- No category
advertisement
siemens.com/sitranst
Combining perfect senses and intelligence for every degree and condition
SITRANS T: highly accurate temperature sensors and transmitters with unique communication capabilities
Answers for industry.
Meeting all process industry‘s demands:
The SITRANS T family for temperature measurement
Whether it is about faster processes, higher product quality or quality control, optimized plant availability and safety, more efficient workflow or lower costs – process industries need to master a variety of demands for competitive advantage. Devices for measuring temperature are one but essential part to achieve these goals. With the product family SITRANS T
Siemens offers you a complete spectrum of temperature sensors and transmitters including comprehensive services – from a single source.
Your application requires individual components or complete solutions? No problem with SITRANS T. The product family delivers highly accurate temperature sensors and transmitters for every application in the process industry – even under extreme conditions: general purpose, intrinsically safe or explosion-proof and with globally recognized certificates. They are as easily integrated in different control systems as configurated. They prove highest flexibility as they are available as a complete measuring point with a widespread portfolio or as transmitter for head-, rail- or field-mount installation. Furthermore, they convince with communications capability and offer unique features as diagnostics displays. And to make the portfolio perfect,
Siemens supports you with application and process knowhow from worldwide presales and technical support to on-site servicing.
2
It’s all about communication – easy integration and configuration of SITRANS T
With SITRANS T you benefit from continuous ease of use and highest transparency – thanks to powerful software and a whole range of communications capabilities that allow the integration of field devices into the overall plant.
Most of our temperature transmitters use a communication based on industrial standards like HART, PROFIBUS PA or FOUNDATION Fieldbus. The EDD (Enhanced Device
Description) technology is used to integrate these devices in different process control systems like SIMATIC PCS 7.
SIMATIC PDM (Process Device Manager) is a consistent, vendor-independent tool for operation, setup, maintenance and diagnostics of intelligent field devices. It uses exactly these EDDs to operate devices with HART and
PROFIBUS PA communication. HART means here: wired
HART and WirelessHART which is part of HART V7.
So the new WirelessHART temperature transmitter can also be operated with SIMATIC PDM, based on a modern
EDD. Most devices are also integrated in third-party tools like HART Communicator or AMS.
For FOUNDATION Fieldbus, AMS or the F Communicator offer easy integration. For 4 - 20 mA devices without
HART a special tool SIPROM T is available for point-topoint communications. This tool reflects the advanced operating philosophy and look and feel of SIMATIC PDM, so that it is also familiar to the PDM user.
3
Precision where the temperature takes place:
SITRANS TS temperature sensors
SITRANS TS temperature sensors are the perfect base for accurate and secure temperature measurement. They support a very broad scope of different applications in the process industries. Equipped with our head-mount transmitters they provide easy system integration. With the optional display a comfortable read out of the process variable supports local operation and monitoring.
Benefits at a glance
• Broad portfolio support of all main applications
• Secure use in intrinsic safe and Ex d instrumented plants
• Modular system for easy configuration
• Support with 4 - 20 mA, HART, PROFIBUS PA and
FOUNDATION Fieldbus
4
Intelligence on-site:
SITRANS T temperature transmitters
SITRANS T temperature transmitters are the first choice to bring intelligence in your temperature sensor. The status of your measurement is easy to monitor remotely or locally. Unique support of maintenance such as two-color diagnostics LED and test pins let you detect with one glance suspect measurements and with one touch you measure the current loop without interruption of the measuring.
Benefits at a glance
• Support of various designs: head-, rail-, field-mount
• Easy integration in your system with 4 - 20 mA, HART,
PROFIBUS PA, FOUNDATION Fieldbus as well as
WirelessHART
• Extended diagnostics
• Maintenance benefits
5
6
The complete range
SITRANS TS temperature sensors
SITRANS TS100
This cable temperature sensor product series comes with a direct mounted cable. As a basic or mineral-insulated version a wide field of application is supported. The installation is easy and flexible by using compression or soldering fittings. With the optional adapter surface measurement is simple to apply. The intrinsic safe version has the approval for operating even in zone 0 without an additional protection tube. In such application the excellent response time of the sensor will be an outstanding benefit.
