GEN7000LP 7000 Surge Watts / 6000 Running Watts PORTABLE GENERATOR

Add to my manuals
27 Pages

advertisement

GEN7000LP 7000 Surge Watts / 6000 Running Watts PORTABLE GENERATOR | Manualzz

0201308

GEN7000LP

7000 Surge Watts / 6000 Running Watts

ELECTRIC START LPG LIQUID PROPANE GAS

PORTABLE GENERATOR

INSTRUCTION MANUAL

READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.

This manual provides important information on proper operation & maintenance. Every effort has been made to ensure the accuracy of this manual. These instructions are not meant to cover every possible condition and situation that may occur. We reserve the right to change this product at any time without prior notice.

IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE,

DO NOT OPERATE THIS PRODUCT!

DO NOT RETURN THIS PRODUCT TO THE RETAILER - CONTACT CUSTOMER SERVICE.

If you experience a problem, have questions or need parts for this product, visit our website http://www.buffalotools.com or call Customer Service at

1-866-460-9436

, Monday-Friday,

8 AM - 4 PM Central Time. A copy of the sales receipt is required.

FOR CONSUMER USE ONLY – NOT FOR PROFESSIONAL USE.

KEEP THIS MANUAL, SALES RECEIPT & APPLICABLE WARRANTY FOR FUTURE

REFERENCE.

SEEK THE ADVISE OF A LICENSED ELECTRICIAN FOR 120V / 240V WIRING

Model GEN7000LP 7000 Surge Watts / 6000 Running Watts

This unit is a LPG driven generator.

FEATURES:

• 7000 Surge Output

• 6000 Running Watts

• 120/240 Volt Operation

• 13 HP Engine, 4 Stroke OHV

• Air Cooled

• AVR Automatic Voltage Regulation

• Electric and Recoil Start

• Low Oil Shut Off

• Spark Arrestor

• UL Listed Electrical Components

• Full Power Panel

• Engine Shut Off Switch

• 1-12V DC Outlet

• 4-120V Outlets

• 1- 240V Outlet

• EPA – approved

• Run time = 8 hrs @ 50% load per 20 lbs of LP fuel

• Battery Not Included

(A 12 Volt motorcycle battery no larger than 7 1/4" length, 6 1/2" height, and 3" width is required for electric start of this generator.

(The ideal battery required is 7 1/8” L x 6” H x 3’W, 130 Min CCA Cold Cranking Amps)

Comparable brands/models are: Yuasa: YB9A-A, YB9-B or YB9L-B, Delco: CB9A-A, NAPA: 740-1872, 740-1858, 740-1837

Sears: 44043, 44356, 44045, Generic brand SLA-12V22

• Fuel type - Liquid Propane Gas Only (also commonly referred to as LP, LPG and Propane)

• Decibel Rating < 80 db

• If you are using a generator above sea level, the generator may not function properly because of air flow getting through the mixer.

• Propane Tank Not Included

• If you want to use a propane tank larger than 20 lbs, call Customer Service for details at 866-460-9436.

THIS ENGINE MEETS U.S. EPA EMISSION STANDARDS UNDER 40 CFR 1054.625 .

The emission-related warranty is valid for two (2) years. Keep the purchase receipt and mail in the product registration card for proof of purchase.

NB Corp limits emission-related warranty repairs to authorized service centers for owners located within 100 miles of an authorized service center.

For owners located more than 100 miles from an authorized service center, NB Corp will, in its sole discretion, either pay for shipping costs to and from an authorized service center, provide for a service technician to come to the owner to make the warranty repair, or pay for the repair to be made at a local non-authorized service center. The provisions of this paragraph apply only for the contiguous states, excluding the states with high-altitude areas identified in 40 CFR part 1068, Appendix III.

To exercise this warranty, DO NOT RETURN TO RETAILER. Instead, call Customer Service toll free at 1-866-460-9436 (email address [email protected]) and you will be instructed on where to take the engine for warranty service. Take the generator and proof of purchase (your receipt) to the repair facility recommended by the Customer Service Representative. The warranty does not extend to generators damaged or affected by fuel contamination, accidents, neglect, misuse, unauthorized alterations, use in an application for which the product was not designed and any other modifications or abuse.

1 YEAR LIMITED WARRANTY (30 Day Limited Warranty for Commercial and Rental Purpose)

Generators are warranted to be free from defects in materials and workmanship for a period of 1 year from date of original purchase. NB Corp. is not liable for any indirect, incidental or consequential damages from the sale or use of this product. Any implied warranties are limited to 1 year as stated, or as otherwise stated, in this written limited warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages. Some states do not allow limitation on the length of an implied warranty. NB Corp will repair or replace, at its discretion, any part that is proven to be defective in materials or workmanship under normal use during the 1 year warranty period. Warranty repairs or replacements will be made without charge for parts or labor. Parts replaced during warranty repairs will be considered as part of the original product and will have the same warranty period as the original product. This warranty gives you specific legal rights, and you may have other rights that vary from state to state.

This warranty gives you specific legal rights, and you may have other rights that vary from state to state.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 2

TABLE OF CONTENTS

RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS .............................................................................................. 4

PACKAGE CONTENTS

PACKAGE CONTENTS .......................................................................................................................................... 9

COMPONENTS .................................................................................................................................................... 10

PREPARING THE GENERATOR FOR USE ................................................................................................................... 12

Using This Generator For The First Time ............................................................................................................. 12

Step 1 – Add Oil ........................................................................................................................................... 12

Step 2 – Connect Fuel ................................................................................................................................. 13

Step 3 – Ground The Generator ................................................................................................................... 14

Subsequent Use Of This Generator ...................................................................................................................... 14

Step 1 – Verify Oil Level ............................................................................................................................... 14

Step 3 – Ground The Generator ................................................................................................................... 15

STARTING THE GENERATOR ....................................................................................................................................... 15

USING THE GENERATOR ............................................................................................................................................. 16

AC Usage ............................................................................................................................................................. 16

DC Usage ............................................................................................................................................................. 18

STOPPING THE GENERATOR ...................................................................................................................................... 18

MAINTENANCE/CARE .................................................................................................................................................... 19

Recommended Maintenance Schedule ................................................................................................................ 19

Cleaning The Generator ....................................................................................................................................... 19

Checking The Oil Level ......................................................................................................................................... 19

Changing/Adding Oil ............................................................................................................................................. 20

Air Filter Maintenance ........................................................................................................................................... 21

Spark Plug Maintenance ....................................................................................................................................... 21

STORAGE/TRANSPORT PROCEDURES ...................................................................................................................... 22

TROUBLESHOOTING ..................................................................................................................................................... 22

SPECIFICATIONS ........................................................................................................................................................... 23

PARTS DIAGRAM .......................................................................................................................................................... 24

PARTS LIST .................................................................................................................................................................... 25

PORTABILITY KIT INSTALLATION ................................................................................................................................ 28

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 3

RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS

What You Need to Know About Safety Instructions

Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when operating or cleaning tools and equipment.

Always contact your dealer, distributor, service agent or manufacturer about problems or conditions you do not understand.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.

The electrician should use the 120V / 240V Outlet diagram below and on the Wiring Diagram page 27.

SEEK THE ADVISE OF A LICENSED ELECTRICIAN FOR 120V / 240V WIRING

Legal Requirements:

Federal and/or State Occupational Safety and Health Administration (OSHA) regulations, local codes, and/or ordinances may apply to the intended use of this generator. Consult a qualified electrician, electrical inspector, and/or the local agency having jurisdiction. Some areas require generators to be registered with local utility companies. Additional regulations may apply if this generator will be used at a construction site.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 4

IMPORTANT SAFETY INSTRUCTIONS

STOP!

Before using this generator and if you have any questions regarding the hazard and safety notices listed in this manual and/or on this generator, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time.

Carbon Monoxide Gas:

When in operation, the exhaust from this generator contains poisonous carbon monoxide gas. Carbon

monoxide gas is both odorless and colorless AND may be present even if you do not see or smell gas. Breathing this poison gas can

lead to headaches, dizziness, drowsiness, loss of consciousness and eventually death.

• Use this generator ONLY outdoors in non-confined areas.

• Keep at least several feet of clearance on all sides to allow proper ventilation for this generator.

Chemicals:

According to the State of California, the exhaust from this generator contains chemicals known to cause cancer, birth

defects, or other reproductive harm.

Propane (LPG):

This generator may emit highly flammable and explosive vapors, which can cause severe burns or even death. A

nearby open flame can lead to an explosion even if not directly in contact the fuel.

• Do not operate this generator near open flame.

• Always operate this generator on a firm, level surface.

This fuel is highly flammable and explosive. Handling fuel can result in serious injury or burns.

• Before starting the generator, inspect your LPG tank valve for damage or leaks, attach only approved tanks that have been properly filled by an approved station. DO NOT light or smoke cigarettes.

Replace the hose at the first sign of a leak or if age-cracking becomes apparent.

• Always handle propane fuel and generator outdoors.

• Before transporting, turn the fuel valve to the "off" position and disconnect the spark plug.

Powerful Voltage:

This generator produces powerful voltage, which can result in electrocution.

• ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual).

• Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER connect a building electrical system to this generator without a qualified electrician. Doing so voids your warranty. Such connections must isolate generator power from utility power and comply with local electrical laws and codes. Failure to comply can create a back feed into utility lines creating an electrocution hazard, which may result in serious injury or death to utility workers. Such a back feed may cause this generator to explode, burn and create fires when utility power is restored.

• Do not use this generator in wet conditions (rain, snow, active sprinkler system, wet hands, etc.). Always keep this generator dry and operate it with dry hands.

• Do not touch bare wires or outlets (receptacles).

• Do not allow children or non-qualified persons to operate this generator.

High Temperatures:

This generator produces heat when in operation. Temperatures near the exhaust can exceed 150 Degrees

Fahrenheit (65 Degrees Celsius).

• Do not touch hot surfaces. Observe all warning placards on this generator denoting hot surfaces.

• Allow this generator to cool for several minutes after use before touching the engine, muffler or other areas that are hot during operation and before storing indoors.

• Hot exhaust may ignite some materials. Keep flammable materials away from this generator.

• Keep at least several feet of clearance on all sides of this generator during operation. Do not enclose this generator in any structure.

Usage:

Avoid the use of extension cords if possible. If you choose to use them, be sure they are sized adequately to handle the flow of electricity. An undersized cord can overheat, short out and cause a fire.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 5

Usage:

Misuse of this generator can damage it or shorten its life.

• Use this generator only for its intended purpose.

• Operate this generator only on a dry, level surface.

• Allow this generator to run for several minutes before connecting any electrical devices.

• Promptly turn off any malfunctioning devices and disconnect them.

• Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator.

• Do not turn on electrical devices until after they are connected to this generator.

• Turn off all connected electrical devices before stopping this generator.

Flammable liquid gas under pressure. Can form explosive mixtures with air. May cause frostbite. In Case Of Inhalation: Persons suffering from lack of oxygen should be removed to fresh air. If victim is not breathing, administer artificial respiration. If breathing is difficult, administer oxygen. Obtain prompt medical attention. In Case Of Eye Contact: Contact with liquid or cold vapor can cause freezing of tissue. Gently flush eyes with lukewarm water. Obtain medical attention immediately. In Case Of Skin Contact: Contact with liquid or cold vapor can cause frostbite. Immediately warm affected area with lukewarm water not to exceed 105°F (40°C). Fire And Explosion Hazards: Propane is easily ignited. It is heavier than air, therefore, it may collect in low areas or travel along the ground where an ignition source may be present. Pressure in a container can build up due to heat, and it may rupture if pressure relief devices should fail to function. Storage: Cylinders should be stored upright with valve protection cap in place and firmly secured to prevent falling or being knocked over. Protect cylinders from physical damage; do not drag, roll, slide or drop. Use a suitable hand truck for cylinder movement. Post "No Smoking or Open Flames" signs in the storage areas.

There should be no sources of ignition. All electrical equipment should be explosion proof in the storage and use areas. Storage areas must meet national electric codes for class 1 hazardous areas.

Propane smells like rotten eggs, a skunk’s spray, or a dead animal. IF YOU SMELL GAS- NO FLAMES OR SPARKS! Immediately put out all smoking materials and other open flames. Do not operate lights, appliances, telephones, or cell phones. - Flames or sparks from these sources can trigger an explosion or a fire.

WHAT IS CARBON MONOXIDE (CO)?

You can’t taste or smell CO, but it is a very dangerous gas. High levels of CO can come from appliances that are not operating correctly, or from a venting system or chimney that becomes blocked. CO CAN BE DEADLY! High levels of CO can make you dizzy or sick. In extreme cases,

CO can cause brain damage or death.

Symptoms of CO poisoning include: headache, dizziness, fatigue, shortness of breath, and nausea.

IF YOU SUSPECT CO IS PRESENT, ACT IMMEDIATELY!

1. If you or a family member shows physical symptoms of CO poisoning, get everyone out of the building and call 911 or your local fire department.

2. If it is safe to do so, open windows to allow entry of fresh air, and turn off any appliances you suspect may be releasing CO.

3. If no one has symptoms, but you suspect that CO is present, call your propane retailer or a qualified service technician to check CO levels and your propane equipment.

Usage:

Consult a physician(s) before using this generator if using a pacemaker. Electromagnetic fields in close proximity to a heart pacemaker could cause a pacemaker to malfunction or fail. Caution is necessary when near the engine’s recoil starter.

Usage:

Prolonged exposure to high noise levels can be hazardous to hearing. Always wear ANSI-approved hearing protection when operating or working around the generator when it is running.

Usage:

This generator is not intended to power sensitive electronic equipment such as TVs, DVD players, stereos, desktop

computers or laptop computers without the use of an appropriate line conditioner and/or surge protector (both not included).

Sensitive electronic equipment should be operated on approved inverter type generators or pure sine wave generators. For additional information consult the devices operation manual or call customer service at 1-866-460-9436 Monday - Friday, 8 AM - 4 PM Central Time.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 6

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 7

In addition to the previously described safety information, familiarize yourself with all safety and hazard placards on this generator.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 8

PACKAGE CONTENTS

The following items are supplied with this Model GEN7000LP 7000 Surge Watts / 6000 Running Watts Electric Start Portable LP Generator.

Verify that all items are included.

STOP!

If there are missing items, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for customer service. DO NOT RETURN THIS

GENERATOR TO THE RETAILER.

Item List:

L14-30 plug for connecting 240 Volt electrical devices

Set of 2 DC connector wires for connecting 12 Volt automotive-type batteries

Spark plug wrench

5 Ft. Regulator Hose Kit

(YOU MUST USE THE SUPPLIED REGULATOR FOR SAFE OPERATION)

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 9

GENERATOR COMPONENTS

Observe the locations and functions of the various components and controls of this generator.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 10

WARNING:

YOU MUST USE

THE SUPPLIED

REGULATOR FOR

SAFE OPERATION

To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a length of heavy wire between the ground terminal and the ground source.

Consult with a qualified electrician to ensure compliance with local electrical codes.

The Air-fuel Mixer is not adjustable.Tampering with the governor can damage your generator and your electrical devices, and will void your warranty.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 11

PREPARING THE GENERATOR FOR USE

Using this Generator for the First-Time

STOP!

The following section describes the required steps for preparing this generator for the first use. Failure to correctly perform these steps can damage this generator and/or shorten its life. If still unsure about how to perform any of these steps after reading this section, call

1-866-460-9436 Monday - Friday, 8 AM - 4 PM Central Time for customer service.

If this generator is being used for the first time, the following few steps are required to prepare it for operation:

Step 1 - Add Oil

This generator requires engine oil to function. Engine oil is a major factor affecting engine performance and service life. When new from the package, this generator contains no oil in the engine crankcase. The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 38 fluid oz (1.13 L) for this model GEN7000LP 7000 Surge Watts / 6000 Running Watts Electric Start Portable LPG Generator. Add the correct quantity of oil before operating this generator for the first time. When replenishing oil for subsequent use of this generator, always determine that this generator has the correct quantity of oil.

Model GEN7000LP Oil Capacity

Model GEN7000LP Oil Type Recommended

To add oil:

0.30 Gallon / 1.1 Liter / 38 ounces

High Detergent Motor Oil, SAE10W-30

1. Confirm that this generator is on a level surface.

2. Unscrew the oil filler/dipstick cap from the engine as illustrated in Figure 1.

3. Using a funnel, add high detergent motor oil to fill the engine crankcase to the correct quantity. SAE10W-30 oil is recommended for general, alltemperature use. When the engine crankcase is full, the oil level should reach all the way up to the threads as illustrated in Figure 2.

4. Replace the oil filler/dipstick cap.

Figure 1 - Unscrew the Oil Cap Figure 2 - Add Oil To TOP Of Threads

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 12

Step 2 – Connect Fuel

Sulfur, water, dust, etc. are harmful for engine. If the gas supply source (LPG) contains these harmful elements, user must use filter to remove sulfur, water etc. and clean gas. Otherwise, the engine service lifetime will be shortened.

Connect Propane Gas Supply Source

Step 1: Keep gas supply source closed.

Step 2: Attach one end of Regulator Hose to propane tank, and attach the opposite end of

Regulator Hose kit to fuel line.

Make sure the LPG cylinder is vertical and securely positioned.

Pre-Operation Check List

Step 1 Check that the gas supply source is in good condition. Check that the gas inlet connection is tightly fixed and not leaking.

Step 2 CHOKE VALVE GRIP is at CHOKE (CLOSE) position. The generator may be hard to start if CHOKE VALVE GRIP is at RUN

(OPEN) position.

Step 3 Check if engine oil is full.

Step 4 Make sure GROUND TERMINAL is properly grounded.

Step 5 AC OUTPUT no load connected.

Disconnect all electrical loads from the generator set before starting the engine. The generator may be hard to start if a load is connected.

Step 6 DC OUTPUT no load connected.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 13

Step 3 - Ground the Generator

Failure to properly ground this generator can result in electrocution.

Ground this generator by tightening the grounding nut against a grounding wire as illustrated in Figure 3. A No. 12 AWG (American Wire Gauge) stranded copper wire is generally an acceptable grounding wire. The other end of this grounding wire should be connected to a copper or brass grounding rod that is driven into the earth.

Grounding codes can vary by location. Contact a local electrician for information on grounding regulations for your area.

Subsequent Use of this Generator

Figure 3 - Attaching the Grounding Wire to this Generator

For subsequent uses of this generator after the first use, certain steps still must be completed to prepare it for operation.

IMPORTANT: Be familiar with the procedures described in the previous section titled “Using the Generator for the First Time” of this manual. If not, review this section now.

Step 1 - Verify Oil Level

Even though this generator is equipped with an automatic shutoff to protect it from damage due to low oil, it is important to check the oil level in the engine crankcase before each use to ensure that there is sufficient quantity.

1. Verify that this generator is on a level surface.

2. Unscrew the oil filler/dipstick cap from the engine.

3. With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap.

4. Fully insert the dipstick without screwing the filler/dipstick cap and then remove again. There should be oil on the dipstick. If there is no oil on the dipstick, or oil is visible only at the very end of the dipstick, add oil until the engine crankcase is filled. (See “Changing/Adding Oil” in the

“Maintenance/Care” section of this manual).

5. Confirm that the oil filler/dipstick cap is properly screwed in place when finished verifying the oil level.

NOTE: The oil capacity for this Model GEN7000LP 7000 Surge Watts / 6000 Running Watts Electric Start Portable LPG Generator is 38 oz (US).

Model GEN7000LP Oil Capacity

Model GEN7000LP Oil Type Recommended

0.30Gallon / 1.1 Liter / 38 ounces

High Detergent Motor Oil, SAE10W-30

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 14

Step 3 - Ground the Generator

Failure to properly ground this generator can result in electrocution.

Ground this generator by tightening the grounding nut against a grounding wire as previously illustrated in Figure 3. A generally acceptable grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire. The other end of this grounding wire should be connected to a copper or brass grounding rod that is driven into the earth. Grounding codes can vary by location. Contact a local electrician for information on grounding regulations for your area.

STARTING THE GENERATOR

STOP!

Before starting this generator, confirm that all the steps in the section titled, “Preparing the Generator for Use,” of this manual have been correctly completed. If unsure about how to perform any of these steps, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for customer service.

Disconnect all electrical loads from this generator before attempting to start.

A 12 Volt motorcycle battery no larger than 7 1/4" length, 6 1/2" height, and 3" width is required for electric start of this generator.

(The ideal battery required is 7 1/8” L x 6” H x 3’W, 130 Min CCA Cold Cranking Amps)

Comparable brands/models are:

Yuasa: YB9A-A, YB9-B or YB9L-B

NAPA: 740-1872, 740-1858, 740-1837

Delco: CB9A-A

Sears: 44043, 44356, 44045

The location for the battery is behind the metal plate under the electrical panel. If the electric start feature of this generator will be used, first install the battery using the two included cables (one red and the other black) according to the following procedure:

1. Attach one end of the red cable to the positive terminal on the battery and the other end of the red cable to the celenoid.

2. Attach one end of the black cable to the negative terminal and the other end of the black cable to the bolt on the mounting bracket frame.

Step 1 Open fuel supply source.

Step 2 Turn ENGINE SWITCH at ON position.

Step 3 Move Choke Lever to CHOKE position.

Step 4 For recoil start: Pull the STARTER GRIP slowly until resistance is felt and then pull rapidly. After the engine started, return the STARTER

GRIP gently to prevent damage to the starter or housing. DO NOT allow the starter grip to snap back. Return it slowly by hand.

Step 5 For electric start: Press the button and hold until engine starts. If the engine fails to start within five seconds, release and wait at least

5 seconds before attempting to start the engine again.

Step 6 Turn the CHOKE LEVER to RUN position.

Choke Rod

The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the choke rod manually. Pull the rod out toward CLOSED to enrich the mixture for cold starting

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 15

USING THE GENERATOR

After the engine has been running for several minutes, electrical devices may be connected to this generator.

AC Usage

Electrical devices running on AC current may be connected according to their wattage requirements. The rated (running) and surge wattage for this

Model GEN7000LP 7000 Surge Watts / 6000 Running Watts Electric Start Portable LPG Generator is 6,000 and 7,000, respectively.

Model GEN7000 Rated (Running) Wattage

Model GEN7000 Surge Wattage

6000

7000

The rated (running) wattage corresponds to the maximum wattage a generator can output on a continuous basis.

The surge wattage corresponds to the maximum amount of power a generator can output for a short time. Many electrical devices, such as a refrigerator, require short bursts of extra power for starting and stopping fan motors, etc., in addition to their listed rated wattage. Motorized devices typically require more than their rated wattage for startup. The surge wattage ability of a generator allows for this extra power requirement.

The total running wattage requirement of the electrical devices connected to a generator should not exceed the rated wattage of the generator itself.

To calculate the total wattage requirement of the electrical devices to be connected, look up the rated (running) wattage of each device and add these numbers together to find the total wattage that all of the devices together will draw from the generator. If the total wattage of the selected devices exceeds the rated wattage of the generator, DO NOT connect all of the devices. Select a combination of the electrical devices that will have a total wattage less than or equal to the rated wattage for the generator, i.e., no more than 6000 for this Model GEN7000LP 7000 Surge Watts / 6000

Running Watts Electric Start Portable Generator.

This generator can run at its surge wattage capacity for only a short time. Connect electrical devices requiring a rated (running) wattage equal to or less than the rated wattage of this generator. Never connect devices requiring a rated wattage equal to the surge wattage of a generator.

A device's rated (running) wattage should be listed somewhere on the device itself and/or in its manual. If the wattage specification for a device is not available, the wattage can be calculated by multiplying the Voltage requirement (120 or 240) by the Amperage drawn.

Watts = Volts x Amperes

Or, the wattage required by a device can be estimated by using the following chart (see Figure 7). The chart provides only estimates and it is better to know the exact wattage of each electrical device to be powered by this generator.

Electrical Device

air compressor (1 HP) air compressor (1 - 1/2 HP) airless sprayer (1/3 HP) box fan clock radio AM/FM coffee maker computer w/17 inch monitor deep freezer electric drill (1/2 HP)

DVD/CD player or VCR furnace fan blower (1/2 HP) garage door opener (1/2 HP) hot plate light bulb (75 watt) microwave oven (1000 watt) quartz halogen work light refrigerator/freezer (18 Cu. Ft.) saw - circular (7 1/4 inch) saw - miter (10 inch) saw - reciprocating security system electric stove - single element sump pump television (27 inch color) electric water heater (40 gallon) window air conditioner (10000 BTU) window fan

Rated (Running) Watts Additional Surge Watts

1500

2500

600

300

300

75

1000

1000

800

1500

1800

960

180

1500

800

500

1000

100

800

480

2500

1500

800

500

4000

1200

300

3000

2500

1200

600

0

0

0

500

1000

0

1800

1040

0

0

1200

0

0

1800

600

1300

520

0

0

0

0

1600

1500

Figure 7 - Estimated wattage requirements for common electrical devices.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 16

Connect electrical devices to this generator according to the following procedure:

1. Allow the engine to run for several minutes after it has been started.

2. Confirm that the electrical device is switched off prior to plugging it into this generator.

Connect only electrical devices that are in good working order. Faulty devices or power cords present the risk of electrical shock.

Immediately turn off and disconnect any device that commences to operate abnormally, sluggish or abruptly stops. Determine if the

problem was the device or the rated load capacity of this generator has been exceeded.

NOTE: Plug appliances into the correct outlet. Connect standard 120 Volt, single phase, 60 Hz loads to the 120 Volt outlet. Connect 240/120Volt, single phase, 60Hz loads with a L14-30 plug only to the 240/120 Volt outlet. See Figure 8 for an illustration of these outlets.

Even though this Portable LP Generator GEN7000LP has an overall rated wattage of 6000, do not attempt to draw more than 20 AMPS from

any set of Two receptacles of the 120 Volt outlets. Draws higher than 20 Amps will damage this generator and void the warranty.

3. Make sure AC Reset button is pressed in.

NOTE: While this generator is running, power is available from either the standard 120 Volt outlets or the 240/120 Volt outlet. Both 120 Volts and

240 Volts can be simultaneously drawn from this generator.

4. Turn on the connected electrical devices beginning with the device with the highest rated wattage requirement and then each additional device with the next lower rated wattage requirement.

Do not connect 50Hz or 3-phase loads to this generator.

Output A Set of 2

Receptacles

Output B Set of 2

Receptacles

A

B

Figure 8 - Outlets Available on this Generator: 120V AC (4 each), 240/120 AC (one each) and 12V DC

(one each). Output A Set of 2 Receptacles has max 20 Amps. Output B Set of 2 Receptacles has max 20

Amps. 240V Receptacle has max 30 Amps.

SOME NOTES ABOUT POWER CORDS

Long or thin cords can require more wattage from a generator to power an electrical device. Figure 9 shows the recommended cords according to the power requirement of the electrical device. When using cords that exceed these specifications, allow for the electrical device to have a slightly higher rated wattage requirement.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 17

Device Requirements Max. Cord Length (ft) by Wire Gauge

Amps Watts (120V) Watts (240V) #8 wire #10 wire #12 wire #14 wire #16 wire

2.5

5

7.5

10

15

20

25

30

300

600

900

1200

1800

2400

3000

3600

40 4800

NR = Not Recommended.

600

1200

1800

2400

3600

4800

6000

7200

9600

NR

NR

NR

NR

NR

175

150

125

90

1000

500

350

250

150

125

100

65

NR

600

300

200

150

100

75

60

NR

NR

375

200

125

100

65

50

NR

NR

NR

250

125

100

50

NR

NR

NR

NR

NR

Figure 9 - Maximum Extension Cord Lengths by Power Requirement

DC Usage

The DC outlet is only for recharging 12 Volt automotive-type batteries. Do not connect any other device to this outlet.

Use this generator only for recharging 12 Volt batteries. NEVER attempt to jumpstart a car with this generator.

Failing to use the correct procedure can cause a battery to explode, seriously injuring anyone nearby. Keep heat, sparks, flame and

smoking materials away from the battery.

To connect 12 Volt batteries to the DC outlet:

1. Connect the red charging wire to the positive terminal of the battery and the black charging wire to the negative terminal of the battery.

2. Connect the plug end of the wire to the 12V DC outlet on this generator.

3. Start this generator.

4. When disconnecting, always disconnect the wires from this generator first to avoid a spark.

Storage batteries emit highly explosive hydrogen gas when charged.

Batteries also contain acid, which can cause severe chemical burns.

• Do not allow open flames or cigarettes nearby for several minutes after charging a battery.

• Always wear protective goggles and rubber gloves when charging a battery.

• If battery acid gets on the skin, flush with water.

• If battery acid gets in the eyes, flush with water and immediately call a physician.

• If battery acid is swallowed, drink large quantities of milk and immediately call a physician.

STOPPING THE GENERATOR

To stop this generator:

1. Turn off all connected electrical devices and then unplug them.

2. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator.

3. Turn off the engine switch.

4. Turn the fuel valve to the “off” position.

Allow this generator to cool down before touching areas that become hot during operation.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 18

MAINTENANCE/CARE

Proper routine maintenance of this generator is essential for safe, economical, and trouble-free operation. It will help prolong the life of this generator as well as help reduce air pollution. Perform maintenance checks and procedures according to the schedule in Figure 10.

STOP!

If you have questions about maintenance procedures described in this manual, call 1-866-460-9436 , Monday - Friday, 8 AM - 4 PM Central Time.

Never perform maintenance procedures while this generator is running. Allow this generator to cool before commencing any maintenance

procedures. Keep heat, sparks and flame away.

Improper maintenance and/or failure to correct any problems prior to operating this generator can cause a malfunction which could cause

death or serious injury. Always follow the inspection and maintenance recommendations and schedules in this manual.

Recommended Maintenance Schedule

Engine Oil

Air Filter

Check Level

Replace

Check

Clean

Fuel Filler Cap Clean

Spark Plug Check/Clean

Clean

Each Use Every Month or

Each 20 Hrs

X

X (First Use)

X

Every 3 Months or

Each 50 Hrs

X

Figure 10 - Recommended maintenance schedule

Every 6 Months or

Each 100 Hrs

X

X

X

Every Year or

Each 300 Hrs

X

Cleaning the Generator

Always try to use this generator in a cool dry place. If this generator becomes dirty, the exterior can be cleaned with a damp cloth, soft brush, vacuum and/or pressurized air.

Never clean this generator with a bucket of water and/or a hose as water can get inside and cause a short circuit or corrosion.

Never use gasoline to clean parts of this generator.

Checking the Oil Level

Even though this generator is equipped with an automatic shutoff to protect it from damage due to low oil, it is important to check the oil level in the engine crankcase before each use to ensure that there is a sufficient quantity.

To check the oil level:

1. Verify that this generator is shut down and on a level surface.

2. Unscrew the oil filler/dipstick cap from the engine as illustrated in Figure 11.

3. With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap.

4. Insert the dipstick as if replacing the cap and then remove again. There should be oil on the dipstick. If there is no oil on the dipstick, or oil is visible only at the very end of the dipstick, add oil until the engine crankcase is filled (see “Changing/Adding Oil” in this section of this manual).

5. Confirm that the oil filler/dipstick cap is properly in place when finished verifying the oil level.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 19

Figure 11 - Checking the Oil

Changing/Adding Oil

The oil level in this generator should be checked before each use. (See Figure 10.) When the oil level is low, add oil until the level is sufficient to operate this generator.

The oil capacity for this Model GEN7000LP 7000 Surge Watts / 6000 Running Watts Electric Start Portable LPG Generator engine is 1.2 Qt.

(38 fluid oz.) (1.13 L).

To drain the oil from this generator:

The oil should be changed after the first 20 hours of operation. The oil should then be changed every 6months, or for every 100 hours of use time, or when it has become contaminated with water and/or dirt.

1. Place a bucket underneath this generator to catch oil as it drains.

2. Using a 10 mm hex wrench, unscrew the oil drain plug located on the crankcase underneath the oil filler/dipstick cap as illustrated in Figure 12.

3. Allow all the oil to drain from this generator.

4. Replace the oil drain plug and tighten with a 10 mm hex wrench.

NOTE: Never dispose of used motor oil in the trash, down a drain or on the ground. Put oil in a sealed container and contact your local recycling center or auto garage to arrange oil disposal.

To add oil to the engine crankcase:

1. Confirm that this generator is on a level surface.

2. Unscrew the oil filler/dipstick cap from the engine as illustrated in Figure 11 above.

3. Using a funnel, add high detergent motor oil to fill the engine crankcase to the correct quantity. SAE10W-30 oil is recommended for general use.

When the engine crankcase is full, the oil level should reach the lower lip of the oil filling opening as shown in Figure 13.

Model GEN7000LP Oil Capacity (Qt/fluid oz./L)

Model GEN7000LP Oil Type Recommended

1.2 / 38 / 1.13

High Detergent Motor Oil, SAE10W-30

Figure 12 - Draining Oil Figure 13 - Adding Oil

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 20

Air Filter Maintenance

Occasionally verify that the air filter is free of excessive dirt. The air filter will require more frequent cleaning when operating this generator in extremely dusty areas.

1. Unhinge the clasps at the top and bottom of the air filter cover as shown in Figure 14.

2. Remove the sponge-like elements from the casing.

3. Wipe the dirt from inside the empty air filter casing.

4. Wash the sponge-like elements in household detergent and warm water. Do not use gasoline or a flammable solvent.

5. Allow the sponge-like elements to dry thoroughly.

6. Soak the dry sponge-like elements in engine oil. Squeeze out any excess oil. The engine will smoke during initial startup if too much oil is left in the air filter.

7. Replace the sponge-like elements in the air filter casing (the fine element first) and replace the cover.

Figure 14 - Removing the Air Filter Casing. Figure 16 - Locating the Spark Plug

Spark Plug Maintenance

This LPG Generator is more efficient than traditional gasoline generators. As such, the spark plug on this LPG generator will last longer.

Please contact Customer Service if you have questions regarding the spark plug. (Figure 16)

STORAGE/TRANSPORT PROCEDURES

Never place any type of storage cover on this generator while it is still hot.

When transporting or storing this generator for extended time:

• Allow generator to fully cool before moving it. A hot engine and exhaust system can burn you and ignite some materials.

• Disconnect the battery used for the electric start feature of this generator, first disconnecting the black cable and then the red cable.

• Turn the fuel valve to the “off” position.

• Disconnect the spark plug. (See Figure 16, Locating the spark plug.)

• Do not obstruct any ventilation openings.

• Do not drop or strike this generator while moving it.

• Store this generator in a cool dry area, free of excessive dust.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 21

TROUBLESHOOTING

IMPORTANT: If trouble persists, call our customer help line at 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time.

Symptom

Engine will not start.

Cause

Fuel valve is turned to "closed."

Choke is open.

Propate Tank is out of fuel.

Spark plug is dirty.

Solution

Turn fuel valve to "open."

Close the choke.

Replace propane fuel tank.

Clean spark plug.

Generator runs but does not support all connected electrical devices.

Engine runs but there is no electrical output.

Generator is not on level surface.

Oil is low.

Generator is overloaded.

Short in one of the connected devices.

Air filter is dirty.

Loose wiring harness connnection

Move generator to a level surface to prevent triggering the low oil shutdown.

Add or replace oil.

Reduce draw on generator to within this generator's rated wattage by reducing number of connected electrical devices.

Disconnect any faulty or short-circuited electrical loads.

Clean or replace air filter.

Turn off generator, then check wiring behind control panel and at the end of generator for loose connection. If wires are loose, tighten the screws and/or nuts. Be certain the plug in connectors are pushed together all the way.

Reset button(s) is (are) "off."

Loose wiring harness connnection

Push reset button(s) to "on."

Turn off generator, then check wiring behind control panel and at the end of generator for loose connection. If wires are loose, tighten the screws and/or nuts. Be certain the plug in connectors are pushed together all the way.

Bad connecting wires/cables. Try a different extension cord.

Bad electrical device connected to generator. Disconnect device, try connecting another

Carbon Brushes are worn down device.

Turn off generator, then look at the brush

AVR shorted out or burned out holder at the end of the generator to determine if the brushers are still against the copper bands on the end of the rotor. If they are worn down, replace the 2 wires the same way they came off.

Turn off the generator, then remove the 2 screws at the end of the generator. Look for the burn spots on the back side of the AVR. If there is burn spots, replace the AVR.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 22

SPECIFICATIONS

Model GEN7000LP 7000 Surge Watts / 6000 Running Watts Electric Start Portable LPG Generator

Generator

Brush, Revolving Magnetic Field, Self Exciting, 2-Pole, Single Phase Type

AC Output

Rated Wattage (W)

Surge Wattage (W)

Rated Voltage (V)

Rated Amperage

6000

7000

120/240

25A+25A at 120 V

25 A at 240 V

60

Single

Rated Frequency (Hz)

Phase

DC Output

Voltage (V)

Circuit Breaker Amperage (A)

Engine

Approvals

Engine Model (HP)

Engine Type

Ignition System

Starting System

Continuous Operating Hours

Oil Capacity (SAE10W-30) (fl oz./Qts/L)

12

10

EPA

13

4-stroke OHV single cylinder with forced air cooling system.

Non-contact transistor (T.C.I.)

Recoil & Electric

Run time = 8 hrs @ 50% load per 20 lbs of LPG fuel

38 / 1.2 / 1.13

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 23

PARTS DIAGRAM

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 24

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 25

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 26

PORTABILITY KIT INSTALLATION

The manufacturer recommends that you properly install the Portability Kit when using your generator. Installing the Portability Kit is not required for the GEN7000LP to operate, but is included with the generator purchase.

Figure 1

Figure 2

Figure 3

1. Locate the handle-mounting bracket on the generator frame. (Located on the top right side when looking at the control panel of the generator,

Figure 1). Attached the handle by placing the handle around the outside of the handle-mounting bracket, and aligning the bottom set of holes. Insert a bolt (M8*50) through home on the frame and the handle-mounting bracket, and secure with a nut (M8) and washer.

Insert the bolt pin (M8, which links with cable) into upper hole on the frame when the handle when moving the generator (Figure 2). To lower the handle remove the pin, lower the handle, and replace the bolt pin (Figure 3).

Figure 6

Figure 8

Install the wheel axle into frame (Figure 4), fix with a washer

(φ27*φ16.5*2) and pin (φ3.2*40). Tighten and secure both wheels. (Figure 5)

Figure 5

Figure 7

Install the stabilizing bar (Figure 6) by inserting the bolts (M8x20) through the feet on the stabilizing bar and the generator frame. Tighten the nut (M8) onto bolt. (Figure 7).

BATTERY TRAY INSTALLATION

A battery must be installed before the electric start feature can be used. Disconnect all electrical loads from this generator before installing/changing the battery. First, mount the battery case in the area located next to the starter. Insert the bolts (M6x12) through the frame and tighten the balance cover with the bolt (M6x12) after setting the battery in place. (Figure 8.) Install the battery by using the two cables (one red and the other black) that are attached to the engine. Attach the red/positive cable to the positive terminal on the battery.

Attach the black /negative cable to the negative terminal on the battery. Slide the battery into the battery case.

Use the enclosed rubber strap to secure the battery in place.

GEN7000LP 7000 Surge Watt / 6000 Running Watt Portable LPG Liquid Propane Gas Electric Start Generator Manual 27