Sunlover Heating SL8 RRT swimming pool controller Instructions
Below you will find brief information for swimming pool controller SL8 RRT. This device will heat your swimming pool using solar energy and optional auxiliary heater (gas or heat pump). The SL8 RRT is designed to eliminate the need for a temperature sensor cable running from the solar controller to the roof, instead it uses a Solar Powered roof temperature transmitter that only transmits when the sun is out. It automatically switches on/off the auxiliary heater to maintain pool temperature, and can be manually controlled as well.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
SL8 RRT – INSTRUCTIONS Page 1 of 5
DESCRIPTION:
The SL8 RRT is a swimming pool controller that heats a swimming pool by the use of solar panels or an auxiliary heater (if fitted).
The auxiliary heater (gas or heat pump) has a temperature limit setting (aux limit), the pool will be heated to this limit by the auxiliary heater.
The auxiliary heater run time is controlled by heat demand settings, which can be set to on/off and set to run between start and end times, note that if the start & end time are set to the same values the auxiliary heater will run for 24 hours to achieve temperature limit.
If solar gain is available the solar system will heat the pool to the solar limit (sol limit), if large solar gain is detected the auxiliary heater will be switched off to save energy. Solar has a time lockout that prevents heating outside of the time set (default 09:00 – 18:00). If the system is fitted with an Auto
Divert Valve it will turn when there is solar gain and switch on the booster pump if fitted.
This unit has been designed to eliminate the need to run a temperature sensor cable from the solar controller to the roof, this is replaced by a Solar Powered roof temperature transmitter that only transmits when the sun is out, and a receiver that calculates the roof and pool temperature turning on the solar booster pump when required. The temperature sensors used with this unit are digital thermostats and require no calibration.
SETTINGS MENU
To enter the SETTINGS MENU push either the up or down buttons and the following will be displayed;
SETTINGS MENU
1) MANUAL MODE
Use Up/Down buttons to scroll to the option you wish to change. Press the Enter button to select the currently displayed menu item.
All menu items are shown below;
SETTINGS MENU
1) MANUAL MODE
2) FILTER TIMER
3) TEMPERATURE
4) HEAT DEMAND
5) MODE
6) CLOCK (24h)
7) SAVE & EXIT
1) MANUAL MODE
MANUAL PUMP MODE
UP=ON DOWN=OFF
MANUAL MODE allows you to manually set the aux pump to ‘on’ by pressing the Up button or ‘off’ by pressing the Down button.
Pressing Enter will return you to the SETTINGS MENU. You can also keep pressing Enter to toggle the filter pump from ‘on’ to ‘off’ and vice versa.
MANUAL MODE will time out, after 24 hours the SL8 will return to normal operation.
SL8 RRT – INSTRUCTIONS Page 2 of 5
2) FILTER TIMER
FILTER TIMER
(ON or OFF/V7STD)
FILTER TIMER can be set to ON or OFF/V7STD, this controls the power out of the left hand socket, if
OFF/V7STD is selected the left hand socket will be permanently powered and the right hand socket will control the solar pump, when the FILTER TIMER is set to ON the left hand power socket runs a filter pump on a timer with the following settings;
SINGLE CYCLE
DUAL CYCLE
Single cycle sub menu
SINGLE CYCLE
START TIME X:XX
Dual cycle sub menus
FIRST CYCLE FIRST CYCLE
START TIME X:XX
SINGLE CYCLE
END TIME X:XX
END TIME X:XX
SECOND CYCLE SECOND CYCLE
START TIME X:XX END TIME X:XX
When you enter the FILTER SETUP menu you will need to select SINGLE CYCLE or DUAL CYCLE, the selected option will be flashing, you can use the Up/Down buttons to change to the selected option, once you select the required cycle by pressing Select you will be prompted to set the cycle START
TIME and END TIME, modify these by pressing the Up/Down buttons, press Select to accept the setting.
SINGLE CYCLE will run the filter pump once per day. DUAL CYCLE will run the filter pump twice per day. Note that if you overlap the 2 cycle times you effectively end up with a single cycle.
Factory Default is ON, DUAL CYCLE from 09:00 to 13:00 and 16:00 to 20:00
NOTE: Note that the maximum combined rated current is 10 Amps (2400W at 240VAC.)
3) TEMPERATURE
TEMPERATURE
SOL LIMIT XX.X°
When you enter the TEMPERATURE menu you may change the solar heater temperature limit setting
(SOL LIMIT) by pressing the Up/Down buttons, if no change is required simply push Enter.
Factory default is for SOL LIMIT is 30°C.
TEMPERATURE
AUX LIMIT XX.X°
AUX LIMIT sets the temperature the auxiliary heater will heat the swimming pool to you can use
Up/Down to change the selected temperature, press Enter to accept. (default is 25°C)
NOTE 1: AUX LIMIT setting will only be shown if heat demand is turned on.
NOTE 2: For maximum efficiency it is advisable that the solar limit (SOL LIMIT) be set higher than the auxiliary limit (AUX LIMIT)
SL8 RRT – INSTRUCTIONS Page 3 of 5
4) HEAT DEMAND (only set ON if auxiliary heating fitted)
HEAT DEMAND
ON/OFF
When you enter the HEAT DEMAND you will need to select ON or OFF, the selected option will be flashing, you can use Up/Down to change the selected option, Enter to accept.
If OFF is selected you will return to the menu, If ON is selected you will be prompted for START and
END time, modify values by using the Up/Down buttons, use Enter to accept the values. Factory default is ‘heat demand off’
HEAT DEMAND TIME
START TIME X:XX
HEAT DEMAND TIME
END TIME X:XX
NOTE: if a 24 hour continuous run time is required then set the start time and end time to the same value. (e.g. Start 12:00, End 12:00)
IF LIMIT ACTIVE
SAMPLE AT XXXX
Sets the sampling period once the pool has reached the auxiliary temperature limit, options are 15 min, 30 min, 1 hour, 2 hours. Once the pool reaches the aux temperature limit and the filter pump is turned off it will not be turned on until the sample period expires, the filter pump will then run for a minimum period of 3 mins so that water can flow past the pool temperature sensor and obtain an accurate reading. Should heating be required the filter pump will remain on to heat the pool.
Factory default for HEAT DEMAND is OFF (06:00 to 22:00, sample @ 1 hour)
5) MODE
MODE
SUMMER MODE/WINTER MODE/TROPICAL MODE
You can use Up/Down to change the selected option, Enter to accept.
SUMMER MODE is the normal operation of heating the swimming pool.
TROPICAL MODE is selected if you wish to cool the swimming pool, the solar pump will run if the roof temperature is colder than the pool until SOL LIMIT is obtained; note that this is most likely to occur at night.
WINTER MODE, when selected you will be prompted to select the start month and end month of winter
(inclusive), this assists in the systems off-season maintenance and save energy as solar gain may be available but swimming temperature cannot be achieved. If heat demand is set to OFF a 3 minute flush of the solar matting occurs between 10:00 and 16:00 providing the roof temperature is equal or greater than the pool, but if that condition does not occur a solar system flush will be forced to occur at 16:00.
If heat demand is ON the system operates similar to normal mode but solar pump activity is monitored and will force a 3 minute flush if solar has not been active for seven days, note the unit may flush if winter mode is selected on the day of install.
6) CLOCK (24h)
TO CHANGE CLOCK TO CHANGE CLOCK TO CHANGE CLOCK TO CHANGE CLOCK
SET MINS XX SET HOURS XX SET DATE XX SET MONTH XX
When you enter the CLOCK menu you will be prompted to change the MINS settings, adjust minutes by pressing the Up/Down buttons, to accept the setting press the Enter button.
You will then be prompted to change the HOURS, adjust by pressing the Up/Down buttons, to accept the setting press the Enter button.
You will then be prompted to change the DATE, adjust by pressing the Up/Down buttons, to accept the setting press the Enter button.
You will then be prompted to change the MONTH, adjust by pressing the Up/Down buttons, to accept the setting press the Enter button.
SL8 RRT – INSTRUCTIONS Page 4 of 5
7) SAVE & EXIT
When this menu is selected, push Enter to save ALL settings, the unit will return to normal operation automatically.
Note: If any of the menu items are left unattended for 3-4 mins the menu will time out and automatically save all settings and return to operation.
The Enter button.
FOR MANUAL MODE
PRESS ENTER NOW
Pressing the Enter button once will display the above message for ~3 seconds, simply wait and the unit will return to normal operation.
If you Enter is pressed for a second time within a 3 second period, the display will indicate you have entered Manual mode, operation is the same as manual mode in the menu with the only difference being the timeout value is 4 Hours.
NOTES.
1.
2.
3.
If a sensor fault is detected the SL8 will display which sensor and what the fault is.
Should power be interrupted for any reason, the SL8 will resume normal operation when power is restored, all information will have been kept.
Temperature sensors used with this unit are Digital and are accurate to 0.5 Deg. C, no calibration
4.
5.
6. is required.
The sensor cable with the thin trace is the positive and is usually fitted to the right hand side of the green plug, incorrect polarity will be displayed.
If Auxiliary heater interlock switching is used the maximum load is 5A at 32VAC max.
Solar start and end times may be changed by holding the up button while power is applied.
Return to Manufacturer for repair.
Installation Notes
As the unit operates in a UHF radio band, reflections and moving objects can cause a transmission to be corrupted with a subsequent indication “MISSED RECEPTION” on the display. Up to 10 transmissions can be missed before pump action will occur and the solar pump will turn off. If this occurs, and if the solar conditions are still favorable, the solar pump will not turn on again and resume normal operation unless it has received a valid transmission.
The remote roof transceiver obtains its operating power from a solar panel, it will not operate if there is no sun or if there is significant cloud cover. Obviously solar heating would not occur in such conditions.
Due to the possibility of reception ghosting and electrical interference the Transmitter may be required to be moved to an alternative position, this may be as little as two meters and keep in mind that the roof sensor cable may be extended 20 meters if required. The main controller should be mounted away from other electrical appliances as far as possible to reduce the chance of interference.
If the unit is to be installed in a metal shed there may be reception issues and the controller may need to be optioned with a remote antenna or moved outside.
A Power substitute cable is supplied for installation testing on cloudy days – Simply clip a 9Volt
Transistor Battery onto the Battery Snap supplied and substitute the left hand green plug marked PV.
Remember to refit original plug when testing is over.
SL8 RRT – INSTRUCTIONS Page 5 of 5
WARRANTY
This product is covered by a limited 3 year warranty against component failure or faulty workmanship from the date of installation.
A faulty unit should be returned in the first instance to the dealer from which the unit was purchased.
Damage to the unit due to misuse, power surges, lightning strikes or installation that is not in accordance with the manufacturer’s instruction may void the warranty.
Warranty does not cover travel costs to or from installation site. Unit must be returned to manufacturer for repairs.
If the power cord is damaged, do not use the controller; return the unit to the supplier for repair.
Customer Record. (To be retained by the customer);
Dealer/Installer Name
Serial Number
___________________________
___________________________
Date Installed
For service assistance phone SUNLOVER HEATING
VIC 03 9887 2131
NSW 02 9838 0000
QLD 07 5597 7360
___________________________
62 Parkhurst Drive,
Knoxfield 3153
Victoria Australia
Unit 2
20-22 Foundry Road,
Factory 6
7-9 Activity Crescent,
Molendinar 4214
Queensland Australia
Seven Hills 2147
NSW Australia
www.sunloverheating.com.au
advertisement
Key Features
- Solar heating
- Auxiliary heater (gas/heat pump)
- Automatic temperature control
- Manual pump control
- Solar Powered roof temperature transmitter
- Digital temperature sensors
- Filter timer
- Summer/Winter/Tropical mode
- Clock setting
- Save & Exit