R3 RACK MOUNT CARD CAGE PRODUCT SPECIFICATION

R3 RACK MOUNT CARD CAGE PRODUCT SPECIFICATION
R3
PRODUCT SPECIFICATION
RACK MOUNT CARD CAGE
temporary or intermittent condition. Furthermore, all modules located
within the chassis rack are hot-swappable, so that it is not necessary to
power-down the rack when removing or replacing modules.
Rather than utilizing a switching-mode or linear DC power supply
for providing the operating power to the rack as employed by most
competing designs, the IFS Model R3 Chassis Rack uses a
simple under stressed step-down power transformer,
and all rectification, filtering, and regulation is performed
within each rack mounted module. The use of a step-down
power transformer for the power supply unit results in a
significantly higher MTBF than any switching-mode or linear
DC power supply can provide, as there are no semiconductors,
electrolytic capacitors, etc., to degrade the reliability of the supply. In
addition, the high-reliability transformer power supply and current limiting
built into each module, eliminates the necessity of providing redundant
power supplies within the chassis rack, as the overall system reliability is
still much higher (and less costly) than can be provided with a redundant
power supply design approach.
R3
QUALITY DESIGN
The design approach employed by IFS for equipment mounted
within the model R3 Chassis Rack Unit with Integral 115/230 VAC
Power Supply, provides for the elimination of a single-point failure
in the event of a major fault within any module located within the
chassis rack. This is accomplished through the use of automatic
electronic current limiting within each rack-mountable module,
rather than to provide the current limiting within the power supply
unit which supports the power requirements for equipment located
within the rack. In nearly all competing designs, a major fault within
a module, located within the chassis rack, results in the power supply
unit going into a current limiting condition, and as a result, all of the
modules located within the rack shut down. The R3 Rack design
employed by IFS eliminates this possibility, as only the faulty
module shuts down, and the operation of the other devices within the
rack continues unimpaired. This automatic current limiting
feature is also self-resetting, should the fault or overload be of a
Available at:
www.
• A & E Specifications, (CSI)
• AutoCAD Drawings
• Operation Manuals
• Technical Bulletins
ORDERING INFORMATION
PART
NUMBER
R3
R3-DC-115
R3-24
OPTIONS
DESCRIPTION
19” Rack, 115 VAC Input (includes power supply)
19” Rack, 115 VAC Input (DC Back Plane included)
19” Rack, 24 VDC Input (includes power supply)
R3-48
19” Rack, 48 VDC Input (includes power supply)
R3-230
19” Rack, 230 VAC Input (includes power supply)
R3-CH
19” Rack, No power supply
R3-BP
Blank Panel (1”)
PS-R3
115 VAC Power Supply
PS-R3-24
24 VDC Power Supply
PS-R3-48
48 VDC Power Supply
PS-R3-230
230 VAC Power Supply
.com
International Fiber Systems, Incorporated ■ DESIGN CENTER (888) 999-9IFS or (203) 426-1180
FAX (203) 426-3326 ■ [email protected]
Europe, Middle East, Africa TEL +44(0) 1732 522 777 ■ Asia Pacific TEL +65 6235 2661
Australia TEL +61 2 9836 0600 ■ Latin America TEL (512) 477-8787
R3
TECHNICAL SPECIFICATION
RACK MOUNT CARD CAGE
SPECIFICATIONS
ELECTRICAL & MECHANICAL
Circuit Board:
Size (in./cm.) (LxWxH)
Meets IPC Standard
Rack Mount:
Shipping Weight:
19.0 x 7.0 x 5.25 in., 48.3 x 17.8 x 13.3 cm
< 5 lbs./2.15 kg
Input Voltage:
Power supply
115 VAC (other voltages available)
(to plug-in modules):
# Slots/Spacing
20 VAC C.T. @4.0A
R3:
14 one-inch modules or 7 two-inch modules.
Refer to Data Sheet for each model number
MTBF:
Operating Temp:
> 100,000 hours
-40° C to +74° C, ambient
to verify the required number of slots in the
R3 Card Cage.
Storage Temp:
-40° C to +85° C, ambient
FUSING
ENVIRONMENTAL
1A slow blow (Rack power supply)
(Plug-in modules individually electronically
fused)
AC LINE CORD
Detachable, IEC-connectorized.
Allows easy field replacement or exchange
for various worldwide AC power plug
configurations
MADE IN THE USA
TEL (203)426-1180 ■ FAX (203)426-3326 ■ www.ifs.com ■ [email protected]
16 Commerce Road ■ Newtown, CT 06470
Due to our continued effort to advance technology, product specifications are subject to change without notice.
05/29/03
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project