PROXIMITY sensors
cordsets
i/o stations
measurement
rfid
interface modules
TURCK’s global support network consists of over 2,700 employees in 25 countries
and 60 exclusive agencies worldwide that strive to meet customer expectations.
Our sales, support and manufacturing facilities are strategically located across
the world allowing us to respond to local market conditions and deliver customer
specific solutions on a timely basis.
We are a world leader in automation technology with a diverse and broad product
portfolio that provides customer specific applications with high performance,
reliable and cost effective solutions. The synergy in our product portfolio and
customization flexibility are key components of our value proposition.
Our expertise spans across two major industry categories:
Industrial Automation and Process Automation. Each weighs in with its own
unique requirements and methods of conducting business. This market centric
approach ensures that we develop application specific solutions across a variety
of vertical market segments.
custom connectivity
POSITION
NETWORK MEDIA
www.turck.us
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
SOLUTIONS FOR MOBILE EQUIPMENT
Kriss Szkurlatowski
TURCK’s broad line of solutions specially designed for industrial vehicle and mobile
equipment manufacturers has led to product innovations and ease of operations for
customers worldwide. We strive to provide products of exceptional quality that may be
used in harsh applications – and we are able to customize our solutions based on your
specifications.
Our extensive line of solutions includes advanced sensors and encoders for position
detection of booms, outriggers, seats, doors and gates. Level indication may be determined
with TURCK’s line of inclinometers, and our cordsets and junction boxes help you streamline
wiring and connect your components with ease.
Sensing Solutions
Connectivity Solutions
•
•
•
•
• Cordsets
• Junction Boxes
Inductive Position Sensors
Pressure Monitoring Sensors
Angular Position Sensors
Rotary Position Sensors
Features:
• Non-contact technology
provides longer service life
• Able to withstand heavy
shock and vibration
• Extended temperature ranges
• Ease of installation
• Superior noise immunity
• Low operating voltage
• Exceptional sealing
Features:
•
•
•
•
•
Rugged junction box housing
Quick disconnect connectors
Vibration immune connectors
IEC IP 67 and NEMA 6P protection
Excellent abrasion and cut-through
resistant PUR jacketed cordsets
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
TURCK
Solutions For Mobile Equipment
Fire Truck
Ladder Position
• Sensors
Door Position
• Inductive Sensors
Actuators
Position
Ladder Extension
Platform Rotation
Ladder Extension
• Sensors
• Draw Wire Encoders
Platform Rotation
• Sensors
• Encoders
Hydraulic System
Monitoring
Hydraulic System
Monitoring
• Pressure Transducers
Outriggers
• Inductive Sensors
• Draw Wire Encoders
Outriggers
Actuators
• Junction Boxes
• Cordsets
Fork Truck
Steering Position
• Sensors
Position
Seat Position
• Sensors
Mast Height
• Sensors
• Draw Wire
Encoders
Mast Height
Fork Tilt
• Inclinometers
• Sensors
Fork Tilt
Agricultural
Shaft Rotation
• Sensors
Head Position
• Sensors
Shaft Rotation
Extension
• Encoders
Actuators
• Cordsets
Kriss Szkurlatowski
Head Position
4 B1101
Extension
Actuators
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Garbage Truck
Position
Door & Gate Position
• Sensors
Fork Position
• Inclinometers
Hydraulic Ramp Position
• Sensors
Hydraulic Ramp
Position
Actuators
• Junction Boxes
• Cordsets
Actuators
Position
Level Indication
Hydraulic System
Monitoring
Bucket Truck
Turet Rotation
Level Indication
• Inclinometers
Hydraulic System
Monitoring
• Pressure Transducers
Actuators
Boom Position
• Sensors
Turet Rotation
• Sensors
• Encoders
Actuators
• Junction Boxes
• Cordsets
Outriggers
Outriggers
• Inductive Sensors
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
B1101 5
TURCK
Solutions For Mobile Equipment
Inductive Position Sensors_Page 8
High degree of protection
IP 67 plus IP 68 and IP 69k:
DEGREE OF
PROTECTION
• 24 hrs. continuous storage at 70°C
• 24 hrs. continuous storage at -25 C
• 7 days submersion, depth 1 m, 10 temperature changes
from 70°C to -25°C, each temperature for 1 hour
• IP 69k, suitable for high pressure steam-jet
cleaning to DIN 40050-9, following EN 60529
Load dump protection
Test pulse 5 to DIN ISO 7637-2 / SAE J
1113-11 emulates the disconnection pulse
of the battery charging current. This pulse
occurs if a battery is disconnected while the generator is
supplying charging current. This may occur if a battery is
disconnected while the motor is running due to corrosion,
a poor connection or intentionally. In addition, the mobile
equipment sensors passed test pulses 1-4 per
DIN ISO 7637-2 with 12 V and 24 V systems.
Resistance to vibration
and mechanical shock
TURCK mobile equipment sensor series is
ideally equipped to withstand continuous
vibrations and shocks. The sensors are
vibration proof up to 3000 Hz, 20 g, and can
withstand continuous shocks of 100 g in 3 axes.
