Below you will find brief information for cellular module Concord 4 600-1053-4-ZX-AT, cellular module Concord 4 600-1053-4-ZX-RG, cellular module Concord 4 600-1053-4-ZX-TM, cellular module Concord 4 600-1053-4-ZX-VZ . This cellular module is used with Concord 4.0 and higher security panel. It communicates with the cellular network wirelessly for remote monitoring and control of the system. The module is powered by the panel battery or an auxiliary 12VDC power supply. It includes a supervised contact input and provides status LEDs for communication and signal strength. In addition, the module supports Z-Wave technology for controlling compatible smart home devices.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
600-1053-4 Concord 4 Cellular Module
Installation Sheet
Part Number
600-1053-4-ZX-AT
600-1053-4-ZX-RG
600-1053-4-ZX-TM
600-1053-4-ZX-VZ
Description
Concord Cellular Module, Alarm.com
HSPA 3G GSM with Z-wave, AT&T
Concord Cellular Module, Alarm.com
HSPA 3G GSM with Z-wave, Rogers
(Canada use only)
Concord Cellular Module, Alarm.com
HSPA 3G GSM with Z-wave, T-Mobile
Concord Cellular Module, Alarm.com
HSPA 3G CDMA with Z-wave, Verizon
Description
The cellular module interfaces with the Concord panel data bus and is powered by the panel battery or an auxiliary 12 VDC power supply. The module can be used on Concord 4.0 and higher. Status LEDs indicate bus and cellular network communications. A supervised zone input allows you to connect a hard-wired contact.
Figure 1 below shows the location of the main module components and Table 1 below describes the component functions.
Figure 1: Components
Table 1: Components
Component
PWR LED
BUS LED
Function
Indicates module power status.
Indicates data bus activity between the panel and module.
AUTO LED
Status LEDs
Indicates module/data transceiver communication.
Indicates communication status with cellular network.
Provides panel and zone wiring connections. Wiring terminals
Antenna connector Antenna connection for snap-in MMCX antenna.
Cellular status LEDs Indicates communication with the cellular network, report errors, and signal strength.
Serial number A 15-digit number. Only the last 10 digits
(after the dash “-“) are used for account activation.
Use the following tips to ensure success with the Alarm.com
Concord cellular module:
•
Make sure you create the customer account on the
Alarm.com dealer website at least 24 hours before installation.
•
Make sure you turn off the Access Code Lock feature.
Note: This feature must be off for the system to communicate with Alarm.com
•
Use the LEDs on the module to check the signal strength before you permanently mount the module.
•
Power the module off the battery, not off the panel.
•
Do a manual phone test to initiate communication (see
“Power up” on page 4).
Account creation
Before installing the Alarm.com cellular module in a Concord system, a new customer account needs to be created with
Alarm.com. We recommend creating the account at least 24
P/N 466-xxxx4429
• REV B • 08Jul13
1
hours in advance of installation to ensure that the radio is activated prior to installation.
To activate an account go to www.alarm.com/dealer and login.
Under the “Customers” heading at the top left of the page click on “Create New Customer”. You will need the following customer information to create the account:
•
Customer Name
•
Customer Address
•
Customer Phone Number
•
Customer E-mail
•
Preferred login name for the customer
•
Alarm.com Module Serial Number
At the end of the account creation process you will be able to print a Welcome Letter for the customer that has their login information and temporary password for the Alarm.com website.
•
Check the signal strength before choosing a location. Do a walking signal strength test by powering the module off the battery directly (connect the GND and +12V terminals).
After 2 minutes, cellular status LED 4 will flash between one and five times, equivalent to the number of bars on a cell phone. We recommend a signal level of two or higher.
• Do not the mount the module inside the panel’s metal enclosure or within 6 ft. (1.8 m) of panel.
•
Avoid mounting the module in areas with excessive metal or electrical wiring, such as furnace or utility rooms.
•
Locate the module near an outside wall, preferably on an upper level.
•
For homes or businesses located in canyons or with hills nearby, it is necessary to place the antenna higher in the building.
Installation
Before you install the system, the module must be activated.
The account creation process automatically activates the module within 24 hours.
The module draws a maximum of 65 mA (continuous) from the panel in power save mode, and 100 mA (continuous) from the panel in idle and connected modes. Do not exceed the panel total output power when using panel power for bus devices and hardwired sensors (refer to the panel documentation).
Use four-conductor, 22 or 18 gauge stranded wire to connect the module to the panel. Table 2 below shows the maximum wire length for each gauge.
Table 2: Maximum wire length
Gauge Maximum wire length to panel
22 gauge
18 gauge
40 ft. (12.2 m)
90 ft. (27.4 m)
You will need the following tools and supplies to install the module:
•
Small blade and Phillips screwdrivers
•
Drill and bits for screws and/or anchors
•
Wire cutter/stripper
•
Four-conductor, 22-gauge or larger stranded wire
•
#6 panhead screws (4 included)
•
Wall anchors (four included)
•
2-Kohm EOL resistor (included)
Use the following guidelines to choose a location for the module:
Caution:
You must be free of static electricity before handling electronic components. Touch a grounded metal surface before touching the circuit board.
To mount the module:
1. Press down on the top of the enclosure cover, remove it, and set it aside.
2. Snap the antenna onto the antenna connector (see
Figure 1 on page 1). To connect the antenna, place one of your thumbs or fingers behind the antenna connector.
With your other hand, press the end of the micro miniature coaxial connector (MMCX) into the antenna connector until you hear a slight click.
3. Place the backplate on the wall at the desired mounting location, check for level, and mark the three mounting holes and the wire access area (see Figure 1 on page 1).
4. To avoid placing unnecessary strain on the antenna connector, which can damage the module, use either of the following orientations shown in Figure 2.
2 600-1053-4 Concord 4 CDMA Module Installation Sheet
Figure 2: Antenna Routing
Loop antenna and feed -OR- back through top of module
Feed antenna through wire access area and into wall
5. Set the backplate aside and drill holes at the mounting and wire access area locations.
6. Use wall anchors where studs are not present and secure the backplate to the wall with the enclosed screws.
Wiring
Figure 3: Wiring connections
Case tamper switch (optional)
If the module is easily accessible, you can add case tamper detection to activate an alarm or trouble (depending on panel programming) when the cover is removed.
Caution:
To prevent damaging the panel or module, you must remove panel AC power and disconnect the backup battery before making or changing wiring connections.
To wire the module:
1. Remove AC panel power and disconnect the backup battery.
2. Wire the module to the panel bus and to the battery terminals for power. (The module can also be powered off the SuperBus 2000 two-amp power supply (600-1019), but should not be powered directly off the panel.)
3. You can connect an input device to the module Z1 and
ZCOM terminals if required.
To install the tamper switch:
1. Slide the reed switch into the plastic holder on the module backplate.
2. Connect a UL-Listed reed switch (with 2 Kohm EOL resistor) to the module zone input or to any unused hardwired input on the panel.
3. Insert the magnet into the nibs on the top cover and press the magnet clip down over the magnet until it clicks into place into the cover.
Figure 4: Case tamper switch
Backplate
Cover
600-1053-4 Concord 4 CDMA Module Installation Sheet
Magnet
Magnet clip
Reed switch
2.0 kohm EOL resistor
3
Power up
You will need to power up the module and panel to start communication between them.
To power up:
1. Verify that all wiring between the panel and module is correct.
2. Connect the backup battery and restore AC power to the panel.
Note: Whenever any module is added or changed, you must remove panel power and reapply it for the panel and module to communicate successfully.
3. Enter installer program mode and turn off the Access
Code Lock feature (in the Security menu).
This must be set to off for the system to communicate with
Alarm.com. The module PWR LED should turn on. After a few seconds, the module BUS and AUTO LEDs should flash to indicate successful communication with the panel.
4. Verify that cellular status LED L1 is not flashing any errors and that LED L4 is flashing at least a level of two.
Otherwise, relocate the module. If LED L1 and LED L4 are not flashing at all, and LED L2 and LED L3 are flashing together, the module is in power save mode and the battery needs to be changed.
5. Do an installer cellular manual phone test (at system touchpad, enter 8, installer code, 3). Disarm the panel by entering 1 <installer code> within 10 seconds of starting the phone test.
Before doing the manual phone test, the bottom red status
LED should be on and the yellow status LED should be flashing. The yellow LED will stay on solid once the manual phone test is completed.
Note: Do not press any system touchpad buttons during the 5 to 8 minutes, or the time will not set. During this time, the keypad will go in and out of programming mode and will beep several times.
•
Off when the module is out of range and not registered with the network.
•
Blinks when the module is registered with the network, but out of range.
Yellow LED
•
On after the first message has been sent by the module and received by Alarm.com.
•
Off until a message has been sent by the module.
•
Blinks when the first message is being sent by the module.
Green LED
•
Off as soon as Alarm.com receives the message from the module (off most of the time).
•
Blinks when the message is being sent by the module.
Table 3 below describes status LED condition patterns.
1
2
Table 3: Status LED condition patterns
Number Red
LED
Yellow
LED
Green
LED
Module condition
Off
On
Off
Off
Off
Off
Not powered up/not working.
In range, first message not sent, not currently sending message.
3
4
5
6
On
On
On
On
Off In range, first message sent, not currently sending message.
Blinks In range, first message sent, currently sending message.
On Blinks Blinks In range, sending first message, currently sending message.
Blinks On Blinks Out of range, first message sent, currently sending message.
7
8
Blinks On Off Out of range, first message sent, not currently sending message.
Blinks Blinks Blinks Out of range, sending first message, currently sending message.
Status LEDs
The status LEDs located on the left side of the module indicate the current signal and the status of the wireless gateway module. The bottom red LED indicates if the module is in range and if it is registered. The yellow and green LEDs indicate the message status. The top LED is not used.
Red LED
•
On when the module is in range and registered with the network.
Cellular status LEDs
The cellular status LEDs are five small LEDs located below the serial number label on the module.
4 600-1053-4 Concord 4 CDMA Module Installation Sheet
Figure 5: Cellular status LEDs
LED L1 (red). Flashes 1 to 8 times in an 8-second interval to indicate specific error conditions. The number of flashes indicates the error number. If there are two or more errors at the same time, the errors will flash one after the other. The
LED will stay off for at least 4 seconds between errors.
Table 4: LED L1 errors
Flashes Error
1 flash Module cannot communicate with the panel. Check wiring between the panel and the module. Make sure the bus wires are not swapped.
2 then 4 flashes
The module provisioning process could not be completed.
2 then 5 flashes
The module provisioning process could not be completed because the module is currently roaming on the carrier
’s network.
3 flashes The module is trying to register on the cellular network. If it persists more than a few minutes, the module is having problems registering. Check LED L4 for signal level. If the signal level is too low, change the mod ule’s location or use a higher gain antenna.
4 flashes The module is registered on the cellular network, but cannot connect with Alarm.com. Contact Alarm.com technical support.
5 flashes The radio portion of the module is not working correctly.
6 flashes This is an error only if it persists for more than a minute.
Otherwise, it is just an indication that the module is fixing an unusual condition regarding communication with the cellular network.
7 flashes Access Code Lock is on. The module cannot do certain operations with the panel. This option should be turned off at the panel (System Programming
– 0003).
8 flashes Contact Alarm.com technical support.
LED L2 (yellow). Flashes with every communication between the module and the panel. Normal pattern calls for a series of quick flashes every 2 seconds in idle mode or every 4 seconds in power save mode. It also occasionally flashes in patterns to indicate Z-wave status. See Table 5 below for a description of various possibilities.
LED L3 (green or yellow). Flashes with every communication between the module and its radio unit in idle mode, and with every communication with Alarm.com in connected mode. In power save mode, this LED flashes in unison with LED L2.
LED L4 (green or yellow). Indicates cellular signal level as a number of flashes (1 to 5). The signal level is updated every 10 seconds. No flashes indicate one of the following:
•
The module is in power save mode or in connected mode.
•
The module is just powering up, or has just exited power save mode.
•
There is no carrier cellular coverage in the area.
In connected mode, the LED toggles on and off.
If LED L4 is continuously flashing, the module provisioning process is in progress. The signal level indication will resume after the process completes.
LED L5 (yellow) Indicates Z-Wave errors. The possible signals and what they indicate is shown in Table 5 below
Table 5: Z-wave Status & Error Descriptions
LED
L2
LED
L5
Device Status or
Error
Description
4-blink
2-blink
Add mode (lasts
120 seconds or until a device is added)
Delete mode (lasts
120 seconds or until a device is deleted)
In this mode you can add a device to the local Z-Wave network. Devices cannot be added to a network if they are already a part of a network.
In this mode you can delete a device from a Z-Wave network. A device can only be in one network at a time, and must receive a “delete” command before it can be learned into a new network.
Solid
Solid with one blink
2blink
Add node attempt failed because node already in network (lasts 60 seconds)
No other nodes are in the network
(lasts until a device is added to the network)
5blink
Learn mode error
(lasts 60 seconds)
6blink
Successful add node/remove node/ replication (lasts 60 seconds)
After receiving this signal leave all devices by the cellular module for 1 minute.
Locks must be left next to the module for 4 minutes.
No Home ID present (lasts until the module connects to
Alarm.com and is configured)
The device you attempted to add to a network is already in a network, and must be
“deleted” before it can join a new network.
No devices have been added that can be controlled by the cellular module. See above for instructions on how to add devices.
The device you attempted to add into a Z-Wave network was not successfully added.
When the cellular module first connects to Alarm.com it is configured with a necessary unique network
ID.
600-1053-4 Concord 4 CDMA Module Installation Sheet 5
Module modes
The module modes (states) include:
Idle mode. AC power is up, the battery level is greater than
11.5 volts, and the module is currently not connected to
Alarm.com servers. This is normal for the module and the most common state.
•
LED L1 flashes errors, if any.
•
LED L2 indicates communication with panel.
•
LED L3 indicates communication with radio unit.
•
LED L4 indicates the signal level (1 to 5 bars).
•
LED L5 indicates errors, if any.
Power save mode. The module just powered up, AC power is down, or battery level is less than 11.5 volts. The radio part of the module draws 10 mA in power save mode. It is fully functional and will go into connected mode as soon as a signal needs to be sent. Doing a manual phone test will switch the module into idle mode and update the signal level reading.
•
LED L1 is inactive.
•
LED L2 indicates communication with panel.
•
LED L3 flashes in unison with LED L2.
•
LED L4 is inactive.
•
LED L5 is inactive.
Connected mode. The module is connected to Alarm.com servers and reported an alarm or other condition. The module stays in connected mode for at least 6 minutes after the last message is exchanged. Entering the panel’s Installer
Programming mode will cause the module to go into idle mode.
•
LED L1 flashes errors, if any.
•
LED L2 indicates communication with panel.
•
LED L3 indicates communication with Alarm.com.
•
LED L4 alternates 2 seconds on, then 2 seconds off.
•
LED L5 is inactive.
•
The power LED (the green LED at the top of the module) is not on.
Turn off the panel power and verify that all wiring is correct.
•
Module status LEDs (on the left side of the module) do not turn on immediately after initial power up.
You must wait 5 to 8 minutes after power up for the module to communicate with Alarm.com.
Access Code Lock feature (in panel memory) must be turned off for correct operation.
•
Touchpads/sirens are beeping even though the system is not armed.
Press the touchpad Status button and the panel reports the status issue and stops beeping.
•
The status LEDs (on the left side of the module) are all off.
Verify that there is cellular coverage in the location.
Do a walking signal test. Ensure that the module is correctly powered off the battery.
If the wireless gateway module is powered down for a short period, buffered messages may be received from the cellularnetwork when module power is restored.
The cellular module does support reporting of all touchpad panics, but will not send touchpad numbers along with the cancel report. This module does not support the keypad tamper feature at this time.
Z-Wave devices
Required items for installation
•
Concord panel (software versions 4.0 and higher)
•
Alarm.com cellular module with integrated Z-wave support
•
Z-Wave peripherals to be installed
Sensors 94, 95, and 96
If sensors 94, 95, and 96 are not learned in, after doing a manual phone test, the text for these sensors will display important information for troubleshooting purposes. Alarm.com technical support staff may request this information during service calls.
•
Sensor 96 text displays the IMSI number.
•
Sensor 95 text displays the type of central station reports enabled.
•
Sensor 96 text displays the serial number.
Troubleshooting
Check cellular status LED L1 to see if it is flashing any errors.
See Table 4 on page 5 for descriptions of the errors indicated.
Account creation and system setup
1. Create a new account on the Alarm.com Dealer Site (or swap the module into an existing customer account). Add the appropriate emPower services (Lights, Thermostats, and/or Locks) on the service plan page. (Note that “Light
Automation” refers to X10 and is not compatible with emPower.)
2. Install the Alarm.com Z-Wave-enabled cellular module and gateway, connecting it to the Concord panel.
3. Perform a cellular test at the panel to initiate communication between the module and Alarm.com.
Make sure to install the Alarm.com module and gateway outside the metal can. If it is inside the can, this will negatively impact Z-Wave signal transmission.
6 600-1053-4 Concord 4 CDMA Module Installation Sheet
Figure 2: Z-Wave module overview
Adding z-Wave devices
Make sure the Concord panel is connected to AC power when enrolling Z-Wave devices.
When adding devices, first add the devices closest to the
Alarm.com system, and then move outwards.
Devices must be within 6 ft of the Alarm.com module when adding it to the network, Install each of the Z-Wave peripherals in their d esired locations, following the manufacturer’s instructions. Then follow the instructions to add (include) each device into the Alarm.com module’s network. If a device will not be within 6 ft. of the Alarm.com module in its permanent installation location, include it in the network before installation or use a controller (controllers are not available for locks, see below).
If installing a portable Z-Wave controller, first add the controller to the Alarm.com Z-Wave network using the Concord panel, and then use the portable controller to add the remaining devices to the network while the devices are in their permanent locations. (Locks cannot be added to the controller, and will need to be added by the Alarm.com module.) Devices must be within 6 ft. of the controller if a controller is being used to learn in devices.
Add a Z-
Wave device to the Alarm.com module’s network
(Device Inclusion)
1. Put the Alarm.com module into Z-Wave Add mode.
On the Alarm.com module, press and hold down the Z-
Wave Mode button for a few seconds, until the LED L2 begins flashing a 4-blink pattern to indicate Z-Wave Add mode. (See Figure 2 above) for illustration of how to press the button.)
Or,
Use a portable Z-Wave controller to add devices to the network. (See the section on Controllers for details).
2. Press buttons on the Z-Wave device to add.
Once the module (or controller) is in Z-Wave Add mode, press the appropriate buttons on the Z-Wave device to add it to the network. See Device-specific instructions (or the instructions that came with the device) for more information.
3. Confirm the Z-Wave device is added successfully.
Once the device has been added successfully, the panel will beep, and the yellow LED L2 will become solid and stay solid for 1 minute (allow up to 5 seconds for confirmation once the device has been triggered).
To add another device, repeat the steps above. (You do not need to wait for the solid light to go away before holding down the Alarm.com Z-Wave button to enter Add mode again.
See Table 5 on page 5 or
“Z-Wave Troubleshooting” on page
11 for more information on interpreting the Z-Wave LEDs on the module.
Checking the Devices list with Alarm.com
Once you’ve added the devices, the customer website will automatically update the Devices list (under the emPower tab) within about 2 minutes of the last device being added. (To manually trigger the update sooner, you can perform a cellular phone test at the panel.) You can also view the Z-Wave devices through the Alarm.com Dealer website by pulling up the customer account and clicking on the emPower Devices link in the left-hand navigation.
Testing device communication with Alarm.com
Once the Z-Wave devices have been installed in their permanent locations and are displayed in the device list on
Alarm.com, we recommend sending a remote command to each device (e.g., turn on a light; adjust the target temperature
600-1053-4 Concord 4 CDMA Module Installation Sheet 7
at a thermostat) to verify that it is successfully communicating with the Alarm.com module.
If you are onsite at the customer location and do not have access to the website, you can also check communication using the Z-Wave LED L2. When the Alarm.com module is in
Normal mode it is by default off, but issues a single flash whenever it receives a message from a device in its own Z-
Wave network. if a device is next to the panel, you can use this feature to test whether or not the device is currently installed on the Alarm.com Z-Wave network, and whether or not it is communicating properly.
To check communication between a Z-Wave device and the Alarm.com module:
1. Ensure that the Z-Wave device is powered on, and then press the same button you would use if you were trying to add it to a network (check the device’s installation instructions if you are unsure which button to press).
2. The LED L2 on the module will issue a quick single flash to indicate it has heard the signal form the device. If theLED L2 does not flash when the device’s button is pressed, this is most likely because of one of the following: a) the device is not in the Alarm.com module’s Z-Wave network; b) it is out of direct communication range form the Alarm.com module; or c) the device is not powered on or working properly.
Deleting a Z-Wave device (Device Exclusion)
You can enter Delete mode to:
•
Delete a Z-
Wave device from the Alarm.com module’s Z-
Wave network if you no longer want the device in the network (e.g., if it is no longer in use).
•
Delete a Z-Wave device from a different network so that it can then be added into the Alarm.com network. (A given
Z-Wave device and only be assigned to one Z-Wave network at a time. If it is already assigned to one network, it needs to be deleted from one network before it can be added to another network.)
Whether you are deleting a device from the Alarm.com module’s Z-Wave network or another Z-Wave network, the steps are the same.
1. Put the Alarm.com module into Z-Wave Add mode.
On the Alarm.com module, press and hold down the Z-
Wave Mode button to enter Add mode (4-blink pattern on the LED L2). Once in Add mode, press and hold down the
Z-Wave Mode button again until the LED L2 begins flashing a 2-blink pattern to indicate Z-Wave Delete mode.
(See Figure 2 on page 7 for illustration of how to press the button.)
2. Press buttons on the Z-Wave device to delete.
Once the module (or controller) is in Z-Wave Delete mode, press the appropriate buttons on the Z-Wave device to delete it from the network. See Device-specific instructions
(or the instructions that came with the device) for more information.
3. Confirm the Z-Wave device was deleted successfully.
4. Once the device has been deleted successfully, the panel will beep, and the yellow LED L2 on the Alarm.com module’s Z-Wave board will become solid and stay solid for 1 minute (allow up to 5 seconds for confirmation once the device has been triggered).
If a device is not longer functioning, you can also delete it through the Device Automation page on the Alarm.com Dealer website. Send a remote command to the device and wait a few minutes for the command to register as failed. The failed device will have a remote node link next to it.
emPower on the Alarm.com Dealer website
Through the Alarm.com Dealer Website you can modify the emPower service plan, view the Z-Wave device list, and order emPower modules and devices. To add or remove emPower features from your customer’s service plan, go to the customer’s service plan page and check the features (lights, locks, thermostat, or the energy package - lights and thermostat) that you would like to add/remove. To view a list of your customer’s Z-Wave devices, pull up their account and click the “emPower Devices” link.
Device-specific instructions
Controllers
Advanced Remote Controller
Note: if a controller will be used with the system, Alarm.com recommends adding it before the rest of the Z-Wave devices.
Refer to the instructions that came with your controller for more information on controller features and operation.
To add the controller to the security panel (system):
1. Enter your panel into Add mode.
2. With the controller close to your panel, press and hold the
Setup button on the controller until the controller screen displays “Lights Setup”.
3. Use the arrow buttons to scro ll until you see “Transfer” on the controller screen. Press the OK button.
4.
The controller screen should now display “Primary”. Use the arrow buttons to scroll until you see “Receive”.
5. Press the OK button. The controller screen should display
“Receiving”.
6.
The controller screen will briefly display “Success” after the controller has been successfully included into the panel.
To add a light module to the system using the controller:
1. Press and hold the Setup button on the controller until the screen displays “Light Setup”. Press the OK button.
2.
The controller screen should now display “Add”. Press the
OK button.
3. The controller screen should now disp lay “To Network”.
4.
Use the arrow buttons to scroll until you see “To a Key” and then press the OK button.
5. Press a number key 1 to 9 or Setup (Shift) and a number key for numbers 10 to 18.
6. Press the OK button and the screen should now display
“Setup Waiting”.
8 600-1053-4 Concord 4 CDMA Module Installation Sheet
7. Double-click the button on the light module. The controller screen will briefly display “Success” to confirm you have added the device to the controller key and system network.
Note: To add a light module using the controller without adding it to a specific number key on the controller, skip steps 4 and 5.
To add a thermostat to the system using the controller:
1. Press and hold the Setup button on the controller until the screen displays “Light Setup”.
2. Use the arrow buttons to scroll until the screen displays
“Thermostat”. Press the OK button.
3.
The screen should now display “Add”. Press the OK button.
4. The screen should now display “Setup Waiting”. Follow the device-specific directions for the thermostat you are adding to the system to trigger it. The controller screen will display “Success” to confirm you have successfully added it to the system network.
To remove a light module from the system network using the controller:
1. Press and hold the Setup button on the controller until the screen displays “Light Setup”. Press the OK button.
2. The controller screen should now di splay “Add”. Use the arrow buttons to scroll until you see “Delete”. Press the
OK button.
3. Double-click the button on the light module. The controller screen will briefly display “Success” to confirm you have removed the device from the controller key and system network.
To remove the thermostat from the system network using the controller:
1. Press and hold the Setup button on the controller until the screen displays “Light Setup”. Press the OK button.
2. Use the arrow buttons to scroll until the screen displays
“Thermostat”. Press the OK button.
3.
The controller screen should now display “Add”. Use the arrow buttons to scroll until you see “Delete”. Press the
OK button. The screen should now display “Setup
Waiting”.
4. Follow the device-specific directions for the thermostat that you are removing from the system to trigger it.. The controller screen will briefly display “Success” to confirm you have removed it from the system network.
To delete the controller from the security panel (system):
1. Enter your panel into Delete mode.
2.
Follow steps 2 to 5 in the instructions for “To add the controller to the security panel (system):
” on page 8.
3.
The controller screen will briefly display “Success” after the controller has been successfully deleted from the panel.
Lights and appliances
Plug-in Lamp Module or Plug-in Fluorescent
Light/Appliance Module
1. Plug in the device.
2. Enter Add mode on the security panel.
3. To add the device, double-click the button in the middle of the light or appliance module. (If there is no beep at the panel confirming successful enrollment of the device, try pressing the button again.)
Tips
•
Lamp modules cannot be used with compact fluorescent bulbs (CFBs). Use appliance modules instead.
•
Make sure the lamp to be controlled is plugged into the Z-
Wave side of the module (indicated by the Z-Wave logo).
•
We recommend using a non-switched outlet for the module. If using an outlet controlled by a switch, make sure the outlet is switched on before sending light commands.
•
Keep lamps switch on to allow control through the Z-Wave module, Alarm.com website, and mobile applications.
•
Control dimming of lamp modules by pressing and holding the button on the module, or through the Alarm.com website
In-Wall Dimmer Light Switch or In-Wall On/Off Light Switch
1. Follow the provided directions to install the device and ensure that it functions properly with manual on/off control.
2. Enter Add mode on the security panel.
3. To add the device, turn on and turn off the light switch. (If there is no beep at the panel confirming successful enrollment of the device, try turning the device on and off again.)
Tips
•
Dimmer switches and on/off switches cannot be interchanged. Use the appropriate type of switch.
•
If it is not practical to move the security panel 3 to 6 ft. to the device, consider investing in a controller for installations.
In-Wall Outlet Receptacle
1. Follow the provided directions to install the device and ensure that it functions properly with manual control.
2. Enter Add mode on the security panel.
3. To add the device, double-click the button in the middle of the outlet. (If there is no beep at the panel confirming successful enrollment of the device, try double-clicking the button again.)
Tips
•
If it is not practical to move the security panel 3 to 6 ft. to the device, consider investing in a controller for installations.
•
We recommend using a non-switched outlet for the Z-
Wave outlet. If using a switch outlet, make sure the outlet is switched on before sending commands.
600-1053-4 Concord 4 CDMA Module Installation Sheet 9
•
Only the lower outlet is controlled by Z-Wave. Ensure you are plugging devices into the lower outlet while testing if the outlet works for Z-Wave control. The opposite is true if the device is installed upside down.
Locks
Note: If the security panel cannot be taken to within 6 ft. of the lock installation location, add the lock to the system first as directed beginning in step 2. (You will need to connect the battery pack to the keypad before attempting to perform these steps.)
Tips
•
Before removing old locks or beginning installation, check the layout of the door to make sure the new lock will not conflict with existing hardware.
•
Contact a locksmith if you experience difficulties removing old hardware or installing the new lock.
•
Send user codes to the lock (via the customer website - see step 4) before leaving the property. Alarm.com does not recommend programming codes locally via the lock keypad - all codes should be programmed through the
Alarm.com interface.
•
Ask your customer to save the programming code that comes with the lock (Schlage only). This will be convenient to have if they ever have issues in the future.
Schlage lever lock or Schlage deadbolt
1. Follow the instructions included with the lock. When prompted to continue setup online, do the following steps to program the lock into the Concord panel.
2. Enter Add mode on the security panel.
3. On the lock keypad, enter the six-digit programming code
(given by Schlage), then press the Schlage button, followed by 0. The Schlage button will flash green
(Figure 3 below).
Note: Wait until the light flashes green before disrupting the lock or panel. Failure to do so will result in lock malfunctions.
Figure 3: Schlage lock
1.
Enter the panel into Delete mode (see “Deleting a Z-Wave device (Device Exclusion)
” on page 8).
2. Enter the six-digit programming code on the keypad and wait for three orange lights and three beeps.
3. Press the Schlage button and then 0 on the keypad. Wait for three orange lights and three beeps.
4. Wait for all lights to stop blinking. You should now be able to enroll the lock normally by repeating the steps shown above (after re-entering Add mode).
Kwikset deadbolt
1. Follow all instructions provided to install the lock onto the door and double-check that the programmable keypad lock works.
2. Enter the panel into Add mode.
3.
To trigger the lock to add it, press button “B” (Figure 4 below).
Note: Wait until the red light (under the paper next to button “B”) stops flashing before disrupting the lock or panel. Failure to do so will result in lock malfunctions.
4. Login online to the customer account at www.Alarm.com to select which user codes are allowed to use this lock. To do this, go to the emPower then Locks tab. On the User
Codes table, you will see a column labeled Lock Access.
Check the box of the lock you want to allow each user code to access.
Figure 4: Lock trigger button
4. Login online to the customer account at www.alarm.com to select which user codes are allowed to use this lock. To do this, go to the emPower then Locks tab. On the User
Code table, you will see a column labeled Lock Access.
Check the box of the lock you want to allow each user code to access.
Tip
If you observe a red blinking light at the end of the installation keystrokes instead of green, follow these instructions:
Thermostats
Tips
•
The new thermostat should be placed in the same location as the original thermostat unless an HVAC professional approves the new location.
•
Learn the thermostat into your emPower network while it is powered using the power source (AC power vs. battery power) it will use during regular use after installation.
UTC Z-Wave Thermostat
1.
Follow the manufacturer’s instructions to install the thermostat.
2. Enter Add mode on your panel.
3. Under the top cover of the thermostat, press the black
Mate button located in the upper right hand side.
Note
: The thermostat should be connected to AC before it is learned into the network.
10 600-1053-4 Concord 4 CDMA Module Installation Sheet
Trane Remote Energy Management Thermostat
Note: The Trane thermostat requires a 24 VAC common wire to power the thermostat. Before beginning installation, verify the HVAC system has a common wire or contact a qualified
HVAC technician. If the security panel cannot be taken to within 6 ft of the thermostat installation location and you do not have a portable controller, power the thermostat temporarily using a 24 volt transformer and add the thermostat to the system as described in steps 2 and 3 before installing the thermostat.
1. Follow the instructions included with the thermostat through step 19.
2. Instead of step 20, enter Add mode on your panel.
3. Hit the Menu button on the thermostat panel. Scroll down to Z-Wave Install and press Select (Figure 5 below). Press the Yes button to enroll the thermostat.
Figure 5: Trane thermostat
Tip
Verify the enrollment of the thermostat. Scroll down to
Thermostat Info and press the Select button. Look at the number listed after ZNID. If the number listed is anything other than 000, the thermostat was successfully enrolled. If the number listed is 000, then the thermostat has not been successfully enrolled. Try enrollment again or verify that the thermostat is not currently part of another network.
Figure 6: Verify enrollment
Z-Wave Troubleshooting
Device not added successfully
If there is an error, or the two-minute time limit expires when adding a device, LED L5 will issue a 5-blink, and the LED L2 will never light up to indicate that the device was added successfully.
Try the following troubleshooting steps:
•
The device may already be part of a Z-Wave network
(whether or not you have learned the device into a network or not, the manufacturer may have tested the device and left it learned into another system). Try deleting
(excluding) it from its network and the try adding it again. If you receive a Timeout/Error message when trying to delete the device, the issue is likely range-related.
•
If the device is too far from the Alarm.com module when you are adding it, you may need to move the device closer to the panel (or vice versa) while adding it, or else use a portable controller to add it.
•
Other 900 MHz wireless devices may be interfering with the Z-Wave messages. Try moving or replacing any 900
MHz headsets, cordless phones, baby monitors, wireless speaker extenders, IR remote control extenders, or similar devices.
Increasing wireless range of device network
•
Expand your network in pairs:
If a device has been added successfully but does not appear to be communicating reliably with the system, it may be necessary to place another Z-
Wave device (that’s already on the network) between the panel and the problem device, to serve as a repeater that can relay messages between the two.
We recommend expanding your network in pairs of devices.
More devices allow for multiple Z-Wave communication paths, preventing any one device from becoming a bottleneck in the network.
•
Expand your network using beaming devices:
Locks and battery-powered thermostats enter sleep mode to conserve battery life, and therefore can only communicate directly with the panel or with beaming devices that can send a wake-up message. In general, devices powered off of batteries do not beam, and most (but not all) devices powered off of AC power beam.
Note: Newer light/appliance modules support beaming, but some earlier versions did not. To find out if a given module is beaming-compatible, check the label. The light/appliance plugin module supports beaming if the date code starts with 11 or the version includes the letter a or the letter b.
Lock not securely enrolled
Lock devices must complete a secure enrollment process during addition, which can take up to a minute to complete while the lock is within 6 ft. of the panel. If this process is interrupted before completing, the lock will not function properly. A warning message will display on the Alarm.com customer site and on the Dealer site that secure enrollment is not complete. The lock should be deleted from the network and re-added, making sure to allow enough time for secure enrollment to complete before disrupting the lock or panel.
No Home ID (6 flashes on Z-Wave LED L5)
This error occurs when the Alarm.com module has not received the Z-
Wave “Home ID”. Usually, this occurs when the module has not yet communicated with Alarm.com since the
Home ID is sent during initial communication. Perform the cellular phone test and confirm that communication between
Alarm.com and the module has been initiated. If the module is already communicating with Alarm.com and this error persists, check that the Z-Wave daughterboard is securely connected to the module and power cycle the unit.
Device already in Network (steady LED L2 with one blink)
The device being added is already part of a Z-Wave network
(whether the existing network or an old network) and cannot be
600-1053-4 Concord 4 CDMA Module Installation Sheet 11
added again. Clear the device by deleting (excluding) it from its network.
Note: The Alarm.com module can be used to delete devices in any network. The device will clear itself and be able to be added to another network. The device’s old network will still list that device as part of its network (but the device will not be able to be controlled by that network) until the device is removed from its old network.
Specifications
Compatibility
Voltage
Inputs
Cellular network
Power/data bus
Concord panels with software versions 4.0 and higher
12 V nominal, 65 mA (continuous) 1600 mA
(instantaneous peaks) maximum from panel battery or auxiliary power supply
One hardwired zone input
1xRTT CDMA Verizon; 3G HSPA AT&T, T-
Mobile or Rogers
One four-wire SuperBus auto addressing power/communication data bus
Indicators One module/panel communication status
LED, one module power LED, one automation LED, five wireless communication status LEDs
5.25 × 4.125 × 1 in. (133 × 105 × 25 mm) Dimensions
Case color
Case material
Belgian gray
High-impact, ABS plastic
Operating temperature 32 to 120ºF (0 to 49ºC)
Storage temperature -30 to 140ºF (-34 to 60ºC)
Relative humidity 90% noncondensing (maximum)
Regulatory information
FCC
Changes or modifications not expressly approved by UTC Fire and Security can void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment in to an outlet on a circuit different from that which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of
20 centimeters between the radiator and your body.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.
This device complies with Industry Canada license-exempt
RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
FCC ID: YL6-143200H5V4 (GSM), YL6-143200C5V4 (CDMA)
IC: 9111A-143200H5V4 (GSM)
Contact information
www.utcfireandsecurity.com
or www.interlogix.com
For customer support, see www.interlogix.com/customersupport
Copyright © 2013 UTC Fire & Security. All rights reserved
12 600-1053-4 Concord 4 CDMA Module Installation Sheet
advertisement
Key Features
- Wireless communication
- Concord 4.0 compatibility
- Z-Wave support
- Supervised contact input
- Status LEDs
- Alarm.com integration
- Power from panel battery or auxiliary 12VDC power supply