Below you will find brief information for Programmable Wall Switch TI033. The TI033 is a programmable wall switch designed to control lighting and motors. It can be programmed to turn lights on and off at specific times, and can be used to control a variety of loads, including incandescent lights, halogen lights, fluorescent lights, and motors. The TI033 features a user-friendly interface, and is easy to program and use.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
TI033
Installation and User Guide
Programmable Wall Switch
n
1.
Applications
q
4.
Setting the Clock
The TI033 programmable wall switch has been designed to control
lightings and motors:
NOTE: The switch displays the time in 24-hour format by default or
following a reset.
Load type
Maximum load
Examples
n
Resistive load
2400 W
(20 A @ 120 V)
•
•
•
incandescent lights
halogen lights
block heater
Inductive load
2400 W
(20 A @ 120 V)
•
•
•
•
fluorescent lights
compact fluorescent lights (CFL)
sodium lamps
electronic ballasts
Motor
1 hp
•
•
pool filter pumps
fans
o
a) Press one of the control buttons to ensure the MAN or
AUTO indicator is displayed.
Installation
Cut power at the circuit breaker to avoid electric shock.
Remove the existing switch.
Set the time using the HOUR and MIN buttons. If you have
selected the 12-hour format, ensure that PM appears on the
screen when an afternoon time is displayed.
Set the day by using the DAY button.
Press one of the control buttons or close the switch door to
return to normal operation.
r
5.
Selecting the Operating Mode
The programmable switch has 2 operating modes: manual (MAN)
and automatic (AUTO). To switch mode, press the switch door for 3
seconds.
Install the new switch as shown in the diagram below.
Manual Mode
The programmable switch operates as a regular
switch. Briefly press the switch door to turn the lights
On or Off. The mode (MAN) and state (ON or OFF)
are displayed.
Apply power at the circuit breaker.
white
Automatic Mode
The programmable switch follows the programmed
schedule. The mode (AUTO), state (ON or OFF)
and current program number are displayed.
To temporarily override the programmed schedule,
briefly press the switch door. The new state (ON or OFF) will flash to
show that this state is temporary. The override remains in effect until
you press the switch door again or until the beginning of the next
program.
blue
black
white
white (neutral)
120 VAC black (line)
p
3.
Power-On
Pry the switch door open from the
bottom using a small screwdriver.
Reset
o Ensure the ON/OFF selector is set
Control (4)
to ON.
p Reset the switch using a paper clip.
On/Off
0:00 and MO will flash.
selector
If the display is blank:
•
Ensure the ON/OFF selector is properly engaged in the ON position. Push it to the right using a small screwdriver.
TI033
o
2.
black
n
b) Press the MIN and HOUR buttons simultaneously and brieftly (0:00 display = 24-hour, 12:00 display = 12-hour ).
p
q
NOTE: This switch cannot be used if there are not at least 2 white
wires joined by a connector inside the electrical box.
n
o
p
q
To change to 12-hour format (or vice versa), proceed as follows:
s
6.
Programming
You can set up to 7 programs. To set a program, you need to enter its
start time (ON) and its end time (OFF).
n
o
p
Pry the switch door open using a small screwdriver.
Press the PGM button to display a program and
its On or Off time. For example, when you first
press PGM, program number 1 (P1) and its On
time (ON) will appear. - : - - will appear instead
of the time if the program is not set (inactive).
Press the DAY button to select the day to which
you want to apply the program.
NOTE: If you want to apply the program to
every day of the week, press DAY until all the
days are displayed. (This still counts as 1 program, not 7)
400-033-001-C
30/11/06
1/2
q
r
s
Press the HOUR and MIN buttons to set the ON time (time when
you want the lights to turn on). If you have selected the 12-hour
format, ensure that PM appears on the screen when an
afternoon time is displayed.
After you have programmed the ON time, press the PGM button
to display the OFF time (time when you want the lights to turn
off).
Repeat steps 3 through 5 to program the OFF
time. If the program ON time is set for every day
of the week, the program OFF time will
automatically be set for every day.
t
To set another program, repeat steps 2 through 6. Programs that
are not set will remain inactive.
u
Press one of the control buttons or close the switch door to
return to normal operation.
Clearing a Program
Press the PGM button until the desired program is selected. Hold the
PGM button for 3 seconds. - : - - appears when the program is
erased.
t
7.
Troubleshooting
Blank display
• Verify circuit breaker at main panel.
• Ensure the ON/OFF selector is at ON.
• Reset the switch using a paper clip.
Faded or irregular
display
Ambient
point
Cannot switch between
24-hour format and
12-hour format
First, press one of the control buttons so
that MAN or AUTO appears on display.
Programs do not run
as expected
• Make sure the switch is properly programmed.
• Note that - : - - indicates an inactive program, 00:00 indicates midnight.
• If the switch has been configured for
12-hour format, check that PM appears
on the left side of the screen when an
afternoon time is displayed.
The switch resets itself
without apparent reason when used to control an inductive load
such as a relay or a
contactor.
u
temperature
below
freezing
The reset is caused by the load. Install a
snubber (AC130-03) at each relay/contactor.
8.
Technical Specifications
Supply: 120 VAC, 50 / 60 Hz
Maximum load: 2400 watts resistive or inductive, 1 HP motor
Operating temperature range: 5°F to 122°F (-15°C to 50°C)
Storage temperature range: -4°F to 122°F (-20°C to 50°C)
Power outage: The programs are protected by a rechargeable
battery. The screen is blank during the power outage.
Certifications: CSA & UL
TI033
;
9.
Warranty
AUBE warrants this product, excluding battery, to be free from
defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the
consumer. If at any time during the warranty period the product is
determined to be defective or malfunctions, AUBE shall repair or
replace it (at AUBE's option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to
the place from which you purchased it, or
(ii) contact AUBE. AUBE will make the determination whether the
product should be returned, or whether a replacement product
can be sent to you.
This warranty does not cover removal or reinstallation costs. This
warranty shall not apply if it is shown by AUBE that the defect or malfunction was caused by damage which occurred while the product
was in the possession of a consumer.
AUBE's sole responsibility shall be to repair or replace the product
within the terms stated above. AUBE SHALL NOT BE LIABLE FOR
ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF
THIS PRODUCT. Some provinces, states or regions do not allow the
exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE
MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED
WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS
WARRANTY. Some provinces, states or regions do not allow limitations on how long an implied warranty lasts, so the above limitation
may not apply to you.
This warranty gives you specific legal rights, and you may have other
rights which vary from one province, state or region to another.
10.
Customer Assistance
If you have any questions on the product installation or operation,
contact us at:
705 Montrichard Avenue
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel.: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
Email: [email protected]
For more information on our products, go to
www.aubetech.com
400-033-001-C
30/11/06
2/2
To set the clock, press one of the control buttons to ensure the MAN or AUTO indicator is displayed. Then, use the HOUR and MIN buttons to set the time. If you have selected the 12-hour format, ensure that PM appears on the screen when an afternoon time is displayed. Set the day by using the DAY button. Press one of the control buttons or close the switch door to return to normal operation.
How do I program the TI033 to turn on the lights at 6:00 PM every day?
To program the TI033 to turn on the lights at 6:00 PM every day, you will need to set up a program. Press the PGM button to display a program and its On or Off time. Press the DAY button to select the day to which you want to apply the program. Press the HOUR and MIN buttons to set the ON time (time when you want the lights to turn on). After you have programmed the ON time, press the PGM button to display the OFF time (time when you want the lights to turn off). Repeat steps 3 through 5 to program the OFF time. Press one of the control buttons or close the switch door to return to normal operation.
What is the maximum load that the TI033 can handle?
The TI033 can handle a maximum load of 2400 watts for resistive or inductive loads, or 1 HP for a motor.
How do I reset the TI033?
To reset the TI033, use a paperclip to push the reset button located on the switch. 0:00 and MO will flash on the display.
Assistant typing
Assistant terminated
Hello, I'm AI chat bot, can I help you?
The AI has read the AUBE TI033 Programmable Wall Switch Installation and User Guide and is ready to answer your questions. The more detailed you describe the issue, the easier it will be for it to find the answer in the manual.