• EN 60068-2-6 (vibration resistance): 20
g; 10-3000 Hz; 50 cycles; 3 axes
• EN 60068-2-27 (shock resistance): 150 g;
6 ms; 2 g; 3 x each; 3 axes
• EN 60068-2-29 (continuous shock resistance)
100 g; 11 ms, 1/2 sinusoidal; 3 x each; 3 axes
Excellent EMC immunity
The mobile equipment sensor series for
utility vehicles meets more requirements than
stipulated by DIN ISO 7637-2 (conducted and
emitted electrical interference - Part 2: Vehicles
with 12 V or 24 V systems) and DIN EN ISO 14982 for the
severe radiated and line-conducted interference usually
present in vehicles.
Extended temperature range
From -40°C to 85°C or from the polar region to
the Sahara: The extended temperature range
of the sensors allows worldwide use. Even the
radiant heat up to 85°C emitted from motors,
gears or exhaust systems cannot damage these
sensors. Extreme temperature changes as defined by DIN
60068-2-14 (temperature change, -40°C to 85°C; 20 cycles)
are not a problem.
6 B1101
Plug & play with standard
automotive connectors
On request, TURCK can also supply
the sensors with short cables and
connectors, as commonly used with
standard makes in the automotive
sector: Deutsch, Packard and Molex are just some
examples. This makes connection on the prefabricated
cable harness a simple plug & play operation with a proven
connection technology.
Pressure Monitoring Sensors_Page 14
The TURCK pressure transmitters (PTs) are designed to meet
the rugged demands of the hydraulic systems in mobile
applications.
Pressure transmitters have the following features making
them ideal for mobile equipment applications:
•
•
•
•
•
•
•
Fixed range to 8700 psi
No calibration needed
4-20 mA and 0-10 DC outputs
Stainless housing
Robust ceramic element
M12 connection
IP 67
Angular Position Sensors_Page 12
TURCK inclinometer products utilize cutting edge
technology to provide level feedback in a compact,
yet rugged package. Engineered using MEMS (microelectromechanical system) technology, these dual axis
sensors are designed to help keep your equipment within
their safe operating limits in the most challenging, rugged
environments.
• Inclinometers offer 2-axis control
from a single IP 67 housing
• Temperature ranges from -40°C to 85°C
• Robust, fast, stable and precise
• Input voltages from 10 VDC to 30 VDC
• Analog outputs in Logic Control compatible
0.1 – 4.9 VDC and 4-20 mA versions
• Factory level setpoints are easily teachable
to local terrains and equipment setups
• Standard available measuring ranges are
+/- 10°, +/- 45°, +/- 60°, +/- 85°
• Custom ranges are available up to +/- 85°
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Cordset Solutions_Page 18
TURCK’s standard connectivity products can be tailored
specific to your needs. TURCK’s experienced engineers
work to provide you with an application specific solution that
allows you to consolidate all types and styles of automation
connectors.
Examples include:
• Sizes from the sub-miniature M5 to the
35 Amp M40 power connector
• 2 through 28-pin connectors, IP 67 protection
• Custom harness and cable assemblies
• Private wrap labeling
• Color coded wires
• Custom printed snap-in labels
Rugged, Sealed Junction Boxes_Page 20
Consolidate wiring in any application or environment.
TURCK offers a wide array of junction box styles to suit your
application.
• 4, 6 or 8 ports, with or without LEDs
for NPN or PNP sensors
• Integral cable or quick disconnect versions
• M5, M8, M12, 1/2” and 7/8” connector types
• Cast aluminum or plastic fully-encapsulated,
IP 67 and NEMA 6P protection
Rotary Position Sensors_Page 22
TURCK encoder products offer flexible solutions providing
you with the tools to solve even the most demanding
positioning applications. Regardless of your environment,
our engineers are ready to help you choose the right
solutions for your specific requirements.
• Encoders available from -40°C to 90°C and IP 69K
• Heaviest standard bearings in the industry
• Rugged, die cast aluminum and optional
stainless steel housings
• Popular fieldbus networks including
SSI/BiSS, CANopen, and J1939
• Speeds up to 12,000 RPM, standard
• Draw wire lengths up to 40 meters
• M12, M23, MS 6, MS7, and MS10
standard connector types
• Input voltages from 5 VDC to 30 VDC
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
B1101 7
Housing
Part Number
12 mm Embeddable, M12 eurofast ® Connection
Bi 4-EM12E-AP45XLD-H1141
ID Number
Features
T1585000
Sensing
Range (mm)
TURCK
Inductive Position Sensors for Mobile Equipment
Output
4
DC 3-Wire PNP
Bi 4-EM12E-AN45XLD-H1141
T1584003
4
DC 3-Wire NPN
Bi 4-EM12E-AP45XLD
12 mm Embeddable, Potted-in Cable
T1584001
4
DC 3-Wire PNP
Bi 4-EM12E-AN45XLD
T1584004
4
DC 3-Wire NPN
18 mm Embeddable, M12 eurofast Connection
Bi 8-EM18-AP45XLD-H1141
T1584010
8
DC 3-Wire PNP
Bi 8-EM18-AN45XLD-H1141
Bi 8-EM18-AP45XLD
18 mm Embeddable, Potted-in Cable
Bi 8-EM18-AN45XLD
30 mm Embeddable, M12 eurofast Connection
Bi15-EM30-AP45XLD-H1141
T1584017
T1584011
T1584014
• Load Dump
Protection
• Shock Resistant
• EMC Immunity
• Extended
Temperature
Range
• Broader Operating
Voltage
• Improved
Sealing and
Environmental
Protection
• Longer Sensing
Range
T1584020
8
DC 3-Wire NPN
8
DC 3-Wire PNP
8
DC 3-Wire NPN
15
DC 3-Wire PNP
Bi15-EM30-AN45XLD-H1141
T1584024
15
DC 3-Wire NPN
30 mm Embeddable, Potted-in Cable
Bi15-EM30-AP45XLD
T1584021
15
DC 3-Wire PNP
Bi15-EM30-AN45XLD
T1584022
15
DC 3-Wire NPN
8 B1101
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Operating
Current
(mA)
Operating
Temp. (˚C)
Protection
Housing
Face
Power LED
Output LED
Mating
Cord, Cable
Length/
Material
≤2.0
≤200
-40 to +85
IP 68,
IP 69K
SS
PA12
N/A
YE
RK 4T-*/S90
2
≤2.0
≤200
-40 to +85
IP 68,
IP 69K
SS
PA12
N/A
YE
RK 4T-*/S90
1
≤2.0
≤200
-40 to +85
IP 68,
IP 69K
SS
PA12
N/A
YE
2M/TPE
3
≤2.0
≤200
-40 to +85
IP 68,
IP 69K
SS
PA12
N/A
YE
2M/TPE
4
8.4-64 VDC
8.4-64 VDC
Wiring
Diagram #
Switching
Freq. (kHz)
Voltage
Wiring Diagrams
Diagram 1
Diagram 2
8.4-64 VDC
8.4-64 VDC
Diagram 3
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
SS
PA12
N/A
YE
RK 4T-*/S90
2
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
SS
PA12
N/A
YE
RK 4T-*/S90
1
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
SS
PA12
N/A
YE
2M/TPE
3
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
SS
PA12
N/A
YE
2M/TPE
4
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
SS
PA12
N/A
YE
RK 4T-*/S90
2
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
SS
PA12
N/A
YE
RK 4T-*/S90
1
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
SS
PA12
N/A
YE
2M/TPE
3
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
SS
PA12
N/A
YE
2M/TPE
4
8.4-64 VDC
8.4-64 VDC
8.4-64 VDC
8.4-64 VDC
Diagram 4
8.4-64 VDC
8.4-64 VDC
8.4-64 VDC
8.4-64 VDC
* Length in meters.
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
B1101 9
Housing
Part Number
Q14 Embeddable, Potted-in Cable
Bi10-Q14-AP45X2LD
ID Number
Features
M1584031
Sensing
Range (mm)
TURCK
Inductive Position Sensors for Mobile Equipment
Output
10
DC 3-Wire PNP
Bi10-Q14-AN45X2LD
M1584032
10
DC 3-Wire NPN
Q20 Embeddable, M12 eurofast ® Connection
Bi20-Q20-AP45X2LD-H1141
Bi20-Q20-AN45X2LD-H1141
Q20 Embeddable, Potted-in Cable
Bi20-Q20-AP45X2LD
M1584040
M1584042
• Load Dump
Protection
• Shock Resistant
• EMC Immunity
• Extended
Temperature
Range
• Broader Operating
Voltage
• Improved
Sealing and
Environmental
Protection
• Longer Sensing
Range
M1584041
20
DC 3-Wire PNP
20
DC 3-Wire NPN
20
DC 3-Wire PNP
Bi20-Q20-AN45X2LD
M1584043
20
DC 3-Wire NPN
10 B1101
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Operating
Temp. (˚C)
Protection
Housing/
Face
Power LED
Output LED
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
PBT
GN
YE
2M/TPE
2
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
PBT
GN
YE
2M/TPE
1
IP 68,
IP 69K
PBT
Wiring
Diagram #
Operating
Current
(mA)
Mating
Cord, Cable
Length/
Material
Switching
Freq. (kHz)
Voltage
Wiring Diagrams
Diagram 1
8.4-64 VDC
Diagram 2
8.4-64 VDC
≤0.5
≤200
-40 to +85
GN
YE
RK 4T-*/S90
3
8.4-64 VDC
Diagram 3
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
PBT
GN
YE
RK 4T-*/S90
4
8.4-64 VDC
Diagram 4
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
PBT
GN
YE
2M/TPE
2
≤0.5
≤200
-40 to +85
IP 68,
IP 69K
PBT
GN
YE
2M/TPE
1
8.4-64 VDC
8.4-64 VDC
* Length in meters.
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
B1101 11
Housing
Part Number
20 mm – Embeddable,
M12 eurofast ® Connection
B2N 10H-Q20L60-2LU3-H1151
M1534006
-10° to +10°
B2N 45H-Q20L60-2LU3-H1151
M1534007
-45° to +45°
B2N 60H-Q20L60-2LU3-H1151
M1534008
20 mm – Embeddable,
M12 eurofast ® Connection
ID Number
Features
Measuring
Range
(Angular °)
TURCK
Angular Position Sensors for Mobile Equipment
-60° to +60°
• Shock Resistant
• EMC Immunity
• Extended
Temperature
Range
• Broad Operating
Voltage
• Robust
Sealing and
Environmental
Protection
• Logic Level
Outputs
B2N 85H-Q20L60-2LU3-H1151
M1534027
B2N 10H-Q20L60-2LI2-H1151
M1534012
B2N 45H-Q20L60-2LI2-H1151
M1534013
B2N 60H-Q20L60-2LI2-H1151
M1534014
-60° to +60°
B2N 85H-Q20L60-2LI2-H1151
M1534032
-85° to +85°
-85° to +85°
-10° to +10°
-45° to +45°
Output
4-Wire DC
Analog Voltage
4-Wire DC
Analog Voltage
4-Wire DC
Analog Voltage
4-Wire DC
Analog Voltage
4-Wire DC
Analog Current
4-Wire DC
Analog Current
4-Wire DC
Analog Current
4-Wire DC
Analog Current
Dual Axis Inclinometer Sensor
The TURCK inclinometer is a dual axis sensor for angular tilt detection. These sensors
feature compact rectangular housings, and may be mounted up to a maximum of
+/- 85 degree angles. Inclinometer sensors may be used in a wide variety of
applications to solve unique feedback requirements where the customer needs to
level platforms, control tilt angle or control a dancer.
The new TURCK inclinometer measures angular tilt in reference to gravity. At the
heart of the TURCK inclinometer is a MEMS (micro-electro-mechanical system) device
that incorporates a micro-electromechanical capacitive element into the sensor that
utilizes two parallel plate electrodes, one stationary and one attached to a springmass system. Movement causes acceleration that produces deflection in the nonstationary electrode. This results in a measurable change in the capacitance between
the two plates that is proportional to the angle of deflection. These signals are
conditioned to provide two voltage outputs (0.1-4.9 VDC) or two current outputs (4-20
mA). The micro board design in the MEMS technology allows for a compact, precise
inclinometer in a very robust, industrialized package. The inclinometer is IP 67 rated,
with a temperature range of -30°C to 70°C. The sensor is also available in the optional
-40°C /S97 option. 12 B1101
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Output
Voltage/
Current
Operating
Temp. (˚C)*
Protection
Housing
Shock
Resistance
Zero Point
Calibration
Teach
Pendant
≤12
0.1-4.9 V
-30 to +70
IP 67
PBT
30 g
(11 ms)
+/- 5˚
VB2-SP4
RK 4.5T-*
/S618
1
≤12
0.1-4.9 V
-30 to +70
IP 67
PBT
30 g
(11 ms)
+/- 15˚
VB2-SP4
RK 4.5T-*
/S618
1
≤12
0.1-4.9 V
-30 to +70
IP 67
PBT
30 g
(11 ms)
+/- 15˚
VB2-SP4
RK 4.5T-*
/S618
1
10-30 VDC
10-30 VDC
10-30 VDC
Mating
Cordset
Wiring
Diagram #
Output
Recovery
Time (ms)
Voltage
Wiring Diagrams
Diagram 1
Diagram 2
≤12
0.1-4.9 V
-30 to +70
IP 67
PBT
30 g
(11 ms)
+/- 15˚
VB2-SP4
RK 4.5T-*
/S618
1
≤12
4-20 mA
-30 to +70
IP 67
PBT
30 g
(11 ms)
+/- 5˚
VB2-SP4
RK 4.5T-*
/S618
2
≤12
4-20 mA
-30 to +70
IP 67
PBT
30 g
(11 ms)
+/- 15˚
VB2-SP4
RK 4.5T-*
/S618
2
≤12
4-20 mA
-30 to +70
IP 67
PBT
30 g
(11 ms)
+/- 15˚
VB2-SP4
RK 4.5T-*
/S618
2
≤12
4-20 mA
-30 to +70
IP 67
PBT
30 g
(11 ms)
+/- 15˚
VB2-SP4
RK 4.5T-*
/S618
2
10-30 VDC
10-30 VDC
10-30 VDC
10-30 VDC
10-30 VDC
Note: Operating temperature of -40°C available with /S97 option.
* Length in meters.
Zero Setpoint Teach Function
The zero point, or level reference, of the inclinometer may be reset to the unique grade
of your application. Depending on the model, it is adjustable up to +/- 15 degrees from
the factory setting of absolute horizon level. This allows you to effectively shift the
sensing window to accommodate slightly non-level rest positions of your equipment,
such as the difference between an empty and a loaded dump truck. We offer a
teaching pendant to make this a simple, single push-button task.
Optional Teaching Pendant: VB2-SP4
Inclinometer Teach Range Example : B2N 10H-Q20L60-2LU3-H1151
-15°
-5°
0°
-5°
+5°
-10°
0°
-5°
+10°
Factory Setting
0°
+5° +15°
+5°
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
B1101 13
TURCK
Pressure Monitoring Sensors for Mobile Equipment
Pressure Transmitter Technical Information
Specifications:
Ambient Temperature . . . . -40°C to +85°C (-40°F to +185°F)
Medium Temperature. . . . . -40°C to +150°C (-40°F to +302°F)
Current Consumption . . . . ≤20 mA
Dynamic Response . . . . . . <2 ms
Short-Circuit Protection . . Yes
Reverse Polarity
Protection. . . . . . . . . . . . . . Yes
Enclosure Rating . . . . . . . . IP 67
Housing Material . . . . . . . . Stainless Steel 1.430 (AISI 303) / PBT
Shock Resistance . . . . . . . 75 G, 11 ms per IEC 68-2-27
Vibration Resistance . . . . . 20 G, 15 mm per IEC 68-2-6
Zero Shift. . . . . . . . . . . . . . . <±0.015% of measuring range / °C
Span Shift. . . . . . . . . . . . . . <±0.015% of measuring range / °C
Voltage Output. . . . . . . . . . >10 k Ω/ <100 nF
Current Output. . . . . . . . . . ≤
supply voltage
0.02 A
= Ohm
Material:
Housing. . . . . . . . . . . . . . . . 303 Stainless Steel/PBT
Sensing Element. . . . . . . . . AL203 Ceramic
Media Stop. . . . . . . . . . . . . PPS
Cable Connector . . . . . . . . 303 Stainless Steel / PBT
Pressure Connection. . . . . 303 Stainless Steel
O-ring Seal . . . . . . . . . . . . . Viton
PT...LI3
(scaled in bar)
PT...LI3
(scaled in psi)
Output
4-20 mA Loop Powered
4-20 mA Loop Powered
0-10 V
0-10 V
Voltage
8-33 VDC
8-33 VDC
11.4-33 VDC
11.4-33 VDC
Accuracy** (Full Scale)
Mating Cordset
PT...LU2
(scaled in bar)
PT...LU2
(scaled in psi)
≤0.3%
≤0.5%
≤0.3%
≤0.5%
RK 4T-*/S618
RK 4T-*/S618
RK 4T-*/S618
RK 4T-*/S618
Wiring Diagrams
*Length in meters.
**Total of linearity, hysteresis and repeatability.
14 B1101
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
ID Number
Scaled
Pressure Range
Allowable Over
Pressure (bar)
Description
Part Number
Gauge Pressure Transmitter, 1/4 Male NPT Connection,
Scaled in PSI, 4-20 mA Output
PT-30HG-13-LI3-H1131
PT15psig-13-LI3-H1131
PT30psig-13-LI3-H1131
PT60psig-13-LI3-H1131
PT100psig-13-LI3-H1131
PT200psig-13-LI3-H1131
PT300psig-13-LI3-H1131
PT500psig-13-LI3-H1131
PT750psig-13-LI3-H1131
PT1000psig-13-LI3-H1131
PT2000psig-13-LI3-H1131
PT3000psig-13-LI3-H1131
PT5000psig-13-LI3-H1131
PT7500psig-13-LI3-H1131
H6831455
H6831456
H6831457
H6831458
H6831459
H6831460
H6831461
H6831462
H6831463
H6831464
H6831465
H6831466
H6831467
H6831468
0 to -30 inHg
0 to 15 psi
0 to 30 psi
0 to 60 psi
0 to 100 psi
0 to 200 psi
0 to 300 psi
0 to 500 psi
0 to 750 psi
0 to 1000 psi
0 to 2000 psi
0 to 3000 psi
0 to 5000 psi
0 to 7500 psi
60 inHg
45 psi
90 psi
150 psi
250 psi
500 psi
750 psi
1250 psi
1875 psi
2500 psi
5000 psi
7500 psi
12,500 psi
13,050 psi
Gauge Pressure Transmitter, 1/4 Male NPT Connection,
Scaled in PSI, 0-10 V Output
PT-30HG-13-LU2-H1131
PT15psig-13-LU2-H1131
PT30psig-13-LU2-H1131
PT60psig-13-LU2-H1131
PT100psig-13-LU2-H1131
PT200psig-13-LU2-H1131
PT300psig-13-LU2-H1131
PT500psig-13-LU2-H1131
PT750psig-13-LU2-H1131
PT1000psig-13-LU2-H1131
PT2000psig-13-LU2-H1131
PT3000psig-13-LU2-H1131
PT5000psig-13-LU2-H1131
PT7500psig-13-LU2-H1131
H6831469
H6831470
H6831471
H6831472
H6831473
H6831474
H6831475
H6831476
H6831477
H6831478
H6831479
H6831480
H6831481
H6831482
0 to 30 inHg
0 to 15 psi
0 to 30 psi
0 to 60 psi
0 to 100 psi
0 to 200 psi
0 to 300 psi
0 to 500 psi
0 to 750 psi
0 to 1000 psi
0 to 2000 psi
0 to 3000 psi
0 to 5000 psi
0 to 7500 psi
60 inHg
45 psi
90 psi
150 psi
250 psi
500 psi
750 psi
1250 psi
1875 psi
2500 psi
5000 psi
7500 psi
12,500 psi
13,050 psi
See page 14 for technical information.