SITRANS TS500
The industry temperature sensor series supports a wide field of measurements, from simple applications up to solutions for harsh environments. Designed as a modular system of tubular or barstock thermowell, extension, connection head and optional transmitter and display, the customers profit from the use of standard components for individual applications. Intrinsic safe versions are available as well as Ex d.
SITRANS TS200
The compact temperature sensor series adds to the excellent benefits of our SITRANS TS100. Instead of the flexible cable, it comes with a fixed connection M12, Lemo etc.
SITRANS T temperature sensors – special for food and pharma
Our food and pharma temperature sensor product series is featured with a wide range of appropriate process connections – the classical method. With the clamp-on temperature sensor Siemens strikes a new path. Comparable with built-in measurement regarding response time and accuracy the advantages especially at small pipe diameters are obviously. No welding and welding validation, no process disturbance, easy pigging, easy dismantling for recalibration.
SITRANS T temperature transmitters
SITRANS TH
Weak sensor signal, expensive compensation cables, various I/O for each sensor type? The use of our SITRANS TH for mounting in the connection head of the temperature sensor makes you forget that troubles. The sensor signal is amplified and transmitted EMI-resistant to the control system. With the full range of outputs 4 - 20 mA, HART,
PROFIBUS PA, FOUNDATION Fieldbus you will profit from easy integration in your process control system. The galvanic insulation and the fault detection provide a proper operation. Further benefits are the outstanding maintenance options: extended diagnostics and unique diag- nostics displays that show the device status at a glance.
The technician simply connects an ammeter via the test sockets and can then read the output current without opening the measuring circuit. International engineering is no problem with the broad range of approvals e.g. for
Europe, USA, Canada and Brazil. Functional safety is certified for SIL 2/3 applications.
SITRANS TW
Looking for a Swiss army knife in temperature measurement, this real universal device is your choice. Multi- voltages power supply, 4 - 20 mA, 2 - 10 V, HART, relay output, individual curves are only an extract of the features of that device.
SITRANS TF
You have extreme environmental conditions? Temperature sensor mounted in an inconvenient location? With the rug- ged-built field device SITRANS TF, available in die-cast alu- minum or durable stainless steel housing, also harsh con- ditions can be coped. Mount your transmitter near to the sensor, but out of a hot zone of heat or vibration. Direct on the plant floor easy read out of the metering is your benefit.
SITRANS TR
You want to use the excellent features of the SITRANS TH family but prefer a centralized access to all connected measurement points in junction boxes or in the control room close to the process? SITRANS TR family, the twowire rail-mount transmitters, support this strategy in a perfect way.
SITRANS TF280
The SITRANS TF280 is a WirelessHART temperature transmitter that provides all measured process values as well as diagnostics information, parameters and functions via radio. The device is powered by an internal battery and designed for ultra-low power consumption. Its compact and rugged design makes it especially suitable for direct mounting on tanks and pipes in remote parts of plants, and on moving or rotating equipment for process monitoring or asset management applications.
7
SITRANS TS at a glance
8
Type SITRANS TS Insert SITRANS TS100 SITRANS TS200 SITRANS TS300 SITRANS TS500 SITRANS TS500 SITRANS TS500
Measuring inser spares
Mineral-insulated execution (MIC)
Temperature Sensors in cable version
Mineralinsulated version
Temperature Sensors in compact version
Mineral-insulated version
Temperature Sensors for
Food&Beverage/Pharma
In-pipe or clamp-on
Temperature Sensors for installation in existing thermowells
Suitable for thermowells according to DIN 43772 as well as
ASME B40.9-2001
Temperature Sensors with tubular thermowell for low to middle process load
Thermowell Form 2 or Form 3
(tapered) according to DIN 43772 and Form 2N; with thread, flange or without process connection
Temperature Sensors with barstock thermowell for high process load
Thermowell according to
DIN 43772 Form 4 for weld-in or Form 4F with flange
Application
Process connection
Certificates
Output
Wetted material
Spares Plant and machinery construction, bearing temperature, surface measurement
Compression or soldering fittings:
G [1/4, 1/2]“; 1/2“NPT; M8x1;
M18x1.5
Surface mounting adapter for installation on flat surfaces pipes
Plant and machinery construction, bearing temperature, surface measurement
Compression or soldering fittings:
G [1/4, 1/2]“; 1/2“NPT; M8x1;
M18x1.5
Surface mounting adapter for installation on flat surfaces pipes
For advanced hygienic requirements
In-pipe:
Clamp-flange; DIN 11851;
Varivent; BioControl; Neumo;
Ingold; spherical-welding-sleeve
Clamp-on: collar 4…57 mm strap up to 200 mm
Europe+IEC EX:
• intrinsic safety “ia”, “ic”
• for flameproof enclosure “d”; for dust protection by enclosure “t”
Europe+IEC EX:
• intrinsic safety “ia”, “ic”
Europe+IEC EX:
• intrinsic safety “ia”, “ic”
Direct sensor signal
4...20 mA (TH100/TH200)
HART (TH300)
PA (TH400)
FF (TH400)
SS similar 1.4404 (RTD),
2.4816 (Thermocouple)
(SS sim. 316L, Alloy 600)
Direct sensor signal
SS similar 1.4404 (RTD),
2.4816 (Thermocouple)
(SS sim. 316L, Alloy 600)
Direct sensor signal
SS similar 1.4404 (RTD),
2.4816 (Thermocouple)
(SS sim. 316L, Alloy 600)
Direct sensor signal
4 - 20 mA (TH100/TH200)
HART (TH300)
PA (TH400)
FF (TH400)
In-pipe:
1.4404/316L
Clamp-on: no wetted parts
Vessel and pipes
Connection to thermowell:
M18x1.5; G1/2“, 1/2“NPT
Europe+IEC EX:
• intrinsic safety “ia”, “ic”
• flameproof enclosure “d”;
dust protection by enclosure “t”
• non-sparking “n”
Direct sensor signal
4 - 20 mA (TH100/TH200)
HART (TH300)
PA (TH400)
FF (TH400) no wetted parts
Technical data
Temperature limits*
Minimum response time t
0,5
Ingress Protection
Pt100 Basic: –30...+400 °C
Pt100 Extend: –196...+600 °C
Thermocouple: –196...+1100 °C
(depends on type)
2...6s
IP54
Pt100 Basic: –30...+400 °C
Pt100 Extend: –196...+600 °C
Thermocouple: –196...+1100 °C
(depends on type)
2...6s
IP54
* Combination of loads (temperature, flow, vibration, pressure) lower this values partly extensive.
Further temperature limits are a result of the used thermowell materials
(e.g. 1.4571 / 316Ti resistant to compression stress until 450...550 °C, material limit 800 °C.)
Pt100 Basic: –30...+400 °C
Pt100 Extend: –196...+600 °C
Thermocouple: –196...+1100 °C
(depends on type)
2...6s
IP54
(some connetors lower)
In-pipe:
–30…+300 °C
Clamp-on:
–20…+160 °C
5 s
IP65 (IP54 at some head types)
Pt100 Basic: –30...+400 °C
Pt100 Extend: –196...+600 °C
Thermocouple: –196...+1100 °C
(depends on type)
Depends on type of thermowell
IP65 (IP54 at some head types)
Vessel and pipes Vessel and pipes
Compression fitting G1/2“; 1/2“NPT; welded thread
G1/2“; G1“; 1/2“NPT; welded flange
DN25PN40; 1RF150; 1.5RF150;
1.5RF300
Form 4 for weld-in
Form 4F with flange:
DN25PN40; 1RF150;
1RF300; 1.5RF150; 1.5RF300
Europe+IEC EX:
• intrinsic safety “ia”, “ic”
• flameproof enclosure “d”;
dust protection by enclosure “t”
• non-sparking “n”
Direct sensor signal
4 - 20 mA (TH100/TH200)
HART (TH300)
PA (TH400)
FF (TH400)
1.4404; 1.4571
(316L; 316TI)
Europe+IEC EX:
• intrinsic safety “ia”, “ic”
• flameproof enclosure “d”;
dust protection by enclosure “t”
• non-sparking “n”
Direct sensor signal
4 - 20 mA (TH100/TH200)
HART (TH300)
PA (TH400)
FF (TH400)
Form 4F: 1.4404; 1.4571
(316L; 316TI)
Form 4 additionally 1.7335; 1.5415
(A 182 F11; A 204 Gr.A)
Pt100 Basic: –30...+400 °C
Pt100 Extend: –196...+600 °C
Thermocouple: –196...+1100 °C
(depends on type)
7...45s
IP65 (IP54 at some head types)
Pt100 Basic: –30...+400 °C
Pt100 Extend: –196...+600 °C
Thermocouple: –196...+1100 °C
(depends on type)
20...45s
IP65 (IP54 at some head types)
SITRANS TS at a glance
Type SITRANS TS Insert SITRANS TS100 SITRANS TS200 SITRANS TS300 SITRANS TS500 SITRANS TS500 SITRANS TS500
Measuring inser spares
Mineral-insulated execution (MIC)
Temperature Sensors in cable version
Mineralinsulated version
Temperature Sensors in compact version
Mineral-insulated version
Temperature Sensors for
Food&Beverage/Pharma
In-pipe or clamp-on
Temperature Sensors for installation in existing thermowells
Suitable for thermowells according to DIN 43772 as well as
ASME B40.9-2001
Temperature Sensors with tubular thermowell for low to middle process load
Thermowell Form 2 or Form 3
(tapered) according to DIN 43772 and Form 2N; with thread, flange or without process connection
Temperature Sensors with barstock thermowell for high process load
Thermowell according to
DIN 43772 Form 4 for weld-in or Form 4F with flange
Application
Process connection
Certificates
Output
Wetted material
Spares Plant and machinery construction, bearing temperature, surface measurement
Compression or soldering fittings:
G [1/4, 1/2]“; 1/2“NPT; M8x1;
M18x1.5
Surface mounting adapter for installation on flat surfaces pipes
Plant and machinery construction, bearing temperature, surface measurement
Compression or soldering fittings:
G [1/4, 1/2]“; 1/2“NPT; M8x1;
M18x1.5
Surface mounting adapter for installation on flat surfaces pipes
For advanced hygienic requirements
In-pipe:
Clamp-flange; DIN 11851;
Varivent; BioControl; Neumo;
Ingold; spherical-welding-sleeve
Clamp-on: collar 4…57 mm strap up to 200 mm
Europe+IEC EX:
• intrinsic safety “ia”, “ic”
• for flameproof enclosure “d”; for dust protection by enclosure “t”
Europe+IEC EX:
• intrinsic safety “ia”, “ic”
Europe+IEC EX:
• intrinsic safety “ia”, “ic”
Direct sensor signal
4...20 mA (TH100/TH200)
HART (TH300)
PA (TH400)
FF (TH400)
SS similar 1.4404 (RTD),
2.4816 (Thermocouple)
(SS sim. 316L, Alloy 600)
Direct sensor signal
SS similar 1.4404 (RTD),
2.4816 (Thermocouple)
(SS sim. 316L, Alloy 600)
Direct sensor signal
SS similar 1.4404 (RTD),
2.4816 (Thermocouple)
(SS sim. 316L, Alloy 600)
Direct sensor signal
4 - 20 mA (TH100/TH200)
HART (TH300)
PA (TH400)
FF (TH400)
In-pipe:
1.4404/316L
Clamp-on: no wetted parts
Vessel and pipes
Connection to thermowell:
M18x1.5; G1/2“, 1/2“NPT
Europe+IEC EX:
• intrinsic safety “ia”, “ic”
• flameproof enclosure “d”;
dust protection by enclosure “t”
• non-sparking “n”
Direct sensor signal
4 - 20 mA (TH100/TH200)
HART (TH300)
PA (TH400)
FF (TH400) no wetted parts
Technical data
Temperature limits*
Minimum response time t
0,5
Ingress Protection
Pt100 Basic: –30...+400 °C
Pt100 Extend: –196...+600 °C
Thermocouple: –196...+1100 °C
(depends on type)
2...6s
IP54
Pt100 Basic: –30...+400 °C
Pt100 Extend: –196...+600 °C
Thermocouple: –196...+1100 °C
(depends on type)
2...6s
IP54
* Combination of loads (temperature, flow, vibration, pressure) lower this values partly extensive.
Further temperature limits are a result of the used thermowell materials
(e.g. 1.4571 / 316Ti resistant to compression stress until 450...550 °C, material limit 800 °C.)
Pt100 Basic: –30...+400 °C
Pt100 Extend: –196...+600 °C
Thermocouple: –196...+1100 °C
(depends on type)
2...6s
IP54
(some connetors lower)
In-pipe:
–30…+300 °C
Clamp-on:
–20…+160 °C
5 s
IP65 (IP54 at some head types)
9
Pt100 Basic: –30...+400 °C
Pt100 Extend: –196...+600 °C
Thermocouple: –196...+1100 °C
(depends on type)
Depends on type of thermowell
IP65 (IP54 at some head types)
Vessel and pipes Vessel and pipes
Compression fitting G1/2“; 1/2“NPT; welded thread
G1/2“; G1“; 1/2“NPT; welded flange
DN25PN40; 1RF150; 1.5RF150;
1.5RF300
Form 4 for weld-in
Form 4F with flange:
DN25PN40; 1RF150;
1RF300; 1.5RF150; 1.5RF300
Europe+IEC EX:
• intrinsic safety “ia”, “ic”
• flameproof enclosure “d”;
dust protection by enclosure “t”
• non-sparking “n”
Direct sensor signal
4 - 20 mA (TH100/TH200)
HART (TH300)
PA (TH400)
FF (TH400)
1.4404; 1.4571
(316L; 316TI)
Europe+IEC EX:
• intrinsic safety “ia”, “ic”
• flameproof enclosure “d”;
dust protection by enclosure “t”
• non-sparking “n”
Direct sensor signal
4 - 20 mA (TH100/TH200)
HART (TH300)
PA (TH400)
FF (TH400)
Form 4F: 1.4404; 1.4571
(316L; 316TI)
Form 4 additionally 1.7335; 1.5415
(A 182 F11; A 204 Gr.A)
Pt100 Basic: –30...+400 °C
Pt100 Extend: –196...+600 °C
Thermocouple: –196...+1100 °C
(depends on type)
7...45s
IP65 (IP54 at some head types)
Pt100 Basic: –30...+400 °C
Pt100 Extend: –196...+600 °C
Thermocouple: –196...+1100 °C
(depends on type)
20...45s
IP65 (IP54 at some head types)
SITRANS TH, TR, TW and TF at a glance
Installation In the connection head
Two-wire
On DIN rail
Two-wire Four-wire
Field device
Two-wire Wireless
Type
Input
(connectable sensors)
Output
Local display
SITRANS TH100
Pt100 resistance thermometers
4 - 20 mA
N/A
SITRANS TH200
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
4 - 20 mA
N/A
SITRANS TH300
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
4 - 20 mA, HART
N/A
SITRANS TH400
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
PROFIBUS PA version
FOUNDATION Fieldbus version
N/A
Power supply
Housing material
8.5 - 36 V DC
(30 V for Ex)
Molded plastic, embedded electronics
–40...+85 °C
11 - 35 V DC
(30 V for Ex)
Molded plastic, embedded electronics
–40...+85 °C
11 - 35 V DC
(30 V for Ex)
Molded plastic, embedded electronics
–40...+85 °C
9 - 32 V DC
(30 V for Ex and
17.5 V for FISCO)
Molded plastic,
embedded electronics
–40...+85 °C
Ambient temperature
Degree of protection
Certificates
IP40 IP40 IP40 IP40
Operator input
SIMATIC PDM
Handheld 375
AMS
SIPROM T and special modem
Local configuration using
3 push buttons
•
Europe (ATEX): Ex ia, ib, ic,
Ex n
USA (cFMus): IS, NI
Canada (cFMus): IS, NI other certificates:
GOST,NEPSI,PESO
Europe (ATEX): Ex ia, ib, ic,
Ex n
USA (cFMus): IS, NI
Canada (cFMus): IS, NI,
NiFW, DIP
SIL 2 und SIL2/3 other certificates:
GOST,NEPSI,PESO,EXPLABS
Europe (ATEX): Ex ia, ib, ic
Ex n
USA (cFMus): IS, NI
Canada (cFMus): IS, NI,
NiFW, DIP
SIL 2 und SIL2/3 other certificates:
GOST,NEPSI,PESO,EXPLABS
Europe (ATEX): Ex ia, Ex n
Ex ib, Ex n
USA (cFMus): IS, NI
Canada (cFMus): IS, NI other certificates:
GOST, PESO
•
•
•
•
PROFIBUS PA
FOUNDATION Fieldbus
FF version
FF version
10
•
SITRANS TR200
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
4 - 20 mA
SITRANS TR300
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
4 - 20 mA, HART
SITRANS TW
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
0/4 - 20 mA, HART
0/2 - 10 V, HART
SITRANS TF
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
Current sources
4 - 20 mA
4 - 20 mA, HART
PROFIBUS PA
FOUNDATION Fieldbus
LCD (with version
4 - 20 mA and 4 - 20 mA,
HART)
SITRANS TF280
Pt100 resistance thermometer
WirelessHART back-lighted LCD
11 - 35 V DC
(30 V for Ex ia)
Molded plastic
–40 - +85 °C
11 - 35 V DC
(30 V for Ex ia)
Molded plastic
–40 - +85 °C
115/230 V UC or 24 V UC
Molded plastic
–25 - +70 °C
DC 11/13,5 - 35V
(30 V for Ex ia and
17.5 V for FISCO)
Varnished die-cast aluminum or stainless steel
–40 - +85 °C
Lithium thionyl battery
D-cell 3.6 V
Varnished die-cast aluminum
–40 - +80 °C
IP20 IP20 IP20 IP67
Europe (ATEX): Ex ia or
Ex ib, Ex n
SIL 2 und SIL2/3 other certificates:
NEPSI
Europe (ATEX): Ex ia or
Ex ib, Ex n
SIL 2 und SIL2/3 other certificates:
NEPSI
Europe (ATEX): Ex (ia) or
Ex (ib)
SIL 1 other certificates:
GOST
Europe (ATEX): Ex ia,
Ex d, Ex n
USA: XP/DIP/NI/S
SIL 2 und SIL2/3 (4...20 mA/HART) other certificates:
GOST,INMETRO,
NEPSI,KOSHA
IP65
R&TTE, FCC
•
•
•
•
•
•
HART / PROFIBUS PA/
FOUNDATION Fieldbus
HART / FOUNDATION
Fieldbus
HART / FOUNDATION
Fieldbus
4...20 mA
•
•
SITRANS TH, TR, TW and TF at a glance
Installation In the connection head
Two-wire
On DIN rail
Two-wire Four-wire
Field device
Two-wire Wireless
Type
Input
(connectable sensors)
Output
Local display
SITRANS TH100
Pt100 resistance thermometers
4 - 20 mA
N/A
SITRANS TH200
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
4 - 20 mA
N/A
SITRANS TH300
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
4 - 20 mA, HART
N/A
SITRANS TH400
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
PROFIBUS PA version
FOUNDATION Fieldbus version
N/A
Power supply
Housing material
8.5 - 36 V DC
(30 V for Ex)
Molded plastic, embedded electronics
–40...+85 °C
11 - 35 V DC
(30 V for Ex)
Molded plastic, embedded electronics
–40...+85 °C
11 - 35 V DC
(30 V for Ex)
Molded plastic, embedded electronics
–40...+85 °C
9 - 32 V DC
(30 V for Ex and
17.5 V for FISCO)
Molded plastic,
embedded electronics
–40...+85 °C
Ambient temperature
Degree of protection
Certificates
IP40 IP40 IP40 IP40
Operator input
SIMATIC PDM
Handheld 375
AMS
SIPROM T and special modem
Local configuration using
3 push buttons
•
Europe (ATEX): Ex ia, ib, ic,
Ex n
USA (cFMus): IS, NI
Canada (cFMus): IS, NI other certificates:
GOST,NEPSI,PESO
Europe (ATEX): Ex ia, ib, ic,
Ex n
USA (cFMus): IS, NI
Canada (cFMus): IS, NI,
NiFW, DIP
SIL 2 und SIL2/3 other certificates:
GOST,NEPSI,PESO,EXPLABS
Europe (ATEX): Ex ia, ib, ic
Ex n
USA (cFMus): IS, NI
Canada (cFMus): IS, NI,
NiFW, DIP
SIL 2 und SIL2/3 other certificates:
GOST,NEPSI,PESO,EXPLABS
Europe (ATEX): Ex ia, Ex n
Ex ib, Ex n
USA (cFMus): IS, NI
Canada (cFMus): IS, NI other certificates:
GOST, PESO
•
•
•
•
PROFIBUS PA
FOUNDATION Fieldbus
FF version
FF version
•
SITRANS TR200
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
4 - 20 mA
SITRANS TR300
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
4 - 20 mA, HART
SITRANS TW
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
0/4 - 20 mA, HART
0/2 - 10 V, HART
SITRANS TF
Resistance thermometers
Thermocouples
Resistance-type sensors
DC sources
Current sources
4 - 20 mA
4 - 20 mA, HART
PROFIBUS PA
FOUNDATION Fieldbus
LCD (with version
4 - 20 mA and 4 - 20 mA,
HART)
SITRANS TF280
Pt100 resistance thermometer
WirelessHART back-lighted LCD
11 - 35 V DC
(30 V for Ex ia)
Molded plastic
–40 - +85 °C
11 - 35 V DC
(30 V for Ex ia)
Molded plastic
–40 - +85 °C
115/230 V UC or 24 V UC
Molded plastic
–25 - +70 °C
DC 11/13,5 - 35V
(30 V for Ex ia and
17.5 V for FISCO)
Varnished die-cast aluminum or stainless steel
–40 - +85 °C
Lithium thionyl battery
D-cell 3.6 V
Varnished die-cast aluminum
–40 - +80 °C
IP20 IP20 IP20 IP67
Europe (ATEX): Ex ia or
Ex ib, Ex n
SIL 2 und SIL2/3 other certificates:
NEPSI
Europe (ATEX): Ex ia or
Ex ib, Ex n
SIL 2 und SIL2/3 other certificates:
NEPSI
Europe (ATEX): Ex (ia) or
Ex (ib)
SIL 1 other certificates:
GOST
Europe (ATEX): Ex ia,
Ex d, Ex n
USA: XP/DIP/NI/S
SIL 2 und SIL2/3 (4...20 mA/HART) other certificates:
GOST,INMETRO,
NEPSI,KOSHA
IP65
R&TTE, FCC
•
•
•
•
•
•
HART / PROFIBUS PA/
FOUNDATION Fieldbus
HART / FOUNDATION
Fieldbus
HART / FOUNDATION
Fieldbus
4...20 mA
•
•
11
More information:
www.siemens.com/sitranst www.siemens.com/processinstrumentation
Siemens AG
Industry Sector
Sensors and Communication
76181 KARLSRUHE
GERMANY
Subject to change without prior notice 09/12
Order No.: E20001-A930-P710-V1-7600
DISPO 27900
21/36212 MI.SC.PS.XX01.52.2.06
WS 09125.0
Printed in Germany
© Siemens AG 2012
The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract.
All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement