum compressor capacity in case of high capacity range (usually 25%), only for continuous compressors Compressor start-up phase Start-up phase time (after electric start-up) duration Maximun time to reach Maximum time in order to reach maximum compressor capacity (continuous -maximum power capacity control) -minimum power Minimum time in order to reach minimum compressor capacity (continuous capacity control) 59 Values R22 - R134a - R404A - R407C R410A - R507A - R290 - R600 R600a - R717 -R744 - R728 - R1270 - R417A - R422D -R413A - R422A - R423A - R407A - R427A - R245Fa - R407F - R32 0…999 0…999 0…999 OPTIMISED CONTROL VARIABLE CYCLE TIME FIXED CYCLE TIME 12…20 DISABLE/ENABLE DISABLE/ENABLE GENERIC / BITZER REFCOMP / HANBELL …(***) 1…4 100; 50/100; 50/75/100; 25/50/75/100; 33/66/100 DISABLE/ENABLE s 0…999 s 0…999 s --- ENABLE --- 60 s 0…99 O (ON) X (OFF) I (Intermittent) P (Pulsing) DISABLE ENABLE 0…9999 0 s 0…9999 25 % 0…100 10 s 0…999 120 s 0…999 120 s 0…999 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Mask index Display description Intermittent Pulse period Min.Puls.Incr. Max.Puls.Incr. Min.Puls.Decr. Max.Puls.Decr. Valve conf. Description Intermittent on/off time for capacity control valves Pulsing period for valves (for continuous compressors) Minimum pulse time for increase capacity (valves control) Maximum pulse time for increase capacity (valves control) Minimum pulse time for decrease capacity (valves control) Maximum pulse time for decrease capacity (valves control) Configuration of the behaviour of the valves during start/stop, incr.min% to 100%, decr.100% to min%, standby, decr.100% to 50% Number of valves Stages configuration Number of control capacity valves for screw compressor 2 Stage configuration for screw compressor 2 Caf90 … Different sizes Different number of valves S1 … Enable compressors of different sizes (line 1) Enable compressor capacity control (line 1) Enable size and size for compressor group 1 (line 1) Caf91 … S4 … Enable size and size for compressor group 4 (line 1) S1 Enable stages and stages for compressor group 1 (line 1) YES 100 … S4 … Enable stages and stages for compressor group 4 (line 1)) C01 … C12 Min on time Min off time Min time to start same compressor Reactivate start-up procedure after Minimum voltage Maximum voltage Nominal freq. Nominal power Size group for compressor 1 (line 1) or presence of inverter … Size group for compressor 6 (line 1) Minimum Digital ScrollTM compressor On time (line 1) Minimum Digital ScrollTM compressor Off time(line 1) Minimum time between starts for Digital ScrollTM compressor (line 1) … NO --S1 … S1 60 180 360 … --kW --… --s s s Values 0…99 1…10 0.0…9,9 0.0…9,9 0.0…9,9 0.0…9,9 O (ON) X (OFF) I (Intermittent) P (Pulsing) 1…4 100; 50/100; 50/75/100; 25/50/75/100; 33/66/100 … NO / YES NO / YES NO / YES 0.0…500.0 … --NO / YES 0.0…500.0 NO/YES 100; 50/100; 50/75/100; 25/50/75/100; 33/66/100 … NO / YES S1…S4 S1…S4/INV … S1…S4 0…999 0…999 0…999 Digital ScrollTM compressor start-up procedure reactivation time (line 1) 480 min 0…9999 0.0 10.0 50 10.0 V V Hz kW 0.0…10.0 0.0…10.0 0…150 0.0…500.0 90 30 YES s s --- 0…600 0…600 NO / YES NO --- NO / YES 50.0 % 0.0…100.0 NO --- NO / YES NO --- NO / YES --------… ----… --- ---, 01…18, B1…B10 (****) Closed / Open NC / NO Not active / Active … PRESSURE / TEMPERATURE PROPORTIONAL BAND NEUTRAL ZONE … 0…999999 Caf28 Caf29 Caf36 … Caf92 Caf93 Caf95 Cag01 Cag02 Cag03 Cag04 Cag05 Cag06 Cag07 Voltage corresponding to the minimum capacity of the inverter (line 1) Voltage corresponding to the maximum capacity of the inverter (line 1) Nominal frequency (nominal capacity at nominal frequency) (line 1) Nominal capacity for compressor managed by inverter at nominal frequency (line 1) Rising time Time to pass from min capacity to max capacity for modulat. device (line 1) Falling time Time to pass from max capacity to min capacity for modul. device (line 1) Enable compressor modula- Enable compressor 1 modulation inside Neutral zone (line 1) tion inside neutral zone Enable suction press.backup Enable screens for suction pressure backup probe configuration probe (line 1) Request in case of regulat. Compressor forcing value in case of suction probes fault (line 1) probe fault Enable anti liquid return Enable liquid non return function (line 1) valve Enable compressor envelop Enable compressor envelope management (screw only). management (*) For details on configuration contact Carel. The following parameters refer to line 2, for details see the corresponding parameters for line 1 above DI Alarm 1 for compressor 1 DI position (line 2) Status (display only) Status of alarm 1 for compressor 1 DI (line 2) Cba01 Logic Logic of alarm 1 for compressor 1 DI (line 2) Function (display only) Alarm 1 for compressor 1 function status (line 2) … … … Regulation by Compressor control by temperature or pressure (line 2) Regulation type Compressor control type (line 2) Cbb01 … Cbc01 … Cbd01 … Cbe01 … Cbg01 … 3 25/50/ 75/100 … NO NO YES 10.0 … NO UOM s s s s s s --- --% … ------kW … ----kW --% … Working hours Compressor 1 … Enable suction setpoint compensation Enable compensation by analog IN … Number of alarms for each compressor … Compressors type … Compressor 1 max operating hours (line 2) 03 --NC --… PRESSURE NEUTRAL ZONE … --- … Enable setpoint compensation (suction line 2) … NO … --- … NO / YES Enable setpoint compensation by probe (suction line 2) NO --- NO / YES … Number of alarms for each compressor (line 2) … 1 … --- … 0 to 4 … Type of compressors (line 2) … --- Compressors number … Minimum voltage Maximum voltage Number of compressors (line 2) … Voltage corresponding at the minimum capacity of the inverter (line 2) Voltage corresponding at the maximum capacity of the inverter (line 2) … RECIPROCATING 2/3 (*) … 0.0 10.0 … RECIPROCATING SCROLL 1…12 … 0.0…10.0 0.0…10.0 Nominal freq. Nominal frequency (nominal capacity at nominal frequency) (line 2) 50 Hz 0…150 Nominal power Nominal capacity for compressor managed by inverter at nominal frequency (line 2) … 10.0 kW 0.0…500.0 … … … Cbf02 … Default 10 3 0,5 1,0 0,5 1,0 … … pRack +0300025EN rel. 1.5 - 17.02.2020 60 --… Hz Hz ENG Mask index Display description Description Default UOM Values D.Condensers (The I/Os available depend on the selected configuration, the following are just some examples. For the complete list of I/O positions available see Appendix A.5) DI Fan 1 overload DI position (line 1) … -----, 01…18, B1…B10 (****) Status (display only) Status of fan 1 overload DI (line 1) ----Closed / Open Daa01 Logic Logic of fan 1 overload DI (line 1) NC --NC / NO Function (display only) Fan 1 overload function status (line 1) ----Not active / Active … … … … … … --Condenser probe position (line 1) B1 -----, B1…B10 (****) ---0-1V --Condenser probe type (line 1) 4-20mA --0-10V 4-20mA Daa39 0-5V --- (display only) Condensing pressure value (line 1) --… …(**) Max limit Maximum condensing pressure value (line 1) 30,0 barg … …(**) Min limit Minimum condensing pressure value (line 1) 0,0 barg … …(**) Calib. Condensing pressure probe calibration (line 1) 0,0 barg … …(**) … … … … … … DO Fan 1 DO position (line 1) 03 -----, 01…29 (****) Status (display only) Status of fan 1 DO (line 1) ----Closed / Open Daa21 Logic Logic of fan 1 DO (line 1) NC --NC / NO Function (display only) Fan 1 function status (line 1) ----Not active / Active … … … … … … AO Inverter fan AO position (line 1) 0 -----, 01…06 (****) FCS1*-CONFCS1*-CONVONOFF; " -----";" Daa38 Type (****) Type of output, PWM / phase control per AO fan inverters (line 1) --VONOFF MCHRTF*";" FCS3*-CONV010" Status (display only) Inverter fan output value (line 1) 0 % 0.0…100.0 … … … … … … Regulation by Condenser control by temperature or pressure (line 1) PRESSURE --PRESSURE/TEMPERATURE Regulation type Condenser control type (line 1) PROPORTI. --PROPORTIONAL BAND Dab01 BAND NEUTRAL ZONE Minimum Condenser setpoint lower limit (line 1) … (**) … … (**) Dab02 Maximum Condensers setpoint higher limit (line 1) … (**) … … (**) Dab03 Setpoint Condenser setpoint (line 1) … (**) … … (**) Fans work only when at Enable fan operation linked to compressor operation NO --NO / YES Dab04 least one compressor works Cut_Off enable Enable fan cut-off function NO --NO / YES Dab05 Cut-Off request Diff. Hysteresis Reg.type Cut-off value Cut-off differential Cut-off hysteresis Type for proportional control (condenser line 1) 0.0 … (**) … (**) PROP. % … … --- 300 … (**) … (**) … (**) … (**) NO … (**) 15 s … … … … --… s 0.0…100.0 … (**) … (**) PROP. PROP.+INT. 0…999 … (**) … (**) … (**) … (**) NO / YES … (**) 0…9999 90 s 0…9999 30 s 0…9999 180 s 0…9999 NO --- NO / YES 0.0 0.0 NO … … --- -999.9…999.9 -999.9…999.9 NO / YES ----- --… MON, ...SUN … … --- … … … … --- --- 0 --- NO --- --CONFIRM&SAVE LOAD PREVIOUS CLEAR ALL MONDAY…SUNDAY; MON-FRI; MON-SAT; SAT&SUN; ALL DAYS NO / YES 0.0 … -9.9…9.9 NO --- NO / YES NO ABSOLUTE ----- NO / YES ABSOLUTE / RELATIVE 24.0 barg 1.0 barg … … … (**) … (**) 60 ABSOLUTE s --- 0…999 ABSOLUTE / RELATIVE 7.0 barg … … (**) Dab6/ Dab8 (**) Integral time Integral time for prop. control (cond. line 1) Differential Differential for proportional control (cond. line 1) NZ diff. Neutral zone control differential (line 1) Dab10/Dab11 (**) Activ.diff. Neutral zone control differential for device activation (line 1) Deact.diff. Neutral zone control differential for device deactivation (line 1) En.force off power Enable capacity immediate decreasing to 0 (line 1) Dab12/Dab13 (**) Setp.for force off Threshold for capacity decreasing to 0 (line 1) Power load to 100% min Minimum time to increase capacity request to 100%, Neutral zone control time (condenser line 1) Dab14 Power load to 100% max Maximum time to increase capacity request to 100%, Neutral zone control time (condenser line 1) Power unload to 0% min Minimum time to decrease capacity request to 0%, Neutral zone control time (condenser line 1) Dab15 Power unload to 0% max Maximum time to decrease capacity request to 0%, Neutral zone control time (condenser line 1) Enable condensing setpoint Enable setpoint compensation (condenser line 1) Dad01 compensation Winter offset Enable setpoint compensation (condenser line 1) Dad02 Closing offset Offset applied for Winter period Enable setpoint compensa- Enable scheduler setpoint compensation (condenser line 1) Dad03 tion by scheduler Activ.Time Bands Day of the week TB1: --:-- -> --:-Time band 1 enabling and definition: start hour and minute, end hour and minute (suction line 1) … … TB4: --:-- -> --:-Time band 4 enabling and definition: start hour and minute, end hour and minute (suction line 1) Dad04 Changes Time band changes action Dab7/ Dab9 (**) Copy to Dad05 Dad06 Dad07 Dae01 Dae02 Dae03 Copy settings to other days Enable floating condensing Enable floating setpoint (condenser line 1) setpoint Offset for external tempe- Temperature delta for floating setpoint (condenser line 1) rature Controlled by: Enable floating condensing from digital input -Digital input Change set by digital input Enable setpoint compensation by digital input (suction/condensing line 1) Cond.pressure/temperature Type of high condensing pressure/temperature alarm threshold (line 1) high alarm Threshold High condensing pressure/temperature alarm threshold (line 1) Cond.pressure/temperature High condensing pressure/temperature alarm differential (line 1) alarm diff. Alarm delay High condensing pressure/temperature alarm delay (line 1) Cond.pressure/temperature Type of low condensing pressure/temperature alarm threshold low alarm (line 1) Threshold Low condensing pressure/temperature alarm threshold (line 1) 61 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Mask index Display description Description Default UOM Values Cond.pressure/temperature Low condensing pressure/temperature alarm differential (line 1) alarm diff. Alarm delay Low condensing pressure/temperature alarm delay (line 1) Common fan overload Common fan overload (line 1) Delay Common fan overload alarm activation delay Reset Type of common fan overload alarm reset Number of present fans Number of fans (line 1) Fan1, Fan2, … Enable fans 1 to 12 (line 1) Fan13, Fan14, … Enable fans 13 to 16 (line 1) Refrigerant type Type of refrigerant (condenser line 1) 1.0 barg … … (**) 30 YES AUTOMATIC 0 3 EN EN R404A s ----s --------- Devices rotation type Type of rotation devices (condenser line 1) FIFO --- Custom rotation Switch ON order Custom rotation Switch OFF order Modulate speed device Switch ON order for fans with custom rotation (condenser line 1) 1 --- 0…999 NO / YES AUTOMATIC / MANUAL 0 to 500 0 to 16 DIS / EN DIS / EN R22 - R134a - R404A - R407C R410A - R507A - R290 - R600 R600a - R717 -R744 - R728 - R1270 - R417A - R422D -R413A - R422A - R423A - R407A - R427A - R245Fa - R407F - R32 -----FIFO LIFO TIME CUSTOM 1…16 Switch OFF order for fans with custom rotation (condenser line 1) 1 --- 1…16 Fan driver type (line 1) NONE --- Type of output, PWM / phase control for condenser modulating device (line 1) ---- --- NO 0.0 10.0 60 100 1200 --V V % % s NONE INVETER PHASE CONTROL ---MCHRTF* FCS3*-CONV010 NO / YES 0.0 to 9.9 0.0 to 99.9 0…100 0…999 0 to 32000 1200 s 0 to 32000 1 NO --- ------- 0 to 16 NO / YES NO / YES ----10.0 °C ----… NO / YES NO / YES -99.9…99.9 2.5 °C CUSTOM … --- Only when enabling type is GREATER THAN or LESS THAN, number of fans to consider for splitting (line 1) Disable split condenser when high condensing pressure prevent occurs (line 1) Duration of split condenser deactivation for high condensing pressure prevent (line 1) Enable silencer (line 1) Maximum request allowed when silencer function is active (line 1) Silencer controlled by digital input (condenser line 1) 0 --- -99.9…99.9 CUSTOM ODD EVEN GREATER THAN LESS THAN 0 to 16 NO --- NO / YES 0 h 0 to 24 DISAB. 75.0 % NO --% --- DISABLE / ENABLE 0.0…100.0 NO / YES NO ----- ----… NO / YES MON, ..., SUN … … --- … … … … Changes Silencer controlled by scheduler (condenser line 1) Day of the week Time band 1 enabling and definition: start hour and minute, end hour and minute (condenser line 1) … Time band 4 enabling and definition: start hour and minute, end hour and minute (condenser line 1) Time band changes action --- --- Copy to Copy settings to other days 0 --- Speed Up Speed Up time Ext.Temp.Manage Ext.Temp.Thresh. Enable speed up (condenser line 1) Speed up time (condenser line 1) Enable speed up management by outside temperature (condenser line 1) Outside temperature threshold for speed up management (condenser line 1) Outside temperature differential for speed up management (condenser line 1) Enable the screens for condensing pressure backup probe configuration (condenser line 1) Value of fans forcing in case of condensing probes fault (line 1) YES 5 DIS 25.0 °C --s --… --CONFIRM&SAVE LOAD PREVIOUS CLEAR ALL MONDAY…SUNDAY; MON-FRI; MON-SAT; SAT&SUN; ALL DAYS NO / YES 0…60 DIS / EN -99.9…99.9 2.5 °C … -99.9…99.9 NO --- NO / YES 50.0 % 0.0…100.0 The following parameters refer to line 2, for details see the corresponding parameters for line 1 above DI Fan 1 overload DI position (line 2) Status (display only) Status of fan 1 overload DI (line 2) Logic Logic of fan 1 overload DI (line 2) Dba01 Function (display only) Fan 1 overload function status (line 2) … --NC --- --------- … … … ---, 01…18, B1…B10 (****) Closed / Open NC / NO Not active Active … Dae04 Dae05 Daf01 Daf02 Daf03 Daf04 Daf05 Daf07, Daf08 Daf09, Daf10 Dag01 Type (****) Dag02 Neutral zone reg. Min.out value Max.out value Min. power refer. Max. power refer. Rising time Dag03 Falling time Dag04 Num.control.fans Split Condenser Controlled by: -Digital input -External temp. -Scheduler Est. Temp.Thr. Dag05 Est. Temp.Diff. Type Fan control also inside Neutral zone (line 1) Minimum voltage for compressor inverter (line 1) Maximum voltage for compressor inverter (line 1) Minimum capacity of fan modulating device (line 1) Maximum capacity of fan modulating device (line 1) Time to pass from min capacity to max capacity for fan modulating device (line 1) Time to pass from max capacity to min capacity for fan modulating device (line 1) Number of fans under inverter (only for alarm enabling) Enable split condenser (line 1) Split Condenser controlled by digital input (line 1) Split Condenser controlled by outside temperature (line 1) Split Condenser controlled by scheduler (line 1) Split condenser by outside temperature management setpoint (line 1) Split condenser by outside temperature management differential (line 1) Fans enabled with split condenser (line 1) Dag06 --- Dag09 Dag10 Disable split condenser as first stage of HP pressostat for Anti-noise Max output Controlled by: -Digital input -Scheduler Activ.Time Bands TB1: --:-- -> --:-… TB4: --:-- -> --:-- Dag12 Dag13 Ext.Temp.Diff. Dag14 Dag15 Enable condensing press. backup probe Request in case of egulat. probes fault … pRack +0300025EN rel. 1.5 - 17.02.2020 … 62 ENG Mask index Dbb01 … Dbd01 … Dbe01 … Dbf01 … Display description Regulation by Regulation type Description Condenser control by temperature or pressure (line 2) Condenser control type (line 2) … … Enable condensing setpoint Enable setpoint compensation (condenser line 2) compensation … … Cond.temperature/pressure Type of high condensing pressure/temperature alarm threshold high alarm (line 2) Threshold High condensing pressure/temperature alarm threshold (line 2) … … Number of present fans Number of fans (line 2) … … Modulate speed device Fan driver type (line 2) Default UOM PRESSURE NEUTRAL ZONE … NO ----… --- … ABSOLUTE … --- 24,0 barg … 3 … NONE … … --… --- Dbg01 … Type (****) Type of output, PWM / phase control for condenser modulating device (line 2) ---- --- … … … … Mask index Display description Description Default Values PRESSURE TEMPERATURE PROPORTIONAL BAND NEUTRAL ZONE … NO YES … ABSOLUTE RELATIVE … (**) … 0 to 16 … NONE INVETER PHASE CONTROL ---MCHRTF* FCS3*-CONV010 … UOM Values E.Other funct. (The I/Os available depend on the selected configuration, the following are just some examples. For the complete list of I/O positions available see Appendix A.5) Eaaa04 … Eaaa45 ----- Oil temperature probe position (line1) Oil temperature probe type (line 1) B1 4-20mA ----- --- (display only) Upper value Lower value Calibration … DO Status (display only) Logic Function (display only) Common oil cooler Oil pumps number Oil temperature probe value (line 1) Oil temperature probe max. limit (line 1) Oil temperature probe min. limit (line 1) Oil temperature probe adjustment (line 1) … Oil level valve DO position, compressor 6 (line 1) Oil level valve DO status, compressor 6 (line 1) Oil level valve DO logic, compressor 6 (line 1) Oil level function status, compressor 6 (line 1) Enable common oil cooling (line 1) Number of oil pumps for common oil cooler (line 1) --30.0 barg 0.0 barg 0.0 barg … 03 --NC --YES 0 … … … … … ------------- Enable Aout pump Enable AO of common oil cooler pump (line 1) YES --- Setpoint Differential Pump start delay Oil pumps number Common oil cooler setpoint (line 1) Common oil cooler differential (line 1) Time delay before the start-up of pump 2 after pump1 turns on (line 1) Screw compressors: number of oil cooler pumps enabled (line1) 0.0 °C 0.0 °C 0 0 … … s --- Enable Aout pump Screw compressors: enable AO for oil cooler pump (line 1) YES --- Setpoint Differential Threshold Differential Delay En.oil lev.manag. Num.Alarm oil level Time open Time close DO Status (display only) Logic Function (display only) Subcooling control --- Screw compressors: oil temperature setpoint (line 1) Screw compressors: oil temperature differential (line 1) Common oil high temperature alarm threshold (line 1) Common oil high temperature alarm differential (line 1) Common oil high temperature alarm delay (line 1) Enable oil level management (line 1) Number of compressor alarm associated with oil level (line 1) Oil level valve opening time (line 1) Oil level valve closing time (line 1) Subcooling valve DO position (line 1) Status of subcooling valve DO (line 1) Logic of subcooling valve (line 1) Subcooling valve function status (line 1) Enable subcooling function (line 1) Subcooling control type (line 1) °C/°F °C/°F °C/°F °C/°F s ----s s ------------- Threshold Subcool.value (display only) ----- Threshold for subcooling control (line 1) Subcooling value (line 1) 0.0 0.0 100.0 °C 10.0 °C 0 NO 0 0 0 … --NO --NO BY COND. & LIQUID TEMP. 0.0 °C 0.0 °C Discharge temperature probe position, compressor 1 (line 1) Type of discharge temperature probe, compressor 1 (line 1) B1 4-20mA ----- --- (display only) Upper value Lower value Calibration … DO Status (display only) Logic Function (display only) Economizer Compr.Power Thr. Press.Lim. Disch.T.Thr. Economizer Setpoint Discharge temperature value, compressor 1 (line 1) Maximum discharge temperature value, compressor 1 (line 1) Minimum discharge temperature value, compressor 1 (line 1) Discharge temperature probe calibration, compressor 1 (line 1) … Economizer valve DO position, compressor 6 (line 1) Economizer valve DO status, compressor 6 (line 1) Economizer valve DO logic, compressor 6 (line 1) Economizer valve function status, compressor 6 (line 1) Enable economizer function (line 1) Capacity percentage threshold for economizer activation (line 1) Condensing temperature threshold for economizer activation (line 1) Discharge temperature threshold for economizer activation (line 1) Enable economizer function for screw compressor 1 (line 1) Setpoint for economizer function with discharge temperature for screw compressor 1 Differential for economizer function with discharge temperature for screw compressor 1 --30.0 barg 0.0 barg 0.0 barg … … --NO --NO 0 0.0 °C 0.0 °C NO … (**) … … … … … ----------% … … --… ---, B1…B10 (****) --NTC - PT1000 - 0-1V - 0-10V4-20mA - 0-5V - HTNTC … (**) … (**) … (**) … (**) … ---, 01…29 (****) Closed / Open NC / NO Not active / Active NO / YES 0…100 -999.9…999.9 -999.9…999.9 NO / YES … (**) … (**) … … (**) Eaab04 Eaab05 Eaab06 Eaab07 Eaab08 Eaab09 Eaab10 Eaab11 Ebaa01 Ebab01 Ecaa01 … Ecaa12 Ecab04 (*) Ecab05 (*) Differential 63 … … ---, B1…B10 (****) --NTC - PT1000 - 0-1V - 0-10V 4-20mA - 0-5V - HTNTC … (**) … (**) … (**) … (**) … ---, 01…29 (****) Closed / Open NC / NO Not active / Active NO / YES 0 to 1 (Analog output) 0 to 2 (Digital outputs) NO (Digital outputs) YES (Analog output) … (**) -9.9…9.9 0…999 0 to 1 (Analog output) 0 to 2 (Digital outputs) NO (Digital outputs) YES (Analog output) … … … … 0 to 32767 NO / YES 0 to 4/7 (*) 0…999 0…999 ---, 01…29 (****) Closed / Open NC / NO Not active / Active NO / YES BY COND.& LIQUID TEMP. ONLY BY LIQUID. TEMP. -9999.9…9999.9 -999.9…999.9 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Mask index Ecab06 (*) Display description Min.power activ. Cond.press.check ----- Description Default Minimum screw compressor 1 capacity for economizer activation 75 Enable economizer function with condensing temperature for screw DIS compressor 1 Setpoint for economizer function with condensing temperature for screw 60.0 compressor 1 Differential for economizer function with condensing temperature for screw 5.0 compressor 1 Discharge temperature probe position, compressor 1 (line 1) B1 Compressor 1 discharge temperature probe position (line1) 4-20mA --- (display only) Upper value Lower value Calibration … DO Status (display only) Logic Function (display only) Liquid Injection Threshold Differential DI Status (display only) Logic Compressor 1 discharge temperature probe type (line 1) Compressor 1 discharge temperature probe value (line 1) Compressor 1 discharge temperature probe max. limit (line 1) Compressor 1 discharge temperature probe min. limit (line 1) Compressor 1 discharge temperature probe adjustment (line 1) Injection valve DO position, compressor 6 (line 1) Injection valve DO status, compressor 6 (line 1) Injection valve DO logic, compressor 6 (line 1) Injection valve function status, compressor 6 (line 1) Enable liquid injection function (line 1) Liquid injection set point (line 1) Liquid injection differential (line 1) Heat recovery from digital input DI position (line 1) Status of heat recovery DI (line 1) Logic of heat recovery DI (line 1) --30.0 barg 0.0 barg 0.0 barg … … --NO --DIS 70.0 °C 5,0 … --NC Function (display only) DO Status (display only) Logic Function (display only) AO Status of heat recovery from digital input DI function (line 1) Heat recovery pump DO position (line 1) Heat recovery pump DO status (line 1) Heat recovery pump DO logic (line 1) Heat recovery pump status (line 1) Heat recovery damper AO position (line 1) Type of output, PWM / phase control for heat recovery damper AO (line 1) Heat recovery damper AO status (line 1) Heat recovery outlet temperature probe position (line 1) Type of heat recovery outlet temperature probe (line 1) ------------NC ----------FCS1*-CONVO--NOFF ----B1 --4-20mA --- Setpoint Differential Edaa01 … Edaa12 Edab01/ Edab03 (*) Eeaa02 Eeaa03 Eeaa04 Type (****) Status ----- Eeaa05 Eeab01 Eeab02 Eeab03 Eeab04 Eeab05 Eeab06 Eeab07 Efa05 Efa06 Efa07 Efa08 Efa09 … Efb05 Efb06 Efb07 --- (display only) Heat recovery outlet temperature value (line 1) Upper value Maximum heat recovery outlet temperature value (line 1) Lower value Minimum heat recovery outlet temperature value (line 1) Calibration Heat recovery outlet temperature probe calibration (line 1) Enable Heat Reclaim Enable heat recovery function (line 1) Condensing pressure Lower Condensing pressure lower limit for heat recovery (line 1) Limit Modulation by temperat. Enable heat recovery control by discharge temperature (line 1) Setpoint Heat recovery: discharge temperature setpoint (line 1) Differential Heat recovery: discharge temperature differential (line 1) Disable floating condensing Disable floating condensing pressure when heat reclaim is active pressure Setpoint offset Offset that must be applied to the condensing setpoint instead of floating condensing when heat reclaim is active Enable heat recovery control by scheduler (line 1) Enable activation by scheduler Active.Time Bands Week of the day TB1: --:-- -> --:-Time band 1 enabling and definition: start hour and minute, end hour and minute (condenser line 1) … … TB4: --:-- -> --:-Time band 4 enabling and definition: start hour and minute, end hour and minute (condenser line 1) Changes Time band changes action % --- UOM Values 0; 25; 50; 75; 100 DIS / EN °C/°F … °C/°F … ----- --30.0 barg 0.0 barg 0.0 barg NO 0.0 barg … … … … --… ---, B1…B10 (****) --NTC - PT1000 - 0-1V - 0-10V4-20mA - 0-5V - HTNTC … (**) … (**) … (**) … (**) … ---, 01…29 (****) Closed / Open NC / NO Not active / Active DIS / EN … (**) … (**) ---, 01…18, B1…B10 (****) Closed / Open NC NO Not active / Active ---, 01…29 Closed / Open NC / NO Not active / Active ---, 01…29 ---FCS1*-CONVONOFF MCHRTF* FCS3*-CONV010 ---, B1…B10 (****) --NTC - PT1000 - 0-1V - 0-10V4-20mA - 0-5V - HTNTC … (**) … (**) … (**) … (**) NO / YES … (**) NO 0.0 °C 0.0 °C NO --… … --- NO / YES … (**) 0.0 ... 99.9 NO / YES --- … -99.9…99.9 NO --- NO / YES ----- --… MON, ..., SUN … … --- … … … … --- --- --CONFIRM&SAVE LOAD PREVIOUS CLEAR ALL MONDAY…SUNDAY; MON-FRI; MON-SAT; SAT&SUN; ALL DAYS DISABLE / ENABLE … DISABLE / ENABLE … DIRECT / REVERSE … SKIP / CHANGE … … (**) … (**) DISABLE / ENABLE … (**) 0…9999 LIGHT / SERIOUS DISABLE / ENABLE … (**) 0…9999 LIGHT / SERIOUS … DISABLE / ENABLE DISABLE / ENABLE … DIRECT / REVERSE … SKIP / CHANGE … … … … … … ----------… … ------- Copy to Copy settings to other days 0 --- Gen.Funct.1 … Gen.Funct.5 Regulation variable Mode Enable Description --------------Setpoint Differential High alarm High alarm Delay time Alarm type Low alarm Low alarm Delay time Alarm type … Gen.Modulat.1 Gen.Modulat.2 Regulation variable Mode Enable Description --------------- Enable generic stage function 1 .. Enable generic stage function 5 Control variable for generic stage function 1 Direct or reverse control Enabling variable for generic stage function 1 Enable description change Description Setpoint for generic stage function 1 Differential for generic stage function 1 High alarm enabling for generic stage function 1 High alarm threshold for generic stage function 1 High alarm delay for generic stage function 1 Low alarm enabling for generic stage function 1 Low alarm threshold for generic stage function 1 Low alarm delay for generic stage function 1 Low alarm delay for generic stage function 1 Type of low alarm for generic stage function 1 … Enable generic modulating function 1 management Enable generic modulating function 2 management Control variable for generic modulating function 1 Direct or reverse modulation Enabling variable for generic modulating function 1 Enable description change Description DISAB. … DISAB. --DIRECT --SKIP --0.0 °C 0.0 °C DISAB. 0.0 °C 0 LIGHT DISAB. 0.0 °C 0 LIGHT … DISAB. DISAB. --DIRECT --SKIP --- --… ------------… … --… s ----… s --… --------------- pRack +0300025EN rel. 1.5 - 17.02.2020 64 ENG Mask index Efb08 Efb09 Efb010 Efb20 … Efc05 Efc06 Efc07 … Efd05 Efd06 Efd07 Efe05 Efe06/Efe07 (**) … Efe16 … Efe21 … Efe29 … Egaa01 Egaa02 Egab01 Egab02 Egab03 Egab04 Ehb01 Ehb03 Ehb04 Display description Description Setpoint Setpoint for generic modulating function 1 Differential Differential for generic modulating function 1 High alarm High alarm enabling for generic modulating function 1 High alarm High alarm threshold for generic modulating function 1 Delay time High alarm delay for generic modulating function 1 Alarm type Low alarm enabling for generic modulating function 1 Out upper limit Output upper limit for generic modulating function 1 Out lower limit Output lower limit for generic modulating function 1 Enable cutoff Enable cut off function for generic modulating function 1 Cutoff diff. Cut off differential for generic modulating function 1 Cutoff hys. Cut off hysteresis for generic modulating function 1 Low alarm Low alarm enabling for generic modulating function 1 Low alarm Low alarm threshold for generic modulating function 1 Delay time Low alarm delay for generic modulating function 1 Alarm type Low alarm type for generic modulating function 1 … … Gen.alarm 1 Enable generic alarm function 1 management Gen.alarm 2 Enable generic alarm function 2 management Regulation variable Monitored variable for generic alarm function 1 Enable Enabling variable for generic alarm function 1 Description Enable description change --------------Description Alarm type Alarm type for generic alarm function 1 Delay time Delay for generic alarm function 1 … … Generic Function Scheduler Enable generic scheduler function Gen.funct.scheduling con- Generic scheduler function considers the same special days and periods of nected to global scheduling global scheduler Enable Enabling variable for generic scheduler function Activ.Time Bands Day of the week TB1: --:-- -> --:-Time band 1 enabling and definition: start hour and minute, end hour and minute (suction line 1) … … TB4: --:-- -> --:-Time band 4 enabling and definition: start hour and minute, end hour and minute (suction line 1) Changes Time band changes action Default 0.0 °C 0.0 °C DISAB. 0.0 °C 0 LIGHT 100.0 0.0 NO 0.0 °C 0.0 °C DISAB. 0.0 °C 0 LIGHT … DISAB. DISAB. ----SKIP --LIGHT 0 … DISAB. NO … … --… s --% % --… … --… s --… --------------s … ----- Values … (**) … (**) DISABLE / ENABLE … (**) 0…9999 LIGHT / SERIOUS 0…100 0…100 NO / YES … (**) … (**) DISABLE / ENABLE … (**) 0…9999 LIGHT / SERIOUS … DISABLE / ENABLE DISABLE / ENABLE … … SKIP / CHANGE … LIGHT / SERIOUS 0…9999 … DISABLE / ENABLE NO / YES ------- ----… … MON, ..., SUN … … --- … … … … --- --- Copy to Copy settings to other days 0 --- Gen.A Measure … ------- (display only) Upper value Lower value Calibration ... DI Status (display only) Logic Function (display only) ... DO Status (display only) Logic Function (display only) … Modulating.1 Generic analogue input A unit of measure selection … Generic probe A position Generic probe A type Generic probe A value Generic probe A max. limit Generic probe A min. limit Generic probe A adjustment ... Generic digital input F DI position Status of generic digital input F DI Logic of generic digital input F DI Status of generic digital input F DI ... Generic stage 1 DO position Status of generic stage 1 DO Logic of generic stage 1 DO Generic stage 1 DO function status … Generic modulating 1 AO position Type of output, PWM / phase control for generic modulating function 1 AO (line 1) Generic modulating 1 output value … ChillBooster fault DI position (line 1) Status of ChillBooster fault DI (line 1) Logic of ChillBooster fault DI (line 1) Status of ChillBooster fault (line 1) ChillBooster DO position (line 1) Status of ChillBooster DO (line 1) Logic of ChillBooster DO (line 1) Status of ChillBooster function (line 1) Enable ChillBooster function (line 1) Fan capacity under which ChillBooster is deactivated (line 1) °C --… … B1 --4-20mA ----… 30.0 barg … 0.0 barg … 0.0 barg … … … --------NC ------… … … ------NO ------… … 0 --FCS1*-CONVO--NOFF 0 % … … --------NC ------… ------NO ------NO --95 % --CONFIRM&SAVE LOAD PREVIOUS CLEAR ALL MONDAY…SUNDAY; MON-FRI; MON-SAT; SAT&SUN; ALL DAYS °C; °F; barg; psig; %; ppm … ---, B1…B10 (****) … (**) … (**) … (**) … (**) … (**) … ---, 01…18, B1…B10 (****) Closed / Open NC / NO Not active / Active … ---, 01…29 (****) Closed / Open NC / NO Not active / Active … ---, 01…06 (****) FCS1*-CONVONOFF; "-----";" MCHRTF*";" FCS3*-CONV010" 0.0…100.0 … ---, 01…18, B1…B10 (****) Closed / Open NC / NO Not active / Active ---, 01…29 (****) Closed / Open NC / NO Not active / Active NO / YES 0…100 Type (****) Status (display only) … DI Status (display only) Logic Function (display only) DO Status (display only) Logic Function (display only) Device present Deactivation when fanspower falls under 5 Fans work at maximum capacity at least for this time before Before the activation fans ChillBooster activation (line 1) at max for Ext.Temp.Thr. Outside temperature threshold for ChillBooster activation (line 1) 30.0 °C Sanitary proc. Enable hygiene procedure (line 1) Disab. start at Hygiene procedure starting time (line 1) 00:00 Duration Hygiene procedure duration (line 1) 0 Ext.temp.thr Outside temperature threshold for hygiene procedure activati. (line 1) 5,0 °C ChillBooster requires main- ChillBooster maximum running time (line 1) 200 tenance after Reset maintenance time ChillBooster maintenance time reset (line 1) NO Avoid simultaneous pulses Enable simultaneous compressor start up inhibition NO betw.lines Delay Delay between start up for compressors on different lines 0 Force off L2 Comp.s for line Enable line 2 compressor switch OFF due to line 1 compressor fault NO 1 fault Delay Delay for line 2 compressor switch off after serious alarm on line 1 compres- 0 sors Switch on L1 Comp.s for L2 Enable line 1 compressor switch ON due to line 2 compressor NO activation switch ON Switch on period Delay for line1 compressor switch on for line 2 compressor switch on 30 Force off line 2 if line 1 is off Enable line 2 compressor switch OFF due to line 1 switch OFF NO 65 UOM min 0 to 300 … ----min … h … (**) DISABLE / ENABLE … 0 to 30 … (**) 0…999 ----- NO / YES NO / YES s --- 0…999 NO / YES s 0…999 --- NO / YES s --- 0…999 NO / YES pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Mask index Ehb05 Eia02 Eia04 Eib02 Eib04 Eic02 Eic03 Display description Description Enable min threshold for L1 Enable L1 activation by DSS only when suction pressure is greater than a activation minimum threshold Threshold Minimum threshold for line 1 activation by DSS Setpoint SH PID control set point (valve 1) LowSH thres. Low superheat protection threshold (valve 1) LOP thresh. Low operating pressure protection threshold (valve 1) MOP thresh. Maximum operating pressure protection threshold (valve 1) Setpoint SH PID control set point (valve 2) LowSH thres. Low superheat protection threshold (valve 2) LOP thresh. Low operating pressure protection threshold (valve 2) MOP thresh. Maximum operating pressure protection threshold (valve 2) Enable manual Enable manual positioning (valve 1) Valve position Manual valve position: Manual position (valve 1) Enable manual Enable manual positioning (valve 2) Valve position Manual valve position: Manual position (valve 2) S1 offset Probe S1 reading offset (valve 1) S1 probe (display) Value read by probe S1 (valve 1) S2 offset Probe S2 reading offset (valve 1) S2 probe (display) Value read by probe S2 (valve 1) S3 offset Probe S3 reading offset (valve 1) S3 probe (display) Value read by probe S3 (valve 1) S4 offset Probe S4 reading offset (valve 1) S4 probe (display) Value read by probe S4 (valve 1) Alarm: Abilita l’allarme sonda S1 ( valvola 1 ) EN. Default NO / YES --11.0 5.0 -50.0 50.0 11.0 5.0 -50.0 50.0 … K K ----K K ----- … (**) -40.0…180.0 -40.0…180.0 -60.0… 200.0 -60.0… 200.0 -40.0…180.0 -40.0…180.0 -60.0… 200.0 -60.0… 200.0 --- Min / Max NO 0 0 0.0 --0.0 --0.0 --0.0 --- Min.: Max.: Alarm min.: Alarm max.: Alarm: EN. Minimum probe S1 reading (valve 1) Maximum probe S1 reading (valve 1) Minimum probe S1 alarm threshold (valve 1) Maximum probe S1 alarm threshold (valve 1) Enable probe S2 alarm (valve 1 ) -1.0 9.3 -1.0 9.3 Type: Type of probe S2 (valve 1) CAREL NTC Alarm min.: Alarm max.: Alarm: EN. Minimum probe S2 alarm threshold (valve 1) Maximum probe S2 alarm threshold (valve 1) Enable probe S3 alarm (valve 1) -50.0 105.0 Type: Type of probe S3 (valve 1) 4-20mA Min.: Max.: Alarm min.: Alarm max.: Alarm: EN. Minimum probe S3 reading (valve 1) Maximum probe S3 reading (valve 1) Minimum probe S3 alarm threshold (valve 1) Maximum probe S3 alarm threshold (valve 1) Enable probe S4 alarm (valve 1) -1.0 30.0 -1.0 30.0 Type: Type of probe S4 (valve 1) CAREL NTC Alarm min.: Alarm max.: Minimum probe S4 alarm threshold (valve 1) Maximum probe S4 alarm threshold (valve 1) -50.0 105.0 ID1 configuration: Configuration of action of digital input 1 on driver (valve 1) REG. BACKUP ID2 configuration: Configuration of action of digital input 2 on driver (valve 1) DISABLED Eic09 DI1: DI2: Digital input 1 status (valve 1) Digital input 2 status (valve 1) ----- Eic10 Valve A relay config.: Configuration of digital output1 (valve 1) ALARM RELAY Eic11 Valve B relay config.: Configuration of digital output 2 (valve 1) ALARM RELAY S1 offset S1 probe (display) S2 offset S2 probe (display) S3 offset S3 probe (display) S4 offset S4 probe (display) Alarm: EN. Probe S1 reading offset (valve 2) Value read by probe S1 (valve 2) Probe S2 reading offset (valve 2) Value read by probe S2 (valve 2) Probe S3 reading offset (valve 2) Value read by probe S3 (valve 2) Probe S4 reading offset (valve 2) Value read by probe S4 (valve 2) Enable probe S1 alarm (valve 2) 0.0 --0.0 --0.0 --0.0 --- Type: Type of probe S1 (valve 2) 4-20mA Min.: Max.: Alarm min.: Alarm max.: Alarm: EN. Minimum probe S1 reading (valve 2) Maximum probe S1 reading (valve 2) Minimum probe S1 alarm threshold (valve 2) Maximum probe S1 alarm threshold (valve 2) Enable probe S2 alarm (valve 2) -1.0 9.3 -1.0 9.3 Type: Type of probe S2 (valve 2) CAREL NTC Alarm min.: Alarm max.: Minimum probe S2 alarm threshold (valve 2) Maximum probe S2 alarm threshold (valve 2) -50.0 105.0 Eic07 NO/YES --Min / Max Barg/psig Barg/psig °C/°F °C/°F Barg/psig Barg/psig °C/°F °C/°F EN./DIS. 4-20mA Eic06 NO/YES NO Type of probe S1 (valve 1) Eic05 Barg/pisg Barg/pisg Barg/pisg Barg/pisg 4-20mA / 4-20mA REMOTE / 4-20mA EXTERNAL / 0-5V RAT. -20.0...200.0 -20.0...200.0 -20.0...200.0 -20.0...200.0 °C/°F °C/°F CAREL NTC / 0-10V EXT. SIGNAL / NTC SPKP**T0 / CAREL NTC-HT -60.0...200.0 -60.0...200.0 Barg/pisg Barg/pisg Barg/pisg Barg/pisg 4-20mA / 4-20mA REMOTE / 4-20mA EXTERNAL / 0-5V RAT. -20.0...200.0 -20.0...200.0 -20.0...200.0 -20.0...200.0 EN./DIS. EN./DIS. EN./DIS. °C/°F °C/°F Eic08 Eic12 Eic13 Eic14 Eic15 pRack +0300025EN rel. 1.5 - 17.02.2020 Values --- Type: Eic04 UOM NO CAREL NTC / NTC SPKP**T0 / CAREL NTC-HT -60.0...200.0 -60.0...200.0 DISABLED / REG. SAFETY / REG. BACKUP / START/STOP REG. / VALVE FORCED 100% OPEN / BATTERY ALARM MNG. / VALVE REGULATION OPT. AFTER DEFROST DISABLED / REG. SAFETY / REG. BACKUP / START/STOP REG. / VALVE FORCED 100% OPEN / BATTERY ALARM MNG. / VALVE REGULATION OPT. AFTER DEFROST DISABLED / ALARM RELAY / SOLENOID VALVE RELAY / VALVE + ALARM RELAY / REVERSED ALARM RELAY / VALVE POSITION RELAY DISABLED / ALARM RELAY / SOLENOID VALVE RELAY / VALVE + ALARM RELAY / REVERSED ALARM RELAY / VALVE POSITION RELAY Barg/psig Barg/psig °C/°F °C/°F Barg/psig Barg/psig °C/°F °C/°F EN./DIS. Barg/pisg Barg/pisg Barg/pisg Barg/pisg 4-20mA / 4-20mA REMOTE / 4-20mA EXTERNAL / 0-5V RAT. -20.0...200.0 -20.0...200.0 -20.0...200.0 -20.0...200.0 °C/°F °C/°F CAREL NTC / 0-10V EXT. SIGNAL / NTC SPKP**T0 / CAREL NTC-HT -60.0...200.0 -60.0...200.0 EN./DIS. 66 ENG Mask index Display description Alarm: EN. Enable probe S3 alarm (valve 2) Type: Type of probe S3 (valve 2) 4-20mA Min.: Max.: Alarm min.: Alarm max.: Alarm: EN. Minimum probe S3 reading (valve 2) Maximum probe S3 reading (valve 2) Minimum probe S3 alarm threshold (valve 2) Maximum probe S3 alarm threshold (valve 2) Enable probe S4 alarm (valve 2) -1.0 30.0 -1.0 30.0 Type: Type of probe S4 (valve 2) CAREL NTC Alarm min.: Alarm max.: Minimum probe S4 alarm threshold (valve 2) Maximum probe S4 alarm threshold (valve 2) -50.0 105.0 ID1 configuration: Configuration of action of digital input 1 on driver (valve 2) REG. BACKUP ID2 configuration: Configuration of action of digital input 2 on driver (valve 2) DISABLED Eic19 DI1: DI2: Digital input 1 status (valve 2) Digital input 2 status (valve 2) ----- Eic20 Valve A relay config.: Configuration of digital output1 (valve 2) ALARM RELAY Eic21 Valve B relay config.: Configuration of digital output 2 (valve 2) ALARM RELAY Eid02 Valve A opening at start-up Valve A opened in stand-by Start-up delay after defrost Valve A preposit. delay Prop Gain: Integral time: Derivat.time: LowSH protect.: LOP protection: MOP protection: Threshold: Integr.time: Alarm timeout LowSH: LOP: MOP: Threshold Timeout Valve A opening at start-up Valve A opened in stand-by Start-up delay after defrost Valve A preposit. delay Prop Gain: Integral time: Derivat.time: LowSH protect.: LOP protection: MOP protection: Threshold: Integr.time: Alarm timeout LowSH: LOP: MOP: Threshold Timeout Min.steps Max.steps Closing steps Min.steps Max.steps Closing steps Enable EVD in PLB x EVD valves number EVS 1 Address EVS 2 Address Valve opening at start of control (valve 1) Enable valve opening with control not active (valve 1) Start control delay after defrost (valve 1) Stationary time when valve pre-positions (valve 1) Control proportional gain (valve 1) Control integral time (valve 1) Control derivative time (valve 1) Integral time with low superheat protection (valve 1) Integral time with low operating pressure protection (valve 1) Integral time with maximum operating pressure protection (valve 1) High condensing temperature protection activation threshold (valve 1) Integral time with high condensing temperature protection (valve 1) High condensing temperature alarm delay (valve 1) Low superheat alarm delay (valve 1) Low operating pressure alarm delay (valve 1) Maximum operating pressure alarm delay (valve 1) Low suction temperature protection threshold (valve 1) Low suction temperature alarm delay (valve 1) Valve opening at start of control (valve 2) Enable valve opening with control not active (valve 2) Start control delay after defrost (valve 2) Stationary time when valve pre-positions (valve 2) Control proportional gain (valve 2) Control integral time (valve 2) Control derivative time (valve 2) Integral time with low superheat protection (valve 2) Integral time with low operating pressure protection (valve 2) Integral time with maximum operating pressure protection (valve 2) High condensing temperature protection activation threshold (valve 2) Integral time with high condensing temperature protection (valve 2) High condensing temperature alarm delay (valve 2) Low superheat alarm delay (valve 2) Low operating pressure alarm delay (valve 2) Maximum operating pressure alarm delay (valve 2) Low suction temperature protection threshold (valve 2) Low suction temperature alarm delay (valve 2) Minimum step configuration, valve 1 Maximum step configuration, valve 1 Closing step configuration, valve 1 Minimum step configuration, valve 2 Maximum step configuration, valve 2 Closing step configuration, valve 2 Enable the EVD management on current board Number of drivers managed Serial address of driver 1 50 NO 10 6 15.0 150 5.0 10.0 10.0 20.0 30.0 0.5 600 300 300 600 -50.0 300 50 NO 10 6 15.0 150 5.0 10.0 10.0 20.0 30.0 0.5 600 300 300 600 -50.0 300 50 480 500 50 480 500 NO 1 198 Serial address of driver 2 199 0…207 Defaults: Force Parameters: Regulation based on: Run driver parameter setting procedure Override driver parameter settings Select cooling capacity used for control NO NO LINE 1 COMP LINE 1 COMP. / LINE 2 COMP Eic16 Eic17 Eic18 Eid04 Eid06 Eid08 Eid10 Eid11 Eid13 Eid15 Eid17 Eid19 Eid21 Eid23 Eid24 Eid26 Eie02 Eie04 Eif01 Eif02 Description Default UOM Values EN./DIS. 4-20mA / 4-20mA REMOTE / 4-20mA EXTERNAL / 0-5V RAT. Barg/pisg -20.0...200.0 Barg/pisg -20.0...200.0 Barg/pisg -20.0...200.0 Barg/pisg -20.0...200.0 EN./DIS. 67 °C/°F °C/°F % min s s s s s s °C/°F s s s s s °C/°F s % min s s s s s s °C/°F s s s s s °C/°F s CAREL NTC / NTC SPKP**T0 / CAREL NTC-HT -60.0...200.0 -60.0...200.0 DISABLED / REG. SAFETY / REG. BACKUP / START/STOP REG. / VALVE FORCED 100% OPEN / BATTERY ALARM MNG. / VALVE REGULATION OPT. AFTER DEFROST DISABLED / REG. SAFETY / REG. BACKUP / START/STOP REG. / VALVE FORCED 100% OPEN / BATTERY ALARM MNG. / VALVE REGULATION OPT. AFTER DEFROST DISABLED / ALARM RELAY / SOLENOID VALVE RELAY / VALVE + ALARM RELAY / REVERSED ALARM RELAY / VALVE POSITION RELAY DISABLED / ALARM RELAY / SOLENOID VALVE RELAY / VALVE + ALARM RELAY / REVERSED ALARM RELAY / VALVE POSITION RELAY 0…100 NO/YES 0…60 0…18000 0.0…800.0 0…1000 0…1000 0.0…800.0 0.0…800.0 0.0…800.0 -60.0…200.0 0.0…800.0 0…18000 0…18000 0…18000 0…18000 -60.0…200.0 0…18000 0…100 NO/YES 0…60 0…18000 0.0…800.0 0…1000 0…1000 0.0…800.0 0.0…800.0 0.0…800.0 -60.0…200.0 0.0…800.0 0…18000 0…18000 0…18000 0…18000 -60.0…200.0 0…18000 0…9999 0…9999 0…9999 0…9999 0…9999 0…9999 NO/YES 1/2 0…207 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Mask index Eif03 Display description Description Default Valve: Type of valve connected to the driver Main Regulation: Main control for the valve, for details refer to manual +0300005EN Auxiliary regulation: Safety or auxiliary control CAREL EXV Auxiliary refrigerant: Refrigerant used for P -> T conversion of probe S3 with high condensing temperature protection R744 S1 probe alarm manag: Type of action in the event of probe S1 fault VALVE AT FIXED POS. S2 probe alarm manag: Type of action in the event of probe S2 fault VALVE AT FIXED POS. Eif11 DC power supply Configure the type of power supply used for the driver NO Eif12 Valve: Type of valve connected to the driver CAREL EXV Eif05 Eif06 UOM R404 CONDENSER FOR SUBCRITICAL CO2 INVERSE HIGH CONDENS. TEMP. PROTECTION ON S3 Possible control functions in manual +0300005EN Possible control functions in manual +0300005EN NO ACTION / VALVE FORCE CLOSED / VALVE AT FIXED POS / USE BACKUP S3 NO ACTION / VALVE FORCE CLOSED / VALVE AT FIXED POS / USE BACKUP S4 NO / YES USER DEFINED / CAREL EXV / ALCO EX4 / ALCO EX5 / ALCO EX6 / ALCO EX7 / ALCO EX8 CAREL RECOMMENDED / ALCO EX8 ALCO SPECIFICATION / SPORLAN SEI 0.5-11 / SPORLAN SER 1.5-20 / SPORLAN SEI 30 / SPORLAN SEI 50 / SPORLAN SEH 100 / SPORLAN SEH 175 / Danfoss ETS 12.5-25B / Danfoss ETS 50B / Danfoss ETS 100B / Danfoss ETS 250 / Danfoss ETS 400 / TWO CAREL EXV TOGETHER / SPORLAN SER(I) G, J, K / Danfoss CCM 10-20-30 / Danfoss CCM 40 Eif09 Main control for the valve, for details refer to manual +0300005EN Auxiliary regulation: Safety or auxiliary control Auxiliary refrigerant: Refrigerant used for P -> T conversion of probe S3 with high condensing temperature protection R744 S1 probe alarm manag: Type of action in the event of probe S1 fault VALVE AT FIXED POS. S2 probe alarm manag: Type of action in the event of probe S2 fault VALVE AT FIXED POS. Eif14 Eif15 R404 CONDENSER FOR SUBCRITICAL CO2 INVERSE HIGH CONDENS. TEMP. PROTECTION ON S3 Main Regulation: Possible control functions in manual +0300005EN Possible control functions in manual +0300005EN NO ACTION / VALVE FORCE CLOSED / VALVE AT FIXED POS / USE BACKUP S3 NO ACTION / VALVE FORCE CLOSED / VALVE AT FIXED POS / USE BACKUP S4 NO / YES Eif18 Eif20 DC power supply Configure the type of power supply used for the driver The following parameters refer to line 2, for details see the corresponding parameters for line 1 above --Oil temperature probe position (line 2) --Oil temperature probe type (line 2) Eaba04 … Eabb04 … Ebba01 … Ebbb01 … Values USER DEFINED / CAREL EXV / ALCO EX4 / ALCO EX5 / ALCO EX6 / ALCO EX7 / ALCO EX8 CAREL RECOMMENDED / ALCO EX8 ALCO SPECIFICATION / SPORLAN SEI 0.5-11 / SPORLAN SER 1.5-20 / SPORLAN SEI 30 / SPORLAN SEI 50 / SPORLAN SEH 100 / SPORLAN SEH 175 / Danfoss ETS 12.5-25B / Danfoss ETS 50B / Danfoss ETS 100B / Danfoss ETS 250 / Danfoss ETS 400 / TWO CAREL EXV TOGETHER / SPORLAN SER(I) G, J, K / Danfoss CCM 10-20-30 / Danfoss CCM 40 NO --- (display only) Upper value Lower value Calibration … Oil pumps number Oil temperature probe value (line 2) Oil temperature probe max. limit (line 2) Oil temperature probe min. limit (line 2) Oil temperature probe adjustment (line 2) … Number of oil pumps for common oil cooler (line 2) --30.0 barg 0.0 barg 0.0 barg … 0 … … … … … --- Enable Aout pump Enable AO of common oil cooler pump (line 2) YES --- … DO Status (display only) Logic Function (display only) … Subcooling control --- … Subcooling valve DO position (line 2) Status of subcooling valve DO (line 2) Logic of subcooling valve (line 2) Subcooling valve function status (line 2) … Enable subcooling function (line2) Subcooling control type (line 2) … --------… ----- Threshold Subcool.value (display only) … Threshold for subcooling control (line 2) Value of subcooling (line 2) … … --NO --… NO COND& LIQUID TEMP. 0.0 °C 0.0 °C … … ---, B1…B10 (****) --NTC - PT1000 - 0-1V - 0-10V 4-20mA - 0-5V - HTNTC … (**) … (**) … (**) … (**) … 0 to 1 (digital input) 0 to 2 (Digital outputs) NO (Digital outputs) YES (digital input) … ---, 01…29 (****) Closed / Open NC / NO Not active / Active … NO / YES COND&LIQUID TEMP. LIQUID TEMP. ONLY -9999.9…9999.9 -999.9…999.9 … … … … pRack +0300025EN rel. 1.5 - 17.02.2020 68 B1 4-20mA ----- ENG Mask index Ecbb04 … Display description Economizer Compr.Power Thr. Press.Lim. Disch.T.Thr. … ----- Description Enable economizer function (line 2) Capacity percent threshold for economizer activation (line 2) Condensing temperature threshold for economizer activation (line 2) Discharge temperature threshold for economizer activation (line 2) … Compressor 1 discharge temperature probe position (line 2) Compressor 1 discharge temperature probe type (line 2) Default NO 0 0.0 °C 0.0 °C … B1 4-20mA --% … … … ----- UOM --- (display only) Upper value Lower value Calibration … Liquid Injection Threshold Differential … DI Status Logic Function Enable Heat Reclaim … DI Status Logic Function … Device present Deactivation when fanspower falls under … Compressor 1 discharge temperature probe value (line 2) Compressor 1 discharge temperature probe max. limit (line 2) Compressor 1 discharge temperature probe min. limit (line 2) Compressor 1 discharge temperature probe adjustment (line 2) … Enable liquid injection function (line 2) Liquid injection setpoint (line 2) Liquid injection differential (line 2) … Heat recovery from digital input DI position (line 2) Status of heat recovery DI (line 2) Logic of heat recovery DI (line 2) Status of heat recovery from digital input DI function (line 2) Enable heat recovery function (line 2) … ChillBooster fault DI position (line 2) Status of ChillBooster fault DI (line 2) Logic of ChillBooster fault DI (line 2) Status of ChillBooster fault DI (line 21) … ChillBooster function enable (line 2) Fans capacity under which ChillBooster is deactivated (line 2) --30.0 barg 0.0 barg 0.0 barg … DIS 70.0 °C 5,0 … … --NC --NO … ----NC --… NO 95 … … … … … --… … … ----------… --------… --% Values NO / YES 0…100 -999.9…999.9 -999.9…999.9 … ---, B1…B10 (****) --NTC - PT1000 - 0-1V - 0-10V 4-20mA - 0-5V - HTNTC … (**) … (**) … (**) … (**) … DIS / EN … (**) … (**) … ---, 01…18, B1…B10 (****) Closed / Open NC / NO Not active / Active NO / YES … ---, 01…18, B1…B10 (****) Closed / Open NC / NO Not active / Active … NO / YES 0…100 … … … … Edba01 Edba01 … Edbb01 … Eeba02 Eebb01 … Egba01 … Egbb01 … Mask index Display description F.settings Summer/Winter Faaa01 Special days Holiday periods Begin Faaa02 End Faaa03 Day 01 … … Faaa04 Day 10 P1 --… Faaa05 P5 --Date format Description Default UOM Enable Summer/Winter period management (line 1) Enable special days management (line 1) Enable holiday period management (line 1) Summer period beginning date (line 1) Summer period end date (line 1) Special day 1 date (line 1) … Special day 10 date (line 1) Holiday period P1 beginning date (line 1) Holiday period P1 end date (line 1) … Holiday period P5 beginning date (line 1) Holiday period P5 end date (line 1) Date format NO NO NO ------… ------… ----DD/MM/YY ------------… ------… ------- Hour Date Day (display only) Daily saving time Transition time Start, ... End, ... Language Disable language mask at start-up Countdown Main mask selection Hour and minute Date Day of the week calculated from current date Enable daylight saving time Offset time Starting week, day and month and hour for daylight saving time End week, day and month and hour for daylight saving time Current language Disable the change language screen at start-up … … … DISABLE 60 … … ENGLISH YES … … … ----… … ----- Starting value for countdown, time change language screen active. Main screen selection 60 LINE 1 s --- Address Protocol Address of the controller in a supervisory system network (line 1) Supervisor communication protocol (line 1) 196 pRACK MANAGER ----- Baudrate Address Protocol Supervisor communication baud rate (line 1) Address of the controller in a supervisory system network (line 1) Supervisor communication protocol (line 1) 19200 1 ----- CAREL --- 19200 0000 --NO 0000 1234 1234 --------------- Faab01 Faab02/Faab03/ Faab04 Faab05 Fb01 Fb02 Fb03 Fca01 Fca02 Fd01 Fd02 Fd03 Baudrate Insert password Logged as (display only) Logout User Service Manufacturer Supervisor communication baud rate (line 1) Password Current password level Logout User password Service password Manufacturer password Values NO / YES NO / YES NO / YES 01/Gen…31/Dic 01/Gen…31/Dic 01/Gen…31/Dic … 01/Gen…31/Dic 01/Gen…31/Dic 01/Gen…31/Dic … 01/Gen…31/Dic 01/Gen…31/Dic ---DD/MM/YY MM/DD/YY YY/MM/DD … … Monday… Sunday DISABLE / ENABLE 0 to 240 … … … NO / YES 0…60 LINE 1 / LINE 2 DOUBLE SUCTION DOUBLE CONDENSER 0 to 207 -CAREL SLAVE LOCAL CAREL SLAVE REMOTE MODBUS SLAVE pRACK MANAGER CAREL SLAVE GSM 1200 to 19200 0…207 --CAREL SLAVE LOCAL MODBUS SLAVE pRACK MANAGER 1200…19200 0…9999 User, Service, Manufacturer NO / YES 0…9999 0…9999 0…9999 The following parameters refer to line 2, for details see the corresponding parameters for line 1 above 69 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Mask index Display description Address Protocol Description Enable summer/winter period management (line 2) Enable special days management (line 2) Default 196 pRACK MANAGER Baudrate Address Protocol Enable holiday period management (line 2) Enable summer/winter period management (line 2) Enable special days management (line 2) 19200 1 Baudrate Enable holiday period management (line 2) 19200 Fcb01 MODBUS SLAVE Fcb01 Mask index Display description Description UOM Values --0 to 207 ----, CAREL SLAVE LOCAL CAREL SLAVE REMOTE MODBUS SLAVE pRACK MANAGER CAREL SLAVE GSM --1200 to 19200 --0…207 ---, CAREL SLAVE LOCAL --MODBUS SLAVE pRACK MANAGER --1200…19200 Default UOM Values G.Safety Gba01 Prevent enable Setpoint Differential Decrease compressor power time Enable Heat Reclaim as first prevent step Offset HeatR. Enable ChillBooster as first prevent step Offset Chill. Prevent max.num Prevent max.number evaluation time Reset automatic prevent Gba02 Gba03 Gba04 Gba05 Max.num prevent Gba07 Enable condensing pressure prevent (line 1) Condensing pressure prevent threshold (line 1) Condensing pressure prevent differential (line 1) Decreasing capacity time (line 1) NO 0.0 barg 0.0 barg 0 --… … s NO / YES … (**) 0.0 to 99.9 0…999 Enabling heat recovery as first stage for condensing HP prevent (line 1) Offset between heat recovery and prevent setpoint (line 1) Enable ChillBooster as first stage for condensing HP prevent (line 1) NO --- NO / YES 0.0 barg NO … --- 0.0 to 99.9 NO / YES Offset between ChillBooster and prevent setpoint (line 1) Maximum number of prevent allowed before locking compressor (line 1) Prevent maximum number evaluation time 0.0 barg 3 60 … --h 0.0 to 99.9 1…5 0…999 Reset number of prevent (line 1) Maximum number of prevent allowed before locking compressor (line 1, auxiliary regulation) Tempo di valutaz.num.max Prevent maximum number evaluation time (auxiliary regulation) prevent Riabilita prevent automatico Reset number of prevent (line 1, auxiliary regulation) Threshold: Threshold for low pressure prevent with auxiliary regulation Band: Differential for the prevent re-enter Minimum Power request: Minimum power request in prevent Align Pow.Req at the end of At the end of prevent action power requst is calculated starting from the last prevent request value and not from the value available before the prevent action Use Suction UoM Unit selection for prevent threshold and differential Gba08 Gba09 Common HP type Type of reset for common HP alarm (line 1) Common HP delay Common high pressure delay (line 1) Common LP start delay Low common condensing pressure delay at start up (line 1) Common LP delay Low common condensing pressure delay during operation (line 1) Time of semi-automatic Period of LP evaluation (line 1) alarm evaluation N° of reties before alarm Number of LP in period after which the alarm becomes manual becomes manual (line 1) Liquid alarm delay Liquid level alarm delay (line 1) Oil alarm delay Common oil alarm delay (line 1) Output alarms relays activa- Select alarm relay output activation for active alarms or alarms not reset tion with Gca01 Gca02 Gca03 Gca04 Gca05 The following parameters refer to line 2, for details see the corresponding parameters for line 1 above Gbb01 Prevent enable Enable condensing pressure prevent (line 2) … … … Common HP type Type of reset for common HP alarm (line 2) Gcb01 Common HP delay Common high pressure delay (line 2) … … … Mask index Display description NO --- NO / YES 3 --- 1…5 60 h 0…999 NO 0.5 0.1 20.0 --NO / SI Barg/psig -1.0…150.0 Barg/psig 0.0…60.0 % 0.0…100.0 NO NO / YES NO NO / YES AUTO 10 60 20 120 --s s s min AUTO / MAN 0…999 0…999 0…999 0…999 5 --- 0…999 0 s 0 s Active alarms 0…999 0…999 Active alarms Alarms not reset NO … AUTO 10 … NO / YES … AUTO / MAN 0…999 … Description --… --s … Default UOM Values H.Info H01 (display only) H02 (display only) Mask index Ver. Bios Boot Board type Board size Total flash RAM Built-In type Main cycle Software version and date Bios version and date Boot version and date Type of hardware Hardware size Flash memory size RAM size Type of built-in display Number of cycles per second and software cycle time Display description Description … … … … … --------- ----------kB kB --cycles/s ms Default UOM … … … … … … … None / PGD1 … Values I.Setup Pre-configuration Pre-configuration selected 01. RS2 --- Boards necessary Suction line Condenser line pLAN boards required for the selected pre-configuration Number of suction lines featured in the pre-configuration Number of condenser lines featured in the pre-configuration ------- ------- Ia01 Ia02 (disp. only) Ia03 (disp. only) pRack +0300025EN rel. 1.5 - 17.02.2020 70 --NOT USED— 01. RS2 02. RS3 03. RS3p 04. RS3i 05. RS4 06. RS4i 07. SL3d --0 to 2 0 to 2 08. SL5d 09. SW1 10. SW2 11. SW3 12. d-RS2 13. d-RS3 14. d-RS4 ENG Mask index Default … RECIPROCATING … RECIPROCATING 1/4 (*) EN EN EN SUCTION + CONDENSER °C/barg RECIPROCATING UOM ------------------- Compressors number Number of compressors (line 1) Number of alarms for each Number of alarms for each compressor (line 1) compressor Modulate speed device Modulating speed device for first compressor (line 1) 2/3 (*) 1 ----- None --- Compressors sizes Compressors sizes (line 1) SAME CAPACITY & SAME STAGE CONF. --- S1 Enable size and size for compressor group 1 (line 1) … S4 … Enable size and size for compressor group 4 (line 1) S1 Enable stages and stages for compressor group 1 (line 1) YES 10.0 … NO --YES 100 --kW … --kW --% … S4 … Enable stages and stages for compressor group 4 (line 1)) … NO --- … --kW C01 … C12 Compr.Manufacturer Size group for compressor 1 (line 1) or presence of inverter … Size group for compressor 12 (line 1) Compressor manufacturer for screw compressors S1 … S1 Generic --… ----- Compressor series Compressors sizes S1 Compressor series Compressor sizes (line 1) Enable size and size for compressor group 1 (line 1) Ib16 … S4 … Enable size and size for compressor group 4 (line 1) …(***) SAME CAPACITY YES --… NO --- ------kW … --kW --- --C01 … C06 Compressors sizes S1 Size group for compressor 1 (line 1) or presence of inverter … Size group for compressor 12 (line 1) Compressors sizes (line 1) Enable size and size for compressor group 1 (line 1) … S4 … Enable size and size for compressor group 4 (line 1) C01 … C12 Regulation by Measure unit Refrigerant Size group for compressor 1 (line 1) or presence of inverter … Size group for compressor 6 (line 1) Compressor control by temperature or pressure (line 1) Unit of measure (line 1) Type of refrigerant (suction Line 1) S1 … --SAME CAPACITY YES --… NO --S1 … S1 PRESSURE barg R404A --… ------kW … --kW --… --------- Regulation type Compressor control type (line 1) NEUTRAL ZONE Ia04 (display only) Ia05 (display only) Ib01 Ib02 Display description Num.Comp. L1 Comp.type L1 Num.Comp. L2 Comp.type L2 Num.alarms per comp. Cond.Gen.Alarm HP comm.pressostat LP comm.pressostat Type of Installation Description Number of compressors featured in the pre-configuration (line 1) Type of compressors featured in the pre-configuration (line 1) Number of compressors featured in the pre-configuration (line 2) Type of compressors featured in the pre-configuration (line 2) Number of alarms for compressor featured in the pre-configuration Enable common condenser alarm Enable common HP pressure switch Enable common LP pressure switch Type of system Measure Units Compressors type Unit of measure Type of compressors (line 1) ----- Ib03 Ib04 Ib05 Ib30 Ib34 Ib35 Ib36 Ib10 Ib11 Ib17 Ib20 Ib21 Ib22 Ib45 Ib50 Ib51 NO 3,5 barg 0,3 barg NO NO --- NO / YES RECIPROCATING 3 1 ------- RECIPROCATING / SCROLL 1…12 0 to 4 NONE --- Compressors sizes Compressors sizes (line 1) SAME CAPACITY --- S1 Enable size and size for compressor group 1 (line 1) … S4 … Enable size and size for compressor group 4 (line 1) YES --… NO --- --kW … --kW NONE INVERTER ---/DIGITAL SCROLL(*) SAME CAPAC.&SAME STAGE CONF. SAME CAPAC.&DIFF. STAGE CONF. DEFINE SIZES NO / YES 0.0…500.0 … NO / YES 0.0…500.0 Ib52 Ib70 Ib74 NO / YES 0.0…500.0 … NO / YES 0.0…500.0 NO / YES 100; 50/100; 50/75/100; 25/50/75/100; 33/66/100 … NO / YES 100; 50/100; 50/75/100; 25/50/75/100; 33/66/100 S1…S4/INV … S1…S4 GENERIC BITZER REFCOMP HANBELL …(***) SAME CAPACITY / DEFINE SIZES NO / YES 0.0…500.0 … NO / YES 0.0…500.0 Enable integral time action Enable integral time for proportional suction line control (line 1) Setpoint Setpoint without compensation (suction line 1) Differential Differential (suction line 1) Configure another suction Second suction line configuration line Dedicated pRack board for Suction lines on different boards suction line Compressors type Type of compressors (line 2) Compressors number Number of compressors (line 2) Number of alarms for each Number of alarms for each compressor (line 2) compressor Modulate speed device Modulating speed device for first compressor (line 2) Ib41 Ib43 NONE / INVERTER ---/DIGITAL SCROLL(*) ---/STEPLESS*) SAME CAPAC&SAME STAGE CONF. SAME CAPAC.&DIFF. STAGE CONF. DEFINE SIZES S1…S4/INV … S1…S4 SAME CAPACITY / DEFINE SIZES NO / YES 0.0…500.0 … NO / YES 0.0…500.0 S1…S4/INV … S1…S4 PRESSURE / TEMPERATURE … R22 - R134a - R404A - R407C R410A - R507A - R290 - R600 R600a - R717 -R744 - R728 - R1270 - R417A - R422D -R413A - R422A - R423A - R407A - R427A - R245Fa - R407F - R32 --PROPORTIONAL BAND NEUTRAL ZONE --NO / YES … (**) … (**) … (**) … (**) --NO / YES Ib40 Ib42 Values 1…12 RECIPROCATING / SCROLL SCREW 1…12 RECIPROCATING / SCROLL 0 to 4/7 (*) EN/DIS EN/DIS EN/DIS SUCTION / CONDENSER SUCTION + CONDENSER °C/barg / °F/psig RECIPROCATING SCROLL / SCREW 1…6/12 (*) 0 to 4/7 (*) 71 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Mask index Ib75 Ib76 Ib60 Ib61 Ib62 S1 Display description Description Enable stages and stages for compressor group 1 (line 1) Default … S4 … Enable stages and stages for compressor group 4 (line 1)) C01 … C12 Compressors sizes Size group for compressor 1 (line 1) or presence of inverter … Size group for compressor 6 (line 1) Compressors sizes (line 1) S1 Enable size and size for compressor group 1 (line 1) … S4 … Enable size and size for compressor group 4 (line 1) C01 … C12 Regulation by Measure unit Refrigerant Size group for compressor 1 (line 1) or presence of inverter … Size group for compressor 6 (line 1) Compressor control by temperature or pressure (line 1) Unit of measure (line 1) Type of refrigerant (suction Line 1) … NO --S1 … S1 SAME CAPACITY YES --… NO --S1 … S1 PRESSURE barg R404A Regulation type Compressor control type (line 1) NEUTRAL ZONE YES 100 Ib80 Ib81 Ib82 Ib90 Ib91 Enable integral time action Enable integral time for proportional suction line control (line 2) NO Setpoint Setpoint without compensation (suction line 2) 3.5 barg Differential Differential (suction line 2) 0.3 barg Dedicated pRack board for Suct.line(s) and cond.line(s) on different boards, that is, condenser line(s) on NO condenser line dedicated board Fans number Number of fans (line 1) 3 Modulate speed device Fan modulating speed device (line 1) NONE Ib92 Regulation by Measure unit Refrigerant Fans control by temperature or pressure value (line 1) Unit of measure (line 1) Type of refrigerant (condenser line 1) PRESSURE barg R404A Regulation type Fan control type (line 1) PROPORTIONAL BAND NO 12,0 barg 2,0 barg NO Ib93 Ib94 Ib95 Ib96 Ib1a … Ib1e Enable integral time action Enable integral time for proportional band control Setpoint Setpoint without compensation (condenser line 1) Differential Differential (condenser line 1) Configure another conSecond condenser line configuration densing line Fans number Number of fans (line 2) … … Differential Differential (condenser line 2) Type of Installation Type of plant Ic04 ----- 0 to 16 NONE INVERTER PHASE CONTROL --PRESSURE / TEMPERATURE --… --R22 - R134a - R404A - R407C R410A - R507A - R290 - R600 R600a - R717 -R744 - R728 - R1270 - R417A - R422D -R413A - R422A - R423A - R407A - R427A - R245Fa - R407F - R32 --PROPORTIONAL BAND NEUTRAL ZONE --NO / YES … (**) … (**) … (**) … (**) --NO / YES 3 … 2,0 barg SUCTION + CONDENSER --… … (**) --- Measure Units Unit of measure Number of suction lines Number of suction lines Dedicated pRack board for Suction lines are on different boards suction line Compressors type Type of compressors (line 1) °C/barg 1 NO ------- RECIPROCATING --- Compressors number Compressors type 4 RECIPROCATING ----- 0 1 ----- RECIPROCATING / SCROLL SCREW 1…6/12 (*) RECIPROCATING / SCROLL SCREW 1…6 0…2 4 0 NO ------- 0…16 0…16 NO / YES --NO NO NO --------- --NO / YES NO / YES NO / YES Ic01 Ic02 Ic03 UOM Values --NO / YES % 100; 50/100; 50/75/100; 25/50/75/100; 33/66/100 … … --NO / YES kW S1…S4 --S1…S4/INV … … --S1…S4 --SAME CAPACITY DEFINE SIZES --NO / YES kW 0.0…500.0 … … --NO / YES kW 0.0…500.0 --S1…S4/INV … … --S1…S4 --PRESSURE / TEMPERATURE --… --R22 - R134a - R404A - R407C R410A - R507A - R290 - R600 R600a - R717 -R744 - R728 - R1270 - R417A - R422D -R413A - R422A - R423A - R407A - R427A - R245Fa - R407F - R32 --PROPORTIONAL BAND NEUTRAL ZONE --NO / YES … (**) … (**) … (**) … (**) --NO / YES Ic05 Number of compressors (line 1) Type of compressors (line 2) Ic06 Ic07 Ic08 Ic09 Ic10 (display only) Id01 Id02 Compressors number Number of compressors (line 2) Number of condensing Number of condenser lines in the system lines Line 1 Number of fans (line 1) Line 2 Number of fans (line 2) Dedicated pRack board for Condenser lines are on different boards condenser line Boards necessary pLAN boards required for the selected pre-configuration Save configuration Save Manufacturer configuration Load configuration Manual installation of Manufacturer configuration Restore Carel default Manual installation of Carel default values 0…16 … … (**) SUCTION CONDENSER SUCTION + CONDENSER °C/barg / °F/psig 0…2 NO / YES Tab. 7.a (*) Depending on the type of compressor (**) Depending on the unit of measure selected (***) Depending on the compressor manufacturer, see relative paragraph (****) Depending on the hardware size pRack +0300025EN rel. 1.5 - 17.02.2020 72 ENG 8. ALARMS pRack pR300 can manage both alarms relating to the status of the digital inputs and to operation of the system. For each alarm, the following are controlled: • The actions on the devices, if necessary • The output relays (one global and two with different priorities, if configured) • The red LED on the terminal and the buzzer, where present • The type of acknowledgement (automatic, manual, semiautomatic) • Any activation delay 8.1.3 Log The alarm log can be accessed: • from branch G.a of the main menu • by pressing the (Alarm) button and then (Enter) when there are no active alarms • by pressing (Enter) after having scrolled all the alarms. The alarm log screens show: Order of activation (no. 01 is the oldest alarm) Hour and date the alarm was activated Short description Main values recorded at the moment the alarm was activated (suction pressure and condensing pressure) Note: A maximum of 50 alarms can be logged; after this limit any new events overwrite the oldest ones, which are therefore deleted. 1. 2. 3. 4. The complete list of alarms, with the related information as described above, is available in Appendix A.4. 8.1 Alarm management All alarms feature the following behaviour: • When an alarm is activated, the red LED flashes and the buzzer is activated (where present); the output relays corresponding to the global alarm and to any alarms with priority are activated (if configured) 8.2 Compressor alarms • Pressing the (Alarm) button, the red LED stays on steady, the buzzer is muted and the alarm screen is shown • If there is more than one active alarm, these can be scrolled using (Up) (Down). This condition is signalled by an arrow at the bottom right of the screen The number of alarms for each compressor can be set during the configuration phase using the Wizard or subsequently from branch C.a.e/C.b.e of the main menu. The number of alarms is the same for all the compressors on the same line. • Pressing the 8.2.1 (Alarm) button again for at least 3 seconds acknowledges the alarms manually, and these are cleared from the display unless others are active (they are saved in the log) 8.1.1 Priority For certain alarms, the alarm output relay can be set with two types of priority: • R1: serious alarm • R2: normal alarm Note: The maximum number of alarms that can be configured for each compressor depends not only on the type of compressor, but also on the size of pRack and the number of compressors fitted. The corresponding relays, once configured, are activated when an alarm with the corresponding priority occurs. For the other alarms, the priority is fixed and is associated by default with one of the two relays. 8.1.2 Compressor alarms each line After having selected the number of alarms (maximum 4 for the reciprocating or scroll compressors and 7 for screw compressors), the settings can be configured for each alarm, choosing a description from the options shown in the table, the output relay, the type of reset, delay and priority. The effect of the alarm on the devices is set and involves stopping the compressor, except for the oil warning. Acknowledgement The alarms can acknowledgement: have manual, automatic or semiautomatic • Manual: the alarm is acknowledged by pressing the (Alarm) button twice, the first time displays the corresponding alarm screen and mutes the buzzer, the second (extended, for at least 3 seconds) cancels the alarm (which is saved in the log). If the alarm is still active, acknowledgement has no effect and the signal is shown again. • Automatic: when the alarm condition ceases, the alarm is automatically reset, the LED comes on steady and the corresponding screen remains Possible descriptions for compressor alarms Reciprocating or scroll Generic Overload High pressure Low pressure Oil displayed until the (Alarm) button is pressed and held; the alarm is saved in the log. • Semiautomatic: acknowledgement is automatic, until a maximum number of activations in set time. If the number reaches the maximum set, acknowledgement becomes manual. Screw Generic Overload High pressure Low pressure Oil Screw rotation Oil warning (Filter Blocked) Tab. 8.a An example of a screen for selecting the description of the alarm is shown in the figure: For manual acknowledgement, the functions associated with the alarm are not reactivated until acknowledgement has been completed, while for automatic acknowledgement they’re reactivated as soon as the alarm condition ceases. 73 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG After having selected the ‘generic’ description, no other description can be selected. In general, the descriptions are divided into four groups: • generic • others (overload, oil, high pressure , low pressure) • screw rotation • oil warning 8.2.2 After a description has been selected for a certain group, descriptions from a different group can not be selected for that alarm. For example, generic only, or overload + oil, or rotation only or overload + high pressure., etc. can be selected. Each alarm will have one alarm screen, which will show all the descriptions associated to that alarm. Based on the number of alarms selected, the descriptions associated by default are shown in the table below. Default descriptions based on the number of alarms Number of alarms Descriptions 1 Generic Overload HP-LP Overload HP-LP Oil Overload HP LP Oil Overload HP LP Oil Oil warning Overload HP LP Oil Oil warning Rotation Overload HP LP Oil Oil warning Rotation Generic 2 3 4 5 6 7 Low superheat alarm The parameters corresponding to these alarms can be set in branchC.a.e.C.b.e branch of the main menu. For this type of alarm, if enabled, you can choose whether to set a warning and an alarm or just an alarm. If enabled, it is possible to set the absolute (absolute) threshold and the activation. You can also set the delay after which the alarm is entered. When a warning and alarm is selected, if the measured overheating falls below the set threshold, the warning is signaled for the signaling purpose only, and after the delay has been set, the alarm is triggered. If the special option is enabled, the low overheating alarm has the capability to turn off all compressors without the timing, so when all the compressors of the affected line are switched on immediately when the alarm is activated. This alarm features manual or automatic reset, as configured by the user. 8.3 Pressure and prevent alarms pRack pR300 can manage pressure alarms from a pressure switch or probe, according to the following diagram. Alarms from pressure switch: • Low suction pressure • High condensing pressure Alarms from probe: • Low suction pressure • High suction pressure • Low condensing pressure • High condensing pressure One possible example for the low pressure alarms is shown in the figure: LP Differential Pressostat alarm Pressure Probe alarm Fig. 8.a In addition, the high pressure alarm features a prevent function, available by manually overriding the devices as well as using additional functions, such as heat recovery and ChillBooster. Operation of the alarms and prevent function is described below. Tab. 8.b Note: for oil alarms, special management is available whereby the alarm is interpreted as an oil level alarm. When the alarm is activated, a number of attempts are made to restore the level for a set time before the alarm is signalled and the compressor stopped; see paragraph 6.6.1 for details. 8.3.1 Pressure alarms from pressure switch The parameters corresponding to these alarms can be set in branch G.c.a/ G.c.b of the main menu. If a modulating device is used for the compressors, further alarms become available: • compressor inverter warning, common for the entire suction line, when the device is an inverter • oil sump temperature alarm, high discharge temperature and oil dilution, for Digital Scroll™ compressors Low suction pressure from pressure switch The low suction pressure alarm from pressure switch has the effect of stopping all the compressors without observing the various times, therefore when the digital input configured as low pressure switch is activated, all the compressors on the line affected are stopped immediately. For each compressor, two alarm variables are sent to the supervisor, one for each priority. As well as the alarm signal, the description of the alarm is also sent to the supervisor, using the values shown in the table: This alarm features semiautomatic reset, and both the monitoring time and the number of activations in the specified period can be set. If the number of activations is higher, reset becomes manual. In addition, the delay after which the alarm is activated on both start-up and during operation can be set. The delay at start-up only applies to unit start-up and not compressor power-up. The supervisor can interpret the variables sent by pRack pR300 and provide the correct description of the alarm. High condensing pressure from pressure switch The high condensing pressure alarm from pressure switch has the effect of stopping all the compressors without observing the various times and forcing the fans on at maximum speed, therefore when the digital input configured as high pressure switch is activated, all the compressors on the line affected are stopped immediately and the fans operate at maximum output. This alarm features manual or automatic reset, as configured by the user. The delay after which the alarm is activated can also be set pRack +0300025EN rel. 1.5 - 17.02.2020 74 ENG 8.3.2 Prevent by activating heat recovery The parameters corresponding to this function can be set in branch G.b.a/ G.b.b of the main menu, if the heat recovery function is present. Pressure alarms from probe The parameters corresponding to these alarms can be set in branch C.a.e/ C.b.e of the main menu for the suction pressure and D.a.e/D.b.e for the condensing pressure. As well as enabling the function, an offset from the activation threshold for the prevent by overriding devices function must be set. The activation differential for this function is the same as set for the prevent by overriding devices function. For these types of alarms, reset is automatic and the activation threshold and differential can be set, as well as the type of threshold, which may be absolute or relative to the control set point. The figure shows an example of setting the threshold to relative. When reaching the threshold, pRack pR300 activates the heat recovery function, if the conditions allow; see paragraph 6.6.3 for details. HP Prevent by activating ChillBooster The parameters relating to this function can be set in branch G.b.a/G.b.b of the main menu, if the ChillBooster function is present. Pressure Differential Relative threshold Setpoint As well as enabling the function, an offset from the activation threshold for the prevent by overriding devices function must be set. The activation differential for this function is the same as set for the prevent by overriding devices function. Alarm Fig. 8.b Note: for temperature control, the alarms from probe are managed based on temperature even when pressure probes are fitted. When reaching the threshold, pRack pR300 force activates the ChillBooster, if the conditions allow; see paragraph 6.6.5 for details. The effects of the different pressure alarms from probe are described below. The following figure illustrates the activation thresholds for the prevent function and the safety devices: Low suction pressure from probe The low suction pressure alarm from probe has the effect of stopping all the compressors, ignoring the times. Pressure HP by pressostat High suction pressure from probe The high suction pressure alarm from probe has the effect of forcing all the compressors on, ignoring the control times, but observing the compressor protection times. HP by probe Low condensing pressure from probe The low condensing pressure alarm from probe has the effect of stopping all the fans, ignoring the times. Prevent Offset Heat reclaim or ChillBooster High condensing pressure from probe The high condensing pressure alarm from probe has the effect of forcing all the fans on and stopping all the compressors, ignoring the times. time Fig. 8.c 8.3.3 High pressure prevention 8.3.4 pRack pR300 can manage 3 types of high condensing pressure prevention actions, involving: • overriding the compressors and fans • activating heat recovery • activating ChillBooster Prevent low suction pressure pR300 offers the possibility to reduce compressor capacity in the event of low suction pressure. The parameters relating to this function can be set in branch G.b.a/G.b.b of the main menu. The effect of this function is to operate the compressors at a set percentage of capacity as soon as pressure falls below the prevent set point and related differential (screen Gab06) In addition to the activation threshold, which is always absolute, and the activation differential, a compressor deactivation time can be set, corresponding to the time needed to switch off all the compressors except for the minimum capacity step. The evaluation time and number of activations allowed in a certain time period can also be set. If the number of activations exceeds the setting, manual reset is required (screen Gab07) When the prevent function is activated, an alarm icon is shown on the main screen, and a warning screen appears in the alarms. Prevent by overriding the compressors and fans The parameters relating to this function can be set in branch G.b.a/G.b.b of the main menu. The effect of this type of prevent action is to force all the fans on at maximum and switch all the compressors off, except for the minimum capacity stage, ignoring the control times but observing the compressor protection times. The minimum capacity stage means one compressor in the case of compressors without capacity control and modulation devices, or the minimum capacity stage for capacity-controlled compressors (e.g. 25%), or alternatively the minimum output of the modulation device in the case of inverters, Digital ScrollTM compressors or screw compressors with continuous modulation. Prevent low suction pressure with auxiliary control Advanced configurations are available when using auxiliary control, so as to ensure a better response when activated. As well as the activation threshold, which is always absolute, and the activation differential, a compressor deactivation time can be set, corresponding to the time needed to switch off all the compressors, except for the minimum capacity stage. If the suction pressure falls below the set threshold (screen Gba08), compressor capacity is reduced proportionally to the limit set point. Normally, when the prevent function ends, the current capacity is instantly brought to the level needed to meet the control request. If the parameter “Align request after prevent” is enabled (screen Gba09), the current request is aligned with the limit value. In addition, both the monitoring time and the number of activations in the specified period can be set. If the number of activations is higher, reset becomes manual. 75 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG 9. SUPERVISORY AND COMMISSIONING SYSTEMS pRack pR300 can be connected to various supervisory systems, specifically the Carel and Modbus communication protocols can be used. For the Carel protocol, the PlantVisor PRO and PlantWatch PRO models are available. 9.2 Commissioning software pRack Manager is configuration and real-time monitoring software used to check the operation of pRack pR300, for commissioning, debug and maintenance operations. In addition, pRack pR300 can be connected to the pRack Manager commissioning software. The software is available on the internet at http://ksa.CAREL.com in the section “download à support à software utilities”.The installation includes, in addition to the program, the user manual and the necessary drivers. 9.1 PlantVisor PRO, PlantWatch PRO, Boss and Boss-mini supervisory systems pRack Manager can be used to set the configuration parameters, modify the values of volatile and permanent variables, save graphs of the main system values to file, manually manage the unit I/Os using simulation files and monitor/reset alarms on the unit where the device is installed. Connection to Carel PlantVisor PRO and PlantWatch PRO supervisor systems uses the RS485 card already fitted on some models of pRack pR300. For details on the models of card available, see Chapter 1. pRack pR300 is able to virtualise all the inputs and outputs, both digital and analogue, therefore each input and output can be overridden by pRack Manager. Note: In general, the pRack boards that manage the suction lines must be fitted with the supervisor connection card, consequently boards with pLAN address 1 or 2. It is also possible to use the CAREL protocoll to both BMS ports (J25 biul-it and optional) of eacn board. If a port is used with CAREL protocoll, it is necessary to set the other with sarà MODBUS protocoll. pRack Manager manages <file name>.DEV files that contain the user parameter configurations and that can be downloaded from the pRack pR300 board and then subsequently uploaded. To use the pRack Manager program, a serial converter output RS485 with CVSTDUTLF0 (telephone connector) or CVSTDUMOR0 (3 pin terminal) must be connected to the board. The connection to pRack Manager can be made: 1. Via the RS485 serial port used for the “pLAN” connection 2. Via the BMS serial port with RS485 serial card and activating the pRack Manager protocol by parameter on screen Fca01 or connecting pRack Manager and selecting SearchDevice = Auto (BMS or FB) on the “Connection settings” tab. In this case, the connection is established after around 15-20 seconds. Three different models of PlantVisor PRO and PlantWatch PRO are available, used to supervise system configurations with one or two lines: • L1 – one line: can be used for system configurations with just one suction and/or condenser line. • L2 – one line: can be used for system configurations with two suction and/or condenser lines, and the two suction lines are managed by separate boards. • Two lines: can be used for system configurations with two suction and/ or condenser lines, and the two suction lines are managed by the same board. Important: the BMS serial port should only be used for monitoring the variables, while to update the software use the RS485 serial port dedicated to the pLAN connection. Important: model L2 – One line must be used only in association with model L1 – One line. For supervision of system configurations with just one line only model L1 – One line can be used. The following figure shows an example of connection to the PC via the RS485 serial port used for the “pLAN” connection Tutorial: the rule applied for using the models is summarised below: • cconfiguration with board with pLAN address 2 à separate models • configuration without board with pLAN address 2 à one model only 4 J25 BMS2 3 2 C8 C7 J14 J10 CVSTDUTLF0 NC8 C7 J13 NO8 C4 NO7 J15 1 C8 2 NC8 C7 ID8 C7 NO8 ID7 C4 NO7 C4 NO6 C1 NO5 NO4 C1 NO3 J25 BMS2 3 J15 1 J26 FBus2 IDC1 ID8 ID7 ID6 ID5 ID4 ID3 ID2 ID1 Y4 Y3 J5 Y2 Y1 VG0 VG GND U5 GND U4 +VDC 4 B M S card J4 J3 GND U3 U2 J2 U1 +5 VREF G0 GND G +Vterm J24 J14 J13 J10 FieldBus card J1 J12 J11 pLAN pR300 NO2 J26 FBus2 NO1 C4 NO6 NO5 C1 J12 J11 pLAN NO4 C1 NO3 NO2 NO1 A connection example for using PlantVisor PRO and PlantWatch PRO is shown in the figure. pR300 B M S card IDC1 ID6 ID5 ID4 ID3 ID2 ID1 Y4 Y3 J5 Y2 VG0 VG GND U5 GND U4 +VDC Y1 J4 J3 GND U3 U2 J2 U1 G0 GND G +Vterm J24 +5 VREF FieldBus card J1 CVSTDUMOR0 Power supply Fig. 9.a Fig. 9.b The complete list of supervisor variables, with the corresponding addresses and descriptions, can be supplied upon request. pRack +0300025EN rel. 1.5 - 17.02.2020 Note: for further details see the pRack Manager program online help. 76 ENG 10. UPDATING THE SOFTWARE The pRack pR300 boards are supplied with the software already loaded. If an update is required, the following can be used: • pRack Manager • SmartKey programming key 10.3 Pendrive: operating instructions 10.3.1 File extensions, names and contents Various types of files can be uploaded and downloaded and are distinguished by their extension. Note: The pRack pR300 software is protected by digital signature and cannot be loaded onto hardware other than pRack pR300 (e.g. pCO3), otherwise after 5 minutes of operation the software locks up, all the relays open and the warning “INVALID OEM IDENTIFIER” is shown’. File names In order to be recognised, the names of the directories and files on the pendrive must have no more than 8 characters; the controller makes no distinction between upper-case and lower-case characters. However, during DOWNLOAD the names of the directories created by the controller on the pendrive are always in upper-case. The update files are available at http://ksa.CAREL.com. Important: each version of the pRack pR300 software is associated with a specific controller firmware version (BIOS), therefore if updating the version, always check and where necessary update the BIOS on the board. The appropriate BIOS version is supplied together with the pRack pR300 update files. FILE TYPES FOR UPLOAD File extension Description .IUP Contains the definitions of the screens on the terminal .BLB Contains the application .BIN Contains the application (with pLAN table) .BLX Contains the Logique of atoms custom in C language .GRP Contains the graphics .DEV Contains the preset configuration parameter values PVT,.LCT Contains the descriptions of the public variables to be logged. Generated by 1Tool, this is used by the LogEditor module and must be loaded together with the.LCT file 10.1 Update via pRack Manager /RHEC Manager The software resident in the pRack pR300 boards can be updated from a PC. Downloaded files are saved in directories created automatically, with the following name format: NAMXY_WZ Where: NAM: identifies the type of data downloaded (LOG for logs, BKP for the application, DEV for the buffer memory, CPY for all the data from the controller). XY: progressive number from 0 to 99 WZ: controller pLAN address. For the connection procedure see Chapter 9, while for further details see the pRack Manager program online help.. Note: The pCOLoad program can also be used to update the pRack pR300 software, however Winload cannot be used. 10.2 Updating using SmartKey The SMARTKEY programming key can copy the contents of one pRack pR300 board to another identical board, using the telephone connector on the terminal (the pLAN must be disconnected). Example: a directory named LOG00_01 contains the log files (LOG) downloaded from a device whose pLAN address is 1. Since the key contained no directory of this type before download, it is indicated with 00. From a PC, with the SmartKey Programmer software running, the key can be configured to perform specific operations: acquire log files, program applications, etc. The SmartKey Programmer software is installed together with pRack Manager. Important: No more than 100 files of the same type can be downloaded to the pendrive, as the directories created can only be numbered with XY=00 to 99. The following figure shows the connection of the SmartKey to the PC using the PCOSO0AKY0 converter. FILE TYPES FOR DOWNLOAD (controller pLAN address = 1) File extension Directory name Description .DWL LOG00_01 Logged data .DWL,.DEV,.LCT,.PVT BKP00_01 Application .DEV DEV00_01 Non-volatile parameters .DWL,.DEV,.LCT,.PVT CPY00_01 All data on the controller Tab. 10.c The downloaded files to have fixed names. In particular, the application file is called “ppl–pRack.dwl”, the BIOS file “bios–pRack.bin”, the files containing the logs and related information are “logs.dwl”, “logs.lot” and “logs.pvt”, respectively. Finally, the buffer memory is saved to the file on the pendrive. Menu access The following are the steps for accessing the pendrive management menu. Procedure: 1. Connect the pendrive to the master port. mode start PCOS00AKY0 Fig. 10.a Note: for further details on using the SmartKey, see the corresponding instruction sheet. For details on the SmartKey Programmer see the online manual. USB key B M S c a rd Fig. 10.b 77 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG 2. To show a string on the display describing the operation being performed, add the “[NAM]” instruction, followed by the string to display. The following file will display the string: Press Alarm and Enter together for 3 seconds to enter the option menu. Select FLASH/USB memory and press Enter to confirm. “UPL CHILLER.DEV” [FUNCTION] Upload non volatile memory 4:45&.*/'03."5*0/ -0(%"5" 05)&3*/'03."5*0/ '-"4)64#.&.03: [DIR] CHILLER Fig. 10.c 3. [NAM] UPL CHILLER.DEV Select USB pen drive and press Enter to confirm. CHILLER.DEV /"/%'-"4)'*-&4 64#1&/%3*7& 3. To select only some of the files in the same directory, list them after a label. The following labels are allowed and must be entered in the order shown in the table: Fig. 10.d UPLOAD file labels No. Label File type 1 [BIO] (*) 2 [IUP] 3 [BIN] 4 [DEV] 5 [GRP] (*) BIO = BIOS file Important: Wait a few seconds after the pendrive has been plugged in for it to be recognised by the controller. If the message “No USB disk or PC connected” is displayed momentarily with the request to connect a pendrive key or computer USB cable, wait a few seconds until the recognition message is shown (“USB disk found”) and the following screen appears. 4. file.bin file.iup file.bin, blb file.dev file.grp No. Label File type 6 7 8 9 [PVT] [LCT] [OED] [SGN] file.pvt file.lct file.oed file.sgn Select UPLOAD. Notes: • to get the.bin file from the BIOS in the format available on http://ksa. carel.com (.os file), unzip the.os file; 4ELECTFUNCTION 61-0"% PENP$0 %08/-0"% P$0PEN • the [IUP] label can be followed by one or more “.iup” files. Important: • the order in which the file names are entered is fundamental and must Fig. 10.e not be changed; • do not enter empty lines or spaces in the file (e.g. at the end of a line); • each file after the last line of code must contain a “carriage return” 10.3.2 Upload An application plus BIOS or buffer memory (parameters) can be uploaded from the pendrive. The following modes are available: automatic, autorun and manual. Automatic and autorun modes require using configuration files. character (CR¿ ), as shown in the following example. Example: The following file will upload the BIOS and an application. Configuration file structure Configuration files must start with the string “[FUNCTION]” followed by a string that identifies the function, as shown in the table. Function UPLOAD an application or a BIOS file plus an applic. UPLOAD non-volatile memory (.dev) UPLOAD the entire contents of the pRack [FUNCTION]¿ Upload application¿ ¿ [DIR] ¿ NEW AHU ¿ ¿ [NAM] ¿ BIOS+APPL+LOGSv58B36 ¿ ¿ bisn509.bin ¿ ¿ [IUP] ¿ AHU_EN.iup ¿ AHU_IT.iup ¿ ¿ [BIN] ¿ AHU.blb ¿ ¿ [DEV] ¿ AHU.dev ¿ ¿ [GRP] ¿ AHU.grp ¿ ¿ [PVT] ¿ AHU.pvt ¿ ¿ [LCT] ¿ AHU.lct ¿ String Upload application Upload non volatile memory Copy pRack upload After the description of the desired function, various options are available: 1. To copy the complete contents of the directory, simply write the name of the directory (e.g. the entire contents of the CHILLER directory): [FUNCTION] Upload non volatile memory [DIR] CHILLER 2. To copy just 1 file in a directory, enter the file’s name (e.g. the CHILLER. DEV file in the CHILLER directory). [FUNCTION] Upload non volatile memory [DIR] CHILLER CHILLER.DEV pRack +0300025EN rel. 1.5 - 17.02.2020 78 ENG 4. 10.3.3 Automatic upload To automatically upload the parameter memory using the first configuration file shown in the preceding paragraph, access the system menu as previously described and proceed as follows: 1. The display flashes to indicate that after loading the new BIOS the controller is being reset. '8WBMJEBUJPO 1MFBTFXBJU Select automatic mode. A screen is shown describing the function of the buttons. Press Enter to confirm. 4ELECTUPLOADMODE "650."5*$.0%& ."/6"-.0%& Fig. 10.l pGD NO LINK Fig. 10.f 2. Confirm by selecting Prg. A screen is displayed requesting confirmation to upload the non-volatile memory. Press Enter to confirm. Fig. 10.m ••• 61-'*-&?%&7 5. The test phase starts. "PPLICATIONPROGRAM CORRUPTEDORNOT PRESENT 8"*5*/(FORUPGRADE Fig. 10.g 3. At the end a message will ask the user to remove the pendrive. Fig. 10.n ••• •61-0"%*/('*-& 1-&"4&8"*5 pGD /0-*/, Fig. 10.h 10.3.4 Upload in autorun mode Uploading in autorun mode is a special case of uploading in automatic mode. Unlike automatic mode, the user must wait for a specific message to appear on the display to start or disable the operation described in the configuration file. To upload a file in autorun mode, a configuration file must be created and named “autorun.txt”. Fig. 10.o 6. The controller warns that no application has been loaded. "PPLICATIONPROGRAM CORRUPTEDORNOT PRESENT 8"*5*/(FORUPGRADE Example of uploading BIOS+application The upload involves two steps: first the BIOS is updated and then the application. The information is shown on the pRack’s built-in display and on the pGDE terminal, when both are featured. Fig. 10.p Procedure: 1. Connect the pendrive to port A. pGD /0-*/, USB key BMS card 7. Fig. 10.q The application update then starts. Fig. 10.i 2. After a few seconds, Autorun mode starts. Press Enter to confirm. 6PLOADAPPL •1LEASEWAIT • "65036/.0%& 61-0"%"11-*"5*0/ 1RESS&/5&3TOSTART &4$TOEXITAUTORUN Fig. 10.r 3. Fig. 10.j The validity of the FW is checked and the BIOS is loaded. pGD /0-*/, '8VALIDATION 1LEASEWAIT Fig. 10.s Fig. 10.k 79 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG 8. Remove the pendrive. The update is complete. Wait for the display to stop flashing, indicating that the controller is being reset before restarting. 2. Download completed. 0PERATIONCOMPLETE %ATADOWNLOADED TO#,1? • 6QMPBEDPNQMFUF 3FNPWF64#LFZ BOEXBJUSFTFU Fig. 10.w Example: On the controller with address 1, the autorun file will create a directory called BKP00_01 and copy the files APPL_PRack.DWL and FILE_ DEV.DEV to this directory. Fig. 10.t pGD Connecting to a computer Connect the slave USB port on the controller to the USB port on the computer where pRack Manager is installed. /0-*/, Fig. 10.u Important: As can be seen, when updating the BIOS and the application, the pGDE terminal shows the message “NO LINK”, meaning that no connection is established. Do not remove the terminal and wait for the end of the update procedure, when the pGDE terminal replicates the messages on the built-in display. Note: Autorun run is especially useful in those cases in which the same operation needs to be performed on several controllers. For example, to load different applications on controllers connected in a pLAN network, only one autorun file needs to be created; this uploads the various directories contained on the pendrive based on the address of the controllers. The controller with address XY will only load the directory called “nomedir_XY” [“DirName_XY”]. The pendrive then only needs to be plugged into each controller to run the upload, confirming from the shared terminal. Fig. 10.x Important: • do not install any type of converter between the computer and port B, even if requested by the program’s guided procedure; • pRack Manager manages compressed files (.GRT/.OS). Once the connection is established, the following operations are available: UPLOADING the application or BIOS+application. DOWNLOADING the non-volatile memory. Commissioning Managing the NAND flash memory. Once the USB cable is removed, the port will become available again after approximately 5 s. 1. 2. 3. 4. 10.3.5 Manual upload To manually upload the contents of the pendrive the user must access the management menu from the system screens, selecting UPLOAD and then MANUAL. The files are selected by pressing ENTER when the cursor is on the desired file name. A selected file is marked by the symbol “*” on the left. Once the files have been selected (all in the same directory), press PRG to start the upload. To display the contents of a directory press ENTER. To go up one directory level press ESC. Once the upload has started, the messages shown on the screen are the same as in automatic and autorun mode. Important: If no connection is established with pRack Manager after plugging in the USB cable, wait at least 1 minute before using the USB ports again after removing the cable. 10.4 Configuring pCOWeb/pCOnet from a system screen 10.3.6 Download As mentioned above, the DOWNLOAD operation can be managed in two ways: 1. Manual mode: follow the steps described in the paragraph “Automatic upload” and select manual operation. Then each file must be selected and downloaded. 2. Autorun mode: prepare a file called “autorun.txt”, containing a string that identifies the function to be performed. See par. 6.6 for information on how to access the BIOS system menu. Starting from: • BIOS release 5.16 BIOS, and from • pCOWeb firmware version A1.5.0, and from • pCOnet firmware version A485_A1.2.1 pCOWeb and pCOnet communication parameters can be configured. The purpose is to configure the network (Ethernet for pCOWeb, RS485 for pCOnet) when the respective card is installed for the first time. The remaining parameters (alarms, events, etc.) can be configured using the usual tools, i.e. BACset or web interface (pCOWeb only). Configuration can be done either when using the Modbus protocol or the CAREL protocol, but only on the BMS1 serial port. The screens for configuring pCOWeb and pCOnet can be opened by accessing the system screens and selecting OTHER INFORMATION and then PCOWEB/NET Konfig. Then, select “PCOWEB settings” to configure pCOWeb parameters or “PCONET settings” to configure pCOnet parameters. Function String DOWNLOAD the application Download application DOWNLOAD non-volatile memory Download non volatile memory (.dev) DOWNLOAD the entire contents of the pRack Copy pRack download The result is the creation of files with the required extensions, which will be placed in the respective directories as described in the paragraph “File names”. When the operation is completed, the display shows a message with the name of the directory created. [FUNCTION] Download application The following screen will be displayed. 1. Press Enter to confirm. Configuring pCOWeb When you select “PCOWEB settings” the following screen will appear: '8VALIDATION 1LEASEWAIT D H C P : I P Fig. 10.v pRack +0300025EN rel. 1.5 - 17.02.2020 USB connector from computer BMS card 80 - - - A D D R E S S - - - . - - - . - - - . - - - ENG After a short time the fields are populated with the current parameters. If the fields are not populated with the current parameters, check the firmware version of pCOWeb and the protocol used by the BMS serial port. The parameters can now be edited by selecting the respective fields using the ENTER button and setting the desired values using the UP/DOWN buttons. If the DHCP option is set to ON, the IP address and Netmask fields cannot be changed. Pressing ENTER repeatedly will display all the parameters available, as listed in the following screens: N e G a t m a - - t e w - - - D N S D N S - 1 1 - : : - s k . a y . - : : - . - . - B A C n e t B A C n e t - . - - - . - - - - . - - - . - - - - - . - - - . - - - - - . - - - . - - - : - p e - - : - - - - - - - I D T y - 10.5 Saving parameters between different software versions The configuration parameters can be saved and loaded after having updated the software. The update requires the files relating to the new version being loaded (files with the following extensions: .iup, .blx., .blb, .grt, .dev) and the connection files (files with the following extensions: .2cf, .2ct, .2cd) for the installed version and the new version. The connection files must be copied to the ‘’2cf’’ directory under pRack Manager, for example C:\Program Files\CAREL\pRackManager\2cf. The update procedure including saving the parameters is as follows (for details on the functions of the pRack Manager software see the online manual): 1. Switch the unit off from the user terminal or supervisor or digital input 2. Connect the PC where pRack Manager is installed using the pLAN serial (disconnect the terminal if necessary) and disconnect any BMS connections 3. Start the pRack Manager software 4. In the ‘’Connection settings’’ panel, set Baud rate to ‘’Auto’’ and SearchDevice to ‘’Auto (pLAN)’’ and select the COM port under PortNumber (if necessary, use the Wizard to detect the correct COM) 5. In Commissioning/Settings select the .2cf file relating to the version on pRack pR300, e.g. 1.0 6. Power down pRack pR300, power up again and wait for the controller to come “On line” 7. In Device Configuration read all the variables and save them to an .txt file (required) 8. Update the software version on pRack pR300, selecting from pRack Load the following update files and selecting ‘’Update graphic resources and ‘’Enable zipped upload’’: • .iup (maximum 2 files) • .blx • .blb • ClearAllx.dev, where x is the pLAN address of the board being updated 9. Wait for the update procedure to end. 10. Power down, disconnect the PC and if necessary reconnect the terminal 11. Power up again and run a quick start-up procedure (pre-configurations or Wizard, confirming the default parameters) 12. Power down 13. Reconnect pRack Manager and power up again 14. In Commissioning/Settings select the .2cf file relating to the new version now loaded on pRack 15. From Device Configuration, import the previously saved .txt file and write all the variables 16. Power down, disconnect the PC and reconnect the terminal if necessary 17. Power up again Once the parameters have been chosen they can be updated by going to the following screen and pressing ENTER. P C O W E B U p d a t e C O N F I G E N A B L E p C O W e b ? N O While the parameters are being updated, the following message is displayed: P C O W E B P l e a s e e n d o f C O N F w a i t u p d a I G E N A B L E f o r t e At the end, the screen shows: P U R a C p e p O W E B d a t e b o o t p l y n C O N F c o m p p C O W s e w I G E N A B L E l e t e e b t o e t t i n g Configuring pCOnet When you select “PCONET settings” the following screen will appear: B A C n e B A C n e t t - I D b a - - : - u d - - : - - - - - At the end of the procedure, pRack pR300 will be programmed with the updated software and the previously configured parameters. - Important: if using the BMS serial port to read/write variables, pRack pR300 continues operating, and therefore software malfunctions may occur. Consequently, use the RS485 serial port provided for the pLAN connection when carrying out the software update operations described above. After a short time the fields are populated with the current parameters. The parameters can now be edited by selecting the respective fields using the ENTER button and setting the desired values using the UP/DOWN buttons. Pressing ENTER repeatedly will display all the parameters available, as listed in the following screen: B A C n e t M A C : M a x M a s t e r s M a x F r a m e s : : - - - - Note: to update the software without maintaining the parameter configuration, simply complete steps 1 to 4 and 8 to 10 in the previous procedure. In this case, the unit will need to be reconfigured using the complete start-up procedure. - Once the parameters have been chosen they can be updated following the procedure described for configuring pCOWeb. 81 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG 11. APPENDIX A.1 System configurations available The system configurations available are shown in the table: System configurations: Config. Description number Suction lines Condenser lines 1 2 3 4 5 6 No suction line, one condenser line No suction line, two condenser lines 1 suction line (scroll or piston compressors), no condenser line 1 suction line (scroll or piston compressors), 1 condenser line 1 suction line (scroll or piston compressors), 1 condenser line on a separate board 2 suction lines on the same board (scroll or piston compressors), no condenser line 0 0 1 1 1 2 1 2 0 1 1 0 7 2 suction lines on the same board (scroll or piston compressors), 1 condenser line 2 1 8 2 suction lines on the same board (scroll or piston compressors), 1 condenser line on a separate board 2 suction lines (scroll or piston compressors), 2 condenser lines on the same board 2 1 2 2 2 suction lines on the same board (scroll or piston compressors), 2 condenser lines on separate boards 2 suction lines on separate boards (scroll or piston compressors), 1 condenser line on suction line 1 board 2 suction lines on separate boards (scroll or piston compressors), 1 condenser line on a separate board 2 suction lines on separate boards (scroll or piston compressors), 2 condenser lines (one for each suction line board) 2 suction lines on separate boards (scroll or piston compressors), 2 condenser lines on separate boards 1 suction line (up to 2 screw compressors), no condenser line 1 suction line (up to 2 screw compressors), 1 condenser line 1 suction line (up to 2 screw compressors), 1 condenser line on a separate board 2 suction lines on separate boards (up to 2 screw compressors on line 1 and scroll or piston compressors on line 2), 1 condenser line on suction line 1 board 2 suction lines on separate boards (up to 2 screw compressors on line 1 and scroll or piston compressors on line 2), 1 condenser line on a separate board 2 suction lines on separate boards (up to 2 screw compressors on line 1 and scroll or piston compressors on line 2), 2 condenser lines (one for each suction line board) 2 suction lines on separate boards (up to 2 screw compressors on line 1 and scroll or piston compressors on line 2), 2 condenser lines on separate boards 2 suction lines on separate boards (scroll or piston compressors), 2 condenser lines (line 1 on separate board, line 2 on board in common with suction) 2 2 2 1 2 1 2 2 2 2 1 1 1 2 0 1 1 1 2 1 2 2 2 2 2 2 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Compressors Max. number of Units present in L1/L2 compressors per pLAN (in add. to line L1/L2 the terminal) 1 1 scroll, piston 12 1 scroll, piston 12 1 scroll, piston 12 1, 3 scroll, piston/ 12/12 1 scroll, piston scroll, piston/ 12/12 1 scroll, piston scroll, piston/ 12/12 1, 3 scroll, piston scroll, piston/ 12/12 1 scroll, piston scroll, piston/ 12/12 1, 3 scroll, piston scroll, piston/ 12/12 1, 2 scroll, piston scroll, piston/ 12/12 1, 2 ,3 scroll, piston scroll, piston/ 12/12 1, 2 scroll, piston scroll, piston/ 12/12 1, 2, 3, 4 scroll, piston screw 2 1 screw 2 1 screw 2 1, 3 screw/scroll, 2/12 1, 2 piston screw/scroll, 2/12 1, 2, 3 piston screw/scroll, 2/12 1, 2 piston screw/scroll, 2/12 1, 2, 3, 4 piston scroll, piston/ 2/12 1, 2, 3, 4 scroll, piston Reference diagram a a a a b c c e f g h d h i a a b h d h i l Tab. A.a The system configurations available refer to the following diagrams: b. 1 suction line (scroll or piston compressors) and 1 condenser line on a separate board: a. up to 1 suction line (scroll or piston compressors) and up to 1 condenser line on just one pRack pR300 board: 3 2 C8 C7 J14 C8 C7 NC8 ID7 ID8 IDC1 NO8 C8 NC8 ID7 ID8 ID6 ID5 ID4 C4 ID3 Y4 Y3 Y2 ID2 Y1 C4 ID1 VG0 C1 NO6 VG NO3 GND U5 J5 NO2 GND U4 +VDC GND U3 U2 U1 G0 G GND +Vterm B M S ca rd J4 J3 IDC1 I/O J12 J11 pLAN J13 J14 J10 4 J25 BMS2 C7 C7 NO7 NO4 C1 pLAN NO1 ID8 ID7 ID6 ID5 ID4 ID3 Y4 Y3 Y2 ID2 J5 ID1 VG0 VG GND Y1 J4 U5 GND U4 +VDC J2 B M S c ard J3 GND U3 U2 U1 G0 +5 VREF G +Vterm GND J2 J24 +5 VREF FieldBus card J24 C7 pR300 pR300 J1 1 J15 J1 FieldBus card 2 1 J26 FBus2 NO5 4 3 J26 FBus2 NC8 C7 C4 J13 J25 BMS2 NO8 NO7 C4 C1 NO6 NO5 NO4 C1 NO3 NO2 NO1 J12 J11 pLAN NO8 C4 4 J25 BMS2 J15 J14 J13 J10 J10 NO7 C4 NO6 NO5 C1 J12 J11 pLAN NO4 C1 NO3 NO2 NO1 I/O I/O 3 2 J15 1 J26 FBus2 pR300 B M S ca r d I/O Fig. A.b pRack +0300025EN rel. 1.5 - 17.02.2020 82 IDC1 ID6 ID5 ID4 ID3 ID2 Y4 Y3 J5 ID1 VG0 VG GND U5 GND U4 +VDC Y1 J4 J3 GND U3 U2 J2 U1 +5 VREF G0 G J24 GND +Vterm FieldBus card J1 Y2 Fig. A.a ENG c. 2 suction lines on the same board (scroll or piston compressors) and f. up to 1 condenser line: 2 suction lines (scroll or piston compressors), 2 condenser lines on the same board: I/O I/O I/O pR300 pR300 I/O I/O I/O I/O Fig. A.c Fig. A.f d. 2 suction lines on separate boards (up to 2 screw compressors on line 1 and scroll or piston compressors on line 2), 1 condenser line on a separate board: g. 2 suction lines on the same board (scroll or piston compressors), 2 condenser lines on separate boards: 4 J25 BMS2 C7 C8 J15 J14 J10 3 2 NC8 C7 C4 J13 NO8 NO7 C4 C1 NO6 NO5 NO4 C1 NO3 NO2 NO1 I/O J12 J11 pLAN I/O 1 J26 FBus2 I/O pR300 B M S card IDC1 ID8 ID7 ID6 ID5 ID4 Y4 Y3 ID3 ID2 ID1 Y2 VG0 VG GND U5 GND U4 +VDC J5 Y1 J4 J3 GND U3 U2 G0 J2 U1 G +Vterm GND J24 +5 VREF FieldBus card J1 J12 J11 pLAN 3 2 J25 BMS2 3 2 C8 C7 NC8 C7 J14 4 J26 FBus2 NO8 C4 J13 J10 1 NO7 C4 C1 NO6 NO5 C1 J12 J11 pLAN NO4 NO3 NO2 NO1 NC8 C8 C7 C7 4 pR300 J15 J14 J13 J10 J25 BMS2 NO8 NO7 C4 NO6 NO5 NO4 C4 C1 NO3 NO2 NO1 C1 pLAN J15 1 J26 FBus2 pLAN pLAN pR300 pR300 B M S car d IDC1 ID8 ID7 ID6 ID5 ID4 ID3 Y4 ID2 ID1 J5 Y3 VG0 VG GND U5 GND U4 +VDC Y1 J4 J3 GND U3 U2 J2 U1 +5 VREF G0 I/O GND G J24 +Vterm IDC1 ID8 ID7 ID6 J1 ID5 ID4 Y4 Y3 ID3 ID2 ID1 Y2 Y1 VG0 VG GND U5 GND U4 +VDC FieldBus card J5 Y2 B M S car d J4 J3 GND U3 U2 J2 U1 G0 G GND J24 +5 VREF +Vterm FieldBus card J1 I/O pR300 Fig. A.d I/O I/O e. 2 suction lines on the same board (scroll or piston compressors), 1 condenser line on a separate board: Fig. A.g h. 2 suction lines on separate boards (scroll or piston compressors), 2 condenser lines (one for each suction line board) 4 3 2 NC8 C8 C7 C7 C4 J14 J13 J10 J25 BMS2 NO8 NO7 C4 NO6 NO5 C1 J12 NO4 C1 NO3 NO2 NO1 I/O J11 pLAN J15 1 I/O I/O J26 FBus2 pLAN pR300 3 2 2 C8 C7 C7 3 NC8 J15 J14 4 J25 BMS2 J26 FBus2 NO8 C4 J13 J10 1 NO7 C4 NO6 NO5 C1 J12 J11 pLAN NO4 C1 NO3 NO2 NO1 C8 C7 C7 J15 J14 4 NC8 C4 J13 J10 J25 BMS2 NO8 C4 NO7 C1 NO6 NO5 C1 NO4 NO3 J12 J11 pLAN IDC1 ID8 ID7 ID6 ID5 ID4 ID3 Y4 Y3 Y2 ID2 ID1 Y1 VG0 VG GND U5 GND U4 +VDC J5 NO2 B M S card J4 J3 GND U3 U2 J2 U1 +5 VREF GND +Vterm 1 J26 FBus2 pLAN pR300 B M S c ard IDC1 ID8 ID7 ID6 ID5 ID4 ID3 Y4 Y3 ID2 J5 ID1 VG0 VG GND U5 GND U4 +VDC Y1 J4 J3 GND U3 U2 J2 U1 G0 +5 VREF G J24 GND IDC1 ID8 ID7 J1 ID6 ID5 ID4 ID3 Y4 ID2 ID1 Y3 Y2 Y1 VG0 VG GND U5 GND U4 +VDC FieldBus card J5 +Vterm B M S card J4 J3 GND U3 U2 J2 U1 G0 G +5 VREF +Vterm FieldBus card J24 Y2 pR300 J1 GND G0 G J24 NO1 FieldBus card J1 pR300 I/O I/O I/O I/O Fig. A.h Fig. A.e 83 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG driver on pRack pR300 or external EVD EVO driver suitably integrated into the system (Fieldbus communication over RS485). 2 suction lines on separate boards (scroll or piston compressors), 2 condenser lines on separate boards 3 2 C8 C7 C7 2 NC8 NO8 NO7 C4 NO6 NO5 C4 3 1 J26 FBus2 B M S c ard ID7 ID8 IDC1 C8 NC8 ID8 ID6 ID5 NO8 Y4 Y3 ID4 ID3 ID2 Y2 ID1 Y1 C4 VG0 C4 NO6 VG C1 GND NO3 U5 NO2 GND U4 +VDC J5 NO5 J4 J3 GND U3 U2 U1 G0 G J2 +5 VREF IDC1 NC8 +Vterm ID8 J24 GND ID7 ID6 C8 ID5 NO8 ID4 ID3 Y4 Y3 ID2 ID1 J1 ID7 FieldBus card J5 Y2 Y1 VG0 VG GND U5 GND U4 +VDC GND NO4 4 B M S c ard J4 J3 U3 U2 U1 G0 G +5 VREF GND +Vterm J2 J15 J14 J13 J25 BMS2 pR300 FieldBus card J24 C1 J12 J11 pLAN J10 1 J26 FBus2 pR300 J1 NO3 C1 J15 NO2 C8 C7 C7 J14 4 NC8 C4 J13 J25 BMS2 NO8 C4 NO7 C1 NO6 NO5 C1 NO3 NO2 NO1 J12 J11 pLAN J10 pLAN I/O pLAN NO1 I/O NO4 i. J13 J14 J10 4 J25 BMS2 3 2 J15 J12 J11 pLAN C7 NO7 NO4 C7 3 2 1 J26 FBus2 B M S c ard IDC1 ID6 ID5 Y4 Y3 ID4 ID3 ID2 ID1 J5 Y2 VG0 VG GND U5 GND U4 +VDC Y1 J4 J3 GND U3 U2 U1 G0 G J2 +5 VREF +Vterm J24 GND IDC1 ID8 ID7 J1 ID6 ID5 ID4 ID3 Y4 Y3 ID2 ID1 J5 Y2 Y1 VG0 VG GND U5 GND U4 +VDC GND FieldBus card B M S c ard J4 J3 U3 U2 U1 G0 G +5 VREF GND +Vterm J2 J15 J14 4 J25 BMS2 pR300 FieldBus card J24 J13 J10 1 J26 FBus2 pR300 J1 NO1 C1 C7 C7 NO7 C4 NO6 NO5 NO4 C4 C1 NO3 NO2 C1 NO1 pLAN J12 J11 pLAN I/O I/O Fig. A.i j. Fig. A.k 2 suction lines on separate boards (scroll or piston compressors), 2 condenser lines (line 1 on separate board, line 2 on common board with suction) C8 ID8 4 3 2 NC8 NO8 J14 J10 J25 BMS2 C7 NO7 C7 C4 C4 NO6 NO5 J13 ID7 J11 pLAN NO4 C1 C1 NO3 NO2 NO1 I/O J12 J15 1 J26 FBus2 pR300 B M S card IDC1 J13 J14 4 J25 BMS2 3 2 NC8 C7 C7 C4 NO7 NO6 NO5 NO4 C4 C1 NO3 NO2 C1 NC8 J12 J11 pLAN J10 1 C8 2 J26 FBus2 NO8 3 I/O J15 ID8 4 C8 NO8 J14 J10 J25 BMS2 C7 NO7 C7 C4 NO6 J13 ID7 J11 pLAN NO5 C4 J12 NO4 C1 NO3 NO2 C1 NO1 pLAN NO1 ID6 ID5 Y4 Y3 Y2 ID4 ID3 ID2 ID1 VG0 VG GND U5 GND U4 +VDC J5 Y1 J4 J3 GND U3 U2 J2 U1 G0 G GND +Vterm J24 +5 VREF FieldBus card J1 J15 1 J26 FBus2 pLAN pR300 pR300 B M S card IDC1 ID6 ID5 ID4 ID3 ID2 ID1 Y4 J5 Y3 VG0 VG GND U5 GND U4 +VDC Y1 J4 J3 GND U3 U2 J2 U1 G0 G +5 VREF +Vterm J24 GND IDC1 ID8 ID7 J1 ID6 ID5 Y4 Y3 Y2 ID4 ID3 ID2 ID1 Y1 VG0 VG GND U5 GND U4 +VDC FieldBus card J5 Y2 B M S card J4 J3 GND U3 U2 J2 U1 +5 VREF G0 G J24 GND +Vterm FieldBus card J1 I/O I/O Fig. A.l Fig. A.j Legenda: A.2 Special configurations for subcritical CO2 systems, ac. Description Probe type Text Outside temperature NTC - HP PDL1 Discharge pressure line 1 4-20 mA 0-18.2 barg (medium temperature) TDL1 Discharge temperature line 1 NTC - HF (medium temperature) PSL1 Suction pressure line 1 4-20 mA 0-7 barg (medium temperature) TSL1 Suction temperature line 1 NTC - HF (medium temperature) PE Heat exchanger evaporation Ratiometric -1-9.3 pressure barg TGS Heat exchanger superheated NTC – HF gas temperature PDL2 Discharge pressure line 2 4-20 mA 0-44.8 barg (low temperature) TDL2 Discharge temperature line 2 NTC – HF (low temperature) PSL2 Suction pressure line 2 (low 4-20 mA 0-44.8 barg temperature) TSL2 Suction temperature line 2 NTC - HF (low temperature) cascade and pumped systems A.2.1 Cascade The crucial aspect of this type of system is the cascade heat exchanger, normally a plate heat exchanger, which controls the condensing stage of the CO2 system. At times there are two heat exchangers, so as to improve control at low loads and increase safety, and these are normally controlled by EXV electronic expansion valves with stepper motors. In these applications, as well as traditional control based on suction superheat, there is also integration with the low temperature rack, directly when the rack controller has a built-in driver, or via serial communication for external EVD EVO drivers. Given the nature of the refrigerant, condensed liquid CO2 needs to be monitored in order to ensure good performance and protection. Up to 2 heat exchangers can be connected via Fieldbus to the pRack controller, with a driver for each heat exchanger. The drivers are connected to the board that manages the low temperature suction line. Up to 6 control steps can be configured for connecting other drivers controlled via digital input for superheat control. There can be maximum two plate heat exchangers used to condense CO2, and the expansion valve is managed using the built-in pRack +0300025EN rel. 1.5 - 17.02.2020 84 Notes To control discharge temperature (opt.) Can be used as backup for PE To control suction superheat (opt.) To control discharge temperature (opt.) To control suction superheat (opt.) ENG The exchange of information between compressor rack and heat exchanger allows traditional superheat control to be augmented by factors that are vital for this type of system, such as variation in low temperature compressor rack cooling capacity and the trend in CO2 condensing pressure. (pRack only sends the control parameters and the cooling capacity to vary). The drivers connected via serial have advantages over external configurations (via digital inputs) as the parameters are easier to set (the driver screens can be accessed directly from the pRack controller) and are more responsive when unit cooling capacity changes considerably due to due peaks in demand. The drivers connected via serial can use an estimated percentage of cooling capacity delivered by the circuit to influence normal superheat control. When the variation in capacity exceeds 10% or when control commences, the driver pre-positions the valve to get closer to the optimum opening. This operation ensures good control of condensing pressure on the low temperature rack (S3 or A, configurable) when compressor on line 2 start. If the compressors on the low temperature rack are controlled by inverter, capacity modulation will be much more linear and anticipation of valve movements will have less influence (in terms of pre-positioning). If using one or more single drivers, the condensing pressure probe can be connected directly to the EVD EVO driver (S3), allowing just one pressure probe to be used for condenser control and for the EVD EVO driver safety procedure, which tends to open the valve when the CO2 condensing temperature is too high. In this case, the CO2 condensing pressure probe connected to pRack is optional. This function can be used with the following configurations: • pRack pR300 with built-in driver and just one heat exchanger • pRack pR300 with single external EVD EVO driver • pRack pR300 with 2 single external EVD EVO drivers • pRack pR300 with 2 EVD EVO drivers, one of which built-in (only 1 exchanger) and 1 single external. Note: carefully check the pressure control settings; for general uniformity of the software, automatic set point selection is not featured for the different types of control and different types of refrigerant. For example, the suggested default set point for the low temperature compressors is 3.5 bars; in a cascade system (subcritical CO2) with R744 natural refrigerant, the reference pressure values are around 11 bars. Together with the set point, the probe limits and probe alarm thresholds will be correctly configured. • Cascade, 2 suction lines, 2 condenser lines (external driver for managing the heat exchanger on the second line), single board; EEV FBUS S1 S2 S3 I/O EVD evolution pR300 I/O I/O Fig. A.m • Cascade, 2 suction lines, 2 condenser lines (built-in driver for managing the heat exchanger on the second line), single board; Note: if serial communication between driver and pRack is interrupted, the condensing pressure probe on the pRack, connected to the driver, will be disconnected and the safety procedures featured on pRack will be activated (alarm signal, use of the backup probe if configured, fan operation overridden to a preset value). One DRIVER is needed for each valve; if a Twin Driver is used, this will be managed as a single driver. The connection should be done on the first valve too (EXV1- J27 if a built-in driver is used). I/O EEV Details of the pRack configuration Wizard pR300 I/O I/O Fig. A.n After having selected this type of configuration, the software takes a few seconds to pre-configure some settings relating to a typical cascade system, i.e. the second condenser line; the Wizard will prompt whether to control the CO2 condenser using the fans or the new EVS system: 85 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG • Cascade, 2 suction lines, 2 condenser lines (built-in driver for managing the heat exchanger on the second line), double board; EEV EVD FBUS evolution C8 C7 C4 C7 2 NC8 NO7 NO6 C4 C1 C1 NO5 NO4 NO3 NO8 3 J15 1 J26 FBus2 B M S c ard IDC1 ID6 ID5 ID4 ID3 ID2 ID1 Y4 Y3 J5 Y2 VG0 VG GND U5 GND U4 +VDC Y1 J4 J3 GND U3 U2 G0 J2 U1 +5 VREF G I/O J24 GND IDC1 ID8 ID7 ID6 ID5 ID4 ID3 Y4 ID2 ID1 Y3 J1 +Vterm FieldBus card J5 Y2 Y1 VG0 VG GND U5 GND U4 +VDC J14 4 B M S car d J4 J3 GND U3 U2 U1 G0 G +Vterm +5 VREF GND J2 J13 J25 BMS2 pR300 FieldBus card J24 NO2 J12 J11 pLAN J10 pLAN pR300 J1 NO1 J15 1 ID8 2 J26 FBus2 ID7 3 C8 C7 C7 4 NC8 C4 J14 J13 J10 J25 BMS2 NO8 C4 NO7 NO6 C1 J12 J11 pLAN NO5 C1 NO4 NO3 NO2 NO1 S1 S2 S3 I/O I/O Fig. A.o • Cascade, 2 suction lines, 2 condenser lines (built-in driver for managing Fig. A.r the heat exchanger on the second line), double board; pRack pR300 L1 connections ac. Description Probe type Notes Text Outside temperature NTC - HP PDL1 Condensing pressure line 1 4-20 mA 0-18.2barg (medium temperature) TDL1 Discharge temperature line 1 NTC - HF To control discharge (medium temperature) temperature PSL1 Suction pressure line 1 4-20 mA 0-10barg To control low pressure (medium temperature) alarm TSL1 Suction temperature line 1 NTC - HF To control suction (medium temperature) superheat PREC CO2 receiver pressure 4-20 mA 0-10barg To control medium temperature compressors EEV J13 4 3 2 C8 NC8 NO8 J15 J14 J10 J25 BMS2 C7 C7 C4 NO7 NO6 NO5 C4 J12 J11 pLAN NO4 C1 NO3 NO2 C1 NO1 I/O 1 J26 FBus2 pLAN pR300 pR300 B M S car d IDC1 ID8 ID7 ID6 ID5 ID4 ID3 ID2 Y4 ID1 Y3 J5 Y2 VG0 VG GND U5 GND U4 +VDC Y1 J4 J3 GND U3 U2 J2 U1 G0 G +5 VREF J24 GND +Vterm FieldBus card J1 I/O I/O Tab. 11.b pRack pR300T L2 connections ac. Description Probe type TDL2 Discharge temperature line 2 NTC – HF (low temperature) PSL2 Suction pressure line 2 (low 4-20 mA 0-44.8barg temperature) TSL2 Suction temperature line 2 (low NTC - HF temperature) Fig. A.p A2.2 Pumped Less used than traditional cascade subcritical systems, this solution limits the use of HFC refrigerants to the equipment rooms. The medium temperature units are supplied with pumped liquid CO2, while the low temperature units are fitted with expansion valves. The CO2 is cooled by a dedicated chiller (NH3 or r134a) inside a tank, normally with a tube bundle evaporator. In addition to traditional systems, these also include management of the pumps that deliver the liquid CO2 to the medium temperature evaporators, where it does not expand but rather is only superheated and returns to the receiver in a semi-liquid state. To control suction superheat Tab. 11.c EVD EVO connections ac. PREC PE Description Discharge pressure line 2 (low temperature) Heat exchanger evaporation pressure Probe type 4-20 mA 0-44.8barg Ratiometric -1-9.3barg TGS Heat exchanger superheated gas temperature NTC – HF Tab. 11.d Dettagli Wizard della configurazione pRack Fig. A.q pRack +0300025EN rel. 1.5 - 17.02.2020 Notes To control discharge temperature (opt.) 86 ENG • Pumped, 2 suction lines (built-in driver for managing the heat exchanger In this type of system, it is important to coordinate operation of the medium temperature rack with tube bundle evaporator control, to prevent low pressure problems. Pressure control inside the receiver is the main task; given the quantity of refrigerant contained and consequently its significant inertia, it is essential to activate the compressors based on the receiver pressure, and medium temperature rack suction pressure will only be monitored for safety, to prevent low pressure problems. on the first line), 1 condenser line, single board; I/O EEV Medium temperature circuit control Medium temperature circuit control uses a pressure sensor installed on the low temperature receiver; in order to exploit this sensor, pRack needs to use an auxiliary control function available under COMPRESSORS®LINE 1®CONTROL, in screen Cab20 pR300 I/O I/O Fig. A.t • Pumped, 2 suction lines (external driver for managing the heat exchanger This screen is used to enable the function, set the required type of control and the refrigerant in the auxiliary circuit. An “auxiliary” control probe needs to be configured under INPUTS/ OUTPUTS®STATUS®ANALOG INPUTS in a free position on the controller. The high and low auxiliary pressure/temperature probe alarms need to be set under COMPRESSORS®LINE 1®ALARMS, checking the control parameters. on the first line), 1 condenser line, double board EEV EVD FBUS evolution C8 C7 C7 J14 4 3 2 NC8 C4 NO8 C4 NO7 C1 NO6 NO5 C1 NO4 NO3 J13 J25 BMS2 J15 1 J26 FBus2 pLAN pR300 B M S car d IDC1 ID6 ID5 ID4 ID3 Y4 ID2 ID1 Y1 VG0 VG GND U5 GND U4 +VDC GND J5 Y3 J4 J3 U3 U2 J2 U1 G0 G GND J24 +5 VREF +Vterm IDC1 ID8 ID7 J1 ID6 ID5 ID4 Y4 Y3 ID3 ID2 ID1 Y2 Y1 VG0 VG GND U5 GND U4 +VDC FieldBus card J5 Y2 B M S card J4 J3 GND U3 U2 J2 U1 G0 G GND J24 +5 VREF +Vterm FieldBus card J1 I/O I/O Fig. A.u • Pumped, 2 suction lines (built-in driver for managing the heat exchanger on the first line), 1 condenser line, double board EEV 3 2 C8 C7 NC8 NO8 J15 J14 4 J25 BMS2 pR300 1 J26 FBus2 pR300 B M S c ar d IDC1 ID8 ID7 ID6 ID5 ID4 ID3 ID2 Y4 ID1 Y3 J5 Y2 VG0 VG GND U5 GND U4 +VDC Y1 J4 J3 GND U3 U2 G0 J2 U1 +5 VREF J24 GND G I/O +Vterm FieldBus card J1 EEV C7 J13 J10 pLAN exchanger on the first line), 1 condenser line, single board; NO7 C4 NO6 NO5 C4 J12 J11 pLAN NO4 C1 NO3 NO2 NO1 C1 I/O • Pumped, 2 suction lines (external driver for managing the heat I/O EVD evolution S1 S2 S3 FBUS NO2 J12 J11 pLAN J10 pR300 Note: One DRIVER is needed for each valve; if a Twin Driver is used, this will be managed as a single driver. The connection should be done on the first valve too (EXV1- J27 if a built-in driver is used). I/O NO1 J15 1 ID8 2 J26 FBus2 ID7 3 C8 C7 C7 4 NC8 C4 J14 J13 J10 J25 BMS2 NO8 NO7 C4 NO6 NO5 C1 J12 J11 pLAN NO4 C1 NO3 NO2 EVD EVO and EXV drivers Management of the tube bundle evaporator is critical in these types of applications, and the size of the evaporator, inertia of the load and proximity to the compressors require very fine control, which needs to adapt rapidly when the compressors are started or stopped, respond gradually to changes of load, not flood the compressors, and protect against low suction pressure alarms. Functions on the EVD EVO driver, such as low superheat, low suction temperature, low suction pressure and high CO2 condensing pressure protection, therefore need to be correctly calibrated based on system features (number and type of compressors, size of the evaporator and the receiver, whether there are receivers on the suction line, system dynamics). All these settings are found under OTHER FUNCTIONS®EVS on the board that manages suction line 1. NO1 S1 S2 S3 I/O Fig. A.v Note: don’t configure the second condensing line. pR300 I/O I/O Fig. A.s 87 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG A.3 System configurations with more than one pLAN board A.3.2 Setting the address of the pRack pR300 board The pLAN address of the pRack boards can be set from any pGD1 terminal, using the following procedure: 1. set address 0 on the terminal (see the previous paragraph for details on how to set this address); 2. power down the pRack pR300 board; 3. disconnect any pLAN connections to other boards from the pRack pR300 board; 4. connect the terminal to the pRack pR300 board; If the system configuration involves the connection of more than one board in a pLAN, the addresses must be set correct before select a solution of configuration. For the addresses to be assigned to the pRack pR300 boards see Appendix A.1. pRack pR300 can use two user terminals (as well as a built-in terminal) with addresses 31 and 32. The default user terminal address is 32, so only if a second terminal is required must the address of this be set to 31, as described below. The address of the terminal is also required when having to set the address of the pRack pR300 boards, when multiple boards are connected to the pLAN. After having correctly connected and configured the pLAN network of pRack pR300 boards, the system can be configured as described in paragraph 4.1. 5. power up the pRack pR300 board, while pressing the and buttons on the terminal together. After a few seconds the pRack pR300 board begins the start-up sequence and the display shows a screen similar to the one below: #################### selftest please wait #################### A.3.1 Setting the address of the terminal The pRack pR300 user terminal is supplied with the default address 32, allowing the terminal to be used without requiring any additional operations; nonetheless, in order to use an additional terminal or configure the pLAN address of the boards, it needs to be changed according to the following procedure: 1. power the terminal via the special telephone connector; 2. press the 3 buttons, , and together for at least 5 seconds; the terminal will display a screen similar to the one below, with the cursor flashing in the top left corner: 6. when this screen is displayed, wait 10 seconds and then release the buttons; 7. the pRack pR300 board interrupts the start-up sequence and shows a configuration screen, similar to the one below: pLAN address: 0 UP: increase DOWN: decrease ENTER: save & exit Display address setting.........:32 I/O Board address:01 3. press once: the cursor will move to the “Display address setting” field; 4. select the desired value using and , and confirm by pressing again; if the value selected is different from the value saved, the following screen will be displayed and the new value will be saved to the display’s permanent memory. Then set the pLAN address using the and buttons on the terminal. 8. Confirm the address by pressing : the pRack pR300 board completes the start-up sequence and uses the set address. A3.3 Example of configuring a system with 2 suction and condenser lines using the Wizard Display address changed Below is a possible example of using the Wizard to configure a typical system like the one shown in the figure, with 2 suction lines and 2 condenser lines on different boards: Note: if the address field is set to 0, the “I/O Board address” field is no longer displayed, as it has no meaning.. Display address changed C8 C7 C7 2 NC8 NO7 C4 C1 NO6 C1 NO5 NO4 NO3 C4 3 J15 1 J26 FBus2 B M S c ar d IDC1 ID6 ID5 ID4 Y4 ID3 ID2 ID1 Y3 J5 Y2 VG0 VG GND U5 GND U4 +VDC Y1 J4 J3 GND U3 U2 J2 U1 G0 G +5 VREF J24 GND IDC1 ID8 ID7 ID6 ID5 ID4 ID3 ID2 ID1 Y4 Y3 I/O +Vterm J1 J5 Y2 Y1 VG0 VG GND U5 GND U4 +VDC FieldBus card B M S c ard J4 J3 GND U3 U2 U1 G0 G +5 VREF GND +Vterm J2 J14 4 J25 BMS2 pR300 FieldBus card J24 J13 J10 pR300 J1 NO2 J12 J11 pLAN pLAN NO1 C8 C7 NC8 J15 1 NO8 2 J26 FBus2 ID8 3 I/O ID7 • if the settings are not made correctly, the text and the images on the I/O Fig. A.t The preliminary operations to be completed before configuration are as follows: 1. with the boards not connected in the pLAN, power up the second pRack board and set the pLAN address to 2 (for details see Appendix A.2) 2. power down and connect the two boards in the pLAN, plus any terminals, as described in paragraph 3.7 3. power up the boards and wait for the Wizard selection screen to be displayed. If the terminal detects inactivity of the entire pLAN network, that is, it does not receive any messages from the network for 10 seconds consecutively, it clears the display and shows the following message: NO LINK pRack +0300025EN rel. 1.5 - 17.02.2020 C7 J14 4 J25 BMS2 NO8 C4 J13 J10 display will be displayed incorrectly and out of order. • if during this operation the terminal detects inactivity of the pRack board whose output is being displayed, the display is cleared and a message similar to the one below is shown. NO7 C4 C1 NO6 NO5 C1 J12 J11 pLAN NO4 NO3 NO2 NO1 I/O Important 88 ENG Then select the type of system as SUCTION & CONDENSER: After having answered the questions for the configuration of the second suction line, the software then asks if there is a pLAN board dedicated to condenser line 1. In the case shown in the example, answer NO. Set the type of compressors and control for suction line 1, answering the questions prompted by the pRack pR300 software, e.g.: After having configured condenser line 1, the software asks if condenser line 2 is used; answer YES: After having configured the second condenser line, the software offers the option to automatically configure the I/Os (choosing YES), as described in par. 4.1.4. If choosing NO, each individual I/O needs to be configured manually at the end of the wizard. In addition, the software asks the user whether or not to display a summary of the settings made: If the settings are correct, the set values can be installed: After having configured suction line 1, a prompt will be shown to configure another suction line, obviously the answer is YES: After waiting a few seconds, the unit can be started. To the next question, which prompts if there is a pRack board dedicated to the second line, answer YES; in this way, the pRack pR300 software prepares to configure the board with address 2 in the pLAN: Note: after having configured pRack pR300, the device needs to be switched off and on again to permanently save the new data. 89 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG A.4 Alarm table Code ALA01 ALA02 ALA03 ALA04 ALA05 ALA06 ALA07 ALA08 ALA09 ALA10 ALA11 ALA12 ALA13 ALA14 ALA15 ALA16 ALA17 ALA18 ALA19 ALA20 ALA21 ALA22 ALA23 ALA24 ALA25 ALA26 ALA27 ALA28 ALA29 ALA30 ALA31 ALA32 ALA33 ALA34 ALA35 ALA36 ALA39 ALA40 ALA41 ALA42 ALB01 ALB02 ALB03 ALB04 ALB05 ALB06 ALB07 ALB08 ALB09 ALB10 ALB11 Description Discharge temperature probe malfunction Condensing pressure probe malfunction Outside temperature probe malfunction Generic probe malfunction A, PLB1 Generic probe malfunction B, PLB1 Generic probe malfunction C, PLB1 Generic probe malfunction D, PLB1 Generic probe malfunction E, PLB1 Generic probe malfunction A, PLB2 Generic probe malfunction B, PLB2 Generic probe malfunction C, PLB2 Generic probe malfunction D, PLB2 Generic probe malfunction E, PLB2 Generic probe malfunction A, PLB3 Generic probe malfunction B, PLB3 Generic probe malfunction C, PLB3 Generic probe malfunction D, PLB3 Generic probe malfunction E, PLB3 Generic probe malfunction A, PLB4 Generic probe malfunction B, PLB4 Generic probe malfunction C, PLB4 Generic probe malfunction D, PLB4 Generic probe malfunction E, PLB4 Suction pressure probe malfunction Suction temperature probe malfunction Room temperature probe malfunction Condensing pressure probe malfunction, line 2 Discharge temperature probe malfunction, line 2 Suction pressure probe malfunction, line 2 Suction temperature probe malfunction, line 2 Condensing pressure backup probe malfunction Condensing pressure backup probe malfunction, line 2 Suction pressure backup probe malfunction Suction pressure backup probe malfunction, line 2 Common oil temperature probe malfunction Common oil temperature probe malfunction, line 2 Discharge temperature probe malfunction, compressors 1 to 6 Discharge temperature probe malfunction, compressors 1 to 6, line 2 Oil temperature probe malfunction compressors 1 to 6, line 1 Oil temperature probe malfunction compressor 1, line 2 Low suction pressure from pressure switch High condensing pressure from pressure switch Low condensing pressure from probe High condensing pressure from probe Liquid level Common oil differential Common fan circuit breaker Low suction pressure from pressure switch, line 2 High condensing pressure from pressure switch, line 2 Low condensing pressure from probe, line 2 High condensing pressure from probe, line 2 Reset Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Semiautomatic Manual/automatic Automatic Automatic Automatic Automatic Automatic Semiautomatic Manual/automatic Automatic Automatic Delay 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s 60s Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Alarm relay R2 R1 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R1 R2 R2 R1 R2 R1 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R1 R1 R1 R1 R2 R2 Settable R1 R1 R1 R1 ALB12 ALB13 ALB14 ALB15 ALB16 ALB17 ALB18 ALB21 ALB22 ALC01 ALC02 ALC03 ALC04 ALC05 ALC06 ALC07 ALC08 ALC09 ALC10 ALC11 ALC12 ALC13 ALC14 ALC15 ALC16 ALC17 ALC18 ALC19 ALC20 ALC21 ALC22 ALC23 ALC24 ALC25 ALC26 ALC27 ALC28 ALC29 ALC30 ALC31 ALC32 ALC33 ALC34 ALC35 Liquid level, line 2 Common oil differential, line 2 Common fan circuit breaker, line 2 High suction pressure from probe Low suction pressure from probe High suction pressure from probe, line 2 Low suction pressure from probe, line 2 Shutdown to prevent high pressure Shutdown to prevent high pressure, line 2 Alarm 1, compressor 1 Alarm 2, compressor 1 Alarm 3, compressor 1 Alarm 4, compressor 1 Alarm 5, compressor 1 Alarm 6, compressor 1 Alarm 7, compressor 1 Alarm 1, compressor 2 Alarm 2, compressor 2 Alarm 3, compressor 2 Alarm 4, compressor 2 Alarm 5, compressor 2 Alarm 6, compressor 2 Alarm 7, compressor 2 Alarm 1, compressor 3 Alarm 2, compressor 3 Alarm 3, compressor 3 Alarm 4, compressor 3 Alarm 5, compressor 3 Alarm 6, compressor 3 Alarm 7, compressor 3 Alarm 1, compressor 4 Alarm 2, compressor 4 Alarm 3, compressor 4 Alarm 4, compressor 4 Alarm 5, compressor 4 Alarm 6, compressor 4 Alarm 7, compressor 4 Alarm 1, compressor 5 Alarm 2, compressor 5 Alarm 3, compressor 5 Alarm 4, compressor 5 Alarm 6, compressor 5 Alarm 7, compressor 5 Alarm 7, compressor 5 Automatic Automatic Automatic Automatic Automatic Automatic Automatic Manual Manual Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable R2 R2 Settable R1 R1 R1 R1 R1 R1 Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable pRack +0300025EN rel. 1.5 - 17.02.2020 90 Action Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Related functions disabled Shutdown compressor Shutdown compressor Force fans to 0% Force fans to 100% and compressor stop Shutdown compressors, line 2 Shutdown compressors, line 2 Force fans to 0%, line 2 Force fans to 100% and stop compressor, line 2 Shutdown compressor Shutdown compressors, line 2 Shutdown compressor 1 Shutdown compressor 1 Shutdown compressor 1 Shutdown compressor 1 Shutdown compressor 1 Shutdown compressor 1 Shutdown compressor 1 Shutdown compressor 2 Shutdown compressor 2 Shutdown compressor 2 Shutdown compressor 2 Shutdown compressor 2 Shutdown compressor 2 Shutdown compressor 2 Shutdown compressor 3 Shutdown compressor 3 Shutdown compressor 3 Shutdown compressor 3 Shutdown compressor 3 Shutdown compressor 3 Shutdown compressor 3 Shutdown compressor 4 Shutdown compressor 4 Shutdown compressor 4 Shutdown compressor 4 Shutdown compressor 4 Shutdown compressor 4 Shutdown compressor 5 Shutdown compressor 5 Shutdown compressor 5 Shutdown compressor 5 Shutdown compressor 5 Shutdown compressor 5 Shutdown compressor 5 Shutdown compressor 5 ENG Code ALC36 ALC37 ALC38 ALC39 ALC40 ALC41 ALC42 ALC43 ALC44 ALC45 ALC46 ALC47 ALC48 ALC49 ALC50 ALC51 ALC52 ALC53 ALC54 ALC55 ALC56 ALC57 ALC58 ALC59 ALC60 ALC61 ALC62 ALC63 ALC64 ALC65 ALC66 ALC67 ALC68 ALC69 ALC70 ALC71 ALC72 ALC73 ALC74 ALC75 ALC76 ALC77 ALC78 ALC79 ALC80 ALC81 ALC82 ALC83 ALC84 ALC85 ALC86 ALC87 ALC88 ALC89 ALC90 ALC91 ALC92 ALC93 ALC94 ALC95 ALC96 ALC97 ALC98 ALC99 ALCaa ALCab ALCac ALCad ALCae ALCaf ALCag ALCah ALCai ALCal ALCam AlCan ALCao AlCap ALF01 ALF02 ALG01 ALG02 ALG11 ALG12 ALG13 ALG14 ALG15 ALG16 ALG17 ALG18 ALG19 ALG20 ALG21 ALG22 ALG23 ALG24 ALG25 ALG26 Description Alarm 1, compressor 6 Alarm 2, compressor 6 Alarm 3, compressor 6 Alarm 4, compressor 6 Alarm 5, compressor 6 Alarm 6, compressor 6 Alarm 7, compressor 6 Alarm 1, compressor 7 Alarm 2, compressor 7 Alarm 1, compressor 8 Alarm 2, compressor 8 Alarm 1, compressor 9 Alarm 2, compressor 9 Alarm 1, compressor 10 Alarm 1, compressor 11 Alarm 1, compressor 12 Alarm 1, compressor 1, line 2 Alarm 2, compressor 1, line 2 Alarm 3, compressor 1, line 2 Alarm 4, compressor 1, line 2 Alarm 5, compressor 1, line 2 Alarm 6, compressor 1, line 2 Alarm 7, compressor 1, line 2 Alarm 1, compressor 2, line 2 Alarm 2, compressor 2, line 2 Alarm 3, compressor 2, line 2 Alarm 4, compressor 2, line 2 Alarm 5, compressor 2, line 2 Alarm 6, compressor 2, line 2 Alarm 7, compressor 2, line 2 Alarm 1, compressor 3, line 2 Alarm 2, compressor 3, line 2 Alarm 3, compressor 3, line 2 Alarm 4, compressor 3, line 2 Alarm 5, compressor 3, line 2 Alarm 6, compressor 3, line 2 Alarm 7, compressor 3, line 2 Alarm 1, compressor 4, line 2 Alarm 2, compressor 4, line 2 Alarm 3, compressor 4, line 2 Alarm 4, compressor 4, line 2 Alarm 5, compressor 4, line 2 Alarm 6, compressor 4, line 2 Alarm 7, compressor 4, line 2 Alarm 1, compressor 5, line 2 Alarm 2, compressor 5, line 2 Alarm 3, compressor 5, line 2 Alarm 4, compressor 5, line 2 Alarm 5, compressor 5, line 2 Alarm 6, compressor 5, line 2 Alarm 7, compressor 5, line 2 Alarm 1, compressor 6, line 2 Alarm 2, compressor 6, line 2 Alarm 3, compressor 6, line 2 Alarm 4, compressor 6, line 2 Alarm 5, compressor 6, line 2 Alarm 6, compressor 6, line 2 Alarm 7, compressor 6, line 2 Alarm 1, compressor 7, line 2 Alarm 2, compressor 7, line 2 Alarm 1, compressor 8, line 2 Alarm 2, compressor 8, line 2 Alarm 1, compressor 9, line 2 Alarm 2, compressor 9, line 2 Alarm 1, compressor 10, line 2 Alarm 1, compressor 11, line 2 Alarm 1, compressor 12, line 2 High oil sump temperature, Digital Scroll™ High discharge temperature, Digital Scroll™ High oil dilution, Digital Scroll™ High oil sump temperature, Digital Scroll™, line 2 High discharge temperature, Digital Scroll™, line 2 High oil dilution, Digital Scroll™, line 2 High discharge temperature compressors 1 to 6 High discharge temperature compressors 1 to 6, line 2 Compressor envelope High compressor oil temperature, line 1 High compressor oil temperature, line 2 Fan circuit breaker Fan circuit breaker, line 2 Clock error Extended memory error Generic high temperature alarms 1 to 5, PLB1 Generic high temperature alarms 1 to 5, PLB2 Generic high temperature alarms 1 to 5, PLB3 Generic high temperature alarms 1 to 5, PLB4 Generic low temperature alarms 1 to 5, PLB1 Generic low temperature alarms 1 to 5, PLB2 Generic low temperature alarms 1 to 5, PLB3 Generic low temperature alarms 1 to 5, PLB4 Generic high modulation alarms 6 and 7, PLB1 Generic high modulation alarms 6 and 7, PLB2 Generic high modulation alarms 6 and 7, PLB3 Generic high modulation alarms 6 and 7, PLB4 Generic low modulation alarms 6 and 7, PLB1 Generic low modulation alarms 6 and 7, PLB2 Generic low modulation alarms 6 and 7, PLB3 Generic low modulation alarms 6 and 7, PLB4 Reset Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Automatic Automatic Manual Automatic Automatic Manual/automatic Manual/automatic Automatic Automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic 91 Delay Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable 60s 60s Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Alarm relay Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable R2 R2 R2 R2 R2 R2 R2 R2 R1 R2 R2 R2 R2 R2 R2 Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable Action Shutdown compressor 6 Shutdown compressor 6 Shutdown compressor 6 Shutdown compressor 6 Shutdown compressor 6 Shutdown compressor 6 Shutdown compressor 6 Shutdown compressor 7 Shutdown compressor 7 Shutdown compressor 8 Shutdown compressor 8 Shutdown compressor 9 Shutdown compressor 9 Shutdown compressor 10 Shutdown compressor 11 Shutdown compressor 12 Shutdown compressor 1, line 2 Shutdown compressor 1, line 2 Shutdown compressor 1, line 2 Shutdown compressor 1, line 2 Shutdown compressor 1, line 2 Shutdown compressor 1, line 2 Shutdown compressor 1, line 2 Shutdown compressor 2, line 2 Shutdown compressor 2, line 2 Shutdown compressor 2, line 2 Shutdown compressor 2, line 2 Shutdown compressor 2, line 2 Shutdown compressor 2, line 2 Shutdown compressor 2, line 2 Shutdown compressor 3, line 2 Shutdown compressor 3, line 2 Shutdown compressor 3, line 2 Shutdown compressor 3, line 2 Shutdown compressor 3, line 2 Shutdown compressor 3, line 2 Shutdown compressor 3, line 2 Shutdown compressor 4, line 2 Shutdown compressor 4, line 2 Shutdown compressor 4, line 2 Shutdown compressor 4, line 2 Shutdown compressor 4, line 2 Shutdown compressor 4, line 2 Shutdown compressor 4, line 2 Shutdown compressor 5, line 2 Shutdown compressor 5, line 2 Shutdown compressor 5, line 2 Shutdown compressor 5, line 2 Shutdown compressor 5, line 2 Shutdown compressor 5, line 2 Shutdown compressor 5, line 2 Shutdown compressor 6, line 2 Shutdown compressor 6, line 2 Shutdown compressor 6, line 2 Shutdown compressor 6, line 2 Shutdown compressor 6, line 2 Shutdown compressor 6, line 2 Shutdown compressor 6, line 2 Shutdown compressor 7, line 2 Shutdown compressor 7, line 2 Shutdown compressor 8, line 2 Shutdown compressor 8, line 2 Shutdown compressor 9, line 2 Shutdown compressor 9, line 2 Shutdown compressor 10, line 2 Shutdown compressor 11, line 2 Shutdown compressor 12, line 2 Shutdown compressor Shutdown compressor Shutdown compressor Shutdown compressor Shutdown compressor Shutdown compressor Related functions disabled Related functions disabled Shutdown compressor Shutdown fans Shutdown fans Related functions disabled Related functions disabled - pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Code ALG27 ALG28 ALG29 ALG30 ALG31 ALG32 ALG33 ALG34 ALH01 ALH02 ALO02 ALT01 ALT02 ALT03 ALT04 ALU01 ALU02 ALW01 Description Normal alarm generic functions 8/9, PLB1 Serious alarm generic functions 8/9, PLB1 Normal alarm generic functions 8/9, PLB2 Serious alarm generic functions 8/9, PLB2 Normal alarm generic functions 8/9, PLB3 Serious alarm generic functions 8/9, PLB3 Normal alarm generic functions 8/9, PLB4 Serious alarm generic functions 8/9, PLB4 ChillBooster fault ChillBooster fault, line 2 pLAN malfunction Compressor maintenance request Compressor maintenance request, line 2 ChillBooster maintenance request ChillBooster maintenance request, line 2 Configuration not allowed Control probes missing High pressure prevent warning Reset Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic Automatic Automatic Automatic Manual Manual manual manual Automatic Automatic Automatic Delay Settable Settable Settable Settable Settable Settable Settable Settable Settable Settable 60s 0s 0s Not featured Not featured Settable Alarm relay Settable Settable Settable Settable Settable Settable Settable Settable R2 R2 R1 Not featured Not featured Not featured Not featured Not featured Not featured Not featured ALW02 High pressure prevent warning, line 2 Automatic Settable Not featured ALW03 ALW04 ALW05 ALW06 ALW07 ALW08 ALW09 ALW10 ALW11 ALW12 ALW13 ALE01 ALE01 ALE01 ALE02 ALE02 ALE02 ALE03 ALE03 ALE03 ALE04 ALE04 ALE04 ALE05 ALE05 ALE05 ALE05 ALE05 ALE05 ALE05 ALE07 ALE07 ALE07 ALE07 ALE07 ALE07 ALE07 ALE08 ALE08 ALE08 ALE08 ALE08 ALE08 ALE08 ALE10 ALE10 ALE10 ALE10 ALE10 ALE10 ALE10 ALE11 ALE12 ALE13 ALE14 Compressor inverter warning Compressor inverter warning, line 2 Fan inverter warning Fan inverter warning, line 2 Envelope warning: refrigerant not compatible with compressor series Envelope warning: custom envelope not configured Envelope warning: suction or condensing probes not configured Low superheat warning Low superheat warning, line 2 Warning, ChillBooster operating without outside sensor Warning, ChillBooster operating without outside sensor, line 2 EEV motor error on Driver 1 High condensing temperature on Driver 1 Low suction temperature on Driver 1 Low superheat on Driver 1 Low operating pressure on Driver 1 Maximum operating pressure on Driver 2 EEV motor error on Driver 2 High condensing temperature on Driver 2 Low suction temperature on Driver 2 Low superheat on Driver 2 Low operating pressure on Driver 2 Maximum operating pressure on Driver 2 EEPROM error on Driver 1 in PLB1 Probe S1 error on Driver 1 in PLB1 Probe S2 error on Driver 1 in PLB1 Probe S3 error on Driver 1 in PLB1 Probe S4 error on Driver 1 in PLB1 Offline error on Driver 1 in PLB1 Battery error on Driver 1 in PLB1 EEPROM error on Driver 1 in PLB3 Probe S1 error on Driver 1 in PLB3 Probe S2 error on Driver 1 in PLB3 Probe S3 error on Driver 1 in PLB3 Probe S4 error on Driver 1 in PLB3 Offline error on Driver 1 in PLB3 Battery error on Driver 1 in PLB3 EEPROM error on Driver 2 in PLB1 Probe S1 error on Driver 2 in PLB1 Probe S2 error on Driver 2 in PLB1 Probe S3 error on Driver 2 in PLB1 Probe S4 error on Driver 2 in PLB1 Offline error on Driver 2 in PLB1 Battery error on Driver 2 in PLB1 EEPROM error on Driver 2 in PLB3 Probe S1 error on Driver 2 in PLB3 Probe S2 error on Driver 2 in PLB3 Probe S3 error on Driver 2 in PLB3 Probe S4 error on Driver 2 in PLB3 Offline error on Driver 2 in PLB3 Battery error on Driver 2 in PLB3 Parameter transmission error on Driver 1 Parameter transmission error on Driver 2 FW compatibility error on Driver 1 FW compatibility error on Driver 2 Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Not featured Not featured Not featured Not featured Not featured Not featured Not featured Not featured Not featured 0s 0s Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. 0 0 0 0 Not featured Not featured Not featured Not featured Not featured Not featured Not featured Not featured Not featured Not featured Not featured Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. Config. pRack +0300025EN rel. 1.5 - 17.02.2020 92 Action Disable ChillBooster Disable ChillBooster Shutdown unit Shutdown unit Shutdown unit Shutdown compressor, except minimum load stage Shutdown compressor line 2, except minimum load stage Tab. A.e ENG A.5 I/O Table Other functions Condenser Line 1 Suction Digital inputs Mask Index Ac05, Baack Baa56, Caaah Baada, Caa14 Baa02, Caa01 Baa03, Caa02 Baa04, Caa03 Baa05, Caa04 Baa06, Caa05 Baa07, Caa06 Baa08. Caa07 Baa09, Caa15 Baa10, Caa16 Baa11, Caa17 Baa12, Caa18 Baa13, Caa19 Baa14, Caa20 Baa15, Caa21 Baa17, Caa28 Baa18, Caa29 Baa19, Caa30 Baa20, Caa31 Baa21, Caa32 Baa22, Caa33 Baa23, Caa34 Baa24, Caa40 Baa25, Caa41 Baa26, Caa42 Baa27, Caa43 Baa28, Caa44 Baa29, Caa45 Baa30, Caa46 Baa32, Caa53 Baa33, Caa54 Baa34, Caa55 Baa35, Caa56 Baa36, Caa57 Baa37, Caa58 Baa38, Caa59 Baa39, Caa65 Baa40, Caa66 Baa41, Caa67 Baa42, Caa68 Baa43, Caa69 Baa44, Caa70 Baa45, Caa71 Baa47, Caa78 Baa48, Caa79 Baa49, Caa84 Baa50, Caa85 Baa51, Caa90 Baa52, Caa91 Baa53, Caa95 Baa54, Caa99 Baa55, Caaad Baa58, Caaaj Baa59, Caaak Baadc Baa57 Baaau, Daa01 Baaav, Daa02 Baaaw, Daa03 Baaax, Daa04 Baaay, Daa05 Baaaz, Daa06 Baaba, Daa07 Baabb, Daa08 Baabc, Daa09 Baabd, Daa10 Baabe, Daa11 Baabf, Daa12 Baabg, Daa13 Baabh, Daa14 Baabi, Daa15 Baabj, Daa16 Baabk, Daa17 Baabl Baacx, Egaa01 Baacz Baacl, Caa00, Daa41 Daa43 Daa44 Daa45 Eeaa02 Description Unit ON/OFF line 1 Common low pressure switch line 1 Compressor inverter warning Alarm 1 compressor 1 line 1 Alarm 2 compressor 1 line 1 Alarm 3 compressor 1 line 1 Alarm 4 compressor 1 line 1 Alarm 5 compressor 1 line 1 Alarm 6 compressor 1 line 1 Alarm 7 compressor 1 line 1 Alarm 1 compressor 2 line 1 Alarm 2 compressor 2 line 1 Alarm 3 compressor 2 line 1 Alarm 4 compressor 2 line 1 Alarm 5 compressor 2 line 1 Alarm 6 compressor 2 line 1 Alarm 7 compressor 2 line 1 Alarm 1 compressor 3 line 1 Alarm 2 compressor 3 line 1 Alarm 3 compressor 3 line 1 Alarm 4 compressor 3 line 1 Alarm 5 compressor 3 line 1 Alarm 6 compressor 3 line 1 Alarm 7 compressor 3 line 1 Alarm 1 compressor 4 line 1 Alarm 2 compressor 4 line 1 Alarm 3 compressor 4 line 1 Alarm 4 compressor 4 line 1 Alarm 5 compressor 4 line 1 Alarm 6 compressor 4 line 1 Alarm 7 compressor 4 line 1 Alarm 1 compressor 5 line 1 Alarm 2 compressor 5 line 1 Alarm 3 compressor 5 line 1 Alarm 4 compressor 5 line 1 Alarm 5 compressor 5 line 1 Alarm 6 compressor 5 line 1 Alarm 7 compressor 5 line 1 Alarm 1 compressor 6 line 1 Alarm 2 compressor 6 line 1 Alarm 3 compressor 6 line 1 Alarm 4 compressor 6 line 1 Alarm 5 compressor 6 line 1 Alarm 6 compressor 6 line 1 Alarm 7 compressor 6 line 1 Alarm 1 compressor 7 line 1 Alarm 2 compressor 7 line 1 Alarm 1 compressor 8 line 1 Alarm 2 compressor 8 line 1 Alarm 1 compressor 9 line 1 Alarm 2 compressor 9 line 1 Alarm 1 compressor 10 line 1 Alarm 1 compressor 11 line 1 Alarm 1 compressor 12 line 1 Common oil alarm line 1 Liquid level alarm line 1 Fan inverter warning line 1 Common high pressure switch line 1 Fan overload 1 line 1 Fan overload 2 line 1 Fan overload 3 line 1 Fan overload 4 line 1 Fan overload 5 line 1 Fan overload 6 line 1 Fan overload 7 line 1 Fan overload 8 line 1 Fan overload 9 line 1 Fan overload 10 line 1 Fan overload 11 line 1 Fan overload 12 line 1 Fan overload 13 line 1 Fan overload 14 line 1 Fan overload 15 line 1 Fan overload 16 line 1 Common fan overload line 1 Heat recovery line 1 ChillBooster fault line 1 Enable floating condensing line 1 Set point compensation line 1 Anti noise line 1 Split condenser line 1 Enable floating condensing line 1 Heat recovery activation line 1 Chan. 93 Logic Notes pRack +0300025EN rel. 1.5 - 17.02.2020 Comuni Other functions Condenser Line 2 Suction ENG Mask Index Ac08, Baacy Baaap, Cbaah Baadb, Cba14 Baaar, Cbaaj Baa61, Cba01 Baa62, Cba02 Baa63, Cba03 Baa64, Cba04 Baa65, Cba05 Baa66, Cba06 Baa67, Cba07 Baa68, Cba15 Baa69, Cba16 Baa70, Cba17 Baa71, Cba18 Baa72, Cba19 Baa73, Cba20 Baa74, Cba21 Baa76, Cba28 Baa77, Cba29 Baa78, Cba30 Baa79, Cba31 Baa80, Cba32 Baa81, Cba33 Baa82, Cba34 Baa83, Cba40 Baa84, Cba41 Baa85, Cba42 Baa86, Cba43 Baa87, Cba44 Baa88, Cba45 Baa89, Cba46 Baa91, Cba53 Baa92, Cba54 Baa93, Cba55 Baa94, Cba56 Baa95, Cba57 Baa96, Cba58 Baa97, Cba59 Baa98, Cba65 Baa99, cba66 Baaaa, Cba67 Baaab, Cba68 Baaac, Cba69 Baaad, Cba70 Baaae, Cba71 Baaag, Cba78 Baaah, Cba79 Baaai, Cba84 Baaaj, Cba85 Baaak, Cba90 Baaal, Cba91 Baaam, Cba95 Baaan, Cba99 Baaao, Cbaad Baaas, Cbaak Baadd Baaaq Baabn, Dba01 Baabo, Dba02 Baabp, Dba03 Baabq, Dba04 Baabr, Dba05 Baabs, Dba06 Baabt, Dba07 Baabu, Dba08 Baabv, Dba09 Baabw, Dba10 Baabx, Dba11 Baaby, Dba12 Baabz, Dba13 Baaca, Dba14 Baacb, Dba15 Baacc, Dba16 Baacd, Dba17 Baace Egba01 Baade Baacm, Cbd06, Dbd08 Dba43 Dba44 Dba45 Eeba02 Baacf, Efe16 Baacg, Efe17 Baach, Efe18 Baaci, Efe19 Baacj, Efe20 Baacn Baadf Baadg Description Unit ON/OFF line 2 Common low pressure switch line 2 Compressor inverter warning line 2 Common oil alarm line 2 Alarm 1 compressor 1 line 2 Alarm 2 compressor 1 line 2 Alarm 3 compressor 1 line 2 Alarm 4 compressor 1 line 2 Alarm 5 compressor 1 line 2 Alarm 6 compressor 1 line 2 Alarm 7 compressor 1 line 2 Alarm 1 compressor 2 line 2 Alarm 2 compressor 2 line 2 Alarm 3 compressor 2 line 2 Alarm 4 compressor 2 line 2 Alarm 5 compressor 2 line 2 Alarm 6 compressor 2 line 2 Alarm 7 compressor 2 line 2 Alarm 1 compressor 3 line 2 Alarm 2 compressor 3 line 2 Alarm 3 compressor 3 line 2 Alarm 4 compressor 3 line 2 Alarm 5 compressor 3 line 2 Alarm 6 compressor 3 line 2 Alarm 7 compressor 3 line 2 Alarm 1 compressor 4 line 2 Alarm 2 compressor 4 line 2 Alarm 3 compressor 4 line 2 Alarm 4 compressor 4 line 2 Alarm 5 compressor 4 line 2 Alarm 6 compressor 4 line 2 Alarm 7 compressor 4 line 2 Alarm 1 compressor 3 line 2 Alarm 2 compressor 3 line 2 Alarm 3 compressor 3 line 2 Alarm 4 compressor 3 line 2 Alarm 5 compressor 3 line 2 Alarm 6 compressor 3 line 2 Alarm 7 compressor 3 line 2 Alarm 1 compressor 4 line 2 Alarm 2 compressor 4 line 2 Alarm 3 compressor 4 line 2 Alarm 4 compressor 4 line 2 Alarm 5 compressor 4 line 2 Alarm 6 compressor 4 line 2 Alarm 7 compressor 4 line 2 Alarm 1 compressor 7 line 2 Alarm 2 compressor 7 line 2 Alarm 1 compressor 8 line 2 Alarm 2 compressor 8 line 2 Alarm 1 compressor 9 line 2 Alarm 2 compressor 9 line 2 Alarm 1 compressor 10 line 2 Alarm 1 compressor 11 line 2 Alarm 1 compressor 12 line 2 Liquid level alarm line 2 Fan inverter warning line 2 Common high pressure switch line 2 Fan overload 1 line 2 Fan overload 2 line 2 Fan overload 3 line 2 Fan overload 4 line 2 Fan overload 5 line 2 Fan overload 6 line 2 Fan overload 7 line 2 Fan overload 8 line 2 Fan overload 9 line 2 Fan overload 10 line 2 Fan overload 11 line 2 Fan overload 12 line 2 Fan overload 13 line 2 Fan overload 14 line 2 Fan overload 15 line 2 Fan overload 16 line 2 Common fan overload line 2 Heat recovery line 2 ChillBooster fault line 2 Enable floating condensing line 2 Set point compensation line 2 Anti noise line 2 Split condenser line 2 Enable floating condensing line 2 Heat recovery activation line 2 Generic DI F Generic DI G Generic DI H Generic DI I Generic DI J pRack automatic or manual operation pLoads digital input 1 pLoads digital input 2 Chan. Tab. A.f pRack +0300025EN rel. 1.5 - 17.02.2020 94 Logic Notes ENG Digital outputs Mask Index Bac02, Caa08 Bac03, Caa09 Bac04, Caa10 Bac05, Caa11 Bac07, Caa12 Bac08, Caa22 Bac10, Caa23 Bac11, Caa24 Bac12, Caa25 Bac13, Caa26 Bac15, Caa35 Bac16, Caa36 Bac17, Caa37 Bac18, Caa38 Bac20, Caa39 Bac21, Caa47 Suction Line 1 Bac22, Caa48 Bac23, Caa49 Bac24, Caa50 Bac26, Caa51 Bac28, Caa60 Bac29, Caa61 Bac30, Caa62 Bac31, Caa63 Bac33, Caa64 Bac34, Caa72 Bac35, Caa73 Bac36, Caa74 Bac37, Caa75 Bac39, Caa76 Bac41, Caa80 Bac42, Caa81 Bac43, Caa82 Bac45, Caa83 Bac46, Caa86 Bac47, Caa87 Bac48, Caa88 Bac50, Caa89 Bac51, Caa92 Bac52, Caa93 Bac55, Caa94 Bac56, Caa96 Bac57, Caa97 Bac60, Caa98 Bac61, Caaaa Condenser Line 1 Bac62, Caaab Bac65, Caaac Bac66, Caaae Bac67, Caaaf Bac70, Caaag Ebaa01 Bacbt, Daa21 Bacbu, Daa22 Bacbv, Daa23 Bacbw, Daa24 Bacbx, Daa25 Bacby, Daa26 Bacbz, Daa27 Bacca, Daa28 Baccb, Daa29 Baccc, Daa30 Baccd, Daa31 Bacce, Daa32 Baccf, Daa33 Baccg, Daa34 Bacch, Daa35 Bacci, Daa36 Description Line relay compressor 1 line 1 Partwinding/Star relay compressor 1 line 1 Delta relay compressor 1 line 1 Valve 1 compressor 1 line 1 Valve 2 compressor 1 line 1 Valve 3 compressor 1 line 1 Balancing valve compressor 1 line 1 Line relay compressor 2 line 1 Partwinding/Star relay compressor 2 line 1 Delta relay compressor 2 line 1 Valve 1 compressor 2 line 1 Valve 2 compressor 1 line 1 Valve 3 compressor 1 line 1 Balancing valve compressor 1 line 1 Line relay compressor 3 line 1 Partwinding/Star relay compressor 3 line 1 Delta relay compressor 3 line 1 Valve 1 compressor 3 line 1 Valve 2 compressor 3 line 1 Valve 3 compressor 3 line 1 Balancing valve compressor 3 line 1 Line relay compressor 4 line 1 Partwinding/Star relay compressor 4 line 1 Delta relay compressor 4 line 1 Valve 1 compressor 4 line 1 Valve 2 compressor 4 line 1 Valve 3 compressor 4 line 1 Balancing valve compressor 4 line 1 Line relay compressor 5 line 1 Partwinding/Star relay compressor 5 line 1 Delta relay compressor 5 line 1 Valve 1 compressor 5 line 1 Valve 2 compressor 5 line 1 Valve 3 compressor 5 line 1 Balancing valve compressor 5 line 1 Line relay, compressor 6 line 1 Partwinding/Star relay, compressor 6 line 1 Delta relay, compressor 6 line 1 Valve 1, compressor 6 line 1 Valve 2, compressor 6 line 1 Valve 3, compressor 6 line 1 Balancing valve, compressor 6 line 1 Line relay compressor 7 line 1 Partwinding/Star relay compressor 7 line 1 Delta relay compressor 7 line 1 Valve 1 compressor 7 line 1 Valve 2 compressor 7 line 1 Balancing valve compressor 7 line 1 Line relay compressor 8 line 1 Partwinding/Star relay compressor 8 line 1 Delta relay compressor 8 line 1 Valve 1 compressor 8 line 1 Valve 2 compressor 8 line 1 Balancing valve compressor 8 line 1 Line relay compressor 9 line 1 Partwinding/Star relay compressor 9 line 1 Delta relay compressor 9 line 1 Valve 1 compressor 9 line 1 Balancing valve compressor 9 line 1 Line relay compressor 10 line 1 Partwinding/Star relay compressor 10 line 1 Delta relay compressor 10 line 1 Valve 1 compressor 10 line 1 Balancing valve compressor 10 line 1 Relay line compressor 11 line 1 Partwinding/Star relay compressor 11 line 1 Delta relay compressor 11 line 1 Valve 1 compressor 11 line 1 Balancing valve compressor 11 line 1 Relay line compressor 12 line 1 Partwinding/Star relay compressor 12 line 1 Delta relay compressor 12 line 1 Valve 1 compressor 12 line 1 Balancing valve compressor 12 line 1 Subcooling valve line 1 Fan 1 line 1 Fan 2 line 1 Fan 3 line 1 Fan 4 line 1 Fan 5 line 1 Fan 6 line 1 Fan 7 line 1 Fan 8 line 1 Fan 9 line 1 Fan 10 line 1 Fan 11 line 1 Fan 12 line 1 Fan 13 line 1 Fan 14 line 1 Fan 15 line 1 Fan 16 line 1 Chan. 95 Logic Notes pRack +0300025EN rel. 1.5 - 17.02.2020 Other functions Line 1 ENG Mask Index Bacck, Eeaa03 Baccl, Egaa02 Bacdp, Eaaa11 Bacdq, Eaaa12 Bacdr, Eaaa13 Bacdv, Ecaa07, Edaa07 Bacdw, Ecaa08, Edaa08 Bacdx, Ecaa09, Edaa09 Bacdy, Ecaa10, Edaa10 Bacdz, Ecaa11, Edaa11 Bacea, Ecaa12, Edaa12 Bac01 Bacei Bacek, Ebaa01 Eaaa15 Eaaa16 Eaaa18 Eaaa19 Eaaa40 Eaaa41 Eaaa42 Eaaa43 Eaaa44 Eaaa45 Bac73, Cba08 Bac74, Cba09 Bac75, Cba10 Bac76, Cba11 Bac78, Cba12 Bac79, Cba22 Suction Line 2 Bac80, Cba23 Bac81, Cba24 Bac82, Cba25 Bac84, Cba26 Bac86, Cba35 Bac87, Cba36 Bac88, Cba37 Bac89, Cba38 Bac91, Cba39 Bac92, Cba47 Bac94, Cba48 Bac95, Cba49 Bac96, Cba50 Bac98, Cba51 Bacaa, Cba60 Bacab, Cba61 Bacac, Cba62 Bacad, Cba63 Bacaf, Cba64 Ebba01 Bacag, Cba72 Bacah, Cba73 Bacai, Cba74 Bacaj, Cba75 Bacal, Cba76 Bacan, Cba80 Suction Line 2 Bacao, Cba81 Bacap, Cba82 Bacar, Cba83 Bacas Cba86 Bacat, Cba87 Bacau, Cba88 Bacaw, Cba89 Bacax, Cba92 Bacay, Cba93 Bacbb, Cba94 Bacbc, Cba96 Bacbd, Cba97 Bacbg, Cba98 Bacbh, Cbaaa Bacbi, Cbaab Bacbl, Cbaac Bacbm, Cbaae Bacbn, Cbaaf Bacbq, Cbaag pRack +0300025EN rel. 1.5 - 17.02.2020 Description Heat recovery pump line 1 ChillBooster line 1 Oil pump 1 line 1 Oil pump 2 line 1 Oil fan line 1 Liquid injection valve/Economizer compressor 1 line 1 Liquid injection valve/Economizer compressor 2 line 1 Liquid injection valve/Economizer compressor 3 line 1 Liquid injection valve/Economizer compressor 4 line 1 Liquid injection valve/Economizer compressor 5 line 1 Liquid injection valve/ Economizer, compressor 6 line 1 Anti liquid return line 1 Force from BMS line 1 Subcooling line 1 Oil cooling pump screw compressor 1 line 1 Oil cooling fan screw compressor 1 line 1 Oil cooling pump screw compressor 2 line 1 Oil cooling fan screw compressor 2 line 1 Oil level valve compressor 1 line 1 Oil level valve compressor 2 line 1 Oil level valve compressor 3 line 1 Oil level valve compressor 4 line 1 Oil level valve compressor 5 line 1 Oil level valve, compressor 6 line 1 Relay line compressor 1 line 2 Partwinding/Star relay compressor 1 line 2 Delta relay compressor 1 line 2 Valve 1 compressor 1 line 2 Valve 2 compressor 1 line 2 Valve 3 compressor 1 line 2 Balancing valve compressor 1 line 2 Line relay compressor 2 line 2 Partwinding/Star relay compressor 2 line 2 Delta relay compressor 2 line 2 Valve 1 compressor 2 line 2 Valve 2 compressor 1 line 2 Valve 3 compressor 1 line 2 Balancing valve compressor 1 line 2 Line relay compressor 3 line 2 Partwinding/Star relay compressor 3 line 2 Delta relay compressor 3 line 2 Valve 1 compressor 3 line 2 Valve 2 compressor 3 line 2 Valve 3 compressor 3 line 2 Balancing valve compressor 3 line 2 Line relay compressor 4 line 2 Partwinding/Star relay compressor 4 line 2 Delta relay compressor 4 line 2 Valve 1 compressor 4 line 2 Valve 2 compressor 4 line 2 Valve 3 compressor 4 line 2 Balancing valve compressor 4 line 2 Line relay compressor 5 line 2 Partwinding/Star relay compressor 5 line 2 Delta relay compressor 5 line 2 Valve 1 compressor 5 line 2 Valve 2 compressor 5 line 2 Valve 3 compressor 5 line 2 Balancing valve compressor 5 line 2 Subcooling valve line 2 Line relay, compressor 6 line 2 Partwinding/Star relay, compressor 6 line 2 Delta relay, compressor 6 line 2 Valve 1 compressor 6 line 2 Valve 2 compressor 6 line 2 Valve 3 compressor 6 line 2 Balancing valve, compressor 6 line 2 Line relay compressor 7 line 2 Partwinding/Star relay compressor 7 line 2 Delta relay compressor 7 line 2 Valve 1 compressor 7 line 2 Valve 2 compressor 7 line 2 Balancing valve compressor 7 line 2 Line relay compressor 8 line 2 Partwinding/Star relay compressor 8 line 2 Delta relay compressor 8 line 2 Valve 1 compressor 8 line 2 Valve 2 compressor 8 line 2 Balancing valve compressor 8 line 2 Line relay compressor 9 line 2 Partwinding/Star relay compressor 9 line 2 Delta relay compressor 9 line 2 Valve 1 compressor 9 line 2 Balancing valve compressor 9 line 2 Line relay compressor 10 line 2 Partwinding/Star relay compressor 10 line 2 Delta relay compressor 10 line 2 Valve 1 compressor 10 line 2 Balancing valve compressor 10 line 2 Line relay compressor 11 line 2 Partwinding/Star relay compressor 11 line 2 Delta relay compressor 11 line 2 Valve 1 compressor 11 line 2 Balancing valve compressor 11 line 2 Line relay compressor 12 line 2 Partwinding/Star relay compressor 12 line 2 Delta relay compressor 12 line 2 Valve 1 compressor 12 line 2 Balancing valve compressor 12 line 2 96 Chan. Logic Notes Common Other functions Line 2 Condenser ENG Mask Index Baccn, Dba20 Bacco, Dba21 Baccp, Dba22 Baccq, Dba23 Baccr, Dba24 Baccs, Dba25 Bacct, Dba26 Baccu, Dba27 Baccv, Dba28 Baccw, Dba29 Baccx, Dba30 Baccy, Dba31 Baccz, Dba32 Bacda, Dba33 Bacdb, Dba34 Bacdc, Dba35 Bacdd, Dba36 Bacde, Eeba03 Bacdf, Egba02 Bacds, Eaba10 Bacdt, Eaba11 Bacdu, Eaba12 Baceb, Ecba07, Edba07 Bacec, Ebca08, Edba08 Baced, Ecba09, Edba09 Bacee, Ecba10, Edba10 Bacef, Ecba11, Edba11 Baceg, Ecba12, Edba12 Bac72 Bacej Bacel, Ebbb01 Eaba40 Eaba41 Eaba42 Eaba43 Eaba44 Eaba45 Bacdg, Efe21 Bacdh, Efe22 Bacdi, Efe23 Bacdj, Efe24 Bacdk, Efe25 Bacdl Bacdm, Efe26 Bacdn, Efe27 Bacdo, Efe28 Baceh Bacem Bacen Description Fan1 line 2 Fan 2 line 2 Fan 3 line 2 Fan 4 line 2 Fan 5 line 2 Fan 6 line 2 Fan 7 line 2 Fan 8 line 2 Fan 9 line 2 Fan 10 line 2 Fan 11 line 2 Fan 12 line 2 Fan 13 line 2 Fan 14 line 2 Fan 15 line 2 Fan 16 line 2 Fan inverter line 2 Heat recovery pump line 2 ChillBooster line 2 Oil pump 1 line 2 Oil pump 2 line 2 Oil fan line 2 Liquid injection valve compressor 1 line 2 Liquid injection valve compressor 2 line 2 Liquid injection valve compressor 3 line 2 Liquid injection valve compressor 4 line 2 Liquid injection valve compressor 5 line 2 Liquid injection valve compressor 6 line 2 Anti liquid return line 2 Force from BMS line 2 Subcooling line 2 Oil level valve compressor 1 line 2 Oil level valve compressor 2 line 2 Oil level valve compressor 3 line 2 Oil level valve compressor 4 line 2 Oil level valve compressor 5 line 2 Oil level valve, compressor 6 line 2 Generic stage function 1 Generic stage function 2 Generic stage function 3 Generic stage function 4 Generic stage function 5 Active alarms Generic alarm function 1 Generic alarm function 2 Generic scheduling function Sign of life Minor alarm Serious alarm Chan. Logic Notes Tab. A.g 97 pRack +0300025EN rel. 1.5 - 17.02.2020 ENG Common Other Line 2 C. Suct. Other functions C. Suct. Analogue inputs Mask Index Bab01, Caaal Bab02, Caaam Bab03, Caaao Bab04, Daa39 Bab09, Daa40 Bab11, Daa41 Bab12 Bab13, Eeaa05 Bab15, Daa20 Bab16 Bab17, Eaaa04 Bab29, Ecaa01, Edaa01 Bab30, Ecaa02 Edaa02 Bab31, Ecaa03, Edaa03 Bab32, Ecaa04, Edaa04 Bab33, Ecaa05, Edaa05 Bab34, Ecaa06, Edaa06 Bab41, Eaaa05 Bab42, Eaaa06 Bab43, Eaaa07 Bab44, Eaaa08 Bab45, Eaaa09 Bab46, Eaaa10 Bab05, Caal Bab06, Caaam Bab07, Caaao Bab08, Dba39 Bab10, Dba40 Bab48, Dba38 Bab49 Bab14, Eeba05 Bab18, Eaba04 Bab35, Ecba01, Edba01 Bab36, Ecba02, Edba02 Bab37, Ecba03, Edba03 Bab38, Ecba04, Edba04 Bab39, Ecba05, Edba05 Bab40, Ecba06, Edba06 Bab47, Eaba05 Bab19, Efe06 Bab20, Efe07 Bab21, Efe08 Bab22, Efe09 Bab23, Efe10 Bab24, Efe11 Bab25, Efe12 Bab26, Efe13 Bab27, Efe14 Bab28, Efe15 Bab58 Description Return pressure probe line 1 Return backup pressure probe line 1 Return temperature probe line 1 Condensing pressure probe line 1 Backup condensing pressure probe line 1 Discharge temperature probe line 1 Liquid temperature probe line 1 Heat recovery outlet temperature probe line 1 Outside temperature probe line 1 Room temperature probe line 1 Oil temperature probe line 1 Discharge temperature probe compressor 1 line 1 Discharge temperature probe compressor 2 line 1 Discharge temperature probe compressor 3 line 1 Discharge temperature probe compressor 4 line 1 Discharge temperature probe compressor 5 line 1 Discharge temperature probe, compressor 6 line 1 Oil temperature probe compressor 1 line 1 Oil temperature probe compressor 2 line 1 Oil temperature probe compressor 3 line 1 Oil temperature probe compressor 4 line 1 Oil temperature probe compressor 5 line 1 Oil temperature probe compressor 6 line 1 Return pressure probe line 2 Return backup pressure probe line 2 Return temperature probe line 2 Condensing pressure probe line 2 Backup condensing pressure probe line 2 Discharge temperature probe line 2 Liquid temperature probe line 2 Heat recovery outlet temperature probe line 2 Oil temperature probe line 2 Discharge temperature probe compressor 1 line 2 Discharge temperature probe compressor 2 line 2 Discharge temperature probe compressor 3 line 2 Discharge temperature probe compressor 4 line 2 Discharge temperature probe compressor 5 line 2 Discharge temperature probe, compressor 6 line 2 Oil temperature probe compressor 1 line 2 Generic active probe A Generic passive probe A Generic active probe B Generic passive probe B Generic active probe C Generic passive probe C Generic active probe D Generic passive probe D Generic active probe E Generic passive probe E Energy meter Chan. Logic Notes Chan. Logic Notes Tab. A.h Line 2 Line 1 Analogue outputs Mask Index Bad01, Caa14 Bad02, Eaaa14 Bad07, Daa38 Bad08, Eeaa04 Bad12, Efe29 Eaaa17 Bad04 Bad05, Eaba13 Bad10, Dba37 Bad11, Eeba04 Bad13, Efe30 Eaaa20 Description Compressor inverter output line 1 Oil pump output line 1 Fan inverter output line 1 Heat recovery valve output line 1 Generic modulating output 1 Oil cooling pump output screw compressor 1 Compressor inverter output line 2 Oil pump output line 2 Fan inverter output line 2 Heat recovery valve output line 2 Generic modulating output 2 Oil cooling pump output screw compressor 2 Tab. A.i CAREL reserves the right to modify or change its products without prior warning. pRack +0300025EN rel. 1.5 - 17.02.2020 98 pRack +0300025EN rel. 1.5 - 17.02.2020 CAREL INDUSTRIES - Headquarters Via dell’Industria, 11 - 35020 Brugine - Padova (Italy) Tel. (+39) 049.9716611 - Fax (+39) 049.9716600 e-mail: [email protected] - www.carel.com ">
Advertisement
Key Features
- Compressor Rack Control
- Inverter Management
- Scheduling Capabilities
- Alarm Management
- Built-in Display
- Multiple Languages
Frequently Answers and Questions
What types of compressors can the Carel 2750441 control?
It manages scroll, reciprocating, digital scroll, and screw compressors.
Does the device have a display?
Yes, the PRK300S3FK model has a built-in display (PGD1, 132x64 pixel). Other models may have an external display option.
What communication interfaces are available?
It includes an integrated RS485 serial interface and a USB port.
What are the operating temperature ranges?
The operating temperature ranges vary depending on the model and whether an Ultracap module is installed. Refer to the manual's 'Technical Specifications' section for precise details.
How many compressors can it handle?
It can manage up to 12 scroll or piston compressors per line, with a maximum of 2 screw compressors on line 1, and up to 16 fans per line. Refer to the manual for specific configurations.