Conversion: 1 bar = 14.5038 psi
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
B1101 15
TURCK
Pressure Monitoring Sensors for Mobile Equipment
ID Number
Scaled Pressure
Range (bar)
Allowable Over
Pressure (bar)
Description
Part Number
Gauge Pressure Transmitter, 4-20 mA Output,
1/4 Male NPT Connection, Scaled in bar
PT01VR-13-LI3-H1131
PT001R-13-LI3-H1131
PT002R-13-LI3-H1131
PT003R-13-LI3-H1131
PT004R-13-LI3-H1131
PT006R-13-LI3-H1131
PT010R-13-LI3-H1131
PT016R-13-LI3-H1131
PT025R-13-LI3-H1131
PT040R-13-LI3-H1131
PT060R-13-LI3-H1131
PT100R-13-LI3-H1131
PT160R-13-LI3-H1131
PT250R-13-LI3-H1131
PT400R-13-LI3-H1131
PT600R-13-LI3-H1131
H6831496
H6831497
H6831498
H6831499
H6831500
H6831501
H6831502
H6831503
H6831504
H6831505
H6831506
H6831507
H6831508
H6831509
H6831510
H6831511
-1 to 0
0 to 1
0 to 1.6
0 to 2.5
0 to 4
0 to 6
0 to 10
0 to 16
0 to 25
0 to 40
0 to 60
0 to 100
0 to 160
0 to 250
0 to 400
0 to 600
3
3
4.8
7.5
12
15
25
40
62.5
100
150
250
400
625
900
900
Gauge Pressure Transmitter, 0-10 V Output,
1/4 Male NPT Connection, Scaled in bar
PT01VR-13-LU2-H1131
PT001R-13-LU2-H1131
PT002R-13-LU2-H1131
PT003R-13-LU2-H1131
PT004R-13-LU2-H1131
PT006R-13-LU2-H1131
PT010R-13-LU2-H1131
PT016R-13-LU2-H1131
PT025R-13-LU2-H1131
PT040R-13-LU2-H1131
PT060R-13-LU2-H1131
PT100R-13-LU2-H1131
PT160R-13-LU2-H1131
PT250R-13-LU2-H1131
PT400R-13-LU2-H1131
PT600R-13-LU2-H1131
H6831512
H6831513
H6831514
H6831515
H6831516
H6831517
H6831518
H6831519
H6831520
H6831521
H6831522
H6831523
H6831524
H6831525
H6831526
H6831527
-1 to 0
0 to 1
0 to 1.6
0 to 2.5
0 to 4
0 to 6
0 to 10
0 to 16
0 to 25
0 to 40
0 to 60
0 to 100
0 to 160
0 to 250
0 to 400
3
3
4.8
7.5
12
15
25
40
62.5
100
150
250
400
625
900
900
0 to 600
See page 14 for technical information.
Conversion: 1 bar = 14.5038 psi
16 B1101
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Description
Part Number
Gauge Pressure Transmitter, G 1/4 Female Connection,
4-20 mA Output, Scaled in bar
PT01VR-11-LI3-H1131
PT0.5R-11-LI3-H1131
PT001R-11-LI3-H1131
PT002R-11-LI3-H1131
PT003R-11-LI3-H1131
PT004R-11-LI3-H1131
PT006R-11-LI3-H1131
PT010R-11-LI3-H1131
PT016R-11-LI3-H1131
PT025R-11-LI3-H1131
PT040R-11-LI3-H1131
PT060R-11-LI3-H1131
PT100R-11-LI3-H1131
PT160R-11-LI3-H1131
PT250R-11-LI3-H1131
PT400R-11-LI3-H1131
PT600R-11-LI3-H1131
ID Number
Scaled Pressure
Range (bar)
Allowable Over
Pressure (bar)
H6831433
H6831495
H6831434
H6831435
H6831436
H6831437
H6831438
H6831432
H6831439
H6831440
H6831441
H6831442
H6831443
H6831444
H6831445
H6831446
H6831447
-1 to 0
0 to 0.5
0 to 1
0 to 1.6
0 to 2.5
0 to 4
0 to 6
0 to 10
0 to 16
0 to 25
0 to 40
0 to 60
0 to 100
0 to 160
0 to 250
0 to 400
0 to 600
3
1.5
3
4.8
7.5
12
15
25
40
62.5
100
150
250
400
625
900
900
Gauge Pressure Transmitter, G 1/4 Female Connection,
0-10 V Output, Scaled in bar
PT01VR-11-LU2-H1131
PT001R-11-LU2-H1131
PT002R-11-LU2-H1131
PT003R-11-LU2-H1131
PT004R-11-LU2-H1131
PT006R-11-LU2-H1131
PT010R-11-LU2-H1131
PT016R-11-LU2-H1131
PT025R-11-LU2-H1131
PT040R-11-LU2-H1131
PT060R-11-LU2-H1131
PT100R-11-LU2-H1131
PT160R-11-LU2-H1131
PT250R-11-LU2-H1131
PT400R-11-LU2-H1131
PT600R-11-LU2-H1131
H6831454
H6831483
H6831484
H6831485
H6831486
H6831452
H6831487
H6831488
H6831489
H6831490
H6831491
H6831492
H6831453
H6831451
H6831493
H6831494
-1 to 0
0 to 1
0 to 1.6
0 to 2.5
0 to 4
0 to 6
0 to 10
0 to 16
0 to 25
0 to 40
0 to 60
0 to 100
0 to 160
0 to 250
0 to 400
0 to 600
3
3
4.8
7.5
12
15
25
40
62.5
100
150
250
400
625
900
900
Absolute Pressure Transmitter, G 1/4 Female
Connection, 4-20 mA Output, Scaled in bar
PT001A-11-LI3-H1131
PT002A-11-LI3-H1131
PT003A-11-LI3-H1131
H6831449
H6831450
H6831448
0 to 1
0 to 1.6
0 to 2.5
3
4.8
7.5
See page 14 for technical information.
Conversion: 1 bar = 14.5038 psi
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
B1101 17
TURCK
Cordsets for Mobile Equipment
Housing Style
Part Number
Cable
Features
Pinout
4 and 5-Wire M12 eurofast ® Cordsets,
Standard Plug Body
RK 4T-*/S90
RK..
WK 4T-*/S90
AWM PUR Grey
3x20 AWG
105°Ct
250 VAC/300 VDC, 4 A
5.2 mm OD
Cable #RF50518-*M+
WK..
1.
2.
3.
4.
BN
N/C
BU
BK
1.
2.
3.
4.
5.
BN
WH
BU
BK
GY
RS 4T-*/S90
WS 4T-*/S90
RS..
• NEMA 1, 3, 4,
6P and
IEC IP 68
Protection
• Cut/Abrasion
Immune
• Anti-vibration
coupling nut
RK 4.5T-*/S90
WK 4.5T-*/S90
AWM PUR Grey
5x22 AWG
105°C
250 V, 4 A
5.7 mm OD
Cable #RF50649-*M+
WS..
RS 4.5T-*/S90
WS 4.5T-*/S90
* Length in meters. Standard cable lengths are 2, 4, 6, 8 and 10 meters. Consult factory for other lengths.
Standard coupling nut material is nickel plated brass.
See section N of Connectivity catalog for reelfast ® cable information.
+
18 B1101
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Housing Style
Part Number
Cable
Features
Pinout
19-Pin M23 multifast ® Cordsets
CKM..
CKM 19-11-*/S90
CKWM 19-11-*/S90
CKWM..
CSM 19-11-*/S90
CSWM 19-11-*/S90
CSM..
• IEC IP 67
Protection
• Cut/Abrasion
Immune
• Anti-vibration
coupling nut
CKM 19-19-*/S90
CKWM 19-19-*/S90
CSWM..
CSM 19-19-*/S90
3. GY
4. RD/BU
5. GN
6. BU
7. GY/PK
8. WH/GN
12. GN/YE
14. BN/GN
15. WH
16. YE
19. BN
AWM PUR Yellow
3x18, 8x22 AWG
105°C
150 V,
9 A (18 AWG)
2 A (22 AWG)
8.4 mm OD
Cable #RF50718-*M+
1. VT
2. RD
3. GY
4. RD/BU
5. GN
6. BU
7. GY/PK
8. WH/GN
9. WH/YE
10. WH/
GY
11. BK
12. GN/YE
13. YE/BN
14. BN/GN
15. WH
16. YE
17. PK
18. GY/BN
19. BN
AWM PUR Yellow
3x18, 16x22 AWG
105°C
150 V,
9 A (18 AWG)
2 A (22 AWG)
10.4 mm OD
Cable #RF50682-*M+
CSWM 19-19-*/S90
* Length in meters. Standard cable lengths are 5 and 10 meters. Consult factory for other lengths.
Standard coupling nut material is nickel plated brass.
+
See section N of Connectivity catalog for reelfast ® cable information.
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
B1101 19
TURCK
Junction Boxes for Mobile Equipment
Low Profile Junction Boxes with M12 eurofast ® Connections, 4-Port and 8-Port
4-Port, 2 Signals Per Port, 10-48 VDC
Application
Specifications
4-port J-box
2 signals per
port
M23 multifast ®
connector
2 A/port,
10 A total
19-pin
M23 multifast
connector
11 conductors
Mates with
CKM 19-11-*
Pinout
Function
+V
-V
Ground
Port 1, Sig 1
Port 1, Sig 2
Pin / Color
19 / BN
6 / BU
12 / GN / YE
15 / WH
7 / GY / PK
Function
Port 2, Sig 1
Port 2, Sig 2
Port 3, Sig 1
Port 3, Sig 2
Port 4, Sig 1
Port 4, Sig 2
Pin / Color
5/ GN
4 / RD / BU
16 / YE
8 / WH / GN
3 / GY
14 / BN / GN
No LEDs
PNP LED
NPN LED
4MB12Z-5-CS19
4MB12Z-5P3-CS19
4MB12Z-5N3-CS19
No LEDs
PNP LED
NPN LED
8MB12Z-5-CS19
8MB12Z-5P3-CS19
8MB12Z-5N3-CS19
8-Port, 2 Signals Per Port, 10-48 VDC
Application
8-port J-box
2 signals per
port
M23 multifast
connector
Specifications
2 A/port,
10 A total
19-pin
M23 multifast
connector
19 conductors
Mates with
CKM 19-19-*
Pinout
Function
+V
-V
Ground
Port 1, Sig 1
Port 1, Sig 2
Port 2, Sig 1
Port 2, Sig 2
Port 3, Sig 1
Port 3, Sig 2
Pin / Color
19 / BN
6 / BU
12 / GN / YE
15 / WH
7 / GY / PK
5 / GN
4 / RD / BU
16 / YE
8 / WH / GN
Function
Port 4, Sig 1
Port 4, Sig 2
Port 5, Sig 1
Port 5, Sig 2
Port 6, Sig 1
Port 6, Sig 2
Port 7, Sig 1
Port 7, Sig 2
Port 8, Sig 1
Port 8, Sig 2
Pin / Color
3 / GY
14 / BN / GN
17 / PK
9 / WH / YE
2 / RD
13 / YE / BN
11 / BK
10 / WH / GY
1 / VT
18 / GY / BN
Note: Integral cable and side exit connector home run options available
* Length in meters.
Features:
Specifications:
•
•
•
•
Housing:Nylon
Connectors:
M12 eurofast ®: Nylon or PUR, spacings to VDE 0110 Group C
Contacts:
Gold plated brass
Thread Inserts:Nickel plated brass
LED Current:
10 mA maximum at 48 VDC supply voltage (per LED)
Temperature:
-30°C to +80°C (-22°F to +176°F)
Accessories:
VZ 3 closure caps and a VZ 12 label kit included
Recommended Splitter: YB2-FSM 4.5-2FKM 4.5
Dual Output per port
Rugged Plastic Housing
Available with or without LEDs
M23 Quick Disconnect
Homerun Cable
• Threaded M12 Connections
• Corrosive Resistant
• NEMA 1, 3, 4, 6P and IEC IP 67
20 B1101
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Low Profile Junction Boxes with M12 eurofast ® Connections, 4-Port and 8-Port
Dimensions
4-Port Quick Disconnect
8-Port Quick Disconnect
Functional Wiring Diagrams
(PNP LED Version)
2 Signals Per Port
Pinout
(No LED Version)
2 Signals Per Port
Female
Male
5-Pin M12 eurofast
19-Pin M23 multifast ®
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
B1101 21
TURCK
Rotary Position Sensors for Mobile Equipment
Absolute Singleturn Encoder Type T8.2450/T8.2470
Non-contact measuring system with long service life, high reliability,
high resolution, 12 Bit (4096 various positions at 360°)
locked bearing
- 20° to + 85°
temperature
Absolute Singleturn, SSI, shaft T8.2450
Absolute Singleturn, SSI, hollow shaft T8.2470
• Output SSI (12 Bit)
• Rugged cable outlet, high strain
relief thanks to multiple clamping
• Wide range of power supply
• 5 VDC or 8-30 VDC
For complete specifications please visit www.turck.com/SSi
Sendix Absolute, Singleturn Encoder Type T8.3651/T8.3671 and T8.3658/T8.3678
New magnetic singleturn encoder that provides all-round protection thanks to
Safety-Lockplus™ and Sensor-Protect™ technology.
•
•
•
•
- 40° to + 85°
Safety-Lockplus™
temperature
IP 69k
mA, V
high IP value
output
shock resistant
vibration resistant
22 B1101
Output: 4-20 mA, 0-10 V, or CANopen
Wide range of temperature -40° to 85°C
Resolution 12 Bit (4-20 mA, 0-10 V)
Resolution 14 Bit (CANopen)
Sensor-Protect™
Fully encapsulated electronics;
separate mechanical bearing assembly
Safety-Lockplus™
IP 69k protection on the flange side;
robust bearing assemblies with
interlocking bearings; mechanically
protected shaft seal
For complete specifications please visit www.turck.com/Magnetic
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Draw Wire Encoders A50, B80, C120, D135
- 20° to + 85°
wide temperature
range
shock resistant
vibration resistant
IP
high IP value
• Specially designed for demanding applications
• For use with analog sensors (0-10 V,
4-20 mA, potentiometer) or encoders
(Incremental, Absolute, Fieldbus)
• Measurement length from 250-40,000 mm
• High speed
• High acceleration
Dynamic spring traction by means of a
constant force spring, long service life,
approximately 2 million complete cycles.
•
•
•
•
Type D135
Simple wire fixing using clip
Type A50
Quick mounting
Diamond-polished ceramic guide
Titanium anodized aluminium housing
For complete specifications please visit www.turck.com/DrawWire
reverse polarity
protection
Slip Rings
In general, slip rings are used to transmit power,
signal or data from a stationary to a rotating platform.
Advantages and benefits:
Application areas for Slip Rings:
• Rugged design for industrial use
• Modular system construction,
load and signal channels can
be combined selectively
• Long service life and long
maintenance cycles
• Separate signal channels
• Fieldbus signals such as PROFIBUS®,
CANopen, etc. (up to 12 MB)
•
•
•
•
•
•
Packaging machines
Textile machines
Robots and handling equipment
Cranes
Pipeline inspection systems
Video surveillance
(CCTV) equipment
• Amusement park rides
• Bottling plants
• Rotary tables
SR085
SR060
For complete specifications please visit www.turck.com/SlipRings
www.turck.us • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK Inc. Minneapolis, MN 55441
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
B1101 23
TURCK Inc.
3000 Campus Drive
Minneapolis, MN 55441
Phone:(763) 553-7300
Fax: (763) 553-0708
Application Support:
1-800-544-7769
E-mail:[email protected]
www.turck.us
MEXICO
TURCK MEXICO S. DE R.L. DE C.V.
Carr. Saltillo-Zacatecas km 4.5 s/n
Parque Industrial “La Angostura”
Saltillo, COAH. C.P. 25070
Mexico
Phone:+52 (844) 411-6650/46
Fax: +52 (844) 482-6926
Local Toll Free: 01-800-01-88725
E-mail:[email protected]
CANADA
CHARTWELL ELECTRONICS, INC.
140 Duffield Drive
Markham, Ontario
Canada, L6G 1B5
Phone:(905) 513-7100
Fax: (905) 513-7101
Toll Free: 1-877-513-7769
AUSTRALIA
TURCK Australia Pty. Ltd.
Unit 5, 6-7 Gilda Court
Mulgrave, Victoria 3170
Australia
Phone:(+61) 3 9560 9006
Fax: (+61) 3 9560 1620
Local Toll Free: 1300 132566
E-mail:[email protected]
GERMANY
WORLD HEADQUARTERS
Hans TURCK GmbH & Co. KG
Witzlebenstrasse 7
D-45472 Muelheim an der Ruhr
Federal Republic of Germany
Phone:(+49) 208-49 52-0
Fax: (+49) 208-49 52 264
Printed in USA
©2009 by TURCK Inc. All rights reserved. No part of the
publication may be reproduced without written permission.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
www.turck.com
USA
B1101
5/09