SERVICE SUPPLEMENT

TO 39132.0000

BUNN-O-MATIC CORPORATION

POST OFFICE BOX 3227

SPRINGFIELD, ILLINOIS 62708-3227

PHONE: (217) 529-6601 FAX: (217) 529-6644

39132.0003D 03/14 ©2010 Bunn-O-Matic Corporation

BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY

Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:

1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCR/MCP/MCA single cup brewers, thermal servers and ThermoFresh® servers (mechanical and digital) 1 year parts and 1 year labor.

2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below: a) Electronic circuit and/or control boards - parts and labor for 3 years.

b) Compressors on refrigeration equipment - 5 years parts and 1 year labor.

c) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis - parts and labor for 4 years or 40,000 pounds of coffee, whichever comes first.

These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality, damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box

3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized

BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EX-

PRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY

OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon.

If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.

THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS

EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION

AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.

In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.

392, A Partner You Can Count On, Air Infusion, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, Brew-

WISE, BrewWIZARD, BUNN Espress, BUNN Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with the stylized red line, BUNNlink, Bunn-OMatic, Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design,

Cool Froth, DBC, Dr. Brew stylized Dr. design, Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet

Juice, High Intensity, iMIX, Infusion Series, Intellisteam, My Café, Phase Brew, PowerLogic, Quality Beverage Equipment

Worldwide, Respect Earth, Respect Earth with the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com,

Scale-Pro, Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in

Beverage Equipment Worldwide, ThermoFresh, Titan, trifecta, TRIFECTA (sylized logo), Velocity Brew, Air Brew, Beverage

Bar Creator, Beverage Profit Calculator, Brew better, not bitter., Build-A-Drink, BUNNSource, Coffee At Its Best, Cyclonic

Heating System, Daypart, Digital Brewer Control, Element, Milk Texturing Fusion, Nothing Brews Like a BUNN, Picture

Prompted Cleaning, Pouring Profits, Signature Series, Sure Tamp, Tea At Its Best, The Horizontal Red Line, Ultra are either trademarks or registered trademarks of Bunn-O-Matic Corporation. The commercial trifecta® brewer housing configuration is a trademark of Bunn-O-Matic Corporation.

Page 2 39132.3 031314

INTRODUCTION

This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It can be easily configured for

120V 15 amp, 120/208V 20 amp or 120/240V 20 amp. The brewer may have a hot water faucet for allied beverage use.

It is only for indoor use on a sturdy counter or shelf.

CONTENTS

Warranty .................................................................................2

Contents ..................................................................................3

Programming ............................................................................4

Schematic Wiring Diagram ......................................................... 10

Page 3 39132.3 040312

PROGRAMMING

PROGRAMMING THE BREWER

The information in this manual covers only the differences between this model and the standard Axiom.

Access to service level 4 is same as standard Axiom.

The following function screens are in order of appearance. Each screen will have instructions on how to access, and the procedures to program the various functions of the brewer.

IMPORTANT PROGRAMMING NOTES

- READ CAREFULLY -

To exit the programming mode at any time, press and release "ENABLE BREW ON/OFF" switch located on the front switch panel. The display will return to the MAIN SCREEN.

If none of the programming switches are pressed within one minute during the setup of the brewer, the programming of the function screen that is being set will be exited and the display will return to the MAIN

SCREEN.

Always remember to place an empty server and funnel under the sprayhead when operating the brewer during the set-up of PULSE BREW, CALIBRATE FLOW and testing the brew valve in TEST OUTPUTS.

PROGRAMMING LOCKOUT SWITCH

(Mounted on main control board)

This switch can be set to prevent access to the programming settings of the brewer. Once all the correct brew settings are programmed, the operator can set the switch to the "LOCK" position to prohibit anyone from changing the settings. With the switch in the "LOCK" position, the programming menus can still be accessed to view the current settings. However, no changes will be saved.

LOCK

SET

Disconnect brewer from power source before removing any panel!

READY TO BREW

WATER TEMP: 200°

Push and hold left "hidden" button to access service program modes.

Page 4 39132.3 040312

SERVICE PROGRAMMING

Freq&AdjustCaps?

NO YES

DISPLAY BREW TIMES

NO YES

TEST RFID BOARD

NO YES

FRESHNESS TIMEOUT

NO YES

GLASS FRESH HRS

(-) .5 (+)

ThermalFresh HRS

(-) 2.0 (+)

WARMER MINs PAST

FRESHNESS: 5

FRESHNESS SCAN

NO DONE YES

EXPIRATION ALARM

DISABLE ENABLE

EXPIRATION SECS

(-) 10 (+)

ADJUST ALARM

NO VOLUME ? YES

SET DATE/TIME ?

NO YES

PRE-EXPIRE ALARM

DISABLE ENABLE

Return To Main Screen

AXIOM

VERSION xx.xx

Displays Model &

Software Version

Page 5 39132.3 040312

Freq&AdjustCaps?

NO YES

SERVICE PROGRAMMING

This allows you to monitor the frequency of the warmer(s) sensing coils.

125.0 0000 * TOP F

125.0 0000 * TOP R

Also allows you to monitor the adjustment capacitors, which are used to keep the coil frequency at it's nominal value (125.0 khz)

125.0 0000 * MAIN

Use the "Brewer" button to toggle between screens.

Press right hidden button to advance to next function.

DISPLAY BREW TIMES

NO YES

This allows you to read the "age" of any brewed batch in a particular carafe (as long as it is equipped with an RFID chip). The sensor coil will read the chip and brewer will display time of day it was brewed.

MAY 10 2010

MAIN 10:00:00 AM

This screen will automatically scroll through all warmers.

Press right hidden button to advance to next function.

TEST RFID BOARD

NO YES

This allows you to monitor individual sensing coils and RFID board.

RFID CIRCUIT BOARD

VERSION # xx.xx

CONTINUED

Page 6 39132.3 040312

PRESS ANY SWITCH

TO EXIT

SERVICE PROGRAMMING

M

10:00:00 AM

TF TR

GLASS FRESH HRS

(-) .5 (+)

ThermalFresh HRS

(-) 2.0 (+)

WARMER MINs PAST

FRESHNESS: 5

If a carafe is placed on a particular warmer, a "box" will appear next to it's indicator. If the box is filled (solid) it's not expired yet. If the box is empty, the time is expired. See example: MAIN = expired; Top

Front = not expired; Top Rear = expired.

Press right hidden button to advance to next function.

Enables the "FRESHNESS ALERT!" message and sets the expiration time. The expiration time is the amount of time the product is allowed to sit in the glass decanter before an alert message is displayed.

DEFAULT: .5

Range: OFF/0.5 - 4.0 hrs

Enables the "FRESHNESS ALERT!" message and sets the expiration time. The expiration time is the amount of time the product is allowed to sit in the thermal server before an alert message is displayed.

DEFAULT: 2.0

Range: OFF/0.5 - 4.0 hrs

Sets the amount of time the warmers will turn off after an alert message is displayed. DEFAULT: 5

Range: OFF/1 - 30 min

FRESHNESS SCAN

NO DONE YES

Allows brewer to continually scan the warmer sensor coils and display freshness times.

EXPIRATION ALARM

DISABLE ENABLE

Enable/Disable beeper.

CONTINUED

Page 7 39132.3 040312

EXPIRATION SECS

(-) 10 (+)

SERVICE PROGRAMMING

Sets the amount of delay between alarm beeps.

ADJUST ALARM

NO VOLUME ? YES

Select "YES" to adjust beeper volume.

ADJUST ALARM 5

- +

Press "+" to increase volume, or "-" to decrease.

SET DATE/TIME ?

NO YES

Select "YES" to set date and/or time.

YEAR 2010

(-) DONE (+)

Press "+" to scroll year forward, or "-" to scroll year back.

MONTH MAY

(-) DONE (+)

Press "+" to scroll month forward, or "-" to scroll month back.

DAY 10

(-) DONE (+)

Press "+" to scroll day forward, or "-" to scroll day back.

CONTINUED

Page 8 39132.3 040312

HOUR 10 AM

(-) DONE (+)

SERVICE PROGRAMMING

Press "+" to scroll hour forward, or "-" to scroll hour back.

MINUTE 00

(-) DONE (+)

Press "+" to scroll minute forward, or "-" to scroll minute back.

SECOND 00

(-) DONE (+)

Press "+" to scroll seconds forward, or "-" to scroll seconds back.

PRE-EXPIRE ALARM

DISABLE ENABLE

Enable/disable the 5 minute warning beep for a carafe about to expire.

EXIT

Page 9 39132.3 040312

SCHEMATIC WIRING DIAGRAM

AXIOM BrewWISE-CE

L1

GRN/YEL

L2

BLK

BLK-14

LIMIT

WHI

THERMOSTAT

BLU-14

O

A

C

B

R

D

L

P

R

O

N

T

C

O

RELAY

J1-1

J1-5

J1-10

J13-1

BLU-14

BLK-14

WHI

BLK

BRN/BLK

WHI/BLU

WHI/RED

YEL

WHI/VIO

VIO

WHI/GRN

J13-5

BRN

RED

ORN

YEL

GRN

BLU

J1-1

J5-1

J6-1

J1-5

RFID

BOARD

J7-1

BLK RED

EMI

FILTER

BLK WHI

BLK-14

THERMAL

FUSE

"KEEP WARM" HEATER

TANK HEATER

THERMAL

FUSE

WHI-14

WHI/RED

DISPENSE

WHI

BREW STATION WARMER

(CONTROLLED BY ON/OFF SW)

REFILL

WHI/BLU

SOL

WHI

WHI

WHI

WHI/GRN

SOL

WHI

WHI

BRN/BLK

P2

(TOP OR RIGHT WARMERS)

BRN/BLK

FRONT WARMER

WHI

P1

WHI

TOP REAR WARMER SENSOR

VIO

P3

YEL

P2

VIO

YEL

REAR WARMER

(LEFT WARMER)

FRONT WARMER

W

I

WHI

P1, P2, &

P3 ARE

PINS OF A

POLARIZED

THREE-PIN

CONNECTOR.

P1

WHI

LOWER WARMER SENSOR

WHI/VIO

P3

WHI/VIO

REAR WARMER

W

H

I

TOP FRONT WARMER SENSOR

J12-1

RED

BLK

J2-1

BEEPER

STATIC

SHIELD

CONTROL SWITCH ASSY

(NOTE – ALL WARMERS ARE NOT

AVAILABLE ON ALL MODELS!)

J2-6

J2-10

B1 A6 D1 A3 D2 A4 D3 A5 B2 A2 A1

BREW STATION

LEFT FRONT

LEFT REAR

TOP FRONT

TOP REAR

RIGHT FRONT

RIGHT REAR

START BREW

LEFT HIDDEN

RIGHT HIDDEN

“DIGITAL”

“BREWER”

“CONTROL”

CONTROL SWITCH ASSY CODES

2 WARMERS

ON LEFT

2 WARMERS

ON TOP

2 WARMERS

ON RIGHT

A3

A2

A1

A3 A3

A5

A6

A5

A6

A4

B1

B2

A4

B1

B2

A4

B1

B2

D1

D2

D3

D1

D2

D3

D1

D2

D3

J3-1

J3-3

J9-1

BRN

GRN

BLU

WHI

BLK

230 VOLTS CE

2 WIRE + GND

SINGLE PHASE

50 HZ t °

LEVEL PROBE (SHORT)

LEVEL PROBE (LONG)

29077.0027A 08/12 ©2012 BUNN-O-MATIC CORPORATION

Page 10 39132.3 021914

Plain White 20# Bond Paper

Black Ink

Finished Size: 11" x 17"

~100%

BLK-14

BLK

BLK-14

SCHEMATIC WIRING DIAGRAM

AXIOM BrewWISE 120, DV 120/208-240

Earth Ground

GRN

Chassis Ground

MAIN ON/OFF SWITCH

(Late Models only)

L1 L2

LIMIT

THERMOSTAT

BLU-14

RED-14 208-240V Models ONLY

WHI-14 120V Models ONLY

BLK-14

TANK HEATER

BLU-14

SELECTOR SWITCH

WHI-14

WHI/VIO-14

DV ONLY

TANK HEATER

DV ONL

RED-14

N

O

A

C

B

R

D

L

P

R

O

N

T

C

O

RELAY

J1-1

J1-5

J1-10

BLU-14

BLK-14

WHI

BLK

BRN/BLK

WHI/BLU

WHI/RED

YEL

WHI/VIO

VIO

WHI/GRN

J13-1

J13-5

BRN

RED

ORN

YEL

GRN

BLU

J1-1

J5-1

J6-1

J1-5

RFID

BOARD

J7-1

TOP REAR WARMER SENSOR

LOWER WARMER SENSOR

TOP FRONT WARMER SENSOR

J12-1

RED

BLK BEEPER

WHI/RED

BREW STATION WARMER

(CONTROLLED BY ENABLE BREW SW)

WHI/BLU

WHI/GRN

DISPENSE

SOL

REFILL

SOL

WHI

WHI

WHI

WHI

P2

P3

(TOP or RIGHT WARMERS)

BRN/BLK

FRONT WARMER

WHI

VIO

REAR WARMER

W

I

P1

WHI

P2

(LEFT WARMER)

WHI/VIO

FRONT WARMER

WHI

P1

WHI

P3

YEL

REAR WARMER

W

I

J2-1

J2-5

J2-10

J3-1

J3-3

J9-1

BRN

GRN

BLU

WHI

BLK

STATIC

SHIELD

CONTROL SWITCH ASSY

(NOTE – ALL WARMERS ARE NOT

AVAILABLE ON ALL MODELS!)

B1 A6 D1 A3 D2 A4 D3 A5 B2 A2 A1

LEVEL PROBE

(SHORT) t° LEVEL PROBE

(LONG)

120V AC 2 WIRE

120/208V AC 3 WIRE

120/240V AC 3 WIRE

SINGLE PHASE

29077.0028C 02/14 ©2013 BUNN-O-MATIC CORPORATION

P1, P2, &

P3 ARE

PINS OF A

POLARIZED

THREE-PIN

CONNECTOR.

BREW STATION

LEFT FRONT

LEFT REAR

TOP FRONT

TOP REAR

RIGHT FRONT

RIGHT REAR

START BREW

LEFT HIDDEN

RIGHT HIDDEN

“DIGITAL”

“BREWER”

“CONTROL”

CONTROL SWITCH ASSY CODES

2 WARMERS

ON LEFT

A3

2 WARMERS

ON TOP

A3

2 WARMERS

ON RIGHT

A3

A4

B1

B2

D1

D2

D3

A2

A1

A5

A6

A5

A6

A4

B1

B2

D1

D2

D3

A4

B1

B2

D1

D2

D3

Page 11 39132.3 021914

Plain White 20# Bond Paper

Black Ink

Finished Size: 11" x 17"

~100%

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement