datasheet for TIW4X by CONTA-CLIP

datasheet for TIW4X by CONTA-CLIP
15
16
14
17
21
20
19
18
13
12
11
22
23 24
25
26
10
4 5
9
3
6
TELE • Vorarlberger Allee 38 • 1230 Vienna • Austria
Tel. +43 (0)1 614 74 - 0 • Fax +43 (0)1 614 74 - 100
www.tele-online.com
No. Art. 091002
7
TELE - Main Catalogue - 2011 / 2012
Technik braucht Kontrolle: A great deal of research and development has
been undertaken at TELE and it beneits further from its production base
in Austria and a strong team that brings its products to the market. The
company grew with time relays and automation components and the focus
on monitoring technology still characterizes the company today. As a pioneer
and trendsetter, it is able to deliver intelligent solutions for monitoring plants,
factories, buildings and machines and keeping them running.
TELE produces up-to-the-minute monitoring and control equipment that
satisies international standards for worldwide deployment at the highest
levels of quality – from a passion and out of professionalism.
Established in 1963 as a family owned company, the headquarters and
production base in Vienna has generated branches in Germany and Great
Britain and a dense network of more than 60 dealers all over the world. Longstanding customers from all areas of industry and fresh ideas for dificult
tasks have made us what we are today – a reliable and lexible partner.
Here, the striking green design is the external expression of internal values –
quality and innovation constitute the basis for our many years of success and
our orientation towards the future.
8
27
28
MAIN฀CATALOGUE
2011/2012
2
1
Table฀of฀Content
15
US
- About TELE
News
- Highlights from Tele
Page 4
16
14
Page 6
17
21
20
19
18
13
12
TELE฀offers...
11
22
23 24
25
26
10
4 5
9
1. Sensing & Monitoring relays
- Voltage
- Current
- Temperature
- Level
2. Loadmonitors
- True power
- Power factor (cos )
3. Time relays
- Time relays
- Star Delta relays
- Staircase timer
- Emergency light tester
Page 105
4. Monitoring systems and
control units
- WatchDog pro
- Energy management ECO III
- Sequence processor STEP-T8
- Pump Alternator
Page 157
5. Power electronic
- Softstarter
- Braking units
- Thyristor control units
Page 209
6. Switching relays and other
automation components
- Switching relays
- Coupling units
- Safety relays
- Signal converter
- Digital time switches
- Hour meters
- Power supplies
Page 219
7. Accessories
- PowerModules
- Probes
- Current transformers
- Other
Page 249
3
Page 9
Connecting the Dots
Changes, whether social, technological, ecological or economic,
6
deine our evolution at all times.
8
Page 87
People, institutions and businesses are being challenged now
more than ever to not only accept this change but to actively
contribute to shaping it.
7
Clean and intelligent technologies contribute essentially
to eficiently deining products and solutions in the
long-term in order to make our environment a better place to live.
Question the existing
Record trends Anticipate the future.
27
2
Recognize dependencies and make connections.
This is how our ideas evolve
This is how TELE develops products.
Christoph Haase
28
1
Page 254
Index
Page 2
w w w. tel e-o n l i n e. co m
Page 3
US
Günther Haase,
Founder
ERFAHRUNG
EXPERIENCE
Bettina Putz, Customer Service
STANDARDS
TELE has been going strong since 1963. We believe that’s long enough to boast, “We know what we’re doing!” We have the biggest
Over 25% of our turnover is made with products tailored to our customer’s unique speciications. This is quite a large
product range of any provider in the ield of timing and monitoring relays – Worldwide. Like us, all our products are 100% Austrian made.
percentage and is one of our strengths. We have customers in over 60 countries and we take care to develop a special
That is a claim we are very proud of, just as we are proud that we have been the market leader in Austria for decades – by a long shot.
relationship with each one – a relationship based on partner-ship, reliability and always to everyone’s mutual beneit.
We call it our “handshake guarantee” and it is of the utmost importance to us.
GIVE
AND฀
TAKE
OUTLOOK
Dieter Dollansky, SMD Assembly
Aranka Copor, Assembly
Christian Mari, Head of Procurement
“Intelligent solutions with added value for our customers.” Behind this stuffy corporate statement stands nothing
We can tell you today what you can expect from us in the future. We will continue to do what we do best: Support the supply
more than the high standards of over 100 colleagues. We constantly strive to exceed the expectations of our
of electrical energy from creation to consumption and ensure everything runs smoothly along the way. We will focus on the
customers and, well, succeed most of the time. We try to put our all into everything we do. Word of honour.
responsible use of energy and create solutions that encourage us all to use our planet’s resources in a sustainable manner.
No more, no less.
Page 4
Page 5
NEW
Highlights฀from฀TELE
Load monitors
NEW
AUTOMATIC DISCONNECTION DEVICE
NEW
True-off relays D6A,
K3ZA and G2ZA
NEW
Page 6
“The motor as sensor”
Monitoring motors’ efficiency or effective power makes it possible to draw
a number of useful conclusions regarding the state of drives, machines
and installations, and these can often be used to reduce the cost of
maintenance, servicing and downtime.
Benefits and added value are illustrated by means of sample applications such as waste compressors or grinders, agitators, conveyor belts,
ventilation and exhaust systems, machine tools, overhead and gantry
cranes, and centrifugal and reciprocating pumps.
Product portfolio for the safe monitoring of power grids receiving power
from small-scale power stations such as photovoltaic or wind generators.
Internationally certiicated under the national standards of Austria, Germany and Italy.
Although there are a large number of relevant standards, the decision
as to exactly how a grid should be monitored is the responsibility of the
appropriate utility company.
“True OFF”, “relay timing without supply voltage” and similar expressions
all refer to the same simple timing function, but vendors need many years’ experience before they can offer this straightforward function in the
form of a timing relay that is suficiently robust for industrial use. TELE
has been working with this type of timing relay for decades, and is also
including it in its new series.
Highlights฀from฀TELE
more info on
Page 87
more info on
Page 63 & 135
UL certification
Extensions to the product range for North America and Canada
Speciically, the ENYA installation series is being extended to
provide cULus certiication. Together with the industrial series
GAMMA and the compact industrial series DELTA it now constitutes
a full-range package for the export economy.
NEW
Neuestes Produkt: blabla
more info in our
new folder
more info on
Pages 113, 125 & 131
more info on
Page 99
more info on
Page 21
(Load) current
to 4 - 20 milliamps
Wide-range voltage
monitoring
The input stage can measure AC currents up to 15 A over three
switchable ranges. The conversion range can be optimally
adjusted to the 4-20mA output by means of a zero/span function.
Input, output and supply are separated three ways. The converter’s
versatility makes it an optimal adjunct to process automation
applications.
The product portfolio of the industrial series GAMMA has been
extended to include the G2PU690VS20, which offers voltage
monitoring over a remarkably wide range, namely 208 V to 690 V.
This unit is also able to draw its power from the voltage being
measured (supply voltage = measured voltage). This enables it
to cover a wide range of applications for both conventional power
grids at 230/400 V or 240/415 V and special industrial power
supplies up to 400/690 V.
w w w. tel e-o n l i n e. co m
NEW
NEW
Page 7
SENSING฀&฀
MONITORING
RELAYS
TELE offers the widest range of products with the following
performance features:
•
Measurement of one or more quantities such as voltage, current,
temperature and illing levels
•
Internal or external power supply (e.g. 24 V DC)
•
Monitor the voltage of ordinary mains grids at 230/400 V or
240/415 V as well as special industrial power supplies at
400/690 V
•
Various forms of housing for control engineering, industrial
systems and machine building as well as building installations;
variants available for DIN rails, front installation or an 11-pole
plug-in base
The robust design with generous terminal space throughout ensures
very good usability and installability.
OVERVIEW
Page
Monitoring Relays
Introduction
10
Selection matrix
Quick, explicit and time-saving to the right product.
12
Function overview
Explanations of important terms
16
Industrial Series: GAMMA
- Voltage 3-phase
- Voltage 1-phase
- Current 1-phase
- Current 3-phase
- Temperature
- Level
17
27
29
33
39
41
Industrial Series compact:
DELTA
Plugable Series: KAPPA
Installation Series: ENYA
- Voltage 3-phase
- Voltage 1-phase
- Current 1-phase
- Temperature
- Level
49
53
55
57
59
- Voltage 3-phase
- Voltage 1-phase
- Current 1-phase
61
61
61
- Voltage 3-phase
- Voltage 1-phase
- Current 1-phase
- Temperature
- Level
63
63
77
79
81
w w w. tel e-o n l i n e. co m
Page 9
WELCOME฀TO฀THE฀
WORLD฀OF฀THE฀
WATCHDOGS
coolZoom
The components mounted in a switching
cabinet lead in total to a substantial heat
development that has a negative impact
on the lifecycle of the entire control unit.
Through the use of state-of-the-art switching power supply technology, TELE reduces the energy consumption and thus
also the heat development. The typical
power consumption of the new products
thus lies below the 1W mark – simply
‘cool’. The lower operating temperature
irstly has a positive effect on the lifecycle and reliability of the components and
secondly results in substantial savings potential in the switching cabinet air climate
control system and ventilation. Another
beneit is demonstrated in the use of products in battery-buffered systems. Due to
the lower power consumption, the battery
Page 10
The monitoring relays with the WatchDog
label can display electrical values such
as current, voltage, power factor, power
performance, conductivity, resistance,
temperature etc., meaning these can
be monitored based on a limit value
and deviations displayed on a message
contact.
The housing is already a sign that
the system has a robust design. The
overvoltage category is consistently
indicated with 3 so that industrial network
environments do not present a problem.
With the disruptive inluences burst and
surge, the normative requirements are
more than fulilled. The operating safety of
can be designed in a smaller size with extended follow-up time.
With their extreme adaptability (zoom) to
any voltage supply
in the range of 24 to 240VAC/DC, generous tolerance ranges (20.4 to 264VAC or
19.2 to 300VDC) and their usage options
in the frequency range of 16 2/3 to 400Hz,
the devices from TELE are suitable for any
conceivable application.
the devices is thus ensured even with high
disruption potential.
One difference that makes a difference.
The temperature range in which the
devices can be operated is between
–25°C and +55°C.
The spacious operating front permits the
accommodation of many setting options
and display elements. A clear display
with a separate LED for each operating
mode is thus possible. There is only one
rule here, and this has been valid with
TELE for years: lashing LED means
‘time running’, continuously illuminated
LED means ‘time expired’. The operating
elements have a lush arrangement in the
front, whereby up to 5 setting elements
are possible in a 22.5 mm construction
width. This permits maximum functionality
on minimum space. As supply variants for
the auxiliary voltage, CoolZoom with 24240VAC/DC or the power modules with
nominal voltages of up to 400V(TR2) or
500V(TR3) are available.
The Watchdogs are now also being used
in the installation construction form thanks
to the ENYA series. With up to 5 setting
elements, an excellent operating comfort
can be reached in this construction form
too that is supplemented by up to four
display elements.
These can also serve as a diagnosis
PowerModules
In a simple and cost-effective manner, you
adapt the WatchDog monitoring relays and
load sentinels and the timing relays of the
GAMMA series to the respective supply
voltage. The plug-in power modules TR2
and TR3 are available for this and they
only have to be inserted into the lateral
supply slot of the devices.
The power modules TR2, with selectable
nominal voltages of 12 to 440VAC,
are envisaged for designs in 22.5mm
construction width, while
the power
modules TR3 with nominal voltages of up
to 500 V are suitable for types with a 45mm wide housing. The supply voltage can
therefore also be taken up by the outer
conductor voltage if a neutral cable is not
necessary in the application. The power
modules work particularly ‘quietly’ in the
display in ongoing operation, in order
to e.g. recognise in which phase the
breakdown has occurred. ENYA devices
can it in every energy distribution
cabinet and are thus ideally suited for
use in building automation and control
systems. They can be used to protect
against an unwanted operating status,
the detection of consumption points that
are switched on or for classical control
tasks. The application areas range from
the monitoring of a four-wire network via
one-phase monitoring applications to DC
monitoring of battery-buffered systems. A
diversity of current and voltage monitoring
relays in one- and three-phase design are
available. The supply with these devices
is integrated into the measuring circuit to
save clamp connections.
network, which means they are entirely
suited for class B applications according
to EN 55011 (living area). Another
advantage: In the event of maintenance,
the plug-in power module can be quickly
and conveniently replaced.
You simply order the right plug-in power
modules for your application separately.
Page 11
Page 12
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
SERIES
Design
n
n
n
n
n
GAMMA
Industry
n
n
n
n
n
3-phasig
n
n
n
n
n
Spannung
Under (UNDER)
n
n
n
n
Functions
Window (WIN)
n
n
n
Over (OVER)
Phase sequence (SEQ)
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Phase sequence (SEQ)
n
n
n
n
Asymmetry (ASYM)
Phase failure
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
GAMMA
Industry
Strom
1-phasig
n
n
n
n
n
n
n
3-phasig
n
Temperatur
n
n
n
n
n
n
n
n
Füllstand
n
SENSING฀&฀
MONITORING
RELAYS
Over (OVER)
Functions
Window (WIN)
Under (UNDER)
Tripping delay (DELAY)
Reverse Window
n
Fault latch (LATCH)
n
On delay (ON DELAY)
Adjustable thresholds
n
n
Testfunction (TEST/ RESET)
n
Short circuit monitoring
Zero-voltage latch
Output
2 CO contacts
1 CO contact
1 NO contact
cULus - Certiicates
Measured range
Supply voltage
n
n
n
n
n
n
n
(conductiv probe)
n
0,25 - 100k
n
n
230V AC
n
n
47
G2LM20 230V AC
n
(conductiv probe)
n
0,25 - 100k
n
n
110V AC
n
n
47
G2LM20 110V AC
n
(conductiv probe)
n
0,25 - 100k
n
24V AC
n
n
47
G2LM20 24V AC
n
PTC (motortemperature)
n
∑R <1,5k
n
230V AC
n
n
45
G2TF01 230V AC
n
PTC (motortemperature)
n
∑R <1,5k
n
n
12 - 440V AC, 24V DC 1)
n
n
45
G2TF01
n
PTC (motortemperature)
n
∑R <1,5k
n
n
110V AC
n
n
45
G2TF02 110V AC
n
PTC (motortemperature)
n
∑R <1,5k
n
n
230V AC
n
n
45
G2TF02 230V AC
n
PTC (motortemperature)
n
∑R <1,5k
n
n
12 - 440V AC, 24V DC 1)
n
n
43
G2TF02
n
PTC (motortemperature)
n
∑R <1,5k
n
n
24 - 240V AC/DC; CoolZoom 2)
n
n
43
G2TF02 24-240V
n
PTC (motortemperature)
n
∑R <1,5k
n
n
12 - 440V AC, 24V DC 1)
n
n
43
G2TFKN02
n
PTC (motortemperature)
n
∑R <1,5k
n
n
24 - 240V AC/DC; CoolZoom 2)
n
n
43
G2TFKN02 24-240V
n
PT100 2-/ 3-wire connection -50°C - +200°C
n
n
24 - 240V AC/DC; CoolZoom 2)
n
n
41
G2TMPT100L20 24-240V
n
3~ 5A AC (48 - 63Hz)
n
n
12 - 440V AC, 24V DC 1)
n
n
39
G2JM5AL20
n
3~ 5A AC (48 - 63Hz)
n
24 - 240V AC/DC; CoolZoom 2)
n
n
39
G2JM5AL20 24-240V
n
20mA; 1A; 5A AC/DC (48 - 63Hz)
n
12 - 440V AC, 24V DC 1)
n
n
37
G2IU5A10
n
100mA; 1A; 10A AC/DC (48 - 63Hz)
n
12 - 440V AC, 24V DC 1)
n
n
37
G2IU10A10
n
20mA; 1A; 5A AC/DC (48 - 63Hz)
n
12 - 440V AC, 24V DC 1)
n
n
37
G2IO5A10
n
100mA; 1A; 10A AC/DC (48 - 63Hz)
n
12 - 440V AC, 24V DC 1)
n
n
37
G2IO10A10
n
800mA;1,5A; 2A AC/DC (16,6 - 400Hz)
n
24 - 240V AC/DC; CoolZoom 2)
n
n
35
G2IM2AL20 24-240V
n
20mA; 1A; 5A AC/DC (16,6 - 400Hz)
n
n
12 - 440V AC, 24V DC 1)
n
n
35
G2IM5AL10
n
20mA; 1A; 5A AC/DC (16,6 - 400Hz)
n
n
12 - 440V AC, 24V DC 1)
n
n
35
G2IM5AL20
Start-up suppression (START)
20mA; 1A; 5A AC/DC (16,6 - 400Hz)
Adjustable hysteresis
24 - 240V AC/DC; CoolZoom 2)
n
n
33
G2IM5AL20 24-240V
n
100mA; 1A; 10A AC/DC (16,6 - 400Hz)
n
n
12 - 440V AC, 24V DC 1)
n
n
n
33
G2IM10AL10
n
n
33
100mA; 1A; 10A AC/DC (16,6 - 400Hz)
n
100mA; 1A; 10A AC/DC (16,6 - 400Hz)
12 - 440V AC, 24V DC 1)
n
24 - 240V AC/DC; CoolZoom
G2IM10AL20
n
33
G2IM10AL20 24-240V
2)
1-phasig
n
12 - 440V AC, 24V DC 1)
Type
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
31
G2UW300V10
n
31
G2UM10VL20 24-240V AC/DC 24 - 240V AC/DC; CoolZoom 2)
Technical Data Pages
n
n
n
n
29
n
n
n
2)
Reverse Window
Phase failure
n
n
n
n
n
n
n
n
Asymmetry (ASYM)
n
n
n
n
n
n
n
n
n
n
n
n
n
30V; 60V; 300V AC/DC (48 - 63Hz)
n
n
60mV; 150mV; 10V AC/DC (16,6 - 400Hz)
n
30V; 60V; 300V AC/DC (16,6 - 400Hz)
n
n
12 - 440V AC, 24V DC
n
n
31
G2UM300VL10
n
30V; 60V; 300V AC/DC (16,6 - 400Hz)
1)
n
n
12 - 440V AC, 24V DC
n
n
G2UM300VL20
Fault latch (LATCH)
30V; 60V; 300V AC/DC (16,6 - 400Hz)
1)
Adjustable thresholds
24 - 240V AC/DC; CoolZoom 2)
n
n
29
G2UM300VL20 24-240V
n
150V; 300V; 500V AC/DC (16,6 - 400Hz)
n
29
230V AC
n
n
24 - 240V AC/DC; CoolZoom
G2UM500VL10 230V
n
n
27
G2FW400VL20 24-240V
n
3(N)~ 66/115V AC (48 - 63Hz)
n
n
3(N)~ 99 - 132V AC
n
n
n
25
G2PF115VS02
n
n
25
3(N)~ 132/230V AC (48 - 63Hz)
Adjustable hysteresis
3(N)~ 230/400V AC (48 - 63Hz)
3(N)~ 198 - 264V AC
n
n
3(N)~ 342 - 457V AC
G2PF230VS02
n
n
25
G2PF400VS02
n
3N~ 230/400V AC (16,6 - 400Hz)
n
12 - 440V AC, 24V DC
Tripping delay (DELAY)
n
23
G2YM400VL20
Start-up suppression time (START)
n
21
3(N)~ 230/400V AC (48 - 63Hz)
1)
n
3~ 208 - 690V AC (48 bis 63Hz)
230V AC
n
3~ 177 - 794V AC
G2PU400VSY10 230V AC
n
n
21
G2PU690VS20
n
3~ 230/400V AC (48 - 63Hz)
n
12 - 440V AC, 24V DC
n
n
19
G2PW400V10
n
n
19
3(N)~ 66/115V AC (48 - 63Hz)
1)
n
3(N)~ 66/115V AC (48 - 63Hz)
12 - 440V AC, 24V DC 1)
On delay (ON DELAY)
24 - 240V AC/DC; CoolZoom
G2PM115VSY10
n
n
19
G2PM115VSY20 24-240V
n
3(N)~ 132/230V AC (48 - 63Hz)
2)
n
12 - 440V AC, 24V DC
n
n
G2PM230VSY10
n
3(N)~ 132/230V AC (48 - 63Hz)
1)
n
24 - 240V AC/DC; CoolZoom 2)
n
n
n
19
G2PM230VSY20 24-240V
n
n
17
3(N)~ 230/400V AC (48 - 63Hz)
Testfunction (TEST/ RESET)
3(N)~ 230/400V AC (48 - 63Hz)
12 - 440V AC, 24V DC 1)
n
n
12 - 440V AC, 24V DC
G2PM400VSY10
n
n
17
G2PM400VSY20
Short circuit monitoring
3(N)~ 230/400V AC (48 - 63Hz)
1)
n
n
24 - 240V AC/DC; CoolZoom 2)
n
n
17
G2PM400VSY20 24-240V
Output
n
3(N)~ 500V AC (48 - 63Hz)
Zero-voltage latch
n
17
12 - 440V AC, 24V DC 1)
n
3(N)~ 400/690V AC (48 - 63Hz)
G4PM500VSYL20
19
17
12 - 440V AC, 24V DC 1)
1 CO contact
1 NO contact
2 CO contacts
Measured range
cULus - Certiicates
Supply voltage
Type
Technical Data Pages
G4PM690VSYL20
Page 13
Page 14
n
24V AC
PTC (motortemperature) ∑R < 1,5k
n
57
TT2X 230V AC
230V AC
PTC (motortemperature) ∑R <1,5k
n
59
TLH4X 24V AC
24V AC
0,25 - 5k / 5 - 100k
(conductiv probe)
59
TLH4X 230V AC
230V AC
0,25 - 5k / 5 - 100k
(conductiv probe)
59
TLC4X 230V AC
230V AC
5 - 100k
61
K3YM400VSY20
3(N)~ 230/400V AC
3(N)~ 230/400V AC (48 - 63Hz)
n
n
n
n
n
61
K3PF400VSY02
3(N)~ 230/400V AC
3(N)~ 230/400V AC (48 - 63Hz)
n
61
K3UM230VAC02
230V AC
230V AC (48 - 63Hz)
n
n
n
n
n
61
K3UM24VDC02
24V DC
24V DC
n
n
n
n
n
61
K3IM5AACL20 230V
230V AC
5A AC (48 - 63Hz)
63
E3YF400V02 0.85
= measured range
3N~ 230/400V AC (48 - 63Hz)
n
n
63
E3YF400VE20 0.85
= measured range
3N~ 230/400V AC (48 - 63Hz)
n
n
63
E3YF400VT02 0.85
= measured range
3N~ 230/400V AC (48 - 63Hz)
n
n
63
E3YF400VT02 HTV 0.85
= measured range
3N~ 230/400V AC (48 - 63Hz)
65
E1YF400V01 0.85
= measured range
3N~ 230/400V AC (48 - 63Hz)
65
E1YF400VT01 0.85
= measured range
3N~ 230/400V AC (48 - 63Hz)
65
E1YF400V01 0.70
= measured range
3N~ 230/400V AC (48 - 63Hz)
67
E3YM230VS20
= measured range
3(N)~ 132/230V AC (48 - 63Hz)
67
E1YM400VS10
= measured range
3(N)~ 230/400V AC (48 - 63Hz)
67
E1YM480Y/277VS10
= measured range
3~ 277/480V AC (48 - 63Hz)
n
69
E3YU400V02
= measured range
3(N)~ 230/400V AC (48 - 63Hz)
n
69
E1YU400V01
= measured range
3(N)~ 230/400V AC (48 - 63Hz)
71
E3YF400VFAL02
= measured range
3(N)~ 230/400V AC (48 - 63Hz)
73
E3PF400VSY02
= measured range
3(N)~ 230/400V AC (48 - 63Hz)
73
E1PF400VSY01
= measured range
3(N)~ 230/400V AC (48 - 63Hz)
73
E1PF480Y/277VSY10
= measured range
3~ 277/480V AC (48 - 63Hz)
n
75
E1UM230V01
= measured range
24V AC/DC; 230V AC (48 - 63Hz)
n
75
E1UU230V01
= measured range
24V AC/DC; 230V AC (48 - 63Hz)
n
77
E3IM10AL20
230V AC
100mA; 1A; 10A AC/DC (16,6 - 400Hz)
77
E1IM10AACL10
230V AC
10A AC (48 - 63Hz)
n
n
77
E1IU5AAC01
230V AC
5A AC (48 - 63Hz)
n
n
77
E1IU500mAAC01
230V AC
500mA AC (48 - 63Hz)
n
n
79
E3TF01
230V AC
PTC (motortemperature) ∑R <1,5k
n
n
81
E3LM10
230V AC
0,25 - 100k
Industry฀compact
57
TT2X 24V AC
n
n
n
1-phase
Current
n
n
n
n
n
n
n
n
n
n
n
n
n
53
1-phase
2 x PTC (motortemperature) ∑R <1,5k
TREND
3-phase
12 - 440V AC, 24V DC 1)
Voltage
57
TDT4X
n
15A AC (48 - 63Hz)
n
230V AC
n
n
n
Temperature
n
n
n
n
n
n
n
n
n
n
n
n
n
Level
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
KAPPA
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Current
1~
Industry฀plug-in
1-phase
Voltage
3-phase
n
n
n
ENYA
n
n
Installation
n
n
n
n
n3)
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
3-phase
n
n
Voltage
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
1-phase
n
n
n
n
n
n
n
n
n
n
1-phase
n
n
Level
n
Current
n
n
n
Temp.
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
SENSING฀&฀
MONITORING
RELAYS
Over (OVER)
Functions
Window (WIN)
Under (UNDER)
Phase sequence (SEQ)
Reverse Window
Asymmetry (ASYM)
Phase failure
Fault latch (LATCH)
Adjustable thresholds
Start-up suppression (START)
On delay (ON DELAY)
Tripping delay (DELAY)
Adjustable hysteresis
n
Short circuit monitoring
Testfunction (TEST/ RESET)
Zero-voltage latch
Output
2 CO contacts
1 CO contact
1 NO contact
cULus - Certiicates
Measured range
Supply voltage
Type
Technical Data Pages
n
(conductiv probe)
SERIES
Design
n
n
55
TIF30-300mAAC4X
n
100mA; 1A; 10A AC/DC (48 - 63Hz)
n
12 - 440V AC, 24V DC 1)
n
55
TIH4X
n
100mA; 1A; 10A AC/DC (48 - 63Hz)
n
12 - 440V AC, 24V DC
n
55
TIW4X
n
30V; 60V; 300V; 600V AC/DC (48 - 63Hz)
1)
n
12 - 440V AC, 24V DC
n
TUH4X
n
24V; 115V; 230;V 440V AC/DC (48 - 63Hz)
1)
53
12 - 440V AC, 24V DC
1)
(conductiv probe)
Functions
n
n
n
n
n
Over (OVER)
n
n
n
n
n
n
Window (WIN)
n
n
n
Under (UNDER)
Reverse Window
n
n
n
n
n
n
n
n
n
Phase sequence (SEQ)
n
n
n
n
n
n
n
Phase failure
n
n
n
3~ 230/400V AC (48 - 63Hz)
Asymmetry (ASYM)
Fault latch (LATCH)
Adjustable thresholds
Adjustable hysteresis
Start-up suppression (START)
n
TUW4X
n
3~ 400V AC
n
51
TPF400VS4X
On delay (ON DELAY)
3~ 132/230V AC (48 - 63Hz)
Tripping delay (DELAY)
3~ 230V AC
Testfunction (TEST/ RESET)
51
TPF230VS4X
Short circuit monitoring
3(N)~ 230/400V AC (48 - 63Hz)
Output
12 - 440V AC, 24V DC 1)
Zero-voltage latch
49
TPW400VN4X
n
3(N)~ 66/115V AC (48 - 63Hz)
n
12 - 440V AC, 24V DC 1)
n
49
TPW115VSN4X
n
3(N)~ 133/230V AC (48 - 63Hz)
n
12 - 440V AC, 24V DC 1)
1 CO contact
49
TPW230VSN4X
2 CO contacts
3(N)~ 230/400V AC (48 - 63Hz)
1 NO contact
Measured range
49
12 - 440V AC, 24V DC 1)
cULus - Certiicates
Supply voltage
Type
Technical Data Pages
1) Power module TR (AC) series and Switching power supply SNT (DC) series ; 2) Lower power loss <1W; 3) Gold-plated contacts ensure extremely low
contact resistance
TPW400VSN4X
Page 15
FUNCTIONSOVERVIEW
OVER
WIN
UNDER
The output relay remains switched
on until the monitored value exceeds
the maximum value. As soon as
the monitored value falls below the
minimum value, the output relay
switches to the on position again.
The output relay remains switched
on until the monitored value lies
within the deined window. As soon
as the monitored value enters the
deined window again, the output relay
switches to the on position again.
The output relay remains switched
on until the monitored value falls
below the minimum value. As soon
as the monitored value exceeds the
maximum value, the output relay
switches to the on position again.
Max
Max
Max
Min
Min
Min
DELAY
ON-DELAY
LATCH (Fault latch)
If the monitored value leaves the
selected range, the output relay only
switches to the off position following
expiry of the trip delay.
The output relay switches on if the
monitored value is within the selected
range during the deined time period.
If the device detects a fault, the output
relay only switches on again when the
fault latch has been reset. The fault
latch can be reset by means of an
internal or external reset button or by
interrupting the supply voltage.
U
Reset
Max
Max
Min
Min
Max
Min
Delay
ON-Delay
ON-Delay
START-UP
I=0 Detection
The output relay switches on when the
supply voltage is applied. Changes to
measured variables have no impact on
the setting of the output relay during
start-up suppression.
Deactivated consumers are detected with
I=0 detection. As soon as the current low
is supplied again, the measurement cycle
commences again with the expiry of the
deined start-up suppression.
Max
Min
Start
Page 16
Delay
Sensing & Monitoring Relays Series GAMMA
Voltage monitoring in 3-phase mains
<
Multifunction
<
Monitoring of phase sequence and phase failure
<
Asymmetry detection switchable
<
Connection of neutral wire optional
<
Detection of loss of neutral wire
<
Fault latch (G4PM)
<
Supply voltage selectable via PowerModules or by zoom voltage 24 to 240V AC/DC
<
1 CO contact; 2 CO contacts
<
Width 22,5mm or 45mm; Industrial design
G4PM690VSYL20
G4PM500VSYL20
G2PM400VSY20
24-240V
G2PM400VSY20
G2PM400VSY10
Art.No. (PQ1)
2394500
2394501
2390505
2390504
2390500
Art.No. (PQ10)
-
-
-
-
-
900866200296
900866200297
900866200284
900866200281
900866200276
Measured variable
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
Measured range
UN = 690/400V
terminals (N)-L1-L2-L3
UN = 500V
terminals (N)-L1-L2-L3
UN = 400/230V
terminals (N)-L1-L2-L3
UN = 400/230V
terminals (N)-L1-L2-L3
UN = 400/230V
terminals (N)-L1-L2-L3
ASYM • max • min •
Delay • Function
ASYM • max • min •
Delay • Function
ASYM • max • min •
Delay • Function
ASYM • max • min •
Delay • Function
ASYM • max • min •
Delay • Function
ASYM • max • min • SEQ
•R
ASYM • max • min • SEQ
•R
ASYM • max • min • SEQ
•R
ASYM • max • min • SEQ
•R
ASYM • max • min • SEQ
•R
UNDER
UNDER+SEQ
WIN
WIN+SEQ
UNDER+LATCH
UNDER+SEQ+LATCH
WIN+LATCH
WIN+SEQ+LATCH
UNDER
UNDER+SEQ
WIN
WIN+SEQ
UNDER+LATCH
UNDER+SEQ+LATCH
WIN+LATCH
WIN+SEQ+LATCH
UNDER
UNDER+SEQ
WIN
WIN+SEQ
UNDER
UNDER+SEQ
WIN
WIN+SEQ
UNDER
UNDER+SEQ
WIN
WIN+SEQ
5% to 25% • Off
5% to 25% • Off
5% to 25% • Off
5% to 25% • Off
5% to 25% • Off
types
EAN13-Code
Controls
Indicators (LEDs)
Functions
Asymmetry
Switching threshold max.
-20% to 30% from UN
-20% to 30% from UN
-20% to 30% from UN
-20% to 30% from UN
-20% to 30% from UN
Switching threshold min.
-30% to 20% from UN
-30% to 20% from UN
-30% to 20% from UN
-30% to 20% from UN
-30% to 20% from UN
0,1s to 10s
0,1s to 10s
0,1s to 10s
0,1s to 10s
0,1s to 10s
Tripping delay
Start-up suppression time
-
-
-
-
-
selectable
selectable
-
-
-
Supply
PowerModule TR3
terminals A1-A2
PowerModule TR3
terminals A1-A2
24 to 240V AC/DC
terminals A1-A2
PowerModule TR2
terminals A1-A2
PowerModule TR2
terminals A1-A2
Output
2 CO contacts; 250V,
5A AC
2 CO contacts; 250V,
5A AC
2 CO contacts; 250V,
5A AC
2 CO contacts; 250V,
5A AC
1 CO contact; 250V,
5A AC
Fault latch
Width
Certiicates
Mechanical
design
45mm
45mm
22,5mm
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
PowerModulees TR2 (12 - 400V AC) and TR3 (12 - 500V AC) • sealable intervention protection shield FA-G2 • DC power supply SNT2 24VDC
w w w. tel e-o n l i n e. co m
Page 17
UNDER
UNDER+SEQ
WIN
WIN+SEQ
UNDER+Latch
UNDER+SEQ+Latch
WIN+Latch
WIN+SEQ+Latch
G4PM690VSYL20 with PowerModule 24V AC
N
G4PM690VSYL20 with PowerModule 400V
Sensing & Monitoring Relays Series GAMMA
Functions
Undervoltage monitoring
Undervoltage monitoring and monitoring of phase sequence
Monitoring the window between Min and Max
Monitoring the window between Min and Max and monitoring of phase sequence
Undervoltage monitoring with fault latch
Undervoltage monitoring and monitoring of phase sequence with fault latch
WIN with fault latch
Monitoring the window between Min and Max and monitoring of phase sequence with fault latch
G4PM500VSYL20 with PowerModule 500V AC
Connections
Voltage monitoring in 3-phase mains
<
Multifunction (G2PM); Windowfunction (G2PW)
<
Monitoring of phase sequence and phase failure (G2PM)
<
Asymmetry detection switchable (G2PM)
<
Connection of neutral wire optional (G2PM)
<
Detection of loss of neutral wire (G2PM)
<
Supply voltage selectable via PowerModules or by zoom voltage 24-240V
<
1 CO contact; 2 CO contacts
<
Width 22,5mm
<
Industrial design
G2PM230VSY20
24-240V
G2PM230VSY10
G2PM115VSY20
24-240V
G2PM115VSY10
G2PW400V10
Art.No. (PQ1)
2390512
2390503
2390506
2390502
2390501
Art.No. (PQ10)
-
-
-
-
-
900866200287
900866200280
900866200516
900866200279
900866200277
Measured variable
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
3~
AC Sinus (48 to 63Hz)
Measured range
UN = 230/132V
terminals (N)-L1-L2-L3
UN = 230/132V
terminals (N)-L1-L2-L3
UN = 115/66V
terminals (N)-L1-L2-L3
UN = 115/66V
terminals (N)-L1-L2-L3
UN = 400/230V
terminals L1-L2-L3
ASYM • max • min •
Delay • Function
ASYM • max • min •
Delay • Function
ASYM • max • min •
Delay • Function
ASYM • max • min •
Delay • Function
max • min • Delay
ASYM • max • min • SEQ
•R
ASYM • max • min • SEQ
•R
ASYM • max • min • SEQ
•R
ASYM • max • min • SEQ
•R
U • max • min • R
UNDER
UNDER+SEQ
WIN
WIN+SEQ
UNDER
UNDER+SEQ
WIN
WIN+SEQ
UNDER
UNDER+SEQ
WIN
WIN+SEQ
UNDER
UNDER+SEQ
WIN
WIN+SEQ
WIN
5% to 25% • Off
5% to 25% • Off
5% to 25%
5% to 25% • Off
-
types
N
24V AC
0V
F1-3
max. 20A
Reset
F1-3
max. 20A
Reset
15
25
16 18
26 28
15
25
16 18
26 28
F1-3
max. 20A
Reset
15
25
16 18
26 28
EAN13-Code
G2PM400VSY20 24V to 240V AC/DC
Connections
G2PM400VSY20 with PowerModule 230V AC
Controls
24VAC/DC
F1-3
max. 20A
F1-3
max. 20A
Indicators (LEDs)
Functions
15
25
16 18
26 28
15
25
16 18
26 28
Asymmetry
Switching threshold max.
-20% to 30% from UN
-20% to 30% from UN
-20% to 30% from UN
-20% to 30% from UN
-20% to 30% from UN
Switching threshold min.
-30% to 20% from UN
-30% to 20% from UN
-30% to 20% from UN
-30% to 20% from UN
-30% to 20% from UN
0,1s to 10s
0,1s to 10s
0,1s to 10s
0,1s to 10s
0,2s to 10s
Tripping delay
Width 22,5mm
Start-up suppression time
-
-
-
-
-
Fault latch
-
-
-
-
-
Supply
24 to 240V AC/DC
terminals A1-A2
PowerModule TR2 or
SNT2
terminals A1-A2
24 to 240V AC/DC
terminals A1-A2
PowerModule TR2 or
SNT2
terminals A1-A2
PowerModule TR2 or
SNT2
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
1 CO contact
250V, 5A AC
2 CO contacts
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Dimensions
Width 45mm
Width
Certiicates
Powermodul
90mm
Mechanical
design
Page 18
45mm
22,5mm
22,5mm
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
5mm
103mm
22,5mm
CE • cULus • GOST
Accessories
PowerModulee TR2 (12 - 440V AC) • DC power supply SNT2 24V DC • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 19
UNDER
UNDER+SEQ
WIN
WIN+SEQ
G2PM with PowerModule 24V AC
G2PM with PowerModule 230VAC
Sensing & Monitoring Relays Series GAMMA
Functions
Undervoltage monitoring
Undervoltage monitoring and monitoring of phase sequence
Monitoring the window between Min and Max
Monitoring the window between Min and Max and monitoring of phase sequence
G2PM with PowerModule 400VAC
Connections
Voltage monitoring in 3-phase mains
<
Multifunction (G2PM); Windowfunction
<
Monitoring of phase sequence and phase failure
<
Asymmetry detection switchable
<
Connection of neutral wire optional
<
Detection of loss of neutral wire
<
Supply voltage selectable via PowerModules or by zoom voltage 24-240V
<
1 CO contact; 2 CO contacts
<
Width 22,5mm
<
Industrial design
G2PU690VS20
G2PU400VSY10
230V AC
Art.No. (PQ1)
2390507
2390511B
Art.No. (PQ10)
-
-
9008662006454
9008662006652
3~
AC Sinus (48 bis 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
208V to 690V
terminals L1-L2-L3
UN = 400/230V
terminals (N)-L1-L2-L3
types
F1-3
max. 20A
F1-3
max. 20A
15
16 18
F1-3
max. 20A
15
15
25
16 18
16 18
26 28
EAN13-Code
Measured variable
Width 22,5mm
Dimensions
Measured range
min • Delay
ASYM • max • min
U • min • SEQ • R
ASYM • max • min • SEQ • R
Functions
UNDER+SEQ
UNDER+SEQ
Asymmetry
ixeded, 25%
5% to 25%
Switching threshold max.
-
-20% to +30% from UN
Switching threshold min.
180V to 690V
-30% to +20% from UN
0,1s to 10s
-
-
-
Controls
Indicators (LEDs)
Tripping delay
Start-up suppression time
Fault latch
-
-
Supply
= measuring voltage
3~ 177V to 794V
Terminals L1-L2-L3
230V AC
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
1 CO contact
250V, 5A AC
Width
Certiicates
Mechanical
design
22,5mm
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 20
22,5mm
CE • GOST
Sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 21
UNDER+SEQ
Undervoltage monitoring and monitoring of phase sequence
G2PU400VSY10, supply voltage 230V AC
Sensing & Monitoring Relays Series GAMMA
Functions
Voltage monitoring in 3-phase mains
<
Multifunction
<
Monitors phase to neutral voltages
<
Connection of neutral wire necessary
<
Fault latch
<
Supply voltage selectable via PowerModules or DC power supply
<
2 CO contacts
<
Width 22,5mm
<
Industrial design
Connections
G2PU690VS20
types
G2YM400VL20
F1-3
max. 20A
L3
L1
15
16 18
L2
15
25
16 18
26 28
25 26 28
15 16 18
Art.No. (PQ1)
Art.No. (PQ10)
EAN13-Code
Measured variable
Width 22,5mm
Dimensions
Measured range
Controls
900866200285
3N~
AC Sinus (16 to 400Hz)
UN = 400/230V
terminals N-L1-L2-L3
max • min • Delay • Function
Indicators (LEDs)
U • max • min • R
Functions
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
Asymmetry
-
Switching threshold max.
-20% to 30% from UN
Switching threshold min.
-30% to 20% from UN
Tripping delay
Start-up suppression time
Fault latch
0,1s to 10s
selectable
Supply
PowerModule TR2 or SNT2
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
Width
Certiicates
Mechanical
design
22,5mm
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 22
2390508
PowerModulee TR2 (12 to 440V AC) • DC power supply SNT2 24V DC • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 23
OVER
OVER+Latch
UNDER
UNDER+Latch
WIN
WIN+Latch
G2YM400VL20 with PowerModule 24V AC without fault latch
Sensing & Monitoring Relays Series GAMMA
Functions
Overvoltage monitoring
Overvoltage monitoring with fault latch
Undervoltage monitoring
Undervoltage monitoring with fault latch
Monitoring the window between Min and Max
Monitoring the window between Min and Max with fault latch
G2YM400VL20 with PowerModule 230V AC with fault latch
Voltage monitoring in 3-phase mains
<
Monitoring of phase sequence and phase failure
<
Detection of reverse voltage
<
Connection of neutral wire optional
<
Supply voltage = measuring voltage
<
2 CO contacts
<
Width 22,5mm
<
Industrial design
Connections
G2PF400VS02
G2PF230VS02
G2PF115VS02
Art.No. (PQ1)
2390000
2390001
2390002
Art.No. (PQ10)
2390000B
-
-
900866200229
900866200232
900866200234
Measured variable
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
Measured range
UN = 400/230V
terminals (N)-L1-L2-L3
UN = 230/132V
terminals (N)-L1-L2-L3
UN = 115/66V
terminals (N)-L1-L2-L3
types
24V~
0V
F1-3
max. 20A
Reset
F1-3
max. 20A
N
L1 L2 L3
N
L1 L2 L3
15
25
16 18
26 28
15
25
16 18
26 28
EAN13-Code
G2YM400VL20 with PowerModule 230V AC without fault latch
Connections
Controls
F1-3
max. 20A
25
16 18
26 28
-
-
U•R
U•R
Monitoring of phase sequence and phase
failure
Monitoring of phase sequence and phase
failure
Monitoring of phase sequence and phase
failure
ixed, typ. 30%
ixed, typ. 30%
ixed, typ. 30%
Switching threshold max.
-
-
-
Switching threshold min.
-
-
-
Tripping delay
ixed, max. 350ms
ixed, max. 350ms
ixed, max. 350ms
Start-up suppression time
ixed, max. 500ms
ixed, max. 500ms
ixed, max. 500ms
-
-
-
Supply
= measuring voltage
3(N)~ 342 to 457V
terminals (N)-L1-L2-L3
= measuring voltage
3(N)~ 198 to 264V
terminals (N)-L1-L2-L3
= measuring voltage
3(N)~ 99 to 132V
terminals (N)-L1-L2-L3
Output
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
Functions
Asymmetry
N
L1 L2 L3
15
U•R
Indicators (LEDs)
Fault latch
Width 22,5mm
Dimensions
Width
Certiicates
Mechanical
design
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 24
22,5mm
CE • cULus • GOST
-
w w w. tel e-o n l i n e. co m
Page 25
Monitoring of phase sequence, phase failure with detection of return voltage
G2PF...S02
Sensing & Monitoring Relays Series GAMMA
Functions
Frequency monitoring for 50/60Hz networks
<
Window function
<
Measured voltage 110V to 400V
<
Error memory
<
Voltage breakdown detection
<
Supply voltage 24 to 240V AC/DC
<
2 CO contacts
<
Width 22,5mm
<
Industrial design
Connections
types
Art.No. (PQ1)
Art.No. (PQ10)
EAN13-Code
Measured variable
Width 22,5mm
Dimensions
Measured range
Controls
Indicators (LEDs)
Functions
2390900
9008662006607
Frequency, 1-phae
terminals F-E
110V to 400V
terminals F-E
Start • max • min • Delay • Function
U/t • max • min • UFailure • R
WIN
Switching threshold max.
FN = 50Hz: 49, 49.5, 50, 50.5, 51, 52, 53,55, 57.5, 60Hz
FN = 60Hz: 59, 59.5, 60, 60.5, 61, 62, 63, 65, 67.5, 70Hz
Switching threshold min.
FN = 50Hz: 40, 42.5, 45, 47, 48, 49, 49.5, 50, 50.5, 51Hz
FN = 60Hz: 50, 52.5, 55, 57, 58, 59, 59.5, 60, 60.5, 61Hz
Tripping delay
Start-up suppression time
Fault latch
0,1s to 10s
0s to 10s
-
Supply
24 to 240V AC/DC
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
Width
22,5mm
Certiicates
Mechanical
design
CE
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 26
G2FW400VL20 24-240V
PowerModule TR2 (12 to 440V AC) • DC power supply SNT2 24V DC • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 27
G2FW400VL20 24-240V:
Frequency monitoring for 50/60Hz supply with adjustable thresholds, separately adjustable on delay and trip delay.
50Hz:
WIN:
WIN+Latch:
60Hz:
WIN:
WIN+Latch:
Window monitoring, monitoring of range..., FN=50Hz
Window monitoring with error memory, FN=50Hz
Window monitoring, monitoring of range..., FN=60Hz
Window monitoring with error memory, FN=60Hz
G2FW400VL20, measured voltage = 400V AC (phase-phase)
supply voltage 24-240V AC/DC
Sensing & Monitoring Relays Series GAMMA
Functions
Voltage monitoring in 1-phase mains
<
Multifunction
<
Frequency range 16,6 to 400Hz
<
Fault latch
<
Supply voltage selectable via PowerModules or by zoom voltage 24 to 240V AC/DC
<
1 CO contact; 2 CO contacts
<
Width 22,5mm
<
Industrial design
Connections
G2UM500VL10 230V
G2UM300VL20
24-240V AC
G2UM300VL20
Art.No. (PQ1)
2390306A
2390304
2390303
Art.No. (PQ10)
-
-
-
900866200262
900866200260
900866200259
Measured variable
Voltage AC/DC
AC Sinus (16,6 to 400Hz)
Voltage AC/DC
AC Sinus (16,6 to 400Hz)
Voltage AC/DC
AC Sinus (16,6 to 400Hz)
Measuring ranges
150V; terminals E-F1(+)
300V; terminals E-F2(+)
500V; terminals E-F3(+)
30V; terminals E-F1(+)
60V; terminals E-F2(+)
300V; terminals E-F3(+)
30V; terminals E-F1(+)
60V; terminals E-F2(+)
300V; terminals E-F3(+)
Start • max • min • Delay • Function
Start • max • min • Delay • Function
Start • max • min • Delay • Function
U/t • max • min • R
U/t • max • min • R
U/t • max • min • R
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
Switching threshold max.
10% to 100% from UN
10% to 100% from UN
10% to 100% from UN
Switching threshold min.
5% to 95% from UN
5% to 95% from UN
5% to 95% from UN
0,1s to 10s
0,1s to 10s
0,1s to 10s
types
Umax = 3x400V
24VAC/DC
E
F
15
25
16 18
26 28
EAN13-Code
Width 22,5mm
Dimensions
Controls
Indicators (LEDs)
Functions
Tripping delay
Start-up suppression time
0s to 10s
0s to 10s
0s to 10s
Fault latch
selectable
selectable
selectable
Supply
230V AC
terminals A1-A2
24 to 240V AC/DC
terminals A1-A2
PowerModule TR2 or
SNT2
terminals A1-A2
Output
1 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
Width
Certiicates
Mechanical
design
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 28
22,5mm
CE • cULus • GOST
PowerModule TR2 (12 to 440V AC) • DC power supply SNT2 24V DC • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 29
Overvoltage monitoring
UNDERvoltage monitoring
Monitoring the window between Min and Max
OVER+Latch
UNDER+Latch
WIN+Latch
Overvoltage monitoring with fault latch
UNDERvoltage monitoring with fault latch
Monitoring the window between Min and Max with fault latch
G2UM500VL10, measuring range: 300V
supply voltage: 230V AC
Sensing & Monitoring Relays Series GAMMA
Functions
OVER
UNDER
WIN
Voltage monitoring in 1-phase mains
G2UM300VL20, measuring range: 300V
supply voltage: 24-240V AC/DC
G2UM300VL20, measuring range: 30V
supply voltage: 24V AC
Umax= 300V AC/DC
Umax=300V AC/DC
Umax=30V AC/DC
L
N
24VAC/DC
0V
24V~
0V
max.
20A
<
Multifunction (G2UM); Windowfunction (G2UW)
<
Frequency range 16,6 to 400Hz (G2UM)
<
Fault latch (G2UM)
<
Supply voltage selectable via PowerModules or by zoom voltage 24 to 240V AC/DC
<
1 CO contact; 2 CO contacts
<
Width 22,5mm
<
Industrial design
Connections
G2UM300VL10
G2UM10VL20
24-240V AC/DC
G2UW300V10
Art.No. (PQ1)
2390300
2390307
2390301
Art.No. (PQ10)
-
-
-
900866200256
9008662006089
900866200257
Measured variable
Voltage AC/DC
AC Sinus (16 to 400Hz)
Voltage AC/DC
AC Sinus (16 to 400Hz)
Voltage AC/DC
AC Sinus (48 to 63Hz)
Measuring ranges
30V; terminals E-F1(+)
60V; terminals E-F2(+)
300V; terminals E-F3(+)
60mV; terminals E-F1(+)
150mV; terminals E-F2(+)
10V; terminals E-F3(+)
30V; terminals E-F1(+)
60V; terminals E-F2(+)
300V; terminals E-F3(+)
Start • max • min • Delay • Function
Start • max • min • Delay • Function
max • min • Delay
U/t • max • min • R
U/t • max • min • R
U • max • min • R
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
WIN
Switching threshold max.
10% to 100% from UN
10% to 100% from UN
10% to 100% from UN
Switching threshold min.
5% to 95% from UN
5% to 95% from UN
5% to 95% from UN
0,1s to 10s
0,1s to 10s
0,2s to 10s
-
types
max.
20A
max.
20A
Reset
Reset
Reset
15
16 18
15
25
16 18
26 28
15
25
16 18
26 28
EAN13-Code
Width 22,5mm
Dimensions
Controls
Indicators (LEDs)
Functions
Tripping delay
Start-up suppression time
0s to 10s
0s to 10s
wire link Y1-Y2
selectable
-
Supply
PowerModule TR2 or SNT2
terminals A1-A2
24 to 240V AC/DC
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
Output
1 CO contact
250V, 5A AC
2 CO contacts
250V, 5A AC
1 CO contact
250V, 5A AC
Fault latch
Width
Certiicates
Mechanical
design
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 30
22,5mm
CE • cULus • GOST
PowerModulee TR2 (12 to 440V AC) • DC power supply SNT2 24V DC • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 31
OVER
UNDER
WIN
G2UM
Fault latch via wire link Y1-Y2 selectable
OVER+Latch
Overvoltage monitoring with fault latch
UNDER+Latch
UNDERvoltage monitoring with fault latch
WIN+Latch
Monitoring the window between Min and Max with fault latch
G2UM300VL10, measuring range 60V AC/DC, G2UW300V10, measuring range 30V AC/DC, G2UM10VL20, measuring range: 60mV AC/DC,
supply voltage: 24V AC
supply voltage: 24V AC/DC
supply voltage: 230V AC
Umax=60V AC/DC
L1
N
max.
20A
Sensing & Monitoring Relays Series GAMMA
Functions
Overvoltage monitoring
UNDERvoltage monitoring
Monitoring the window between Min and Max
Umax=30V AC/DC
Umax=60mV AC/DC
24V~
0V
24V AC/DC
0V
max.
20A
Current monitoring in 1-phase mains
<
Multifunction
<
Frequency range 16,6 to 400Hz
<
Fault latch
<
Supply voltage selectable via PowerModules or by zoom voltage 24 to 240V AC/DC
<
1 CO contact; 2 CO contacts
<
Width 22,5mm
<
Industrial design
types
G2IM10AL20
24-240V
G2IM10AL20
G2IM10AL10
G2IM5AL20
24-240V
Art.No. (PQ1)
2390410
2390406
2390400
2390411
Art.No. (PQ10)
-
-
-
-
900866200273
900866200269
900866200263
900866200274
Measured variable
Current AC/DC
AC Sinus (16,6 to 400Hz)
Current AC/DC
AC Sinus (16,6 to 400Hz)
Current AC/DC
AC Sinus (16,6 to 400Hz)
Current AC/DC
AC Sinus (16,6 to 400Hz)
Measuring ranges
100mA AC/DC; terminals K-I1(+)
1A AC/DC; terminals K-I2(+)
10A AC/DC; terminals K-I3(+)
100mA AC/DC; terminals K-I1(+)
1A AC/DC; terminals K-I2(+)
10A AC/DC; terminals K-I3(+)
100mA AC/DC; terminals K-I1(+)
1A AC/DC; terminals K-I2(+)
10A AC/DC; terminals K-I3(+)
20mA AC/DC; terminals K-I1(+)
1A AC/DC; terminals K-I2(+)
5A AC/DC; terminals K-I3(+)
Start • max • min • Delay •
Function
Start • max • min • Delay •
Function
Start • max • min • Delay •
Function
Start • max • min • Delay •
Function
U/t • max • min • R
U/t • max • min • R
U/t • max • min • R
U/t • max • min • R
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
OVER
OVER+Latch
UNDER
UNDER + Latch
WIN
WIN+Latch
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
Switching threshold max.
10% to 100% from IN
10% to 100% from IN
10% to 100% from IN
10% to 100% from IN
Switching threshold min.
5% to 95% from IN
5% to 95% from IN
5% to 95% from IN
5% to 95% from IN
0,1s to 10s
0,1s to 10s
0,1s to 10s
0,1s to 10s
Connections
max.
20A
Reset
Reset
15
16 18
25
26 28
15
15
25
16 18
26 28
16 18
EAN13-Code
Width 22,5mm
Dimensions
Controls
Indicators (LEDs)
Functions
Tripping delay
Start-up suppression time
0s to 10s
0s to 10s
0s to 10s
0s to 10s
Fault latch
selectable
selectable
selectable
selectable
Supply
24 to 240V
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
24 to 240V
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
1 CO contact
250V, 5A AC
2 CO contacts
250V, 5A AC
Width
Certiicates
Mechanical
design
22,5mm
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 32
22,5mm
CE • cULus • GOST
PowerModulee TR2 (12 to 440V AC) • DC power supply SNT2 24V DC • Current Transformers Series DSW and WSW • sealable intervention
protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 33
Overcurrent monitoring
Undercurrent monitoring
Monitoring the window between Min and Max
OVER+Latch
UNDER+Latch
WIN+Latch
Overcurrent monitoring with fault latch
Undercurrent monitoring with fault latch
Monitoring the window between Min and Max with fault latch
Measured range 100mA AC/DC,
supply voltage: 24V AC/DC
Sensing & Monitoring Relays Series GAMMA
Functions
OVER
UNDER
WIN
Measured range 1A AC/DC with
Powermodule 230V AC
Measured range 5A AC/DC,
supply voltage: 24V AC/DC
<
Multifunction
<
Frequency range 16,6 to 400Hz
<
Fault latch
<
Supply voltage selectable via PowerModules or by zoom voltage 24-240V
<
1 CO contact; 2 CO contacts
<
Width 22,5mm
<
Industrial design
Connections
G2IM10AL20 24-240V
G2IM10AL20
G2IM5AL20 24-240V
24VAC/DC
Current monitoring in 1-phase mains
types
G2IM5AL20
G2IM5AL10
G2IM2AL20 24-240V
Art.No. (PQ1)
2390405
2390401
2390417
Art.No. (PQ10)
-
-
-
900866200268
900866200264
9008662006164
Measured variable
Current AC/DCAC Sinus (16,6 to 400Hz)
Current AC/DC
AC Sinus (16,6 to 400Hz)
Current AC/DC
AC Sinus (16,6 to 400Hz)
Measuring ranges
20mA AC/DC; terminals K-I1(+)1A AC/
DC; terminals K-I2(+)5A AC/DC; terminals
K-I3(+)
20mA AC/DC; terminals K-I1(+)
1A AC/DC; terminals K-I2(+)
5A AC/DC; terminals K-I3(+)
800mA AC/DC; terminals K-I1(+)
1,5A AC/DC; terminals K-I2(+)
2A AC/DC; terminals K-I3(+)
Start • max • min • Delay • Function
Start • max • min • Delay • Function
Start • max • min • Delay • Function
U/t • max • min • R
U/t • max • min • R
U/t • max • min • R
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
OVER
OVER+Latch
UNDER
UNDER + Latch
WIN
WIN+Latch
OVER
OVER+Latch
UNDER
UNDER + Latch
WIN
WIN+Latch
Switching threshold max.
10% to 100% from IN
10% to 100% from IN
30% to 100% from IN
Switching threshold min.
5% to 95% from IN
5% to 95% from IN
25% to 95% from IN
0,1s to 10s
0,1s to 10s
0,1s to 10s
24VAC/DC
15
15
25
16 18
26 28
16 18
25
15
25
16 18
26 28
26 28
EAN13-Code
Width 22,5mm
Dimensions
Controls
Indicators (LEDs)
Functions
Tripping delay
Start-up suppression time
0s to 10s
0s to 10s
0s to 10s
Fault latch
selectable
selectable
selectable
Supply
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
24-240V
terminals A1-A2
Output
2 CO contacts250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Width
Certiicates
Mechanical
design
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 34
22,5mm
CE • cULus • GOST
PowerModulee TR2 (12 to 440V AC) • DC power supply SNT2 24V DC • Current Transformers Series DSW and WSW • sealable intervention
protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 35
OVER
UNDER
WIN
Overcurrent monitoring
Undercurrent monitoring
Monitoring the window between Min and Max
OVER+Latch
UNDER+Latch
WIN+Latch
Overcurrent monitoring with fault latch
Undercurrent monitoring with fault latch
Monitoring the window between Min and Max with fault latch
Measuring range 20mA AC/DC,
supply voltage: 24V AC/DC
Measuring range 5A AC/DC with
Powermodule 400V AC
Sensing & Monitoring Relays Series GAMMA
Functions
Current monitoring in 1-phase mains
<
Overcurrent monitoring (G2IO)
<
UNDERcurrent monitoring (G2IU)
<
Supply voltage via PowerModules or DC power supply
<
1 CO contact
<
Width 22,5mm
<
Industrial design
types
G2IO10A10
G2IO5A10
G2IU10A10
G2IU5A10
Art.No. (PQ1)
2390408
2390403
2390409
2390404
Art.No. (PQ10)
-
-
-
-
900866200271
900866200266
900866200272
900866200267
Measured variable
Current AC/DC
AC Sinus (48 to 63Hz)
Current AC/DCAC Sinus (48 to
63Hz)
Current AC/DC
AC Sinus (48 to 63Hz)
Current AC/DC
AC Sinus (48 to 63Hz)
Measuring ranges
100mA AC/DC; terminals K-I1(+)
1A AC/DC; terminals K-I2(+)
10A AC/DC; terminals K-I3(+)
20mA AC/DC; terminals K-I1(+)
1A AC/DC; terminals K-I2(+)
5A AC/DC; terminals K-I3(+)
100mA AC/DC; terminals K-I1(+)
1A AC/DC; terminals K-I2(+)
10A AC/DC; terminals K-I3(+)
20mA AC/DC; terminals K-I1(+)
1A AC/DC; terminals K-I2(+)
5A AC/DC; terminals K-I3(+)
Controls
max • min • Delay
max • min • Delay
max • min • Delay
max • min • Delay
Indicators (LEDs)
U • max • min • R
U • max • min • R
U • max • min • R
U • max • min • R
OVER
OVER
UNDER
UNDER
Switching threshold max.
10% to 100% from IN
10% to 100% from IN
10% to 100% from IN
10% to 100% from IN
Switching threshold min.
5% to 95% from IN
5% to 95% from IN
5% to 95% from IN
5% to 95% from IN
0,2s to 10s
0,2s to 10s
0,2s to 10s
0,2s to 10s
-
-
-
-
Connections
Measuring range 2A AC/DC,
supply voltage: 24V AC/DC
G2IM5AL20
G2IM5AL10
G2IM2AL20 24-240V
24VAC/DC
15
25
15
25
16 18
26 28
16 18
26 28
EAN13-Code
Width 22.5mm
Dimensions
Functions
Tripping delay
Start-up
suppression time
Fault latch
-
-
-
-
Supply
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
Output
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Width
22,5mm
22,5mm
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Certiicates
Mechanical
design
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 36
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
PowerModules TR2 (12 to 440V AC) • DC power supply SNT2 24V DC • Current Transformers Series DSW and WSW • sealable intervention
protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 37
OVER
UNDER
Measured range 20mA with Powermodule 24V AC
Sensing & Monitoring Relays Series GAMMA
Functions
Overcurrent monitoring
Undercurrent monitoring
Measured range 1A with Powermodule 230V AC
Current monitoring in 3-phase mains
<
Multifunction
<
Fault latch
<
Supply voltage selectable via PowerModules or by zoom voltage 24 to 240V AC/DC
<
2 CO contacts
<
Width 22,5mm
<
Industrial design
Connections
G2IO5A10
G2IU5A10
G2IO10A10
G2IU10A10
types
G2JM5AL20 24-240V
G2JM5AL20
Art.No. (PQ1)
2390801
2390800
Art.No. (PQ10)
-
-
900866200294
900866200293
Current 3~
AC Sinus (48 to 63Hz)
Current 3~
AC Sinus (48 to 63Hz)
5A AC
terminals K-I1, K-I2, K-I3
5A AC
terminals K-I1, K-I2, K-I3
Start • max • min • Delay • Function
Start • max • min • Delay • Function
U/t • max • min • R
U/t • max • min • R
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
10% to 100% from IN
10% to 100% from IN
5% to 95% from IN
5% to 95% from IN
0,1s to 10s
0,1s to 10s
0s to 10s
0s to 10s
EAN13-Code
Measured variable
Width 22,5mm
Dimensions
Measured range
Controls
Indicators (LEDs)
Functions
Switching
threshold max.
Switching threshold min.
Tripping delay
Start-up suppression time
Fault latch
selectable
selectable
Supply
24 to 240V AC/DC
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
Width
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
Certiicates
Mechanical
design
Page 38
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
PowerModulees TR2 (12 to 440V AC) • DC power supply SNT2 24V DC • Current Transformers Series DSW and WSW • sealable intervention
protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 39
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
G2JM5AL20, Supply 230V AC and Current Transformers
Sensing & Monitoring Relays Series GAMMA
Functions
Overcurrent monitoring
Overcurrent monitoring with fault latch
Undercurrent monitoring
Undercurrent monitoring with fault latch
Monitoring the window between Min and Max
Monitoring the window between Min and Max with fault latch
G2JM5AL20, Supply 24-240V AC/DC without fault latch
L1 L2 L3 N
Temperature monitoring
<
Temperature monitoring by PT100 probes (2- and 3-wire connection)
<
Multifunction
<
Monitoring of short circuit or line break of sensor line
<
Fault latch
<
Supply voltage by zoom voltage 24 to 240V AC/DC
<
2 CO contacts
<
Width 22,5mm
<
Industrial design
Connections
Load
types
L1
L2
L3
N
G2TMPT100L20 24-240V
24-240V~
0V
A1 K
I1 I2
A1 K
I1 I2
15
16 18
L1 L2 L3 N
Load
15
I3
15
I3
15
25
16 18
26 28
25
26 28
25 26 28
16 18 A2
25 26 28
16 18 A2
Art.No. (PQ1)
2390904
Art.No. (PQ10)
900866200295
EAN13-Code
Measured variable
G2JM5AL20, Supply 230V AC and fault latch
Temperature monitoring PT100
2- and 3-wire connection
Connections
Measured range
-50°C to +200°C
terminals T1-T2-T3
L1 L2 L3 N
Start • max • min • Offset • Function
Controls
U/t • max • min • Sense • R
Indicators (LEDs)
Functions
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
Reset
A1 K
I1 I2
15
16 18
15
I3
Switching
threshold max.
Switching threshold min.
25
-45°C to +200°C
-50°C to 195°C
Tripping delay
26 28
-
Start-up suppression time
L1 L2 L3 N
Last
Width 22,5mm
25 26 28
16 18 A2
0min to 30min
Fault latch
Dimensions
selectable
Supply
24 to 240V AC/DC
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
Width
22,5mm
Certiicates
Mechanical
design
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 40
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 41
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
2-wire conncetion, Supply 24V AC/DC and fault latch
24V
0V
3-wire conncetion, Supply 230V AC without fault latch
Connections
Temperature monitoring
<
Temperature monitoring of the motor winding in accordance with DIN 44081
<
Maximal 6 PTC probes
<
Fault latch
<
Short circuit monitoring of the PTC Input (G2TFKN02)
<
Testfunction with integrated Test/Reset button; possibility for external reset
<
Supply voltage selectable via PowerModules or by zoom voltage 24 to 240VAC/DC
<
1 CO contact; 2 CO contacts
<
Width 22,5mm
<
Industrial design
types
G2TFKN02
24-240V
G2TFKN02
G2TF02 24-240V
G2TF02
Art.No. (PQ1)
2390110
2390101
2390111
2390100
Art.No. (PQ10)
-
-
-
-
900866200251
900866200237
900866200252
900866200236
PTC (motortemperature)
max. 6 PTC probes
PTC (motortemperature)
max. 6 PTC probes
PTC (motortemperature)
max. 6 PTC probes
PTC (motortemperature)
max. 6 PTC probes
total resistance cold <1,5kΩ
terminals T1-T2
total resistance cold <1,5kΩ
terminals T1-T2
total resistance cold <1,5kΩ
terminals T1-T2
total resistance cold <1,5kΩ
terminals T1-T2
≤2,5V DC at R ≤4.0kΩ
(DINVDE 0660 part 302)
≤2,5V DC at R ≤4,0kΩ
(DINVDE 0660 part 302)
≤2,5V DC at R ≤4,0kΩ
(DINVDE 0660 part 302)
≤2,5V DC at R ≤4,0kΩ
(DINVDE 0660 part 302)
Test/Reset button • Function
Test/Reset button • Function
Test/Reset button
Test/Reset button
U • Failure • R
U • Failure • R
U • Failure
U • Failure
Overtemperature
selectable functions:
+K (short circuit monitoring)
+N (remanent latch function)
+K+N (short circuit monitoring
and remanent latch function)
Overtemperature
selectable functions:
+K (short circuit monitoring)
+N (remanent latch function)
+K+N (short circuit monitoring
and remanent latch function)
Overtemperature
Overtemperature
Response value
3,6kΩ
3,6kΩ
3,6kΩ
3,6kΩ
Release value
1,8kΩ
1,8kΩ
1,8kΩ
1,8kΩ
230V AC
L1
N
Reset
Sensing & Monitoring Relays Series GAMMA
Functions
Monitoring of overtemperature
Monitoring of overtemperature with fault latch
Monitoring of undertemperature
Monitoring of undertemperature with fault latch
Monitoring the window between Min and Max
Monitoring the window between Min and Max with fault latch
Pt100
Pt100
T3
T1 T2
T3
T1 T2
15
25
15
25
16 18
26 28
16 18
26 28
EAN13-Code
Measured variable
Width 22,5mm
Dimensions
Measured range
Measuring voltage
Controls
Indicators (LEDs)
Functions
Short circuit monitoring
<20Ω
<20Ω
-
-
yes (auto)
yes (auto)
yes (auto)
yes (auto)
Reset
internal or external
terminals R-T2
internal or external
terminals R-T2
internal or external
terminals R-T2
internal or external
terminals R-T2
Supply
24 to 240V AC/DC
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
24-240V AC/DC
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
Width
22,5mm
22,5mm
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Fault latch
Certiicates
Mechanical
design
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 42
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
PowerModulees TR2 (12 to 440V AC) • DC power supply SNT2 24V DC • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 43
Temperature monitoring of the motor winding (max. 6 PTC) with fault latch, for temperature probes in accordance with DIN 44081, test
function with integrated test/reset key and the following additional functions (G2TFKN02):
Off
+K
+N
+K+N
Basic function
Short circuit monitoring of thermistor line
Zero-voltage latch
Short circuit monitoring and zero-voltage latch
G2TF01
G2TFKN02
Sensing & Monitoring Relays Series GAMMA
Functions
Connections
Temperature monitoring
<
Temperature monitoring of the motor winding in accordance with DIN 44081
<
Maximal 6 PTC probes
<
Fault latch
<
Testfunction with integrated Test/Reset button
<
Possibility for external reset
<
Supply voltage selectable via PowerModules or by zoom voltage 24 to 240V AC/DC
<
1 CO contact; 2 CO contacts
<
Width 22,5mm
<
Industrial design
G2TF02 230V AC
G2TF02 110V AC
G2TF01
Art.No. (PQ1)
2390104
2390109
2390103
2390102
Art.No. (PQ10)
-
-
-
2390102A
900866200241
900866200249
900866200240
900866200238
PTC (motortemperature)
max. 6 PTC probes
PTC (motortemperature)
max. 6 PTC probes
PTC (motortemperature)
max. 6 PTC probes
PTC (motortemperature)
max. 6 PTC probes
total resistance cold <1,5kΩ
terminals T1-T2
total resistance cold <1,5kΩ
terminals T1-T2
total resistance cold <1,5kWterminals T1-T2
total resistance cold <1,5kWterminals T1-T2
≤2,5V DC at R ≤4,0kΩ
(DINVDE 0660 part 302)
≤2,5V DC at R ≤4,0kΩ
(DINVDE 0660 part 302)
≤2,5V DC at R ≤4,0kW(DINVDE
0660 Part 302)
≤2,5V DC at R ≤4,0kW(DINVDE
0660 Part 302)
Test/Reset button
Test/Reset button
Test/Reset button
Test/Reset button
U • Failure
U • Failure
U • Failure
U • Failure
Overtemperature
Overtemperature
Overtemperature
Overtemperature
Response value
3,6kΩ
3.6kΩ
3,6kΩ
3,6kΩ
Release value
Short circuit
monitoring
Fault latch
1,8kΩ
1.8kΩ
1,8kΩ
1,8kΩ
-
-
-
-
types
EAN13-Code
automatic reset by wire link R-T2
Width 22,5mm
automatic reset by wire link R-T2
Measured variable
Dimensions
Measured range
Measuring voltage
Controls
Indicators (LEDs)
Functions
yes (auto)
yes (auto)
yes (auto)
yes (auto)
Reset
internal or external
terminals R-T2
internal or external
terminals R-T2
internal or external
terminals R-T2
internal or external
terminals R-T2
Supply
230V AC
terminals A1-A2
110V AC
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
230V AC
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Width
22,5mm
22,5mm
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Certiicates
Mechanical
design
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 44
G2TF01 230V AC
PowerModulees TR2 (12 to 440V AC) • DC power supply SNT2 24V DC • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 45
Temperature monitoring of motor winding (max. 6 PTC) with fault latch for probes in accordance with DIN 44081,
testfunction with integrated Test/Reset button.
G2TF02
Sensing & Monitoring Relays Series GAMMA
Functions
Level monitoring
<
Level monitoring of conductive substances
<
Pump up or minimum monitoring
<
Pump down or maximum monitoring
<
Secure galvanic separation of measuring circuit
<
2 CO contacts
<
Width 22,5mm
<
Industrial design
Connections
types
automatic reset by wire link R-T2
Width 22,5mm
G2LM20 24V AC
G2LM20 110V AC
G2LM20 230V AC
Art.No. (PQ1)
2390201
2390202
2390200
Art.No. (PQ10)
-
-
-
EAN13-Code
900866200254
900866200255
900866200253
Measured variable
level with
conductiv probe
level with
conductiv probe
level with
conductiv probe
Measured range
0,25 to 100kΩ
0,25 to 100kΩ
0,25 to 100kΩ
Probe voltage
max. 16V AC
max. 16V AC
max. 16V AC
Probe current
max. 7mA
max. 7mA
max. 7mA
max. 1000m (adjustment <50%)
max. 100m (adjustment <100%)
capacity of cable 100nF/km
max. 1000m (adjustment <50%)
max. 100m (adjustment <100%)
capacity of cable 100nF/km
max. 1000m (adjustment <50%)
max. 100m (adjustment <100%)
capacity of cable 100nF/km
Delay on • Delay off • Sensitivity • Function
Delay on • Delay off • Sensitivity • Function
Delay on • Delay off • Sensitivity • Function
Dimensions
Wiring distance
Control
Indicators (LEDs)
Functions
U•R
U•R
Pump up
Pump down
Pump up
Pump down
0,25 to 100 kΩ (Sensitivity)
0,25 to 100 kΩ (Sensitivity)
0,25 to 100 kΩ (Sensitivity)
Tripping delay
0,5s to 10s
0,5s to 10s
0,5s to 10s
Turn-off delay
0,5s to 10s
0,5s to 10s
0,5s to 10s
Supply
24V AC
terminals A1-A2
110V AC
terminals A1-A2
230V AC
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
Trigger level
Width
Certiicates
Mechanical
design
22.5mm
22.5mm
22.5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 46
U•R
Pump up
Pump down
conductive probes (types SK1, SK2, SK3) • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 47
Level monitoring of conductive substances, timing for tripping delay and turn-off delay separately adjustable and the following functions:
Pump up
Pump down
Sensing & Monitoring Relays Series TREND
Functions
Pump up or minimum monitoring
Pump down or maximum monitoring
Voltage monitoring in 3-phase mains
<
Windowfunction (TPW...VN4X)
<
Windowfunction with integrated phase sequence monitoring (TPW...VSN4X)
<
Connection of neutral wire optional
<
Supply voltage selectable via PowerModules or DC power supply
<
1 CO contact
<
Width 45mm
<
Industrial design
Connections
G2LM20
L1
N
types
TPW400VSN4X
TPW230VSN4X
TPW115VSN4X
TPW400VN4X
Art.No. (PQ1)
2400008
2401310
2401210
2401410
Art.No. (PQ10)
-
-
-
-
900866200298
900866200304
900866200303
900866200305
Measured variable
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
Measured range
UN = 400/230V
terminals (N)-L1-L2-L3
UN = 230/133V
terminals (N)-L1-L2-L3
UN = 115/66V
terminals (N)-L1-L2-L3
UN = 400/230V
terminals (N)-L1-L2-L3
max • min • Delay (t1)
max • min • Delay (t1)
max • min • Delay (t1)
max • min • Delay (t1)
max • R • min
max • R • min
max • R • min
max • R • min
A1 15 25
E1 E2 E3
Probe max.
15
16
25
18 26
28
26 28
16 18 A2
Probe min.
Mass
EAN13-Code
Width 22,5mm
Dimensions
Controls
Indicators (LEDs)
Functions
WIN+SEQ
WIN+SEQ
WIN+SEQ
WIN
Asymmetry
crabwise by Umin/Umax
crabwise by Umin/Umax
crabwise by Umin/Umax
crabwise by Umin/Umax
Switching threshold max.
-20% to 30% from UN
-20% to 30% from UN
-20% to 30% from UN
-20% to 30% from UN
Switching threshold min.
-30% to 20% from UN
-30% to 20% from UN
-30% to 20% from UN
-30% to 20% from UN
0,1s to 10s
0,1s to 10s
0,1s to 10s
0,1s to 10s
-
-
-
-
Tripping delay
Start-up suppression time
Fault latch
-
-
-
-
Supply
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
Output
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Width
45mm
45mm
45mm
45mm
CE
CE
CE
CE
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 48
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² flexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 3 (in accordance with IEC 60664-1)
PowerModulees TR2 (12 to 440V AC) • DC power supply SNT2 24V DC
w w w. tel e-o n l i n e. co m
Page 49
Voltage monitoring in 3-phase mains with adjustable setpoints, adjustable tripping delay and phase sequence monitoring.
WIN
WIN+SEQ
Monitoring the window between Min and Max
Monitoring the window between Min and Max and phase sequence monitoring
TPW...N4X; TPW...SN4X
Sensing & Monitoring Relays Series TREND
Functions
Voltage monitoring in 3-phase mains
<
Phase sequence, phase loss and asymmetry monitoring with ixed asymmetry
<
No connection of neutral wire required
<
1 CO contact
<
Width 45mm
<
Industrial design
Connections
TPF230VS4X
TPF400VS4X
Art.No. (PQ1)
2442153
2402058
Art.No. (PQ10)
-
-
900866200315
900866200306
3~
AC Sinus (48 to 63Hz)
3~
AC Sinus (48 to 63Hz)
UN = 230V/132V
terminals L1-L2-L3
UN = 400V/230V
terminals L1-L2-L3
types
EAN13-Code
Measured variable
Width 45mm
Dimensions
Measured range
Controls
-
-
Indicators (LEDs)
R
R
Monitoring of phase sequence
and phase failure
Monitoring of phase sequence
and phase failure
ixed, approx. 10%
ixed, approx. 10%
-
-
-
-
Tripping delay
-
-
Start-up suppression time
-
-
Fault latch
-
-
Supply
= measuring voltage; 3~ 230V ±15%
terminals L1-L2-L3
= measuring voltage; 3~ 400V ±15%
terminals L1-L2-L3
Output
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Width
45mm
45mm
CE
CE
Functions
Asymmetry
Switching threshold max.
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 50
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² flexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 3 (in accordance with IEC 60664-1)
-
w w w. tel e-o n l i n e. co m
Page 51
Phase sequence, phase loss and asymmetry monitoring with fixed asymmetry, no connection of neutral wire necessary.
TPF...S4X
Sensing & Monitoring Relays Series TREND
Functions
Connections
Voltage monitoring in 1-phase mains
<
Windowfunction or reverse Windowfunction (TUW4X)
<
1 trigger level with adjustable hysteresis OVER/UNDER (TUH4X)
<
Position of output relay selectable
<
DIP-Switch for adjusting to AC/DC monitoring and relay position
<
Fault latch
<
Supply voltage selectable via PowerModules or DC power supply
<
1 CO contact
<
Width 45mm
<
Industrial design
types
TUW4X
TUH4X
Art.No. (PQ1)
2420510
2422510
Art.No. (PQ10)
-
-
900866200308
900866200309
Voltage AC/DC
AC Sinus (48 to 63Hz)
Voltage AC/DC
AC Sinus (48 to 63Hz)
24V AC/DC; terminals E1-F1(+)
115V AC/DC; terminals E1-F2(+)
230V AC/DC; terminals E1-F3(+)
440V AC/DC; terminals E2-F3(+)
30V AC/DC; terminals E1-F1(+)
60V AC/DC; terminals E1-F2(+)
300V AC/DC; terminals E1-F3(+)
600V AC/DC; terminals E2-F3(+)
max • min • Delay (t1) • Start (t2) • AC/DC • REL/R̄ĒL̄ • Start On/Off
US • Hyst • Delay (t1) • Start (t2) • AC/DC • REL/R̄ĒL̄ • Start On/Off
EAN13-Code
Measured variable
Width 45mm
Dimensions
Measuring ranges (UN)
Controls
Indicators (LEDs)
Functions
Switching threshold max.
U•R
1 trigger level with hysteresis (OVER/UNDER)
-20% to 30% from UN
trigger level US: 10% to 100% from UN
-30% to 20% from UN
Hysteresis: 5% to 50% from US
Tripping delay
t1 = 0,1s to 10s
t1 = 0,1s to 10s
Start-up suppression time
t2 = 0,1s to 10s
t2 = 0,1s to 10s
Fault latch
selectable
selectable
Supply
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
Output
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Width
45mm
45mm
CE
CE
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 52
max • R • min
WIN • reverse WIN
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² flexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 3 (in accordance with IEC 60664-1)
PowerModulees TR2 (12 to 440V AC) • DC power supply SNT2 24V DC
w w w. tel e-o n l i n e. co m
Page 53
TUW:
AC/DC voltage monitoring in 1-phase mains with adjustable thresholds, timing for start-up suppression and tripping delay separately adjustable and the following functions (selectable by means of DIP switch)
DIP-Switch 1:
DIP-Switch 2:
DIP-Switch 3:
Sensing & Monitoring Relays Series TREND
Functions
AC/DC preselection
Monitoring inside (W) or outside (R) the window between Umin and Umax
ON
Relay picks up during the start-up suppression time (t2)
OFF Relay remains in off position during the start-up suppression time (t2)
Current monitoring in 1-phase mains
<
Windowfunction (TIW4X)
<
2 trigger level (TIF)
<
Hysteresis OVER/UNDER (TIH4X)
TUH:
AC/DC overvoltage monitoring in 1-phase mains with adjustable threshold, timing for start-up suppression and tripping delay separately
adjustable and adjustable hysteresis and the following functions (selectable by means of DIP-switch)
<
Position of output relay selectable (TIW4X; TIH4X)
<
DIP-Switch for adjusting to AC/DC monitoring and relay position (TIW4X; TIH4X)
DIP-Switch 1:
DIP-Switch 2:
DIP-Switch 3:
<
Fault latch (TIW4X; TIH4X)
<
Permsibble continous load on measuring input 15A(TIF)
<
Supply voltage selectable via PowerModules or DC power supply (TIW4X; TIH4X)
<
1 CO contact; 2 CO contacts; Width 45mm; Industrial design
TUW
AC/DC preselection
REL relay in on-position if error occurs R̄ĒL̄ relais in off-position if error occurs
ON
Relay pics up during the start-up suppression time (t2)
OFF
Relay remains in off position during the start-up suppression time (t2)
Connections
TUH
TIW4X
TIH4X
TIF30-300mAAC4X
Art.No. (PQ1)
2430890
2432610
2432894
Art.No. (PQ10)
-
-
-
900866200311
900866200312
900866200313
Measured variable
Current AC/DC
AC Sinus (48 to 63Hz)
Current AC/DC
AC Sinus (48 to 63Hz)
Current AC
AC Sinus (48 to 63Hz)
Measuring ranges
100mA AC/DC; terminals K-I3(+)
1A AC/DC; terminals K-I2(+)
10A AC/DC; terminals K-I1(+)
100mA AC/DC; terminals K-I3(+)
1A AC/DC; terminals K-I2(+)
10A AC/DC; terminals K-I1(+)
15A AC; terminals K-I
max • min • Delay (t1) • Start (t2) • AC/DC •
REL/R̄ĒL̄ • Start On/Off
IS • Hyst • Delay (t1) • Start (t2) • AC/DC •
REL/R̄ĒL̄ • Start On/Off
-
types
- + + +
EAN13-Code
Width 45mm
Dimensions
Controls
max • R • min
U•R
U•R
WIN
1 trigger level with hysteresis (OVER/UNDER)
UNDER
10% to 100% from IN
trigger level IS: 10% to 100% from IN
ixed, 30mA
ixed, 300mA
5% to 50% from IN
Hysteresis: 5% to 50% from IS
Hysteresis: ixeded, approx. 5%
Tripping delay
t1 = 0,1s to 10s
t1 = 0,1s to 10s
-
Start-up suppression time
t2 = 0,1s to 10s
t2 = 0,1s to 10s
-
selectable
selectable
-
Supply
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
230V AC
terminals A1-A2
Output
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
2 CO contacts
250V, 5A AC
Width
45mm
45mm
45mm
CE
CE
CE
Indicators (LEDs)
Functions
Switching threshold max.
Fault latch
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 54
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² flexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 3 (in accordance with IEC 60664-1)
PowerModulees TR2 (12 to 440V AC) • DC power supply SNT2 24V DC • Current Transformers DWS and WSW
w w w. tel e-o n l i n e. co m
Page 55
TIW: AC/DC current monitoring in 1-phase mains with adjustable thresholds, timing for start-up suppression and tripping delay separately
adjustable and the following functions (selectable by means of DIP-switch)
DIP-Switch 1:
DIP-Switch 2:
DIP-Switch 3:
AC/DC preselection
W
Monitoring inside (W) the window between Imin and Imax
R
Monitoringoutside (R) the window between Imin and Imax
ON
Relay pics up during the start-up suppression time (t2)
OFF Relay remains in off position during the start-up suppression time (t2)
TIH: AC/DC overcurrent monitoring in 1-phase mains with adjustable threshold, timing for start-up suppression and tripping delay separately adjustable and adjustable hysteresis and the following functions (selectable by means of DIP-switch)
DIP-Switch 1:
DIP-Switch 2:
DIP-Switch 3:
AC/DC preselection
REL relay in on-position if error occurs. R̄ĒL̄ relais in off-position if error occurs
ON
Relay pics up during the start-up suppression time (t2)
OFF Relay remains in off position during the start-up suppression time (t2)
TIF: Consumer failure detection for AC-current in 1-phase mains with 2 fixeded thresholds (selectable via bridge X1-X2)
TIW4X; TIH4X
TIF30-300mAAC4X
Sensing & Monitoring Relays Series TREND
Functions
Temperature monitoring
<
Temperature monitoring of motor winding
<
Maximum of 6 PTC probes per measuring ciurcit
<
2 measuring circuits (TDT4X)
<
Fault latch for measuring circuit 2 (TDT4X)
<
Short circuit monitoring of PTC circuits
<
Supply voltage selectable via PowerModules or DC power supply (TDT4X)
<
1 NO contact; 1 CO contact per measuring circuit (TDT4X)
<
Width 22,5mm or 45mm
<
Industrial design
Connections
types
TDT4X
TT2X 24V AC
TT2X 230V AC
Art.No. (PQ1)
2480090
2480052
2480054
Art.No. (PQ10)
-
-
-
900866200328
900866200325
900866200327
Measured variable
2 x PTC (motortemperature)
max. 2 x 6 PTC probes
PTC (motortemperature)
max. 6 PTC probes
PTC (motortemperature)
max. 6 PTC probes
Measured range
total resistance cold <1.5kΩ
terminals 1T1-T2 (circuit 1)
terminals 2T1-T2 (circuit 2)
total resistance cold <1.5kΩ
terminals T1-T2
total resistance cold <1.5kΩ
terminals T1-T2
max. 12V DC
max. 12V DC
max. 12V DC
EAN13-Code
Width 45mm
Dimensions
Measuring voltage
Controls
Indicators (LEDs)
Functions
-
-
U • Failure
U • Failure
Overtemperature
Overtemperature
Overtemperature
Response value
3,3kΩ
3,3kΩ
3,3kΩ
Release value
1,8kΩ
1,8kΩ
1,8kΩ
<15Ω
Short circuit monitoring
<15Ω
<15Ω
yes (circuit 2)
-
-
Reset
internal or external
terminals 2R1-T2/2R2
-
-
Supply
PowerModule TR2 or SNT2
terminals A1-A2
24V AC
terminals A1-A2
230V AC
terminals A1-A2
Output
1 CO contact each circuit
250V, 5A AC
1 NO contact
250V, 5A AC
1 NO contact
250V, 5A AC
Width
45mm
22,5mm
22,5mm
CE
CE
CE
Fault latch
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 56
Test/Reset button
U • Failure 1T1-T2 •
Failure 2T1-T2
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² flexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 3 (in accordance with IEC 60664-1)
PowerModulees TR2 (12 to 440V AC) • DC power supply SNT2 24V DC
w w w. tel e-o n l i n e. co m
Page 57
Temperature monitoring of motor winding (max. 6 PTC) with fault latch (only measuring circuit 2) for probes in accordance with DIN 44081
Short circuit monitoring of PTC circuits
TDT4X
TT2X
Sensing & Monitoring Relays Series TREND
Functions
Level monitoring
<
Level monitoring of conductive substances
<
Pump up or minimum monitoring
<
Pump down or maximum monitoring
<
1 CO contact
<
Width 45mm
<
Industrial design
Connections
types
TLH4X 24V AC
TLH4X 230V AC
TLC4X 230V AC
Art.No. (PQ1)
2472012
2472014
2472114
Art.No. (PQ10)
-
-
-
900866200317
900866200318
900866200323
Measured variable
conductiv probe min.
conductiv probe max.
terminals E1-E2-E3
conductiv probe min.
conductiv probe max.
terminals E1-E2-E3
conductiv probe min.
conductiv probe max.
terminals E1-E2-E3
Measuring ranges
EAN13-Code
Width 22,5mm
Width 45mm
Dimensions
0,25 to 5kΩ / 5 to 100kΩ
0,25 to 5kΩ / 5 to 100kΩ
5 to 100kΩ
Probe voltage
max. 16VAC
max. 16VAC
max. 16VAC
Probe current
max. 7mA / max. 200µA
max. 7mA / max. 200µA
max. 200µA
Wiring distance
Control
max. 1000m / max. 100m
max. 100m
Sensitivity • Delay on (t1) • Delay off (t2) •
Function • Measuring ranges
Sensitivity • Function
U•R
U•R
U•R
Pump up
Pump down
Pump up
Pump down
Pump up
Pump down
0,25 to 5kΩ / 5 to 100kΩ
(Sensitivity)
0,25 to 5kΩ / 5 to 100kΩ
(Sensitivity)
5 to 100kΩ
(Sensitivity)
Tripping delay
0,5s to 10s (t1)
0,5s to 10s (t1)
2s ixed
Turn-off delay
Indicators (LEDs)
Functions
Trigger level
0,5s to 10s (t2)
0,5s to 10s (t2)
2s ixed
Supply
24V AC
terminals A1-A2
230V AC
terminals A1-A2
230V AC
terminals A1-A2
Output
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Width
45mm
45mm
45mm
CE
CE
CE
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 58
max. 1000m / max. 100m
Sensitivity • Delay on (t1) • Delay off (t2) •
Function • Measuring ranges
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² flexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 3 (in accordance with IEC 60664-1)
conductive probes (types SK1, SK2, SK3)
w w w. tel e-o n l i n e. co m
Page 59
TLH:
Level monitoring of conductive substances, timing for tripping delay and turn-off delay separately adjustable and the following functions:
Pump down
Pump up
Sensing & Monitoring Relays Series KAPPA
Functions
Pump down or maximum monitoring
Pump up or minimum monitoring
Voltage and current monitoring of mains
<
AC voltage monitoring in 1- and 3-phase mains (K3YM)
<
AC/DC voltage monitoring in 1-phase mains (K3UM)
TLC:
Level monitoring of conductive substances with adjustable threshold, fixeded tripping delay and turn-off delay and the following functions:
<
AC current monitoring in 1-phase mains (K3IM)
<
Monitoring of phase sequence, phase failure and asymmetry (K3PF)
Pump down
Pump up
<
Monitoring of phase failure; monitoring of phase sequence selectable (K3YM)
<
Multifunction (K3YM; K3IM; K3UM)
<
Supply voltage = measuring voltage (K3PF; K3YM; K3UM)
<
Supply voltage = 230V (K3IM)
<
2 CO contacts; Width 38mm; Plug-in mounting
Pump down or maximum monitoring
Pump up or minimum monitoring
Connection of 3-probes (pump up/down)
Connection of 2-probes (Minimum-/Maximum monitoring)
Connections
K3YM400VSY20
K3PF400VSY02
K3UM230VAC02
K3UM24VDC02
K3IM5AACL20 230V
Art.No. (PQ1)
1380402
1380301
1380107
1380106
1380202
Art.No. (PQ10)
-
-
-
-
-
9008662005419
9008662005426
9008662005396
9008662005402
9008662005433
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
Voltage AC
AC Sinus (48 to 63Hz)
Voltage DC
Current AC
AC Sinus (48 to 63Hz)
Measured range
UN = 400/230V
pins (S10)-S5-S6-S7
UN = 400/230V
pins (S10)-S5-S6-S7
230V AC
pins S5-S7
24V DC
pins S5-S7
5A AC
pins S5-S7
Control
ASYM • Max • Min •
Function / Delay
ASYM
Max • Min •
Function
Max • Min • Function
Start • Max • Min •
Function • Delay
Indicators (LEDs)
ASYM • SEQ • Max •
Min • R
U•R
U • Max • Min • R
U • Max • Min • R
U/t • Max • Min • R
UNDER • UNDER+SEQ
• WIN • WIN+SEQ
Monitoring of phase
sequence, phase failure
and asymmetry
UNDER • WIN
UNDER • WIN
OVER • OVER+Latch •
UNDER • UNDER+Latch •
WIN • WIN+Latch
types
EAN13-Code
Measured variable
Width 45mm
Dimensions
Functions
5% to 30%; Off
5% to 30%; Off
-
-
-
Switching threshold max.
80% to 130% of UN
-
80% to 120% of UN
80% to 130% of UN
10% to 100% of IN
Switching threshold min.
5% to 95% of IN
Asymmetry
70% to 120% of UN
-
70% to 110% of UN
75% to 125% of UN
Hysteresis
adjustable
-
adjustable
adjustable
adjustable
Tripping delay
0,1s to 10s
ixed circa 100ms
-
-
0,1s to 10s
Start-up suppression time
-
-
-
-
0s to 10s
Fault latch
-
-
-
-
selectable
Supply
= measuring voltage
3(N)~400/230V
-30% to +30%
pins (S10)-S5-S6-S7
= measuring voltage
3(N)~400/230V
-30% to +30%
pins (S10)-S5-S6-S7
= measuring voltage
230V AC
-30% to +20%
pins S5-S7
= measuring voltage
24V DC
-25% to +30%
pins S5-S7
230V AC
-15% to +10%
pins S2-S10
Output
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
Width
38mm
38mm
38mm
38mm
38mm
CE • GOST
CE • GOST
CE • GOST
CE • GOST
CE • GOST
Certiicates
Mechanical
design
Ambient
conditions
Accessories
Page 60
Self-extinguishing plastic housing, IP rating IP40 • Mounted on 11-pole screw terminal socket in accordance with IEC 60067-1-18a •
Mounting position any
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC
60664-1)
Relay socket R11X, ES12
w w w. tel e-o n l i n e. co m
Page 61
K3YM: Voltage monitoring in 1-phase- and 3-phase mains with adjustable thresholds, adjustable tripping delay, monitoring of phase failure
and monitoring of phase sequence selectable.
K3IM: AC current monitoring in 1-phase mains with adjustable thresholds, adjustable hysteresis and tripping delay.
K3UM: AC/DC voltage monitoring in 1-phase mains with adjustable thresholds and adjustable hysteresis.
K3PF: Monitoring of phase sequence, phase failure and asymmetry with adjustable asymmetry, connection of neutral wire optional.
OVER
UNDER
WIN
OVER+Latch
UNDER+Latch
WIN+Latch
UNDER+SEQ
WIN+SEQ
Overcurrent monitoring
Undercurrent or undervoltage monitoring
Monitoring the window between Min and Max
Overcurrent monitoring with fault latch
Undercurrent monitoring with fault latch
Monitoring the window between Min and Max with fault latch
Undervoltage monitoring and monitoring of phase sequence
Monitoring the window between Min and Max and monitoring of phase sequence
K3UM24VDC02
UN
Voltage monitoring in 3- and 1-phase mains
<
UNDERvoltage monitoring
<
Integrated testswitch (E3YF400VT02 0.85)
<
Start-up delay time in accordance with VDE 0108-100 and VDE 0100-718 (E3YF400VE20 0.85)
<
Supply voltage = measuring voltage
<
2 CO contacts
<
Width 35mm
<
Installation design
Connections
K3UM230VAC02
E(+)
Sensing & Monitoring Relays Series ENYA
Functions
F
E
UN
F
E3YF400V02 0.85
E3YF400VE20 0.85
E3YF400VT02 0.85
E3YF400VT02 HTV 0.85
Art.No. (PQ1)
1341401
1341404
1341402
1341407
Art.No. (PQ10)
-
-
-
-
9008662005303
9008662005785
9008662005297
9008662006416
Measured variable
3N~
AC Sinus (48 to 63Hz)
3N~
AC Sinus (48 to 63Hz)
3N~
AC Sinus (48 to 63Hz)
3N~
AC Sinus (48 to 63Hz)
Measured range
UN = 400/230V
terminals N-L1-L2-L3
UN = 400/230V
terminals N-L1-L2-L3
UN = 400/230V
terminals N-L1-L2-L3
UN = 400/230V
terminals N-L1-L2-L3
types
EAN13-Code
K3IM5AACL20 230V
A2
A1
Connections
K3PF400VSY02
Li
Lk
(N)
L1
L2
L3
IN
UN
Control
-
-
Testfunction
Testfunction
U•R
L1 • L2 • L3 • R
L1 • L2 • L3 • R
L1 • L2 • L3 • R
UNDER
UNDER
UNDER
TEST (R=OFF)
UNDER
TEST (R=OFF)
Asymmetry
-
-
-
-
Switching
threshold max.
-
-
-
-
ixed 195,5V (L-N)
in accordance with
VDE 0100-718
VDE 0108-100
0,85 x UN
ixed 195,5V (L-N)
in accordance with
VDE 0100-718
VDE 0108-100
0,85 x UN
ixed 195,5V (L-N)
in accordance with
VDE 0100-718
VDE 0108-100
0,85 x UN
ixed 195,5V (L-N)
in accordance with
VDE 0100-718
VDE 0108-100
0,85 x UN
Indicators (LEDs)
Functions
Switching
threshold min.
Hysteresis
Tripping delay
Start-up delay time
K3YM400VSY20
(N)
Connections
Width 38mm
L1
L2
Fault latch
51
45
Page 62
38
-
60 sec
-
-
-
-
-
= measuring voltage
3N~400/230V -30% to +10%
terminals N-L1-L2-L3
= measuring voltage
3N~400/230V -30% to +10%
terminals N-L1-L2-L3
= measuring voltage
3N~400/230V -30% to +10%
terminals N-L1-L2-L3
Output
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
Certiicates
Terminal capacity
80
approx. 5%
ixed, approx. 200ms
-
Mechanical
design
47
approx. 5%
ixed, approx. 200ms
= measuring voltage
3N~400/230V -30% to +10%
terminals N-L1-L2-L3
Width
20
approx. 5%
ixed, < 500ms
Supply
Dimensions
L3
approx. 5%
ixed, approx. 200ms
Ambient
conditions
Accessories
35mm
35mm
35mm
35mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
-
w w w. tel e-o n l i n e. co m
Page 63
Sensing & Monitoring Relays Series ENYA
Functions
E3YF400V02 0.85
Undervoltage monitoring in single-phase and 3-phase mains
UNDER
Undervoltage monitoring
E3YF400VT02 0.85
Undervoltage monitoring in single-phase and 3-phase mains
UNDER
Undervoltage monitoring
T
Integrated test switch
E3YF400VE20 0.85
Undervoltage monitoring in single-phase and 3-phase mains
UNDER
Undervoltage monitoring
On delay as per VDE 0100-718
Voltage monitoring in 3- and 1-phase mains
<
Undervoltage monitoring
<
Integrated testswitch (E1YF400VT01 0.85)
<
Supply voltage = measuring voltage
<
1 CO contact
<
Width 17,5mm
<
Installation design
Connections
E3YF
L1
L1
3N~ L2
L3
N
E1YF400V01 0.85
E1YF400VT01 0.85
E1YF400V01 0.70
Art.No. (PQ1)
1340402
1340406
1340410
Art.No. (PQ10)
1340402A
-
-
900866200057
900866200487
9008662006140
Measured variable
3N~
AC Sinus (48 to 63Hz)
3N~
AC Sinus (48 to 63Hz)
3N~
AC Sinus (48 to 63Hz)
Measured range
UN = 400/230V
terminals N-L1-L2-L3
UN = 400/230V
terminals N-L1-L2-L3
UN = 400/230V
terminals N-L1-L2-L3
Type
1~
N
N
L1 L2 L3
N
L1 L2 L3
11
R
21
R
11
R
21
R
12 14
22 24
12 14
22 24
22 21
12 11 14 24
22 21
12 11 14 24
EAN13-Code
E3YF
E3YF
Connections
Control
-
Testfunction
-
Indicators (LEDs)
R
L1 • L2 • L3 • R
R
UNDER
UNDER
TEST (R=OFF)
UNDER
-
-
-
-
-
-
ixed 195,5V (L-N)
in accordance with
VDE 0100-718
VDE 0108-100
0,85 x UN
ixed 195,5V (L-N)
in accordance with
VDE 0100-718
VDE 0108-100
0,85 x UN
ixed 161V (L-N)
45mm
87mm
Functions
Asymmetry
Switching
threshold min.
Switching
threshold min.
5mm
44mm
60mm
35mm
Hysteresis
Tripping delay
Start-up delay time
Width 35mm
Dimensions
Fault latch
ca. 5%
ca. 5%
ixed, ca. 200ms
ixed, ca. 200ms
-
-
-
-
-
-
Supply
= measuring voltage
3N~400/230V -30% to +10%
terminals N-L1-L2-L3
= measuring voltage
3N~400/230V -30% to +10%
terminals N-L1-L2-L3
= measuring voltage
3N~400/230V -30% to +10%
terminals N-L1-L2-L3
Output
1 CO contact
250V, 5A AC
1CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Width
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 64
ca. 5%
ixed, ca. 200ms
17,5mm
17,5mm
17,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end •
2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to +70°C •
relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
-
w w w. tel e-o n l i n e. co m
Page 65
Sensing & Monitoring Relays Serie ENYA
Functions
E1YF400V01 0.85
Voltage monitoring in 1-phase and 3-phase mains
UNDER
Undervoltage monitoring
E1YF400VT01 0.85
Voltage monitoring in 1-phase and 3-phase mains
UNDER
Undervoltage monitoring
T
Integrated testswitch
Voltage monitoring in 3- and 1-phase mains
<
Multifunction
<
Monitoring of phase failure
<
Monitoring of phase sequence selectable
<
Connection ot neutral wire optional
<
Supply voltage = measuring voltage
<
1 CO contact; 2 CO contacts
<
Width 17,5mm; 35mm
<
Installation design
Connections
E1YF
E3YM230VS20
E1YM400VS10
E1YM480Y/277VS10
Art.No. (PQ1)
1340406
1340405
1340409
Art.No. (PQ10)
-
-
-
9008662006393
900866200484
9008662006768
Measured variable
3(N)~
AC Sinus (48 bis 63Hz)
3(N)~
AC Sinus (48 bis 63Hz)
3(N)~
AC Sinus (48 bis 63Hz)
Measured range
UN = 230/132V
terminals (N)-L1-L2-L3
UN = 400/230V
terminals (N)-L1-L2-L3
UN = 480/277V
terminals L1-L2-L3
Delay • Max • Min • Function
Delay • max • min • Function
Delay • max • min • Function
SEQ • Max • Min • R
SEQ • max • min • R
SEQ • max • min • R
UNDER
UNDER+SEQ
WIN
WIN+SEQ
UNDER
UNDER+SEQ
WIN
WIN+SEQ
UNDER
UNDER+SEQ
WIN
WIN+SEQ
types
L1
L2
3N~ L3
1~
N
L
N
N L3
L1 L2
N L3
L1 L2
11
R
11
R
12 14
12 14
11
12 14
11
12 14
EAN13-Code
Dimensions
Width 17,5mm
Control
Indicators (LEDs)
87mm
45mm
Functions
Asymmetry
Switching
threshold min.
5mm
44mm
60mm
17,5mm
Switching
threshold min.
Hysteresis
Tripping delay
-
-
80% to 130% of UN
75% to 110% of UN
70% to 120% of UN
70% to 120% of UN
65% to 100% of UN
-
-
-
0 to 10s
0,1 to 10s
0,1 to 10s
Start-up delay time
-
-
-
Fault latch
-
-
-
Supply
= measuring voltage
3(N)~230/132V -30% to +30%
terminals (N)-L1-L2-L3
= measuring voltage
3(N)~400/230V -30% to +30%
terminals (N)-L1-L2-L3
= measuring voltage
3~480/277V -35% to +10%
terminals L1-L2-L3
Output
2 CO contacts
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Width
35mm
17,5mm
17,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • GOST
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 66
80% to 130% of UN
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end •
2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to +70°C •
relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
-
w w w. tel e-o n l i n e. co m
Page 67
UNDER
UNDER+SEQ
WIN
WIN+SEQ
Undervpltage monitoring
Undervoltage and phase sequence monitoring
Window monitoring, monitoring of range between the min and max thresholds
Monitoring the window between Min and Max and monitoring of phase sequence
Voltage monitoring in 3- and 1-phase mains
<
Undervoltage monitoring
<
Supply voltage = measuring voltage
<
1 CO contact; 2 CO contacts
<
Width 17,5mm; 35mm
<
Installation design
Connections
E3YM230VS20
L1
3N~
Sensing & Monitoring Relays Series ENYA
Functions
E1YM, E3YM
Voltage monitoring in single-phase and 3-phase mains with adjustable thresholds, adjustable trip delay, monitoring of phase breakdown
and phase sequence and the following functions that can be selected via rotary switches:
L1
L2
L3
N
E3YU400V02
E1YU400V01
Art.No. (PQ1)
1341403
1340403
Art.No. (PQ10)
-
-
9008662005617
900866200059
Measured variable
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
Measured range
UN = 400/230V
terminals N-L1-L2-L3
UN = 400/230V
terminals N-L1-L2-L3
types
1~
N
N
N
L1 L2 L3
L1 L2 L3
15
R
25
R
15
R
25
R
16 18
26 28
16 18
26 28
16
26 25
15 18 28
16
26 25
15 18 28
EAN13-Code
E1YM400VS10
Connections
E1YM480Y/277VS10
L
3N~
1~
N
L1
L2
L3
N
3N~
L1
L2
L3
Control
Indicators (LEDs)
Functions
N L3
L1 L2
N L3
L1 L2
15
R
15
R
16 18
16 18
15
16 18
L3
L1 L2
Switching threshold min.
15
R
16 18
15
16 18
Dimensions
Width 35mm
45mm
45mm
87mm
87mm
87mm
87mm
45mm
45mm
Page 68
44mm
60mm
-
160-240V (L-N)
160-240V (L-N)
Start-up suppression time
-
-
Fault latch
-
-
Supply
= measuring voltage
3(N)~400/230V -30% to +10%
terminals (N)-L1-L2-L3
= measuring voltage
3(N)~400/230V -30% to +10%
terminals (N)-L1-L2-L3
Output
2 CO contacts
250V, 5A AC
1 CO contact
250V, 5A AC
Width
Ambient
conditions
Accessories
5mm
-
-
approx. 5%
Terminal capacity
17,5mm
UNDER
-
ixed, approx. 200ms
Mechanical
design
44mm
60mm
UNDER
ixed approx. 200ms
Certiicates
5mm
US
L1 • L2 • L3 • R
approx. 5%
Hysteresis
Tripping delay
15
16 18
Width 17,5mm
Asymmetry
US
L1 • L2 • L3 • R
35mm
17,5mm
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
-
35mm
w w w. tel e-o n l i n e. co m
Page 69
Sensing & Monitoring Relays Series ENYA
Functions
E1YU, E3YU
Undervoltage monitoring in 4-wire systems (each phase against neutral), with adjustable setpoint (E1YU) and with fixed hysteresis.
Voltage monitoring in 3- and 1-phase mains
<
Voltage monitoring in accordance with VDE 0126-1-1
<
Quick net error recognition
<
Supply voltage = measuring voltage
<
2 CO contacts
<
Width 35mm
<
Installation design
Connections
E3YU
L1
L1
3N~ L2
L3
N
E3YF400VFAL02
types
1~
N
N
L1 L2 L3
N
L1 L2 L3
11
R
21
R
11
R
21
R
12 14
22 24
12 14
22 24
12
22 21
11 14 24
12
22 21
11 14 24
Art.No. (PQ1)
1341400
Art.No. (PQ10)
9008662005198
EAN13-Code
3N~
Measured variable
3(N)~
AC Sinus (48 to 63Hz)
Measured range
UN = 400/230V
terminals (N)-L1-L2-L3
Connections
E1YU
L1
L2
L3
N
1~
U/t • R
Indicators (LEDs)
N
N L3
L1 L2
Latch • Average
Control
L
Functions
N L3
L1 L2
11
R
11
R
12 14
12 14
11
12 14
11
12 14
WIN
WIN+LATCH
Asymmetry
ixed +15% from UN
ixed -20% from UN
10-minute-average: +10% to +15% from UN
Switching threshold min.
U ≤ 80% from UN <200ms
U 115% from UN <200ms
phase failure <20ms
Delay
Width 17,5mm
On-delay
ixed 30s
Fault latch
selectable
Supply
= measuring voltage
3(N)~400/230V
terminals (N)-L1-L2-L3
Output
2 CO contacts
250V, 5A AC
Dimensions
Width 35mm
Width
35mm
45mm
87mm
87mm
45mm
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
5mm
44mm
60mm
Page 70
17,5mm
5mm
Accessories
44mm
60mm
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC
60664-1)
-
35mm
w w w. tel e-o n l i n e. co m
Page 71
E3YF400VFAL02
Voltage monitoring in 3-phase mains in accordance with VDE 0126-1-1 with fixed tripping delay, fixed threshold, adjustable 10-minuteaverage and selectable fault latch by means of rotary switch.
Monitoring the fixed adjusted range
Monitoring the fixed adjusted range with fault latch
WIN
WIN+Latch
Sensing & Monitoring Relays Series ENYA
Functions
Voltage monitoring in 3- and 1-phase mains
<
Monitoring of phase sequence, phase failure and asymmetry
<
Connection of neutral wire optional (E1PF400VSY01, E3PF400VSY02)
<
Supply voltage = measuring voltage
<
1 CO contact; 2 CO contacts
<
Width 17,5mm or 35mm
<
Installation design
Connections
E3YF400VFAL02
L1
L1
3N~ L2
L3
N
E3PF400VSY02
E1PF400VSY01
E1PF480Y/277VSY10
Art.No. (PQ1)
1341300
1340300
1340305
Art.No. (PQ10)
-
-
-
900866200513
900866200486
Measured variable
3(N)~
AC Sinus (48 to 63Hz)
3(N)~
AC Sinus (48 to 63Hz)
3~
AC Sinus (48 to 63Hz)
Measured range
UN = 400/230V
terminals (N)-L1-L2-L3
UN = 400/230V
terminals (N)-L1-L2-L3
208V to 480V
terminals L1-L2-L3
Control
ASYM
ASYM
Delay • ASYM
Indicators (LEDs)
U•R
U•R
U • Failure • R
Monitoring of phase sequence, phase failure
and asymmetry
Monitoring of phase sequence, phase failure
and asymmetry
Monitoring of phase sequence, phase failure
and asymmetry
5% to 25%, OFF
5% to 25%; OFF
5% to 25%, OFF
Switching threshold max.
-
-
-
Switching threshold min.
-
-
-
Hysteresis
-
-
-
types
1~
N
N
L1 L2 L3
N
L1 L2 L3
11
R
21
R
11
R
21
R
12 14
22 24
12 14
22 24
22 21
12 11 14 24
22 21
12 11 14 24
EAN13-Code
Dimensions
Width 35mm
45mm
87mm
Functions
Asymmetry
ixed, approx. 100ms
ixed, approx. 100ms
0,1s to 20s
Start-up suppression time
-
-
-
Fault latch
-
-
-
Supply
= measuring voltage
3(N)~400/230V -30% to +30%
terminals (N)-L1-L2-L3
= measuring voltage
3(N)~400/230V -30% to +30%
terminals (N)-L1-L2-L3
= measuring voltage
3~208/120V to 480/277V
-10% to +10% from UN
terminals L1-L2-L3
Output
2 CO contacts
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Tripping delay
5mm
44mm
60mm
35mm
Width
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 72
35mm
17,5mm
17,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC
60664-1)
-
w w w. tel e-o n l i n e. co m
Page 73
E1PF400VSY01
L1
L2
L3
N
3N~
Voltage monitoring in 1-phase mains
<
AC/DC voltage monitoring in 1-phase mains
<
Multifunction (E1UM)
<
Undervoltage monitoring (E1UU)
<
Supply voltage = measuring voltage
<
1 CO contact
<
Width 17,5mm
<
Installation design
Connections
E3PF400VSY02
3N~
Sensing & Monitoring Relays Series ENYA
Functions
E1PF; E3PF
Monitoring of phase sequence, phase failure and asymmetry with adjustable asymmetry, connection of neutral wire optional.
L1
L2
L3
N
N L3
L1 L2
types
N
E1UU230V01
Art.No. (PQ1)
1340101
1340102
Art.No. (PQ10)
-
-
900866200510
900866200505
Measured variable
Voltage AC/DC
AC Sinus (48 to 63Hz)
Voltage AC/DC
AC Sinus (48 to 63Hz)
Measuring ranges
24V DC; terminals E-F1(+)
24V AC; terminals E-F2
230V AC; terminals E-F3
24V DC; terminals E-F1(+)
24V AC; terminals E-F2
230V AC; terminals E-F3
Max • Min • Function
Min
L1 L2 L3
11
R
11
R
21
R
12 14
12 14
22 24
11
12 14
E1UM230V01
22 21
12 11 14 24
EAN13-Code
Dimensions
E1PF480Y/277VSY10
3N~
L1
L2
L3
Controls
U • Max • Min • R
U•R
UNDER
WIN
UNDER
80% to 120% from UN
-
75% to 115% from UN
75% to 115% from UN
adjustable
ixed 5%
Tripping delay
-
-
Start-up suppression time
-
-
Indicators (LEDs)
L3
L1 L2
Functions
Switching threshold max.
Switching
threshold min.
Hysteresis
15
R
16 18
15
16 18
Fault latch
Width 17,5mm
Width 35mm
-
-
Supply
= measuring voltage
24V DC; terminals E-F1(+)
24V AC; terminals E-F2
230V AC; terminals E-F3
-25% to +20%
= measuring voltage
24V DC; terminals E-F1(+)
24V AC; terminals E-F2
230V AC; terminals E-F3
-25% to +20%
Output
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Width
45mm
87mm
87mm
45mm
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
5mm
44mm
60mm
Page 74
17,5mm
5mm
17,5mm
17,5mm
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
-
44mm
60mm
35mm
w w w. tel e-o n l i n e. co m
Page 75
UNDER
WIN
Undervoltage monitoring
Monitoring the window between Min and Max
E1UU
AC/DC UNDERvoltage monitoring in 1-phase mains with adjustable threshold and fixeded hysteresis.
UNDER
Undervoltage monitoring
1~
Current monitoring
<
AC/DC current monitoring (E3IM)
<
AC current monitoring (E1IM; E1IU)
<
Multifunction (E1IM; E3IM)
<
Undercurrent monitoring (E1IU)
<
Supply voltage 230V (E3IM - galvanically separated)
<
1 CO contact; 2 CO contacts
<
Width 17,5mm; 35mm
<
Installation design
Connections
E1UM; E1UU
230V
AC
Sensing & Monitoring Relays Series ENYA
Functions
E1UM
AC/DC voltage monitoring in 1-phase mains with adjustable thresholds and hysteresis.
1~ L
L
24V
AC
N
24V
DC
N
E F1
F3 F2
E F1
F3 F2
+
types
E3IM10AL20
E1IM10AACL10
E1IU5AAC01
E1IU500mAAC01
Art.No. (PQ1)
1341200
1340200
1340201
1340204
Art.No. (PQ10)
-
-
-
-
900866200594
900866200486
900866200504
9008662005341
Measured variable
Current
AC/DC Sinus (16 to 400Hz)
Current
AC Sinus (48 to 63Hz)
Current
AC Sinus (48 to 63Hz)
Current
AC Sinus (48 to 63Hz)
Measuring ranges
100mA AC/DC; terminals k-I1
1A AC/DC; terminals k-I2
10A AC/DC; terminals k-I3
10A AC; terminals Li-Lk
5A AC; terminals Li-Lk
500mA AC; terminals Li-Lk
Controls
Start • Max • Min • Function •
Delay
Delay • Max • Min • Function
IS
IS
Indicators (LEDs)
U/t • Max • Min • R
U/t • Max • Min • R
U•R
U•R
Functions
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
UNDER
UNDER
Switching
threshold max.
Switching
threshold min.
Hysteresis
10% to 100% of IN
10% to 100% of IN
-
-
5% to 95% of IN
5% to 95% of IN
10% to 100% of IN
10% to 100% of IN
adjustable
adjustable
ixed, 10%
ixed, 10%
Tripping delay
0,1s to 10s
0,1s to 10s
-
-
-
E F1
F3 F2
11
R
11
R
11
R
12 14
12 14
12 14
11
12 14
11
12 14
11
12 14
EAN13-Code
Dimensions
5mm
44mm
60mm
87mm
45mm
Width 17,5mm
17,5mm
Start-up suppression time
0s to 10s
-
-
-
Fault latch
selectable
selectable
-
-
Supply
230V AC
terminals A1-A2
-15% to +15%
230V AC
terminals Li-N
-15% to +15%
230V AC
terminals Li-N
-15% to +15%
230V AC
terminals Li-N
-15% to +15%
Output
2 CO contacts
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Width
35mm
17,5mm
17,5mm
17,5mm
CE
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 76
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
Mounting plate MP; Current transformer Series DSW and WSW
w w w. tel e-o n l i n e. co m
Page 77
OVER
UNDER
WIN
OVER+Latch
UNDER+Latch
WIN+Latch
Overcurrent monitoring
Undercurrent monitoring
Monitoring the window between Min and Max
Overcurrent monitoring with fault latch
Undercurrent monitoring with fault latch
Monitoring the window between Min and Max with fault latch
E1IU
AC current monitoring with adjustable threshold and fixed hysteresis.
E1IM
Connections
E1IU
1~
L
1~
N
Li
N
L
Temperature monitoring
<
Temperature monitoring of the motor winding for temperature sensors in accordance with DIN 44081
<
Maximum 6 PTC sensors
<
Short circuit monitoring of the thermistor line (selectable by means of terminals)
<
Optional evaluation of one thermal contact
<
Test function with integrated reset key
<
Rated isolated voltage on the sensor circuit up to 690V
<
1 CO contact
<
Width 35mm
<
Installation design
types
E3TF01
Art.No. (PQ1)
1341600
N
Lk
Li
N
Lk
15
R
11
R
16 18
12 14
15
16
Sensing & Monitoring Relays Series ENYA
Functions
E1IM: DC current monitoring with adjustable thresholds, hysteresis and tripping delay.
E3IM: AC/DC current monitoring with adjustable thresholds, hysteresis and tripping delay.
11
12
18
Art.No. (PQ10)
14
900866200512
EAN13-Code
Measured variable
L
PTC (motortemperature)
max. 6 PTC probes
Connections
E3IM measuring range 100mA; 1A; 10A
Measured range
L
total resistance cold <1,5kΩ
terminals T1-T2 or T1-T3
L
≤7,5V DC by R ≤4,0kΩ
(in accordance with EN 60947-8)
Measuring voltage
N
N
k
I1
15
R
N
A1 A2
I2 I3
A1 A2
I1 I2 I3
k
25
R
15
R
16 18 26 28
k
25
R
Test/Reset button
U • Failure
Functions
25
R
16 18 26 28
26 25
16 15 18 28
Width 17,5mm
A1 A2
I1 I2 I3
15
R
16 18 26 28
26 25
16 15 18 28
Controls
Indicators (LEDs)
26 25
16 15 18 28
Dimensions
Width 35mm
Overtemperature
Response value
≥3,6kΩ
Release value
Short circuit
monitoring
Fault latch
≤1,65kΩ
<20Ω
yes
Reset
internal or external
terminals R1-R2
Supply
230V AC
terminals A1-A2
Output
1 CO contacts
250V, 5A AC
Width
35mm
Certiicates
Mechanical
design
5mm
44mm
60mm
Page 78
17,5mm
45mm
5mm
87mm
87mm
45mm
Terminal capacity
Ambient
conditions
Accessories
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
-
44mm
60mm
35mm
w w w. tel e-o n l i n e. co m
Page 79
E3TF01
Temperature monitoring of the motor winding (max. 6 PTC) with fault latch for temperature sensors in accordance with DIN 44081, short
circuit monitoring of the thermistor line (selectable by means of terminals), integrated test/reset key.
Note:
Only one of this circuit versions (either monitoring of the temperature sensor or monitoring of the thermal contact) can be executed.
Monitoring Temperature sensor
U
A1 A2
T3
T1 T2
A1
Level monitoring
<
Level monitoring of conductive liquids
<
Multifunction
<
Reinforced insulation of the measuring circuit
<
1 CO contact
<
Width 35mm
<
Installation design
Connections
Monitoring Thermal contact
U
T3
Sensing & Monitoring Relays Series ENYA
Functions
types
E3LM10
Art.No. (PQ1)
1341500
A1 A2
T1 T2
11
R
A1
A2 12 14
11
R
A2 12 14
R1 R2
R1 R2
11 12 14
11 12 14
Art.No. (PQ10)
Reset
Reset
-
EAN13-Code
900866200509
Measured variable
level with
conductiv probe
Dimensions
Width 35mm
Measured range
0,25 to 100kΩ
Probe voltage
12V AC
Probe current
max. 7mA
max. 1000m (adjustment <50%)
max. 100m (adjustment <100%)
capacity of cable 100nF/km
45mm
87mm
Wiring distance
Delay ON • Delay OFF • Sensitivity • Function
Control
U•R
Indicators (LEDs)
Functions
Pump up
Pump down
0,25 to 100 kΩ (Sensitivity)
trigger level
5mm
44mm
60mm
35mm
Tripping delay
0,5s to 10s
Turn-off delay
0,5s to 10s
Supply
230V AC
terminals A1-A2
Output
1 CO contact
250V, 5A AC
Width
35mm
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 80
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
Conductive probes (types SK1, SK2, SK3)
w w w. tel e-o n l i n e. co m
Page 81
E3LM10
Level monitoring of conductive liquid, timing for tripping delay and turn-off delay seperatly adjustable and the following functions
(selectable by means of rotary switch):
Pump up
Pump down
Functions
pump up or minimum monitoring
pump down or maximum monitoring
Connections
E3LM
L
N
A1 A2
E1 E2 E3
A1
Sonde
max.
15
R
A2 16 18
16 18 15
Sonde
min.
Massesonde
Dimensions
45mm
5mm
44mm
60mm
Page 82
87mm
With 35mm
35mm
Page 83
LOADMONITOR
“The motor as sensor”: Monitoring motors’ eficiency or effective power
makes it possible to draw a number of useful conclusions regarding the state
of drives, machines and installations, and this can often be used to reduce the
cost of maintenance, servicing and downtime. TELE offers the widest range of
products with the following performance features:
Measurement of one or more quantities such as power factor (cos )
and effective power
Measuring voltages in conventional mains grids at 230/400 V or
240/415 V as well as special industrial power supplies at 400/690 V
Single-phase and three-phase loads
Direct measurement of up to 16 amps with no scaling components
The robust design with generous terminal space throughout plus facilities
for taking measurements downstream from frequency converters together
ensure very good usability and installability.
OVERVIEW
Seite
Selection matrix
Quick, explicit and time-saving to the right product.
Industry Series: GAMMA
- True power monitoring
- Active power transduser
- Active current transducer
- Power factor monitoring
w w w. tel e-o n l i n e. co m
88
89
97
99
101
Page 87
SERIES
Design
GAMMA
Industrie
True power monitors
Current
COS - Monitors
Function
Underload detection






