TR 635top •

TR 635top •
310 857
TERMINA
1-channel 7 day timer
ion
g to vers
Accordin med
ram
Preprog urrent time
ec
with th er/ winter
m
m
u
s
d
an
e
norm tim
Safety
Information
The connection and installation of electrical
appliances must be performed by a skilled
electrician only. Any intervention into or
modifications to the appliance shall lead to
the lapse of all warranty rights. Comply with
your national regulations and all relevant
safety stipulations.
•
24
Auto
Channel statuses
/ OFF
Service voltage OK
Two flashing dots
Power reserve mode:
Three flashing dots
0
Displayed only when summer/
winter time changeover is
activated
Summer time r
Winter time f
Current days of the week
1 = Monday, 2 = Tuesday, ...
1 2 3 4 5 6 7
MENU
-
+
OK
The decision Yes confirms the
selection or programming
Selection
e.g.: Auto, PROG, ...
Pulse, Cycle
Abort input
1
Decision No means continue
2
3
5
6
Load
Last
TR 635top
Overview per day of
the programmed
switching times
5 = Friday
Display of special functions:
Permanent ON/OFF
Random program active z
Holiday program active h
N
L
First contact
The timer is delivered in so-called sleep mode.
To activate without a service voltage:
Briefly press the Menu key.
Activate with mains voltage:
According to version the timeswitch is already
pre-programmed with the actual time, the weekday, and the changeover setting for Summer /
Winter time, the actual time and status display
appears after selection of the National language.
If the timer is not pre-programmed:
First select your National language and then
enter the actual date and time.
Selection of the national language
Initial operation
Activate the clock,
select the national language
By pressing the
or
key select your
national language.
Store your selection by pressing the
key.
The decision Yes, confirms the
selection or programming.
For programming, viewing, amending or
deleting
First of all read the text display.
Menu selection:
Select by pressing the
Prog key
Confirm by pressing
.
By pressing the
key select the desired menu.
e.g. New, View, Amend or Delete.
Confirm your selection by pressing
.
Set or change: by pressing
or
.
Store by presssing
.
To display the switching times:
In the menu View, press the
key several times.
The decision No, means
continue.
Set or amend by pressing the
or
keys.
According
to version
According
to version
In emergency situations only: Should you press RESET on the timer, all stored data will be deleted. However, the timer will then still display the language last selected and the summer/ winter norm time changeover last selected. Press the RES key with and a pointed object for approx. 1 second.
Lithium,
ap. 4 years
TR 635 0 xxx
230V/240V~
+ 6% - 10% 50 – 60 Hz
Type 1 BSTU
IEC/EN 60730-2-7
power reserve
Attention:
Use only with the
original base
42 memory
locations
Degree of
protection
II EN 60730-1
IP 20 EN 60529
min. – 10° C
to
max. + 50° C
info
Programming the switching time
Formation of day groups
If the same switching times are active on
several days of the week, they occupy just
one memory location. 42 memory locations
are available, e.g. Monday – Friday 7.30 hrs
ON.
Group formation: In answer to the text
question Copy, decide by pressing the
key that the day program should be copied to
another day of the week. The Mixed programming of switching, pulse and cycle
times is allowed.
Switching times for lighting systems, machines,
ventilation systems, alarm systems etc.
MENU
Auto Prog
action
Man
OK
OK
+ OK
+ OK
info
When programming an ON and
OFF switching time, e.g. 9 AM,
a switch-off at 9 AM always
has priority.
Program review:
Following programming the
timer makes a program review
back to midnight and then sets
the correct switching status.
OK OK OK OK
1 Copy 2
3
+ OK
+
+
4
6
7 Memo
5
OK
Example: Switching on the lighting of a sports
hall on Mon., Tues., Thurs., Fri. from 7.30h until 12h.
Programming example:
Select Prog by pressing the
key.
Store your selection by pressing the
key.
Select New by pressing the
or
.
Store your selection by pressing the
key.
Select ON or OFF by pressing
or
.
Store your selection by pressing
.
Set the hours and minutes by pressing the
or
key.
Store selection by pressing
.
To store one day of the week only:
Select weekday by pressing
or
.
Select store by pressing
.
Store by pressing
To copy to other days of the week:
Store copy by pressing
.
Select weekday by pressing
or
.
Store by pressing
To leave out a day of the week, skip by pressing
the
key.
Finally select the store display by pressing
.
Store your selection by pressing
.
Effect of the random program:
The random program causes the timer to
switch between programmed pairs of switches (ON and OFF). The random on an off
times range between approx. 10 mins. and
120 min. The random time always begins
with OFF.
Permanent ON or OFF
random or holiday program
Symbol z flashes when the random program is effective.
Random ON
Random OFF
Example:
Random start
19.30 h ON
Read the text display first of all
In the menu Man, select by pressing the
or
key the function manual, permanent, random or holiday.
Confirm your selection by pressing the
key.
To cancel a function:
Select the function clear.
Store your selection by pressing
.
Via the
automatic menu AUTO only
Example:
Random finish
6.00 h OFF
Effect of the holiday program: The holiday program has the effect that the timer
does not switch on the connected consumer
unit between the programmed start and
finish (stipulation of year, month, day). Start
and finish of the program is always midnight on the day that is programmed.
Example: 25.3. national holiday.
Programming: start 25.3. finish 25.3.
If the holiday program is active, the corresponding channel and
holiday symbol h are displayed flashing on the automatic menu.
Press the two keys
for approx. 1 s
Press both keys for
approx. 2 s
Manual preselection:
Press keys simultaneously
Channel C1 switches alternately ON or OFF.
Symbol
appears.
Manual preselection is corrected again by the stored
program.
Permanent
OFF
●
●
Cancellation of manual preselection/ permanent
switching: Briefly press the keys shown above.
Pulse program
Effect of the pulse program:
The pulse time can be set within the range
1 to 59 seconds.
Symbol
e. g.: for breaktime signals, ventilation systems,
flushing systems, bell controls etc.
flashes as long as the pulse program is active
Example:
Switch off at
17.30 h 15 s
Switch-off delay
Program:
7.00 until 17.30 h
and
pulse at 17.30 h
pulse ON, duration 15 s
Always read the text display first of
all. You will be provided with programming help. Confirm your selection by pressing the
key.
Switch-on delay
Example:
Switch-on at 7.00 h 15 s
Program:
To switch on from
7.00 until 17.30 h
and
pulse, OFF at 7.00 h
pulse duration 15 s
Viewing the pulse times
Only possible in the menu PULSE
Day group formation
If the same pulse switching times are effective on
several days of the week, they occupy one pulse
memory location only, e.g.: Mon., Tues., Wed., Fri.,
pulse time 7.30 h. 32 memory locations are available
for pulse programming.
Cycle program
Effect of the cycle program:
The clocking and pause times can be set separately. The settable times are max. 99 minutes and
59 seconds. The cycle program has the effect that
between two programmed times, day of week
start and day of week finish, the cycle program
is active. The cycle program always begins with a
switch on.
16 memory locations are available to you.
The symbol
is active.
Cyclically recurring time
functions within the scope of a timer,
e.g.: slow flashing indicator, water treatment,
advertisement lighting
flashes when the cycle program
duration
Select by pressing the
pause
Brightness variations at
lighting installations may
arise in the cycling mode.
In this case actions to reduce
these effects have to be
taken (for example reduction of the load or extension
of the cycle time).
More than five switching
operations per minute are
not admissible without
additional EMC interference
measures.
key Cycle.
Store your selection by pressing twice the
Set cycle start by pressing the keys
Example cycle start:
Monday 7.30 h ON
Example cycle finish:
Friday 16.30 h OFF
Store your selection by pressing the
key.
or
.
key.
Set cycle duration (Min./sec.) by pressing the keys
Store your selection by pressing the
Set cycle pause (Min./sec.) by pressing the keys
Viewing the cycle times:
Possible in the menu Cycle only!
N.B.: If two cycle times are programmed in which the start and
finish times overlap, it is always the cycle time that starts first
that is executed.
Example: Cycle time 1, programmed from: Mo to Thu
Cycle time 2, programmed from: Tue to Fri.
Only cycle time 1 is effective, cycle time 2 is not accepted.
or
.
or
.
key.
Store your selection by pressing the
key.
Set cycle finish by pressing the keys
or
Store your selection by pressing the
key.
.
Setting/ correcting the date and time
summer/winter time
Automatic summer/winter time
correction
According to version the timer is preprogrammed ex-works complete with
the change-over. Should you switch off
the automatic facility or wish to alter it,
first of all read the text display.
Select by pressing
or
.
Store by pressing
.
Read the text display first of all.
Select by pressing the
key
or
key.
Store by pressing the
key.
Free Prog to select sum/win changeover other than EUR-GB-USA.
Select sum/win, and after with
sum/win. Store with
.
Select rule FREE – with buttons
or
.
Input month and weeks for sum/win.
Store with
.
E.g. Month = March
Week 4 = fourth week
Week 5 = last week in month
Note: In sum/win free Prog the time
change is set automatically at
sunday 2 AM.
Time change is not available.
TIMEGUARD LTD, Victory Park, 400 Edgware Road London NW2 6ND
Tel. 0181/4508944; Fax: 0181/4525143
PETER WARBURTON PTY. LIMITED, 64 Brittania Road, Castle Hill
NSW 2154, Australia, Tel.: (02) 9899 2908, Fax: (02) 9899 4486
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project