Sanyo VCC-9600P is a high-quality Color CCD camera designed for various surveillance applications, featuring a 1/3-inch CCD sensor for crisp and clear images, a resolution of 480 TV lines for sharp details, and a minimum illumination of 0.7 lux for low-light conditions. With automatic white balance and electronic shutter speed adjustment, it adapts to changing lighting conditions to deliver optimal image quality.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
L5BU2_XE(INSTALLATION).book 0 ページ 2006年12月8日 金曜日 午後3時55分
INSTALLATION MANUAL
Color CCD Camera
Install these units securely according to this installation manual. Be aware that allowing them to fall may cause personal injury.
This installation should be made by a qualified service person and should conform to all local codes.
Please read this manual before installing and using this unit, and always follow the instructions in it for proper use. Please also read the separate Instruction Manual before using the unit for proper use.
Contents
Product Lineup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Surface Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
In-ceiling Mount (Closed Type) . . . . . . . . . . . . . . . . . . 3
In-ceiling Mount (Open Type) . . . . . . . . . . . . . . . . . . . . 4
Connections and Settings . . . . . . . . . . . . . . . . . . . . . . 5
Address Settings Table . . . . . . . . . . . . . . . . . . . . . . . . . 7
Pattern Sheet (inserted at the end of this manual)
Important
• Be careful when opening holes for installing the unit.
Work with the power and video cables pulled out for easy installation.
• Make sure to properly perform waterproofing for the ceiling where you are installing the unit.
• Make sure that the surface in the installation location has no unevenness and is strong enough to bear the total weight of the unit.
• Install this unit in an environment where the temperature range stays between -10°C and +50°C
(no condensation allowed).
CAUTION: For VA-80S (Power Borard Unit)
ALL-POLE MAINS SWITCH with a contact separation of at least 3mm in each pole shall be incorporated in the electrical installation of the building.
Before Installing the Unit
1
Remove the plastic cover (A) and then the tape (B) fixing the lens.
2
Put back the plastic cover (A) and lock it securely.
● Turn the cover clockwise until it clicks.
1
2
(A)
(B)
L5BU2_XE(INSTALLATION).book 1 ページ 2006年12月8日 金曜日 午後3時55分
Product Lineup
To install the camera unit, the optional housing is required. When using a housing, be sure to choose the correct one for your environment of use.
☞ For instructions on how to install the outdoor type, the wall mounting bracket, pendant mounting bracket, and
attachment, refer to the relevant instruction manuals.
Power Board Unit
(VA-84S; for AC24V)
(VA-80S; for AC230V)
Camera unit
(In-ceiling Mount)
Indoor Type
(Surface Mount)
☞P3 ☞P4 ☞P2
Outdoor Type
Pendant Mounting
Bracket (VA-80BP)
Wall Mounting
Bracket (VA-80BW)
Corner Mounting
Adapter (VA-80AC)
Pole Mounting
Adapter (VA-80AP)
In-ceiling
Bracket
Closed Type
(VA-80ME)
In-ceiling
Bracket
Open Type
(VA-80MF)
Attachment (VA-80A)
Outdoor Housing (VA-80EX)
● Clear Dome Cover (VA-CM8C)
● Smoked Dome Cover (VA-CM8S)
Surface Cover (VA-80F)
– 1 –
L5BU2_XE(INSTALLATION).book 2 ページ 2006年12月8日 金曜日 午後3時55分
Surface Mount
Make sure to also consult the Surface Cover Instruction Manual.
1. Installing the power board unit
1 Place the pattern sheet at the end of this manual on
the ceiling, mark the locations and drill the holes for the cables and screws.
2 Pull out the cables from the ceiling.
3 Attach the supplied dust sheet (A) to the base of the
power board unit and the detachable piece of the sheet (B) to the side.
☞ Peel off the release-coated paper from the dust sheet before attaching.
4 Pass the cables through the slit (C) in the dust sheet.
5 Fix the power board unit to the ceiling using the
supplied screws (D) (4 places).
6 Connect the cables and set the switches.
☞ See “Connections and Settings” on page 5.
3
Surface routing (ceiling)
Pass the cables through the cable hole
(E) at the side of the power board unit, and attach the dust sheet
(A) as shown in the figure.
E
2. Mounting the camera unit
7 Fasten the camera unit safety wire (F) to the hook (G)
on the inner side of the power board unit.
8 Align the arrows (H) of the same color (blue) on the
camera unit and the power board unit, and push the camera unit until they click.
9 Align the arrows (H) of the same color (blue) on the
inner side of the surface cover and the power board unit, and fix the cover by rotating it clockwise.
F
7
1
4
C
6
D
■ How to attach the drop-prevention cable
(accessory)
1) Peel off the two-sided tape (K) at the end of the cable and attach it to the hook (L) on the inner side of the surface cover as shown in the figure.
2) Fasten the cable to the hook (M) on the side of the power board unit.
M
To remove the camera unit
2
1
8
5
D
G
9
H; Blue
H; Blue
K
Removed in case of surface routing.
Protrusion
L
Accessories
– 2 –
Dust sheet Drop-prevention cable
Screw (for power board unit)
L5BU2_XE(INSTALLATION).book 3 ページ 2006年12月8日 金曜日 午後3時55分
In-ceiling Mount (Closed Type)
Make sure to also consult the In-ceiling Bracket Closed Type Instruction Manual.
φ192 mm (7.6”)
1. Installing the power board unit
1 Draw a circumference on the ceiling using the
supplied drop-prevention cable (A) as compass, and drill a hole for installing the in-ceiling bracket.
2 Pull out the cables from the ceiling.
3 Pass the supplied screws (B) through each of the
power board unit screw holes and fasten them loosely using washers (4 places).
4 Align the arrows (C) of the same color (blue) on the
power board unit and the in-ceiling bracket, and mount the power board unit. Tighten firmly the screws (B) loosely fastened in the previous step.
● Pass the video cable (D) through the bracket cable hole as preparation for the next step.
2
A
1
C; Blue
3
3
3
4
3
B
D
2. Installing on the ceiling
5 Attach the supplied safety wire (E) to the ceiling
beam, for example, then connect it to the bracket-top hook (F).
6 Connect the video cable and pass the connection
cables through the bracket.
7 Insert the bracket into the ceiling hole and fix it
using screws (G) (2 places).
8 Connect the cables and set the switches.
☞ See “Connections and Settings” on page 5.
9 Align the arrows (C) of the same color (blue) on the
camera unit and the inner side of the bracket, and push the camera unit until they click.
F Align the SANYO logos on the supplied bracket
cover and the bracket, and push the cover until they click.
■ How to attach the drop-prevention cable
(accessory)
Fasten the drop-prevention cable (A) to the hooks (H) on the bracket and its cover, then slide the cable as shown in the figure.
G
6
7
5
9
E
F
F
G
F
8
G
7
C; Blue
H
5
E
To remove the camera unit
G
A
H
Accessories
Screw, washer
(for power board unit)
Drop-prevention cable
Safety wire Bracket cover
– 3 –
L5BU2_XE(INSTALLATION).book 4 ページ 2006年12月8日 金曜日 午後3時55分
In-ceiling Mount (Open Type)
Make sure to also consult the In-ceiling Bracket Open Type Instruction Manual.
φ192 mm (7.6”)
1. Installing the power board unit
1 Draw a circumference on the ceiling using the
supplied drop-prevention cable (A) as compass, and drill a hole for installing the in-ceiling bracket.
2 Pull out the cables from the ceiling.
3 Pass the supplied screws (B) through each of the
power board unit screw holes and fasten them loosely using washers (4 places).
4 Mount the power board unit in the in-ceiling bracket.
Tighten firmly the screws (B) loosely fastened in the previous step.
● When inserting the power board unit, do it diagonally.
2
A
1
B
3
3
2. Installing on the ceiling
5 Attach the supplied safety wire (C) to the ceiling
beam, for example, then connect it to the bracket-top hole (D).
6 Connect the video cable and pass the connection
cables through the bracket.
7 Insert the bracket into the ceiling hole and fix it
using screws (E) (2 places).
8 Connect the cables and set the switches.
☞ See “Connections and Settings” on page 5.
9 Align the blue sticker (F) on the bracket and the
arrow (F) of the same color on the camera unit, and then push the camera unit until they click.
F Align the SANYO logos on the supplied bracket
cover and the bracket, and push the cover until they click.
E
■ How to attach the drop-prevention cable
(accessory)
Fasten the drop-prevention cable (A) to the hooks (G) on the bracket and its cover, then slide the cable as shown in the figure.
6
7
5
D
C
D
E
8
E
7
9
G
F; Blue
A
G
Accessories
F
3
4
3
5
C
To remove the camera unit
E
Screw, washer
(for power board unit)
Drop-prevention cable
Safety wire Bracket cover
– 4 –
L5BU2_XE(INSTALLATION).book 5 ページ 2006年12月8日 金曜日 午後3時55分
Connections and Settings
Do not connect the power cord until all other connections have been completed.
Make sure to also consult the Power Board Unit Instruction Manual.
G
Power Supply Connection
N L
For the connections use cables higher than
18 AWG.
Monitor Connection
Supported coaxial cables
Cable type
RG-59U (3C-2V)
RG-6U (5C-2V)
RG-11U (7C-2V)
Length
250 m (273.4 yd) max.
500 m (546.8 yd) max.
600 m (656.2 yd) max.
<Live>
<Neutral>
<Ground>
AC 24 V or
AC 230 V
• Fix the power cable end firmly so that the power terminal connection does not come loose. Use solderless terminals (ring or spade type) for wiring.
• After connection, always install the supplied power terminal cover A for safety reasons.
A
• Using different cables from those specified here may attenuate the video and/or sync signals and interfere with correct transmission.
• RG-59U coaxial cables can be used when distance between devices is short, but not in duct or aerial routing.
BNC type
Joint board
SIDE-A
Connections
All connection cables should be 24 AWG or higher with a maximum length of no more than 600 m.
1
Controller connection
White Yellow
485A
485B
2
Alarm signal input
To COM
IN 1 - 8 Alarm input signal
3
Alarm signal output
If a lamp is connected to this cable, it will light up when an alarm signal is received or when the built-in motion sensor detects movement.
To COM
OUT 1/2
Alarm output signal
For details on 2 and 3, refer to the “Alarm Settings (ALARM)” in the Instruction Manual.
CAMERA
LENS
PAN/TILT
AUTO MODE
ALARM
PRIVACY MASK
PASSWORD
LANGUAGE
OPTION
PRESET
MENU
SET
SET
SET
SET
SET
SET
SET
SET
SET
OFF
BACK y
ALARM
ALARM IN
ALARM OUT
ALARM DISABLE
MOTION
ALARM DISPLAY
1
1
OFF
OFF
OFF y
PRESET
MENU
OFF
BACK
2
1
1
System control setting switches
• Switch 6 is unused.
• The factory setting is represented in bold.
ON
1 2 3 4 5 6
1 234
1
Baud rate
Set the same baud rate as that on the camera.
Switch
2400
4800
9600
19200
1 2
OFF OFF
OFF ON
ON OFF
ON ON
2
Control method
Set either to RS485 or coaxial (COAX).
Switch
Coaxial (COAX)
RS485
3
ON
OFF
3
Protocol
Set the protocol for controlling the camera.
Switch
SSP (SANYO)
PELCO
4
OFF
ON
4
Termination (Switch 5)
“OFF” is set by default.
When connecting multiple cameras, termination setting must be “ON” on the last camera while it must be “OFF” on all others.
2
Address setting switches
Set the camera address.
See “Address Settings Table” on page 7.
ON
1 2 3 4 5 6 7 8
– 5 –
L5BU2_XE(INSTALLATION).book 6 ページ 2006年12月8日 金曜日 午後3時55分
Connections and Settings
■ To prevent electromagnetic interference
Be sure to attach the clamping cores supplied with the camera unit to the cables as illustrated.
Power cable
Control and alarm input/output cables
Video cable
■ Connections for using coaxial control (System connection)
Video input terminal
(1 - 16)
Video input terminal
Camera Camera
Digital video recorder (sold separately)
1
IN
OUT
2 3 4 5 6 7 8
MONITOR OUT
MAIN MON2
9 10 11 12 13 14 15 16
A RS-485 B
DO NOT CONNECT TO PHONE LINE
Terminator switch
Monitor
(sold separately)
Video input terminal
Communication conversion connectors
A TELEMETRY B VIDEO
System controller
(sold separately)
– 6 –
L5BU2_XE(INSTALLATION).book 7 ページ 2006年12月8日 金曜日 午後3時55分
Address Settings Table
Addresses are specified by setting the switches to ON/OFF.
In the table, the circle mark “m” means ON. Set switches as shown in the table.
SANYO protocol: 1 - 127 PELCO protocol: 1 - 255
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Switch 8
• Address 1 - 127: OFF
• Address 128 - 255: ON
• Switch 8 is unused.
Address
(Camera No.) Switch No.
Protocol
SANYO/PELCO PELCO 1 2 3 4 5 6 7
0* 128
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m
Address
(Camera No.)
Protocol
Switch No.
SANYO/PELCO PELCO 1 2 3 4 5 6 7
43 171
m m m m
44
45
46
172
173
174
m m m m m m m m m m m
47
48
49
50
51
52
53
54
55
56
175
176
177
178
179
180
181
182
183
184
m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m
Address
(Camera No.)
Protocol
Switch No.
SANYO/PELCO PELCO 1 2 3 4 5 6 7
86 214
m m m m
87
88
89
215
216
217
m m m m m m m m m m m m
90
91
92
93
94
95
96
97
218
219
220
221
222
223
224
225
m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m
* When setting the address by using the menu screen on the camera, set the address setting switches to “0”.
– 7 –
L5BU2_XE(INSTALLATION).book 0 ページ 2006年12月8日 金曜日 午後3時55分
Pattern Sheet:
mm (inch)
4-
φ4.5 (0.2)
P. D
φ168 (6.6)
166 (6.5)
Scale: 1/1
L5BU2_XE(INSTALLATION).book 1 ページ 2006年12月8日 金曜日 午後3時55分
b Dimensions: mm (inch)
φ
136 (5.4)
Printed on recycled paper
Imprimé sur du papier recyclé
Impreso en papel reciclado
Gedruckt auf Recyclingpapier
使用再生纸印刷
1AC6P1P3149--
L5BU2/XE (1206KP-SY)
SANYO Electric Co., Ltd.
Printed in Japan