Overload detection






Under- and overload detection (Window)






I=0 (zero current-) detection 2)






Temperature monitoring for motor windings





Conigurable threshold






Conigurable hysteresis
3)
Fault storage
Override on start-up
4)
Tripping delay



































Reduced tripping times
Digital control


















5)
5)
5)
5)
5)
5)
5)
5)








5)
5)
5)
5)
5)
5)
5)
5)



1)
1)




1)
1)



















10A
2A

Outputs

1 CO contact
2 CO contacts






Current rating
16A
16A
12A
12A
12A
12A
12A

12A

12A
Analogue output

12A
15A
420mA
420mA
10A
230/400V AC
230/400V AC
230/400V AC
-
277/480V AC
277/480V AC
230/400V AC
277/480V AC
277/480V AC
277/480V AC
277/480V AC
277/480V AC
400/690V AC
400/690V AC
Measured voltage
12 - 400V AC
12 - 400V AC
12 - 400V AC
24 - 240V AC/DC
24 - 240V AC/DC
12 - 400V AC
12 - 400V AC
12 - 400V AC
12 - 500V AC
12 - 500V AC
24 - 240V AC/DC
12 - 500V AC
12 - 500V AC
12 - 500V AC
Mains voltage
G4BM690V16AL20
G4BM480V12ADTL20
G4BM480V12ADTL20 24-240V AC/DC
G4BM480V12ATL20
G4BM480V12AFTL20
G2BM480V12AFL10
G2BM400V12AL10
G2BM480V12AFL10
G2BA480V12A
G2IA15A
G2CM400V10AL20
G2CM400V2AL20
G2CU400V10AL10
Technical data page
G4BM690V16ATL20
Type
89
89
91
91
93
93
95
95
95
97
99
101
101
101
1) Due to cos characteristics maximum detection is only possible within underload range of the motor.
2) Optional detection of disconnected load. A standby condition of the monitoring relay will be triggered.
3) For two-point controller, the differential gap (hysteresis) can be set separately. It‘s the difference between the upper and lower threshold.
4) Time function which disables an error message during start up; this enables a start-up without shut off from inrush load.
5) Monitoring and controlling functions via PLC.
Page 88
Loadmonitors Series GAMMA
Effective power recording for 1 or 3 phase loads
<
Multifunction
<
Temperature monitoring of the motor coil (G4BM690V16ATL20)
<
Fault memory; reset button
<
Detection of shorted loads I=0
<
Frequency converter suitable (10 to 100Hz)
<
Supply voltage selectable via power module
<
2 CO contacts
<
Width 45mm
<
Industrial design
G4BM690V16ATL20
G4BM690V16AL20
Art.No. (PQ1)
2394720
2394721
Art.No. (PQ10)
-
-
True power consumption 1- or 3-phase Loads
AC Sinus (10 to 400Hz)
True power consumption 1- or 3-phase Loads
AC Sinus (10 to 400Hz)
types
EAN13-Code
Measured variable
2kW • 4kW • 8kW • 16kW
2kW • 4kW • 8kW • 16kW
1-Phase loads: 42 to 690V AC
3-Phase loads: 3~ 42 to 690/400V
1-Phase loads: 42 to 690V AC
3-Phase loads: 3~ 42 to 690/400V
Measuring range 2 and 4kW: 0,2 to 8A
Measuring range 8 and 16kW: 0,4 to 16A
Measuring range 2 and 4kW: 0,2 to 8A
Measuring range 8 and 16kW: 0,4 to 16A
Start • P1 • Delay • Range • Function •
I< • P2 • Reset
Start • P1 • Delay • Range • Function •
I< • P2 • Reset
U/t • Failure P1 • Rel1 • I=0 • Failure P2 • Temp • Rel2
U/t • Failure P1 • Rel1 • I=0 • Failure P2 • Rel2
2MAX
2MIN
WIN
MIN/MAX
I=0 with optionally selectable relay setting
2MAX
2MIN
WIN
MIN/MAX
I=0 with optionally selectable relay setting
P1: 10% to 120% from PN
P2: 5% to 110% from PN
P1: 10% to 120% from PN
P2: 5% to 110% from PN
ixed, ca. 3% from PN
ixed, ca. 3% from PN
Triggering delay
0,1s to 50s
0,1s to 50s
Start-up suppresion time
1s to 100s
1s to 100s
Wire link Y1-Y2
Wire link Y1-Y2
Supply
PowerModule TR3 (12 - 500V AC)
Terminals A1-A2
PowerModule TR3 (12 - 500V AC)
Terminals A1-A2
Output
2 CO contact
250V 5A AC
2 CO contact
250V 5A AC
Measuring range
Measuring voltage
Measuring range Current
Controls
Indicators (LEDs)
Functions
Threshold
Th_A and Th_B
Hysteresis
Fault latch
Width
Certiicates
Mechanical
design
45mm
45mm
CE • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
PowerModules TR3 (12 - 500V AC) • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 89
2MIN
2MAX
WIN
MIN/MAX
Underload monitoring for two independent thresholds
Underload monitoring for two independent thresholds
Monitoring of the threshold level between min and max areas
Underload and overload monitoring for two independent thresholds
I<
Detection of shorted loads with selectable relay setting
Connected 3~ 230/400V with power module 230V AC with fault
latch and temperature monitoring sensor IN<16A
Connected 3~ 400/690V with power module 24V AC without fault
latch IN<16A
Connections
True power monitoring of 1- or 3-phase loads
<
Multifunction
<
Digital setting
<
Temperature monitoring of the motor coil
<
Fault latch
<
Recognition of disconnected load I=0
<
Suitable for VFI (10 to 100Hz)
<
Supply voltage selectable via power modules or zoom voltage 24-240V AC/DC
<
2 CO contact
<
Width 45mm
<
Industrial design
G4BM480V12ADTL20
G4BM480V12ADTL20 24-240V
Art.No. (PQ1)
2394700
2394706
Art.No. (PQ10)
-
-
types
L1
L2
L3
L1
L2
L3
N
Loadmonitors Series GAMMA
Functions
24V~
0V
i
k
A1
L1
i
L3
L2
15
k
A1
L1
25
15
16 18 26 28
25
16 18 26 28
Y1 Y2
15
T1 T2
25
Y1 Y2
15
16
A2
26
28
16
A2
18
L3
L2
18
T1
T2
25
26
28
EAN13-Code
Measured variable
Connected 3~ 400/690V with power module 400V AC with fault
latch and current transformer IN>16A
Connected 3~ 500V with power module 500V AC with fault latch
IN<16A
Connections
Measuring range
Measuring voltage
L1
L2
L3
L1
L2
L3
N
Measuring range Current
Reset
Reset
Controls
i
k
L1
i
A1
L1
L3
L2
15
k
16
18
15
15
25
T1
A2
A1
Functions
L3
L2
25
Threshold
Th_A and Th_B
16 18 26 28
16 18 26 28
Y1 Y2
Indicators (LEDs)
T2
26
Y1 Y2
25
28
16
18
15
A2
T1 T2
26
Hysteresis
25
Triggering delay
28
Start-up suppresion time
Dimensions
90mm
2,5kW and 10kW
1-Phase loads: 0 to 480VAC
3-Phase loads: 3~ 0 to 480/277V
1-Phase loads: 0 to 480VAC
3-Phase loads: 3~ 0 to 480/277V
Measuring ranges 2,5kW: 0,15 to 6A
Measuring ranges 10kW: 0,3 to 12A
Measuring ranges 2,5kW: 0,15 to 6A
Measuring ranges 10kW: 0,3 to 12A
Programming buttons
Programming buttons
Display
Display
OVER • OVER+I=0 ON • UNDER • UNDER+I=0 ON
2MIN • 2MIN+I=0 ON • 2MAX • 2MAX+I=0 ON
WIN • WIN+I=0 ON • MIN/MAX • MIN/MAX+I=0 ON
OVER • OVER+I=0 ON • UNDER • UNDER+I=0 ON
2MIN • 2MIN+I=0 ON • 2MAX • 2MAX+I=0 ON
WIN • WIN+I=0 ON • MIN/MAX • MIN/MAX+I=0 ON
Measuring ranges 2,5kW: 120W to 2490W
Measuring ranges 10kW: 480W to 9960W
Measuring ranges 2,5kW: 120W to 2490W
Measuring ranges 10kW: 480W to 9960W
ixed 5% or adjustable
ixed 5% or adjustable
0,1s to 50s
0,1s to 50s
0s to 100s
Supply
PowerModule TR3 (12 - 500V AC)
Terminals A1-A2
24-240V AC/DC
Terminals A1-A2
Output
2 CO contact
250V 5A AC
2 CO contact
250V 5A AC
Mechanical
design
45mm
45mm
CE • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
5mm
45mm
Accessories
Page 90
2,5kW and 10kW
Wire link Y1-Y2
Width
103mm
True power consumption 1- or 3-phase Loads
AC Sinus (10 to 400Hz)
0s to 100s
Certiicates
Powermodul
True power consumption 1- or 3-phase Loads
AC Sinus (10 to 400Hz)
Wire link Y1-Y2
Fault latch
Width 45mm
9008662006072
PowerModules TR3 (12 - 500V AC)
w w w. tel e-o n l i n e. co m
Page 91
OVER: Overload monitoring
OVER+I=0 ON: Overlaod monitoring and recognition of disconnected consumers (relay ON or OFF)
UNDER: UNDERload monitoring
UNDER+I=0 ON: UNDERlaod monitoring and recognition of disconnected consumers (relay ON or OFF)
2MIN: Minimum monitoring
2MIN+I=0 ON: Minimum monitoring and recognition of disconnected consumers (relay ON or OFF)
2MAX: Maximum monitoring
2MAX+I=0 ON: Maximum monitoring and recognition of disconnected consumers (relay ON or OFF)
WIN: Monitoring the window between MIN and MAX
WIN+I=0 ON: Monitoring the window between MIN and MAX and recognition of disconnected consumers (relay ON or OFF)
MIN/MAX: Minimum- and Maximum monitoring
MIN/MAX+I=0 ON: Minimum- and maximum monitoring and recognition of disconnected consumers (relay ON or OFF)
Connected 3~ 400V with power module 24V AC without fault latch
IN<12A
Connected 1~ 230V with power module 230V AC without fault latch
but with current transformer. IN>12A
L1
L2
L3
Loadmonitors Series GAMMA
Functions
True power monitoring of 1- or 3-phase loads with adjustable switching thresholds, adjustable start-up suppression time, separately
adjustable tripping delay, selectable fault latch and temperature monitoring of the motor winding.
Connections
True power monitoring for 1- or 3-phase loads
<
Multifunction
<
Temperature monitoring of the motor coil
<
Fault latch; Reset button
<
Recognition of disconnected load I=0
<
Suitable for VFI (10 to 100Hz)
<
Supply voltage selectable via power modules
<
2 CO contact
<
Width 45mm
<
Industrial design
G4BM480V12ATL20
G4BM480V12AFTL20
Art.No. (PQ1)
2394702
2394705
Art.No. (PQ10)
-
-
900866200615
9008662006010
Measured variable
True power consumption 1- or 3-phase Loads
AC Sinus (10 to 400Hz)
True power consumption 1- or 3-phase Loads
AC Sinus (10 to 400Hz)
Measured range PN
0,75kW • 1,5kW • 3kW • 6kW
0,75kW • 1,5kW • 3kW • 6kW
Measuring voltage
1-Phase loads: 0 to 480V AC
3-Phase loads: 3~ 0 to 480/277V
1-Phase loads: 0 to 480V AC
3-Phase loads: 3~ 0 to 480/277V
Measuring rangese 0,75 and 1,5kW: 0 to 6A
Measuring rangese 3 and 6kW: 0 to 12A
Measuring rangese 0,75 and 1,5kW: 0 to 6A
Measuring rangese 3 and 6kW: 0 to 12A
Start • P1 • Delay • Range • Function •
I< • P2 • Reset
Start • P1 • Delay • Range • Function •
I< • P2 • Reset
U/t • Failure P1 • Rel1 • I=0 • Failure P2 • Temp • Rel2
U/t • Failure P1 • Rel1 • I=0 • Failure P2 • Temp • Rel2
2MAX
2MIN
WIN
MIN/MAX
I=0 with optionally selectable relay setting
2MAX
2MIN
WIN
MIN/MAX
I=0 with optionally selectable relay setting
P1: 10% to 120% from PN
P2: 5% to 110% from PN
P1: 10% to 120% from PN
P2: 5% to 110% from PN
ixed, ca. 3% from PN
ixed, ca. 3% from PN
0,1s to 50s
0s to 10s
Type
L1
N
24V~
0V
A1
i
L1
k
A1
L3
L2
15
i
L1
25
15
16
A2
18
T1
L3
15
16 18 26 28
Y1 Y2
k
L2
25
16 18 26 28
T2
25
Y1 Y2
15
26
28
16
A2
18
T1
T2
25
26
28
EAN13-Code
Connected 3~ 400V with power module 400V AC with fault latch
IN<12A
Connections
Connected 3~ 400V with power module 400V AC with fault latch
and current transformer IN>12A
L1
L2
L3
L1
L2
L3
Mesuring ranges Current
Controls
A1
i
L1
k
A1
L3
L2
i
L1
k
Indicators (LEDs)
L3
L2
Functions
15
25
15
16 18 26 28
16 18 26 28
Y1 Y2
15
T1 T2
25
Y1 Y2
15
16
A2
26
28
16
A2
18
25
18
T1
T2
25
26
28
Trigger level P
Hysteresis
Tripping delay
Start-up suppression time
Connected 3~ 400V with power module 400V AC with fault latch
and temperature monitoring sensor IN<12A
Connections
Dimensions
Width 45mm
L1
L2
L3
A1
L1
i
90mm
Powermodul
k
15
5mm
16
18 A2
Supply
PowerModule TR3 (12 - 500V AC)
Terminals A1-A2
PowerModule TR3 (12 - 500V AC)
Terminals A1-A2
Output
2 CO contact
250V 5A AC
2 CO contact
250V 5A AC
Width
Certiicates
Terminal capacity
25
120mm
16 18 26 28
Y1 Y2 15
1s to 10s
Wire link Y1-Y2
Mechanical design
L3
L2
1s to 100s
Wire link Y1-Y2
Fault latch
T1 T2
25
26
28
45mm
Ambient
conditions
Accessories
Page 92
45mm
45mm
CE • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end •
2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 3
(in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms
(in accordance with IEC 60068-2-27)
PowerModules TR3 (12 - 500V AC) • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 93
2MIN
2MAX
WIN
MIN/MAX
Underload monitoring for two independent thresholds
Underload monitoring for two independent thresholds
Monitoring of the threshold level between min and max areas
Underload and overload monitoring for two independent thresholds
I<
Detection of shorted loads with selectable relay setting
Connected 3~ 400V with power module 400V AC with fault latch
IN<12A
Connected 3~ 400V with power module 400V AC with fault latch
and temperature monitoring sensor IN>12A
Reset
True power monitoring of 1- or 3-phase loads
<
Multifunction
<
Fault latch
<
Recognition of disconnected consumers
<
Suitable for VFI (10 to 100Hz)
<
Supply voltage selectable via PowerModules
<
1 CO contact; 2 CO contacts
<
Width 22,5mm or 45mm
<
Industrial design
Connections
G2BM480V12AFL10
G2BM400V12AL10
G2BM400V12AFL10
Art.No. (PQ1)
2390707
2390700
2390702
Art.No. (PQ10)
-
-
-
9008662006119
900866200291
900866200292
True power consumption 1- or 3-phase loads
AC Sinus (10 to 400Hz)
True power consumption of 1- or 3-phase loads
AC Sinus (10 to 400Hz)
True power consumption of 1- or 3-phase loads
AC Sinus (10 to 400Hz)
0,75kW • 1,5kW • 3kW • 6kW
0,5kW • 1kW • 2kW • 4kW
0,5kW • 1kW • 2kW • 4kW
1-phase loads: 0 to 480V AC
3-phase loads: 3~ 0 to 480/277V
1-phase loads: 0 to 415VAC
3-phase loads: 3~ 0 to 415/240V
1-phase loads: 0 to 415VAC
3-phase loads: 3~ 0 to 415/240V
Measuring ranges 0,75 and 1,5kW: 0 to 6A
Measuring ranges 3 and 6kW: 0 to 12A
Measuring ranges 0,5 and 1kW: 0 to 6A
Measuring ranges 2 and 4kW: 0 to 12A
Measuring ranges 0,5 and 1kW: 0 to 6A
Measuring ranges 2 and 4kW: 0 to 12A
Start • Power • Delay • Range • Function
Start • Power • Delay • Range • Function
Start • Power • Delay • Range • Function
U/t • Failure • I=0 • R
U/t • Failure • I=0 • R
U/t • Failure • I=0 • R
OVER + I=0
OVER + I=0
UNDER
UNDER + I=0
OVER
OVER + I=0
UNDER
UNDER + I=0
OVER + I=0
OVER + I=0
UNDER
UNDER + I=0
types
L1
L2
L3
L1
L2
L3
Loadmonitors Series GAMMA
Functions
Reset
A1
i
k
L1
A1
L3
L2
15
i
k
L1
25
15
16 18 26 28
25
16 18 26 28
Y1 Y2
15
T1 T2
25
Y1 Y2 15
16
A2
26
28
16
18
L3
L2
T1 T2
25
26
28
18 A2
EAN13-Code
Measured variable
Connected 3~ 400V with power module 400V AC with fault latch
and current transformer IN<12A
Connected 3~ 400V with power module 24V AC without fault latch
IN>12A
Connections
Measuring ranges PN
Measuring voltage
L1
L2
L3
L1
L2
L3
Measuring range Current
Reset
24V~
0V
A1
i
L1
k
Controls
A1
L3
L2
15
i
L1
15
16
A2
18
T1
k
15
Functions
L3
L2
25
16 18 26 28
Y1 Y2
Indicators (LEDs)
25
Trigger level P
16 18 26 28
T2
25
26
28
Y1 Y2
15
16
A2
18
T1
T2
25
26
28
Hysteresis
Tripping delay
Start-up suppression time
0,1s to 2s
Supply
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
Output
1 CO contact
250V 5A AC
1 CO contact
250V 5A AC
1 CO contact
250V 5A AC
Mechanical
design
90mm
0,1s to 2s
wire link Y1-Y2
22,5mm
22,5mm
22,5mm
CE • GOST
CE • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
•2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
5mm
Page 94
0,1s to 50s
1s to 100s
Width
45mm
0,1s to 2s
wire link Y1-Y2
Certiicates
103mm
5% to 120% of PN
ixed, approx. 3% of PN
0,1s to 2s
Dimensions
Powermodul
5% to 120% of PN
ixed, approx. 3% of PN
wire link Y1-Y2
Fault latch
Width 45mm
5% to 120% from PN
ixed, approx. 3% from PN
Accessories
PowerModules TR2 (12 - 440V AC) and DC power supply SNT2 24VDC • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 95
OVER
UNDER
OVER+I=0
UNDER+I=0
OVER+I=0
Connected 3~ 400V mains with PowerModule 24V AC
without fault latch. IN<12A
L1
L2
L3
Loadmonitors Series GAMMA
Functions
Overload monitoring
Underload monitoring
Overload monitoring with recognition of disconnected consumers
Underload monitoring with recognition of disconnected consumers
Overload monitoring with recognition of disconnected consumers (Rel.ON if I=0)
Connected 1~ 230V mains with PowerModule 230V AC
without fault latch. IN<12A
Measuring transducer
<
True power monitoring of 1- or 3-phase loads
<
Analogue output 4...20mA
<
Suitable for VFI (10 to 100Hz)
<
Zoom voltage 24V to 240V DC and 48V to 240V AC
<
Width 22,5mm
<
Industrial design
Connections
L1
G2BA480V12A 4...20mA
Type
N
24V~
0V
A1
i
k
A1
i
k
L1
L2
L3
L1
L2
L3
15
15
16 18
16 18
Y1 Y2
15
Y1 Y2
15
16
A2
16
A2
18
18
Art.No. (PQ1)
2390705
Art.No. (PQ10)
9008662006119
EAN13-Code
Connected 3~ 400V mains with PowerModule 400V AC
and fault latch. IN<12A
Connected 1~ 230V mains with PowerModule 230V AC
without fault latch. IN>12A
L1
L1
L2
L3
Measured variable
True power consumption 1- or 3-phase loads
AC Sinus (10 to 400Hz)
Measured ranges
0,75kW • 1,5kW • 3kW • 6kW
Measuring voltage
1-Phase loads: 0 to 480V AC
3-Phase loads: 3~ 0 to 480/277V
Connections
Measuring rangese 0,5kW and 1,5kW: 0 to 6A
Measuring rangese 3kW and 6kW: 0 to 12A
Rated current
N
Reset
Zero • Zero Fine • Span • Range
Controls
U • 8 x Analogue Output
Indicators (LEDs)
A1
i
k
A1
i
k
L1
L2
L3
L1
L2
L3
15
15
16 18
16 18
Functions
Signal converter for true power
4 to 20mA (Working resistance max. 500Ω)
Output
Isolation
3kV DC
Setting time
Width 22,5mm
Y1 Y2
15
Y1 Y2
15
16
A2
16
A2
18
18
Width
22,5mm
Certiicates
Dimensions
Mechanical
design
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 96
< 300 ms
24 - 240V DC / 48 - 240V AC
Terminals A1-A2
Supply
Sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 97
Zero
Zero Fine
Span
Range
setting of zero point (0%, 25%, 50%, 75% of nominal value)
fine setting of zero point (0% ... 25% of nominal value)
span (100%, 75%, 50%, 25% of nominal value)
measuring range reversible between 0.6kW, 1.2kW, 2.4kW, 4.8kW
G2BA480V12A 4...20mA in 3-phase mains
L1
L2
L3
N
G2BA480V12A 4...20mA in 3-phase mains with current transformer
<
Effective current measurement
<
Analogue output 4...20mA
<
Suitable for VFI (10 to 100Hz)
<
Zoom voltage 24V to 240V DC and 48V to 240V AC
<
Width 22,5mm
<
Industrial design
G2IA15A 4...20mA
types
A1
i
k
A1
i
k
L1
L2
L3
L1
L2
L3
Load
4...20mA
Measuring transducer
Connections
L1
L2
L3
N
X1 X2 A2
Loadmonitors Serie GAMMA
Functions
X1 X2 A2
Art.No. (PQ1)
2390710
Art.No. (PQ10)
Load
4...20mA
9008662006645
EAN13-Code
Measured variable
Width 22,5mm
Dimensions
Current DC/AC (10 bis 400 Hz)
5A • 10A • 15A
Measured range
Zero • Zero Time • Span • Range
Controls
U • 8 x Analogue output
Indicators (LEDs)
Functions
Signal converter for effective current
4 bis 20mA (Working resistance max. 500Ω)
Output
Isolation
3kV DC
Setting time
< 500 ms
Supply
24-240V DC / 48-240V AC
terminals A1-A2
Width
22,5mm
Certiicates
Mechanical
design
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 98
CE • GOST
Sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 99
Zero
Zero Fine
Span
Range
setting of zero point (0%, 25%, 50%, 75% of nominal value)
fine setting of zero point (0% ... 25% of nominal value)
span (100%, 75%, 50%, 25% of nominal value)
measuring range reversible between 5A, 10A, 15A
G2IA15A 4...20mA in 3-phase mains
G2IA15A 4...20mA in 3-phase mains with current transformer
L
L1
N
N
i
k
Loadmonitors Series GAMMA
Functions
Connections
Power factor monitoring (cosj) in 1- or 3-phase mains
<
Multifunction (G2CM)
<
Underload monitoring (G2CU)
<
Fault latch
<
Recognition of disconnected consumers I=0
<
Suitable for VFI (10 to 100Hz)
<
Supply voltage selectable via PowerModules
<
2 CO contacts (G2CM); 1 CO contact (G2CU)
<
Width 22,5mm
<
Industrial design
types
G2CM400V10AL20
G2CM400V2AL20
G2CU400V10AL10
Art.No. (PQ1)
2390602
2390606
2390600
Art.No. (PQ10)
-
-
-
900866200289
900866200290
900866200288
Power factor (cosj) of
1- or 3-phase loads
AC Sinus (10 to 100Hz)
Power factor (cosj) of
1- or 3-phase loads
AC Sinus (10 to 100Hz)
Power factor (cosj) of
1- or 3-phase loads
AC Sinus (10 to 100Hz)
A1
i
k
A1
X1 X2 A2
X1 X2 A2
Last
4...20mA
Last
4...20mA
EAN13-Code
Measured variable
Width 22,5mm
Dimensions
Measured range
Measuring voltage
Rated current
0,1 to 1
0,1 to 1
1-phase loads: 40 to 240VAC
3-phase loads: 3~ 40/23 to 415/240V
1-phase loads: 40 to 240VAC
3-phase loads: 3~ 40/23 to 415/240V
0,5 to 10A
0,05 to 2A
0,5 to 10A
Start • max • min • Delay • Function
Start • max • min • Delay • Function
Start • min • Delay • Function
U/t • min • max • I=0 • R
U/t • min • max • I=0 • R
U/t • min • I=0 • R
Functions
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
UNDER
UNDER+LATCH
Switching threshold max.
cosj = 0,2 to 1,0
cosj = 0,2 to 1,0
-
Switching threshold min.
cosj = 0,1 to 0,99
cosj = 0,1 to 0,99
cosj = 0,1 to 1,0
-
-
ixed, approx. 3°
(according to 3% bei cosj=0,8)
Controls
Indicators (LEDs)
Hysteresis
Tripping delay
0,1s to 40s
0,1s to 40s
0,1s to 40s
Start-up suppression time
1s to 100s
1s to 100s
1s to 100s
Fault latch
selectable
selectable
selectable
Supply
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
Output
2 CO contacts; 250V, 5A AC
2 CO contacts; 250V, 5A AC
1 CO contact; 250V, 5A AC
Width
Certiicates
Mechanical
design
22,5mm
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 100
0,1 to 1
1-phase loads: 40 to 240VAC
3-phase loads: 3~ 40/23 to 415/240V
PowerModules TR2 (12 - 440V AC) and DC power supply SNT2 24 VDC • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 101
OVER
OVER+LATCH
UNDER
UNDER+LATCH
WIN
WIN+LATCH
Functions
Overload monitoring
Overload monitoring with fault latch
Underload monitoring
Underload monitoring with fault latch
Monitoring the window between Min and Max
Monitoring the window between Min and Max with fault latch
Connected to 3~ 400V mains with
PowerModule 24V AC without
fault latch. IN<10A
Connected to 1~ 230V mains with
PowerModule 230V AC without fault
latch. IN<10A
Connected to 3~ 400V mains with
PowerModule 400V AC and
fault latch. IN<10A
Connected to 3~ 400V mains with
PowerModule 400V AC and
fault latch. IN>10A
Connections
L1
N
24V~
0V
A1 L1k 15
A1 L1k 15
L3 L2 L1i
L3 L2 L1i
15
15
25
A1 L1k 15
L3 L2 L1i
A1 L1k 15
L3 L2 L1i
25
15
25
15
16 18 26 28
16 18 26 28
25
16 18 26 28
16 18 26 28
25
26
28
25
26
28
25
26
28
16
18
A2
16
18
A2
16
18
A2
Width 22,5mm
Page 102
25
26
28
16
18
A2
Dimensions
Page 103
TIME฀RELAYS
TELE offers the widest range of products with the following
performance features:
•
Functionality ranging from simple delayed activation right up
to multifunctional timing relays with a remote potentiometer
connection and potential-free control contact
•
Internal or external power supply (e.g. 24V DC)
•
Various forms of housing for control engineering, industrial
systems and machine building as well as building installations
•
Variants available for DIN rails, switchboard or front installation,
11-pole plug-in base or industrial relays
The robust design with generous terminal space throughout ensures
very good usability and installability.
OVERVIEW
Page
Selection matrix Time relays
Quick and explicit to the right product.
105
Function overview
Explanations of important terms
- A, Bi, Bp, ...
108
Time Relays
- Series Industry: GAMMA
- Series Industry compact: DELTA
- Series plugable: KAPPA, PLUS
- Series Installation: ENYA
- Front installation: FRONT, RONDO
- TimeModule: COMBI
111
121
131
135
147
149
Star-Delta-Relays
- Series Industry: GAMMA
- Series Industry compact: DELTA
- Series plugable: KAPPA
- Series Installation: ENYA
119
129
131
141
Light Controller
- Series Installation: ENYA
143
Emergency light tester
- Series Installation: ENYA
145
w w w. tel e-o n l i n e. co m
Page 105
SERIES
Design
฀Industry฀plug-in
Industry฀compact
ENYA
Installation
COMBI
KAPPA
DELTA
Industry
FRONT
GAMMA
PLUS
TIME฀RELAYS
RONDO
Installation
Functions
Functions
n
Flasher pulse irst
Bi
n
n
n
Flasher pause irst
Bp
n
n
n
ON delay
E
n
n
n
ON and OFF delay with control contact
ER
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
ON delay with control contact
Es
EWs
n
n
n
ON delay and single shot leading edge voltage controlled
EWu
n
n
n
Asymmetric lasher pulse irst
li
n
n
n
n
Asymmetric lasher pause irst
lp
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
ON delay and single shot leading edge with control contact
n
A OFF Delay without Auxiliary Voltage
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Single shot leading edge with control contact
Ws
Single shot leading and trailing edge with control
contact
WsWa
Pulse detection
Wt
Single shot leading edge voltage controlled
Wu
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
E ON delay
n
n
Es ON delay with control contact
n
li Asymmetric lasher pulse irst
n
n
R OFF delay
n
S Star-Delta start-up
Wa Single shot trailing edge with control contact
n
n
n
Ws Single shot leading edge with control contact
n
WsWa Single shot leading and trailing edge with control
contact
n
n
n
n
lp Asymmetric lasher pause irst
n
n
n
n
n
n
n
n
n
n
n
n
EWu ON delay and single shot leading edge voltage controlled
n
n
n
n
n
n
n
n
Bp Flasher pause irst
EWs ON delay and single shot leading edge with control contact
n
Wa
n
Bi Flasher pulse irst
n
n
n
Single shot trailing edge with control contact
n
n
n
n
n
S
n
n
n
ER ON and OFF delay with control contact
n
n
R
n
n
n
n
OFF delay
n
n
n
Star-Delta start-up
n
n
n
TW, 1, 0, P
A
TW, T, 1, 0, P, PN
OFF Delay without Auxiliary Voltage
Wt Pulse detection
n
n
n
n
n
n
n
n
Wu Single shot leading edge voltage controlled
Maintained single shot trailing edge
nWa
n
n
n
nWa Maintained single shot trailing edge
Maintained single shot leading edge
nWu
n
n
n
nWu Maintained single shot leading edge
Maintained single shot leading and single shot trailing
nWuWa
n
n
8
8
8
8
n
n
n
n
n
4
4
8
8
4
4
n
n
n
n
n
7
7
4
8
16
7
7
7
7
7
7
7
n
n
n
n
n
n
n
n
6
digital
8
digital
4
4/4
10/10
4
7/7
10/10
7
7/7
16
Number of remote potentiometer
2
7/7
16
Potential free control contact
1
8/8
2
4/4
2
7/7
1
4/4
1
8/8
Number of remote potentiometer
4/4
n
16
n
4/4
n
7/7
n
Time Ranges
nWuWa Maintained single shot leading and single shot trailing
n
Potential free control contact
n
n
n
8
1
1
1
1
1
1
1
1
1
1
1
Outputs
Outputs
1 CO contact
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
1 CO contact
3 CO contacts
n
1 Thyristor output
n
1 Transistor output
n
1 NO
n
2 NO
n
n
n
n
n
n
n
n
n
n
n
n
2 NO
1O
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
cULus - Certiicates
n
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24 - 240V AC/DC
100 - 240V AC
24V AC/DC
230V AC
230V AC
230V AC
12 - 240V AC/DC
12 - 240V AC/DC
12 - 240V AC/DC
24 - 240V AC/DC
24 - 240V AC/DC
24 - 240V AC/DC
24 - 240V AC/DC
24 - 240V AC/DC
24 - 240V AC/DC
12 - 240V AC/DC
12 - 240V AC/DC
24V AC/DC or 110 - 240V AC
24V AC/DC or 110 - 240V AC
SRW2-PNP 60MIN 24V DC
SRW2-PNP 10MIN 24V DC
SRW2-PNP 1MIN 24V DC
SRW2-PNP 10SEC 24V DC
SRW2-PNP 1SEC 24V DC
SRE2-PNP 60MIN 24V DC
SRE2-PNP 10MIN 24V DC
SRE2-PNP 1MIN 24V DC
SRE2-PNP 10SEC 24V DC
149
SRE2-PNP 3SEC 24V DC
147 147
FSM10 24V AC/DC
E1ZNT 230V AC
E1ZTP 230V AC
E1ZTPNC 230V AC
E3ZS20 12-240V AC/DC
E3ZI20 12-240V AC/DC
E1ZI10 12-240V AC/DC
E1Z1ER10 24-240V AC/DC
E1Z1R10 24-240V AC/DC
E1Z1E10 24-240V AC/DC
E1ZMQ10 24-240V AC/DC
E1ZMW10 24-240V AC/DC
E1ZM10 24-240V AC/DC
E1ZM10 12-240V AC/DC
135 135 135 135 135 137 137 137 139 139 141 143 143 145
COM3TP 24-240V AC/DC
133 133 133
E3ZM20 12-240V AC/DC
K3ZA20 3min 24-240V AC/DC
K3ZS20 12-240V AC/DC
K3ZI20 12-240V AC/DC
K3ZM20P 12-240V AC/DC
131 131 131 131 131
Type
FSM10 100-240V AC
121 121 121 123 123 123 123 125 125 125 125 127 129
K3ZM20 12-240V AC/DC
D6DS 24V AC/DC 110-240V AC
D6DI 24V AC/DC 110-240V AC
D6A 10MIN 24-240V AC/DC
D6A 3MIN 24-240V AC/DC
D6DR 24V AC/DC 230V AC
D6DR 24V AC/DC 110V AC
D6DET 40MIN 12-240V AC/DC
D6DET 4MIN 12-240V AC/DC
D6DE 24V AC/DC 230V AC
D6DE 24V AC/DC 110V AC
D6DQ 24V AC/DC 110-240V AC
D6DM 24V AC/DC 110-240V AC
D6M 12-240V AC/DC
G2ZS20
G2ZS20 24-240V AC/DC
G2ZE10 400V AC
G2ZI20 12-240V AC/DC
G2ZIF20
G2ZIF20 24-240V AC/DC
G2ZA20 10min
G2ZA20 10min 24-240V AC/DC
G2ZM20 12-240V AC/DC
G2ZMF11
G2ZMF11 24-240V AC/DC
Type
111 111 111 113 113 115 115 115 117 119 119
n
Supply voltage
PDI20F 24V AC/DC 110-240V AC
24V AC/DC or 230V AC
24V AC/DC or 110V AC
24V AC/DC or 110 - 240V AC
24V AC/DC or 110 - 240V AC
12 - 240V AC/DC
12 - 440V AC, 24V DC 1)
24 - 240V AC/DC; CoolZoom 2)
400V AC
12 - 240V AC/DC
12 - 440V AC, 24V DC 1)
24 - 240V AC/DC; CoolZoom 2)
24 - 440V AC, 24V DC 1)
24 - 240V AC/DC
12 - 240V AC/DC
12 - 440V AC, 24V DC 1)
24 - 240V AC/DC; CoolZoom 2)
Supply voltage
n
24V AC/DC or 110 - 240V AC
n
PDM11 24V AC/DC 110-240V AC
n
PDM20F 24V AC/DC 110-240V AC
n
24 - 240V AC/DC
n
12 - 240V AC/DC
n
12 - 240V AC/DC
n
12 - 240V AC/DC
n
12 - 240V AC/DC
n
24V AC/DC or 110 - 240V AC
n
24V AC/DC or 110 - 240V AC
n
24 - 240V AC/DC
n
24 - 240V AC/DC
n
24V AC/DC or 230V AC
n
24V AC/DC or 110V AC
n
12 - 60V AC/DC or 60 - 240V AC/DC
n
12 - 60V AC/DC or 60 - 240V AC/DC
n
1 Transistor output
1 NO
n
n
1O
Technical Data Pages
3 CO contacts
n
1 Thyristor output
cULus - Certiicates
2 CO contacts
n
SRE2-PNP 1SEC 24V DC
2 CO contacts
Time Ranges
151 151 151 151 151 151 153 153 153 153 153
Technical Data Pages
1) Power module TR (AC) series and Switching power supply SNT (DC) series; 2) Lower power loss <1W
Page 106
Page 107
A
Bi
Bp
R
S
T
OFF Delay without Auxiliary
Voltage
Flasher pulse irst
Flasher pause irst
OFF delay
Star-Delta start-up
Automatic timer without switch-off
warning
>2s
>2s
<2s
<2s
B1
R
t
U
R
t
U
LED U/t
R
t
t
TW
t
t
t
15s
2t
10s
3t
T
5s
E
ER
Es
TW
Wa
Wi
ON delay
ON and OFF delay with control
contact
ON delay with control contact
Automatic timer with switch-off
warning
Single shot trailing edge with
control contact
Impulse switch with OFF delay
U
LED U/t
S
R
LED U
>2s
>2s
<2s
<2s
B1
U
LED U/t
S
R
U
LED U/t
S
R
EWs
EWu
Ii
Ws
WsWa
Wt
ON delay and single shot leading
edge with control contact
ON delay and single shot leading
edge voltage controlled
Asymmetric lasher pulse irst
Single shot leading edge with
control contact
Single shot leading and trailing
edge with control contact
Pulse detection
U
LED U/t
S
R
U
LED U/t
S
R
t
TW
t
15s
2t
10s
t
5s
3t
T
t
B1
t
R
t
t1
t2
t1 t2
U
LED U/t
S
R
t
<t
t1
<t2 <t2
t
>t2
Ip
P
PN
Wu
nWa
nWuWa
Asymmetric lasher pause irst
Impulse switch mode without time
function
Impulse switch mode power fail
latch
Single shot leading edge voltage
controlled
Maintained single shot trailing
edge
Maintained single shot leading
and trailing edge
Mode
P
U
B1
C1-C2
R
Page 108
R
<2s
>2s
<2s
>2s
>2s
Mode
U
PN
B1
C1-C2
R
<2s
>2s
<2s
>2s
U
U
LED U
LED U/t
>2s
R
t
t
R
t
t
t
t
t
Page 109
Time Relays Series GAMMA
Multifunction Timer
<
Multifunction
<
16 time ranges (G2ZMF11); 7 time ranges (G2ZM20)
<
Time setting by 2 or 3 controls for the selection of range and ine tuning
<
Remote potentiometer optional (G2ZMF11)
<
Supply voltage 12-240V AC/DC (G2ZM20)
<
Supply voltage selectable via PowerModules, DC power supply or by zoom voltage
<
2 CO contacts (G2ZMF11: individual switching by functions with instantaneous contact)
<
Width 22,5mm
<
Industrial design
G2ZMF11 24-240V AC/DC
G2ZMF11
G2ZM20 12-240V AC/DC
Art.No. (PQ1)
120103
120100
120401
Art.No. (PQ10)
-
-
-
900866200026
900866200025
900866200031
Time • 11/20 • Function
Time • 11/20 • Function
Time • Function
U/t • R
U/t • R
U/t • R
E11 • E20
R11 • R20
Es11 • Es20
Wu11 • Wu20
Ws11 • Ws20
Wa11 • Wa20
Bi11 • Bi20
Bp11 • Bp20
E11 • E20
R11 • R20
Es11 • Es20
Wu11 • Wu20
Ws11 • Ws20
Wa11 • Wa20
Bi11 • Bi20
Bp11 • Bp20
E
R
Es
Wu
Ws
Wa
Bi
Bp
selectable
selectable
-
-
-
-
1 • 3 • 10 • 30s
1 • 3 • 10 • 30min
1 • 3 • 10 • 30h
1 • 3 • 10 • 30d
1 • 3 • 10 • 30s
1 • 3 • 10 • 30min
1 • 3 • 10 • 30h
1 • 3 • 10 • 30d
1 • 10s
1 • 10min
1 • 10 • 100h
5% to 100%
5% to 100%
5% to 100%
Control input
terminals Y1-Y2
galvanic separated
terminals Y1-Y2
galvanic separated
terminals A1-B1
loadable
Remote potentiometer
1 (optional); Z1-Y2
1 (optional); Z1-Y2
-
Supply
24 to 240V AC/DC
terminals A1-A2
PowerModulee TR2 or SNT2
terminals A1-A2
12 to 240V AC/DC
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
types
EAN13-Code
Controls
Indicators (LEDs)
Functions
Inst. contact
2-time function
Time ranges
Adjustment range
Width
Certiicates
Mechanical
design
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 110
22,5mm
CE • cULus • GOST
PowerModules TR2 (12 - 440V AC) • DC power supply SNT2 24V DC • Remote potentiomter R2 • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 111
G2ZMF11 and G2ZMF11 24-240V
1 delayed contact (cl. 15-16-18) and 1 inst. contact (cl. 25-26-28)
E11
ON delay
R11
OFF delay with control contact
Es11
ON delay with control contact
Wu11
Single shot leading edge voltage controlled
Ws11
Single shot leading edge with control contact
Wa11
Single shot trailing edge with control contact
Bi11
Flasher pulse irst
Bp11
Flasher pause irst
G2ZM20
E
R
Es
Wu
Ws
Wa
Bi
Bp
ON delay
OFF delay with control input
ON delay with control input
Single shot leading edge voltage controlled
Single shot leading edge with control input
Single shot trailing edge with control input
Flasher pulse first
Flasher pause first
2 delayed contacts
E20
ON delay
R20
OFF delay with control contact
Es20
ON delay with control contact
Wu20
Single shot leading edge voltage controlled
Ws20
Single shot leading edge with control contact
Wa20
Single shot trailing edge with control contact
Bi20
Flasher pulse irst
Bp20
Flasher pause irst
G2ZMF11; G2ZMF11 24-240V
Time Relays Serie GAMMA
Functions
Multifunction Timer
<
Multifunction
<
Off delay without auxiliary voltage
<
Four time ranges
<
Supply voltage can be selected via power module or zoom voltage
<
2 CO contacts
<
Width 22,5mm
<
Industrial design
Connections
G2ZM20
G2ZA20 10min 24-240V AC/DC
G2ZA20 10min
Art.No. (PQ1)
120600
120601
Art.No. (PQ10)
-
-
Time • Function
Time • Function
types
(+)
1
2
U~
U~
R2
S
(-)
(+)
(-)
S
3
A1 Y1
16
15
A1 B1 15
15
Z1 Y2
15
A1 B1
A1
25
15
R
R
A1
25
15
R
R
25
18
26
28
25
26
28
16
18
A2
A2 16 18 26 28
A2 16 18 26 28
25 26 28
16 18 A2
25 26 28
16 18 A2
EAN13-Code
Controls
Width 22,5mm
Dimensions
Indicators (LEDs)
U
U
E • A • nWa • nWu • nWuWa
E • A • nWa • nWu • nWuWa
Inst. contact
-
-
2-time function
-
-
1 • 10s
1 • 10min
1 • 10s
1 • 10min
5% to 100%
5% to 100%
-
-
Functions
Time ranges
Adjustment range
Control input
Remote potentiometer
-
-
Supply
24 to 240V AC/DC
terminals A1-A2
PowerModulee TR2 or SNT2
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
Width
22,5mm
22,5mm
CE • GOST
CE • GOST
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 112
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end •
2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
PowerModules TR2 (12-440V AC) • DC power supply SNT2 24V DC • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 113
E
A
nWa
nWu
nWuWa
On delay
Off delay without auxiliary voltage
Maintained single shot trailing edge
Maintained single shot leading edge
Maintained single shot leading and single shot trailing edge
Time Relays Series GAMMA
Functions
2-Time Multifunction Timer
<
Multifunction
<
10 time ranges (G2ZIF20); 7 time ranges (G2ZI20)
<
Remote potentiometer optional (G2ZIF20)
<
Supply voltage 12-240V AC/DC (G2ZI20)
<
Supply voltage selectable via PowerModules or by zoom voltage
<
2 CO contacts
<
Width 22,5mm
<
Industrial design
Connections
G2ZA20
(+)
U~
G2ZIF20 24-240V AC/DC
G2ZIF20
G2ZI20 12-240V AC/DC
Art.No. (PQ1)
120201
120200
120501
Art.No. (PQ10)
-
-
-
900866200028
900866200027
900866200032
Time1 • Time2 • Function
Time1 • Time2 • Function
Time1 • Time2 • Function
U/t1 • t2 • R
U/t1 • t2 • R
U/t • R
Ip • Ii • ER • EWu • EWs • WsWa • Wt
Ip • Ii • ER • EWu • EWs • WsWa • Wt
Ip • Ii • ER • EWu • EWs • WsWa
types
(-)
A1
A1
15
15
R
25
R
A2 16 18 26 28
25 26 28
16 18 A2
EAN13-Code
Controls
Width 22,5mm
Dimensions
Indicators (LEDs)
Functions
Inst. contact
-
-
-
yes
yes
yes
1 • 3 • 10 • 30s
1 • 3 • 10 • 30min
1 • 10h
1 • 3 • 10 • 30s
1 • 3 • 10 • 30min
1 • 10h
1 • 10s
1 • 10min
1 • 10 • 100h
5% to 100%
5% to 100%
5% to 100%
Control input
terminals Y1-Y2
galvanic separated
terminals Y1-Y2
galvanic separated
terminals A1-B1
loadable
Remote
potentiometer
Time1: terminals Z1-Y2
Time2: terminals Z2-Y2
Time1: terminals Z1-Y2
Time2: terminals Z2-Y2
-
Supply
24 to 240V AC/DC
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
12 to 240V AC/DC
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
Width
22,5mm
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
2-time function
Time ranges
Adjustment range
Certiicates
Mechanical
design
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 114
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
PowerModules TR2 (12 - 440V AC) • DC power supply SNT2 24V DC • Remote potentiometer RONDO R2 • sealable intervention protection
shield FA-G2
w w w. tel e-o n l i n e. co m
Page 115
G2ZIF20
Ip
Ii
ER
EWu
EWs
WsWa
Wt
G2ZI20
Ip
Ii
ER
EWu
EWs
WsWa
Time Relays Series GAMMA
Functions
Asymmetric lasher pause irst
Asymmetric lasher pulse irst
ON delay and OFF delay with control contact
ON delay single shot leading edge voltage controlled
ON delay single shot leading edge with control contact
Single shot leading and single shot trailing edge with control contact
Pulse sequence monitoring
Asymmetric lasher pause irst
Asymmetric lasher pulse irst
ON delay and OFF delay with control contact
ON delay single shot leading edge voltage controlled
ON delay single shot leading edge with control contact
Single shot leading and single shot trailing edge with control contact
G2ZIF20; G2ZIF20 24-240V
(+)
1
S
(-)
2
2
R2
t2
3
3
A1 Y1
15
25
18
26
<
ON delay
<
16 time ranges
<
Supply voltage 400V AC
<
1 CO contact
<
Width 22,5mm
<
Industrial design
G2ZE10 400V AC
types
(+)
(-)
A1 B1
15
A1 B1 15
15
Z1 Y2 Z2
16
U~
U~
1
S
R2
t1
Connections
G2ZI20 12-240VAC/DC
Singlefunction Timer
28
25
26
28
16
18
A2
A1
25
15
R
R
A1
25
15
R
R
A2 16 18 26 28
A2 16 18 26 28
25 26 28
16 18 A2
25 26 28
16 18 A2
Art.No. (PQ1)
120104
Art.No. (PQ10)
9008662005440
EAN13-Code
Controls
Time
U/t • R
Indicators (LEDs)
Width 22,5mm
Dimensions
Functions
E
Inst. contact
-
2-time function
1 • 3 • 10 • 30s
1 • 3 • 10 • 30min
1 • 3 • 10 • 30h
1 • 3 • 10 • 30d
Time ranges
5% to 100%
Adjustment range
Control input
-
Remote potentiometer
-
Supply
400V AC
terminals A1-A2
Output
1 CO contact
250V, 5A AC
Width
22,5mm
Certiicates
Mechanical
design
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 116
CE • cULus • GOST
Sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 117
E
Time Relays Series GAMMA
Functions
ON delay
Star-Delta Timer
<
Star-Delta start-up
<
4 time ranges (star-time)
<
Transit time selectable
<
Supply voltage via PowerModules or DC power supply by zoom voltage 24 to 240V AC/DC
<
2 CO contacts
<
Width 22,5mm
<
Industrial design
Connections
G2ZE10 400VAC
L1
L2
G2ZS20 24-240V AC/DC
G2ZS20
Art.No. (PQ1)
120301
120300
Art.No. (PQ10)
-
-
900866200030
900866200029
Time Y • Time Y à D
Time Y • Time Y à D
U/tY • R
U/tY • R
S
S
types
A1
15
15
16 18
16
18
A2
EAN13-Code
Controls
Width 22,5mm
Dimensions
Indicators (LEDs)
Functions
Inst. contact
-
-
2-time function
-
-
Time Y: 10s • 30s • 1min • 3min
Time Y à D: 40ms • 60ms • 80ms • 100ms
Time Y: 10s • 30s • 1min • 3min
Time Y à D: 40ms • 60ms • 80ms • 100ms
5% to 100% (TimeY)
5% to 100% (TimeY)
-
-
Time ranges
Adjustment range
Control input
-
-
Supply
24 to 240V AC/DC
terminals A1-A2
PowerModule TR2 or SNT2
terminals A1-A2
Output
2 CO contacts
250V, 5A AC
2 CO contacts
250V, 5A AC
Width
Certiicates
Mechanical
design
22,5mm
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 118
22,5mm
CE • cULus • GOST
PowerModules TR2 (12 - 440V AC) • DC power supply SNT2 24VDC • sealable intervention protection shield FA-G2
w w w. tel e-o n l i n e. co m
Page 119
S
Star (15-16-18) - Delta (25-26-28) start-up
Time Relays Series DELTA
Functions
Multifunction Timer
<
Multifunction
<
8 time ranges
<
Supply voltage through zoom voltage 12 to 240V AC/DC (D6M); dualvoltage (D6DM; D6DQ)
<
1 CO contact
<
Width 22,5mm
<
Industrial design
Connections
G2ZS20; G2ZS20 24-240V
D6M 12-240V AC/DC
D6DM
24V AC/DC 110-240V AC
D6DQ
24V AC/DC 110-240V AC
Art.No. (PQ1)
234002
234000
234010
Art.No. (PQ10)
-
-
-
EAN13-Code
900866200130
900866200127
900866200134
Controls
Time • Function
Time • Function
Time • Function
U/t • R
U/t • R
U/t • R
E • R • Ws • Wa • Es • Wu • Bp • Wt
E • R • Ws • Wa • Es • Wu • Bp • Wt
E • R • Wu • Bp
types
A1
15
15
16
Width 22,5mm
25
18 26
28
25
26
28
16
18
A2
Dimensions
Indicators (LEDs)
Functions
Inst. contact
-
-
-
2-time function
-
-
-
1 • 10s
1 • 10min
1 • 10h
1 • 10d
1 • 10s
1 • 10min
1 • 10h
1 • 10d
1 • 10s
1 • 10min
1 • 10h
1 • 10d
Time ranges
Adjustment range
Control input
Remote potentiometer
5% to 100%
5% to 100%
terminals A1-B1
loadable
terminals A1-B1
loadable
-
-
-
Supply
12 to 240V AC/DC
terminals A1-A2
switchable
24V AC/DC or
110 to 240V AC
terminals A1-A2
switchable
24V AC/DC or
110 to 240V AC
terminals A1-A2
Output
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Width
Certiicates
Mechanical
design
22,5mm
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1)
Accessories
Page 120
5% to 100%
terminals A1-B1
loadable
-
w w w. tel e-o n l i n e. co m
Page 121
E
R
Ws
Wa
Es
Wu
Bp
Wt
ON delay
OFF delay with control contact
Single shot leading edge with control contact
Single shot trailing edge with control contact
ON delay with control contact
Single shot leading edge voltage controlled
Flasher pause first
Pulse detection
D6M; D6DM; D6DQ
Time Relays Series DELTA
Functions
Connections
Singlefunction Timer
<
ON delay (D6DE)
<
ON delay two wire connection (D6DET)
<
8 time ranges (D6DE)
<
4 time ranges (D6DET)
<
Dualvoltage
<
1 CO contact (D6DE)
<
1 Thyristor (D6DET)
<
Width 22,5mm
<
Industrial design
types
D6DE 24V AC/DC 110V AC
D6DE 24V AC/DC 230V AC
D6DET 4MIN 12-240V AC/DC
D6DET 40MIN 12-240V AC/DC
Art.No. (PQ1)
234051
234050
234090
234091
Art.No. (PQ10)
-
-
-
-
900866200137
900866200136
900866200145
900866200146
Time
EAN13-Code
Controls
Width 22,5mm
Dimensions
Indicators (LEDs)
Functions
Time
Time
U/t • R
U/t • R
-
E
E
E
E
Inst. contact
-
-
-
-
2-time function
-
-
-
-
1 • 10s
1 • 10min
1 • 10h
1 • 10d
1 • 10s
1 • 10min
1 • 10h
1 • 10d
1 • 4s • 30s
4min
10 • 40s
5 • 40min
5% to 100%
5% to 100%
5% to 100%
5% to 100%
-
-
-
-
-
-
-
-
switchable
24V AC/DC or
110V AC
terminals A1-A2
switchable
24V AC/DC or
230V AC
terminals A1-A2
selectable through wire link
12 to 60V AC/DC or
60 to 240V AC
terminals A1-A2
selectable through wire link
12 to 60V AC/DC or
60 to 240V AC
terminals A1-A2
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
1 Thyristor
250V, 10 to 500mA AC
1 Thyristor
250V, 10 to 500mA AC
Time ranges
Adjustment range
Control input
Remote
potentiometer
Supply
Output
Width
Certiicates
Mechanical
design
22,5mm
22,5mm
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1)
Accessories
Page 122
Time
U/t • R
-
w w w. tel e-o n l i n e. co m
Page 123
E
Time Relays Series DELTA
Functions
ON delay
Singlefunction Timer
<
OFF delay with control contact (D6DR)
<
OFF delay without auxiliary voltage (D6A)
<
8 time ranges (D6DR)
<
4 time ranges (D6A)
<
Dualvoltage (D6DR); zoom voltage (D6A)
<
1 CO contact
<
Width 22,5mm
<
Industrial design
Connections
D6DE
D6DR 24V AC/DC 110V AC
D6DR 24V AC/DC 230V AC
D6A
3MIN 24-240V AC/DC
D6A
10MIN 24-240V AC/DC
Art.No. (PQ1)
234061
234060
234007
234008
Art.No. (PQ10)
-
-
-
-
900866200140
900866200139
9008662005754
9008662005976
types
EAN13-Code
Controls
D6DET 12-60V AC/DC
D6DET 60-240V AC/DC
Connections
Indicators (LEDs)
Functions
Time
U
U
R
R
A
A
-
-
-
-
-
-
-
-
1 • 10s
1 • 10min
1 • 10h
1 • 10d
1 • 10s
1 • 10min
1 • 10h
1 • 10d
1 • 10s
1 • 3min
1 • 10s
1 • 10min
5% to 100%
5% to 100%
10% to 100%
10% to 100%
terminals A1-B1
loadable
terminals A1-B1
loadable
-
-
Control input
Remote potentiometer
Supply
Output
Width
Certiicates
Mechanical
design
-
-
-
-
switchable
24V AC/DC or
110V AC
terminals A1-A2
switchable
24V AC/DC or
230V AC
terminals A1-A2
24-240V AC/DC
terminals A1-A2
24-240V AC/DC
terminals A1-A2
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
22,5mm
22,5mm
22,5mm
22,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1)
Accessories
Page 124
Time
Inst. contact
Adjustment range
Dimensions
Time
U/t • R
2-time function
Time ranges
Width 22,5mm
Time
U/t • R
-
w w w. tel e-o n l i n e. co m
Page 125
R
A
OFF delay with control contact
OFF delay without auxiliary voltage
D6DR
Time Relays Series DELTA
Functions
D6A
2-Time Multifunction Timer
<
Asymmetric lasher
<
2-time function
<
8 time ranges
<
Dualvoltage
<
1 CO contact
<
Width 22,5mm
<
Industrial design
Connections
types
D6DI 24V AC/DC 110-240V AC
Art.No. (PQ1)
234011
Art.No. (PQ10)
Width 22,5mm
Dimensions
-
EAN13-Code
900866200135
Controls
Time1 • Time2
U/t • R
Indicators (LEDs)
Functions
Ip • Ii (with wire link A1-B1)
-
Inst. contact
2-time function
yes
1 • 10s
1 • 10min
1 • 10h
1 • 10d
Time ranges
5% to 100%
Adjustment range
Control input
Remote
potentiometer
Supply
switchable
24V AC/DC or
110 to 240V AC
terminals A1-A2
Output
1 CO contact
250V, 5A AC
Width
22,5mm
Certiicates
Mechanical
design
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1)
Accessories
Page 126
CE • cULus • GOST
-
w w w. tel e-o n l i n e. co m
Page 127
Ip
Ii
Asymmetric flasher pause first
Asymmetric flasher pulse first (with wire link A1-B1)
D6DI
Time Relays Series DELTA
Functions
Star-Delta Timer
<
Star-Delta start-up
<
4 time ranges
<
Dualvoltage
<
2 NO contacts
<
Width 22,5mm
<
Industrial design
Connections
types
D6DS 24V AC/DC 110-240V AC
Art.No. (PQ1)
234070
Art.No. (PQ10)
900866200141
EAN13-Code
Time Y • Time Y à D
Controls
Width 22,5mm
Dimensions
U•R
Indicators (LEDs)
Functions
S
Inst. contact
-
2-time function
Time Y: 10s • 30s • 1min • 3min
Time Y à D: 40ms • 60ms • 80ms • 100ms
Time ranges
5% to 100% (TimeY)
Adjustment range
Control input
-
Supply
switchable
24V AC/DC or
110 to 240V AC
terminals A1-A2
Output
2 NO contacts
250V, 8A AC
Width
22,5mm
Certiicates
Mechanical
design
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1)
Accessories
Page 128
CE • cULus • GOST
-
w w w. tel e-o n l i n e. co m
Page 129
S
Star-Delta start-up
D6DS
Time Relays Series KAPPA
Functions
Connections
Multifunction Timer
<
Multifunction (K3ZM, K3ZA20)
<
2-Time Multifunction Timer (K3ZI20)
<
Start-Delta start-up (K3ZS20)
<
7 time ranges (K3ZM and K3ZI20)
<
4 time ranges (K3ZS20, K3ZA20)
<
Supply voltage through zoom voltage 12 to 240V AC/DC or 24 to 240V AC/DC
<
2 CO contacts
<
Width 38mm
<
Plug-in mounting
K3ZM20
12-240V AC/DC
K3ZM20P
12-240V AC/DC
K3ZI20 12-240V AC/DC
K3ZS20 12-240V AC/DC
K3ZA20 24-240V AC/DC
Art.No. (PQ1)
135100
135200
135101
135300
135400
Art.No. (PQ10)
-
-
-
-
-
EAN13-Code
9008662005914
9008662006492
9008662005921
9008662005938
9008662006133
Controls
Time • Function
Time • Function
Time 1 • Time 2 •
Function
Time Y • Time Y à D
Time • Function
U/t • R
U/t • R
U/t • R
U/t • R
U
E • R • Es • Wa • Es •
Wu • Bp
E • R • Es • Wa • Es •
Wu • Bp
Ip • Ii • ER • EWu • EWs
• WsWa • Wt
S
E • A • nWa • nWu •
nWuWa
-
-
-
-
-
types
Width 22,5mm
Dimensions
Indicators (LEDs)
Functions
Inst. contact
2-time function
-
-
yes
-
-
1 • 10s
1 • 10min
1 • 10h • 100h
1 • 10s
1 • 10min
1 • 10h • 100h
1 • 10s
1 • 10min
1 • 10h • 100h
Time Y: 10s • 30s • 1min
• 3min
Time Y à D: 40ms •
60ms • 80ms • 100ms
1 • 10s
1 • 3min
Adjustment range
5% to 100%
5% to 100%
5% to 100%
5% to 100% (Time Y)
5% to 100%
Control input
pins S2-S5
loadable
pins S5-S6
Not potential free
Potential free control
pins S2-S5
loadable
-
-
-
-
-
Supply
12 to 240V AC/DC
pins S2-S10
12 to 240V AC/DC
pins S2-S10
12 to 240V AC/DC
pins S2-S10
12 to 240V AC/DC
pins S2-S10
24 to 240V AC/DC
pins S2-S10
Output
2 CO
250V, 8A AC
2 CO
250V, 8A AC
2 CO
250V, 8A AC
2 CO
250V, 8A AC
2 CO
250V, 8A AC
Width
38mm
38mm
38mm
38mm
38mm
CE
CE
CE
CE
CE
Time ranges
Remote potentiometer
Certiicates
Mechanical
design
Ambient
conditions
Accessories
Page 130
-
Self-extinguishing plastic housing, IP rating IP40 • Mounted on 11-pole screw terminal socket in accordance with IEC 60067-1-18a •Mounting
position: any
Ambient temperature: -25 to +55°C • Storage temperature: -25 to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to
85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC 60664-1)
Relay socket R11X, PF-113BEIM
w w w. tel e-o n l i n e. co m
Page 131
Time Relays Series PLUS
Functions
K3ZM20
E
ON delay
R
OFF delay with control contact
Ws
Single shot leading edge with control contact
Wa
Single shot trailing edge with control contact
Es
ON delay with control contact
Wu
Single shot leading edge voltage controlled
Bp
Flasher pause first
Ip
Ii
ER
EWu
EWs
WsWa
Wt
Asymmetric flasher pause first
Asymmetric flasher pulse first (with wire link A1-B1)
ON delay and OFF delay with control contact
ON delay single shot leading edge voltage controlled
ON delay single shot leading edge with control contact
Single shot leading and single shot trailing edge with control contact
Pulse sequence monitoring
K3ZA20
K3ZS20
E - ON delay
S
A - Off delay without auxiliary voltage
nWa - Maintained single shot trailing edge
nWu - Maintained single shot leading edge
nWuWa - Maintained single shot leading and single shot trailing edge
K3ZM20
A2
U
K3ZS20
K3ZI20
A1
A2
Star-Delta start-up
A2
A2
U
Multifunction
<
8 to 16 time ranges
<
Remote potentiometer for time setting required (PDM20F; PDI20F)
<
1 CO contact and 1 NO contact (PDM20F)
<
2 CO contacts (PDM11)
<
1 normally closed contact and 1 normally open contact
<
Width 38mm
<
Cap size 45mm
<
Plug-in mounting
PDM20F
24VAC/DC 110-240VAC
PDM11
24VAC/DC 110-240VAC
PDI20F
24VAC/DC 110-240VAC
Art.No. (PQ1)
236003
236100
236011
Art.No. (PQ10)
-
-
-
EAN13-Code
900866200194
900866200201
900866200198
Controls
Time • Function
Time • Function
Time1 • Time2 •
Function
U/t • R
U/t • R
U/t • R
E
R
Ws
Wa
Es
Wu
Bp
Wt
E11 • E20
R11 • R20
Ws11 • Ws20
Wa11 • Wa20
Es11 • Es20
Wu11 • Wu20
Bp11 • Bp20
Wt11 • Wt20
Ip
Ii
ER
EWs
EWu
Inst. contact
-
selectable
-
2-time function
-
-
yes
1 • 10sec
1 • 10min
1 • 10h
1 • 10d
1 • 3 • 10 • 30sec
1 • 3 • 10 • 30min
1 • 3 • 10 • 30h
1 • 3 • 10 • 30d
1 • 10sec
1 • 10min
1 • 10h
1 • 10d
Adjustment range
5% to 100%
5% to 100%
5% to 100%
Control input
pins S2-S5
loadable
pins S2-S5
loadable
pins S2-S5
loadable
Remote potentiometer
pins S6-S8
-
Time1: pins S3-S6
Time2: pins S6-S8
Supply
selectable via pins
24V AC/DC (S2-S7)
110 to 240V AC (S2-S10)
selectable via pins
24V AC/DC (S2-S7)
110 to 240V AC (S2-S10)
selectable via pins
24V AC/DC (S2-S7)
110 to 240V AC (S2-S10)
Output
1 CO contact and
1 NO contact
250V, 8A AC
2 CO contacts
250V, 8A AC
1 CO contact and
1 NO contact
250V, 8A AC
types
S
Connections
K3ZA20
<
Connections
A1
U
S
A1
Multifunction Timer
K3ZI20
A1
Indicators (LEDs)
Functions
U
Time ranges
K3ZM20P
Dimensions
Width 38mm
A2
A1
51
S
45
U
Width
Certiicates
Mechanical
design
20
80
Page 132
Ambient
conditions
47
38
Accessories
38mm
38mm
38mm
CE • GOST
CE • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Connection and mounting by 11-pin socket in accordance with IEC 60067-1-18a •
Mounting position: any
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1)
Relay socket R11X, PF-113BEIM; Remote potentiometer RONDO R2 (1Ω)
w w w. tel e-o n l i n e. co m
Page 133
PDM20; PDM20F; PDM10
E
On delay
R
OFF delay with control contact
Ws
Single shot leading edge with control contact
Wa
Single shot trailing edge with control contact
Es
ON delay with control contact
Wu
Single shot leading edge voltage controlled
Bp
Flasher pause first
Wt
Pulse sequence monitoring
PDI20F
lp
li
ER
EWs
EWu
Asymmetric flasher pause first
Asymmetric flasher pulse first
On delay and off delay with control input
On delay and single shot leading edge with control input
On delay and single shot leading edge
voltage controlled
PDM20F (110-240V~)
PDM20F (24V)
PDM11
1 delayed contact (S1-S3-S4) and 1 instantaneous contact (S8-S9-S11)
E11
ON delay
R11
OFF delay with control contact
Ws11
Single shot leading edge with control contact
Wa11
Single shot trailing edge with control contact
Es11
ON delay with control contact
Wu11
Single shot leading edge voltage controlled
Bp11
Flasher pause first
Wt11
Pulse sequence monitoring
2 delayed contacts
E20
ON delay
R20
OFF delay with control contact
Ws20
Single shot leading edge with control contact
Wa20
Single shot trailing edge with control contact
Es20
ON delay with control contact
Wu20
Single shot leading edge voltage controlled
Bp20
Flasher pause first
Wt20
Pulse sequence monitoring
Time Relays Series ENYA
Functions
Multifunction Timer
<
Multifunction
<
7 time ranges
<
Zoom voltage 12 to 240V AC/DC or 24 to 240V AC/DC
<
1 CO contact (E1Z)
<
2 CO contacts (E3Z)
<
Width 17,5mm and 35mm
<
Installation design
Connections
E3ZM20
12-240V AC/DC
types
PDM11 (110-240V~)
PDI20F (24V)
110100
110200
-
110202
-
110100A
110200A
110206A
110202A
EAN13-Code
900866200019
900866200009
900866200012
900866200521
900866200014
Controls
Time • Function
Time • Function
Time • Function
Time • Function
Time • Function
U/t • R
U/t • R
U/t • R
U/t • R
U/t • R
E • R • Ws • Wa • Es •
Wu • Bp
E • R • Ws • Wa • Es •
Wu • Bp
E • R • Ws • Wa • Es •
Wu • Bp
E • R • Ws • Wa • WsWa
• Wu • Wt
E • R • Wu • Bp
Functions
Inst. contact
-
-
-
-
-
2-time function
-
-
-
-
-
1 • 10s
1 • 10min
1 • 10h • 100h
1 • 10s
1 • 10min
1 • 10h • 100h
1 • 10s
1 • 10min
1 • 10h • 100h
1 • 10s
1 • 10min
1 • 10h • 100h
1 • 10s
1 • 10min
1 • 10h • 100h
Control input
Remote
potentiometer
Supply
5% to 100%
5% to 100%
5% to 100%
5% to 100%
5% to 100%
terminals A1-B1
loadable
Terminals A1-B1
loadable
terminals A1-B1
selectable
terminals A1-B1
loadable
terminals A1-B1
loadable
-
-
-
-
-
12 to 240V AC/DC
terminals A1-A2
12 to 240V AC/DC
terminals A1-A2
24 to 240V AC/DC
terminals A1-A2
24 to 240V AC/DC
terminals A1-A2
24 to 240V AC/DC
terminals A1-A2
Output
2 CO contacts
250V, 8A AC
1 CO contact
250V, 8A AC
1 CO contact
250V, 8A AC
1 CO contact
250V, 8A AC
1 CO contact
250V, 8A AC
Width
35mm
17,5mm
17,5mm
17,5mm
17,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 134
E1ZMQ10
24-240V AC/DC
111100
Adjustment range
Dimensions
E1ZMW10
24-240V AC/DC
Art.No. (PQ1)
Time ranges
Width 38mm
E1ZM10
24-240V AC/DC
Art.No. (PQ10)
Indicators (LEDs)
Connections
E1ZM10
12-240V AC/DC
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
-
w w w. tel e-o n l i n e. co m
Page 135
E
R
Ws
Wa
Es
Wu
Bp
WsWa
Wt
E1ZM
Time Relays Serie ENYA
Functions
ON delay
OFF delay with control input
Single shot leading edge with control input
Single shot trailing edge with control input
ON delay with control input
Single shot leading edge voltage controlled
Flasher pause first
Single shot leading edge and single shot trailing edge with control input
Pulse sequence maintaining
Singlefunction
<
Singlefunction
<
7 time ranges
<
Zoom voltage 24 to 240V AC/DC
<
1 CO contact
<
Width 17,5mm
<
Installation design
Connections
E3ZM20
types
(+)
U~
( -)
E1Z1R10 24-240V AC/DC
E1Z1ER10 24-240V AC/DC
S
A1
15
R
-
-
-
(+)
(+)
U~
U~
( -)
15
A1 B1
( -)
( -)
15
A1 B1
A1
S
15 25
A1 B1
A1
15
R
15
R
25
R
A2 16 18 26 28
A2 16 18
A2 16 18
A2
16 18
A2
16 18
A2
16 18
26 28
15 25
A1 B1
A1
15
R
25
R
A2 16 18 26 28
A2
16 18 26 28
Art.No. (PQ1)
110204A
110205A
110208A
9008662000162
9008662006065
9008662006270
Time
Time
Time
U/t • R
U/t • R
U/t • R
E
R
ER
Inst. contact
-
-
-
2-time function
-
-
ja
Time ranges
1 • 10s
1 • 10min
1 • 10 • 100h
1 • 10s
1 • 10min
1 • 10 • 100h
1 • 10s
1 • 10min
1 • 10 • 100h
Adjustment range
5% to100%
5% to 100%
5% to 100%
-
terminals A1-B1
loadable
terminals A1-B1
loadable
-
-
-
24 to 240V AC/DC
terminals A1-A2
24 to 240V AC/DC
terminals A1-A2
24 to 240V AC/DC
terminals A1-A2
1 CO contact
250V, 8A AC
1 CO contact
250V, 8A AC
1 CO contact
250V, 8A AC
Art.No. (PQ10)
EAN13-Code
Controls
Width 17,5mm
Dimensions
Width 35mm
Indicators (LEDs)
45mm
87mm
87mm
45mm
Functions
Control input
Remote
potentiometer
Supply
5mm
44mm
60mm
17,5mm
5mm
44mm
60mm
35mm
Output
Width
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 136
E1Z1E10 24-240V AC/DC
(+)
U~
17,5mm
17,5mm
17,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end •
2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to +70°C •
relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
-
w w w. tel e-o n l i n e. co m
Page 137
E
R
ER
Time Relays Series ENYA
Functions
ON delay
OFF delay with control input
On delay and off delay with control input
2-Time Multifunction Timer
<
Asymmetric lasher (E1Z)
<
2-time multifunction (E3Z)
<
7 time ranges
<
Zoom voltage 12 to 240 V AC/DC
<
1 CO contact (E1Z); 2 CO contacts (E3Z)
<
Width 17,5mm; 35mm
<
Installation design
Connections
E1Z
(+)
(+)
U~
( -)
E1ZI10 12-240V AC/DC
E3ZI20 12-240V AC/DC
Art.No. (PQ1)
110101
111101
Art.No. (PQ10)
-
-
EAN13-Code
900866200011
900866200020
Controls
Time 1 • Time 2
Time 1 • Time 2 • Function
types
U~
( -)
S
15
A1 B1
A1
15
R
15
A1 B1
A1
15
R
A2 16 18
A2 16 18
A2
16 18
A2
16 18
Dimensions
Width 17,5mm
Indicators (LEDs)
Functions
yes
1 • 10s
1 • 10min
1 • 10h • 100h
1 • 10s
1 • 10min
1 • 10h • 100h
5% to 100%
5% to 100%
-
terminals A1-B1
loadable
-
-
12 to 240V AC/DC
terminals A1-A2
12 to 240V AC/DC
terminals A1-A2
Output
1 CO contact
250V, 8A AC
2 CO contacts
250V, 8A AC
Width
17,5mm
35mm
CE • cULus • GOST
CE • cULus • GOST
87mm
45mm
Adjustment range
Control input
Remote
potentiometer
Supply
60mm
17,5mm
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 138
Ip • Ii • ER • EWu • EWs • WsWa • Wt
-
Time ranges
44mm
U/t • R
Ip • Ii (wire link A1-B1)
yes
Inst. contact
2-time function
5mm
U/t • R
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
-
w w w. tel e-o n l i n e. co m
Page 139
Ip
Ii
ER
EWu
EWs
WsWa
Wt
Asymmetric lasher pause irst
Asymmetric lasher pulse irst
ON delay and OFF delay with control contact
ON delay single shot leading edge voltage controlled
ON delay single shot leading edge with control contact
Single shot leading and single shot trailing edge with control contact
Pulse sequence monitoring
E1ZI10
(+)
(+)
_
U~
(-)
( -)
Star-Delta Timer
<
Star-Delta start-up
<
4 time ranges (star-time)
<
Selectable transit time
<
Zoom voltage 12 to 240V AC/DC
<
2 CO contacts
<
Width 35mm
<
Installation design
Connections
E3ZI20
U~
Time Relays Series ENYA
Functions
E3ZS20 12-240V AC/DC
types
S
15
A1 B1
Ii
A1
A1
B1
Ip
15
R
25
15
A1 B1
A1
15
25
R
A2 16 18
A2
16 18
A1
A2
B1
Ii
16
R
18 26
28
26
28
A2
16
18
Art.No. (PQ1)
111300
Art.No. (PQ10)
900866200021
EAN13-Code
Time • Time Y à D
Controls
Width 17,5mm
Dimensions
Width 35mm
U/t • R
Indicators (LEDs)
Functions
S
Inst. contact
-
2-time function
Time Y: 10s • 30s • 1min • 3min
Time Y à D: 40ms • 60ms • 80ms • 100ms
45mm
87mm
87mm
45mm
Time ranges
5% to 100% (Time Y)
Adjustment range
Control input
-
5mm
44mm
60mm
17,5mm
5mm
44mm
60mm
35mm
Supply
12 to 240V AC/DC
terminals A1-A2
Output
2 CO contacts
250V, 8A AC
Width
35mm
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 140
CE • cULus • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
-
w w w. tel e-o n l i n e. co m
Page 141
S
Time Relays Series ENYA
Functions
Star-Delta start-up
Connections
E3ZS
(+)
_
U~
(-)
Light Controller
<
Electronic staircase lighting timer with switch-off warning
<
Retrigger, time extension and energy saving function programmable
<
Impulse switch mode selectable
<
Low switching noise
<
High switching capacity, 80A peak inrush current
<
Automatic 3/4 - wire detection
<
Push-button glow lamp load up to 100mA
<
Width 17,5mm
<
Installation design
types
E1ZTPNC 230V AC
E1ZTP 230V AC
E1ZWI
110310
25
15
A1
A1
15
25
R1
16
A2
16
18 26
R2
28
A2
Art.No. (PQ1)
110300
110301
18
Art.No. (PQ10)
-
-
-
EAN13-Code
900866200017
900866200018
900866200506
Controls
Time • Function
Function/Time
Time
U•R
U•R
U•R
TW • T • 1 • 0 • P • PN
TW • 1 • 0 • P
Wi
26
28
Dimensions
Width 35mm
Indicators (LEDs)
Functions
Inst. contact
-
-
-
2-time function
-
-
-
12min
12min
6min to 60min
Time ranges
45mm
5mm
44mm
60mm
87mm
Adjustment range
Control input
35mm
Remote potentiometer
0,5 to 12min
6min to 60min
terminal B1 (for pushbutton):
pushbutton B1-N (3-wire circuit)
pushbutton B1-L (4-wire circuit)
glow lamp load max. 100mA parallel to the
pushbuttons
terminal B1 (for pushbutton):
pushbutton B1-N (3-wire circuit)
pushbutton B1-L (4-wire circuit)
glow lamp load max. 100mA parallel to the
pushbuttons
-
-
-
Supply
230V AC
terminals L-N
230V AC
terminals L-N
230V AC
terminals L-N
Output
1 NO contact (terminals L-18)
250V, 16A AC
1 NO contact (terminals L-18)
250V, 16A AC
1 NO contact (terminals L-18)
250V, 16A AC
Width
17,5mm
17,5mm
17,5mm
CE • cULus • GOST
CE • cULus • GOST
CE • cULus • GOST
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 142
0,5 to 12min
terminal B1 (for pushbutton):
pushbutton B1-N (3-wire circuit)
pushbutton B1-L (4-wire circuit)
glow lamp load max. 100mA parallel to the
pushbuttons
•
terminals C1-C2
(additional Control input):
voltage range 8..230V AC/DC
galvanic separated
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
-
w w w. tel e-o n l i n e. co m
Page 143
Electronic staircase lighting timer with switch-off warning. The control input allows the connection of pushbuttons with a total glow lamp
load up to 100mA and enables the application in 3- or 4-wire circuits. The unit can be retriggered via the connected pushbuttons. A long
keypress will switch off the light (energy saving function). A fast sequence of pushes (pumping) will extend the period to a multiple of the
selected value. Depending upon distinct type, the following operating methods can be selected by the controls on the unit:
Time Relays Series ENYA
Functions
Emergency light tester
TW Automatic timer with switch-off warning
<
Timer for automatic test of emergency light batteries
T
Automatic timer without switch-off warning
<
Intergrated test button
1
Steady light (ON)
0
Switch-off
<
1 CO contact
P
Impulse switch mode without time function (only types with option P)
<
Width 17,5mm
<
Installation design
PN Impulse switch mode power fail latch (only types with option PN)
Wi Impulse switch mode with off delay
For additional functions of control input (E1ZTPNC) refer to datasheet.
E1ZT (3-wire circuit)
E1ZT (4-wire circuit with attic illumination)
+ 8-230V
AC/DC
18 L
C1 C2
L
B1
N
B1
N
E1ZNT 230V AC
types
18 L
C1 C2
18
Connections
+ 8-230V
AC/DC
L
N
18
L
B1
N
B1
N
Art.No. (PQ1)
110500
Art.No. (PQ10)
L
N
900866200586
EAN13-Code
Time • Test
Controls
E1ZWI 3-wire-circuit
E1ZWI 4-wire-circuit with attic illumination
Connections
U/t • R
Indicators (LEDs)
Functions
18
10min • 30min • 60min • 90min • 2h • 3h switchable
Time ranges
L
18
18
Ws
L
Control input
Supply
230V AC
terminals L-N
-
L
Output
1 CO contact
250V, NC 16A AC; NO 5A AC
L
18
Width
B1
B1
N
N
L
N
B1
N
B1
N
Mechanical
design
Terminal capacity
Ambient
conditions
L
N
Accessories
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1)
-
87mm
45mm
44mm
60mm
Page 144
CE • GOST
Dimensions
Width 17,5mm
5mm
17,5mm
Certiicates
17,5mm
w w w. tel e-o n l i n e. co m
Page 145
Ws
Time Relays Series FRONT
Functions
Emergency light tester
Multifunction Timer
Single shot leading edge with control contact
Ws
U
LED U/t
Testkey
R
t
>2s
Direct connection of emergency lights (I < 16A)
Switching emergency lights with contactor (I > 16A)
L
L
N
N
PE
PE
8 Functions
<
Digital time setting from 0,001s to 999,9h
<
Supply voltage 24V AC/DC or 100-240V AC
<
1 CO contact
<
Width 48mm
<
Front panel mounting (aperture 45mm x 45mm)
Connections
FSM10 24V AC/DC
FSM10 100-240V AC
Art.No. (PQ1)
180600
180601
Art.No. (PQ10)
-
-
9008662
9008662
buttons for programming
buttons for programming
types
L
16
16
<
L
L
L
Notlichter mit eigener
Akkuversorgung
16 18
Notlichter mit eigener
Akkuversorgung
16 18
18
18
N
N
EAN13-Code
Controls
Dimensions
Width 17,5mm
Indicators (LEDs)
Functions
-
-
-
-
digital adjustment
digital adjustment
87mm
45mm
0,001 to 999,9h
0,001 to 999,9h
signal input pin 3-6
stop input pin 3-5
reset input pin 3-7
keylock input pin 3-4
signal input pin 3-6
stop input pin 3-5
reset input pin 3-7
keylock input pin 3-4
-
-
Supply
24V AC/DC
pins 2-10
100 to 240V AC
pins 2-10
Output
1 CO contact
250V, 5A AC
1 CO contact
250V, 5A AC
Control input
Remote potentiometer
60mm
17,5mm
Width
Certiicates
Mechanical
design
Ambient
conditions
Accessories
Page 146
functions refer to datasheet
Inst. contact
Adjustment range
44mm
Display
functions refer to datasheet
2-time function
Time ranges
5mm
Display
48mm
48mm
CE • UR • cUR • GOST
CE • UR • cUR • GOST
Self-extinguishing plastic housing, IP rating IP66 • Mounted in front panel aperture 45mm x 45mm by means of retaining clip (included) in
accordance with DIN 43700 • Mounting position any
Ambient temperature: -10 to +55°C • Storage temperature: -10 to +70°C • Transport temperature: -10 to +70°C • relative humidity: 15% to 85%
(in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC 60664-1)
AZ511, R11X
w w w. tel e-o n l i n e. co m
Page 147
A
A2
B
C
D
E
F
G
ON delay
ON delay with power failure detection
ON delay with control contact
OFF delay with control contact
Single shot leading edge with control contact
ON delay pulse operated
Flasher pause first
ON delay with control contact, adding, power failure
Time Relays Series COMBI
Functions
Multifunction Timing Module
<
Timing modul for industrial relays
<
8 Functions
<
8 time ranges
<
Supply voltage through zoom voltage 24-240V AC/DC (must match to used relay)
<
Solid state output to control the connected industrial relay
<
Width 35mm
<
Combination only with industrial relays Series RT and socket types ES9 or PF-113BE/M
Connections
FSM10
types
Reset
Signal
Stop
Lock
6
5
NC
7
4
8
3
9
2
COM3TP 24-240V AC/DC
NO
10
COM
1 11
Art.No. (PQ1)
(-) Supply voltage (+)
237010
Art.No. (PQ10)
Dimensions
Width 48mm
-
EAN13-Code
900866200202
Controls
Time • Function
Indicators (LEDs)
U/t
Functions
70,1
5,5
48
1 • 10s
1 • 10min
1 • 10h
1 • 10d
5% to 100%
Adjustment range
44,5
O
RESET
Inst. contact
2-time function
Time ranges
55,6
DP.
48
E • R • Ws • Wa • Wu • Es • Bp • Bi
S
Control input
terminals A1-B1
loadable
UP
LOCK
Remote potentiometer
-
DOWN
7,5
Supply
24 to 240V AC/DC
terminals A1-A2
Output
2 or 3 CO contacts, Industrial relays
Width
CE • GOST
Mechanical
design
Self-extinguishing plastic housing, IP rating IP40 • Connection and mounting by 11-pin socket in accordance with IEC 60067-1-18a (types ES9
or PF-113BE/M) • Mounting position any
Ambient
conditions
Accessories
Page 148
35mm
Certiicates
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3
(in accordance with IEC 60664-1)
Socket ES9 and PF-113BE/M; industrial relays RT
w w w. tel e-o n l i n e. co m
Page 149
E
R
Ws
Wa
Wu
Es
Bp
Bi
ON delay
OFF delay with control contact
Single shot leading edge with control contact
Single shot trailing edge with control contact
Single shot leading edge voltage controlled
ON delay with control contact
Flasher pause first
Flasher pulse first
COM3T + RTx.x.xxx + PF-113BE/M
Time Relays Series RONDO
Functions
Timer with solid state output
<
ON delay
<
1 time range
<
Transistor output
<
Diameter 28mm
<
Front panel mounting
Connections
SRE2-PNP 1SEC
24V DC
SRE2-PNP 3SEC
24V DC
SRE2-PNP 10SEC
24V DC
SRE2-PNP 1MIN
24V DC
SRE2-PNP 10MIN
24V DC
SRE2-PNP 60MIN
24V DC
Art.No. (PQ1)
237060
237066
237061
237062
237063
237064
Art.No. (PQ10)
-
-
-
-
-
-
900866200208
900866200213
900866200209
900866200210
900866200211
900866200212
types
EAN13-Code
Width 35mm
Dimensions
Controls
Time
Time
Time
Time
Time
Time
Indicators (LEDs)
U•R
U•R
U•R
U•R
U•R
U•R
E
E
E
E
E
E
Functions
Inst. contact
-
-
-
-
-
-
2-time function
-
-
-
-
-
-
1s
3s
10s
1min
10min
60min
Time ranges
10% to 100%
10% to 100%
10% to 100%
10% to 100%
10% to 100%
10% to 100%
Control input
-
-
-
-
-
-
Remote potentiometer
-
-
-
-
-
-
Adjustment range
Supply
24V DC
terminals 2-3
Output
1 transistor
6W (200mA / 30V)
integrated overcurrent protection
Width
diameter 28mm
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 150
CE • GOST
Self-extinguishing plastic housing, IP rating IP64 (frontside) • Mounted in front panel aperture clear diameter 22.5mm by means of retaining
clip (included) in accordance with DIN 43700 • Mounting position any • Shockproof terminal connection according to VBG 4, Schutzart IP10 •
Tightening torque max 1Nm
1 x 0,5 to 1mm² with/without multicore cable end
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +65°C • Transport temperature: -25 to
+65°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 3 (in accordance with IEC 60664-1)
-
w w w. tel e-o n l i n e. co m
Page 151
E
Time Relays Series RONDO
Functions
ON delay
Timer with solid state output
<
Single shot leading edge voltage controlled
<
1 Time range
<
Transistor output
<
Front panel mounting
<
Diameter 28mm
types
SRW2-PNP 1SEC
24V DC
SRW2-PNP 10SEC
24V DC
SRW2-PNP 1MIN
24V DC
SRW2-PNP 10MIN
24V DC
SRW2-PNP 60MIN
24V DC
Art.No. (PQ1)
237080
237081
237082
237083
237084
Art.No. (PQ10)
-
-
-
-
-
900866200217
900866200218
900866200219
900866200220
900866200221
Connections
EAN13-Code
Connections
Controls
Time
Time
Time
Time
Time
Indicators (LEDs)
U•R
U•R
U•R
U•R
U•R
Wu
Wu
Wu
Wu
Wu
Functions
Inst. contact
-
-
-
-
-
2-time function
-
-
-
-
-
1s
10s
1min
10min
60min
10% to 100%
10% to 100%
10% to 100%
10% to 100%
10% to 100%
-
-
-
-
-
Time ranges
Adjustment range
input
output
Control input
Remote potentiometer
PLC
ground
-
-
-
-
-
Supply
24V DC
terminals 2-3
24V DC
terminals 2-3
24V DC
terminals 2-3
24V DC
terminals 2-3
24V DC
terminals 2-3
Output
1 transistor
6W (200mA / 30V)
integrated overcurrent
protection
1 transistor
6W (200mA / 30V)
integrated overcurrent
protection
1 transistor
6W (200mA / 30V)
integrated overcurrent
protection
1 transistor
6W (200mA / 30V)
integrated overcurrent
protection
1 transistor
6W (200mA / 30V)
integrated overcurrent
protection
Width
diameter 28mm
diameter 28mm
diameter 28mm
diameter 28mm
diameter 28mm
CE • GOST
CE • GOST
CE • GOST
CE • GOST
CE • GOST
Certiicates
diameter 28mm
Dimensions
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 152
Self-extinguishing plastic housing, IP rating IP64 (frontside) • Mounted in front panel aperture clear diameter 22.5mm by
means of retaining clip (included) in accordance with DIN 43700 • Mounting position any • Shockproof terminal connection according to VBG 4,
Schutzart IP10 • Tightening torque max 1Nm
1 x 0,5 to 1mm² with/without multicore cable end
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +65°C • Transport temperature: -25 to
+65°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 3 (in accordance with IEC 60664-1)
-
w w w. tel e-o n l i n e. co m
Page 153
Wu
Single shot leading edge voltage controlled
Functions
Connections
Connections
input
output
PLC
ground
diameter 28mm
Page 154
Dimensions
Page 155
MONITORING
SYSTEMS
OVERVIEW
Page
Monitoring Systems
WatchDog pro is a modular, industry-compliant monitoring
system that combines classical monitoring and time-related
functions with the communication potential of ieldbuses,
SMS and e-mail. The central control unit makes the system
intelligent, so that sophisticated monitoring and automation
functions can also be implemented. WatchDog pro combines
the lexibility of SPC with a robust monitoring system for
industrial applications.
Introduction
Selection Matrix
Modules
158
162
163
Energy management
ECO III
The consumption of energy as uniformly as possible
throughout the day offers the supplier the prospect of
considerable savings. Agreeing a peak load rate also
gives the end consumer the opportunity to signiicantly
reduce his energy costs.
201
Sequence controller
STEP-T8
Periodic ilter cleaning with compressed air, simple water
treatment plants, feeding systems, lighting controls, up to
9 output channels are controlled in a timed sequence. No
special programming knowledge is required to put the
device into operation.
203
As a compact unit the pumpcontroller allot the feed
of 2 pumps by alternating operation. According to
requirments two different modes of parallel operation
might be activated to cover high loads. Uniform load
sharing and periodical operation of both pump sets are
the best condition for operational readiness.
205
Pumpalternator
w w w. tel e-o n l i n e. co m
Page 157
MORE฀THAN฀
THE฀SUM฀OF฀
INDIVIDUAL
SENSOR฀RELAYS
Page 158
and rated surge voltage it can perform
WatchDog pro is a modular, industryWatchDog pro is a modular, industry-compliant monitoring
under the harshest industrial conditions.
compliant monitoring system that
system that combines classical monitoring and time-related
Its modular design will bring end-tocombines classical monitoring and timefunctions with the communication potential of ieldbuses, SMS
end advantages from planning through
related functions with the communication
and e-mail. The central control unit makes the system intelligent,
power-on to plant expansion.
potential of ieldbuses, SMS and e-mail.
so that sophisticated monitoring and automation functions can
WatchDog pro
is thus above the
The central control unit makes the
also be implemented. As the problem solver for stationary and
equipment class to which classical
system intelligent, so that sophisticated
mobile applications in the mechanical engineering ield as well
time and monitoring relays belong.
monitoring and automation functions
as for industrial and building systems, WatchDog pro combines
The monitoring functions for current,
can also be implemented. As the
the lexibility of PLC with a robust monitoring system for industrial
voltage, phase sequence, phase failure,
problem solver for stationary and
applications. Thanks to its withstand voltage, clearances,
active power and temperature have
mobile applications in the mechanical
creepage distances and rated surge voltage it can perform under
been combined into an integrated,
engineering ield as well as for industrial
the harshest industrial conditions. Its modular design will bring
modular monitoring scheme with
and building systems, WatchDog pro
end-to-end advantages from planning through power-on to plant
a
system
application
in
mind.
combines the lexibility of PLC with a
expansion.
By combining all necessary monitoring
robust monitoring system for industrial
WatchDog pro is thus above the equipment class to which classical
and control functions it meets the
applications. Thanks to its withstand
time and monitoring relays belong. The monitoring functions for
requirements placed on an automation
voltage, clearances, creepage distances
current, voltage, phase sequence, phase failure, active power
system.
power distribution as well as heating,
An integral component of the central
air conditioning. The system’s modular design and industry
and temperature have been combined into an integrated,
ventilation and air conditioning. The
control unit is the datalogger. Supported
compliance make it perfectly suitable for monitoring small and
modular monitoring scheme with a system application in mind.
system’s modular design and industry
by WatchDog pro, plant and system
medium-sized machines and plant as well as for use in the
By combining all necessary monitoring and control functions it
compliance make it perfectly suitable
data can be logged on a memory card
process industry.
meets the requirements placed on an automation system.
for monitoring small and medium-sized
and used for high-speed evaluating.
An integral component of the central control unit is the
machines and plant as well as for use in
Forming another part of an eficient
datalogger. Supported by WatchDog pro, plant and system
the process industry.
maintenance management system, the
data can be logged on a memory card and used for highinterfaces (ieldbuses, web server, SMS)
speed evaluating. Forming another part of an eficient
will allow simple remote maintenance
maintenance management system, the interfaces (ieldbuses,
as well as integration into a more
web server, SMS) will allow simple remote maintenance as
comprehensive process control system.
well as integration into a more comprehensive process control
WatchDog pro is a quantum leap in the
system.
ield of monitoring technology, building
WatchDog pro is a quantum leap in the ield of monitoring
on the long-established TELE products
technology, building on the long-established TELE products
of the GAMMA industrial series. Typical
of the GAMMA industrial series. Typical applications are
applications are to be found in the areas
to be found in the areas of water supply and waste water
of water supply and waste water disposal,
disposal, power distribution as well as heating, ventilation and
Page 159
COMMUNICATION
WatchDog pro’s parameters are set using a clearly
arranged software interface. Plant documentation can
be produced at the press of a button from the annotated
function list. Communication takes place via a serial
interface or over the net using a web server (LAN or
WAN).
Fieldbus (Modbus RTU)
RS232
Remote Bus
WDP Com
Ethernet
SMS
MMC Card
Page 160
Page 161
OVERVIEW
WatchDog฀pro
Module
Measuring modules
Measured variable
Voltage
Measured range
Type
60mV; 150mV; 10V AC/DC (16,6 - 400Hz)
G2UI1 10V
163
30V; 60V; 300V AC/DC (16,6 - 400Hz)
G2UI1 300V
165
230/400V AC (48 - 63Hz) Phase sequence, asymmetry
G2PI1 400V
167
277/480V AC (48 - 63Hz) Phase sequence, asymmetry
G2PI1 480V
167
60mV AC/DC (Shunt measurement)
G2YI3 60mV
169
20mA; 1A; 5A AC/DC (16,6 - 400Hz)
G2II1 5A
171
100mA; 1A; 10A AC/DC (16,6 - 400Hz)
G2II1 10A
171
5A AC (48 - 63Hz) (Common)
G2JI1 5A
173
1A AC (48 - 63Hz) (Common)
G2JI1 1A
173
True power
600W; 1200W; 2400W; 4800W (max. 12A)
G2BI1 400V12A
175
True-, apparent-, reactive power; power factor
1200W; 4800W (max. 12A)
G2CI1 400V12A
177
PT100 / PT1000 Sensors (4-fold)
-100 to +300°C / -200 to +850°C
G2TI4 PT
179
1-phase
3-phase
Current
1-phase
3-phase
Power
Page
In-/ Outputs
Module
Number
Type
Type
Digital input module
4-point
24V AC/DC (48 - 63Hz)
G2DI4 24V
181
230V AC (48 - 63Hz)
G2DI4 230V
181
potential free inputs, NPN sensors
G2DI4 SC
181
PTC
G2DI4 PTCK
183
Digital output module
Page
8-point
24V DC
G2DI8 24V
185
4-point
isolated relay contacts 250V AC
G2DO4 R
187
isolated PNP semiconductor outputs 24V DC
G2DO4 SP24VDC
187
isolated NPN semiconductor outputs 24V DC
G2DO4 SN24VDC
187
8-point
PNP semiconductor outputs 24VDC
G2DO8 SPC24VDC
189
4 Inputs / 1 Output
0 - 10V; 4 - 20mA standard signals
G2AM4 M
191
Central Unit with MMC Slot and GSM Modem driver
G4WDCU MMC
163
Fieldbus module
Communication between the Central Unit and the process level via Modbus-RTU,
Proibus-DP, DeviceNet, CANopen, Modbus-TCP, EtherNet/IP
G2FBC
193
Fieldbus gateway
Communication between WatchDog pro modules and the process level via Modbus-RTU,
Proibus-DP, DeviceNet, CANopen, Modbus-TCP, EtherNet/IP
G2WDGW2
195
Remote bus coupler
Distributed system enlargement
G2RBC
197
GSM-module
GSM Communications modules
WDP GSM DataCenter
164
GPRS-module
GPRS Communications modules
WDP GPRS DataCenter
164
Central Unit
CPU
Communication
Accessories
Touchpanels
Display size from 3,4 to 10,4 Inch
AGP..., HSD..., GP...
199
MultiMediaCardTM
(MMC)
Formated MulitMediaCardTM for the datalogger function with 1 to 2GB memory
MMC
164
MMC read out package including Datalogger software and MulitMediaCard Reader
MMC-Reader
164
Parameterisation software on CD, running on Windows 98 / ME / 2000 / XP / Vista
WDP Soft
164
Communication equipment: USB serial converter and interface cable RS232
WDP COM
164
Page
Seite 162
WatchDog pro
Central Unit
<
Information about the operating status (error, operation mode, status of
In- and outputs, communication and datalogger)
<
Selectable operation mode
<
Recording of facility- and system data via MultiMediaCardTM (MMCTM)
<
Reinforced insulation of the input and output circuit
<
4 digital inputs
<
2 relay outputs
<
Width 45mm
<
Industrial design
Type
G4WDCU MMC
Art.No. (PQ1)
2500000
Art.No. (PQ10)
-
EAN13-Code
900866200329
Input circuit
Digital inputs
Voltage AC/DC
AC Sinus (48 to 63Hz)
24 to 230V AC • 24 to 100V DC (input activ)
Internal values
Device temperature • Current remote bus • Current local interface •
Supply voltage • Battery voltage
RRun • RStop • Run • Stop
Controls
Indicators (LEDs)
U • UERR • Temp • IRB/LI • Err • Remote • RUN • STOP • Modem • DI1 • DI2 • DI3 • DI4 • R1 • R2 • ready • busy • RS232 • HCom • Com
Datalogger
MMC
Standard bus (RS485)
Businterface
RS232 with PC • Modem
Communication
RS485 over RB
Remote bus
Overvoltage cat.
Rated surge voltage
6kV
max. 845
Registers
Permanent registers
, (RB+), RBA, RBB
III (in accordance with IEC 60664-1)
27 and 128 permanent boolean registers
Supply
24VDC
Output
2 NO contacts
250V AC, 3A AC
Width
45mm
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
CE • GOST
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
WDP SOFT • WDP COM • WDP GSM • MMC Card
w w w. tel e-o n l i n e. co m
Page 163
The user-deined program is stored and executed in the central unit (CU).
The LED’s provide information about the current operation status (error, mode of operation, status of in-/outputs, communication and datalogger) of the system. Facility- and system data are saved event-triggerd on the MultiMediaCardTM (MMCTM) by the usage of the datalogger.
The operation mode can be chosen by the use of the mode selector with following settings:
RRun
RStop
Run
Remote Run (program runs after reset, access of the programming environment to the Central unit is possible)
Remote Stop (program doesn‘t run after reset, access of the programming environment to the Central unit is possible)
Program runs after reset, access of the programming environment to the Central unit is only possible to a limited degree,
communication with modem
Program doesn‘t run after reset, access of the programming environment to the CU is only possible to a limited degree
Stop
WatchDog pro
Functions
The irmware and applications can be updated via the software. The irmware and application update can also be performed by means of
the MultiMediaCardTM.
Connections
Voltage monitoring in 1-phase mains
<
Voltage measurement in 1-phase mains
<
Measured range 10V for standard signal (G2UI1 10V)
<
Measuring ranges for 30V, 60V and 300V (G2UI1 300V)
<
Measuring ranges 60mV and 150mV for shunt measurement (G2UI1 10V)
<
Reinforced insulation of the measuring circuit
<
Measured value transmitting via standard bus
<
Modular monitoring system
<
Width 22,5mm
<
Industrial design
Digital inputs:
DIGND +24V ... 100V DC / 24 ... 230V AC
G2UI1 10V
G2UI1 300V
Art.No. (PQ1)
2500050
2500051
Art.No. (PQ10)
-
-
900866200523
900866200488
Measured variable
Voltage AC/DC
DC or AC Sinus (16,6 to 400Hz)
Voltage AC/DC
DC or AC Sinus (16,6 to 400Hz)
Measured ranges
60mV AC/DC; terminals E-F1(+)
150mV AC/DC; terminals E-F2(+)
10V AC/DC; terminals E-F3(+)
30V AC/DC; terminals E-F1(+)
60V AC/DC; terminals E-F2(+)
300V AC/DC; terminals E-F3(+)
Address adjustment:
Address range 1 to 99
Address adjustment:
Address range 1 to 99
Type
Optional serial interface:
PC: GND RXD TXD
DI
Supply:
DI3
DI4
DI1
DI2 SG STX SRX
RB
RB+ RBA RBB
GND
13
24V
23
14
24
GND
24V DC
remote bus: GND
A
B
EAN13-Code
Dimensions
Width 45mm
Controls
Indicators (LEDs)
Businterface
Overvoltage cat.
Rated surge voltage
Supply
7
45
2600000
WDP SOFT
Parameterisation software
Programming environment on CD, running on Windows 98/ME/2000/XP
2500030
MMC-READER
MMC read out package
including Datenlogger software and MMC Card Reader
2500035
WDP COM
Communication equipment WatchDog pro
including USB serial converter and interface cable RS232
2500040
WDP GSM Datacenter
WatchDog pro GSM Datensolotion for the two-way communication
2500046
WDP GPRS Datacenter
WatchDog pro GPRS Datensolotion for the two-way communication
2500048
WDP GSM
WatchDog pro GSM Package for the simple report of informations via SMS
2500045
MMC 1GB
MultiMediaCard 1GB (formated memorycard)
2500010
MMC 2GB
MultiMediaCard 2GB (formated memorycard)
2500020
STANDARD CABLE HMI/WDP RS485 5M RS485 Standard connecting cable WDP/Touchpanel, display type LCD/STN/TFT
Page 164
III (in accordance with IEC 60664-1)
6kV
6kV
24V DC from local interface
24V DC from local interface
-
-
22,5mm
22,5mm
CE • GOST
CE • GOST
Terminal capacity
Power supply, 230VAC, 24VDC/2,5A, 1-phase
III (in accordance with IEC 60664-1)
Width
Mechanical
Design
G4NG230V24V2.5A
U • Err • Com
Standard bus (RS485)
Output
Certiicates
Accessories
U • Err • Com
Standard bus (RS485)
Ambient
conditions
Accessories
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
2500894
w w w. tel e-o n l i n e. co m
Page 165
Measured ranges 60mV AC/DC
WatchDog pro
Functions
WatchDog pro module for voltage measurement in 1-phase mains.
Measured ranges 150mV AC/DC
Connections
Measured ranges 10V AC/DC
Voltage monitoring in 3-phase mains
<
Voltage measurement in 3-phase mains for 3- and 4-wire circuit
<
Connection of neutral conductor optional
<
Monitoring of phase sequence and phase failure
<
Monitoring of asymmetry
<
Reinforced insulation of the measuring circuit
<
Measured value transmitting via standard bus
<
Modular monitoring system
<
Width 22,5mm
<
Industrial design
G2UI1 10V
Umax = 60mV AC/DC
G2PI1 400V
G2PI480V
Art.No. (PQ1)
2500350
2500360
Art.No. (PQ10)
-
-
900866200490
-
Type
Umax = 10V AC/DC
Umax = 150mV AC/DC
max.
20A
E
E
F1 F2 F3
F1 F2
E
F3
F1 F2 F3
EAN13-Code
Measured ranges 30V AC/DC
Measured ranges 60V AC/DC
Connections
Measured ranges 300V AC/DC
Measured variable
Voltage AC Sinus (48 to 63Hz)
Voltage AC Sinus (48 to 63Hz)
Measured ranges
Phase voltages (U1, U2, U3): 0 to 300V
Average phase-phase voltage (UAVG): 0 to 520V
Asymmetry: 0% to 100%
Phase sequence: 1 (clockwise rotation) • 0 (counter clockwise
rotation)
Phase voltages (U1, U2, U3): 0 to 360V
Average phase-phase voltage (UAVG): 0 to 624V
Asymmetry: 0% to 100%
Phase sequence: 1 (clockwise rotation) • 0 (counter clockwise
rotation)
Address adjustment:
Address range 1 to 99
Address adjustment:
Address range 1 to 99
G2UI1 300V
Umax = 30V AC/DC
Umax = 60V AC/DC
Umax = 300V AC/DC
max.
20A
max.
20A
E
F1 F2 F3
E
F1 F2
Controls
max.
20A
Indicators (LEDs)
E
F3
F1 F2 F3
Businterface
Overvoltage cat.
Rated surge voltage
Supply
U • Err • Com
Standard bus (RS485)
III (in accordance with IEC 60664-1)
III (in accordance with IEC 60664-1)
6kV
6kV
24V DC from local interface
24V DC from local interface
Output
-
-
Width
22,5mm
22,5mm
CE • GOST
CE • GOST
Certiicates
Mechanical
Design
Terminal capacity
Width 22,5mm
U • Err • Com
Standard bus (RS485)
Dimensions
Ambient
conditions
Accessories
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
7
Page 166
w w w. tel e-o n l i n e. co m
Page 167
WatchDog pro module for voltage measurement in 3-phase mains for 3- and 4-wire circuits. Monitoring of phase failure, phase sequence
and asymmetry.
WatchDog pro
Functions
Monitoring voltage in 3-phase mains
<
Measuring shunt voltage in 3-phase mains
<
Common reference potential (GND)
<
Reinforced isolation between the measuring circuit and the local interface
<
Measured value transmission via standard bus
<
Modular monitoring system
<
Width 22,5mm
<
Industrial design
Connections
G2PI1
1
G2YI3 60mV
Type
F1-3
max. 20A
N
L1 L2 L3
U1
U13
U3
3
U12
U2
U23
Art.No. (PQ1)
2
2500070
Art.No. (PQ10)
9008662006744
EAN13-Code
Width 22,5mm
Measured variable
Voltage
DC or AC Sinus (48 bis 63Hz)
Measured ranges
3 x 60mV AC/DC
terminals E-F1(+) • E-F2(+) • E-F3(+)
Dimensions
Address adjustment:
Address range 1 to 99
Controls
U • Err • Com
Indicators (LEDs)
Standard bus (RS485)
Businterface
Overvoltage cat.
III (in accordance with IEC 60664-1)
Rated surge voltage
6kV
Supply
24V DC from local interface
Output
-
Width
7
Mechanical
Design
Terminal capacity
Ambient
conditions
Accessories
Page 168
45mm
Certiicates
CE • GOST
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
w w w. tel e-o n l i n e. co m
Page 169
WatchDog pro
Functions
WatchDog pro module for measuring voltage in 3-phase mains.
Current monitoring in 1-phase mains
<
Current measurement in 1-phase mains
<
Measuring range from 20mA and 5A (G2II1 5A)
<
Measuring range from 100mA to 10A (G2II1 10A)
<
Reinforced insulation of the measuring circuit
<
Measured value transmitting via standard bus
<
Modular monitoring system
<
Width 22,5mm
<
Industrial design
Connections
Last
Shunt
Last
U1(+)
L1
U2(+)
L2
U3(+)
L3
GND(-)
N
E
F1 F2
Shunt
Type
G2II1 5A
G2II1 10A
Art.No. (PQ1)
2500251
2500250
Art.No. (PQ10)
-
-
900866200511
900866200491
Measured variable
Current
DC or AC Sinus (16,6 to 400Hz)
Current
DC or AC Sinus (16,6 to 400Hz)
Measured ranges
20mA AC/DC; terminals K-I1(+)
1A AC/DC; terminals K-I2(+)
5A AC/DC; terminals K-I3(+)
100mA AC/DC; terminals K-I1(+)
1A AC/DC; terminals K-I2(+)
10A AC/DC; terminals K-I3(+)
Address adjustment:
Address range 1 to 99
Address adjustment:
Address range 1 to 99
E
F3
F1 F2
F3
EAN13-Code
Width 22,5mm
Dimensions
Controls
Indicators (LEDs)
Businterface
Overvoltage cat.
Rated surge voltage
Supply
7
U • Err • Com
Standard bus (RS485)
III (in accordance with IEC 60664-1)
III (in accordance with IEC 60664-1)
6kV
6kV
24V DC from local interface
24V DC from local interface
Output
-
-
Width
22,5mm
22,5mm
CE • GOST
CE • GOST
Certiicates
Mechanical
Design
Terminal capacity
Ambient
conditions
Accessories
Page 170
U • Err • Com
Standard bus (RS485)
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
w w w. tel e-o n l i n e. co m
Page 171
Measured range 20mA
Measured range 1A
+
Last
WatchDog pro
Functions
WatchDog pro module for current monitoring in 1-phase mains.
L1
N
N
<
Current measurement in 3-phase mains
<
Reinforced insulation of the measuring circuit
<
Measured value transmitting via standard bus
<
Modular monitoring system
<
Width 22,5mm
<
Industrial design
Connections
Measured range 5A
L1
Current monitoring in 3-phase mains
G2II1 5A
Type
G2JI1 5A
G2JI1 1A
Art.No. (PQ1)
2500400
2500401
Art.No. (PQ10)
-
-
900866200526
9008662006331
Measured variable
Current
AC Sinus (48 to 63Hz)
Current
AC Sinus (48 to 63Hz)
Measured ranges
3 x 5A AC; terminals K-I1, K-I2, K-I3
3 x 1A AC; terminals K-I1, K-I2, K-I3
Address adjustment:
Address range 1 to 99
Address adjustment:
Address range 1 to 99
U • Err • Com
U • Err • Com
-
K
K
I1
I2
I1
I3
I2
K
I3
I1
I2
I3
EAN13-Code
Measured range 100mA
Measured range 1A
L1
L1
L3
L2
L2
N
L3
L3
N
N
L1
Connections
Measured range 10A
G2II1 10A
L2
Controls
Indicators (LEDs)
Standard bus (RS485)
Standard bus (RS485)
III (in accordance with IEC 60664-1)
III (in accordance with IEC 60664-1)
6kV
6kV
Supply
24V DC from local interface
24V DC from local interface
Output
-
-
Width
22,5mm
22,5mm
CE • GOST
CE • GOST
Businterface
K
I1
I2
I3
K
I1
I2
Overvoltage cat.
K
I3
I1
I2
I3
Rated surge voltage
Certiicates
Mechanical
Design
Terminal capacity
Width 22,5mm
Dimensions
Ambient
conditions
Accessories
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
7
Page 172
w w w. tel e-o n l i n e. co m
Page 173
G2JI1 5A without current transformer with common return
Last
WatchDog pro
Functions
WatchDog pro module for current measurement in 3-phase mains.
G2JI1 5A with current transformer with common return
True power monitoring
<
True power measurement of 1- or 3-phase loads
<
Measurement ranges from 600W to 4,8kW
<
Range adjustment via Central Unit
<
Measured value transmitting via standard bus
<
Modular monitoring system
<
Width 22,5mm
<
Industrial design
Connections
L1
L1
L2
L3
N
G2BI1 400V12A
Type
L2
L3
K
K
I1
I2
I3
I1
I2
I3
Art.No. (PQ1)
2500300
Art.No. (PQ10)
900866200489
EAN13-Code
Measured variable
Width 22,5mm
True power of 1- or 3-phase loads
AC Sinus (10 to 400Hz)
Dimensions
P • I1
Measured values
True power ranges PN
0,6kW • 1,2kW • 2,4kW • 4,8kW
Voltage ranges
1-phase loads: to 415VAC
3-phase loads: to 415/240VAC
Current ranges
Ranges 0,6 and 1,2kW: 6A
Ranges 2,4 and 4,8kW: 12A
Address adjustment:
Address range 1 to 99
Controls
U • Err • Com
Indicators (LEDs)
Standard bus (RS485)
Businterface
Overvoltage cat.
7
III (in accordance with IEC 60664-1)
Rated surge voltage
6kV
Supply
24V DC from local interface
Output
-
Width
22,5mm
Certiicates
Mechanical
Design
Terminal capacity
Ambient
conditions
Accessories
Page 174
CE • GOST
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
w w w. tel e-o n l i n e. co m
Page 175
WatchDog pro
Functions
True power monitoring of 1- and 3-phase loads
G2BI1 400V12A in 1-phase mains
Connections
G2BI1 400V12A in 3-phase mains
Power factor and power measurement
<
Power factor and power measurement in 1- or 3-phase mains
<
RMS measurement of one phase voltage and current of one phase
<
Monitoring of motor / generator / capacitive / inductive loads
<
2 Measurement range 1,2kW and 4,8kW
<
Measurement range adjustment via Central Unit
<
Reinforced insulation of the measuring circuits
<
Measured value transmitting via standard bus
<
Width 22,5mm
<
Industrial design
G2CI1 400V12A
Type
N
i
k
L1 L2 L3
i
k
L1 L2 L3
Art.No. (PQ1)
2500450
Art.No. (PQ10)
9008662005877
EAN13-Code
Phase voltage = 3 x U1
True power • Apparent power • Reactive power • Power factor • Phase voltage • Phase current
AC Sinus (10 to 400Hz)
Measured variable
G2BI1 400V12A in 3-phase mains with current transformer
Connections
PF, P, S, Q, U eff, Ieff
Measured values
L1
6A • 12A
Measuring input current
1,2kW • 4,8kW
Measured range
L2
L3
1-phase loads: to 415VAC
3-phase loads: to 415/240VAC
Voltage range
i
k
Address adjustment:
Address range 1 to 99
Controls
L1 L2 L3
U • Err • Com
Indicators (LEDs)
Standardbus (RS485)
Businterface
Overvoltage cat.
III (in accordance with IEC 60664-1)
Rated surge voltage
6kV
Supply
24V DC from local interface
Output
-
Width
22,5mm
Certiicates
Width 22,5mm
Dimensions
Mechanical
Design
Terminal capacity
Ambient
conditions
Accessories
CE • GOST
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
7
Page 176
w w w. tel e-o n l i n e. co m
Page 177
G2CI1 400V12A in 1-phase mains
N
i
k
G2CI1 400V12A in 3-phase mains with current transformer
Temperature monitoring
<
4 temperature measurement inputs with PT100 / PT1000 sensors
<
Error indicators for short circuit and line break
<
2 and 3-wire connection
<
Reinforced isolation between the input circuit and the local interface
<
Measured value transmission via standard bus
<
Modular monitoring system
<
Width 22,5mm
<
Industrial design
Connections
G2CI1 400V12A in 3-phase mains
L1 L2 L3
WatchDog pro
Functions
Power monitoring and measurement of power factor of 1- and 3-phase loads
i
Type
G2TI4 PT
k
L1 L2 L3
Art.No. (PQ1)
2500160
Art.No. (PQ10)
-
EAN13-Code
-
Measured variable
Temperature measurement PT100 or PT1000 (4-fold)
2-wire (with external bridge) and 3-wire connection
Measured ranges
-100°C to +300°C
-200°C to +850°C
Connections
L1
Address adjustment:
Address range 1 to 99
Controls
L2
L3
U • Err • Com • 1PT • 2PT • 3PT • 4PT
Indicators (LEDs)
i
k
Standard bus (RS485)
Businterface
L1 L2 L3
Overvoltage cat.
III (in accordance with IEC 60664-1)
Rated surge voltage
4kV
Supply
24V DC from local interface
Output
-
Width
22,5mm
Certiicates
Mechanical
Design
Terminal capacity
Width 22,5mm
Dimensions
Ambient
conditions
Accessories
CE • GOST
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
7
Page 178
w w w. tel e-o n l i n e. co m
Page 179
3-wire measuring method
PT100 / PT1000
1PT1 1PT2 1PT3
1PT1 1PT2 1PT3
2PT1 2PT2 2PT3
2PT1 2PT2 2PT3
3PT1 3PT2 3PT3
3PT1 3PT2 3PT3
4PT1 4PT2 4PT3
4PT1 4PT2 4PT3
PT100 / PT1000
Digital Input
<
4 digital inputs with common ground (COM)
<
Reinforced insulation of the input circuit
<
Digital state transmitting via standard bus
<
Modular monitoring system
<
Width 22,5mm
<
Industrial design
Connections
2-wire measuring method
PT100 / PT1000
WatchDog pro
Functions
WatchDog pro module with 4 temperature measurement inputs PT100 / PT1000.
G2DI4 24V
G2DI4 230V
G2DI4 SC
Art.No. (PQ1)
2500100
2500101
2500103
Art.No. (PQ10)
-
-
-
900866200330
900866200493
900866200492
Input circuit
Voltage AC/DC
AC Sinus (48 to 63Hz)
Voltage AC
AC Sinus (48 to 63Hz)
for potential free inputs
NPN sensors
Switch point
On / Off
DC: 9,3V / 5,3V
AC: 12,4V / 9,2V
AC: 153V / 53V
-
Address adjustment:
Address range 1 to 99
Address adjustment:
Address range 1 to 99
Address adjustment:
Address range 1 to 99
U • Err • Com • DI1 • DI2 • DI3 • DI4
U • Err • Com • DI1 • DI2 • DI3 • DI4
U • Err • Com • DI1 • DI2 • DI3 • DI4
Standard bus (RS485)
Standard bus (RS485)
Standard bus (RS485)
III (in accordance with IEC 60664-1)
III (in accordance with IEC 60664-1)
III (in accordance with IEC 60664-1)
Type
PT100 / PT1000
EAN13-Code
Width 22,5mm
Dimensions
Controls
Indicators (LEDs)
Businterface
Overvoltage cat.
Rated surge voltage
6kV
6kV
6kV
Supply
24V DC from local interface
24V DC from local interface
24V DC from local interface
Output
-
-
-
Width
7
Certiicates
Mechanical
Design
Terminal capacity
Ambient
conditions
Accessories
Page 180
22,5mm
22,5mm
22,5mm
CE • GOST
CE • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
w w w. tel e-o n l i n e. co m
Page 181
G2DI4 24V
WatchDog pro
Functions
WatchDog pro module with 4 digital inputs.
Overtemperature monitoring
<
Temperature monitoring
<
4 PTC inputs
<
Short circuit monitoring of the PTC inputs
<
Reinforced insulation of the input circuit
<
State transmission over Standard bus
<
Modular monitoring system
<
Width 22,5mm
<
Industrial design
Connections
G2DI4 230V
GND
N
24V
L
G2DI4 PTCK
Type
DI1 COM
DI1 COM
DI2 COM
DI2 COM
DI3 COM
DI3 COM
DI4 COM
DI4 COM
Art.No. (PQ1)
2500102
Art.No. (PQ10)
900866200494
EAN13-Code
Input circuit
PTC (Motor temperature)
max. 6 PTC sensors per input
Connections
G2DI4 SC
Measured ranges
Initial resistance <1,5kΩ
Measuring voltage
max. 5V; ≤2,5V DC at RPTC ≤4kΩ
Address adjustment:
Address range 1 to 99
Controls
DI1 COM
Indicators (LEDs)
U • Err • Com • 1T • 2T • 3T • 4T
DI2 COM
Response value
>3,6kΩ
Release value
<1,8kΩ
Short circuit monitoring
20Ω ± 10Ω
Standard bus (RS485)
Businterface
Overvoltage cat.
III (in accordance with IEC 60664-1)
Rated surge voltage
DI3 COM
6kV
Supply
DI4 COM
24V DC from local interface
Output
-
Width
22,5mm
Certiicates
Width 22,5mm
Dimensions
Mechanical
Design
Terminal capacity
Ambient
conditions
Accessories
CE • GOST
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
7
Page 182
w w w. tel e-o n l i n e. co m
Page 183
WatchDog pro Modul with 4 digital inputs for temperature monitoring with max. 6PTC.
WatchDog pro
Functions
Digital input
<
8 digital inputs with common reference potential
<
Inputs are compatible with EN 61131-2 - digital input type 1
<
Reinforced isolation between the input circuits and the local interface
<
Status transmission via standard bus
<
Modular monitoring system
<
Width 22,5mm
<
Industrial design
Connections
G2DI4 PTCK
PTC
PTC
1T1
1T2
2T1
2T2
G2DI8 24V
Type
PTC
PTC
PTC
PTC
PTC
PTC
PTC
3T1
3T2
4T1
4T2
PTC
PTC
Art.No. (PQ1)
2500105
Art.No. (PQ10)
9008662006577
EAN13-Code
Width 22,5mm
Input circuit
Voltage AC/DC
AC sinus (48 to 63Hz)
Controls
Address adjustment:
Address range 1 to 99
Dimensions
U • Err • Com • DI1 • DI2 • DI3 • DI4 • DI5 • DI6 • DI7 • DI8
Indicators (LEDs)
Standard bus (RS485)
Businterface
Overvoltage cat.
III (in accordance with IEC 60664-1)
Rated surge voltage
2,5kV
Supply
24V DC from local interface
Output
-
Width
22,5mm
Certiicates
7
Mechanical
Design
Terminal capacity
Ambient
conditions
Accessories
Page 184
CE • GOST
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
w w w. tel e-o n l i n e. co m
Page 185
WatchDog pro Modul with 8 digital inputs
WatchDog pro
Functions
Connections
Digital outputs
<
4 potential free digital relay or semiconductor outputs
<
Reinforced isolation between the outputs, relay version (G2DO4 R)
<
Functional isolation between the outputs, semiconductor version (G2DO4 S)
<
Short circuit protection of the outputs with error indicators (G2DO4 S)
<
Reinforced isolation between the output circuits and the local interface
<
Output state transmitting via standard bus
<
Modular monitoring system
<
Width 22,5mm
<
Industrial design
GND
24V
DI1
DI2
DI3
DI4
DI5
DI6
U+
DI7
DI8
U-
Type
G2DO4 R
G2DO4 SP24VDC
G2DO4 SN24VDC
Art.No. (PQ1)
2500200
2500201
2500203
Art.No. (PQ10)
-
-
-
900866200525
9008662005655
9008662005662
Address adjustment:
Address range 1 to 99
Address adjustment:
Address range 1 to 99
Address adjustment:
Address range 1 to 99
U • Err • Com • R1 • R2 • R3 • R4
U • Err • Com • O1 • O2 • O3 • O4
U • Err • Com • O1 • O2 • O3 • O4
EAN13-Code
Controls
Width 22,5mm
Dimensions
Indicators (LEDs)
Standard bus (RS485)
Standard bus (RS485)
Standard bus (RS485)
III (in accordance with IEC 60664-1)
III (in accordance with IEC 60664-1)
III (in accordance with IEC 60664-1)
6kV
2,5kV
2,5kV
Supply
24V DC from local interface
24V DC from local interface
24V DC for each output
24V DC from local interface
24V DC for each output
Output
4 potential free CO contacts
4 isolated PNP semiconductor outputs
4 isolated NPN semiconductor outputs
1250VA (5A / 250V)
2A / 24V DC
2A / 24V DC
22,5mm
22,5mm
22,5mm
CE • GOST
CE • GOST
CE • GOST
Businterface
Overvoltage cat.
Rated surge voltage
Switching capacity
Width
Certiicates
7
Mechanical
Design
Terminal capacity
Ambient
conditions
Accessories
Page 186
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
w w w. tel e-o n l i n e. co m
Page 187
Digital output
<
8 separate semiconductor outputs
<
Reinforced isolation between the output circuits and the local interface
<
Common reference potential for all output circuits
<
Short circuit protection of outputs with error display
<
Output state transmitting via standard bus
<
Modular monitoring system
<
Width 22,5mm
<
Industrial design
Connections
G2DO4 R
11
12
WatchDog pro
Functions
WatchDog pro module with 4 digital outputs
14
22
11
24
32
21
34
42
31
12
14
21 22
24
G2DO8 SPC24VDC
Type
44
41
31 32 34
Art.No. (PQ1)
41 42 44
Art.No. (PQ10)
2500205
9008662006584
EAN13-Code
Address adjustment:
Address range 1 to 99
Controls
G2DO4 SP24VDC
Connections
G2DO4 SN24VDC
U • Err • Com • O1 • O2 • O3 • O4 • O4 • O5 • O6 • O7 • O8 • Oerr
Indicators (LEDs)
Standard bus (RS485)
Businterface
Overvoltage cat.
III (in accordance with IEC 60664-1)
Rated surge voltage
24V DC
+
-
24V DC
+
RL
U1+
U1-
24V DC
+
RL
O1
U2+
U2-
24V DC
+
RL
O2
U3+
U3-
24V DC
+
RL
O3
U4+
U4-
24V DC
+
RL
O4
U1+
U1-
24V DC
+
RL
O1
U2+
U2-
24V DC
+
RL
O2
U3+
U3-
RL
O3
U4+
U4-
Supply
24V DC from local interface
Output
8 isolated PNP semiconductor outputs
Width
O4
Terminal capacity
Ambient
conditions
Accessories
Width 22,5mm
22,5mm
Certiicates
Mechanical
Design
G2DO4 SP24VDC and G2DO4 SN24VDC
2,5kV
CE • GOST
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
Connections
Dimensions
O1 U1- U1+
O2 U2- U2+
7
O3 U3- U3+
O4 U4- U4+
Page 188
w w w. tel e-o n l i n e. co m
Page 189
WatchDog pro module with 8 digital 24V PNP semi-conductor outputs.
WatchDog pro
Functions
Connections
O1 O2
Standard signal In- and Output
<
Analogue and digital input and output module for standard signals
<
Common ground (GND)
<
2 voltage inputs (0-10V DC / 0-24V DC / NPN / PNP)
<
2 current inputs (0-20mA DC)
<
1 output (0-20mA DC / 0-10V DC / 12V / 24V)
<
Reinforced insulation of the measuring circuits
<
Measured value transmitting via standard bus
<
Width 22,5mm
<
Industrial design
G2AM4 M
Type
O3 O4
O5 O6
O7 O8
U+
Art.No. (PQ1)
U-
Art.No. (PQ10)
2500600
9008662005631
EAN13-Code
Measured variable
Connections
Standard signals
Input
0-20mA DC; terminals INI3 / INI4
0-10V / 0-24V / PNP / NPN; terminals INU1 / INU2
Output
0-20mA DC / 0-10V DC / 12V DC / 24V DC; terminals OUT-GND
Address adjustment:
Address range 1 to 99
Controls
24V DC
U • Err • Com
Indicators (LEDs)
+
Standard bus (RS485)
Businterface
RL
RL
RL
RL
RL
RL
RL
Overvoltage cat.
RL
III (in accordance with IEC 60664-1)
Rated surge voltage
U+
U-
O1 U+
U-
O2 U+
U-
O3 U+
U-
O4
U+
U-
O5 U+
U-
O6 U+
U-
O7 U+
U-
O8
4kV
Supply
24V DC from local interface
Width
22,5mm
Certiicates
Mechanical
Design
Terminal capacity
Width 22,5mm
Dimensions
Ambient
conditions
Accessories
CE • GOST
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
7
Page 190
w w w. tel e-o n l i n e. co m
Page 191
Input signals:
0-10V DC, 0-24V DC, 0-20mA DC, NPN, PNP
Output signals:
0-10V DC, 0-20mA DC, 12V DC, 24V DC
G2AM4 M with voltage input signal
0 ... 10V DC
0 ... 24V DC
Connections
G2AM4 M with current input signal
=
0 ... 20mA
Fieldbus interface module
<
WatchDog pro ieldbus connection to the process level
<
Communication of I/O information to third party controls
<
Data transmission via high speed bus
<
Fieldbus interface modules are slaves on the ieldbus
<
Modbus-RTU; Standard connection to touch panels
<
Modbus-TCP
<
Proibus-DPV1
<
Width 22,5mm
<
Industrial design
G2FBC MB-RTU
G2FBC MB-TCP
G2FBC PB-DPV1
Art.No. (PQ1)
2500500
2500510
2500501
Art.No. (PQ10)
-
-
-
9008662005679
9008662005716
9008662005686
Type
INU1 GND INI3
INU1 GND INI3
INU2 GND INI4
INU2 GND INI4
OUT GND
OUT GND
Load
WatchDog pro
Functions
WatchDog pro module with digital inputs and analog in- and outputs for standard signals with a common ground (GND).
0-10V DC
0-20mA
12V DC
24V DC
Load
0-10V DC
0-20mA
12V DC
24V DC
EAN13-Code
Fieldbus
G2AM4 M with current and voltage input signal
G2AM4 M with 2 PNP-sensors (supplied via G2AM4 M)
Connections
Connector
Controls
0 ... 10V DC
0 ... 24V DC
=
=
0 ... 20mA
PNP-sensor
OUT1 OUT2
-
INU1
GND
INI3
INU2
GND
INI4
+
INU1
GND
INI3
INU2
GND
INI4
OUT
yes
yes
yes
Supply
24V DC from local interface
24V DC from local interface
24V DC from local interface
Width
22,5mm
22,5mm
22,5mm
CE • GOST
CE • GOST
CE • GOST
Connections, Dimensions
Accessories
G2FBC MB-RTU
0V
Address adjustment WatchDog pro:
Address range 1 to 99
Address adjustment Fieldbus:
Address range 1 to 126
U • Err • Com
Ambient
conditions
24V
Address adjustment WatchDog pro:
Address range 1 to 99
High speed bus (RS485)
Terminal capacity
Width 22,5mm
Baud rate
Address adjustment WatchDog pro:
Address range 1 to 99
Address adjustment Fieldbus:
Address range 1 to 247
U • Err • Com
2-wire-sensor
G2AM4 M with PNP-sensor and 4-20mA 3-wire-sensor
Sub-D (female)
High speed bus (RS485)
Mechanical
Design
GND
Proibus-DPV1
RJ45
U • Err • Com
Businterface
Certiicates
GND
Modbus-TCP
High speed bus (RS485)
Indicators (LEDs)
Galvanic separated
OUT
Modbus-RTU
Sub-D (female)
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27
STANDARD CABLE HMI/WDP RS485 5M • CABLE HMI/WDP RS485 5M
4-20mA
3-wire-sensor
PNP-sensor
INU1
GND
INI3
INU2
GND
INI4
7
OUT
Page 192
GND
w w w. tel e-o n l i n e. co m
Page 193
Measured values, alarms and system information are sent from WatchDog pro to controllers or the process level with the ield bus interface
module. Via the ieldbus interface, control signals, nominal values or thresholds can be sent to WatchDog pro too. For the connection of
WatchDog pro to touch panels with the Modbus-RTU interface module TELE provides cables as accessory.
G2FBC
WatchDog pro
Functions
Connections
Fieldbus gateways
<
Fieldbus connection between WatchDog pro modules and the process level
<
No central unit, no monitoring functions
<
Communication of measured values to third party controllers
<
Gateways are slaves on the ieldbus
<
Modbus-RTU
<
Modbus-TCP
<
Proibus-DPV1
<
Width 22,5mm
<
Industrial design
G2WDGW2 MB-RTU
G2WDGW2 MB-TCP
G2WDGW2 PB-DVP1
Art.No. (PQ1)
2500550
2500560
2500551
Art.No. (PQ10)
-
-
-
9008662005693
9008662005747
9008662005709
Type
EAN13-Code
Fieldbus
Width 22,5mm
Dimensions
Connector
Controls
Indicators (LEDs)
Businterface
Galvanic separated
Supply
Width
Certiicates
Mechanical
Design
7
Terminal capacity
Ambient
conditions
Accessories
Page 194
Modbus-RTU
Modbus-TCP
Proibus-DPV1
Sub-D (female)
RJ45
Sub-D (female)
Baud rate
Address adjustment Fieldbus:
Address range 1 to 247
-
Address adjustment Fieldbus:
Address range 1 to 126
U • Err • Com
U • Err • Com
U • Err • Com
Standard bus (RS485)
Standard bus (RS485)
Standard bus (RS485)
yes
yes
yes
24V DC
24V DC
24V DC
22,5mm
22,5mm
22,5mm
CE • GOST
CE • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
w w w. tel e-o n l i n e. co m
Page 195
Measured values from the WatchDog pro modules are put directly to the used ieldbus. The output modules are controlled with the ieldbus.
Monitoring and controlling tasks have to be managed with external controllers or in the process level.
WatchDog pro
Functions
Remote bus coupler
<
Distributed WatchDog pro system enlargement
<
System extension up to 99 modules
<
Up to 24 modules per remote bus coupler
<
Up to 40 remote bus couplers per Central unit
<
Bus length is limited with 500 meters (remote bus cable)
<
Width 22,5mm
<
Industrial design
Connections
G2WDGW2
GND
24V
G2RBC
Art.No. (PQ1)
2500700
Art.No. (PQ10)
GND
24V DC
Width 22,5mm
Type
90086620059
EAN13-Code
Dimensions
Interface
WatchDog pro remote bus
Terminals
Shld • RBA • RBB
Controls
RTER (terminator)
U • RTER
Indicators (LEDs)
WatchDog pro remote bus (RS485)
Businterface
Galvanic separated
yes
Supply
24V DC
Width
22,5mm
Certiicates
Mechanical
Design
Terminal capacity
7
Ambient
conditions
Accessories
Page 196
CE • GOST
Self-extinguishing plastic housing, IP rating IP20 • Mounted on DIN-rail TS 35 in accordance with EN 60715 • Mounting position: any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
• 2 x 2.5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1); -25 to +40°C (in accordance with UL 508) • Storage temperature: -25
to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Absolute
humidity: 1g to 25g H2O/m3 (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2 (in accordance with IEC 60664-1) • Vibration
resistance: 10 to 55Hz 0.35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27)
-
w w w. tel e-o n l i n e. co m
Page 197
DI
GND
13
DI4
14
24
DI2 SG STX SRX
23
DI1
24V
RB+ RBA RBB
DI3
RB
24V GND
Shld RBAi RBBi
Shld RBAo RBBo
24V GND
Shld RBAi RBBi
Shld RBAo RBBo
DC power
supply
DC power
supply
The remote bus coupler enables distributed WatchDog pro system enlargement. The central unit as well as the remote bus coupler are
able to supply 24 modules. The number of modules in one WatchDog pro system (Central unit and remote bus coupler) is limited by 99.
Page 198
Functions
Connections
Type
GP4105W1D
AGP3200-T1-D24
AST3201-AT-D24
AGP3300-S1-D24
AGP3301-S1-D24
AGP3302-B1-D24
AGP3400-T1-D24
AGP3400-S1-D24
AGP3500-T1-D24
Technical Data:
Display size
Inch/
mm
3,4/
86,4
3,8/
96,5
3,8/
96,5
5,7/
145
5,7/
145
5,7/
145
7,5/
188
7,5/
188
10,4/
264
Dimensions
B
H
T
16,5
77,5
28
130
104
41
130
104
41
167,5
135
59,5
167,5
135
59,5
167,5
135
59,5
215
170
60
215
170
60
270,5
212,5
57
STN
white; pink; red
TFT
Colour
Amber or red
STN
Colour
STN
Colour
Blue Mode
TFT
Colour
STN
Colour
TFT
Colour
Display-Type
Resolution [Pixel]:
200 x 80
n
320 x 240 (QVGA)
n
n
n
n
n
640 x 480 (VGA)
n
n
n
Colour
8 levels of grayscale
n
n
16 levels of grayscale
n
16 levels of bluescale
n
256 Colour
n
4.096 Colour
n
n
n
65.536 Colour
n
Interface
n
Seriell SIO (RS-232C)
Seriell SIO (RS-422/485)
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
CF-Cards
n
n
n
n
n
n
Expansion bus
n
n
n
n
n
n
n
n
n
n
n
USB
n
Ethernet
n
AUX/ Sound-Out
n
Articelnumber
542103
540113
540010
540124
540123
540120
540132
540131
540152
Type
GP4105W1D
AGP3200-T1-D24
AST3201-AT-D24
AGP3300-S1-D24
AGP3301-S1-D24
AGP3302-B1-D24
AGP3400-T1-D24
AGP3400-S1-D24
AGP3500-T1-D24
Page 199
Energymanagement Series ECO III
Maximum load controller
ECO - The system
The new EcoSys range in conjunction with the EcoGate expansion modules now makes it possible to
implement effective energy management cost effectively even in large sites. For the irst time, these devices
make it possible to record, assess and control the current consumption of a monitored building centrally
while performing the switching activity this requires on a decentralized basis directly in the individual
subdistributions. To achieve this, each EcoSys maximum peak load monitor can communicate with up to 7
EcoGate expansion modules through the standard protocol running over RS 485. In this way, up to 64
different consumers or consumer groups can be managed and switched on and off.
Type
ECO8 III SYS
ECO8 III GATE
Art.No. (PQ1)
620160
620161
EAN13-Code
900866200370
900866200371
Maximum load controller for allocation of power peaks.
Trend computation and limitation of peak power. Variable cycle durations after specification of the EVU adjustable or limitation of the instantaneous values. Amplification up to 64 consumer groups by dint of
ECO-GATE amplification modules.
Output extension unit to ECO-SYS.
The base device can be extended by 8 signal paths. Maximum 7
ECO GATE’s per ECO-SYS are lockable over decentral two-wire bus.
Connection facility for sub counter. Control contacts to inluence the
control mode of individual circuits.
integrated digital time switch for each channel • datalogger
integrated digital time switch for each channel
Functions
Additional functions
Controls
Indicators (LEDs)
Time ranges
4 button prgramming
4 button prgramming
Display • 8 LEDs for output status • Failure • Power
Display • 8 LEDs for output status • Failure • Power
min. turn-on time: 0s to 19min 59sec
min. turn-off time: 1s to 19min 59sec
max. turn-off time: 1s to 19min 59sec
min. turn-on time: 1s to 19min 59sec
min. turn-off time: 1s to 19min 59sec
max. turn-off time: 1s to 19min 59sec
Priority of outputs
64 levels of priority selectable
64 levels of priority selectable
Control input PWR
Function: power pulse from energy meter
Connected: galvanic separated; terminals 28, 29
Typ: S0 (DIN 43864); 12,5mA DC / 15V DC (max. 50Hz)
Function: Connection from sub energy meter
Connected: galvanic separated; terminals 28, 29
Typ: S0 (DIN 43864); 12,5mA DC / 15V DC (max. 50Hz)
Control input SYNC: pulse for synchronisation from the grid operator
Connected: galvanic separated; terminals 30, 31
Typ: S0 (DIN 43864); 12,5mA DC / 15V DC
Control input TAR: changing tariff input from the grid operator
Connected: galvanic separated; terminals 32, 33
Typ: S0 (DIN 43864); 12,5mA DC / 15V DC
Control input CLK: synchronisation of the clock (optional)
Connected: galvanic separated; terminals 34, 35
Typ: current loop; 6,25mA DC / 15V DC
Control input MOFF: turn off all loads immediately (optional)
Connected: galvanic separated; terminals 36, 37
Typ: current loop; 6,25mA DC / 15V DC
Control input IN1 to IN5
control outputs 1 to 5 (according to program settings)
Connected: galvanic separated; terminals 30 to 39
Typ: current loop; 6,25mA DC / 15V DC
Additional
control input
Supply
110 to 240V AC or 110 to 300V DC; terminals A1-A2
110 to 240V AC or 110 to 300V DC; terminals A1-A2
Output
8 potential free NO contact 230V AC, 3A (control load groups)
1 potential free CO contact 230V AC, 3A (failure)
8 potential free NO contact 230V AC, 3A (control load groups)
1 potential free CO contact 230V AC, 3A (failure)
Width
157,5mm
157,5mm
CE
CE
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position: any • Shockproof
terminal connection according to VBG 4, IP rating IP20 • recommended/max.wire stripping for terminal connection: 6mm/9mm
1 x 0,5 to 2,5mm² lexible without multicore cable end • 2 x 0,5 to 1,5mm² lexible without multicore cable end • 1 x 1 to 2,5mm² starr/with
multicore cable end
Ambient temperature: 0 to 50°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to +70°C •
relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC 60664-1)
ECO III COM (Art.Nr. 620170) for PC-Communication, Datalogger reading and parameter settings via RS232 or USB-Port
Content: converter RS232/RS485 and USB/RS232; adapter 9pin/25pin; datacable 9pin (1m); Software on CD ROM
w w w. tel e-o n l i n e. co m
Page 201
In most residential as well as in commercial buildings, the operation of some devices might be disabeled a few minutes without
inconvenience of comfort and functionality. Eco takes advantage of this by disconnecting „loads“ such as heating of rooms or hot water
provision for short periodes. As soon as the consumer system being monitored is again drawing less power, users that had previously been
disconnected are progressively reconnected and can continue operating.
The overall result is a significantly more consistent power uptake by the entire monitored consuming system – the plant’s power
requirement is reduced.
Sequence processor with 4x20 programm steps
<
Function of control inputs programmable
<
7 operation modes
<
Remanent latch function (selectable)
<
8 NO contact
<
1 CO contact
<
Width 157,5mm
<
Installation design
RS485 interface (B=RS485-)
RS485 interface (A=RS485+)
RS485 interface (B=RS485-)
RS485 interface (A=RS485+)
24V direct current supply
STEP-T8 110VAC
STEP-T8 230VAC
Art.No. (PQ1)
454002
454001
Art.No. (PQ10)
-
-
900866200365
900866200364
49 50 51 52 53 54
A B A B
24V
CLK
<
Type
MOFF
GND
PWR SYNC TAR
Ground
Disconnection
all load
Synchronisation
of the real time clock
Tariff change-over
28 29 30 31 32 33 34 35 36 37
State machine
Connections
Connections
Synchronisation impulse
Control inputs
Power pulse of
an energy meter
Sequence processor Series STEP-T8
Functions
ECO - How it works
EAN13-Code
Controls
Connections
Outputs
4 button programming
4 button programming
Display • 8 LEDs for output status • AL/SYNC • Power
Display • 8 LEDs for output status • AL/SYNC • Power
Sequence processor with 4x20 programm steps
7 operation modes selectable:
MODE 0 (standard - factory default) • MODE 1 (power failure detection)
• MODE 2 (start requirement) • MODE 3 (power failure detection and
start requirement) • MODE 4 (standard with extended Stop-function) •
MODE 5 (power failure detection with extended Stop-function) • MODE
6 (start requirement with extended Stop-function) • MODE 7 (power
failure detection and start requirement with extended Stop-function)
Sequence processor with 4x20 programm steps
7 operation modes selectable:
MODE 0 (standard - factory default) • MODE 1 (power failure detection)
• MODE 2 (start requirement) • MODE 3 (power failure detection and
start requirement) • MODE 4 (standard with extended Stop-function) •
MODE 5 (power failure detection with extended Stop-function) • MODE
6 (start requirement with extended Stop-function) • MODE 7 (power
failure detection and start requirement with extended Stop-function)
0,1s to 59min 59,9sec (100ms resolution)
1s to 99h 95min 59sec (1s resolution)
0,1s to 59min 59,9sec (100ms resolution)
1s to 99h 95min 59sec (1s resolution)
Control input I1: RESET
Connected: galvanic separated; terminals 28-29
Typ: S0 (DIN 43864); 15mA DC / 24V DC
Control input I2: TRIGGER
Connected: galvanic separated; terminals 30-31
Typ: S0 (DIN 43864); 15mA DC / 24V DC
Control input I3: STOP
Connected: galvanic separated; terminals 32-33
Typ: S0 (DIN 43864); 15mA DC / 24V DC
Control input I1: RESET
Connected: galvanic separated; terminals 28-29
Typ: S0 (DIN 43864); 15mA DC / 24V DC
Control input I2: TRIGGER
Connected: galvanic separated; terminals 30-31
Typ: S0 (DIN 43864); 15mA DC / 24V DC
Control input I3: STOP
Connected: galvanic separated; terminals 32-33
Typ: S0 (DIN 43864); 15mA DC / 24V DC
RESTART / STEP BACK • MANUAL • PROGRAMME CHANCE
RESTART / STEP BACK • MANUAL • PROGRAMME CHANCE
Supply
110VAC
terminals A1-A2
230VAC
terminals A1-A2
Output
8 potential free NO contact 230V AC, 3A
1 potential free NC contact 230V AC, 3A
8 potential free NO contact 230V AC, 3A
1 potential free NC contact 230V AC, 3A
Width
157,5mm
157,5mm
CE
CE
Indicators (LEDs)
Sammelstörmeldung
Regelausgänge
Functions
F
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
time ranges
factory default
control input setting
selectable Input functions
Width 157,5mm
Dimensions
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 202
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position: any • Shockproof
terminal connection according to VBG 4, IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
Ambient temperature: 0 to 50°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to +70°C •
relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC 60664-1)
-
w w w. tel e-o n l i n e. co m
Page 203
The 8 normally open contacts, as well as the alarm or synchronisation contact, are operated according to the internally saved,
time-dependent sequences of steps (programmes). The sequences can run once (E) or cyclically (Z).
The individual steps are defined by a programmed time interval and the associated condition of all output relays (output mask). Any
changes to the condition of the output relays therefore require the programming of a new step.
The time-controlled processing of the sequence can be influenced by using the 3 input channels. The product is supplied with a factory
default setting.
Connections
Control input
Pump Alternator Series GAMMA
Functions
factory default
RESET, TRIGGER, STOP
Alternating or prallel operation of motors
<
Alternated access of two pumps or other devices
<
Even distribution of duty
<
Parallel duty at high demand
<
Operation using 1 or 2 input signals (two modes of operation)
<
Timing offset of the two loads to avoid water hammer effects
<
Supply voltage selectable via TR2 PowerModules or DC power supply
<
2 separate change over relays for device control
<
Width 22,5mm
<
Industrial design
Type
Art.No. (PQ1)
G2ASMA20
122000
Art.No. (PQ10)
EAN13-Code
Controls
Connections
Outputs
Indicators (LEDs)
Functions
900866200033
TIME/MODE
U/t • Failure • R1 • R2
One of two redandant motors will operate on demand signalised by input Y1. Successive requests will operate the motors in an alternating
sequence (sharing the duty between the devices). On demand both devices (pumps) will operate in parallel:
Mode A (parallel operation by separate input signal): Input Y2 initiates parallel operation. Without signal at input Y2, only one single motor will
operate at each request.
Mode B (parallel operation by timing): If an operation request on input Y1 exceeds the ajdusted delay, the unit will start the second motor for
parallel operation.
Contactors
Supply voltage
Time ranges
t1 (for parallel operation): 2s to 5min (only for mode B)
t2 (offset timing): 2s ixed
Control input
control input Y1: request for operation; terminals Y1-Y3
control input Y2: parallel operation (Mode A only); terminals Y2-Y3
input circuits galvanic separated
Supply
PowerModule TR2 or SNT2
terminals A1-A2
Output
2 potential free CO contacts
250V AC, 5A
Width
22,5mm
Certiicates
Width 157,5mm
Dimensions
Mechanical
design
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required) • IP rating IP20 • Tightening torque max. 1Nm.
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1); -25 to 40°C (in accordance with UL 508) • Storage temperature: -25 to
+70°C • Transport temperature: -25 to +70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree:
3 (in accordance with IEC 60664-1) • Vibration resistance: 10 to 55Hz 0,35mm (in accordance with IEC 60068-2-6) • Shock resistance: 15g
11ms (in accordance with IEC 60068-2-27)
Accessories
Page 204
CE
PowerModulee TR2 (12 - 440V AC) • DC power supply SNT2 24VDC
w w w. tel e-o n l i n e. co m
Page 205
The Pump-Alternator is sensitive to one (mode B) or two (mode A) digital input signals. Each of the two output relays activates one of the
two devices (usually pumps or motors) driven. The two outputs (Rel.1 and Rel. 2), are equally configured and interchangeable. In case of
request for operation (Y1-Y3 linked by external contact) one of the output relays energises as long as the signal persists on input (Y1). Next
time there is a request for operation the alternate output operates in the same manner. This way both connected devices (pumps or motors)
will share load.
The information about, which output has done the first cycle after a power reset, is stored in a non-volatile memory. Next time after a power
reset the other output will do the first cycle.
There is no definite delivery status about which of the two outputs will operate at the first occasion.
Mode and time setting can be done with a screwdriver at the front of the G2ASMA20. Control by supply voltage.
Functions
Modus A
Connections
Modus B
L1
L2
L3
L1
L2
L3
A1
15
K1
K2
A1
Y1 Y3 Y2
G2ASMA20
15
1
15
K1
K2
Y1 Y3 Y2
M
3~
25
2
M
3~
G2ASMA20
15
1
16 18 26 28
16 18 26 28
25 26 28
25 26 28
16 18 A2
M
3~
25
2
M
3~
16 18 A2
K2
K2
K1
K1
N
N
Connections
Control by supply voltage
L1
L2
L3
A1
15
K1
K2
Y1 Y3 Y2
G2ASMA20
15
1
M
3~
25
2
M
3~
16 18 26 28
25 26 28
16 18 A2
K2
K1
N
Width 22,5mm
Page 206
Dimensions
Page 207
POWER
ELECTRONICS
OVERVIEW
Page
Softstarter
Devices for different power classes are available for
continuously optimized startups and shutdowns and
for eliminating sudden stresses on conveyor systems,
- Series: TSG/MSG
- Series: EUROSTART
- Series: ESG
210
211
212
- Series: MBG
- Series: BG
214
214
- Series: TST
- Series: ESGT
215
216
elevators and pumps. Different models ranging from
compact devices with built-in bypass contactor
through to large modular units with current-limited
startup help to reduce maintenance costs.
Braking Units
The compact braking units from TELE can be used to
brake a wide variety of motor types easily, quickly and
safely without mechanical wear. Motors rated up to
400kW are braked by an electromagnetic ield without
additional mechanical components. Changeover
delays and interlocks ensure braking is performed
safely.
Thyristor Control Units
A simple, systematic and economical approach is
available for low-cost control and eficient regulation
of ventilation, heating and lighting systems. For
continuous and demand-based control for single- and
three-phase loads it is possible to use phase control
or in the case of heater elements, multicycle control.
By eliminating wear, you increase availability and
reduce costs.
w w w. tel e-o n l i n e. co m
Page 209
Softstarter Series TSG, MSG
Softstarter Series EUROSTART
Compact design
Compact design
<
Motor power 1,5 - 11kW
<
Motor power 1,5 - 75kW
<
Nominal voltage 400V AC or 230V (TSG)
<
Nominal voltage 110 - 500V AC
<
1-phase and 3-phase control
<
3-phase control
<
W3C-connection possible
<
Softstop
<
Reduced mechanical stress on drives (MSG)
<
Softstop (MSG)
<
PTC-Input (MSG 5,5/MSG 11)
<
DIN rail mounting
<
Integrated bypass contactor
TSG
MSG
Softstarter EUROSTART
Softstarter TSG and MSG
Motor control
1-phase
3-phase
EUROSTART
Art.No.
Motor control
TSG 2,2 230VAC
490251
3-phase
TSG 2,2 400VAC
490250
Type
Nominal
current
4A
Nominal
motor power
1,5kW
Dimension
H x B x T [mm]
200 x 83 x 106
Weight
Type
Art.No.
1,2kg
EUROSTART 1,5
490133
5A
2,2kW
200 x 83 x 106
1,2kg
EUROSTART 2,2
490134
Nominal
current
5A
Nominal
motor power
1,3kW (1~ 230V)
Dimension
H x B x T [mm]
75 x 22,5 x 111
Weight
0,2kg
5A
2,2kW (3~ 400V)
75 x 22,5 x 111
0,2kg
6A
3kW*
76 x 45 x 117
0,33kg
MSG 3-3s 400VAC
490000
7A
3,0kW
200 x 83 x 106
1,2kg
EUROSTART 3
490136
6A
3kW
76 x 45 x 117
0,33kg
MSG 3-30s 400VAC
490002
9A
4,0kW
200 x 83 x 106
1,2kg
EUROSTART 4
490135
11A
5,5kW
76 x 70 x 117
0,41kg
MSG 5,5 400VAC
490007
12A
5,5kW
200 x 83 x 106
1,2kg
EUROSTART 5,5
490137
22A
11kW
76 x 100 x 117
0,62kg
MSG 11 400VAC
490008
16A
7,5kW
200 x 85 x 205
2,2kg
EUROSTART 7,5
490139
Accessories
Type
Art.No.
23A
11kW
200 x 85 x 205
2,2kg
EUROSTART 11
490142
31A
15kW
200 x 85 x 205
2,2kg
EUROSTART 15
490145
39A
18,5kW
200 x 85 x 205
2,2kg
EUROSTART 18,5
490147
46A
22kW
200 x 85 x 205
2,2kg
EUROSTART 22
490149
Front cover MSG 3 (sealable)
FA-MSG 3
490245
64A
30kW
200 x 360 x 140
4,5kg
EUROSTART 30
490159
Front cover MSG 5,5 (sealable)
FA-MSG 5,5
490246
77A
37kW
200 x 360 x 140
4,5kg
EUROSTART 37
490175
Front cover MSG 11 (sealable)
FA-MSG 11
490247
* Max. start time 3s
94A
45kW
200 x 360 x 140
4,5kg
EUROSTART 45
490180
115A
55kW
200 x 360 x 140
4,5kg
EUROSTART 55
490185
155A
75kW
200 x 360 x 140
4,5kg
EUROSTART 75
490189
Options (integrated in the device)
Duty for motor powers 30-90kW (forced ventilation)
Page 210
w w w. tel e-o n l i n e. co m
Type
Art.No.
/DB EURO-30
AS0023
Page 211
Softstarter Series ESG
Open design
< < Motor power 2,2 - 560kW
AD
BREAK
< Nominal voltage 400 - 500V AC
< < 3-phase control
< < W3C-connection possible
< < Softstop
< Current limitation (ESG-I)
Softstarter ESG
Motor control
3-phase;
without current
limitation
3-phase;
with current
limitation
Nominal
current
Nominal
motor power
Dimension
H x B x T [mm]
Weight
Type
Art.No.
5A
2,2kW
200 x 140 x 115
1,3kg
ESG 2,2-400
490010
6A
3kW
200 x 140 x 115
1,4kg
ESG 3-400
490015
8,5A
4kW
200 x 140 x 115
1,5kg
ESG 4-400
490020
12A
5,5kW
160 x 260 x 170
2,8kg
ESG 5,5-400
490025
15A
7,5kW
160 x 260 x 170
2,8kg
ESG 7,5-400
490030
22A
11kW
160 x 260 x 170
3kg
ESG 11-400
490035
490040
30A
15kW
160 x 260 x 170
3kg
ESG 15-400
40A
18,5kW
160 x 260 x 170
3kg
ESG 18,5-400
490045
45A
22kW
160 x 260 x 170
3,5kg
ESG 22-400
490050
60A
30kW
200 x 360 x 200
8kg
ESG 30-400
490055
70A
37kW
200 x 360 x 200
8,5kg
ESG 37-400
490060
90A
45kW
200 x 360 x 200
8,5kg
ESG 45-400
490065
110A
55kW
200 x 360 x 200
9kg
ESG 55-400
490070
150A
75kW
200 x 360 x 200
9,5kg
ESG 75-400
490075
5A
2,2kW
200 x 140 x 115
1,3kg
ESG-I 2,2-400
490011
6A
3kW
200 x 140 x 115
1,4kg
ESG-I 3-400
490061
8,5A
4kW
200 x 140 x 115
1,5kg
ESG-I 4-400
490021
12A
5,5kW
160 x 260 x 170
2,8kg
ESG-I 5,5-400
490026
15A
7,5kW
160 x 260 x 170
2,8kg
ESG-I 7,5-400
490031
22A
11kW
160 x 260 x 170
3kg
ESG-I 11-400
490036
490041
30A
15kW
160 x 260 x 170
3kg
ESG-I 15-400
40A
18,5kW
160 x 260 x 170
3kg
ESG-I 18,5-400
490046
45A
22kW
160 x 260 x 170
3,5kg
ESG-I 22-400
490051
60A
30kW
200 x 360 x 200
8kg
ESG-I 30-400
490056
70A
37kW
200 x 360 x 200
8,5kg
ESG-I 37-400
490063
90A
45kW
200 x 360 x 200
8,5kg
ESG-I 45-400
490067
110A
55kW
200 x 360 x 200
9kg
ESG-I 55-400
490072
490076
150A
75kW
200 x 360 x 200
9,5kg
ESG-I 75-400
180A
90kW
200 x 360 x 200
10,5kg
ESG-I 90-400
490081
200A
110kW
400 x 360 x 240
18kg
ESG-I 110-400
490085
230A
140kW
400 x 360 x 240
18kg
ESG-I 140-400
490093
300A
160kW
545 x 600 x 346
41kg
ESG-I 160-400
490096
490101
350A
200kW
545 x 600 x 346
41kg
ESG-I 200-400
450A
250kW
545 x 600 x 346
42kg
ESG-I 250-400
490110
550A
315kW
545 x 600 x 346
42kg
ESG-I 315-400
490111
700A
355kW
545 x 600 x 346
44kg
ESG-I 355-400
490112
800A
400kW
715 x 850 x 396
51kg
ESG-I 400-400
490113
1100A
560kW
715 x 850 x 396
53kg
ESG-I 560-400
490114
Type
Art.No.
Options (integrated in the device)
Duty for motor powers 2,2 - 4kW (forced ventilation)
/DB ESG-2,2
AS0015
Duty for motor powers 5,5 - 22kW (forced ventilation)
/DB ESG-5,5
AS0016
Duty for motor powers 30 - 75kW (forced ventilation)
/DB ESG-30
AS0017
Duty for motor powers 90 - 140kW (forced ventilation)
/DB ESG-90
AS0018
Braking module (ESG 3 and higher)
/BG ESG
AS0019
Control voltage; 24V DC
/24VDC ESG
AS0020
Control voltage; 400V AC
/400VAC ESG
AS0021
Page 212
w w w. tel e-o n l i n e. co m
Page 213
Thyristor control unit Series TST
Braking Units Series MBG, BG
Compact design
< < Electronic motor brake
< < No additional braking accessory required
BG
MBG20
< < Integrated brake contactor (MBG)
< < Integrated motor contactor control
Motor brake
Compact Design
Open Design
<
Max. load current 5 - 50A
<
1-phase control (TST1) and 3-phase control (TST3)
<
Phase clipping or burst control switchable (TST3)
<
Multi control signal (TST3)
<
For resistive and inductive loads
TST1
TST3
Thyristor control unit (Compact Design)
Recommended
motor power
2,2kW
Max. braking
current
10A
Dimension
H x B x T [mm]
76 x 45 x 117
Weight
Type
Art.No.
0,29kg
MBG10 230V AC
499110
5,5kW
20A
101 x 70 x 117
0,51kg
MBG20 400V AC
499111
11kW
35A
101 x 101 x 117
0,68kg
MBG35 400V AC
499112
25A
130 x 93 x 103
TST1 25
499992
4kW
18A
140 x 200 x 115
1,1kg
BG 20
499950
35A
130 x 93 x 103
TST1 35
499993
7,5kW
32A
140 x 200 x 115
1,2kg
BG 35
499951
15kW
60A
195 x 260 x 170
2,3kg
BG 60
499982
22kW
100A
195 x 260 x 170
2,5kg
BG 100
499981
15A
130 x 93 x 103
TST1-SP 15
499991S
30kW
150A
195 x 260 x 170
2,9kg
BG 150
499983
25A
130 x 93 x 103
TST1-SP 25
499992S
55kW
220A
195 x 260 x 170
3,4kg
BG 220
499984
35A
130 x 93 x 103
TST1-SP 35
499993S
75kW
300A
195 x 260 x 170
3,4kg
BG 300
499955
50A
130 x 93 x 103
TST1-SP 50
499994S
100kW
400A
235 x 360 x 200
6,9kg
BG 400
499956
140kW
500A
235 x 360 x 200
6,9kg
BG 500
499957
200kW
750A
235 x 360 x 200
7,4kg
BG 750
499977
25A
200 x 140 x 135
TST3 25 3x400/230V
499051
250kW
1000A
235 x 360 x 200
7,6kg
BG 1000
499959
35A
200 x 140 x 135
TST3 35 3x400/230V
499052
315kW
1500A
360 x 400 240
9,2kg
BG 1500
499985
50A
200 x 140 x 135
TST3 50 3x400/230V
499054
400kW
2000A
360 x 400 240
10,5kg
BG 2000
499986
Phase clipping control
Burst control
Phase clipping- and
Burst control
switchable
Load
max.
1-phase
1-phase
Type
5A
Dimension
H x B x T [mm]
130 x 93 x 103
Art.No.
TST1 05
499996
15A
130 x 93 x 103
TST1 15
499991
50A
130 x 93 x 103
TST1 50
499994
5A
130 x 93 x 103
TST1-SP 05
499996S
3-phase
5A
200 x 140 x 135
TST3 05 3x400/230V
499053
3- or 4-wire system
15A
200 x 140 x 135
TST3 15 3x400/230V
499050
Options
for Series
TST1
TST3
Page 214
Type
Art.No.
Internal power supply 230V AC
/IV 230VAC TST1
AS0029
Internal power supply 400V AC
/IV 400VAC TST1
AS0033
Internal power supply 400V AC (integrated in the device)
/400VAC TST3
AS0032
w w w. tel e-o n l i n e. co m
Page 215
Thyristor control unit Series ESGT
Thyristor control unit Series ESGT
Open design
Open design
< Max. Load current 8 - 1000A
<
Load current 8 - 350A
< < 3-phase control
<
1-phase control
< < Additional options provided by various function modules
<
Options provided by various function modules
< < For resistive or inductive load
<
For resistive or inductive load
Three-phase AC-controller (Open Design)
Phase clipping control
Burst control
Burst control
Page 216
AC-controller (Open Design)
Load
Max. load
current
Dimension
H x B x T [mm]
Weight
Type
Art.No.
3-phase
3- or 4-wire system
8A
15A
25A
35A
50A
60A
75A
90A
120A
160A
220A
280A
350A
420A
560A
720A
1000A
8A
15A
25A
35A
50A
60A
75A
90A
120A
160A
220A
280A
350A
420A
560A
720A
1000A
8A
15A
25A
35A
50A
60A
75A
90A
120A
160A
220A
280A
350A
420A
560A
720A
1000A
140 x 200 x 115
195 x 260 x 170
195 x 260 x 170
195 x 260 x 170
195 x 260 x 170
195 x 260 x 170
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
140 x 200 x 115
195 x 260 x 170
195 x 260 x 170
195 x 260 x 170
195 x 260 x 170
195 x 260 x 170
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
140 x 200 x 115
195 x 260 x 170
195 x 260 x 170
195 x 260 x 170
195 x 260 x 170
195 x 260 x 170
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
235 x 360 x 200
1,3kg
1,9kg
1,9kg
2,3kg
2,3kg
2,4kg
3,7kg
3,9kg
3,9kg
4,2kg
8,5kg
8,8kg
9,3kg
9,8kg
18kg
18kg
18,9kg
1,3kg
1,9kg
1,9kg
2,3kg
2,3kg
2,4kg
3,7kg
3,9kg
3,9kg
4,2kg
8,5kg
8,8kg
9,3kg
9,8kg
18kg
18kg
18,9kg
1,3kg
1,9kg
1,9kg
2,3kg
2,3kg
2,4kg
3,7kg
3,9kg
3,9kg
4,2kg
8,5kg
8,8kg
9,3kg
9,8kg
18kg
18kg
18,9kg
ESGT 08
ESGT 15
ESGT 25
ESGT 35
ESGT 50
ESGT 60
ESGT 75
ESGT 90
ESGT 120
ESGT 160
ESGT 220
ESGT 280
ESGT 350
ESGT 420
ESGT 560
ESGT 720
ESGT 1000
ESGT-SP 08
ESGT-SP 15
ESGT-SP 25
ESGT-SP 35
ESGT-SP 50
ESGT-SP 60
ESGT-SP 75
ESGT-SP 90
ESGT-SP 120
ESGT-SP 160
ESGT-SP 220
ESGT-SP 280
ESGT-SP 350
ESGT-SP 420
ESGT-SP 560
ESGT-SP 720
ESGT-SP 1000
ESGT-SP-N 08
ESGT-SP-N 15
ESGT-SP-N 25
ESGT-SP-N 35
ESGT-SP-N 50
ESGT-SP-N 60
ESGT-SP-N 75
ESGT-SP-N 90
ESGT-SP-N 120
ESGT-SP-N 160
ESGT-SP-N 220
ESGT-SP-N 280
ESGT-SP-N 350
ESGT-SP-N 420
ESGT-SP-N 560
ESGT-SP-N 720
ESGT-SP-N 1000
490200
490201
490213
490203
490216
490217
490218
490220
490205
490210
490212
490214
490215
490370
490373
490376
490379
490341
490343
490346
490349
490351
490353
490354
490355
490342
490344
490345
490348
490350
490371
490374
490377
490380
490356
490358
490361
490363
490365
490366
490367
490368
490357
490359
490360
490362
490364
490372
490375
490378
490381
3-phase
3-wire system
3-phase
4-wire system
Load
Phase clipping control 1-phase
Burst control
1-phase
Weight
8A
Dimension
H x B x T [mm]
140 x 200 x 115
1,0kg
ESGT-1PH 08
490300
15A
140 x 200 x 115
1,1kg
ESGT-1PH 15
490301
25A
140 x 200 x 115
1,5kg
ESGT-1PH 25
490310
35A
140 x 200 x 115
1,6kg
ESGT-1PH 35
490313
50A
195 x 260 x 170
2,8kg
ESGT-1PH 50
490315
60A
195 x 260 x 170
2,8kg
ESGT-1PH 60
490316
75A
195 x 260 x 170
3kg
ESGT-1PH 75
490317
90A
195 x 260 x 170
3kg
ESGT-1PH 90
490318
125A
195 x 260 x 170
3kg
ESGT-1PH 125
490320
Max. load
current
Type
Art.No.
220A
235 x 360 x 200
7,8kg
ESGT-1PH 220
490224
300A
235 x 360 x 200
8,8kg
ESGT-1PH 300
490312
350A
235 x 360 x 200
9,4kg
ESGT-1PH 350
490314
8A
140 x 200 x 115
1,0kg
ESGT-1PH-SP 08
490319
15A
140 x 200 x 115
1,1kg
ESGT-1PH-SP 15
490321
25A
140 x 200 x 115
1,5kg
ESGT-1PH-SP 25
490323
35A
140 x 200 x 115
1,6kg
ESGT-1PH-SP 35
490325
50A
195 x 260 x 170
2,8kg
ESGT-1PH-SP 50
490327
60A
195 x 260 x 170
2,8kg
ESGT-1PH-SP 60
490328
75A
195 x 260 x 170
3kg
ESGT-1PH-SP 75
490329
90A
195 x 260 x 170
3kg
ESGT-1PH-SP 90
490330
125A
195 x 260 x 170
3kg
ESGT-1PH-SP 125
490326
220A
235 x 360 x 200
7,8kg
ESGT-1PH-SP 220
490322
300A
235 x 360 x 200
8,8kg
ESGT-1PH-SP 300
490324
350A
235 x 360 x 200
9,4kg
ESGT-1PH-SP 350
490314S
Options
Load
Integrated in the device
3-phase
1-phase
Constant-current regulation, 3 current transformers
Type
Art.No.
/J ESGT
AS0008
Constant-voltage regulation
/U ESGT
AS0009
Current-limit control with high-speed disconnection
/IB ESGT
AS0010
Current output (0-100% nominal current equ. 0-10V)
/AI ESGT
AS0011
Voltage output 0-10V trimmable to nominal voltage
/AU ESGT
AS0012
Control voltage 24V DC
/24V DC ESGT
AS0013
Control voltage 400V AC
/400VAC ESGT
AS0014
Constant-current regulation, current transformer included
/J ESGT-1PH
AS0001
Constant-voltage regulation
/U ESGT-1PH
AS0002
Current-limit control with high-speed disconnection
/IB ESGT-1PH
AS0003
Current output (0-100% nominal current equ. 0-10V)
/AI ESGT-1PH
AS0004
Voltage output 0-10V trimmable to nominal voltage
/AU ESGT-1PH
AS0005
Control voltage 24V DC
/24V DC ESGT-1PH
AS0006
Control voltage 400V AC
/400VAC ESGT-1PH
AS0007
Accessories
Remote potentiometer, scale 1-10, 10KOhm
w w w. tel e-o n l i n e. co m
Type
Art.No.
R20 10KOHM
282131
Page 217
SWITCHING฀
RELAYS฀
OVERVIEW
AND฀OTHER฀
AUTOMATION฀
COMPONENTS
Page
Switching Relays
- Miniature Relays: RA and RM
- Industrial Relays: RT
- PCB Relays: RP
- Interface Relays: SKR
220
222
223
224
Coupling Units
- Coupling Relays: ENYA
- Automatic-Manual-OFF relay: OCTO
- Analogue data encoder: OCTO
- Levelswitch: OCTO
- Diode gate / logical operation: TREND
- Multicoupling relay: VOX
225
227
229
231
233
235
Signal Converter
- Signalamplifier: M1
- Loop-Powered Isolator: M1
237
239
Mains decoupler
- Series: OCTO
241
Safty Relays
- Safety Relays: S2
- Safety Relays: ZK
243
243
Digital Time Switches
- Series: TSC
244
Hour meters
- Series TBG and TBW
245
DC power supply
- Series: RNG
- Switching power supply
246
247
w w w. tel e-o n l i n e. co m
Switching Relays Series RA and RM
Miniature Relays
<
2 CO contacts, max. 12A switching current (Series RA)
<
4 CO contacts, max. 6A switching current (Series RM)
<
Various LED and protection modules
<
Hand operation
RA
RM
RSS214
Miniature Relays
Contacts
Nominal voltage
RA
2 CO
AC
DC
4 CO
PYF14BE3
PYF14BE
Modul M21P
Relay socket
Series
RM
PYF14BE3CC
ES 15/4B
AC
LED
protection
diode
gold-coated
contacts
Art.No.
Series
for series
Nominal voltage
PYF
RA, RM
300V AC
24V
n
RA 524L
100623LD
115V
n
RA 615L
100621LD
230V
n
RA 730L
100624LD
(cage clamp)
12V
n
RA 012L
100625LD
ES
RA, RM
24V
n
RA 024L
100622LD
RSS214
RM
12V
n
RM 512L
100612LD
for series
PYF
24V
n
RM 524
100613
RM 524L
100613LD
max. current Type
pro contact
12A
PYF14BE (ES 15/4N)
Art.No.
180134
12A
PYF14BE3 (ES 15/4S)
180145
10A
PYF14BE3CC (ES 15/4G)
180148
300V AC
10A
ES 15/4B
180046
300V AC
6A
RSS214
180050
Nominal voltage
Type
Art.No.
6 - 230V DC (+A2)
M21P
180260
6 - 230V DC (+A1)
M21N
180261
6 - 24V AC/DC (+A1)
M61R
180265
110 - 230V AC/DC (+A1)
M63R
180268
6 - 24V DC (+A2)
M31R
180262
6 - 24V DC (+A1)
M41R
180263
110 - 230V AC
EM 10
180307
6 - 24V AC/DC
EM 11
180308
Modules
RM 524.02L
100613H
48V
n
RM 548L
100614LD
115V
n
RM 615L
100618LD
RM 615.02L
100618H
RM 730
100619
RM 730L
100619LD
RM 730.02L
100619HL
RM 012L
100601LD
RM 012.02LD
100601HD
RM 024
100603
LED (green) + Diode
RSS214
6 - 24V DC (+A1)
EM 12
180309
RM 024L
100603LD
RC-element
PYF
110 - 240V AC
M53
180264
RM 024LD
100604FD
RSS214
110 - 230V AC
EM 03
180300
RM 024.02LD
100603HD
PYF
24V AC
M71
180266
RM 048L
100602LD
230V AC
M73
180267
RM 048.02LD
100602HD
24V AC
EM 04
180301
RM 060L
100616LD
230V AC
EM 05
180302
RM 060.02LD
100616HD
Varistor + LED (red)
PYF
110 - 230V AC
M93G
180276
RM 110L
100617LD
Resistor
PYF
110 - 230V AC
M103
180269
RM 110.02LD
100617HD
RM 220L
100620LD
RM 220.02LD
100619HF
n
n
n
n
230V
n
n
DC
Type
12V
n
n
n
n
n
24V
n
48V
n
n
n
n
n
n
60V
n
n
n
n
n
220V
n
n
n
110V
n
n
n
n
n
n
n
Diode
PYF
LED (red)
LED (red) + Diode
PYF
RSS214
LED (green)
Varistor
RSS214
Accessories
Retaining clip (metal)
for series
Type
Art.No.
RSS214, ES, PYF
HB/RM-RA
180032
Retaining clip (plastic)
ES, PYF
HB/ES15
P0000033
Jumper link
RSS214 (5 Relays)
PB RSS5
180051
End cover
for jumper link
PB RSS5
PBA RSS
180052
Relaysets
Contacts
4 CO
Nominal voltage
AC
24V
DC
24V
AC
Page 220
230V
Socket
Protection
RSS214 PYF14BE LED
diode
n
n
n
Retaining Type
clip HB/ES15
SET RM524L+PYF14BE
100670
SET RM024LD+RSS214
100680
n
SET RM024LD+PYF14BE
100671
n
SET RM730L+PYF14BE
100672
n
n
n
n
n
n
n
n
Art.No.
w w w. tel e-o n l i n e. co m
Page 221
Switching Relays Series RT
Switching Relays Series RP
Industrial Relays
PCB Relays
<
2 or 3 CO contacts, max. 10A switching current
<
1 CO contact, max. 16A switching current
<
8-pin or 11-pin socket
<
2 CO contacts, max. 8A switching current
<
Position indicator
<
Mounting in socket or on printed circuit boards (PCB)
<
Various LED and protection modules
<
Relaysets with socket and retaining clip
<
Hand operation
<
Various LED and protection modules
ES9
RT
R11X
TYPE11
Industrial relays
Nominal voltage
8-pin
AC
DC
11-pin
AC
2 CO
3 CO
protection
gold-coated
LED
diode
Type
Art.No.
12V
n
n
RT 1.2.012L
100508LD
24V
n
n
RT 1.2.024L
100507LD
110V
n
n
RT 1.2.110L
100505LD
230V
n
n
RT 1.2.230L
100502LD
12V
n
n
RT 2.2.012L
100517LD
24V
n
n
RT 2.2.024L
100516LD
24V
n
n
RT 1.3.024L
100526LD
48V
n
n
RT 1.3.048L
100524LD
110V
n
n
RT 1.3.110L
100522LD
230V
n
n
n
DC
12V
n
24V
n
n
n
n
n
Contacts
Nominal voltage
Current
Type
Art.No.
1 CO
AC
24V AC
16A
RP 524-1
100431
230V AC
16A
RP 730-1
100432
DC
24V DC
16A
RP 024-1
100430
AC
24V AC
8A
RP 524-2
100417
115V AC
8A
RP 615-2
100421
230V AC
8A
RP 730-2
100418
RP 730-hv
100418H
2 CO
DC
100420
RP 024-2
100416
RP 024-hv
100416H
8A
Series
for Series
Nominal voltage
max. current pro contact
Type
Art.No.
n
RT 1.3.230.02L
100521H
PI
RP
300V AC
12A
PI50BE (ES 50)
180137
n
RT 2.3.012L
100536LD
12A
PI50BE3 (ES 50/3)
180133
RT 2.3.024
100535
12A
PSS8/3
180056
RT 2.3.024L
100535LD
PSS
RP
300V AC
n
n
RT 2.3.024LD
100535FD
Modules
n
n
RT 2.3.024.02LD
100535H
Typ
for Series
Nominal voltage
Type
Art.No.
Diode
PI
6 - 230V DC (+A2)
M21P
180260
6 - 230V DC (+A1)
M21N
180261
6 - 24V AC/DC (+A1)
M61R
180265
110 - 230V AC/DC (+A1)
M63R
180268
6 - 24V DC (+A2)
M31R
180262
6 - 24V DC (+A1)
M41R
180263
110 - 230V AC
EM 10
180307
6 - 24V AC/DC
EM 11
180308
RT 2.3.048L
100533LD
60V
n
n
RT 2.3.060L
100532LD
110V
n
RT 2.3.110
100531
220V
n
RT 2.3.220
100530
PI
LED (red)
PI
PSS
LED (green)
RT 8-pin
300V AC
RT 11-pin, COMBI, KAPPA, PLUS
300V AC
10A
PF113BEM (ES 12)
180136
ES
RT 8-pin, COMBI
300V AC
10A
ES 9
180041
R11X
RT 11-pin, KAPPA, PLUS
300V AC
10A
R11X
180055
Nominal voltage
Art.No.
180139
Modules
for series
Nominal voltage
Type
Art.No.
ES 9, PF113BEM
6 - 24V AC/DC (+A1)
TYPE 61 (TVL 3)
180234
110 - 230V AC/DC (+A1)
TYPE 91 (TVL 4)
180235
6 - 230V DC (+A2)
TYPE 11 (TVD 2)
180231
6 - 230V DC (+A1)
TYPE 21 (TVD 1)
180230
6 - 24V DC (+A2)
TYPE 31 (TVL 2)
180233
6 - 24V DC (+A1)
TYPE 41 (TVL 1)
180232
RC-link
ES 9, PF113BEM
110 - 240V AC
TYPE 51 (TVR)
180236
Varistor
ES 9, PF113BEM
24V AC
TYPE 71 (TVV 1)
180237
230V AC
TYPE 81 (TVV 2)
180238
LED (green) + Diode
PSS
6 - 24V DC (+A1)
EM 12
180309
RC-link
PI
110 - 240V AC
M53
180264
PSS
110 - 230V AC
EM 03
180300
PI
24V AC
M71
180266
230V AC
M73
180267
24V AC
EM 04
180301
230V AC
EM 05
180302
Varistor
PSS
Varistor + LED (red)
PI
110 - 230V AC
M93G
180276
Resistor
PI
110 - 230V AC
M103
180269
Accessories
for Series
Type
Art.No.
Retaining Clip (plastic)
PI50
HB/RP 16
180029
PSS8/3
HB/PSS
180060
Front cover
PSS8/3
BS/PSS
180057
Relaysets
Socket
Contacts
Nominal
voltage
2 CO
AC
24V
n
DC
24V
n
PSS8/3
Accessories
Retaining
clip
Page 222
n
Relay sockets
n
LED+Diode ES 9, PF113BEM
RP 012-2
8A
100521
n
ES 9, PF113BEM
8A
24V DC
100521LD
max. current Type
pro contact
10A
PF083BE (ES 8)
Diode
12V DC
RT 1.3.230L
Relay sockets
LED
n
n
48V
for series
gold-coated contacts
8A
LED (red) + Diode
PF
SET RP
RT 1.3.230
n
n
Series
PI50BE3
PCB relays
Contacts
Pole
PSS8/3
RP 012-2
ES 50
ES50/3
for series
Type
Art.No.
PF083BE, PF113BEM, ES 9, R11X
HB/RT
180043
230V
LED/
Varistor
protection
diode
n
n
AC
LED
n
Art.No.
100686
100681
n
n
SET RP024+LD/FD+PSS8+HB
n
n
SET RP024+LD/FD+PI50BE+HB
100682
SET RP730+LD+PSS8+HB
100684
n
n
Type
SET RP524+LD+PSS8+HB
n
SET RP730+LD/ARISTOR+PI50BE3+HB 100688
other sets on request
w w w. tel e-o n l i n e. co m
Page 223
Switching Relays Series SKR
Coupling units Series ENYA
Interface Relays
Coupling relay
<
1 CO contact, max. 6A switching current
<
Rated coil voltage 24VAC/DC or 230V AC
<
Position indicator via LED
<
Width 6,2mm
<
Accessories: 20-way jumper link
SKR
STKR
Interface relays
<
Zoom voltage 24-240V AC/DC
<
1 CO or 2 CO contacts
<
Width 17,5mm or 35mm
<
Installation design
E1K 24-240VAC/DC
E3K 12-240VAC/DC
Art.No. (PQ1)
110700
111700
Art.No. (PQ10)
-
-
9008662006034
9008662006041
Type
Contacts
Nominal voltage
Type
Art.No.
1 CO contact
AC/DC
24V
SKR 524
180501
DC
24V
SKR 024
180500
AC
230V
SKR 730
180502
Set pluggable interface relays
Contacts
Nominal voltage
Type
Art.No.
1 CO contact
AC/DC
24V
STKR 524
180504
DC
24V
STKR 024
180503
AC
230V
STKR 730
180505
Replacement relays
EAN13-Code
Nominal voltage
for Series
Type
Art.No.
Controls
-
-
DC
24V
STKR 024, STKR 524
RM699V-3011-85-1024
100660
Indicators (LEDs)
R
R
DC
60V
STKR 730 (230V AC)
RM699V-3011-85-1060
100661
Functions
Coupling relays
Coupling relays
Isolation
Rated voltage 250V AC
Rated voltage 250V AC
III (in accordance with IEC 60664-1)
Rated voltage: 4kV
III (in accordance with IEC 60664-1)
Rated voltage: 4kV
Supply
24-240VAC/DC
terminals A1-A2
12-240VAC/DC
terminals A1-A2
Output
1 potential free change over contact
250V AC, 8A
2 potential free change over contact
250V AC, 8A
Width
17,5mm
35mm
CE
CE
Overvoltage cat.
Accessories
for Series
Type
Art.No.
Jumper link blue for 20 coupling units
SKR, STKR
PB-B SKR
180535
Jumper link red for 20 coupling units
SKR, STKR
PB-R SKR
180536
Certiicates
Mechanical
design
Terminal capacity
1 x 0.5 to 2.5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0.5 to 1.5mm² with/without multicore cable end
2 x 2.5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to +55°C • Storage temperature: -25 to +70°C • Transport temperature: -25 to +70°C • Relative humidity: 15% to 85%
(in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC 60664-1)
Accessories
Page 224
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-rail TS 35 according to EN 60715 • Mounting position: any • Shockproof
terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque: max. 1Nm
-
w w w. tel e-o n l i n e. co m
Page 225
Coupling units Series OCTO
Functions
E1K
Automatic-Manual-OFF relay
<
Three-way switch: Automatic, permanently OFF or ON
<
Checkback signal of the switch setting AUTO
<
1 CO contact
<
Width 17,5mm
<
Installation design
Connections
E3K
(+)
(+)
HAR1
Type
U~
U~
(-)
(-)
15
11 21
A1
A1
A1
15
R
A1
11
R
21
R
A2 16 18
A2 12 14 22 24
A2
16 18
A2
12 14 22 24
Art.No. (PQ1)
170010
Art.No. (PQ10)
900866200067
EAN13-Code
Function
Controls
Width 17,5mm
Dimensions
Width 35mm
Indicators (LEDs)
R
Functions
AUTO (automatic) • 0 (permanently OFF) • HAND (permanently ON)
Control input
control voltage for automatic operation
24V AC/DC
terminals A3-A2
45mm
87mm
87mm
45mm
Output
1 potential free CO contact
250V AC, 8A
Checkback
1 potential free NO contact for checkback signal of the switch setting AUTO
48V AC/DC; 500mA
terminals B1-B2
Supply
24V AC/DC
terminals A1-A2
Width
5mm
44mm
60mm
17,5mm
5mm
44mm
60mm
35mm
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 226
17,5mm
Certiicates
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC
60664-1)
-
w w w. tel e-o n l i n e. co m
Page 227
Automatic (AUTO)
The contact of checkback B1-B2 is closed.
When the signal voltage U is applied at terminal A3 the output relay R switches into on-position (yellow LD illuminated)
Coupling units Series OCTO
Functions
Analogue data encoder
Permanently OFF (0)
The contact of checkback B1-B2 is opened.
The output relay R remains in off-position independent from the connected signal voltage.
<
Analogue data encoder 0 to 10V DC (OVP1)
<
Analogue data encoder 0 to 20mA DC (OCP1)
Permanently ON (HAND)
The contact of checkback B1-B2 is opened.
When the supply voltage U is applied at terminal A1 the output relay R switches into on-position (yellow LED illuminated). Changes of the
signal voltage do not influence the state of the output relay.
<
Checkback signal of the switch setting AUTO
<
1 analogue output and 1 NO contact (checkback)
<
Width 17,5mm
<
Installation design
Connections
HAR1
Supply voltage (+)
Type
Signal voltage (+)
OVP1 24VAC/DC
OCP1 24VAC/DC
170018
Checkback
AUTO
A1 A2
B1 B2
11
12 14
11
A3
Art.No. (PQ1)
170012
12
14
Art.No. (PQ10)
-
-
900866200069
900866200075
EAN13-Code
Controls
Width 17,5mm
Dimensions
Indicators (LEDs)
Functions
Analogue input
Output
Checkback
Supply
Width
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 228
function • analogue data
function • analogue data
LED (intensity according to the value of the output signal)
LED (intensity according to the value of the output signal)
AUTO (output according to input YR)
0 (permanently OFF)
HAND (output according to set value (regulator)
AUTO (output according to input YR)
0 (permanently OFF)
HAND (output according to set value (regulator)
input for automatic operation
0 to 10V DC
terminals YR-GND
input for automatic operation
0 to 20mA DC
terminals YR-GND
1 analogue output
0 to 10V DC
terminals Y-GND
1 analogue output
0 to 20mA DC
terminals Y-GND
1 potential free NO contact for checkback signal of the switch setting
AUTO
28V AC/DC; 2A
terminals B1-B2
1 potential free NO contact for checkback signal of the switch setting
AUTO
28V AC/DC; 2A
terminals B1-B2
24V AC/DC
terminals A1-A2
24V AC/DC
terminals A1-A2
17,5mm
17,5mm
CE • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC
60664-1)
-
w w w. tel e-o n l i n e. co m
Page 229
OVP1
Automatic (AUTO): The contact of checkback B1-B2 is closed. The input signal applied to terminal YR is looped through unchanged to
terminal Y.
Permanently OFF (0): The contact of checkback B1-B2 is opened. No outputsignal at terminal Y.
Manual signal (HAND): The contact of checkback B1-B2 is opened. Output signal at terminal Y (0 to 10V DC) according to the value set
on the front mounted regulator.
OCP1
Automatic (AUTO): The contact of checkback B1-B2 is closed. The input signal applied to terminal YR is looped through unchanged to
terminal Y.
Permanently OFF (0): The contact of checkback B1-B2 is opened. No outputsignal at terminal Y.
Manual signal (HAND): The contact of checkback B1-B2 is opened. Output signal at terminal Y (0 to 20mA DC) according to the value set
on the front mounted regulator.
OVP1
24V
0V
0-20mA
<
Trigger 1 to 10V DC (OVL1)
<
Trigger 2 to 20mA DC (OCL1)
<
Checkback signal for switch setting AUTO
<
1 CO contact
<
Width 17,5mm
<
Installation design
OVL1 24VAC/DC
OCL1 24VAC/DC
Art.No. (PQ1)
170015
170017
Art.No. (PQ10)
-
-
900866200072
900866200074
Function • levelswitch
Function • levelswitch
Type
A1 A2
A1 A2
B1 B2
B1 B2
Output
0-10V
YR
Y
Potentiometer
Levelswitch
Connections
OCP1
24V
0V
0-10V
Coupling units Series OCTO
Functions
output signal
0-20mA
YR
Y
Potentiometer
GND
YR
GND
YR
GND
Y
GND
Y
EAN13-Code
Controls
Width 17,5mm
Dimensions
U•R
U•R
AUTO (output according to signal on YR)
0 (permanently OFF)
1 (permanently ON)
AUTO (output according to signal on YR)
0 (permanently OFF)
1 (permanently ON)
1 to 10V DC
2 to 20mA DC
input for automatic operation
0 to 10V DC
terminals YR-A2
input for automatic operation
0 to 20mA DC
terminals YR-A2
1 potential free NO contact for checkback signal of the switch setting
AUTO
28V AC/DC; 2A
terminals B1-B2
1 potential free NO contact for checkback signal of the switch setting
AUTO
28V AC/DC; 2A
terminals B1-B2
Supply
24V AC/DC
terminals A1-A2
24V AC/DC
terminals A1-A2
Output
1 potential free CO contact
250V AC, 8A
1 potential free CO contact
250V AC, 8A
Indicators (LEDs)
Functions
Trigger level
Analogue input
Checkback
Width
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 230
17,5mm
17,5mm
CE • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC
60664-1)
-
w w w. tel e-o n l i n e. co m
Page 231
OVL1
Automatic (AUTO): The contact of checkback B1-B2 is closed. The output relay R switches into on-position (yellow LED illuminated) when
the signal voltage applied at the terminals YR-A2 exceeds the the value adjusted at the regulator. The output relay switches into off-position
(yellow LED not illuminated) when the signal voltage falls below the set value by more than the ixed hysteresis.
Permanently OFF (0): The contact of checkback B1-B2 is opened. The output relay R remains in off-position (yellow LED not illuminated)
independent from the connected signal voltage.
Permanently ON (HAND): The contact of checkback B1-B2 is opened. When the supply voltage U is applied at terminal A1 the output
relay R switches into on-position (yellow LED illuminated). Changes of the signal voltage do not inluence the state of the output relay.
OCL1
Automatic (AUTO): The contact of checkback B1-B2 is closed. The output relay R switches into on-position (yellow LED illuminated) when
the signal voltage applied at the terminals YR-A2 exceeds the the value adjusted at the regulator. The output relay switches into off-position
(yellow LED not illuminated) when the signal voltage falls below the set value by more than the ixed hysteresis.
Permanently OFF (0): The contact of checkback B1-B2 is opened. The output relay R remains in off-position (yellow LED not illuminated)
independent from the connected signal voltage.
Permanently ON (HAND): The contact of checkback B1-B2 is opened. When the supply voltage U is applied at terminal A1 the output
relay R switches into on-position (yellow LED illuminated). Changes of the signal voltage do not inluence the state of the output relay.
OVL1
24V
0V
0-20mA
<
Diode gate with 10 inputs and one output
<
Combined alarm signal
<
Width 22,5mm
<
Plug-in mounting
TD1
TD2
Art.No. (PQ1)
2490000
2490001
Art.No. (PQ10)
-
-
9008662005846
9008662005853
-
-
Type
A1 A2
A1 A2
B1 B2
B1 B2
11
11
12 14
12 14
11 YR
11 YR
12
12
14
Array with ‚or‘ function
Connections
OCL1
24V
0V
0-10V
Diode gate Series TREND
Functions
14
EAN13-Code
Controls
Width 17,5mm
Dimensions
Indicators (LEDs)
-
-
logical function ‚OR‘
logical function ‚OR‘
Inputs
semiconductor elements: pins 2 to 11
10 diodes (types 1N4007)
anode is common
peak voltage: 1000V
forward voltage: approx. 0,8V
forward current per diode: 0,7A (single channel)
forward current per diode: 0,1A (all channels)
semiconductor elements: pins 2 to 11
10 diodes (types 1N4007)
cathode is common
peak voltage: 1000V
forward voltage: approx. 0,8V
forward current per diode: 0,7A (single channel)
forward current per diode: 0,1A (all channels)
Supply
-
-
Output
semiconductor element: pins 1
1 diodes (types 1N4007)
peak voltage: 1000V
forward voltage: approx. 0,8V
forward current: max. 1A
semiconductor element: pins 1
1 diodes (types 1N4007)
peak voltage: 1000V
forward voltage: approx. 0,8V
forward current: max. 1A
Width
22,5mm
22,5mm
CE • GOST
CE • GOST
Functions
Certiicates
Mechanical
design
Self-extinguishing plastic housing, IP rating IP40 • Connection and mounting by 11-pin socket in accordance with IEC 60067-1-18a (types
R11X or ES12) • Mounting position any
Ambient
conditions
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 3 (in accordance with IEC 60664-1)
Accessories
Page 232
Plug-in socket R11X or ES12
w w w. tel e-o n l i n e. co m
Page 233
TD1
Multicoupling relay
<
4-way coupling relay
<
PNP (KM2X04P-M) or NPN (KM2X04M-M) control
<
2 CO contacts, 2 NO contacts
<
Width 22,5mm
<
Industrial design
Connections
TD2
Input circuit
Coupling units Series VOX
Functions
Diode gate with 10 inputs and one output
Input circuit
KM2X04P-M 24VDC
KM2X04M-M 24VDC
Art.No. (PQ1)
423501
423502
Art.No. (PQ10)
-
-
900866200352
900866200356
Type
Output circuit
Output circuit
EAN13-Code
Controls
Width 22,5mm
Dimensions
R1 • R2 • R3 • R4
R1 • R2 • R3 • R4
coupling relay
coupling relay
Supply
24V DC
terminals A1-A5 (relay 1)
terminals A2-A5 (relay 2)
terminals A3-A5 (relay 3)
terminals A4-A5 (relay 4)
polarity: +24V as common on terminal A5
24V DC
terminals A1-A5 (relay 1)
terminals A2-A5 (relay 2)
terminals A3-A5 (relay 3)
terminals A4-A5 (relay 4)
polarity: GND (-) as common on terminal A5
Output
2 potential free CO contact; 250V AC, 8A
2 potential free NO contact; 250V AC, 8A
2 potential free CO contact; 250V AC, 8A
2 potential free NO contact; 250V AC, 8A
Indicators (LEDs)
Functions
Width
Certiicates
Mechanical
design
Terminal capacity
Ambient
conditions
Accessories
Page 234
22,5mm
22,5mm
CE • GOST
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient temperature: -25 to +55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC
60664-1)
-
w w w. tel e-o n l i n e. co m
Page 235
Semiconductor control
KM2X04P-M
Signal converter Series M1
Functions
Coupling relay with four independent circuits including galvanic separated output relays.
KM2X04M-M
Connections
Signalampliier
<
Separation and transformation of standard signals (M1MTB1; M1MTN1)
<
Uni- and bipolare industrial signals (M1MTB1)
<
Temperature signal converter for temperatures from -100 to +700°C (M1MPT100)
<
Applicable to PT100 and PT1000 probes
<
3-Port-separation with secure galvanic separation
<
Supply voltage by zoom voltage 24 to 240V AC/DC
<
1 output
<
Width 12,5mm
<
Industrial design
M1MTB1 24-240V
M1MTN1 24-240V
M1MPT100 24-240V
Art.No. (PQ1)
717002
717003
717004
Art.No. (PQ10)
-
-
-
Zero • Span
-
Zero • Span
U
U
U
Universal signal ampliier
Standard signal ampliier
Universal temperature signal ampliier
current input terminals 1-2:
±20mA • 0 to 20mA • 4 to 20mA • ±10mA • 0
to 10mA • 2 to 10mA
(input resistance 25Ohm)
current input terminals 1-2:
0 to 20mA • 4 to 20mA
(input resistance 22Ohm)
thermo couple input terminals 1 to 4:
probe: PT100 or PT1000
2-wire, 3-wire or 4-wire
measured range: -100°C to +700°C
probe current PT100: 1mA
probe current PT1000: 0,1mA
wiring impedance per wire: max. 10Ohm
sensor wire brake detection: yes
Type
EAN13-Code
Controls
Width 22,5mm
Dimensions
Indicators (LEDs)
Functions
Input circuit
voltage input terminals 3-4:
±10V • 0 to 10V • 2 to 10V • ±5V •
0 to 5V • 1 to 5V
(input resistance: approx. 1 Ohm)
current output terminals 5-6:
0 to 20mA • 4 to 20mA
(output voltage: max. 10V)
current output terminals 5-6:
0 to 20mA • 4 to 20mA
(output voltage: max. 10V)
voltage output terminals 5-6:
0 to 10V
(output current: max. 10mA)
voltage output terminals 5-6:
0 to 10V • 2 to 10V •
0 to 5V • 1 to 5V
(output current: max. 5mA)
3-way isolation:
secure galvanic separation up to 600V AC
(in accordance with DIN EN 61010 part 1)
overvoltage cat. II (4kV AC)
3-way isolation
overvoltage cat. II (2,5kV AC)
3-way isolation:
secure galvanic separation up to 300V AC/DC
(in accordance with DIN EN 61010 part 1)
overvoltage cat. II (2,5kV)
Supply
24 to 240V AC/DC
terminals 7-8
24 to 240V AC/DC
terminals 7-8
24 to 240V AC/DC
terminals 7-8
Width
12,5mm
12,5mm
12,5mm
CE • GOST
CE • GOST
CE • GOST
Output circuit
current output terminals 5-6:
±20mA • 0 to 20mA • 4 to 20mA • ±10mA • 0
to 10mA • 2 to 10mA
(output voltage: max. 12V)
voltage output terminals 5-6:
±10V • 0 to 10V • 2 to 10V • ±5V •
0 to 5V • 1 to 5V
(output current: max. 10mA)
Isolation
Certiicates
Mechanical
design
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -20 to 70°C • Storage temperature: -35 to +85°C • Transport temperature: -35 to +85°C • relative humidity: 15% to 85% •
Pollution degree: 2
Accessories
Page 236
voltage input terminals 3-4:
0 to 10V
(input resistance: approx. 1 Ohm)
-
w w w. tel e-o n l i n e. co m
Page 237
M1MTB1 24-24V M1MTN1 24-240V M1MPT100 24-240V
Zero
Eingang
Span
Eingang
I +U +-
1
2
3
4
Ausgang
+
U/I
6 -
5
U/I
Grenzfrequenz:
>10kHz
30Hz
U
=
I +U +-
Ausgang
Zero
1
2
+
U/I
6 -
U
Ausgang
3
1
J
J
=
=
7
8
+
U/I
6 -
M1MTB1 24-240V
7
8
8
5
6
U
OUT
1
2
3
4
<
Width 12,5mm
<
Industrial design
Type
M1MTNI
Art.No. (PQ1)
717005
Output
8
5
6
U
OUT
J
IN
1
3
voltage +
input
Art.No. (PQ10)
2
4
EAN13-Code
-
Controls
Do not operate inputs for voltage and current simultaneously!
M1MTN1 24-240V with current input
2-channels with secure galvanic seperation; test voltage 4 kV ~
7
8
+
-
Output
+ current
- input
<
Connections
7
IN
No power supply signal required
Versorgungsspannung
20 to 253V AC/DC
0V
20 to 253V AC/DC
0V
7
<
=
=
M1MPT100 24-240V
+
-
Seperation of 0(4)...20mA Standard Signals
2-Leiter 3-Leiter 4-Leiter
Versorgungsspannung
Versorgungsspannung
<
5
J
2
4
=
Loop-Powered Isolator
Span
5
U/I
3
4
Signal converter Series M1
Block diagram
Connections
M1MTN1 24-240V with voltage input
-
Indicators (LEDs)
-
Functions
Loop-Powered Isolator
Input circuit
20 to 253V AC/DC
0V
current input terminals 1-2, 3-4
4 to 20mA / max. 30V
operating current: < 20 µA
overload: ≤ 100 mA, ≤ 30V
20 bis 253V AC/DC
0V
+
-
+
-
output
7
8
7
5
6
5
6
U
OUT
U
OUT
IN
8
2
1
2
3
4
3
4
+
106mm
5mm
12.5mm
-
Width
12,5mm
Mechanical
design
+
Input
Dimensions
Width 12,5mm
Supply
Certiicates
0-10V
input
working voltage: ( basic insulation)
up to 600V AC/DC for overvoltage category II (4kV AC), (accord. DIN EN 61010-1)
Isolation
IN
1
0-10V
current output terminals 5-6, 7-8
4 to 20mA / max. 28V
response time: approx. 5ms at 500 Ω load
ripple: < 10 mVeff
Output circuit
Output
CE • GOST
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -20 to 70°C • Storage temperature: -35 to +85°C • Transport temperature: -35 to +85°C • relative humidity: 15% to 85% •
Pollution degree: 2
Accessories
-
99mm
Page 238
w w w. tel e-o n l i n e. co m
Page 239
Mains decoupler Series OCTO
M1MTNI
Block diagram
<
All-pole disconnection
<
Automatic operation
<
Automatic off (manual on for test purpose)
<
up to 1000W lamp load
<
Minimised DC test voltage in switched off state (200 to 250mV)
<
Width 35mm
<
Installation design
Connections
M1MTNI
Current
output I2
+
+
7
8
5
6
ONF3 230V AC
Type
Current
output I1
OUT1 OUT2
IN1
1
2
3
4
+ Current
- input I1
Art.No. (PQ1)
+
-
Current
input I2
IN2
2330900
Art.No. (PQ10)
Do not operate inputs for voltage and current simultaneously!
900866200126
EAN13-Code
Measured variable
Width 12,5mm
Dimensions
Detection of no load condition
5 to 200mA (Activation current ION)
for adaption to charcteristic of connected loads
Adjustable range
ixed, approx. 70% of adjusted activation current
Release current
Test voltage
200 to 250mV DC monitoring voltage at disconnected mains
ION • Function
Controls
U•R
Indicators (LEDs)
Functions
1: Automatic operation (automated disconnected mains at no load condition)
0: manual ON for test purpose
ixed, approx. 6s
Tripping delay
ixed, approx. 0,5s
Rise time
Supply
230V AC
terminals L-N
Output
2 NO contacts
250V, 16A AC
Width
35mm
Certiicates
Mechanical
design
Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position any •
Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 • Tightening torque max. 1Nm
Terminal capacity
1 x 0,5 to 2,5mm² with/without multicore cable end • 1 x 4mm² without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end
• 2 x 2,5mm² lexible without multicore cable end
Ambient
conditions
Ambient temperature: -25 to 55°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to
+70°C • relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC
60664-1)
Accessories
Page 240
CE • GOST
Ballast GLE-ONF
w w w. tel e-o n l i n e. co m
Page 241
0
I
Automatic OFF
Automatic ON
Safety relays Series S2
Functions
Modul system
<
Monitoring of emergency OFF and two-handed equipment
<
Monitoring of protective doors, light barriers and photoelectric beams
<
One- or two-channel control
<
Contact extentions, delayed or instantaneous switching
<
Stop categorie 0 or 1
<
Width 22,5mm
Connections
ONF3
Load 230V~
Emergency
OFF relay
Safety relays
Supply voltage
Applications
24V AC
n
n
n
24V DC
n
n
n
115 - 120V AC
a.A.
230V AC
a.A.
n
n
n
n
n
n
n
n
n
n
a.A.
a.A.
a.A.
n
a.A.
a.A.
a.A.
Maximum Achievable Safety-Category
4
4
4
4/3
4
4
2
4
4
4
4
Stop-Category
0
0
0
0/1
0
0
0
0
1
0
0
Emergency Stop
n
n
n
n
n
n
n
n
Safety Gate
n
n
n
n
n
n
n
n
n
Safety Mat
n
OSSD (light grill)
n
Monitoring of Valve-State
supply network
n
n
n
Two-Channel Activation
n
Contact Expansion Without Delay
n
Contact Expansion With Delay
Reset
Width 35mm
Dimensions
Input Circuit
n
Automatic Start
n
n
n
n
n
Start with Reset Monitoring
n
n
n
n
n
Start without Reset Monitoring
n
n
n
n
n
Synchronous Time Check Selectable
n
n
n
n
n
Cross Monitoring
n
n
n
n
n
n
Actuation via Semic. Output (OSSD) poss.
n
n
n
n
n
Input Debouncing
Output Circiut
n
n
n
n
n
n
n
0
0
0
1
0
0
0
0
4
0
0
Enabling current Path without Delay
3
2
2
2
3
2
3
4
0
3
3
Signalling current Paths
0
1
1
0
0
1
1
3
3
1
1
n
n
n
n
n
n
n
n
22,5mm
n
n
n
n
S2NGS021 24V AC/DC
S2NG021 24V AC/DC
S2NGR120 3S 24V DC
S2LST030 24V AC/DC
S2Z021 24V AC/DC
S2NT031 24V AC/DC
S2K043 24V AC/DC
S2KR403 3S 24V DC
ZK31X45 24V DC
ZK31X45 230V AC
588815
588814
588816
588823
588818
588811
588821
588822
588000
588033
Art.No.
S2NT030 24V AC/DC
Type
588826
45mm
Serie S2
Page 242
n
n
Delayed Enabling Current Path
Delayed reset
Width
n
Serie ZK
w w w. tel e-o n l i n e. co m
Page 243
Hour Meters Series TBG and TBW
Time Switches Series TSC
DIN rail mounting and front panel mounting
< < Daily-, weekly- or yearly program
<
AC powered devices syncronised by mains frequency or quarz stabilized
< < Automatic summertime change over
<
DC powered devices quarz stabilised
< Astro function (TSC28.23)
<
Capacity up to max. 999.999h
< < Unrestricted block-programming
<
Indication of operation mechanical or by lashing LED
< < Up to 4 CO contacts
<
DIN rail mounting or front panel mounting
< < DIN rail mounting and front panel mounting
DIN rail mounting
Mains
voltage
AC
230V
Hour meters
Channels CO
1
230V
Switching
Astro function capacity
1
1
230V
Contacts
NO
1
2
2
2
2
2
2
4
3
n
1
Rated con- Dimension
sumption H x B x T [mm]
Series
Type
Art.No.
4000VA
1,5VA
90 x 35,8 x 60
TSC28.11 pro 230VAC
711142
4000VA
1,5VA
90 x 35,8 x 60
TSC18.10 pro 230VAC
711144
4000VA
1,5VA
90 x 35,8 x 60
TSC28.21 pro 230VAC
711143
4000VA
1,5VA
90 x 35,8 x 60
TSC28.23 pro 230VAC
711147
2500VA
2VA
120 x 71,5 x 60 TSC98.20 pro 230VAC
711132
2500VA
2VA
120 x 71,5 x 60 TSC98.40 pro 230VAC
711131
TBG
TBW
Rated fre- Supply
voltage
quency
DC 12 - 48V
50Hz
AC
Front panel mounting
Mains
voltage
AC
Channels CO
Outputs
NO
Switching
Astro function capacity
Rated con- Dimension
sumption H x B x T [mm]
Type
Art.No.
24V
1
1
4000VA
0,9VA
94,5 x 72 x 53
TSC44.12 24VAC
711676
115V
1
1
4000VA
2,8VA
94,5 x 72 x 53
TSC44.12 115VAC
711576
230V
1
1
4000VA
1,5VA
94,5 x 72 x 53
TSC44.12 230VAC
711578
24V
2
1
1
4000VA
1,3VA
94,5 x 72 x 53
TSC44.22 24VAC
711679
230V
2
1
1
4000VA
1,5VA
94,5 x 72 x 53
TSC44.22 230VAC
711579
50/60Hz
AC
Counting
capacity
999 999h
Accuracy of Dimension
reading
H x B x T [mm]
0,1h
28,2 x 53,2 x 63
Type
Art.No.
TBG30.18 12-48VDC
711056
48 x 48 x 38
TBG40.17 12-48VDC
711025
TBG70.18 12-48VDC
711435
711408
99 999h
0,1h
85 x 17,5 x 61,5
90 x 35 x 60
TBG70.29 12-48VDC
24V
99 999h
0,01h
45 x 48 x 38
TBW40.18 24VAC 50Hz
711045
115V
99 999h
0,01h
45 x 48 x 38
TBW40.18 115VAC 50Hz
711042
45 x 48 x 38
TBW70.18 115VAC 50Hz
711434
230V
99 999h
0,01h
28,2 x 53,2 x 63
TBW30.18 230VAC 50Hz
711050
45 x 48 x 38
TBW40.18 230VAC 50Hz
711040
45 x 48 x 38
TBW70.18 230VAC 50Hz
711430
90 x 35 x 60
TBW70.29 24VAC 50/60Hz
711355
24V
99 999h
0,1h
48V
99 999h
0,1h
105 x 35 x 60
TBW70.89 48VAC 50/60Hz
711139
115V
99 999h
0,1h
105 x 35 x 60
TBW70.89 115VAC 50/60Hz
711140
230V
99 999h
0,1h
105 x 35 x 60
TBW70.89 230VAC 50/60Hz
711141
90 x 35 x 60
TBW70.29 230VAC 50/60Hz
711350
Accessories
TSC28
Page 244
TSC44
TSC98
Type
Art.No.
Tension bracket for TBG/TBW30
SB-TBX30
711809
Shutter for TBG/TBW40 (55x55mm)
B55-TBX40
711800
Screen for TBG/TBW40 (72x72mm)
ME72-TBX40
711801
Retaining clip for TBG/TBW40
SB-TBX40
711807
Sealing ring for TBW40 (IP54)
DR-TBW40
711813
Terminal cover for TBG/TBW70.29 (sealable)
KA-TBX70.29
711812
TBG/TBW 30.x
TBG/TBW 40.x
w w w. tel e-o n l i n e. co m
TBG/TBW 70.18
TBG/TBW 70.29
TBW 70.89
Page 245
DC Power Supplies Series RNG and RNG-I
DC power supply TELE VIP
Transformers
Switching power supply
< < Low residual ripple
<
DIN rail mounting
< < Integrated thermo protection
<
Overload and short circuit protection
< < Self cooling
<
Industrial housing for the switching cabinet and plant construction
< < Sealed-in
<
Valued Industrial Partner, Chinfa
Regulated power supply unit
Power supply
Primary voltage
Contacts
unregulated
1
2
U
AC
AC
230V
230V
Secondary
I
P
DC 24V 1,5A
DC 24V 3A
5A
10A
400V
DC 24V 3A
5A
1
AC
Dimension
H x B x T [mm]
Weight
Type
Art.No.
18W
120 x 78 x 96
1,6kg
RNG 36/12-230
490508
Secondary
1-phase
U
DC
5V
P
5W
I
1A
[%]
69
10W
2A
73
Primary
voltage
Dimension
H x B x T [mm]
Type
Art.No.
90 x 22,5 x 115
DRA05-05A
491410
90 x 22,5 x 115
DRA10-05A
491411
72VA
20W
133 x 85 x 105
2,1kg
RNG 72-230
490510
15W
3A
75
491412
133 x 85 x 105
DRA18-05A
120VA
28W
90 x 22,5 x 115
2,9kg
RNG 120-230
490515
30W
6A
77
90 x 40,5 x 115
DRAN30-05A
491576
491413
240VA
48W
172 x 170 x 109
6,1kg
RNG 240-230
490520
72VA
20W
133 x 85 x 105
2,1kg
RNG 72-400
490511
120VA
28W
133 x 85 x 105
2,9kg
RNG 120-400
60W
10A
79
90 x 40,5 x 115
DRAN60-05A
5W
0,4A
72
90 x 22,5 x 115
DRA05-12A
491418
490516
10W
0,8A
75
90 x 22,5 x 115
DRA10-12A
491419
12V
240VA
48W
172 x 170 x 109
6,1kg
RNG 240-400
490519
1,5A
77
90 x 22,5 x 115
DRA18-12A
491422
DC 24V 1,5A
36VA
16W
120 x 78 x 96
18W
230V
1,6kg
RNG 36-230
490505
30W
2,5A
90 x 40,5 x 115
DRAN30-12A
491572
400V
DC 24V 1,5A
36VA
16W
120 x 78 x 96
82
1,6kg
RNG 36-400
490506
60W
5A
84
90 x 40,5 x 115
DRAN60-12A
491587
120W
10A
84
124,5 x 64 x 123,6
DRAN120-12A
491568
5W
0,3A
72
90 x 22,5 x 115
DRA05-15A
491415
10W
0,7A
76
90 x 22,5 x 115
DRA10-15A
491414
18W
1,2A
77
90 x 22,5 x 115
DRA18-15A
491416
5W
0,2A
72
90 x 22,5 x 115
DRA05-24A
491420
10W
0,4A
76
90 x 22,5 x 115
DRA10-24A
491424
18W
0,8A
77
90 x 22,5 x 115
DRA18-24A
491425
30W
1,25A
83
90 x 40,5 x 115
DRAN30-24A
491476
60W
2,5A
86
90 x 40,5 x 115
DRAN60-24A
491575
120W
5A
86
124,5 x 64 x 123,6
DRAN120-24A
491595
240W
10A
89
124,5 x 83,5 x 123,6
DRA240-24A
491571
480W
20A
89
124,5 x 175,5 x 123,6
DRA480-24A
491577
Dimension
H x B x T [mm]
Type
Art.No.
90 x 40,5 x 115
DRAN30-24A*
491476BU
90 x 40,5 x 115
DRAN60-24A*
491575BU
124,5 x 64 x 123,6
DRAN120-24A*
491569BU
124,5 x 83,5 x 123,6
DRAN240-24A*
491571BU
DRAN480-24A*
491577BU
10A
U-limited
36VA
Power
loss
15V
Accessories
Dimension
H x B [mm]
Type
Art.No.
Mounting clip for RNG 36
120 x 66
MP-RNG 36
490593
Mounting clip for RNG 72
132 x 70
MP-RNG 72
490594
Mounting clip for RNG 120
132 x 83
MP-RNG 120
490592
24V
90 - 265V AC
120 - 375V DC
Power supply unit with total discharge protection for back-up system
(e.g. storage batteries)
Secondary
1-phase
Page 246
U
DC
27,2V
Primary
voltage
I
1,1A
P
30W
[%]
86
2,2A
60W
89
4,4A
120W
86
8,8A
240W
90
17,6A
480W
90
124,5 x 175,5 x 123,6
A
B
90 - 264V AC
120 - 375V DC
w w w. tel e-o n l i n e. co m
Page 247
DC power supply TELE VIP
Switching power supply
<
DIN rail mounting
<
Overload and short circuit protection
<
Industrial housing for the switching cabinet and plant construction
<
Installation design for distribution and plant construction
<
Valued Industrial Partner, Meanwell
ACCESSORIES
Regulated power supply unit
U
1-phase
DC
Secondary
P
12V
15V
24V
Page
[%]
I
24W
42W
54W
75W
120W
42W
36W
48W
60W
75W
120W
2A
3,5A
4,5A
6,3A
10A
2,8A
1,5A
2A
2,5A
3,2A
5A
81
77
82
76
80
77
83
80
84
81
84
240W
10A
84
480W
20A
89
2-phase
DC
24V
120W
5A
85
3-phase
DC
24V
240W
480W
960W
240W
480W
10A
20A
40A
5A
10A
89
89
91
89
90
24V
48V
Primary
voltage
90 - 264V AC
120 - 370V DC
90 - 264V AC
248 - 370V DC
85 - 264V AC
120 - 370V DC
180 - 264V AC
250 - 370V DC
340 - 550V AC
480 - 780V DC
340 - 550V AC
480 - 780V DC
Dimension
H x B x T [mm]
Type
Art.No.
93 x 78 x 56
93 x 78 x 67
93 x 78 x 56
125,2 x 55,5 x 100
125,2 x 65,5 x 100
93 x 78 x 67
93 x 78 x 56
93 x 78 x 67
93 x 78 x 56
125,2 x 55,5 x 100
125,2 x 65,5 x 100
DR-30-12 1)
DR-4512
DR-60-12 1)
DR-75-12
DR-120-12
DR-4515
DR-30-24 1)
DR-4524
DR-60-24 1)
DR-75-24
DR-120-24
491620
491607
491622
491608
491602
491609
491623
491611
491621
491612
491603
125 x 175 x 123
DRP-240-24 2)
491605
125,2 x 227 x 100
DRP-480-24 2)
491606
125,2 x 65,5 x 100
DRH-120-24
491604
125,2 x 125,5 x 100
125,2 x 227 x 100
125,2 x 276 x 100
125,2 x 125,5 x 100
125,2 x 227 x 100
DRT-240-24
DRT-480-24
DRT-960-24
DRT-240-48
DRT-480-48
491590
491613
491614
491615
491616
Power Modules,
Power Supply
Power Modules: TR2 and TR3
Power Supply: SNT
250
250
Level sensor
Level sensor: SK
251
Current transformers
Baffle-type current transformer: WSW
Bar-type current transformer: DSW
252
252
Others
- Base load component: GLE
- Mounting clip: MP
- Protection cover: GAMMA
- Remote potentiometer: RONDO
253
253
253
253
1) Installation design
2) Power Factor Correction
Industrial design
Page 248
Installation design
w w w. tel e-o n l i n e. co m
Page 249
Level sensors Series SK
Power Modules - Series TR and Power Supply - Series SNT
< < Plug-in module for internal power supply
< For monitoring relays, load monitors and timers (series GAMMA, TREND)
<
Probe for monitoring level of conductive liquids
<
Stainless levelprobes, PVC covered, IP rating IP44
< < Mounting by plug-in system in prepared slot of compatible units (no tools required)
< < Powermodules, providing galvanic separation between input and output circuit
< Sealed self-extinguishing plastic houseing. IP-rating IP40 (if mounted)
PowerModule
Level sensor
Series
Wattage
Mains voltage
Type
Art.No.
TR2
2VA
AC
12V
TR2 - 12V AC
282121
Suspensible sensor (immersion electrode)
50/60Hz
24V
TR2 - 24V AC
282110
Wand sensor
42V
TR2 - 42V AC
282111
48V
TR2 - 48V AC
282112
110V
TR2 - 110V AC
282113
127V
TR2 - 127V AC
282114
230V
TR2 - 230V AC
282120
400V
TR2 - 400V AC
282117
440V
TR2 - 440V AC
282119
12V
TR3 - 12V AC
285021
24V
TR3 - 24V AC
285010
42V
TR3 - 42V AC
285011
48V
TR3 - 48V AC
285012
110V
TR3 - 110V AC
285013
230V
TR3 - 230V AC
285025
400V
TR3 - 400V AC
285017
440V
TR3 - 440V AC
285019
500V
TR3 - 500V AC
285026
Art.No.
SK1
190107
2
500mm
90°
SK2
190108
3
500mm
90°
SK3-500
190109
3
1000mm
90°
SK3-1000
190110
SK1
SK2
SK3
21mm
2
Radius R1"
1
3
55mm
40mm
Radius R1"
75mm
2
20mm
1
55mm
40mm
Switching power supply
Series
Supply voltage
Type
Art.No.
SNT
DC
SNT2 24V DC
282050
24V
TR2
SNT2
35mm
35mm
Type
60°
ca.140mm
50/60Hz
Max.Temp.
on site
75mm
AC
Length
20mm
4VA
TR3
Number of electrodes
5mm
5mm
TR3
16mm
32mm
16mm
32mm
5mm
Page 250
26mm
5mm
w w w. tel e-o n l i n e. co m
Page 251
Current Transformers Series WSW and DSW
Accessories
Bafle-type and bar-type current transformers
Base load component GLE • Mounting clip • Protection cover • Remote potentiometer
< < Bafle-type current transformer (WSW 60)
Base load component GLE
< < Bar-typ current transformers (DSW 60 and DSW 80)
< < Integrated sealable terminal covers
< < DIN rail mounting clip optional
WSW
DSW
<
Function
Base load element for TELE mains decoupler.
The base load element is connected in parallel to electronic loads to ensure
that the mains decoupler can detect the switching on of the depending circuit.
After the decoupler has reconnected the circuit to the supplying power
network, the base load element warms up and changes from low-impendance
to high-impedance (PTC-resistor).
L1
N
PE
Netzfreischalter
ONF3, CNF3
Mechanical design
Silicone covered PTC-resistor with connection wires for built-in applications.
Ambient conditions
Ambient temperature: -25 to +55°C • Storage temperature: -25 to +70°C •
Transport temperature: -25 to +70°C • relative humidity: 15% to 85%
Montage
The base load element has to be connected in parallel to the load.
Bafle-type current transformers
Rated power
Class 1
2,5VA
Primary rated current
Type
1A
Dimension
H x B x T [mm]
80 x 60 x 30
WSW 60 1A/5A 2,5VA
498060
2,5A
80 x 60 x 30
WSW 60 2,5A/5A 2,5VA
498061
Art.No.
5A
80 x 60 x 30
WSW 60 5A/5A 2,5VA
498062
10A
80 x 60 x 30
WSW 60 10A/5A 2,5VA
498063
15A
80 x 60 x 30
WSW 60 15A/5A 2,5VA
498064
20A
80 x 60 x 30
WSW 60 20A/5A 2,5VA
498065
25A
80 x 60 x 30
WSW 60 25A/5A 2,5VA
498066
30A
80 x 60 x 30
WSW 60 30A/5A 2,5VA
498067
40A
80 x 60 x 30
WSW 60 40A/5A 2,5VA
498068
Mounting clip MP
Function
Mounting plate for fixing TELE devices on a mounting plate or wall.
<
Class 1
Primary rated current
1,25VA
60A
Dimension
H x B x T [mm]
33 x 33 x 50
2,5VA
100A
33 x 33 x 50
125A
33 x 33 x 50
DSW 60 125A/5A 2,5VA
498074
3,75VA
150A
33 x 33 x 50
DSW 60 150A/5A 3,75VA
498075
5VA
10VA
Type
DSW 60 60A/5A 1,25VA
498070
DSW 60 100A/5A 2,5VA
498073
Art.No.
200A
33 x 33 x 50
DSW 60 200A/5A 5VA
498076
250A
33 x 33 x 50
DSW 60 250A/5A 5VA
498077
300A
33 x 33 x 50
DSW 60 300A/5A 5VA
498078
400A
50,5 x 50,5 x 85
DSW 80 400A/5A
498081
500A
50,5 x 50,5 x 85
DSW 80 500A/5A
498085
600A
50,5 x 50,5 x 85
DSW 80 600A/5A
498082
750A
50,5 x 50,5 x 85
DSW 80 750A/5A
498080
800A
50,5 x 50,5 x 85
DSW 80 800A/5A
498084
1000A
50,5 x 50,5 x 85
DSW 80 1000A/5A
498079
1250A
50,5 x 50,5 x 85
DSW 80 1250A/5A
498083
Mechanical design
Self-extinguishing plastic, three drillholes diameter 4mm.
MP
MP Gamma
Bar-type current transformer
Rated power
GLE
Mounting clip
Mounting clip Series Gamma
Art.No. 075474
Art.No. 075574
Protection cover GAMMA
Function
Sealable front cover for series GAMMA
<
Mechanical design
Plastic cover
FA-G2 (IPS 22,5)
Front cover Gamma 22,5
Art.No. 070160
1500A
Class 3
1,25VA
50A
50,5 x 50,5 x 85
DSW 60 50A/5A 1,25VA
498069
2,5VA
75A
50,5 x 50,5 x 85
DSW 60 75A/5A 2,5VA
498071
80A
50,5 x 50,5 x 85
DSW 60 80A/5A 2,5VA
498072
Type
Art.No.
MC-SW (2 piece)
498100
Accessories
Mounting clip (2 piece) for DSW and WSW
Remote potentiometer RONDO R2
Remote potentiometer for front panel mounting. With the remote potentiometer
time values can be adjusted from a distance.
<
Maximum adjustment value:
1MΩ
(R2 1MΩ 0.1)
1MΩ
(R2 1MΩ 0.3)
Connections:
1
2
3
Base accuracy:
±10%
Repetition accuracy: ≤0,01%
R2 1MOHM 0,1
R2 1MOHM 0,3
R20 10KOHM
Page 252
scale 0.1 to 1
scale 0.3 to 3
First
Wiper
Finish
(of maximum scale value)
Remote potentiometer, scale 0,1-1
Remote potentiometer, scale 0,3-3
Remote potentiometer, scale 1-10
Art.No. 282130
Art.No. 282133
Art.No. 282131
Page 253
G2UI1 300V
165
D6M 12-240VAC/DC
121
G2PI1 480V
167
D6DM 24VAC/DC 110-240VAC
121
G2PI1 400V
167
6. Switching relays & further
automation components
D6DQ 24VAC/DC 110-240VAC
121
G2YI3 60mV
169
Switching relays
D6DE 24VAC/DC 110VAC
123
G2II1 5A
171
Miniature relays (RA, RM)
220
221
DELTA
INDEX
123
G2II1 10A
171
Relaysets
D6DET 4MIN 12-240VAC/DC
123
G2JI1 5A
173
Industrial relays (RT)
222
D6DET 40MIN 12-240VAC/DC
123
G2JI1 1A
173
Print relays (RP)
223
224
D6DE 24VDC/DC 230VAC
1. Sensing & Monitoring relays
S.
GAMMA
G2TFKN02 24-240V
43
E1YU400V01
69
G2TF01
45
E3YF400FAL02
71
G2TF01 230VAC
45
E1PF480Y/277VSY10
73
G2TF02 110VAC
45
E1PF400VSY01
73
D6DR 24VAC/DC 110VAC
125
G2BI1 400V12A
175
Interface relays (SKR)
D6DR 24VAC/DC 230VAC
125
G2CI1 400V12A
177
Coupling units
D6A 3MIN 24-240VAC/DC
125
G2TI4 PT
179
E1K 24-240VAC/DC
225
D6A 10MIN 24-240VAC/DC
125
G2DI4 24V
181
E3K 12-240VAC/DC
225
D6DI 24VAC/DC 110-240VAC
127
G2DI4 230V
181
OCTO
227
181
HAR1
227
D6DS 24VAC/DC 110-240VAC
129
G4PM690VSYL20
17
G2TF02 230VAC
45
E3PF400VSY02
73
G4PM500VSYL20
17
G2LM20 24VAC
47
E1UM230V01
75
G2PM400VSY20 24-240V
17
G2LM20 110VAC
47
E1UU230V01
75
G2PM400VSY20
17
G2LM20 230VAC
47
E1IM10AACL10
77
G2PM400VSY10
17
TREND
E3IM10AL20
77
G2PM115VSY20 24-240V
19
TPW400VN4X
49
E1IU5AAC01
77
G2PM230VSY20 24-240V
19
TPW115VSN4X
49
E1IU500mAAC01
77
G2PM230VSY10
19
TPW230VSN4X
49
E3TF01
79
G2PM115VSY10
19
TPW400VSN4X
49
E3LM10
81
G2PW400V10
19
TPF230VS4X
51
G2PU690VS20
21
TPF400VS4X
51
2. Loadmonitors
G2PU400VSY10 230VAC
21
TUW4X
53
GAMMA
G2YM400VL20
23
TUH4X
53
G4BM690V16ATL20
89
G2PF400VS02
25
TIW4X
55
G4BM690V16AL20
89
G2PF230VS02
25
TIH4X
55
G4BM480V12ADTL20 24-240V
91
G2PF115VS02
25
TIF30-300mAAC4X
55
G4BM480V12ADTL20
91
G2FW400VL20 24-240V
27
TDT4X
57
G4BM480V12AFTL20
93
G2UM300VL20
29
TT2X 24VAC
57
G4BM480V12ATL20
93
G2UM500VL10 230V
29
TT2X 230VAC
57
G2BM480V12AFL10
95
G2UM300VL20 24-240V
29
TLH4X 24VAC
59
G2BM400V12AL10
95
G2UW300V10
31
TLH4X 230VAC
59
G2BM400V12AFL10
95
G2UM10VL20 24-240V AC/DC
31
TLC4X 230VAC
59
G2BA480V12A 4...20mA
97
G2UM300VL10
31
KAPPA
G2IA5A 4...20mA
99
G2IM10AL10
33
K3UM230VAC02
61
G2CM400V10AL20
101
G2IM5AL20 24-240V
33
K3UM24VDC02
61
G2CM400V2AL20
101
G2IM10AL20
33
K3IM5AACL20 230V
61
G2CU400V10AL10
101
G2IM10AL20 24-240V
33
K3PF400VSY02
61
G2IM2AL20 24-240V
35
K3YM400VSY20
61
G2IM5AL10
35
ENYA
G2IM5AL20
35
E3YF400V02 0.85
63
G2ZMF11 24-240VAC/DC
111
G2IO5A10
37
E3YF400VT02 HTV 0.85
63
G2ZMF11
111
G2IO10A10
37
E3YF400VT02 0.85
63
G2ZM20 12-240VAC/DC
111
G2IU5A10
37
E3YF400VE20 0.85
63
G2ZA20 10min 24-240VAC/DC
113
G2IU10A10
37
E1YF400V01 0.85
65
G2ZA20 10min
113
G2JM5AL20
39
E1YF400V01 0.70
65
G2ZIF20 24-240VAC/DC
115
G2JM5AL20 24-240V
39
E1YF400VT01 0.85
65
G2ZIF20
115
G2TMPT100L20 24-240V
41
E3YM230VS20
67
G2ZI20 12-240VAC/DC
115
4. Monitoring systems and
Compact control units
G2TFKN02
43
E1YM480Y/277VS10
67
G2ZE10 400VAC
117
WatchDog pro
G2TF02
43
E1YM400VS10
67
G2ZS20 24-240VAC/DC
119
G4WDCU MMC
163
G2TF02 24-240V
43
E3YU400V02
69
G2ZS20
119
G2UI1 10V
165
Page 254
S.
G2DI4 PTCK
183
OVP1 24VAC/DC
229
131
G2DI8 24V
185
OCP1 24VAC/DC
229
K3ZM20P 12-240V AC/DC
131
G2DO4 R
187
OVL1 24VAC/DC
231
K3ZA20 24-240V AC/DC
131
G2DO4 SP24VDC
187
OCL1 24VAC/DC
231
233
K3ZI20 12-240VAC/DC
131
G2DO4 SN24VDC
187
TREND
K3ZS20 12-240VAC/DC
131
G2DO8 SPC24VDC
189
TD1
233
G2AM4 M
191
TD2
233
235
PLUS
PDM20F 24VAC/DC 110-240VAC
133
G2FBC MB-RTU
193
VOX
PDM11 24VAC/DC 110-240VAC
133
G2FBC MB-TCP
193
KM2X04P-M 24VDC
235
PDI20F 24VAC/DC 110-240VAC
133
G2FBC PB-DPV1
193
KM2X04M-M 240VDC
235
G2WDGW2 MB-RTU
195
Signal converter
G2WDGW2 MB-TCP
195
M1MTB1 24-240V
237
237
ENYA
E1ZM10 12-240VAC/DC
S.
GAMMA
G2DI4 SC
K3ZM20 12-240VAC/DC
KAPPA
135
E1ZM10 24-240VAC/DC
135
G2WDGW2 PB-DVP1
195
M1MTN1 24-240V
E3ZM20 12-240VAC/DC
135
G2RBC
197
M1MPT100 24-240V
237
E1ZMQ10 24-240VAC/DC
135
ECO
M1MTNI
239
E1ZMW10 24-240VAC/DC
135
ECO 8 III SYS
201
Safety relays
E1Z1E10 24-240V AC/DC
137
ECO 8 III GATE
201
S2
243
E1Z1R10 24-240V AC/DC
137
STEP-T
ZK
243
E1Z1ER10 24-240V AC/DC
137
STEP-T8 110VAC
203
Digital time switches
E1ZI10 12-240VAC/DC
139
STEP-T8 230VAC
203
TSCx8 DIN rail mounting
244
TSC44 Front panel mounting
244
E3ZI20 12-240VAC/DC
139
GAMMA
E3ZS20 12-240VAC/DC
141
G2ASMA20
E1ZTPNC 230VAC
143
TBG
245
E1ZTP 230VAC
143
5. Power electronics
TBW
245
E1ZWI
143
Softstarter
E1ZNT 230V AC
145
TSG
205
S.
Hour meters
DC power supply
210
Transformers (RNG)
246
Switching power supply
247
MSG
210
FSM10 24V AC/DC
147
EUROSTART
211
FSM10 100-240V AC
147
ESG
212
7. Accessories
AUCOM
213
Power modules (TR2, TR3)
FRONT
3. Time relays
S.
COMBI
COM3TP 24-240V AC/DC
149
RONDO
MBG
214
Probes (SK)
214
Current transfomer (WSW, DSW)
151
BG
SRW2
153
Thyristor control units
S.
Switching power supply (SNT)
Braking units
SRE2
S.
Other
TST1
215
TST3
215
ESGT
216
w w w. tel e-o n l i n e. co m
Page 255
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising