Siemens Milltronics MSI, MMI Belt scales Operating Instructions

Siemens Milltronics MSI, MMI Belt scales Operating Instructions

Milltronics MSI and Milltronics MMI belt scales are heavy-duty, high-accuracy single and multiple idler scales for process and loadout control. The scales are designed to be inserted into belt conveyors for continuous weighing of dry bulk solids.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Siemens Milltronics MSI & MMI Belt Scales Operating Instructions | Manualzz
Belt Scales
Milltronics MSI and MMI
Operating Instructions 06/2012
Milltronics
Safety Guidelines
Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
equipment. These warning notices are accompanied by a clarification of the level of caution to be observed.
Qualified Personnel
This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install
and operate this equipment in accordance with established safety practices and standards.
Unit Repair and Excluded Liability:




The user is responsible for all changes and repairs made to the device by the user or the user’s agent.
All new components are to be provided by Siemens Milltronics Process Instruments.
Restrict repair to faulty components only.
Do not reuse faulty components.
Warning: Cardboard shipping package provides limited humidity and moisture protection. This product can only function properly
and safely if it is correctly transported, stored, installed, set up, operated, and maintained.
This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to
several frequency based communications.
Note: Always use product in accordance with specifications.
Copyright Siemens AG 2012. All Rights Reserved
Disclaimer of Liability
This document is available in bound version and in
electronic version. We encourage users to purchase
authorized bound manuals, or to view electronic versions as
designed and authored by Siemens Milltronics Process
Instruments. Siemens Milltronics Process Instruments will
not be responsible for the contents of partial or whole
reproductions of either bound or electronic versions.
While we have verified the contents of this
manual for agreement with the instrumentation
described, variations remain possible. Thus we
cannot guarantee full agreement. The contents of
this manual are regularly reviewed and
corrections are included in subsequent editions.
We welcome all suggestions for improvement.
Technical data subject to change.
MILLTRONICS®is a registered trademark of Siemens Milltronics Process Instruments.
Contact SMPI Technical Publications
at the following address:
European Authorized Representative
Technical Publications
Siemens AG
Siemens Milltronics Process Instruments
1954 Technology Drive, P.O. Box 4225
Peterborough, Ontario, Canada, K9J 7B1
Email: [email protected]
Siemens AG
Industry Sector
76181 Karlsruhe
Deutschland


For a selection of Siemens Milltronics level measurement manuals, go to:
www. siemens.com/processautomation. Under Process Instrumentation, select Level Measurement and then go to the manual
archive listed under the product family.
For a selection of Siemens Milltronics weighing manuals, go to:
www. siemens.com/processautomation. Under Weighing Technology, select Continuous Weighing Systems and then go to the
manual archive listed under the product family.
© Siemens AG 2012
Milltronics MSI and MMI
1
___________________
Introduction
2
___________________
Safety notes
Milltronics
Belt Scales
Milltronics MSI and MMI
3
___________________
Description
4
___________________
Installing/Mounting
5
___________________
Connecting
6
___________________
Commissioning
Operating Instructions
7
___________________
Service and maintenance
8
___________________
Technical data
9
___________________
Dimension drawings
06/2012
7ML19985CY04-04
Legal information
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.
CAUTION
without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.
NOTICE
indicates that an unintended result or situation can occur if the relevant information is not taken into account.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Industry Sector
Postfach 48 48
90026 NÜRNBERG
GERMANY
Order number: 7ML19985CY0
Ⓟ 07/2012 Technical data subject to change
Copyright © Siemens AG 2012.
All rights reserved
Table of contents
1
Introduction................................................................................................................................................ 5
1.1
2
The manual ....................................................................................................................................5
Safety notes............................................................................................................................................... 7
2.1
General safety instructions ............................................................................................................7
2.2
Installation in hazardous areas ......................................................................................................7
3
Description............................................................................................................................................... 11
4
Installing/Mounting................................................................................................................................... 13
5
4.1
Introduction ..................................................................................................................................13
4.2
4.2.1
4.2.2
4.2.3
4.2.4
4.2.5
4.2.6
4.2.7
4.2.8
Conveyor considerations .............................................................................................................13
Control gates................................................................................................................................14
Conveyor belting ..........................................................................................................................14
Head pulley ..................................................................................................................................14
Conveyor curvature......................................................................................................................17
Belt ploughs .................................................................................................................................18
Stacker conveyors .......................................................................................................................18
Conveyor trippers.........................................................................................................................18
Skirt boards and sealing strips.....................................................................................................19
4.3
4.3.1
4.3.2
4.3.3
4.3.4
4.3.5
4.3.6
4.3.7
4.3.8
Installation procedure...................................................................................................................21
Remove the idler..........................................................................................................................22
Remove the idler foot plate and modify the idler frame at both ends ..........................................23
Idler mounting: .............................................................................................................................23
Position the weighbridge..............................................................................................................27
Position the scale.........................................................................................................................27
Release the shipping stops..........................................................................................................28
Align and level the idlers ..............................................................................................................28
Check alignment ..........................................................................................................................29
Connecting .............................................................................................................................................. 33
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
3
Table of contents
6
7
8
Commissioning ........................................................................................................................................ 35
6.1
Calibration ................................................................................................................................... 35
6.2
Test Load .................................................................................................................................... 35
6.3
Balancing..................................................................................................................................... 35
6.4
Final calibration ........................................................................................................................... 36
6.5
Zero calibration ........................................................................................................................... 36
6.6
Span calibration .......................................................................................................................... 36
6.7
Material test................................................................................................................................. 37
6.8
Re-rating...................................................................................................................................... 37
Service and maintenance ........................................................................................................................ 39
7.1
Maintenance................................................................................................................................ 39
7.2
Replacing a load cell ................................................................................................................... 40
7.3
Spare parts.................................................................................................................................. 40
7.4
Technical support........................................................................................................................ 41
Technical data ......................................................................................................................................... 43
8.1
9
Metrological characteristics......................................................................................................... 46
Dimension drawings ................................................................................................................................ 49
9.1
Outline dimensions...................................................................................................................... 49
Milltronics MSI and MMI
4
Operating Instructions, 06/2012, 7ML19985CY04-04
Introduction
1
Note
The Siemens weighing system is to be used only in the manner outlined in this manual,
otherwise protection provided by equipment may be impaired.
 It is your responsibility to read this manual before installing and starting up any
component of the weighing system to which the belt scale is being applied.
1.1
The manual
This manual covers only belt scale installation, operation, and maintenance procedures.
Integrator and speed sensor operating instructions are available for download from our website:
Siemens weighing (http://www.siemens.com/weighing)
Follow these operating instructions for quick, trouble-free installation, and maximum accuracy
and reliability of your weighing system.
We always welcome suggestions and comments about manual content, design, and
accessibility. Please direct your comments to:
Technical publications (mailto:[email protected])
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
5
Introduction
1.1 The manual
Milltronics MSI and MMI
6
Operating Instructions, 06/2012, 7ML19985CY04-04
2
Safety notes
2.1
General safety instructions
CAUTION
Correct, reliable operation of the product requires proper transport, storage, positioning and
assembly as well as careful operation and maintenance. Only qualified personnel should
install or operate this instrument.
Note
Alterations to the product, including opening or improper repairs of the product, are not
permitted.
If this requirement is not observed, the CE mark and the manufacturer's warranty will expire.
2.2
Installation in hazardous areas
WARNING
Equipment used in hazardous areas must be Ex-approved and marked accordingly. It is
required that the special conditions for safe use provided in the manual and in the Ex
certificate are followed!
Hazardous area approvals
Note
The nameplate shown is a typical example. Please check the nameplate on your device for
your specific device configuration.
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
7
Safety notes
2.2 Installation in hazardous areas
Nameplate
MILLTRONICS MSI BELT SCALE
7ML1234-56789-0ABC-D
Serial No.: GYZ / S1234567
Input : 15 V
Max.
Enclosure : IP65
Ambient Temp. : ñ 40 C to +75 C
N117
0518
R
Class II, Div 1, Gr. E, F, G
Class III
IEC Ex SIR 08.0071X
Ex tD A21 IP65 T90 C
II 2 D
Ex tD A21 IP65 T90 C
SIRA 06ATEX9305X
Do Not Disassemble When An Explosive Dust Atmosphere Is Present
Siemens Milltronics Process Instruments Inc., Peterborough
Made in Canada
The device is approved for use in hazardous area and has the following approval:
● II 2D Ex tD A21 IP65 T90ºC
WARNING
Make sure the hazardous area approval is suitable for the environment in which the
device will be installed.
Milltronics MSI and MMI
8
Operating Instructions, 06/2012, 7ML19985CY04-04
Safety notes
2.2 Installation in hazardous areas
Instructions specific to hazardous area installations
(Reference European ATEX Directive 94/9/EC, Annex II, 1/0/6)
The following instructions apply to equipment covered by certificate number
SIRA06ATEX9305X:
1. For use and assembly, refer to the main instructions.
2. The equipment is certified for use as Category 2D equipment and may be used in hazardous
zones 21 and 22 with dusts.
3. This equipment has a maximum surface temperature of T90 °C (in a 75 °C ambient). Refer to
the applicable code of practice for selection of this equipment with respect to specific dust
ignition temperatures.
4. The equipment is certified for use in an ambient temperature range of -40 °C to 75 °C.
5. If the conductors of the attached cable are terminated in the hazardous area, appropriate
explosion protection (’Ex’) methods should be used that meet the requirements of European
Directive 94/9/EC for Group II, Category 2D.
6. The equipment has not been assessed as a safety related device (as referred to by Directive
94/9/EC Annex II, clause 1.5).
7. Installation and inspection of this equipment shall be carried out by suitably trained personnel
in accordance with the applicable code of practice.
8. Repair of this equipment shall be carried out by suitably trained personnel in accordance with
the applicable code of practice.
9. Components to be incorporated into or used as replacements in the equipment shall be fitted
by suitably trained personnel in accordance with the manufacturer’s documentation.
10.If the equipment is likely to come into contact with aggressive substances, then it is the
responsibility of the user to take suitable precautions that prevent it from being adversely
affected, thus ensuring that the type of protection is not compromised.
Aggressive substances: e.g. acidic liquids or gases that may attack metals or solvents that
may affect polymeric materials.
Suitable precautions: e.g. regular checks as part of routine inspections or establishing from
the material’s data sheet that it is resistant to specific chemicals
11.Product marking shall include the warning: Do not disassemble when an explosive dust
atmosphere is present.
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
9
Safety notes
2.2 Installation in hazardous areas
Special conditions for safe use
The ’X’ suffix to the certificate number relates to the following special condition(s) for safe use:
● The equipment shall be installed such that the supply cable is protected from mechanical
damage. The cable shall not be subjected to tension or torque. If the cable is to be
terminated within an explosive atmosphere, then appropriate protection of the free end of the
cable shall be provided.
● The equipment shall be bonded to earth by the use of approved type metal conduit and
conduit fittings.
● The apparatus shall be supplied with an input voltage not exceeding 15V.
● This assessment does not cover any additional mechanical parts (e.g. conveyor belt, idlers)
that are added during installation which may require an ignition hazard assessment as
specified in EN 13463-1:2001 Annex B.
Milltronics MSI and MMI
10
Operating Instructions, 06/2012, 7ML19985CY04-04
Description
3
Milltronics MSI and MMI belt scales
Milltronics MSI belt scale is a heavy-duty, high-accuracy single idler scale for process and loadout control.
Milltronics MMI belt scale is a heavy-duty, high-accuracy multiple idler scale for critical process
and load-out control. The MMI uses two or more Milltronics MSI belt scales in succession. The
scales are designed to be inserted into belt conveyors for continuous weighing of dry bulk solids.
Each MSI includes:
● one weighbridge with two load cells
● Siemens Milltronics test weight(s), ordered separately
The addition of an idler (supplied and installed by the customer) to the weighbridge completes
the weighing assembly. The load cells provide an electronic signal, proportional to load, which is
fed to the Siemens integrator. Thus, weighing is accomplished without interrupting the process
and without affecting the process material.
The MMI is used where conveyor belt speeds or belt loading characteristics result in conditions
that necessitate extending the weighing time beyond the capabilities of a single idler scale. It is
also well suited for applications that require higher sustained accuracies, such as production
control, inventory accountability or where certification for trade purposes is required.
The MSI/MMI is an accurate and repeatable force sensor. Its performance is ultimately
dependent upon the conveyor system and the quality of the installation and alignment.
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
11
Description
①
②
③
④
⑤
⑥
⑦
idler mount bracket
test weight bar
idler clip
idler frame
scale mounting bracket
dynamic beam
static beam
Figure 3-1
Overview of belt scale system
Note
Conduit and cable arrangement may differ from example shown
Principle of operation
Belt scales work with an existing belt conveyor and the selected Siemens integrator. As material
moving along the conveyor belt travels over the belt scale, it exerts a force proportional to the
material load through the suspended idler to the load cells.
The belt scale reacts only to the vertical component of the applied force. The resulting
movement in each load cell is sensed by its strain gauges. When the strain gauges are excited
by voltage from the electronic integrator, they produce an electrical signal proportional to weight,
which is then returned to the integrator. The vertical movement of the load cells is limited by the
positive overload stop incorporated into the load cell design.
Milltronics MSI and MMI
12
Operating Instructions, 06/2012, 7ML19985CY04-04
Installing/Mounting
4.1
4
Introduction
CAUTION
Installation shall be performed only by qualified personnel in accordance with local
governing regulations.
The belt scale is shipped from the factory as a single unit packed in a container for protection.
The weighbridge must be removed from its package and inspected for physical damage. Be sure
the conveyor design meets the installation requirements for the belt scale.
Note
 Use only approved conduit and conduit fittings or cable glands to maintain NEMA or IP
rating, as applicable.
 For hazardous area installations, use only approved junction boxes, metal conduit and
conduit fittings or cable glands. Adapter supplied for ½" NPT to M20x1.5. Discard if using
½" NPT conduit fitting.
 Adjust conveyor stringers to be rigid, straight, parallel to, and square with the belt line in
the area of the scale installation.
 Adjust pulleys to ensure that the conveyor belt tracks straight and centrally from the head
to the tail pulley.
 The idler to be used on the scale and at least the next two approach and retreat idlers,
must be of the same style and manufacturer, and in good condition.
Prepare the site in accordance with the Siemens drawing(s) or by referring to the Belt Scale
Applications Guidelines (7ML19985GA01).
4.2
Conveyor considerations
The ideal placement of the belt scale depends on the conveyor system. This section provides
guidelines to determine belt scale placement.
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
13
Installing/Mounting
4.2 Conveyor considerations
4.2.1
Control gates
The installation of a material feed control gate or similar device improves uniform flow of
material.
①
②
③
Control gate
Uniform material distribution
Belt scale
Note
Ensure steady and uniform material loading to the belt at or near the same speed as the
conveyor belt.
4.2.2
Conveyor belting
Variations in the number of belt plies, the cover thickness and the type and number of splices in
a given belt cause considerable change in the weight per unit length of the belt. During the
course of zero calibrations, belt scales average the weight of the belt over one complete circuit
of the belt. Large deviations from the average adversely affect the zero calibrations.
4.2.3
Head pulley
Note
Use caution when installing a scale in a short conveyor, or when locating the scale near the
head pulley.
Since head pulleys are flat faced, and carrying idlers are generally troughed, the belt profile must
change from troughed to flat in a short distance. To accommodate this, the conveyor
manufacturer designs a built-in vertical displacement of the head pulley above the top of the
center roll of the adjacent idler.
Milltronics MSI and MMI
14
Operating Instructions, 06/2012, 7ML19985CY04-04
Installing/Mounting
4.2 Conveyor considerations
● Insert idlers of decreasing trough angles between the head pulley and the normal run of
idlers or there will be a considerable amount of stress on the belt edges and the idlers
adjacent to the head pulley. The stress is transmitted to the scale.
Note
On conveyors with 20° trough idlers throughout, a minimum of two fixed 20° idlers must
be located between the scale idler and the head pulley.
①
②
③
④
20º idlers
Minimum 3 idler spaces
Head pulley
Belt scale
Note
On conveyors with 35° trough idlers throughout, a minimum of two 35° and one 20°
retreat idlers must be located between the scale and the head pulley.
①
②
③
④
⑤
⑥
35º idlers
Minimum 4 idler spaces
Head pulley
20º idler
35º idlers
Belt scale
Note
On conveyors with 45° trough idlers throughout, a minimum of two 45°, one 35°, and one
20° retreat idlers must be located between the scale and the head pulley.
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
15
Installing/Mounting
4.2 Conveyor considerations
7
①
②
③
④
⑤
⑥
⑦
45º idlers
Minimum 5 idler spaces
Head pulley
20º idler
35º idler
45º idlers
Belt scale
Note
The vertical displacement of the head pulley relative to the adjacent retreat idler is
normally in excess of that which is acceptable for belt scale installations.
When locating the scale close to the head pulley, a maximum of 13 mm (½") vertical
displacement between the top of the head pulley and the top of the center of the adjacent
roll is allowed.
①
②
③
13 mm (1/2") maximum
Head pulley
20° idler, center roll
Milltronics MSI and MMI
16
Operating Instructions, 06/2012, 7ML19985CY04-04
Installing/Mounting
4.2 Conveyor considerations
4.2.4
Conveyor curvature
Vertical curvature (varied heights on one belt) is common in conveyor design, but creates
difficulties for belt scales if not dealt with correctly. The curvature, whether concave (internal) or
convex (external), disturbs the idler alignment, if the scale is installed in the area of curvature.
The concave curve tends to lift the belt off of the idlers in the area of curvature as belt loading
decreases, adversely affecting the zero calibration.
Note
Avoid locating the scale within the tangents of scale curvature.
Concave
①
②
③
Minimum 12 m (40 ft)
Tangents
Belt scale
Convex
①
②
③
④
Minimum 6 m (20 ft)
Minimum 12 m (40 ft)
Tangents
Belt scale
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
17
Installing/Mounting
4.2 Conveyor considerations
4.2.5
Belt ploughs
Belt ploughs or any conveyor or material control device that changes the profile of the carrying
belt in or near the scale area is not recommended. These devices can negatively affect the belt
scale idler alignment and usually create drag on the belt which the scale senses as a material
force of load.
Note
Do not install the scale within 9 m (30 ft) of belt ploughs or similar devices that contact the
material or belt.
4.2.6
Stacker conveyors
Any conveyor that is not a permanent structure, which varies in its incline, elevation or profile is
not considered a good installation for an accurate belt scale. A belt scale can be used effectively
in this conveyor type, but requires special setup. Siemens offers an inclinometer for use with
variable incline conveyors.
4.2.7
Conveyor trippers
Note
On a conveyor with a tripper car, locate the scale under the recommendations for vertical
curves, but with the tripper fully retracted.
Milltronics MSI and MMI
18
Operating Instructions, 06/2012, 7ML19985CY04-04
Installing/Mounting
4.2 Conveyor considerations
4.2.8
Skirt boards and sealing strips
Sometimes it is necessary to extend the infeed skirt boards and sealing strips the full length of
the conveyor. This can create problems in weighing accuracy if the sealing strips exert excess
force when contacting the belt and indirectly upon the idlers, especially where pinching occurs.
The situation adversely affects the zero calibrations.
①
②
③
④
Skirt board
Sealing strip dragging along belt
Pinching can occur here
Idler
Note
If possible, remove skirting in scale area. If not, adjust skirting so sealing strip does not put
excess force on the belt or allow pinching of material.
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
19
Installing/Mounting
4.2 Conveyor considerations
Load cell handling
The MSI and MMI belt scales are designed for medium- to high-capacity operation and use two,
four, or six load cells. The load cells are protected by shipping stops to keep them from moving,
but the scale still needs to be handled with care to avoid damage. Shipping stops are 107 mm
(4.25") metal strips with holes at each end for screws. One screw holds the stop to the dynamic
section and the other screw holds the stop to the static section.
● When handling the belt scale during installation and set-up, make sure the stops remain in
place. Always re-install both shipping stops during maintenance or prolonged shutdown.
①
②
③
'A' screws
shipping stop
'B' screws
Milltronics MSI and MMI
20
Operating Instructions, 06/2012, 7ML19985CY04-04
Installing/Mounting
4.3 Installation procedure
4.3
Installation procedure
The following precautions should be observed when handling the scale.
● Do not pry on the idler, its mountings, or the cells directly.
● Do not stand or lean on the scale.
● Avoid shock from blows of a hammer when trying to position the scale during installation.
● Do not lift the scale by its idler.
● Do not lift the scale by the idler mounting brackets.
Note
For general safety and best system performance, the belt scale must be grounded
through the conveyor and the conveyor must be grounded to earth.
CAUTION
Arc welding
Use extreme caution when arc welding in the area of the belt scale. Ensure that no welding
current can flow through the belt scale. Welding currents passing through the scale can
functionally damage the load cells.
The MSI installation has eight stages:
1. Remove the idler(s)
2. Remove the idler foot plate
3. Idler mounting
4. Position the weigh bridge
5. Position the scale
6. Release the shipping stops
7. Align and level the idlers
8. Check alignment
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
21
Installing/Mounting
4.3 Installation procedure
4.3.1
Remove the idler
1. Remove the idler(s) from the desired location on the conveyor.
Milltronics MSI and MMI
22
Operating Instructions, 06/2012, 7ML19985CY04-04
Installing/Mounting
4.3 Installation procedure
4.3.2
Remove the idler foot plate and modify the idler frame at both ends
Remove the idler foot plate and modify the idler frame at both ends of the idler as shown below.
Occasionally, in less than 5% of applications, the combined effect of the idler rework and the
clamping of the scale at its inboard mounting position could result in abnormal idler vibration.
When this occurs, gusset plate reinforcements should be welded to the idler at the joints of the
horizontal spine and the outer vertical leg member.
12.7 mm
(0.5")
①
②
③
Before
After
See notes below
Note
Idler support
Cut idler support as shown to allow clearance when the load is applied. Maximum allowable
idler spine for fitting to a belt scale is:
 457 to 1346 mm (18 to 53") belt width options:
– angled spine: 75 mm (3"), channel spine: 120 mm (4.75")
 1372 to 1651 mm (54 to 65") belt width options:
– angled spine 100 mm (4.5"), channel spine 170 mm (6.75")
 1676 to 2438 mm (66 to 96") belt width options:
– angled spine 125 mm (5"), channel spine 184 mm (7.25")
4.3.3
Idler mounting:
The belt scale is usually installed in conveyors employing conventional rigid structure idlers.
Within this type of idler, construction will vary depending on the manufacturer and the
application. The idler depicted in this section uses an angle iron spine. The following images
depict alternate idler construction and tips on how they should be modified and installed.
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
23
Installing/Mounting
4.3 Installation procedure
● Troughed idler with channel spine
2
1
3
4
7
6
①
②
③
④
⑤
⑥
⑦
5
Customer's idler
Gusset reinforcement if required
12.7 mm (0.5")
100 mm (4")
After
Before
Foot pads welded to idler spine
Figure 4-1
Idler modification
①
②
Idler clip
Customer bolts (4 places)
Figure 4-2
Idler installation
Milltronics MSI and MMI
24
Operating Instructions, 06/2012, 7ML19985CY04-04
Installing/Mounting
4.3 Installation procedure
● Troughed idler with pipe spine
1
2
3
4
7
6
①
②
③
④
⑤
⑥
⑦
5
Customer's idler
Gusset reinforcement if required
12.7 mm (0.5")
100 mm (4")
After
Before
Foot pads welded to idler spine
Figure 4-3
Idler modification
①
②
③
Welded to idler pipe (be sure idler is square to scale & conveyor frame)
Idler clip
Customer bolts (4 places)
Figure 4-4
Idler installation
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
25
Installing/Mounting
4.3 Installation procedure
● Flat idler
2
1
3
5
①
②
③
④
⑤
4
Customer's idler
In most applications standard conveyor manufacturers' brackets cannot be used,
replacement brackets (as shown) are needed.
12.7 mm (0.5")
After
Before
Figure 4-5
Idler modification
①
②
Idler clip
Customer bolts (4 places)
Figure 4-6
Idler installation
Milltronics MSI and MMI
26
Operating Instructions, 06/2012, 7ML19985CY04-04
Installing/Mounting
4.3 Installation procedure
4.3.4
Position the weighbridge
Position the weigh bridge so that the center of the scale idler is centered between the adjacent
approach and retreat idlers. The belt scale is designed to use the existing holes in the stringer
and should not require further drilling.
Ensure that the scale is centered and square to the stringers and idler, and remove the idler
clamping brackets.
①
②
③
④
Belt travel
Location of removed idler
Test weights
Belt scale
Note
Clearance
Be sure there is sufficient clearance between the return belt, MSI, and its test weight (when
used during the calibration procedure).
4.3.5
Position the scale
Position the scale so that it is centered and square to the stringer. Mount the modified idler so
that it is centered on the scale using the idler clips (on large models, 1676 to 2438 mm (66 to
96") belt widths, the idler needs to be welded directly to the mount). Tighten all mounting
hardware.
Position the scale so that the large arrow on the scale mounting brackets is pointing in the
direction of belt travel.
①
②
Conveyor stringer
Idler clips
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
27
Installing/Mounting
4.3 Installation procedure
4.3.6
Release the shipping stops
Release the shipping stops in order to free the weighing mechanism. Loosen screws 'A' and
rotate both shipping stops inward until the underside slots slide around the screws 'B'. Tighten
screws 'A' to secure in place.
①
②
③
4.3.7
'A' screws
Shipping stop
'B' screws
Align and level the idlers
Align and level the idlers properly by shimming the scale idler, the two approach idlers, and the
two retreat idlers, until they are within ± 0.8 mm (1/32") of each other. Check that the idlers are
centered and squared to the conveyor during the shimming process.
90°
C
A2 ①
②
③
④
A1
R1
R2
Belt travel
Center of idlers to be in line
Idlers must be square to stringers
Alignment of idlers A2 to R2 to be within ± 0.8 mm (1/32")
Milltronics MSI and MMI
28
Operating Instructions, 06/2012, 7ML19985CY04-04
Installing/Mounting
4.3 Installation procedure
Note
Idler alignment
Precise idler alignment is very important to achieve maximum accuracy of the weighing
system. Misaligned idlers will result in unwanted forces being applied on each idler in the
weighing area, causing calibration and measurement errors.
4.3.8
Check alignment
Use a good quality wire or string to check for alignment. The wire or string must be able to
withstand sufficient tension in order to eliminate any sag. Adjust shims so that all rolls of the A2
through to the R2 idlers are in line within ± 0.8 mm (1/32").
$
$
5
5
①
②
MSI with modified idler
Wire or string (for alignment)
Although the accepted tolerance for idler alignment is ± 0.8 mm (1/32"), the scale-mounted idler
should never be lower than the adjacent idlers. Establishing good idler alignment is the most
important part of the installation procedure. Scale accuracy is directly affected by alignment.
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
29
Installing/Mounting
4.3 Installation procedure
General installation requirements for legal for trade applications
General Conveyor Requirements
1. Conveyor must be permanent construction.
2. The conveyor length shall be no longer than 300 m (1000 ft) nor shorter than 12 m (40 ft)
from head to tail pulley.
3. The scale must be so installed, that the nearest weigh idler of the scale is at least 6 m (20 ft)
or 5 idler spaces (whichever is greater) from either the end of the loading skirt boards or the
head pulley.
4. Scale must be mounted a minimum of 12 m (40 ft) from the tangent point of any curves in the
conveyor.
5. The conveyor must have a Gravity type take-up and that take-up must be operating properly.
6. Material feed to conveyor to be uniform and centered.
7. The conveyor belting shall be no heavier than is required for normal use.
8. The conveyor must be covered on the top and sides for a minimum distance of 9 m (30 ft)
each end of the scale idlers. The side covers must extend down to a distance approximately
0.6 m (2 ft) below the return belt line.
9. The electrical power to the scale equipment must remain on at all times.
10.The belt scale integrator must be located under cover, preferably in a control room, not
subject to direct sunlight.
Stringer Requirements
1. The belt scale shall be located close to a vertical conveyor support where conveyor stringer
deflection is near zero.
2. The conveyor Stringers in the scale area should be strong enough to limit relative deflection
to 0.8 mm (1\32").
3. The conveyor stringers must be straight to prevent any belt tracking problems.
Milltronics MSI and MMI
30
Operating Instructions, 06/2012, 7ML19985CY04-04
Installing/Mounting
4.3 Installation procedure
Conveyor Idler Requirements
1. The user must purchase and Install "eleven (11) Scale Quality Idlers", one idler to be
mounted on the MSI Weighbridge and 5 idlers to be mounted on the approach and retreat
side of the MSI Weighbridge.
The user must purchase and Install "twelve (12) Scale Quality Idlers", two idlers to be
mounted on the MMI Weighbridge and 5 idlers to be mounted on the approach and retreat
side of the MMI Weighbridge.
2. Do not use Scale Service Idlers: use Scale Quality Idlers.
3. Scale Quality idlers are high tolerance idlers; for roll run-out, frame deflection and alignment;
whereas Scale Service idlers are choice idlers selected from a production run having the best
roll run-out.
4. The scale-mounted idlers must be modified to ensure proper clearance for belt scale
deflection.
5. The Scale Quality Idlers must be aligned to within 0.5 mm (0.02") of each other or better.
6. The belt must remain in contact with all three rollers (center and wing rollers) of each of the
aligned idlers.
7. Idlers must be flat, 20 or 35 degree trough angle. All idlers on the conveyor must have the
same trough angle.
8. Training idlers must not be located within 18 m (60 ft) of any scale weigh idler.
See also
Metrological characteristics (Page 46)
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
31
Installing/Mounting
4.3 Installation procedure
Milltronics MSI and MMI
32
Operating Instructions, 06/2012, 7ML19985CY04-04
5
Connecting
①
②
③
④
Load cell A (C, E)
Load cell B (D, F)
See detail 'A'
Detail 'A'
Load
cell
MSI, MMI-2,
MMI-3
Integrator (MSI)
Integrator (MMI2)
Integrator (MMI3)
SIWAREX FTC
A
RED
+ EXC
+ EXC
+ EXC
+ EXC
BLK
- EXC
- EXC
- EXC
- EXC
WHT
- SIG 'A'
- SIG 'A'
- SIG 'A'
- SIG
GRN
+ SIG 'A'
+ SIG 'A'
+ SIG 'A'
+ SIG
SHIELD
SHIELD
SHIELD
SHIELD
SHIELD
RED
+ EXC
+ EXC
+ EXC
+ EXC
BLK
- EXC
- EXC
- EXC
- EXC
WHT
- SIG 'B'
- SIG 'B'
- SIG 'B'
- SIG
GRN
+ SIG 'B'
+ SIG 'B'
+ SIG 'B'
+ SIG
SHIELD
SHIELD
SHIELD
SHIELD
SHIELD
RED
+ EXC
+ EXC
+ EXC
BLK
- EXC
- EXC
- EXC
WHT
- SIG 'C'
- SIG 'A'
- SIG
GRN
+ SIG 'C'
+ SIG 'A'
+ SIG
SHIELD
SHIELD
SHIELD
SHIELD
B
C
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
33
Connecting
Load
cell
MSI, MMI-2,
MMI-3
D
E
F
Integrator (MSI)
Integrator (MMI2)
Integrator (MMI3)
SIWAREX FTC
RED
+ EXC
+ EXC
+ EXC
BLK
- EXC
- EXC
- EXC
WHT
- SIG 'D'
- SIG 'B'
- SIG
GRN
+ SIG 'D'
+ SIG 'B'
+ SIG
SHIELD
SHIELD
SHIELD
SHIELD
RED
+ EXC
+ EXC
BLK
- EXC
- EXC
WHT
- SIG 'A'
- SIG
GRN
+ SIG 'A'
+ SIG
SHIELD
SHIELD
SHIELD
RED
+ EXC
+ EXC
BLK
- EXC
- EXC
WHT
- SIG 'B'
- SIG
GRN
+ SIG 'B'
+ SIG
SHIELD
SHIELD
SHIELD
Milltronics MSI and MMI
34
Operating Instructions, 06/2012, 7ML19985CY04-04
6
Commissioning
6.1
Calibration
After all parts of the weighing system (belt scale, speed sensor, integrator) have been properly
installed and connected, the weighing system and integrator must be calibrated. The calibration
is initially done using the test weight(s), however material tests are recommended to achieve the
greatest accuracy. Refer to the integrator operating instructions for programming and calibration
details and for information about material tests. All operating instructions are available for
download at our web site:
Siemens weighing (http://www.siemens.com/weighing)
6.2
Test Load
The test load value is required for calibration of the integrator. Enter the calculated value into the
associated programming parameter of the integrator in kilograms per meter or pounds per foot.
The test load value is calculated as follows:
Test load =
6.3
Total weight of all test weights
Idler spacing
(Kgm ) or (lbft)
Balancing
For applications where the conveyor loading does not repeat in locations across the width of the
belt, such as side-to-side loading, electronic balancing of the two load cells is recommended.
Balancing is completed during the initial start-up, but should be repeated if either load cell is
reinstalled or replaced. Refer to the associated integrator manual to complete the balancing
procedure.
When balancing load cells, apply a test weight to the extreme sides (side A or B), as required.
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
35
Commissioning
6.4 Final calibration
6.4
Final calibration
Program the belt scale integrator as suggested in its operating instructions and with parameters
suitable for the application. With programming complete, the system is ready for calibration.
A zero calibration can be performed after sufficient running of the conveyor allows the belt to
limber up and take its natural formation. A zero calibration is performed in accordance to the belt
scale integrator operating instructions with the conveyor running empty.
6.5
Zero calibration
Perform the zero calibration as described in the Calibration section of the integrator operating
instructions.
After the completion of the zero calibration, a span calibration, as described in the belt scale
integrator operating instructions, can be performed with the test weight(s) applied. Be sure to
stop the conveyor when applying and removing the test weight.
6.6
Span calibration
1. The span reference (test load) is simulated using the test weight.
2. Apply the calibration test weight(s) to the scale.
①
②
MSI
Test weights
3. Perform the span calibration as described in the Calibration section of the integrator
operating instructions.
After completing the span calibration, remove the test weights and store them. With a successful
zero and span calibration, and with the test weight(s) removed from the belt scale, the belt scale
system is ready for operation. Ensure that the belt scale integrator is left in RUN mode.
Milltronics MSI and MMI
36
Operating Instructions, 06/2012, 7ML19985CY04-04
Commissioning
6.7 Material test
6.7
Material test
To achieve accuracy with respect to absolute values, perform material tests. Refer to the
associated integrator manual for instructions on material testing.
6.8
Re-rating
Consult your Siemens representative for any significant change in rate, speed, and/or idler
spacing from original design specifications to maintain proper design parameters.
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
37
Commissioning
6.8 Re-rating
Milltronics MSI and MMI
38
Operating Instructions, 06/2012, 7ML19985CY04-04
Service and maintenance
7.1
7
Maintenance
Keep the weighing equipment clean. Accumulation of material between the fixed support frame
(static) and the live frame (dynamic) as well as around each load cell could affect the scale
accuracy.
Periodically check the alignment of the stringers and idlers in the weighing area.
When a problem arises in the conveyor, it is possible that the scale will be affected. Therefore,
periodic conveyor maintenance is important to proper scale operation which should include:
● lubrication of all pulleys and idlers
● proper belt tracking and training
● proper belt cleaning and scraping
● proper take up operation
● proper material feeding and spillage control
You can observe the integrity of the load cells by performing zero and span calibrations. If the
zero and span deviations display a continuous unidirectional drift or the system cannot be
calibrated for any apparent mechanical reason, the load cells may be damaged.
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
39
Service and maintenance
7.2 Replacing a load cell
7.2
Replacing a load cell
CAUTION
Re-install the shipping stops during maintenance or any other time when protection of the
load cells is required.
1. Install both shipping stops
2. Support the belt and weighing idler from above or below.
3. Remove load cell hardware from the dynamic (moving) parts.
4. Remove load cell hardware from the static support.
5. Remove the existing load cell from the belt scale.
6. Replace with a new load cell fastening to static support then dynamic (moving structure).
7. Remove belt and idler support.
8. Release both shipping stops
9. Adjust idler alignment if necessary.
10.Perform balance, zero, and span calibrations.
7.3
Spare parts
The only spare part recommended for the belt scale is the load cell. Refer to the load cell
nameplate for the proper size and model number. Re-balance any load cell that has been
replaced.
Milltronics MSI and MMI
40
Operating Instructions, 06/2012, 7ML19985CY04-04
Service and maintenance
7.4 Technical support
7.4
Technical support
If you have any technical questions about the device described in these Operating Instructions
and do not find the right answers, you can contact Customer Support:
● Via the Internet using the Support Request:
Support request (http://www.siemens.com/automation/support-request)
●
Via Phone:
– Europe: +49 (0)911 895 7222
– America: +1 423 262 5710
– Asia-Pacific: +86 10 6475 7575
Further information about our technical support is available on the Internet at
Technical support (http://support.automation.siemens.com/WW/view/en/16604318)
Service & Support on the Internet
In addition to our documentation, we offer a comprehensive knowledge base online on the
Internet at:
Service & Support (http://www.siemens.com/automation/service&support)
There you will find:
● The latest product information, FAQs, downloads, tips and tricks.
● Our newsletter, providing you with the latest information about your products.
● Our bulletin board, where users and specialists share their knowledge worldwide.
● You can find your local contact partner for Industry Automation and Drives Technologies in
our partner database.
● Information about field service, repairs, spare parts and lots more under "Services."
Additional Support
Please contact your local Siemens representative and offices if you have additional questions
about the device
Find your contact partner at:
Local contact person (http://www.siemens.com/automation/partner)
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
41
Service and maintenance
7.4 Technical support
Milltronics MSI and MMI
42
Operating Instructions, 06/2012, 7ML19985CY04-04
8
Technical data
Accuracy
MSI
± 0.5% or better of totalization over 20 to 100% operating range
MMI-2
± 0.25% or better of totalization over 20 to 100% operating range
MMI-3
± 0.125% or better of totalization over 25 to 100% operating range
Accuracy subject to: On factory approved installations the belt scale systems totalized weight will be
within the specified accuracy when compared to a known weighed material test sample. The test
rate must be within the specified range of the design capacity and held constant for the duration of
the test. The minimum material test sample must be equivalent to a sample obtained at the test
flow rate for three revolutions of the belt or at least ten minutes running time, whichever is greater.
Load Cell
construction
17-4 PH (1.4568) stainless steel construction with
304 (1.4301) stainless steel cover,
316 (1.4401) stainless steel cover (optional)
degree of protection
IP67 rated
excitation
10 V DC nominal, 15 V DC maximum
output
2 mV/V excitation at rated load cell capacity
non-linearity
0.02% of rated output
hysteresis
0.02% of rated output
non-repeatability
0.01% of rated output
capacity
maximum ranges: 50, 100, 250, 500, 750, 1000,
1250, 1500 lb
overload
150% of rated capacity
ultimate 300% of rated capacity
temperature
-18 to +65 °C (0 to +150 °F) compensated
-40 to +75 °C (– 40 to +167 °F) operating range,
up to +175 °C (+347 °F) (optional)
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
43
Technical data
Belt width
18 to 96" in 1" increments to suit CEMA sizes, equivalent to 500 to 2000 mm in metric sizes
refer to Outline Dimensions
Belt speed
up to 5 m/s (984 fpm)
Contact Siemens application engineering for consideration of higher belt speeds.
Capacity
up to 12000 t/h (13200 STPH) at maximum belt speed
Conveyor incline
± 20° from horizontal, fixed incline
up to ±30° with reduced accuracy
Conveyor idler
flat to 35°
up to 45° with reduced accuracy
Idler diameter
50 to 180 mm (2 to 7")
Idler spacing
0.5 to 1.5 m (1.5 to 5.0 ft)
Milltronics MSI and MMI
44
Operating Instructions, 06/2012, 7ML19985CY04-04
Technical data
Interconnection (to integrator)
< 150 m (500 ft) 18 AWG 6 conductor shielded cable
> 150 m (500 ft) to 300 m (1000 ft.) 20 AWG 8 conductor shielded cable
Approvals
US/Canada
FM/CSA Class II, Div. 1, Groups E,F,G and Class
III
Europe
ATEX II 2D, Ex tD A21 IP65 T90 ºC
CE
International
IECEx Ex tD A21 IP65 T90 ºC
Australia
C-TICK
Russia
GOST-R
GOST-R Ex
Metrology approvals
MSI, MMI:
Canada
Measurement Canada
Europe
MID
International
OIML
China
CMC
MSI only:
South Africa
SABS
Russia
Pattern Approval
MMI only:
USA
NTEP
See also
Outline dimensions (Page 49)
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
45
Technical data
8.1 Metrological characteristics
8.1
Metrological characteristics
Metrological characteristics
UK/0126/0047
R50/1997-GB1-09.01
Accuracy class
≥1
Temperature range
Flowrate
Belt speed
-10 °C to +40 °C
Qmax:
Application dependent
Qmin:
20% of Qmax
Vmax:
Totalization scale interval
Weigh length
0.2 to 5.0 m/sec
≥ 0.001 t
L:
Application dependent
Climactic environment
Condensing, open
Electromagnetic environment
E1 and E2, electromagnetic disturbances likely
found in other industrial locations
Table 8- 1
Technical requirements
BW500 certification switch
When the switch is set for certification, editing of
the parameter values, span calibrations and
totalizer resets are denied.
Conveyor interlock
If the weighing instrument is switched off or
ceases to function, the conveyor belt shall stop,
or visible or audible indication shall be given.
Out-of-range indication
A continuous audible or visible indication shall be
given when the flowrate is above the maximum or
below the minimum value.
A continuous audible or visible indication shall be
given when the belt speed is above the maximum
or below the minimum value.
Totalization indicating devices
Remote totalization indicating devices shall be
permanently engaged.
Printing devices
Printing devices shall be permanently engaged.
Milltronics MSI and MMI
46
Operating Instructions, 06/2012, 7ML19985CY04-04
Technical data
8.1 Metrological characteristics
Installation conditions
The frame support of the conveyor shall be
constructed in a rigid manner.
The belt shall always be supported on the
weighing rollers.
Belt cleaning devices shall have no significant
effect on the results.
The product being weighed shall travel in the
same direction and speed as the belt.
Sealing
Components that are not intended to be adjusted
or removed by the user shall be fitted with a
sealing device.
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
47
Technical data
8.1 Metrological characteristics
Milltronics MSI and MMI
48
Operating Instructions, 06/2012, 7ML19985CY04-04
9
Dimension drawings
9.1
Outline dimensions
Note
Conduit and cable arrangement may differ from example shown
2
1
3
5
4
Milltronics MSI and MMI
Operating Instructions, 06/2012, 7ML19985CY04-04
49
Dimension drawings
9.1 Outline dimensions
Conveyor
belt width
③
Mounting
scale width
minimum
drop in width
⑤
②
①
④
18"
(457 mm)
27"
(686 mm)
23.25"
(591 mm)
9.5"
(241 mm)
5.5"
(140 mm)
7"
(178 mm)
82 lbs.
(37 kg)
20"
(508 mm)
29"
(737 mm)
25.25"
(641 mm)
9.5"
(241 mm)
5.5"
(140 mm)
7"
(178 mm)
85 lbs.
(39 kg)
24"
(610 mm)
33"
(838 mm)
29.25"
(743 mm)
9.5"
(241 mm)
5.5"
(140 mm)
7"
(178 mm)
90 lbs.
(41 kg)
30"
(762 mm)
39"
(991 mm)
35.25"
(895 mm)
9.5"
(241 mm)
5.5"
(140 mm)
7"
(178 mm)
99 lbs.
(45 kg)
36"
(914 mm)
45"
(1143 mm)
41.25"
(1048 mm)
9.5"
(241 mm)
5.5"
(140 mm)
7"
(178 mm)
107 lbs.
(49 kg)
42"
(1067 mm)
51"
(1295 mm)
47.25"
(1200 mm)
9.5"
(241 mm)
5.5"
(140 mm)
7"
(178 mm)
116 lbs.
(53 kg)
48"
(1219 mm)
57"
(1448 mm)
53.25"
(1353 mm)
9.5"
(241 mm)
5.5"
(140 mm)
7"
(178 mm)
125 lbs.
(57 kg)
54"
(1372 mm)
63"
(1600 mm)
59.25"
(1505 mm)
12"
(305 mm)
8"
(203 mm)
7"
(178 mm)
175 lbs.
(79 kg)
60"
(1524 mm)
69"
(1753 mm)
65.25"
(1657 mm)
12"
(305 mm)
8"
(203 mm)
7"
(178 mm)
193 lbs.
(88 kg)
66"
(1676 mm)
75"
(1905 mm)
71.25"
(1810 mm)
12"
(305 mm)
8"
(203 mm)
8"
(203 mm)
229 lbs.
(104 kg)
72"
(1829 mm)
81"
(2057 mm)
77.25"
(1962 mm)
12"
(305 mm)
8"
(203 mm)
8"
(203 mm)
247 lbs.
(112 kg)
weight
Other widths available. Sizes are from 18 to 96" (457 to 2438 mm) in 1" (25.4 mm) increments. All
sizes are nominal.
Milltronics MSI and MMI
50
Operating Instructions, 06/2012, 7ML19985CY04-04
www.siemens.com/processautomation
For more information
www.siemens.com/level
www.siemens.com/weighing
Siemens AG
Subject to change without prior notice
Industry Sector
7ML19985CY04 Rev. 4.1
1954 Technology Drive
© Siemens AG 2012
P.O. Box 4225
Peterborough, ON
Canada K9J 7B1
email: [email protected]
www.siemens.com/processautomation
*7ml19985CY04*
Printed in Canada

advertisement

Key Features

  • High accuracy
  • Heavy-duty construction
  • Continuous weighing
  • Dry bulk solids
  • Single or multiple idler configuration
  • Easy installation
  • Adjustable calibration
  • Durable design
  • Reliable performance
  • Suitable for process control

Frequently Answers and Questions

What types of materials can be weighed with Milltronics MSI and MMI belt scales?
Milltronics MSI and MMI belt scales are designed for weighing dry bulk solids. This includes materials such as sand, gravel, cement, coal, grain, and other similar materials.
What is the accuracy of Milltronics MSI and MMI belt scales?
The accuracy of Milltronics MSI and MMI belt scales depends on various factors, including the conveyor system, installation, and alignment. However, they are designed to provide high accuracy for weighing purposes.
How do Milltronics MSI and MMI belt scales work?
Milltronics MSI and MMI belt scales work by measuring the weight of material as it travels over a suspended idler on the conveyor belt. The idler is connected to load cells that sense the weight and transmit a signal to an integrator. The integrator then calculates the total weight of material passing through the scale.

Related manuals

Download PDF

advertisement