6876 Operating Instructions

6876 Operating Instructions
Digital Stand-On
Sit-Down Scale
Models 6876 & 6876KGEU
Operating Instructions
0065-M481-O1 Rev C
05/13
CARDINAL SCALE MFG. CO.
PO BOX 151  WEBB CITY, MO 64870
PH (417) 673-4631  FAX (417) 673-5001
www.detectoscale.com
Technical Support:
Ph: 866-254-8261
 [email protected]
0065-M481-O1
Rev C  6876
& 6876KGEU
Printed in USA
1
2
0065-M481-O1 Rev C  6876 & 6876KGEU
FCC COMPLIANCE STATEMENT
This equipment generates uses and can radiate radio frequency and if not installed and used
in accordance with the instruction manual, may cause interference to radio communications.
It has been tested and found to comply with the limits for a Class A computing device
pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable
protection against such interference when operated in a commercial environment. Operation
of this equipment in a residential area may cause interference in which case the user will be
responsible to take whatever measures necessary to correct the interference.
You may find the booklet "How to Identify and Resolve Radio TV Interference Problems"
prepared by the Federal Communications Commission helpful. It is available from the U.S.
Government Printing Office, Washington, D.C. 20402. Stock No. 001-000-00315-4.
PROPER DISPOSAL
When this device reaches the end of its useful life, it must be properly disposed of. It must not
be disposed of as unsorted municipal waste. Within the European Union, this device should
be returned to the distributor from where it was purchased for proper disposal. This is in
accordance with EU Directive 2002/96/EC. Within North America, the device should be
disposed of in accordance with the local laws regarding the disposal of waste electrical and
electronic equipment.
It is everyone’s responsibility to help maintain the environment and to
reduce the effects of hazardous substances contained in electrical and
electronic equipment on human health. Please do your part by making
certain that this device is properly disposed of. The symbol shown to the
right indicates that this device must not be disposed of in unsorted
municipal waste programs.
COPYRIGHT
All rights reserved. Reproduction or use, without expressed written permission, of editorial or
pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to
the use of the information contained herein.
DISCLAIMER
While every precaution has been taken in the preparation of this manual, the Seller assumes
no responsibility for errors or omissions. Neither is any liability assumed for damages resulting
from use of the information contained herein. All instructions and diagrams have been
checked for accuracy and ease of application; however, success and safety in working with
tools depend to a great extent upon the individual accuracy, skill and caution. For this reason
the Seller is not able to guarantee the result of any procedure contained herein. Nor can they
assume responsibility for any damage to property or injury to persons occasioned from the
procedures. Persons engaging the procedures do so entirely at their own risk.
Serial Number_______________________
Date of Purchase ____________________
Purchased Form_____________________
PRECAUTIONS
Before using this instrument, read this
manual and pay special attention to all
"NOTIFICATION" symbols:
___________________________________
___________________________________
IMPORTANT
RETAIN THIS INFORMATION FOR FUTURE USE
0065-M481-O1 Rev C  6876 & 6876KGEU
1
DIGITAL STAND-ON / SIT-DOWN SCALE
Thank you for purchasing our Model 6876 (6876KGEU) Digital Stand-On / Sit-Down Scale.
It has been manufactured with quality and reliability at our factory in Webb City, MO USA.
Your scale has been tested before leaving our factory to insure accuracy and dependability for
years to come.
This manual is provided to guide you through the operation of your scale. Please read it
thoroughly before attempting to operate your scale and keep it handy for future reference.
SPECIFICATIONS
Model 6876
600 lb x .2 lb (270 kg x .1 kg)
24” x 24” (61cm x 61cm) with non-slip rubber mat
Six digit, Seven segment, 0.7 inch (17.8 mm) high LCD
6 “AA” size Alkaline, Ni-Cad or NiMH batteries (not included) OR an
optional 100 to 240 VAC 50/60Hz 12 VDC 1A wall plug-in UL/CSA
listed AC power supply (Cardinal part number 6800-1045).
Keyboard ................. Membrane type with 5 keys, On/Off, Lock/Release, Units, Zero,
BMI/Enter and 4 directional arrows
Capacity ...................
Platform Size ...........
Display .....................
Power ......................
Model 6876KGEU
Capacity ................... 270 kg x .1 kg
Platform Size ........... 24” x 24” (61cm x 61cm) with non-slip rubber mat
Display ..................... Weight: Five digit, seven segment, 1/2" high LCD
Height: Four digit, seven segment, 3/8" high LCD
Power ...................... 6 “C” cell Ni-Cad or NiMH batteries (not included) OR an optional 100
to 240 VAC 50/60Hz 12 VDC 1A wall plug-in UL/CSA listed AC power
adapter (Cardinal part number 6800-1045)
Keyboard ................. Membrane type with 19 keys, On/Off, Lock/Release, Units, Zero,
Net/Gross, Tare ID/Height, Print/Enter and 0-9 Numeric Keys
UNPACKING INSTRUCTIONS






Remove staples or cut along bottom of carton. Lift carton off pallet.
Check for any damage incurred in shipping. If scale has been damaged, place a claim with
the carrier. It is the responsibility of the purchaser to file all claims for any damages or loss
incurred during transit. Use the original carton and shipping material to return the scale.
Cut packing straps securing scale to pallet.
To remove scale from pallet, at the back of the scale lift up with equal force from the
column and at the platform base near the wheels on the scale. Set gently on floor.
Remove all plastic wrapping, foam fillers and cardboard material from the scale.
Remove and unpack the AC power adapter, if the scale was ordered with this option.
CARE AND CLEANING OF SCALE






2
DO NOT subject the platform to sudden shocks.
DO NOT spray water directly on the display.
DO avoid areas where the scale might be exposed to moisture.
DO NOT use abrasive cleaners on this instrument.
DO NOT use acetone or other volatile solvents for cleaning.
DO clean the scale using a damp soft cloth and mild detergent.
0065-M481-O1 Rev C  6876 & 6876KGEU
OPERATING INSTRUCTIONS
Model 6876 with 750 Indicator
(Shown with Armrest and Seat in Stand-On Position)
Flip-Up
Armrests
Model 750
Indicator
Optional
Power
Supply
Module
Flip-Up
Seat
Platform
1. Install six (6) “AA” size batteries or if ordered with the scale, plug the small connector end
of the power supply cord into the power jack located in the bottom right corner at the back
of the indicator, then plug the power supply module into an appropriate power receptacle.
NOTE! DO NOT connect a power supply to the indicator if Alkaline batteries are installed.
2. Install the indicator on the scale bracket and then connect the load cell cable.
NOTE! For more information on installing the batteries (or the power supply
module), mounting the indicator on the scale bracket and connecting the load
cell cable, refer to the 750 Owner’s Manual, 8555-M260-O1.
3. Place the scale on any hard, level, flat surface or low-cut carpet.
4. With no weight on the scale, press the [ ON/OFF ] key. After a second or so the display
should indicate a zero weight with the ZERO annunciator turned on. If the display does
not indicate zero, press the [ ZERO ] key to zero the weight display.
5. When using as a Stand-On scale (Armrest and Seat in the upright position), have the
patient step on the scale and remain motionless for several seconds until the scale display
shows their weight.
6. If using the scale as a Sit-Down scale (Armrest and Seat in the down position), set the
patient on the scale seat and have them remain motionless for several seconds until the
scale display shows their weight.
7. To re-zero the scale, remove the patient from the scale and press the [ ZERO ] key.
0065-M481-O1 Rev C  6876 & 6876KGEU
3
OPERATING INSTRUCTIONS, CONT.
Model 6876KGEU with 758CSV Indicator
(Shown with Armrest and Seat in Sit-Down Position)
Model 758CSV
Indicator
Flip-Up
Armrests
Optional
Power
Supply
Module
Flip-Up
Seat
Platform
1. Install six (6) “C” size (Ni-Cad or NiMH only) batteries or if ordered with the scale, plug the
small connector end of the power supply cord into the power jack located on the back of
the indicator, then plug the power supply module into an appropriate power receptacle.
2. Install the indicator on the scale bracket and then connect the load cell cable.
NOTE! For more information on installing the batteries (or the power supply
module), mounting the indicator on the scale bracket and connecting the load
cell cable, refer to the 758CSV Owner’s Manual, 8555-M433-O1.
3. Place the scale on any hard, level, flat surface or low-cut carpet.
4. With no weight on the scale platform, press the [ ON/OFF ] key. After a second or so the
display should indicate a zero weight with the ZERO annunciator turned on. If the display
does not indicate zero, press the [ ZERO ] key to zero the weight display.
5. When using as a Stand-On scale (Armrest and Seat in the upright position), have the
patient step on the scale and remain motionless for several seconds until the scale display
shows their weight.
6. If using the scale as a Sit-Down scale (Armrest and Seat in the down position), set the
patient on the scale seat and have them remain motionless for several seconds until the
scale display shows their weight.
7. To re-zero the scale, remove all weight from the platform and press the [ ZERO ] key.
4
0065-M481-O1 Rev C  6876 & 6876KGEU
ERROR and STATUS DISPLAYS
Model 6876 (750 Indicator)
Display
Meaning
-Err-OF-
General error, invalid keypad entry was attempted.
-trL-UnS-
Indicates an attempt to zero a weight outside scale zero range.
CALib
AdErr
ErrAL
ErrAH
OCAP
OFF
Indicates calibration is necessary.
Attempting to display a negative number greater than –9,999 or a
positive number greater than 99,999.
Motion is present when indicator is attempting to perform one of the
following operations: Power Up Zero or Zero Weight Display.
Consult your scale service representative.
Scale weight exceeds scale capacity.
Displayed to indicate indicator is turning off.
Model 6876KGEU (758CSV Indicator)
Display
Meaning
-Err-OF-
General error, invalid keypad entry was attempted.
-trL-
Indicates an attempt to zero a weight outside scale zero range.
(See Four Percent Zero Tracking Range Limit).
-UnS-
Motion is present when indicator is attempting to perform one of the
following operations: Power Up Zero or Zero Weight Display
CALib
AdErr
ErrA
ErrAL
ErrAH
EE Err
OCAP
OFF
Attempting to display a negative number greater than –9,999 or a
positive number greater than 99,999
Indicates calibration is necessary.
Consult your scale service representative.
Scale weight exceeds scale capacity
Displayed to indicate indicator is turning off.
0065-M481-O1 Rev C  6876 & 6876KGEU
5
PART IDENTIFICATION
Tighten Bolts
Securely
Load Cell and
Foot Mounting
Detail
6
0065-M481-O1 Rev C  6876 & 6876KGEU
PART IDENTIFICATION, CONT.
0065-M481-O1 Rev C  6876 & 6876KGEU
7
PART IDENTIFICATION, CONT.
See Load Cell and Foot
Mounting Detail on Page 6
8
0065-M481-O1 Rev C  6876 & 6876KGEU
PART IDENTIFICATION, CONT.
0065-M481-O1 Rev C  6876 & 6876KGEU
9
PART IDENTIFICATION, CONT.
ITEM #
QTY
PART NUMBER
1
1
0065-D450-0A
BASE WELDMENT
2
1
0065-D451-0A
UPPER FRAME WELDMENT
3
2
0065-C452-0A
ARM WELDMENT
4
1
1930-C451-08
J-BOX COVER
5
1
0065-C453-08
MAT, RUBBER
6
4
0065-B454-08
AXLE 5/16 DIA x 2.125
7
-
-
-
8
2
0065-C414-08
SEAT, PADDED
9
1
0065-C232-0A
CROSS TUBE ASSY
10
1
0065-C419-08
SEAT, SUPPORT
11
2
6540-1098
CAP PLUG 1” x 2”
12
-
-
-
13
2
6013-0433
NUT ACORN 10-30 THREADLOCK SS
14
1
3502-C205-0A
PC BRD ASSY
15
2
6021-0695
SCW MACH #6-32 x .5 ZP
16
2
6680-0138
SPACER NYLON #6 x .187
17
4
LFB-250M
LOAD CELL
18
4
0065-B108-08
ALUM FOOT
19
8
6021-0106
SCW PAN HEAD #6-32 X 3/8 S.S. TYPE F PHIL DR
20
4
6540-1122
RUBBER FOOT
21
4
1930-B205-08
SHIM
22
8
399R1048
PUSH NUT
23
2
6540-1205
WHEEL 4” DIA
24
1
593GR986
SERIAL TAG
25
5
0033-B110-08
DISK UHMW
26
2
6680-1044
GROMMET
27
1
6021-1454
SCW HEX HEAD 1/4-20 x 3/4”
28
1
6024-0003
WASHER 1/4”
29
1
391RV204
NUT ELASTIC STOP 1/4-20
30
4
6007-0051
SCW HEX HEAD 3/8-16 x 2”
10
DESCRIPTION
0065-M481-O1 Rev C  6876 & 6876KGEU
PART IDENTIFICATION, CONT.
ITEM #
QTY
31
4
6013-0070
NUT ELASTIC STOP 3/8-16
32
2
6021-1263
SCW TRUSS HEAD #10-32 x 1 1/2”
33
REF
750
INDICATOR FOR 6876
34
4
6024-1045
WASHER FLAT TEFLON
35
2
6540-0030
GRIP FOAM
36
1
0065-B403-0A
INDICATOR CABLE
37
4
6021-0665
SCW PAN HEAD #6-32 x 3/8”
38
24
6021-1509
SCW PAN HEAD #8 x .75 PHIL DRV Z/P
39
4
6021-1105
SCW PAN HEAD #12 x 1.75
40
8
6021-2063
SCW SOC HEAD 3/8-24 x 1”
41
1
0033-B162-08
758CSV INDICATOR MOUNTING
42
REF
758CSV
INDICATOR FOR 6876KEGU
43
1
6680-1043
GROMMET
44
-
-
-
46
-
-
-
46
-
-
-
47
2
6021-0981
SCW HEX HEAD #10 x 3/4” TYPE B
48
-
-
-
49
8
6024-0009
WASHER FLAT 3/8”
50
2
6540-1099
CAP PLUG 1” x 1 1/2”
51
1
6540-1070
GRIP FOAM (CUT IN HALF)
52
1
0065-C428-0A
SEAT BOTTOM COVER
53
2
6540-1094
BUMPER
54
3
6680-0164
GROMMET .43 THK x .25 I.D. FOR 1/4” PANEL
55
1
6690-0001
LEVEL, BULLSEYE
56
A/R
6560-1068
EXPOXY
57
1
0044-B315-0A
750 INDICATOR MOUNTING
6800-1045
OPTIONAL AC ADAPTER: 100-240VAC/12VDC @ 1A

PART NUMBER
DESCRIPTION
 NOT SHOWN
0065-M481-O1 Rev C  6876 & 6876KGEU
11
STATEMENT OF LIMITED WARRANTY
Detecto Scale warrants its equipment to be free from defects in
material and workmanship as follows: Detecto warrants to the
original purchaser only that it will repair or replace any part of
equipment which is defective in material or workmanship for a period
of one (1) year from date of shipment. Detecto shall be the sole
judge of what constitutes a defect.
During the first ninety (90) days Detecto may choose to supply all
necessary replacement parts and service during normal weekday
working hours at no charge to the buyer.
After the first ninety (90) days Detecto will supply parts and
service at the job site provided the owner agrees to pay the Dealer
for all travel time, including mileage and test equipment, as well as
any expenses incurred over the direct labor of the technician at the
job site. This limited warranty honors only labor performed by
Detecto authorized dealers.
This warranty does not apply to peripheral equipment not
manufactured by Detecto; this equipment will be covered by certain
manufacturer’s warranty only.
This warranty does not include replacement of expendable or
consumable parts. This does not apply to any item which has
deteriorated or damaged due to wear, accident, misuse, abuse,
improper line voltage, overloading, theft, lightning, fire, water or acts
of God, or due to extended storage or exposure while in purchaser’s
possession. This warranty does not apply to maintenance service.
Purchased parts will have a ninety (90) day repair or replacement
warranty only.
Detecto may require components be returned to the factory; they
must be properly packed and shipping charges prepaid. A return
authorization number must be obtained for all returns and marked on
the outside of all returned packages. Detecto accepts no
responsibility for loss or damage in transit.
12
0065-M481-O1 Rev C  6876 & 6876KGEU
STATEMENT OF LIMITED WARRANTY
Conditions Which Void Limited Warranty
This warranty shall not apply to equipment which:
A.) Has been tampered with, defaced, mishandled or have had
repairs and modifications not authorized by Detecto.
B.) Has had serial number altered, defaced, or removed.
C.) Has not been grounded according to Detecto’s recommended
procedure.
Freight Carrier Damage
Claims for equipment damaged in transit must be referred to the
freight carrier in accordance with freight carrier regulations.
This warranty sets forth the extent of our liability for breach of any
warranty or deficiency in connection with the sale or use of the
product. Detecto will not be liable for consequential damages of any
nature, including but not limited to, loss of profit, delays or expenses,
whether based on tort or contract. Detecto reserves the right to
incorporate improvements in material and design without notice and
is not obligated to incorporate improvements in equipment
previously manufactured.
The foregoing is in lieu of all other warranties, express or implied
including any warranty that extends beyond the description of the
product including any warranty of merchantability or fitness for a
particular purpose. This warranty covers only those Detecto
products installed in the forty-eight (48) contiguous continental
United States.
Ph. (800) 641-2008
E-mail: [email protected]
203 E. Daugherty
Webb City, MO 64870
0065-M481-O1 Rev C  6876 & 6876KGEU
02/06
Printed in USA
D268-WARRANTY-DET
13
14
0065-M481-O1 Rev C  6876 & 6876KGEU
Was this manual useful for you? yes no