advertisement
Xenon™ 1902
Cordless Area-Imaging System
Quick Start Guide
Note: Refer to your user’s guide for information about cleaning your device.
For localized language versions of this document, go to www.honeywellaidc.com
.
Getting Started
Turn off the computer’s power before connecting the base, then power up the computer once the base is fully connected. When the base is connected and powered up, put the scanner in the base to establish a link. The green LED on the base flashes to indicate the scanner’s battery is charging.
Power Supply Assembly (if included)
1
USB Connection
2
Keyboard Wedge Connection
RS232 Serial Port Connection
3
RS485 Connection
Reading Techniques
The view finder projects an aiming beam that should be centered over the bar code, but it can be positioned in any direction for a good read.
Hold the scanner over the bar code, pull the trigger, and center the aiming beam on the bar code.
4
The aiming beam is smaller when the scanner is closer to the code and larger when it is farther from the code. Hold the scanner close to smaller bar codes, and farther away from large bar codes to get a proper read.
If the bar code is highly reflective (e.g., laminated), you may need to tilt the scanner at an angle so the bar code can be scanned.
Note: If the scanner beeps 3 times when scanning a bar code, the link has not been established. If the scanner beeps once, the link has been established.
Standard Product Defaults
The following bar code resets all standard product default settings.
Standard Product Defaults
5
RS485 Interface
The RS485 interface defaults to port 5B. If you have an IBM POS terminal using port 9B, scan the appropriate code below to program the terminal, then power cycle the cash register.
IBM Port 9B HHBCR-1
Interface
IBM Port 9B HHBCR-2
Interface
Note: For additional RS485 interface selections, see the User’s Guide for your product at our website, www.honeywellaidc.com.
6
Keyboard Country
Scan the Program Keyboard Country bar code below, then scan the numeric bar code(s) from
, then the Save bar code to program the keyboard for your country. As a general rule, the following characters are not supported by the scanner for countries other than the United States:
@ | $ # { } [ ] = / ‘ \ < > ~.
Program Keyboard Country
Country Code
Belgium
Denmark
Finland
France 3
Germany/Austria 4
Great Britain 7
8
2
Scan Country Code
1 Italy
Norway
Spain
Switzerland
USA (Default)
6
0
Scan
5
9
10
Save
Note: For a complete list of country codes, see the
User’s Guide for your product at our website, www.honeywellaidc.com.
7
Locked Link
If you link a scanner to a base using the Locked Link
Mode, other scanners are blocked from being linked if they are inadvertently placed into the base. If you do place a different scanner into the base, it will charge the scanner, but the scanner will not be linked.
Locked Link Mode
(Single Scanner)
To use a different scanner, you need to unlink the original scanner by scanning the Unlink Scanner bar code (
Override Locked Scanner
If you need to replace a broken or lost scanner that is linked to a base, scan the Override Locked
Scanner bar code with a new scanner, and place that scanner in the base. The locked link will be overridden; the broken or lost scanner’s link with the base will be removed, and the new scanner will be linked.
Override Locked Scanner
8
Unlinking the Scanner
If the base has a scanner linked to it, that scanner must be unlinked before a new scanner can be linked. Once the previous scanner is unlinked, it will no longer communicate with the base. Scan the
Unlink Scanner bar code to unlink a scanner.
Unlink Scanner
Trigger
The following bar codes will allow you to use the reader in Manual Trigger - Normal Mode (need to press the trigger to read) or Presentation mode (the reader is activated when it “sees” a bar code).
Manual Trigger - Normal
(Default)
Presentation Mode
9
Streaming Presentation™
When in Streaming Presentation mode, the scanner leaves the scan illumination on all the time and continuously searches for bar codes.
Streaming Presentation Mode
Suffix
If you want a carriage return after the bar code, scan the Add CR Suffix bar code. To add a tab after the bar code, scan the Add Tab Suffix bar code. Otherwise, scan the Remove Suffix bar code to remove the suffixes.
Add CR Suffix
Add Tab Suffix
Remove Suffix
10
Add Code ID Prefix to all Symbologies
Scan the following bar code if you wish to add a
Code ID prefix to all symbologies at once.
Add Code ID Prefix to all Symbologies
(Temporary)
Note: For a complete list of Code IDs, see the
User’s Guide for your product at our website, www.honeywellaidc.com.
Function Code Transmit
When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in your User’s
Guide. When the scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted.
Enable
(Default)
Disable
11
Data Format Editor Instructions
The following are abbreviated instructions for entering a data format. For complete instructions refer to your User’s Guide, available at our website, www.honeywellaidc.com.
1. Scan the Enter Data Format symbol.
2. Primary/Alternate Format: scan 0 for Primary
Format
3. Terminal Type: scan 099 for any terminal type
4. Code I.D.: scan 99 for any bar code type
5. Length: scan 9999 for any length bar code.
6. Editor commands: use the Programming Chart that follows.
7. Scan Save to save your entries.
Enter Data Format
Clear All Data Formats
Save
12
Programming Chart
1
0
2
3
4
5
6
7
13
14
8
A
C
E
Save
D
F
9
B
EZConfig
To access additional features for the scanner use
EZConfig, an online configuration software tool, available from our website at www.honeywellaidc.com.
Technical Assistance
If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office:
North America/Canada
Telephone: (800) 782-4263
E-mail: [email protected]
Latin America
Telephone: (803) 835-8000
Telephone: (800) 782-4263
E-mail: [email protected]
Brazil
Telephone: +55 (21) 3535-9100
Fax: +55 (21) 3535-9105
E-mail: [email protected]
Mexico
Telephone: (803) 835-8000
E-mail: [email protected]
Europe, Middle East, and Africa
Telephone: +31 (0) 40 7999 393
Fax: +31 (0) 40 2425 672
E-mail: [email protected]
15
Hong Kong
Telephone: +852-29536436
Fax: +851-2511-3557
E-mail: [email protected]
Singapore
Telephone: +65-6842-7155
Fax: +65-6842-7166
E-mail: [email protected]
China
Telephone: +86 800 828 2803
Fax: +86-512-6762-2560
E-mail: [email protected]
Japan
Telephone: +81-3-3839-8511
Fax: +81-3-3839-8519
E-mail: [email protected]
Online Technical Assistance
You can also access technical assistance online at www.honeywellaidc.com
.
Product Service and Repair
Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a
Return Material Authorization number (RMA #) before returning the product.
16
North America
Telephone: (800) 782-4263
E-mail: [email protected]
Latin America
Telephone: (803) 835-8000
Telephone: (800) 782-4263
Fax: (239) 263-9689
E-mail: [email protected]
Brazil
Telephone: +55 (21) 3535-9100
Fax: +55 (21) 3535-9105
E-mail: [email protected]
Mexico
Telephone: +52 (55) 5203-2100
Fax: +52 (55) 5531-3672
E-mail: [email protected]
Europe, Middle East, and Africa
Telephone: +31 (0) 40 2901 633
Fax: +31 (0) 40 2901 631
E-mail: [email protected]
Hong Kong
Telephone: +852-29536436
Fax: +851-2511-3557
E-mail: [email protected]
Singapore
Telephone: +65-6842-7155
Fax: +65-6842-7166
E-mail: [email protected]
China
Telephone: +86 800 828 2803
17
Fax: +86-512-6762-2560
E-mail: [email protected]
Japan
Telephone: +81-3-3839-8511
Fax: +81-3-3839-8519
E-mail: [email protected]
Online Product Service and
Repair Assistance
You can also access product service and repair assistance online at www.honeywellaidc.com
.
Limited Warranty
Refer to www.honeywellaidc.com/warranty_information for your warranty information.
Disclaimer
Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Honeywell to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
HII shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material.
18
This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of HII.
©2010 Honeywell International Inc. All rights reserved.
Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of their respective owners.
Web Address: www.honeywellaidc.com
19
20
Honeywell Scanning & Mobility
9680 Old Bailes Road
Fort Mill, SC 29707 www.honeywellaidc.com
Crdlss-NG2D-QS Rev A
3/10
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project