Digital Lighting Systems MF802-12, MF802-24, MF802-120, MF802-220, MF802-12DC, MF802-24DC 8 Channel Fader/ Chaser User's Manual

Digital Lighting Systems MF802-12, MF802-24, MF802-120, MF802-220, MF802-12DC, MF802-24DC 8 Channel Fader/ Chaser User's Manual

Below you will find brief information for 8 Channel Fader/ Chaser MF802-12, 8 Channel Fader/ Chaser MF802-24, 8 Channel Fader/ Chaser MF802-120, 8 Channel Fader/ Chaser MF802-220, 8 Channel Fader/ Chaser MF802-12DC, 8 Channel Fader/ Chaser MF802-24DC. The MF802 is an Eight channel single-phase AC lighting controller capable of producing slow level changes( Color Mixing ) as well as Quick ON/ OFF ( Animation). It contains the equivalent of 2 sets of four solid-state relays (SSR) 8 dimmers, with two power line feed. Each dimmer is rated at a maximum output current of 2.5 Amperes. The SSR dimmers are controlled by low-voltage DC signals from the logic circuit on the board. These signals are electrically-isolated by Optical couplers from all line voltage elements.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Digital Lighting Systems MF802-12,MF802-24,MF802-120,MF802-220,MF802-12DC,MF802-24DC User Manual | Manualzz

Digital Lighting Systems, Inc.

MF802

8

Channel “Mini-Fader/ Chaser ”

Cross Fader/ color mixing/ Animation chaser

MF802-12/MF802-24/MF802-120/MF802-220

MF802-12DC/ MF802-24DC

USER'S MANUAL

MF802-UM

06/09

Digital Lighting Systems

www.digitallighting.com

MF802

8 channel

User's Manual - Page 1

16 Pattern

General Description

The MF802 is an Eight channel single-phase AC lighting controller (Cross-

Fader/Lighting animation) capable of producing slow level changes( Color Mixing ) as well as Quick ON/ OFF ( Animation)

A functional block diagram of the MF802 is shown in Figure 1. MF802 contains the equivalent of 2 sets of four solid-state relays (SSR) 8 dimmers, with two power line feed. Each dimmer is rated at a maximum output current of 2.5 Amperes. The SSR dimmers are controlled by low-voltage DC signals from the logic circuit on the board.

These signals are electrically-isolated by Optical couplers from all line voltage elements. The MF802 logic board contains a powerful microprocessor programmed to generate 16 user-selectable light sequences or patterns at an adjustable rate (the

MF802 is also available with a “SPELLER” pattern or custom patterns upon request). A rotary selector is used to select the pattern and a second one is used to set the rate or speed. Patterns and speed can be monitored by Eight LED's that represent the outputs of the MF802. The MF802-120 and MF802-220 Require Logic power from an external step down transformer with output rates at 300mA 8 VAC to 12 VAC

Please contact the factory for additional information by telephone 1-305-969-8442 or email [email protected]

H1

N N 1 2 3 4

Figure 1

- MF802 Functional Block Diagram

H2

N N 5 6 7 8

Table 1 - Terminals Definition

NAME DESCRIPTION

1,2,3,4

Output Of

H1

Solid-State Relays #1,2,3,4

Hot Line Feed For

N

Relays 1 , 2 , 3 & 4.

Neutral Bus/ Common Connections.

SSR's OPTICAL ISOLATORS

MF Logic Control

Board

9 VAC

Transformer

External

SSR's OPTICAL ISOLATORS

Signal cable ch. 5 to 8

5,6,7,8

Output Of

H2

Solid-State Relays #5,6,7,8

Hot Line Feed For

N

Relays 5 , 6 , 7 & 8.

Neutral Bus/ Common Connections.

Table 2 - Maximum Electrical Ratings

Electrical Characteristic Terminal Maximum

Relay Load Current 1 to 8 2.5 Amps.

Input Current H1,H2 10 Amps.

Input Voltage depends on model VAC/VDC

12302 SW 128th ct,UNIT 105, Miami, Fl. 33186

Tel: 305-969-8442

Fax: 305-969-8675

www.digitallighting.com

Copyright 2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

Digital Lighting Systems

www.digitallighting.com

MF802

-120 Detail

MF802

8 channel

Figure 2 - MF802-

User's Manual - Page 2

16 Pattern

Fader / Chaser

16A

19A

OUTPUT TERMINAL

H1 N N 1 2 3 4

17A

19B

16B

OUTPUT TERMINAL

H2 N N 5 6 7 8

17B

15A

11A 12A

2

3

1

S1 S2

10

4

13A 14A

18A

15B

11B 12B

C1

6

5

9

8

7

13B 14B

18B

C2

Table 3 - MF802-120 Circuit Legend

7

8

5

6

3

4

1

2

9

10

11A,12A,13A,14A

11B,12B,13B,14B

15A,16A,17A,18A

15B,16B,17B,18B

19A,19B

S1

S2

C1,C2

Microprocessor.

Not Used

Not Used

Quartz Crystal.

Power Supply Capacitor.

Voltage Regulator.

4 or 3 channel jumper selection

Logic power connector

Output LED Monit ors.

Jumper for Chasing

Optical Coupl ers # 1,2,3,4

Optical Coupl ers # 5,6,7,8

Triacs # 1,2,3,4 f or VAC; MOSFETs for VDC

Triacs # 5,6,7,8 f or VAC ; MOSFETs for VDC

Fuses 5mm, 10Am ps

Speed selector 0 = Slowest ; F = fastest

Pattern Select or

Connectors for CH 5,6,7,8 control cabl e

12302 SW 128th ct,UNIT 105, Miami, Fl. 33186

Tel: 305-969-8442

Fax: 305-969-8675

www.digitallighting.com

Copyright 2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

Digital Lighting Systems

www.digitallighting.com

MF802

8 channel

User's Manual - Page 3

16 Pattern

Fader / Chaser

Mechanical Installation

The MF802 modules are designed to be mounted in NEMA enclosures( by others).

4.30" 4.30"

Mounting hole

For # 6 screw

Mounting hole

For # 6 screw

10 A.

Fuse

2

1

-

2

MF802-xxxx

Optocouplers

3

3

1

Mounting hole

For # 6 screw

4

SF408

V0.2

4

S2

Microprocessor

C

B

E

F

0

1

2

3

A 9

8

6

7

C

E

F

0

1

2

3

6

A

B

9

8

7

S1

For Chasing

Place jumper

Pattern Speed

Channel Indicators

1

9 VAC

10 A.

Fuse

6

5

5

Mounting hole

For # 6 screw

6

MF802-xxxx

Optocouplers

7

Channel Indicators

5

7

8

8

Figure 3 - MF802 Dimensional Diagram

12302 SW 128th ct,UNIT 105, Miami, Fl. 33186

Tel: 305-969-8442

Fax: 305-969-8675

www.digitallighting.com

Copyright 2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

Digital Lighting Systems

www.digitallighting.com

MF802

8 channel

User's Manual - Page 4

16 Pattern

Fader / Chaser

MF802-120 General Wiring Instructions for 120V version.

Wiring Notes

0 DO NOT EXCEED 300 W (2.5 Amps. ) per circuit output @ 120VAC.

0 MF802 Fader packs may be fed by one 15 A (maximum) branch circuit and may have up to four separately dimmed loads.

0 Loads connected to outputs must be dimmable.

0 CAUTION: DO NOT attempt to parallel outputs to increase capacity.

0 Installations must conform to local and/or NEC code requirements.

0 Each load must have its own Neutral wire for full load operation.

0 All line voltage wires must have copper conductors of adequate Gauge with 90° C wire insulation.

0 POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE MF802, TO ENSURE PROPER WIRING.

Figure 4 - MF802 Typical 120 VAC Wiring.

From 15 Amps

Breaker

120 VAC IN

NEUT.

HOT

N

E

U

T

10 A.

Fuse

2

1

1

1 2 3 4

MF802-120

Channels 1,2,3,4

3

2 3 4

S2

SF408

V0.2

Microprocessor

S1

4

For Chasing

Place jumper

From 15 Amps

Breaker

120 VAC IN

NEUT.

HOT

N

E

U

T

10 A.

Fuse

6

5

5 6 7 8

Channels 5,6,7,8

6

MF802-120

7 8

7

5 8

-

1

9 VAC

1

Transformer

9 VAC 300 mAmps

120 VAC IN

Same phase as Main feed

Ch: 5,6,7,8 control cable

12302 SW 128th ct,UNIT 105, Miami, Fl. 33186

Tel: 305-969-8442

Fax: 305-969-8675

www.digitallighting.com

Copyright 2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

Digital Lighting Systems

www.digitallighting.com

MF802

8 channel

User's Manual - Page 5

16 Pattern

Fader / Chaser

MF802-220 General Wiring Instructions for 220-240V version.

Wiring Notes

0 DO NOT EXCEED 600 W (2.5 Amps. ) per circuit output @ 240VAC.

0 MF802 Fader packs may be fed by one 15 (maximum) branch circuits and may have up to four separately switched loads.

0 Loads connected to outputs must be dimmable.

0 CAUTION: DO NOT attempt to parallel outputs to increase capacity.

0 Installations must conform to local and/or NEC code requirements.

0 Each load must have its own Neutral wire for full load operation.

0 All line voltage wires must have copper conductors of adequate Gauge with 90° C wire insulation.

0 POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE MF802, TO ENSURE PROPER WIRING.

Figure 5 - MF802 Typical 220 VAC Wiring.

From 15 Amps

Breaker

240 VAC IN

NEUT.

HOT

N

E

U

T

10 A.

Fuse

2

1

1

1 2 3 4

MF802-240

Channels 1,2,3,4

3

2 3 4

S2

SF408

V0.2

Microprocessor

S1

4

For Chasing

Place jumper

From 15 Amps

Breaker

240 VAC IN

NEUT.

HOT

N

E

U

T

10 A.

Fuse

6

5

5 6 7 8

Channels 5,6,7,8

6

MF802-240

7 8

7

5 8

-

1

9 VAC

1

Transformer

9 VAC 300 mAmps

240 VAC IN

Same phase as Main feed

Ch: 5,6,7,8 control cable

12302 SW 128th ct,UNIT 105, Miami, Fl. 33186

Tel: 305-969-8442

Fax: 305-969-8675

www.digitallighting.com

Copyright 2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

Digital Lighting Systems

www.digitallighting.com

MF802

8 channel

User's Manual - Page 6

16 Pattern

MF802-24 0r MF802-12 General Wiring Instructions 24VAC /12VAC

Wiring Notes

0 DO NOT EXCEED 60 W (2.5 Amps. ) per circuit output @ 24VAC. Or 30 W @ 12 VAC

0 MF802 Fader packs may be fed by one 15 (maximum) branch circuits and may have up to four separately switched loads.

With MF802-24 you may use a single 24 VAC-250 VA or better transformer

.With MF802-12 you may use a single 12 VAC-150 VA or better transformer.

Follow transformer's installation & wiring instructions from manufacturer.

Figure 6 - MF802 Typical 12 VAC or 24 VAC Wiring.

Power inputs to transformers should be on the same phase

12VAC or

24VAC

transformer

12 VAC or

24VAC

C

.

O

M

1 2 3 4

12VAC or

24VAC

transformer

12 VAC or

24VAC

10 A.

Fuse

2

MF802-12 or MF802-24

Channels 1,2,3,4

3

10 A.

Fuse

6

5 6 7 8

MF802-12 or MF802-24

Channels 5,6,7,8

7

1 5 6 7 8

1

2 3 4

S2

SF408

V0.2

Microprocessor

S1

4

For Chasing

Place jumper

5 8

-

1 1

Ch: 5,6,7,8 control cable

12302 SW 128th ct,UNIT 105, Miami, Fl. 33186

Tel: 305-969-8442

Fax: 305-969-8675

www.digitallighting.com

Copyright 2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

Digital Lighting Systems

www.digitallighting.com

MF802

8 channel

Figure 7 - MF802 Typical 12 VDC or 24 VDC Wiring.

Common POSITIVE ( Anode ) / Switched Negative (cathode)

User's Manual - Page 7

16 Pattern

12 VDC or

24 VDC

power

Positive

supply

Negative

+

- +

10 A.

Fuse

2

1

1 2 3

4

MF802-12DC or

MF802-24DC

Channels 1,2,3,4

2 3 4

3

12 VDC or

24 VDC

power

Positive

supply

Negative

+

- +

10 A.

Fuse

6

5

5 6 7

8

MF802-12DC or

MF802-24DC

Channels 5,6,7,8

6 7 8

7

1

S2

SF408

V0.2

Microprocessor

S1

4

For Chasing

Place jumper

5 8

-

1 1

Ch: 5,6,7,8 control cable

12302 SW 128th ct,UNIT 105, Miami, Fl. 33186

Tel: 305-969-8442

Fax: 305-969-8675

www.digitallighting.com

Copyright 2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

Digital Lighting Systems

www.digitallighting.com

MF802

8 channel

User's Manual - Page 8

16 Pattern

Fader / Chaser

Controls

The controls consist of two rotary 16-position (0-9 and A-F) selectors. S2 (PATTERN) is used for selecting the desired Fade pattern. Positions 0 will scroll threw the patterns automatically to provide an ever changing light show. The MF802 outputs can be turned to static ON by selecting F. When 0 is selected, the MF802 goes into an automatic pattern change mode. All other positions cause the MF802 to play a single pattern indefinitely. S1 is used to select one of 16 individual Fade rates (Rate).

Minimum speed is achieved by selecting position 0. Speed doubles with each subsequent selector position.

Indicators

LED indicators 1 to 4 indicate the status (On-Dimmed-Off) of their corresponding

Figure 8 - MF802 Indicators and Control Selectors

S2 S1

Rate

Mode

LED’s

1 2 3 4

Output

Indicators

CAUTION

Use a small Screw driver for adjusting selector positions in order to avoid damaging the Selectors slots.

12302 SW 128th ct,UNIT 105, Miami, Fl. 33186

Tel: 305-969-8442

Fax: 305-969-8675

www.digitallighting.com

Copyright 2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

Digital Lighting Systems

www.digitallighting.com

MF802

8 channel

Patterns for MF802

Step 9:

Step 10:

Step 11:

Step 12:

Step 13:

Step 14:

Step 15:

Step 16:

Step 1:

Step 2:

Step 3:

Step 4:

Step 5:

Step 6:

Step 7:

Step 8:

1

Light Fade

Circuits

1 2 3 4 5 6 7 8

5

Dark Bounce

2

Fill & Swipe Forward

6

Dark Fade

3

Fill & Swipe Back

7

Flip-Flop

User's Manual - Page 9

16 Pattern

Fader / Chaser

4

Light Bounce

8

Flash All

KEY:

ON

OFF

12302 SW 128th ct,UNIT 105, Miami, Fl. 33186

Tel: 305-969-8442

Fax: 305-969-8675

www.digitallighting.com

Copyright 2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

Digital Lighting Systems

www.digitallighting.com

Patterns for MF802

Step 9:

Step 10:

Step 11:

Step 12:

Step 13:

Step 14:

Step 15:

Step 16:

Step 1:

Step 2:

Step 3:

Step 4:

Step 5:

Step 6:

Step 7:

Step 8:

9

Flash Light Fade

Circuits

1 2 3 4 5 6 7 8

D

Crawl Forward

E

A

Spring Forward

Crawl Back

B

Spring Back

F

ALL ON

User's Manual - Page 10

16 Pattern

Fader / Chaser

C

Flash Dark Fade

0

AUTO

Automatic Cycle of Patterns 1-F

4 x each then repeat

KEY:

ON

OFF

12302 SW 128th ct,UNIT 105, Miami, Fl. 33186

Tel: 305-969-8442

Fax: 305-969-8675

www.digitallighting.com

Copyright 2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

LIMITED WARRANTY

Digital Lighting Systems, warrants to the purFader that its products have been carefully manufactured and inspected and are warranted to be free from defects of workmanship and materials when used as intended. Any abuse or misuse contrary to normal operation shall void this warranty.

Digital Lighting Systems' obligation under this warranty shall be limited to replacement or repair of any units as shall within one year of date of invoice from Digital Lighting Systems, prove defective; and Digital Lighting Systems shall not be liable for any other damages, whether direct or consequential. The

implied warranties of merchantability and fitness for a particular purpose are limited to the duration of the

expressed warranty. Some states do not allow the exclusion of the limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, you may also have other legal rights which vary from state to state.

Defective merchandise may be returned to Digital Lighting

Systems, prepaid, after prior notification has been given and approval obtained for the return. To obtain prior approval for the return of the defective items, contact your local Digital Lighting

Systems distributor, representative, or:

Digital Lighting Systems, Inc.

Attn: Customer Service Department

12302 SW 128th ct

Miami, FL 33186

(305) 264-8391

Upon request, replacement unit(s) will be shipped as soon as available. Unless immediate shipment of replacement merchandise is requested, Digital Lighting Systems will not ship replacement merchandise until defective merchandise is received, inspected, and determined to be defective.

No labor charges in connection with warranty problems will be reimbursed by Digital Lighting Systems without prior written approval from the factory.

Digital Lighting Systems distributors and representatives have no authority to change this warranty without written permission.

Digital Lighting Systems reserves the right to determine the best method of correcting warranty problems.

Digital Lighting Systems, Inc.

12302 SW 128th ct

Miami, FL 33186 www.digitallighting.com

Tel 305-969-8442

Fax 305-969-8675

Printed in U.S.A.

April 2007

advertisement

Key Features

  • Single-phase AC lighting controller
  • 8 Channel dimming
  • CrossFader/Lighting animation
  • Color Mixing
  • Quick ON/ OFF ( Animation)
  • 16 user-selectable light sequences
  • Adjustable rate (speed)

Frequently Answers and Questions

What is the maximum current per dimmer channel?
2.5 Amperes
What are the different model variations available?
MF802-12, MF802-24, MF802-120, MF802-220, MF802-12DC, MF802-24DC
How many user-selectable light sequences or patterns are available?
16

Related manuals

Download PDF

advertisement