call system
Tried, trusted and respected by users and
installers alike, C-TEC’s 800 Series Call System
is ideal for use in all types of private,
commercial, residential and public sector
buildings. Incorporating two different
disabled persons toilet alarm kits, a wide
range of indicator panels and an extensive array
of system components, it is without doubt
one of the most versatile and reliable
conventional call systems on the market.
Hundreds of applications - suitable for use in hotels,
leisure centres, nursing homes, shops, offices, etc.
Two levels of call - standard (constant tone) and
emergency (intermittent tone).
Hard wired for total reliability - 4 to 6 core
security cable is ideal for most installations.
Optional button or magnetic key reset facilities
(dependent on items purchased).
Wide range of indicator panels covering 1 to 90 zones.
No limit to system size - components can be mixed
and matched to meet the layout and call
communication requirements of virtually any
building - see typical applications diagram for details.
Extensive range of ancillaries including ceiling pulls,
wall-mounting call points, monitoring points,
water resistant alert points, stainless steel call points,
overdoor lights, remote sounders, relays and
call latch modules.
Optional datalogging, paging and infrared staff
attack facilities.
12V d.c. system - simple to install, easy to operate
and highly reliable.
FREE plan marking up and technical advice
service available for larger systems.
Most wall-mounting plastic components fit standard
25mm single or double gang back boxes. Ceiling
pulls and water resistant alert points are surface
mountable.
Extremely cost-effective - all components
normally available ex-stock.
Attractive compact design blends perfectly
into any sort of decor.
All power supplies capable of 12V sealed lead acid
battery charging.
Manufactured in the UK by an ISO 9001 accredited
company with over 20 years’ experience of making
quality life safety and call system products.
Can be used to help building managers and service
providers comply with BS8300, the Disability
Discrimination Act and the Care Standards Act.
WHAT IS AN 800 SERIES CALL SYSTEM?
In its simplest form, an 800 Series Call System: • Allows the general public, a member of staff or a patient to call for assistance;
• Confirms that the call has got through;
• Makes sure the caller is visited; and, if required;
• Allows extra or more urgent assistance to be summoned using an
optional ‘emergency’ call facility.
le
However, the unrivalled flexibility and versatility of the 800 Series Call System
means it can also be used to: -
Ne w s
tainless steel anc
no
i es
r
a
l
l
i
w
a
ila
va
b
• Inform staff that someone is being attacked via an optional infrared
‘staff attack’ facility.
• Monitor storage cupboards, cash offices and stock rooms for unauthorised
access.
• Monitor doorbells, telephones and machinery for activation or failure.
• Send notification of calls to hand-held paging equipment.
• Provide a permanent printed record of all system and staff activity via
optional datalogging equipment.
HOW DOES AN 800 SERIES CALL SYSTEM WORK?
Depending on the type of calling devices used, the
system can be set up to operate as a standard system – on
which standard (constant tone) calls are generated – or
an emergency system – on which standard (constant tone)
and emergency (intermittent tone) calls are generated.
On standard systems:
The user calls for assistance by activating a ceiling pull,
standard call point, monitoring point, water resistant
alert point or infrared ceiling receiver (as fitted). A red
confidence light on the calling device illuminates to
reassure the user that the call has been registered.
At the system’s indicator panel(s), an indicator light
illuminates and a buzzer sounds to inform staff that
someone is in need of assistance. Relevant overdoor
lights, remote sounders and area indicators also operate
(as fitted) to provide additional audible and visual
indication of the call.
A member of staff visits the calling room to assist the
user and resets the calling device to return the system to
normal.
On emergency systems:
In addition to doing everything a standard system does,
a more urgent / extra level of assistance can be
summoned by activating an ‘emergency call’ via an
emergency call point, water resistant alert point or
infrared ceiling receiver (as fitted).
Once activated, the red confidence light on the calling
device will flash to confirm the emergency call has been
registered and the relevant indicator panel light and its
buzzer will flash and sound a more insistent tone to
attract attention. Relevant overdoor lights, remote
sounders and area indicators will also pulse
(as
fitted) to provide additional audible and visual
indication of the emergency call.
WHICH SYSTEM SHOULD YOU CHOOSE?
The type of system required will depend upon the
application and the needs of the user so always check with
the approving authority/client before work commences.
In residential care homes, a standard system is normally
acceptable as the main requirement is for the reset
function to be carried out at the source of the call. In
nursing homes, however, some authorities insist on
standard and emergency call facilities so an emergency
system may be required. In most other applications, such
as shops, leisure centres, hotels and public sector
buildings, the type of system and devices required will
depend almost entirely on what the user wants to
achieve. In most instances, referring to the typical
applications diagram overleaf will help all interested
parties come to a decision on what components should
be purchased.
PLANNING A SYSTEM
The following points should be considered when
designing or planning an 800 Series Call System.
Indicator panels
Indicator panels should be sited internally in a clean dry
area which is readily accessible to staff. Various types
and sizes are available covering 1 to 90 zones. Repeater
panels are also available.
Call Points
Any number of call points (of any kind), reset points and
overdoor lights can be wired onto one zone.
Standard call points (including ceiling pulls and
monitoring points) will work on 800 Series standard and
emergency systems but emergency call points will work
on emergency systems only.
Some emergency call points can generate standard and
emergency calls whereas others, such as water resistant
alert points and stainless steel call points, can be set up
to generate standard or emergency calls (not both).
Two methods of reset are available - button or magnetic
key. Reset buttons are fine for non-secure applications
but reset keys are usually preferred in care
establishments as they help prevent patients
inadvertently cancelling their own calls.
Call points without an on-board reset facility, such as
ceiling pulls, must be reset via a reset point or call point
with an on-board reset facility.
A full list of standard and emergency call points and the
facilities they offer can be found at the back of this leaflet.
Ancillary calling devices
A tail call lead or hand/foot operated pneumatic pad can
be connected to a call point’s remote socket (if fitted) to
generate a standard call. For safety reasons, a standard
call will also be made if the ancillary calling device is
inadvertently pulled from its socket.
Monitoring points
Monitoring points can be used to trigger a standard call if
a fire exit, drug cupboard or storeroom is opened and can
be isolated via an on-board keyswitch if required. They
can also be connected to any device with a normally open
or normally closed switch, such as a pressure mat, allowing
it to operate as a standard call point when activated.
Call latch modules
Call latch modules operate in a similar way to monitoring
points but are smaller (for discreet mounting) and do not
include an onboard reset or isolating facility.
Infrared call points, ceiling receivers and transmitters
To help protect staff against aggressive visitors, distressed
patients or intruders, infrared ceiling receivers and call
points can be used in conjunction with infrared
transmitters to remotely trigger standard and/or
emergency calls. Up to three slave ceiling receivers can
be connected to one master ceiling receiver or infrared
call point to provide additional coverage in large or L
shaped rooms. Infrared transmitters typically provide a
10m line-of-sight transmitting range.
Overdoor lights
Overdoor lights (if fitted) are normally installed outside
rooms to increase call indication levels. If required, up to
four zones can be connected to one overdoor light to
provide area indication (in corridors, etc) with additional
zones connectable via one or more input expanders.
Remote sounders
Up to three switchable or remote sounders can be
connected to an indicator panel’s sounder output to
increase call levels.
Relay units
External strobes, sounders, beacons, etc, can be connected
to any zone or group of zones via a 12V relay unit.
Datalogging and paging
A datalogger can be used to record the date, time, type
and location of every call and reset and is ideal for
verifying that staff have attended to calls and for
analysing response times. Two paging options are also
available - tone only and alphanumeric, the latter of
which must be used in conjunction with a datalogger.
Master reset buttons
Some indicator panels have an optional master reset
button. If enabled, this facility allows standard calls to
be globally cancelled without the source of the call
being investigated. As there is a definite requirement
in most applications for the caller to be visited before
the call is reset, this facility is normally only utilised in
carefully managed staff-to-staff call systems. In most
other instances we recommend this facility is disabled.
Mute buttons
All multi-zone emergency indicator panels are supplied
with an optional mute button. If enabled, this allows
any standard calls on the system to be silenced but
leaves relevant indicator light(s) lit. Although a new call
from a different call point will re-activate the sounders,
to ensure callers are visited we recommend this facility is
used only in very carefully managed systems. Emergency
calls cannot be muted.
800 SERIES
Typical Applications & Wiring Details
call system
CALL
NC807C
CEILING PULL
NC806C
OVERDOOR LIGHT
CALL
NC807C
CEILING PULL
NC802DERM MAGNETIC
RESET EMERGENCY
INFRA-RED CALL POINT
RESET
CALL
ALERT
Extra ceiling
pulls can
be fitted as
required
RESET
RESET
Call
Call
NC806CS
OVERDOOR
LIGHT &
SOUNDER
Call
NC803M
MAGNETIC
RESET KEY
NC312RXC
INFRA-RED
TRANSMITTER
(PUSH FOR CALL)
TAIL CALL LEAD
disabled bedroom
NC809DB
BUTTON
RESET
POINT
IMPORTANT: There is a definite requirement in
nursecall systems for the reset function to be
carried out at the room from which the call is made
NC807C
CEILING
PULL
disabled persons toilet alarms
special requirement room
ALERT
NC807C
CEILING
PULL
NC806C
OVERDOOR
LIGHT
NC802DEB-1/2
BUTTON RESET
EMERGENCY
CALL POINT
NC802DEB-1/2
BUTTON RESET
EMERGENCY
CALL POINT
nursing home
& hospital
call systems
RESET
PRESSURE PAD
ON
ISOLATED
Call
hotel &
guest house
call systems
NC802DB
BUTTON RESET
CALL POINT
CALL
ON
Call
kitchen, restaurant
& conference room
call systems
MUTE
RESET
MUTE
F
U
S
E
RESET
OR
TAIL CALL LEAD
Call
Call
NC944 FOUR
ZONE CALL
CONTROLLER
NC944 FOUR
ZONE CALL
CONTROLLER
NC930 12V 250mA
POWER SUPPLY
staff attack
and call systems
in casualty areas
1 core per zone
& common -Ve
RESET
NC312RXA
INFRA-RED
TRANSMITTER
(PUSH / PULL FOR
EMERGENCY)
DOOR
CONTACTS
NC803M
MAGNETIC
RESET KEY
BED MOVEMENT
DETECTOR
typical nursing home call system
NC809DM
MAGNETIC RESET POINT
CALL
NC302RXC
INFRA-RED MASTER
CEILING RECEIVER
NC899IRR
KEYSWITCH
RESET POINT
RESET
NC803M
MAGNETIC
RESET KEY
simple
rest home
call system
Call
NC812KE / 822KE / 832KE
10, 20 OR 30 ZONE
EMERGENCY MASTER PANEL
P.I.R
SENSOR
to detect patients
wandering about
Datalogging and paging
facilities also available
NC302RXCS
INFRA-RED SLAVE
CEILING RECEIVER
NC894DKB
ISOLATABLE
BUTTON
RESET
MONITORING
POINT
Switch
Fused
Spur
RESET
Call
NC302RXCS
INFRA-RED SLAVE
CEILING RECEIVER
NC302RXC
INFRA-RED MASTER
CEILING RECEIVER
NC806C
OVERDOOR
LIGHT
Small localised system
may be linked to indicate
on larger master panels
RESET
NC811KE / 821KE / 831KE
10, 20 OR 30 ZONE
EMERGENCY REPEATER PANEL
NC806C
OVERDOOR LIGHT
ON
NC802DM
MAGNETIC RESET
CALL POINT
ISOLATED
Call
Up to three slave
ceiling receivers
can be used per
master receiver
Switch
Fused
Spur
NC312RXA
INFRA-RED TRANSMITTER
(PUSH / PULL FOR EMERGENCY)
F
U
S
E
1 core per zone
+ 3 core control
+ 2 core power
NC803M
MAGNETIC
RESET KEY
(pools, saunas, gyms, solariums, etc)
NC806CS
OVERDOOR
LIGHT &
SOUNDER
ON
Switchable and Remote Sounders are
available to increase sound levels
delivery point / goods-in
NC803M MAG. RESET KEY
checkout, till or counter call
NC894DKM ISOLATABLE
MAGNETIC RESET
MONITORING POINT
Standard
burglar
alarm
contacts
changing rooms
NC807C
CEILING PULL
ALERT
RESET
Call
NC809DB BUTTON
RESET POINT
NC889 CALL
LATCH MODULE
Call
door monitoring
NC803M
MAGNETIC
RESET KEY
Call
NC804DE
EMERGENCY
CALL / BUTTON
RESET POINT
(fire exits, access doors, etc – to prevent
unauthorised access and stock shrinkage)
NC807C
CEILING PULL
NC809DB BUTTON
RESET POINT
NC806CS
OVERDOOR
LIGHT &
SOUNDER
Call
available in two ready-to-fit, self-contained kits
(plastic and stainless steel versions available)
F
U
S
E
ON
CALLING
RESET
Call
NC941 SINGLE ZONE CALL
CONTROLLER / 12V PSU
warehouse
& factory
call systems
disabled persons toilet alarms
Switch
Fused
Spur
CALL
first aid
room
RESET
Call
NC802DB BUTTON
RESET CALL POINT
Relay
Activated
Relay Unit
normally open
or normally
closed voltage
free contacts
RESET
ON
ISOLATED
Call
Call
NC883D
12V RELAY
UNIT
NC894DKB ISOLATABLE
BUTTON RESET
MONITORING POINT
EQUIPMENT TO
BE MONITORED
monitoring plant equipment and other machinery
NC806CS OVERDOOR
LIGHT & SOUNDER
RESET
NC951
STANDARD KIT
TO OTHER EQUIPMENT
e.g. strobes, sirens,
beacons, door releases,
etc. (some of which may
require an external PSU)
NC302RXCS
NC899IRR
NC302RXC
KEYSWITCH INFRA-RED MASTER INFRA-RED SLAVE
RESET POINT CEILING RECEIVER CEILING RECEIVER
general surgery
& interview room
call systems
CALL
Call
consultation/interview room
ON
ISOLATED
Door
contacts
ON
ISOLATED
Call
NC312RXA INFRA-RED
TRANSMITTER (PUSH /
PULL FOR EMERGENCY)
NC894DKB
NC806C
ISOLATABLE
OVERDOOR
BUTTON RESET
LIGHT
MONITORING POINT
monitoring fire doors, etc
© C-TEC 1999-2003. Errors and omissions excepted. No responsibility can be accepted by C-TEC for any misinterpretation of the above or for the compliance of the system as a whole. We reserve the right to alter product specifications at our discretion and without prior notice.
CALLING
NC917L CALL PUSH WITH
PROTRUDING BUTTON
NC807C
CEILING PULL
NC899IRR
KEYSWITCH
RESET POINT
NC803M
MAGNETIC
RESET KEY
NC806C/SS S/STEEL
NC802DEM/SS
OVERDOOR LIGHT S/STEEL CALL POINT
PUSH TO CALL
NC915L desk pushes & NC920 wall sockets are also
available for use as discreet panic alarm buttons.
consultation/interview room
ON
ISOLATED
Call
NC302RXC
INFRA-RED
MASTER
CEILING
RECEIVER
NC312RXCA
INFRA-RED TRANSMITTER
(PUSH FOR STANDARD CALL
PULL FOR EMERGENCY)
consultation room/panic systems
patient
toilet
CABLE & WIRING DETAILS
EXTRA LOW VOLTAGE (7/0.2) SECURITY CABLE
RESET
Call
alarm call
systems
Optional 12V 0.3AHr
battery back-up kit
F
U
S
E
RESET
ON
ISOLATED
External
bell push
at delivery
gate or
door
RESET
Call
RESET
Switch
Fused Spur
NC887D
SWITCHABLE
SOUNDER
NC888D
REMOTE
SOUNDER
MUTE
OFF
Call
Call
Call
CALL
Call
Small localised system
may be linked to indicate
on larger master panels
retail, sports
& leisure
call systems
assistance required systems
NC802DEM/SS
S/STEEL
CALL POINT
NC941B 12V BATTERY
BACK-UP KIT
ON
CALLING
NC802DEWS
NC802DEWM
SLAVE WATER MASTER WATER
RESISTANT
RESISTANT
ALERT POINT
ALERT POINT
Call
NC930/SS
STAINLESS STEEL
12V 250mA PSU
(use 1mm2 for +Ve & -Ve)
infra-red staff protection systems
Call
NC944/SS
STAINLESS STEEL
FOUR ZONE CALL
CONTROLLER
1 core per zone
& common -Ve
Typically 4 or 6 core dependent on layout and devices
used (see right).
Multi-core cable can be used to reduce wiring runs
but more joints will result.
We recommend you leave about 20-25% spare cores.
DO NOT use solid core cable as it breaks easily.
220-240V MAINS FEED, e.g. 1mm T&E
OTHER (as specified)
STANDARD CALL POINTS (including ceiling pulls, monitoring points
and standard reset points): Run 1 signal wire per zone plus a common
negative to the nearest panel
EMERGENCY CALL POINTS (including infrared ceiling receivers and
keyswitch reset points): Run 1 signal wire per zone plus a common
negative and a common positive to the nearest panel
OVERDOOR LIGHTS: Connect to the signal wire of the zone being
indicated and to common negative and common positive
REMOTE SOUNDERS: Usually connected directly to an indicator panel
using two cores
INDICATOR PANELS / REPEATERS: Wire as specified in diagram
800 Series Part Numbers & Product Descriptions
DISABLED PERSONS TOILET ALARM KITS
Include everything required for a BS8300 compliant
disabled persons toilet alarm (except cables & fixings)
NC951
Standard disabled WC alarm kit
c/w NC941 call controller, NC807C ceiling
pull, NC806CS overdoor light & sounder,
NC809DB button reset point & WC sticker
NC951/SS
Standard disabled WC alarm kit, s/steel
c/w NC941/SS call controller, NC807C ceiling
pull, NC806CS/SS overdoor light & sounder,
NC809DB/SS button reset point & WC sticker
SINGLE ZONE EMERGENCY INDICATOR PANELS
Indicate standard and emergency calls
NC941
Single zone call controller
OVERDOOR LIGHTS AND SOUNDERS
Can be used to increase call indication levels
NC806C
Overdoor light
NC806CS
Overdoor light & sounder
NC806C/SS Overdoor light, s/steel
NC806CS/SS Overdoor light & sounder, s/steel
NC887D
Switchable sounder
NC888D
Remote sounder
STANDARD CALL POINTS
Generate standard calls only
NC807C
Ceiling pull unit
No on-board reset, no remote socket
NC802DB
NC941/SS
Single zone call controller, s/steel
c/w 12V 250mA PSU & reset button
NC941B
0.3AHr battery backup kit
for use with single zone call controller
4-12 ZONE EMERGENCY INDICATOR PANELS
Indicate standard and emergency calls
NC944
Four zone call controller
c/w mute/reset button, requires 12V PSU
NC944/SS
c/w mute/reset button, requires 12V PSU
12V 250mA PSU
NC930/SS
12V 250mA PSU, s/steel
powers up to 2 x four zone call controllers
powers up to 2 x four zone call controllers
NC941B
12V 1A white boxed PSU
powers up to 3 x four zone call controllers
AC284
Standard call point
NC917L
Standard call push with protruding button
2.1AHr backup battery
No on-board reset, no remote socket
NC802DEWM Master water resistant alert point
magnetic reset, no remote socket
NC802DEWS Slave water resistant alert point
Magnetic reset, no remote socket
STANDARD MONITORING POINTS
Generate standard calls only
NC894DKB Isolatable monitoring Point
Button reset, no remote socket
NC894DKM Isolatable Monitoring Point
Magnetic reset, no remote socket
EMERGENCY CALL POINTS
Generate standard and/or emergency calls (as shown)
NC802DEB-1/2 Emergency call point
Button reset, with remote socket,
can generate standard & emergency calls
NC802DEM
10 Zone Emergency repeater panel
20 Zone Emergency master panel
NC802DEWM Master water resistant alert point
magnetic reset, no remote socket,
can generate standard or emergency
calls (not both)
NC802DEWS
20 Zone Emergency repeater panel
30 Zone Emergency master panel
NC802DEM/SS Stainless steel call point
Magnetic reset, no remote socket,
can generate standard or emergency
calls (not both)
c/w 12V PSU, backup battery & mute button
NC831KE 30 Zone Emergency repeater panel
Larger panels available to order
10-30 ZONE STANDARD INDICATOR PANELS
Indicate standard calls ONLY
NC810K
10 Zone Standard master panel
c/w 12V PSU & reset button
NC811K
NC820K
10 Zone Standard repeater panel
20 Zone Standard master panel
c/w 12V PSU & reset button
NC821K
NC830K
20 Zone Standard repeater panel
30 Zone Standard master panel
c/w 12V PSU & reset button
NC831K
30 Zone Standard repeater panel
Larger panels available to order
Slave water resistant alert point
Max. 10 per master
c/w 12V PSU, backup battery & mute button
NC821KE
NC832KE
Emergency call point
Magnetic reset, with remote socket
can generate standard & emergency calls
c/w 12V PSU, backup battery & mute button
NC811KE
NC822KE
Infrared transmitter
Push for standard call / pull for emergency
NC312RXC
Infrared transmitter
Push for standard call only
NC312BM
Battery module for transmitter
RESET POINTS
NC809DB
Button reset point
NC809DB/SS
Button reset point, s/steel
NC809DM
Magnetic reset point
NC899IRR
Keyswitch reset point
MAGNETIC RESET KEYS
For use with all magnetic call points, monitoring
points and reset points
NC803M/10 10 x magnetic reset keys
NC803M/50 50 x magnetic reset keys
Up to 10 per master
NC802DEM/SS Stainless steel call point
for use with 12V 1A boxed PSU
10-30 ZONE EMERGENCY INDICATOR PANELS
Indicate standard and emergency calls
NC812KE 10 Zone Emergency master panel
Push/pull for emergency call
NC312RXCA
Magnetic reset, with remote socket
0.3AHr battery backup kit
for use with 12V 250mA PSU
NC925B1
NC802DM
Four zone call controller, s/steel
NC930
Standard call point
Button reset, with remote socket
c/w 12V 250mA PSU & reset button
INFRARED TRANSMITTERS
For use with infrared call points & ceiling receivers
NC312RXA Infrared transmitter
NC804DE
Emergency call / reset point
Button reset, no remote socket,
can generate emergency calls only
NC809DEM
Emergency call / reset point
Magnetic reset, no remote socket,
can generate emergency calls only
INFRARED CALL POINTS & CEILING RECEIVERS
Generate standard and/or emergency calls when
triggered by a compatible infrared transmitter
NC302RXC
Infrared master ceiling receiver
No on-board reset, no remote socket
NC302RXCS
Infrared slave ceiling receiver
ANCILLARY CALLING DEVICES
Generate standard call via a call point’s remote socket
NC805C/6
1.8m (6ft) tail call lead
NC805C/14 4.2m (14ft) tail call lead
NC805D
1.2-3.6m (4-12ft) tail call lead
NC805P
Hand/foot pneumatic pad
requires 1 x NC805AS
NC805AS
NC805MD
MISCELLANEOUS 800 SERIES DEVICES
NC899KD Area isolator
can be used to isolate areas/zones
NC884DE
Infrared call point
Button reset, with remote socket
NC802DERM
Infrared call point
Magnetic reset, with remote socket
Emergency 5:1 input expander
can be used to provide area/zonal indication
NC885
Standard 5:1 input expander
can be used to provide area/zonal indication
NC886C
Call latch module
can trigger a call from a n/o or n/c switch
NC883D
12V relay unit
can be used to switch sirens, strobes, etc.
NC848/10 10 x Anti-tamper screws
can be used to secure stainless steel devices
in high risk environments.
DATALOGGING & PAGING EQUIPMENT
DP800KPD Datalogger c/w software & printer
DP800KD Datalogger c/w software, no printer
DP830K
30 zone interface kit
one required per 30 zones on DP800KPD
or DP800KD datalogger
DP874DA Transmitter for alphanumeric pagers
Must be used in conjunction with a
DP800KPD or DP800KD datalogger
DP877A
Alphanumeric display pager, group 1
For other pager groups add B,C,D,E,F,G or H
to the order code
Up to 3 per master.
NC802DERB
Remote air switch for NC805P
Portable movement detector
DP874B/4 Tone only UHF paging transmitter
supplied with one tone-only pager
DP875/4
Extra tone-only pager
Distributed by:
C-TEC
Stephens Way, Wigan,
WN3 6PH. United Kingdom
Tel: +44 (0)1942 322744
Fax: +44 (0)1942 829867
Email: [email protected]
Web: www.c-tec.co.uk
Quality System Certificate No. 176
Assessed to ISO9001 : 1994
Approved Document. No. DNS8002255 Rev 1. The manufacturer of this equipment operates a policy of continuous improvement and reserves the right to alter product specifications at its discretion and without prior notice.
Errors and omissions excepted. No responsibility can be accepted by the manufacturer or distributor of this equipment for any misinterpretation of an instruction or guidance note, or for the compliance of the system as a whole.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement