MODEL: KL Plug-in Signal Conditioners K-UNIT LIMITER (non-isolated) Functions & Features • Preventing DC output signals from going above or below preset values • High and low limits independently adjustable over entire range • Monitor jacks provided for setpoint adjustments • High-density mounting Typical Applications • Securing the minimum fuel flow in a combustion control loop 50 (1.97) 80 (3.15) K•UNIT 123 (4.84) mm (inch) MODEL: KL–[1][2]–[3] ORDERING INFORMATION • Code number: KL-[1][2]-[3] Specify a code from below for each [1] through [3]. (e.g. KL-6A-B) • Special input and output ranges (For codes Z & 0) [1] INPUT Current A: 4 – 20 mA DC (Input resistance 250 Ω) A1: 4 – 20 mA DC (Input resistance 50 Ω) B: 2 – 10 mA DC (Input resistance 500 Ω) C: 1 – 5 mA DC (Input resistance 1000 Ω) D: 0 – 20 mA DC (Input resistance 50 Ω) E: 0 – 16 mA DC (Input resistance 62.5 Ω) F: 0 – 10 mA DC (Input resistance 100 Ω) G: 0 – 1 mA DC (Input resistance 1000 Ω) H: 10 – 50 mA DC (Input resistance 100 Ω) J: 0 – 10 μA DC (Input resistance 1000 Ω) K: 0 – 100 μA DC (Input resistance 1000 Ω) GW: -1 – +1 mA DC (Input resistance 1000 Ω) FW: -10 – +10 mA DC (Input resistance 100 Ω) Z: Specify current (See INPUT SPECIFICATIONS) http://www.m-system.co.jp/ Voltage 1: 0 – 10 mV DC (Input resistance 10 kΩ min.) 15: 0 – 50 mV DC (Input resistance 10 kΩ min.) 16: 0 – 60 mV DC (Input resistance 10 kΩ min.) 2: 0 – 100 mV DC (Input resistance 100 kΩ min.) 3: 0 – 1 V DC (Input resistance 1 MΩ min.) 4: 0 – 10 V DC (Input resistance 1 MΩ min.) 5: 0 – 5 V DC (Input resistance 1 MΩ min.) 6: 1 – 5 V DC (Input resistance 1 MΩ min.) 4W: -10 – +10 V DC (Input resistance 1 MΩ min.) 5W: -5 – +5 V DC (Input resistance 1 MΩ min.) 0: Specify voltage (See INPUT SPECIFICATIONS) [2] OUTPUT Current A: 4 – 20 mA DC (Load resistance 750 Ω max.) B: 2 – 10 mA DC (Load resistance 1500 Ω max.) C: 1 – 5 mA DC (Load resistance 3000 Ω max.) D: 0 – 20 mA DC (Load resistance 750 Ω max.) E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) G: 0 – 1 mA DC (Load resistance 15 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 3: 0 – 1 V DC (Load resistance 100 Ω min.) 4: 0 – 10 V DC (Load resistance 1000 Ω min.) 5: 0 – 5 V DC (Load resistance 500 Ω min.) 6: 1 – 5 V DC (Load resistance 500 Ω min.) 4W: -10 – +10 V DC (Load resistance 2000 Ω min.) 5W: -5 – +5 V DC (Load resistance 1000 Ω min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS) [3] POWER INPUT AC Power B: 100 V AC C: 110 V AC D: 115 V AC F: 120 V AC G: 200 V AC H: 220 V AC J: 240 V AC DC Power S: 12 V DC R: 24 V DC GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3.5 screw terminals Housing material: Flame-resistant resin (black) KL SPECIFICATIONS ES-3628 Rev.6 Page 1/4 MODEL: KL Isolation: Input or output to power Overrange output: Approx. -5 to +105 % at 1 – 5 V Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front) Limit adjustments: Multi-turn screwdriver adjustments (front); 0 – 100 %; factory set to 0 % for low, 100 % for high Monitor output: 0 – 10 V for 0 – 100 % limit Monitor jacks: 2 mm (.08") dia. Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input or output to power to ground) INPUT SPECIFICATIONS • DC Current: Shunt resistor attached to the input terminals (0.5 W) Specify input resistance value for code Z. • DC Voltage: -300 – +300 V DC Minimum span: 3 mV Offset: Max. 1.5 times span Input resistance Span 3 – 10 mV : ≥ 10 kΩ Span 10 – 100 mV : ≥ 10 kΩ Span 0.1 – 1 V : ≥ 100 kΩ Span ≥ 1 V : ≥ 1 MΩ OUTPUT SPECIFICATIONS • DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. • DC Voltage: -10 – +12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 10 mA max.; 5 mA for negative voltage output; at ≥ 0.5 V INSTALLATION Power input AC: Operational voltage range: rating ±10 %, 50/60 ±2 Hz, approx. 2 VA DC: Operational voltage range: rating ±10 %, ripple 10 %p-p max., approx. 2 W (90 mA at 24 V) Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 300 g (0.66 lbs) PERFORMANCE in percentage of span Accuracy: ±0.1 % Limit monitor accuracy: ± 0.25 % Temp. coefficient: ±0.02 %/°C (±0.01 %/°F) Response time: ≤ 0.5 sec. (0 – 90 %) Line voltage effect: ±0.1 % over voltage range http://www.m-system.co.jp/ KL SPECIFICATIONS ES-3628 Rev.6 Page 2/4 MODEL: KL EXTERNAL VIEW Lo Limit Adj. Hi Limit Adj. COM. Zero Adj. Lo Limit Monitor Span Adj. Hi Limit Monitor DIMENSIONS unit: mm (inch) CLAMP (top & bottom) 20 (.79) 7.8 (.31) 5 4 3 7 8 1 2 2–4.5 (.18) dia. MTG HOLE 15 (.59) deep 8–M3.5 SCREW 50 (1.97) 6 80 (3.15) 80 (3.15) 35.4 (1.39) DIN RAIL 35mm wide 103 (4.06) 40 (1.57) 123 (4.84) [3.3 (.13)] 50 (1.97) • When mounting, no extra space is needed between units. TERMINAL ASSIGNMENTS unit: mm (inch) 6 5 4 3 7 8 1 2 12 (.47) INPUT RESISTOR (model: REM) Input shunt resistor attached for current input. http://www.m-system.co.jp/ KL SPECIFICATIONS ES-3628 Rev.6 Page 3/4 MODEL: KL SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM COM. HI LO Z + INPUT R – * 3 Low Drift Amplifier Hi / Lo Limiter S Output Driver 1 + OUTPUT 4 2 – 5 7 U(+) 6 8 V(–) POWER Base Socket *Input shunt resistor attached for current input. Specifications are subject to change without notice. http://www.m-system.co.jp/ KL SPECIFICATIONS ES-3628 Rev.6 Page 4/4
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement