[MS-16Y1]DK-21606_CB Report

[MS-16Y1]DK-21606_CB Report
Issue Date:
2011-01-12
Page 1 of 1
Report Reference #
ASL10120310
COVER PAGE FOR TEST REPORT
Test Item Description:
Model/Type Reference:
Rating(s):
Standards:
Applicant Name and
Address:
Factory Location(s):
Notebook PC
MS-16Y1
19Vdc, 3.42A or 19Vdc, 4.74A
IEC 60950-1:2005, Second Edition and/or EN 60950-1:2006
PEGATRON CORP
5TH FL, 76, LIGONG ST, BEITOU DISTRICT, TAIPEI 112, TAIWAN
PROTEK (SHANGHAI) LTD
3768 XIU YAN RD KANG QIAO TOWN PU DONG NEW DISTRICT
SHANGHAI CHINA
This Report includes the following parts, in addition to this cover page:
1. Specific Technical Criteria
2. Clause Verdicts
3. Critical Components
4. Test Results
5. Enclosures
a. National Differences (21 pages)
b. Photographs (28 pages)
c. Schematics + PWB (5 pages)
d. Manuals (3 pages)
e. Miscellaneous (7 pages)
All applicable tests according to the above standard(s) have been carried out.
Test results are valid only for the tested equipment.
This Test Report can be reproduced only in whole.
Amendments and corrections can be reproduced only with the original CB Test Report.
Written permission from UL International Demko A/S is required if the test report is copied in part.
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 1 of 50
Report Reference #
ASL10120310
Test Report issued under
the responsibility of:
UL International Demko A/S
TEST REPORT
IEC 60950-1:2005 (2nd Edition) and/or EN 60950-1:2006
Information technology equipment - Safety Part 1: General requirements
Report Reference No .................. :
ASL10120310
Date of issue ................................. :
2011-01-12
Total number of pages .................. :
50
CB Testing Laboratory ............... :
Universal Standard Service, Inc.
Address ......................................... :
8F-1, No. 266, Sec. 1, WenHua 2nd Road, Lin Kou Shiang 244,
Taipei County, Taiwan
Applicant's name ........................ :
Address ......................................... :
PEGATRON CORP
5TH FL, 76, LIGONG ST, BEITOU DISTRICT, TAIPEI 112, TAIWAN
Test specification:
Standard ....................................... :
IEC 60950-1:2005, Second Edition and/or EN 60950-1:2006
Test procedure .............................. :
CB Scheme
Non-standard test method ............ :
N/A
Test Report Form No. ................. :
IECEN60950_1C
Test Report Form originator .......... :
SGS Fimko Ltd
Master TRF ................................... :
2007-06
Copyright c 2006 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is
acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.
If this test Report is used by non-IECEE members, the IECEE/IEC logo shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description .................. :
Notebook PC
Trade Mark .................................... :
Model/Type reference ................... :
Manufacturer ................................. :
MS-16Y1
MICRO-STAR INTERNATIONAL CO., LTD
NO. 69, Li-De St, Jung He city,Taipei Hsieh, Taiwan.
Rating ............................................ :
TRF No. IECEN60950_1C
19Vdc, 3.42A or 19Vdc, 4.74A
UL International Demko A/S
Issue Date:
2011-01-12
Page 2 of 50
Report Reference #
ASL10120310
Testing procedure and testing location:
[x]
CB Testing Laboratory
Testing location / address ............. :
[]
Universal Standard Service, Inc. 8F-1, No. 266, Sec. 1,
WenHua 2nd Road, Lin Kou Shiang 244, Taipei County,
Taiwan
Associated CB Test Laboratory
Testing location / address ............. :
[]
Tested by (name + signature) ....... :
Chia Chang
Approved by (+ signature) ............. :
Andy Cheng
Testing Procedure: TMP
Tested by (name + signature) ....... :
Approved by (+ signature) ............. :
Testing location / address ............. :
[]
Testing Procedure: WMT
Tested by (name + signature) ....... :
Witnessed by (+ signature)............ :
Approved by (+ signature) ............. :
Testing location / address ............. :
[]
Testing Procedure: SMT
Tested by (name + signature) ....... :
Approved by (+ signature) ............. :
Supervised by (+ signature) .......... :
Testing location / address ............. :
[]
Testing Procedure: RMT
Tested by (name + signature) ....... :
Approved by (+ signature) ............. :
Supervised by (+ signature) .......... :
Testing location / address ............. :
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 3 of 50
Report Reference #
ASL10120310
Summary of Testing:
No tests were conducted
Summary of Compliance with National Differences:
AT, AU, BE, BR, CA, CH, CZ, DE, DK, ES, EU, FI, FR, GB, GR, HU, IE, IT, JP, KR, NL, NO, PL, PT,
RO, SE, SG, SI, SK, UA, US
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 4 of 50
Report Reference #
Copy of Marking Plate
Notebook:
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 5 of 50
Report Reference #
Battery pack:
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 6 of 50
Report Reference #
ASL10120310
Test item particulars :
Equipment mobility ...............................................:
transportable
Connection to the mains ......................................:
No direct connection
Operating condition ..............................................:
continuous
Access location
:
Over voltage category (OVC) ...............................:
operator accessible
OVC I
Mains supply tolerance (%) or absolute mains supply Not directly connected to the mains
values ........................................................................:
Tested for IT power systems ...............................:
N/A
IT testing, phase-phase voltage (V) .....................:
N/A
Class of equipment ..............................................:
Class III (supplied by SELV)
Considered current rating (A) ..............................:
--
Pollution degree ...................................................:
PD 2
IP protection class ................................................:
IP X0
Altitude during operation (m) ....................................: Up to 2000m
Altitude of test laboratory (m) ....................................: Up to 2000m
Mass of equipment (kg) .......................................:
2.8 kg
Possible test case verdicts:
- test case does not apply to the test object ........:
N/A
- test object does meet the requirement ..............:
P(Pass)
- test object does not meet the requirement ........:
F(Fail)
Testing:
Date(s) of receipt of test item ...............................:
N/A
Date(s) of Performance of tests ...........................:
N/A
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
Refer to the Cover Page For Test Report for a list of all Factory Locations.
GENERAL PRODUCT INFORMATION:
Report Summary
All applicable tests according to the referenced standard(s) have been carried out.
Product Description
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 7 of 50
Report Reference #
ASL10120310
The equipment is Notebook PC for use in information technology equipment.
The equipment total overall see appended miscellaneous ID 7-02 for detail.
For motherboard type A15HC:
Electrical components are mounted on PWB which is enclosed by plastic Enclosure and accompanied with
one HDD, two USB3.0 ports, two USB2.0 ports, one VGA port, one RJ45 port, one HDMI port, two Audio
ports and one card reader.
Mother board type A15HC was provided two construction. Construction A without VGA-chip use power rating
19Vdc, 3.42A only; Construction B with VGA-chip use power rating 19Vdc, 4.74A only.
Model Differences
N/A
Additional Information
No tests were conducted due to this test report should be copy from
ASL10112909, issued 2010-12-28, with CB Certificate No. (DK-21362), issued 2010-12-29,
ASL10112909-001, issued 2011-01-07, with CB Certificate No. (DK-21362-A1), issued 2011-01-11 and
modify below items:
1. Add Trade Mark:
2. Replace Model name from A15xxxx to MS-16Y1, the new model MS-16Y1 is identical to A15xxxx except
for model designation.
3. Replace Manufacturer name from PEGATRON CORP/5TH FL, 76, LIGONG ST, BEITOU DISTRICT,
TAIPEI 112, TAIWAN to MICRO-STAR INTERNATIONAL CO., LTD / NO. 69, Li-De St, Jung He
city,Taipei Hsieh, Taiwan
The latest version of CB Bulletin on IECEE website has been taken into account and considered compliant.
The label is a draft of an artwork for marking plate pending approval by National Certification Bodies and it
shall not be affixed to products prior to such an approval.
Technical Considerations
The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by
the manufacturer’s specification of: 35 oC
The product was investigated to the following additional standards: EN 60950-1:2006+A11:2009 (which
includes all European national differences, including those specified in this test report).
The following circuit locations (with circuit/schematic designation) were investigated as a limited power
source (LPS): USB connectors, Speaker and HDMI connector. (Other connectors are classified as data ports
only.)
The following are available from the Applicant upon request: Installation (Safety) Instructions / Manual
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 8 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
1
GENERAL
Pass
1.5
Components
Pass
1.5.1
General
Pass
1.5.2
Result – Remark
Verdict
Comply with IEC 60950 or relevant component
standard
(see appended table 1.5.1)
Pass
Evaluation and testing of components
Certified components are
used in accordance with their
ratings, certifications and they
comply with applicable parts
of this standard.
Pass
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC
60950-1 and the relevant
component standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
1.5.3
Thermal controls
No thermal controls.
N/A
1.5.4
Transformers
No isolating transformer in the
equipment.
N/A
1.5.5
Interconnecting cables
Interconnecting cables comply
with the relevant requirements
of this standard.
Pass
1.5.6
Capacitors bridging insulation
Evaluated in power supply
approval.
N/A
1.5.7
Resistors bridging insulation
N/A
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
N/A
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
N/A
1.5.7.4
Accessible parts
N/A
1.5.8
Components in equipment for IT power systems
Class III equipment.
N/A
1.5.9
Surge suppressors
Class III equipment.
N/A
1.5.9.1
General
N/A
1.5.9.2
Protection of VDRs
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 9 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
1.5.9.3
Bridging of functional insulation by a VDR
N/A
1.5.9.4
Bridging of basic insulation by a VDR
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
N/A
1.6
Power interface
Pass
1.6.1
AC power distribution systems
Evaluated in power supply
approval.
N/A
1.6.2
Input current
(see appended table 1.6.2)
Pass
1.6.3
Voltage limit of hand-held equipment
N/A
1.6.4
Neutral conductor
N/A
1.7
Marking and instructions
Pass
1.7.1
Power rating
The required marking is
located on the outside surface
of the equipment.
Verdict
Pass
Rated voltage(s) or voltage range(s) (V) ............... : 19Vdc (Optional)
Pass
Symbol for nature of supply, for d.c. only .............. : IEC 60417 No. 5031 provided
on marking label. (Optional)
Pass
Rated frequency or rated frequency range (Hz).... : DC Source.
N/A
Rated current (mA or A) ........................................ : 3.42A or 4.74A (Optional)
Pass
Manufacturer's name or trademark or identification MICRO-STAR
mark....................................................................... : INTERNATIONAL CO., LTD or
Pass
Model identification or type reference ................... : MS-16Y1 / Notebook PC
Pass
Symbol for Class II equipment only....................... : The equipment is regarded as
Class III.
N/A
Other markings and symbols................................. : Additional symbols may be
provided when submitted for
National Approval.
Pass
1.7.2
Safety instructions and marking
Pass
1.7.2.1
General
1.7.2.2
Disconnect devices
Class III equipment.
N/A
1.7.2.3
Overcurrent protective device
No such device provided.
N/A
1.7.2.4
IT Power distribution systems
Class III equipment.
N/A
1.7.2.5
Operator access with a tool
TRF No. IECEN60950_1C
Safety instructions in English.
Other languages will be
provided when submitted for
national approval.
Pass
N/A
UL International Demko A/S
Issue Date:
2011-01-12
Page 10 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
1.7.2.6
Ozone
1.7.3
Short duty cycles
1.7.4
Supply voltage adjustment .................................... :
N/A
Method and means of adjustment; reference to
installation instructions .......................................... :
N/A
1.7.5
Power outlets on the equipment............................ : No standard power outlets are
provided.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) ........................... :
N/A
1.7.7
Wiring terminals
1.7.7.1
Protective earthing and bonding terminals ............ :
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
Pass
1.7.8.1
Identification, location and marking ....................... : The function of controls
affecting safety is obvious
regardless of language.
Pass
1.7.8.2
Colours .................................................................. : For functional indication a
LED lights when the
equipment is operating.
Pass
1.7.8.3
Symbols according to IEC 60417 .......................... : The stand-by switch is marked
with the correct symbol
(60417-1-IEC-5009).
Pass
1.7.8.4
Markings using figures........................................... :
N/A
1.7.9
Isolation of multiple power sources ....................... :
N/A
1.7.10
Thermostats and other regulating devices ............ :
N/A
1.7.11
Durability
All markings provided on UL
Recognized Component labels
suitable for surface they are
applied upon and meet the
durability test.
Pass
1.7.12
Removable parts
No marking is located on
removable parts.
Pass
1.7.13
Replaceable batteries............................................ :
N/A
Language(s) .......................................................... :
-
1.7.14
Equipment for restricted access locations............. :
N/A
2
PROTECTION FROM HAZARDS
Pass
2.1
Protection from electric shock and energy hazards
Pass
TRF No. IECEN60950_1C
Result – Remark
Verdict
N/A
Equipment is designed for
continuous operation.
Class III equipment, supplied
by SELV.
UL International Demko A/S
N/A
N/A
Issue Date:
2011-01-12
Page 11 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
2.1.1
Protection in operator access areas
See below.
Pass
2.1.1.1
Access to energized parts
The operator cannot access to
energized parts.
Pass
Test by inspection.................................................. : The operator has access to
bare parts of SELV circuits.
Pass
Test with test finger (Figure 2A) ............................ : The operator has access to
bare parts of SELV circuits.
N/A
Test with test pin (Figure 2B) ................................ : The operator has access to
bare parts of SELV circuits.
N/A
Test with test probe (Figure 2C)............................ : No TNV.
N/A
2.1.1.2
Battery compartments
N/A
2.1.1.3
Access to ELV wiring
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm) .......................... :
-
2.1.1.4
Access to hazardous voltage circuit wiring
No hazardous voltage present.
N/A
2.1.1.5
Energy hazards ..................................................... : Class III unit intended to be
supplied by an external
adaptor with no energy hazard.
Pass
2.1.1.6
Manual controls
The equipment does not
contain any knobs, handles,
levers, or the like.
N/A
2.1.1.7
Discharge of capacitors in equipment
Evaluated during separate
certification of the power
adapter.
N/A
Measured voltage (V); time-constant (s) ............... :
2.1.1.8
-
Energy hazards - d.c. mains supply
N/A
a) Capacitor connected to the d.c. mains supply .. :
N/A
b) Internal battery connected to the mains supply :
N/A
2.1.1.9
Audio amplifiers ..................................................... :
N/A
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
N/A
2.2
SELV circuits
Pass
2.2.1
General requirements
Class III unit intended to be
supplied by an external nonenergy hazardous SELV
power adapter.
Pass
2.2.2
Voltages under normal conditions (V) ................... : All accessible voltages are
less than 42.4 Vp or 60 Vdc
and are classified as SELV.
Pass
2.2.3
Voltages under fault conditions (V) ....................... : The unit is supplied by SELV
Pass
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 12 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
and all critical fault conditions
were considered in power
adaptor evaluation.
2.2.4
Connection of SELV circuits to other circuits ........ : SELV circuits are only
connected to other SELV
circuits.
Pass
2.3
TNV circuits
N/A
2.3.1
Limits
N/A
Type of TNV circuits .............................................. :
-
2.3.2
Separation from other circuits and from accessible
parts
N/A
2.3.2.1
General requirements
N/A
2.3.2.2
Protection by basic insulation
N/A
2.3.2.3
Protection by earthing
N/A
2.3.2.4
Protection by other constructions .......................... :
N/A
2.3.3
Separation from hazardous voltages
N/A
Insulation employed............................................... :
2.3.4
-
Connection of TNV circuits to other circuits
N/A
Insulation employed............................................... :
-
2.3.5
Test for operating voltages generated externally
N/A
2.4
Limited current circuits
N/A
2.4.1
General requirements
N/A
2.4.2
Limit values
N/A
Frequency (Hz)...................................................... :
-
Measured current (mA).......................................... :
-
Measured voltage (V) ............................................ :
-
Measured circuit capacitance (nF or uF)............... :
-
2.4.3
Connection of limited current circuits to other
circuits
N/A
2.5
Limited power sources
Pass
a) Inherently limited output
Connectors are determined
data pins only. See Enclosure
7-01 for detail.
Pass
b) Impedance limited output
USB outputs limited by PTC
devices.
Pass
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 13 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
See Table 1.5.1 for PTC
specifications.
c) Regulating network limited output under normal
operating and single fault condition
N/A
d) Overcurrent protective device limited output
N/A
Max. output voltage (V), max. output current (A),
See Enclosure 7-01 for detail.
max. apparent power (VA) .................................... :
-
Current rating of overcurrent protective device (A) :
-
2.6
Provisions for earthing and bonding
Pass
2.6.1
Protective earthing
2.6.2
Functional earthing
N/A
2.6.3
Protective earthing and protective bonding
conductors
N/A
2.6.3.1
General
N/A
2.6.3.2
Size of protective earthing conductors
N/A
Class III equipment.
Rated current (A), cross-sectional area (mm2),
AWG ...................................................................... :
2.6.3.3
Size of protective bonding conductors
N/A
N/A
Rated current (A), cross-sectional area mm2),
AWG ...................................................................... :
-
2.6.3.4
Resistance of earthing conductors and their
terminations; resistance (ohm), voltage drop (V),
test current (A), duration (min) .............................. :
N/A
2.6.3.5
Colour of insulation................................................ :
N/A
2.6.4
Terminals
N/A
2.6.4.1
General
N/A
2.6.4.2
Protective earthing and bonding terminals
N/A
Rated current (A), type, nominal thread diameter
(mm) ...................................................................... :
-
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
N/A
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
N/A
2.6.5.5
Parts removed during servicing
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 14 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
Screws for protective bonding
N/A
2.6.5.8
Reliance on telecommunication network or cable
distribution system
N/A
2.7
Overcurrent and earth fault protection in primary circuits
N/A
2.7.1
Basic requirements
N/A
Class III equipment.
Verdict
Instructions when protection relies on building
installation
N/A
2.7.2
Faults not covered in 5.3.7
N/A
2.7.3
Short-circuit backup protection
N/A
2.7.4
Number and location of protective devices ........... :
N/A
2.7.5
Protection by several devices
N/A
2.7.6
Warning to service personnel................................ :
N/A
2.8
Safety interlocks
N/A
2.8.1
General principles
N/A
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches and relays
N/A
2.8.7.1
Contact gaps (mm) ................................................ :
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8
Mechanical actuators
N/A
2.9
Electrical insulation
Pass
2.9.1
Properties of insulating materials
2.9.2
Humidity conditioning
Natural rubber, materials
containing asbestos and
hygroscopic materials are not
used as insulation.
N/A
Relative humidity (%), temperature (¢XC)............. :
2.9.3
Grade of insulation
TRF No. IECEN60950_1C
Pass
Functional insulation.
UL International Demko A/S
Pass
Issue Date:
2011-01-12
Page 15 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
Insulation in power supply is
evaluated in power supply
approval.
2.9.4
Separation from hazardous voltages
Evaluated in power supply
approval.
Method(s) used...................................................... :
N/A
-
2.10
Clearances, creepage distances and distances through insulation
Pass
2.10.1
General
Pass
Insulation are considered
evaluated in power supply
approval.
For functional insulation see
5.3.4.
Pollution degree 2 applicable.
2.10.1.1
Frequency.............................................................. : Evaluated during separate
certification of the power
adapter.
Pass
2.10.1.2
Pollution degrees................................................... : Pollution Degree 2.
Pass
2.10.1.3
Reduced values for functional insulation
Pass
2.10.1.4
Intervening unconnected conductive parts
N/A
2.10.1.5
Insulation with varying dimensions
N/A
2.10.1.6
Special separation requirements
N/A
2.10.1.7
Insulation in circuits generating starting pulses
N/A
2.10.2
Determination of working voltage
2.10.2.1
General
N/A
2.10.2.2
RMS working voltage
N/A
2.10.2.3
Peak working voltage
N/A
2.10.3
Clearances
2.10.3.1
General
N/A
2.10.3.2
Mains transient voltages
N/A
a) AC mains supply ............................................... :
N/A
b) Earthed d.c. mains supplies .............................. :
N/A
c) Unearthed d.c.. mains supplies ......................... :
N/A
d) Battery operation ............................................... :
N/A
Clearances in primary circuits
N/A
2.10.3.3
TRF No. IECEN60950_1C
Evaluated during separate
certification of the power
adapter.
See appended table 2.10.3
and 2.10.4 and clause 5.3.4.
UL International Demko A/S
N/A
Pass
Issue Date:
2011-01-12
Page 16 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
2.10.3.4
Clearances in secondary circuits
N/A
2.10.3.5
Clearances in circuits having starting pulses
N/A
2.10.3.6
Transients from a.c. mains supply......................... :
N/A
2.10.3.7
Transients from d.c. mains supply......................... :
N/A
2.10.3.8
Transients from telecommunication networks and
cable distribution systems ..................................... :
N/A
2.10.3.9
Measurement of transient voltage levels
N/A
a) Transients from a mains supply
N/A
For an a.c. mains supply ....................................... :
N/A
For a d.c. mains supply ......................................... :
N/A
b) Transients from a telecommunication network
N/A
See appended table 2.10.3
and 2.10.4 and clause 5.3.4.
Verdict
2.10.4
Creepage distances
2.10.4.1
General
N/A
2.10.4.2
Material group and comparative tracking index
N/A
CTI tests ................................................................ : Material group IIIb assumed;
CTI < 175.
Pass
-
2.10.4.3
Minimum creepage distances
N/A
2.10.5
Solid insulation
N/A
2.10.5.1
General
N/A
2.10.5.2
Distances through insulation
N/A
2.10.5.3
Insulating compound as solid insulation
N/A
2.10.5.4
Semiconductor devices
N/A
2.10.5.5
Cemented joints
N/A
2.10.5.6
Thin sheet material - General
N/A
2.10.5.7
Separable thin sheet material
N/A
Number of layers (pcs) .......................................... :
-
2.10.5.8
Non-separable thin sheet material
N/A
2.10.5.9
Thin sheet material - standard test procedure
N/A
Electric strength test .............................................. :
2.10.5.10
Thin sheet material - alternative test procedure
Electric strength test .............................................. :
N/A
-
2.10.5.11
Insulation in wound components
N/A
2.10.5.12
Wire in wound components
N/A
Working voltage..................................................... :
N/A
a) Basic insulation not under stress ...................... :
N/A
b) Basic, supplementary, reinforced insulation ..... :
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 17 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
2.10.5.13
Requirement - Test
Result – Remark
c) Compliance with Annex U ................................. :
N/A
Two wires in contact inside wound component;
angle between 45 oC and 90 oC ............................. :
N/A
Wire with solvent-based enamel in wound
components
N/A
Electric strength test .............................................. :
-
Routine test
2.10.5.14
Verdict
N/A
Additional insulation in wound components
Evaluated in power supply
approval.
N/A
Working voltage..................................................... :
N/A
- Basic insulation not under stress ........................ :
N/A
- Supplementary, reinforced insulation.................. :
N/A
2.10.6
Construction of printed boards
N/A
2.10.6.1
Uncoated printed boards
N/A
2.10.6.2
Coated printed boards
2.10.6.3
Insulation between conductors on the same inner
surface of a printed board
N/A
2.10.6.4
Insulation between conductors on different layers
of a printed board
N/A
Distance through insulation
N/A
Number of insulation layers (pcs).......................... :
N/A
2.10.7
Component external terminations
N/A
2.10.8
Tests on coated printed boards and coated
components
N/A
2.10.8.1
Sample preparation and preliminary inspection
2.10.8.2
Thermal conditioning
N/A
2.10.8.3
Electric strength test
N/A
2.10.8.4
Abrasion resistance test
N/A
2.10.9
Thermal cycling
N/A
2.10.10
Test for Pollution Degree 1 environment and
insulating compound
N/A
2.10.11
Tests for semiconductor devices and cemented
joints
N/A
2.10.12
Enclosed and sealed parts
N/A
3
WIRING, CONNECTIONS AND SUPPLY
Pass
3.1
General
Pass
TRF No. IECEN60950_1C
No coated printed boards.
No special coating in order
reduce distances.
UL International Demko A/S
N/A
N/A
Issue Date:
2011-01-12
Page 18 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
3.1.1
Current rating and overcurrent protection
Adequate cross sectional
areas on internal wiring.
Pass
3.1.2
Protection against mechanical damage
Wire ways are smooth and
free from edges. Wires are
adequately fixed to prevent
excessive strain on wire and
terminals and avoiding
damage to the insulation of the
conductor..
Pass
3.1.3
Securing of internal wiring
Internal wiring is secured
against excessive strain,
loosening of terminals and
damage to the conductor
insulation.
Pass
3.1.4
Insulation of conductors
Insulation on internal
conductors is considered to be
of adequate quality and
suitable for the application and
the working voltage involved.
Pass
3.1.5
Beads and ceramic insulators
No beads or similar ceramic
insulators on conductors.
N/A
3.1.6
Screws for electrical contact pressure
No electrical contact pressure.
N/A
3.1.7
Insulating materials in electrical connections
No contact pressure through
insulating material
N/A
3.1.8
Self-tapping and spaced thread screws
Thread-cutting or space thread
screws are not used for
electrical connections.
Pass
3.1.9
Termination of conductors
Terminations cannot become
displaced so that clearances and
creepage distance can be
reduced.
Pass
10 N pull test
All conductors are reliably
secured.
Pass
3.1.10
Sleeving on wiring
No sleeving used as
supplementary insulation.
3.2
Connection to mains supply
3.2.1
Means of connection
3.2.1.1
Connection to an a.c. mains supply
N/A
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
3.2.3
Permanently connected equipment
N/A
N/A
N/A
No direct connection to mains.
Number of conductors, diameter of cable and
TRF No. IECEN60950_1C
Verdict
UL International Demko A/S
N/A
-
Issue Date:
2011-01-12
Page 19 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
conduits (mm)........................................................ :
3.2.4
Appliance inlets
N/A
3.2.5
Power supply cords
N/A
3.2.5.1
AC power supply cords
N/A
Type....................................................................... :
-
Rated current (A), cross-sectional area (mm2),
AWG ...................................................................... :
-
3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
N/A
Mass of equipment (kg), pull (N) ........................... :
-
Longitudinal displacement (mm) ........................... :
-
3.2.7
Protection against mechanical damage
N/A
3.2.8
Cord guards
N/A
Diameter of minor dimension D (mm); test mass (g)
............................................................................... :
-
Radius of curvature of cord (mm).......................... :
-
3.2.9
Supply wiring space
N/A
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
Rated current (A), cord/cable type, cross-sectional
area (mm2) ............................................................ :
3.3.5
-
Wiring terminal sizes
N/A
Rated current (A), type and nominal thread
diameter (mm) ....................................................... :
-
3.3.6
Wiring terminals design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8
Stranded wire
N/A
3.4
Disconnection from the mains supply
N/A
3.4.1
General requirement
3.4.2
Disconnect devices
N/A
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
TRF No. IECEN60950_1C
No direct connection to mains.
UL International Demko A/S
N/A
Issue Date:
2011-01-12
Page 20 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles - single-phase and d.c. equipment
N/A
3.4.7
Number of poles - three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
Pass
3.5.1
General requirements
3.5.2
Types of interconnection circuits ........................... : Interconnection circuits are
SELV, Limited Current Circuit,
TNV-3 circuits.
Pass
3.5.3
ELV circuits as interconnection circuits
No ELV interconnections.
N/A
3.5.4
Data ports for additional equipment
Data parts only signal.
Pass
4
PHYSICAL REQUIREMENTS
Pass
4.1
Stability
N/A
Angle of 10°
N/A
Test force (N)......................................................... : The unit is not floor-standing
equipment.
N/A
4.2
Mechanical strength
Pass
4.2.1
General
4.2.2
Steady force test, 10 N
N/A
4.2.3
Steady force test, 30 N
N/A
4.2.4
Steady force test, 250 N
4.2.5
Impact test
N/A
Fall test
N/A
Swing test
N/A
Drop test; height (mm)........................................... : - Transportable equipment.
No damage after 1m drop.
- There was no possible of
Pass
4.2.6
TRF No. IECEN60950_1C
Result – Remark
Interconnection circuit selected
to provided conformance to the
requirements of 2.2 for SELV
CIRCUITS.
Complies with the requirement
also after tests described
below are applied.
No hazards as a result of the
250N test.
UL International Demko A/S
Verdict
Pass
Pass
Pass
Issue Date:
2011-01-12
Page 21 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
accessing hazardous parts.
4.2.7
Stress relief test
Test is carried out at 70 oC/ 7h,
No risk of shrinkage or
distortion on enclosures due to
release of internal stresses.
Pass
4.2.8
Cathode ray tubes
No such device within the
equipment.
N/A
Picture tube separately certified ............................ :
N/A
4.2.9
High pressure lamps
No high pressure lamp.
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ....... :
N/A
4.3
Design and construction
Pass
4.3.1
Edges and corners
All edges and corners are
judged to be sufficiently well
rounded so as not to constitute
a hazard.
Pass
4.3.2
Handles and manual controls; force (N)................ : None that would cause hazard
N/A
4.3.3
Adjustable controls
No such device within the
equipment
N/A
4.3.4
Securing of parts
Mechanical connections can
be expected to withstand usual
mechanical stress.
Pass
4.3.5
Connection by plugs and sockets
4.3.6
Direct plug-in equipment
N/A
Not a direct plug-in unit.
N/A
Torque ................................................................... :
N/A
Compliance with the relevant mains plug standard:
N/A
4.3.7
Heating elements in earthed equipment
No such device within the
equipment
N/A
4.3.8
Batteries
Battery Pack are nonapproved component, there is
no reverse polarity installation
could be happen due to design
of socket and mechanical
construction in Notebook PC.
Pass
- The RTC battery protected by
D2001 and R2001 for M/B:
A15HC.
(see appended table 5.3)
- Overcharging of a rechargeable battery
N/A
- Unintentional charging of a non-rechargeable
battery
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 22 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
- Reverse charging of a rechargeable battery
N/A
- Excessive discharging of any battery
N/A
4.3.9
Oil and grease
N/A
4.3.10
Dust, powders, liquids and gases
N/A
4.3.11
Containers for liquids or gases
N/A
4.3.12
Flammable liquids.................................................. :
N/A
Quantity of liquid (l)................................................ :
N/A
Flash point (C)...................................................... :
N/A
4.3.13
Radiation
N/A
4.3.13.1
General
N/A
4.3.13.2
Ionizing radiation
N/A
4.3.13.3
Measured radiation (pA/kg) ................................... :
-
Measured high-voltage (kV) .................................. :
-
Measured focus voltage (kV)................................. :
-
CRT markings........................................................ :
-
Effect of ultraviolet (UV) radiation on materials
N/A
Part, property, retention after test, flammability
classification .......................................................... :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation ....... :
N/A
4.3.13.5
Laser (including LEDs)
This product contains only
visible indicator LEDs (Class
1) operating in the range of
400 - 700 nm wavelength. No
IEC60825-1 evaluation was
deemed necessary. Additional
review may be required at the
discretion of the accepting
NCB.
Laser class ............................................................ : This product contains only
visible indicator LEDs (Class
1) operating in the range of
400 - 700 nm wavelength. No
IEC60825-1 evaluation was
deemed necessary. Additional
review may be required at the
discretion of the accepting
NCB.
Pass
-
4.3.13.6
Other types ............................................................ :
N/A
4.4
Protection against hazardous moving parts
Pass
4.4.1
General
TRF No. IECEN60950_1C
Resetting of internal
UL International Demko A/S
Pass
Issue Date:
2011-01-12
Page 23 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
components during operation
does not present a risk of
personal injury.
4.4.2
Protection in operator access areas...................... : No hazardous moving parts in
operator access areas..
N/A
4.4.3
Protection in restricted access locations ............... :
N/A
4.4.4
Protection in service access areas
4.5
Thermal requirements
Pass
4.5.1
General
Pass
4.5.2
Temperature tests
Unintentional contact with
hazardous moving parts by
service personnel is unlikely.
The equipment and its
components did not attain
excessive temperature during
normal operation.
(See appended table 4.5)
Normal load condition per Annex L ....................... : Operated in the most
unfavorable way of operation
given in the operating
instructions until steady
conditions established.
Pass
Pass
-
4.5.3
Temperature limits for materials
(See appended table 4.5)
Pass
4.5.4
Touch temperature limits
(See appended table 4.5)
Pass
4.5.5
Resistance to abnormal heat................................. : Evaluated during separate
certification of the power
adapter.
N/A
4.6
Openings in enclosures
Pass
4.6.1
Top and side openings
Transportable equipment.
Dimensions (mm) .................................................. :
4.6.2
Bottoms of fire enclosures
N/A
-
Transportable equipment.
Construction of the bottom, dimensions (mm) ...... :
N/A
-
4.6.3
Doors or covers in fire enclosures
4.6.4
Openings in transportable equipment
Fire enclosure construction is
considered to comply with the
requirement.
See appended miscellaneous
of ID 7-03
Pass
4.6.4.1
Constructional design measures
Openings do not exceed 1 mm
in width regardless of length.
(fan openings are achieved via
Pass
TRF No. IECEN60950_1C
N/A
UL International Demko A/S
Issue Date:
2011-01-12
Page 24 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
internal heatsink construction)
Dimensions (mm) .................................................. : Fire enclosure construction is
considered to comply with the
requirement.
See appended miscellaneous
of ID 7-03
-
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
N/A
-
Conditioning temperature (C), time (weeks) ........ :
4.7
Resistance to fire
Pass
4.7.1
Reducing the risk of ignition and spread of flame
Method 1 - Selection and
application of components,
wiring and materials, which
reduce the possibility of
ignition and spread of flame by
the use of fire enclosure.
Pass
Method 1, selection and application of components
wiring and materials
Pass
Method 2, application of all of simulated fault
condition tests
N/A
4.7.2
Conditions for a fire enclosure
See 4.7.2.1.
Pass
4.7.2.1
Parts requiring a fire enclosure
Fire enclosure covers all parts.
Pass
4.7.2.2
Parts not requiring a fire enclosure
N/A
4.7.3
Materials
Pass
4.7.3.1
General
Components and materials
have adequate flammability
classification. See appended
table 1.5.1
Pass
4.7.3.2
Materials for fire enclosures
(See appended table 1.5.1)
Pass
4.7.3.3
Materials for components and other parts outside
fire enclosures
Decorative parts and parts
outside of the fire enclosure
are made of minimum HB
material.
Pass
Connectors are made of
materials of Class V-2
minimum.
4.7.3.4
Materials for components and other parts inside fire Other materials inside fire
enclosures
enclosure are minimum V-2
material
Pass
4.7.3.5
Materials for air filter assemblies
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 25 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
4.7.3.6
Materials used in high-voltage components
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
Pass
5.1
Touch current and protective conductor current
N/A
5.1.1
General
5.1.2
Configuration of equipment under test (EUT)
N/A
5.1.2.1
Single connection to an a.c. mains supply
N/A
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c. mains
supply
N/A
5.1.3
Test circuit
N/A
5.1.4
Application of measuring instrument
N/A
5.1.5
Test procedure
N/A
5.1.6
Test measurements
N/A
Evaluated as part of power
supply investigation.
Verdict
N/A
Supply voltage (V) ................................................. :
-
Measured touch current (mA)................................ :
-
Max. allowed touch current (mA)........................... :
-
Measured protective conductor current (mA)........ :
-
Max. allowed protective conductor current (mA)... :
-
5.1.7
Equipment with touch current exceeding 3,5 mA
N/A
5.1.7.1
General.................................................................. :
N/A
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and No TNV presents.
cable distribution systems and from
telecommunication networks
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
N/A
5.1.8.2
Supply voltage (V) ................................................. :
-
Measured touch current (mA)................................ :
-
Max. allowed touch current (mA)........................... :
-
Summation of touch currents from
telecommunication networks
N/A
a) EUT with earthed telecommunication ports ...... :
N/A
b) EUT whose telecommunication ports have no
reference to protective earth
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 26 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
5.2
Electric strength
N/A
5.2.1
General
N/A
5.2.2
Test procedure
N/A
5.3
Abnormal operating and fault conditions
Pass
5.3.1
Protection against overload and abnormal
operation
(See appended table 5.3)
Pass
5.3.2
Motors
Approval DC Fan used.
N/A
5.3.3
Transformers
No isolating transformer in the
equipment.
N/A
5.3.4
Functional insulation.............................................. : Functional insulation complies
with requirement (c).
Pass
Considered due to all
components are mounted on
PCB of flammability V-1 min
5.3.5
Electromechanical components
N/A
5.3.6
Audio amplifiers in ITE........................................... :
N/A
5.3.7
Simulation of faults
5.3.8
Unattended equipment
5.3.9
Compliance criteria for abnormal operating and
fault conditions
No fire occurred. No molten
metal was emitted.
Pass
5.3.9.1
During the tests
No fire, emission of molten
metal or deformation was
noted during the tests.
Pass
5.3.9.2
After the tests
N/A
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
N/A
(See appended table 5.3)
Pass
N/A
Supply voltage (V) ................................................. :
-
Current in the test circuit (mA)............................... :
-
6.1.2.2
Exclusions ............................................................. :
N/A
6.2
Protection of equipment users from overvoltages on telecommunication
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 27 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
networks
6.2.1
Separation requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1
Impulse test
N/A
6.2.2.2
Steady-state test
N/A
6.2.2.3
Compliance criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A).......................................... :
-
Current limiting method ......................................... :
-
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
General
N/A
7.2
Protection of cable distribution system service persons, and users of other
equipment connected to the system, from hazardous voltages in the equipment
N/A
7.3
Protection of equipment users from overvoltages
on the cable distribution system
N/A
7.4
Insulation between primary circuits and cable
distribution systems
N/A
7.4.1
General
N/A
7.4.2
Voltage surge test
N/A
7.4.3
Impulse test
N/A
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
A.1
Flammability test for fire enclosures of movable equipment having a total mass
exceeding 18 kg, and of stationary equipment (see 4.7.3.2)
N/A
A.1.1
Samples................................................................. :
-
Wall thickness (mm) .............................................. :
-
o
A.1.2
Conditioning of samples; temperature ( C) ........... :
N/A
A.1.3
Mounting of samples ............................................. :
N/A
A.1.4
Test flame (see IEC 60695-11-3)
N/A
Flame A, B, C or D ................................................ :
N/A
A.1.5
Test procedure
N/A
A.1.6
Compliance criteria
N/A
Sample 1 burning time (s) ..................................... :
-
Sample 2 burning time (s) ..................................... :
-
Sample 3 burning time (s) ..................................... :
-
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 28 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
A.2
Flammability test for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
A.2.1
Samples, material.................................................. :
-
Wall thickness (mm) .............................................. :
-
A.2.2
Conditioning of samples; temperature (C) ........... :
N/A
A.2.3
Mounting of samples ............................................. :
N/A
A.2.4
Test flame (see IEC 60695-11-4)
N/A
Flame A, B or C ..................................................... :
Verdict
N/A
-
A.2.5
Test procedure
N/A
A.2.6
Compliance criteria
N/A
A.2.7
Sample 1 burning time (s) ..................................... :
-
Sample 2 burning time (s) ..................................... :
-
Sample 3 burning time (s) ..................................... :
-
Alternative test acc. to IEC 60695-11-5, cl. 5 and 9
N/A
Sample 1 burning time (s) ..................................... :
-
Sample 2 burning time (s) ..................................... :
-
Sample 3 burning time (s) ..................................... :
-
A.3
Hot flaming oil test (see 4.6.2)
N/A
A.3.1
Mounting of samples
N/A
A.3.2
Test procedure
N/A
A.3.3
Compliance criterion
N/A
B
ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS(see 4.7.2.2 and
5.3.2)
N/A
B.1
General requirements
N/A
Position.................................................................. :
-
Manufacturer ......................................................... :
-
Type....................................................................... :
-
Rated values.......................................................... :
-
B.2
Test conditions
N/A
B.3
Maximum temperatures
N/A
B.4
Running overload test
N/A
B.5
Locked-rotor overload test
N/A
B.6
Test duration (days)............................................... :
-
Electric strength test: test voltage (V).................... :
-
Running overload test for d.c. motors in secondary
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 29 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
circuits
B.6.1
General
N/A
B.6.2
Test procedure
N/A
B.6.3
Alternative test procedure
N/A
B.6.4
Electric strength test; test voltage (V).................... :
N/A
B.7
Locked-rotor overload test for d.c. motors in secondary circuits
N/A
B.7.1
General
N/A
B.7.2
Test procedure
B.7.3
Alternative test procedure
N/A
B.7.4
Electric strength test; test voltage (V).................... :
N/A
B.8
Test for motors with capacitors
N/A
B.9
Test for three-phase motors
N/A
B.10
Test for series motors
N/A
.
Operating voltage (V) ............................................ :
C
ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3)
N/A
N/A
Position.................................................................. :
-
Manufacturer ......................................................... :
-
Type....................................................................... :
-
Rated values.......................................................... :
-
Method of protection.............................................. :
-
C.1
Overload test
N/A
C.2
Insulation
N/A
Protection from displacement of windings............. :
N/A
D
ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS (see
5.1.4)
N/A
D.1
Measuring instrument
N/A
D.2
Alternative measuring instrument
N/A
E
ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13)
N/A
F
ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10 and Annex G)
Pass
G
ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 30 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
G.1
Clearances
N/A
G.1.1
General
N/A
G.1.2
Summary of the procedure for determining
minimum clearances
N/A
G.2
Determination of mains transient voltage (V)
N/A
G.2.1
AC mains supply.................................................... :
N/A
G.2.2
Earthed d.c. mains supply ..................................... :
N/A
G.2.3
Unearthed d.c. mains supply................................. :
N/A
G.2.4
Battery operation ................................................... :
N/A
G.3
Determination of telecommunication network
transient voltage (V) : ............................................ :
N/A
G.4
Determination of required withstand voltage (V)
N/A
G.4.1
Mains transients and internal repetitive peaks ...... :
N/A
G.4.2
Transients from telecommunication networks....... :
N/A
G.4.3
Combination of transients
N/A
G.4.4
Transients from cable distribution systems
N/A
G.5
Measurement of transient voltages (V)
N/A
G.6
Determination of minimum clearances .................. :
N/A
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N/A
J
ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
N/A
Metal(s) used......................................................... :
Verdict
-
K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8)
N/A
K.1
Making and breaking capacity
N/A
K.2
Thermostat reliability; operating voltage (V).......... :
N/A
K.3
Thermostat endurance test; operating voltage (V) :
N/A
K.4
Temperature limiter endurance; operating voltage
(V) .......................................................................... :
N/A
K.5
Thermal cut-out reliability
N/A
K.6
Stability of operation
N/A
L
ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)
Pass
L.1
Typewriters
N/A
L.2
Adding machines and cash registers
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 31 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
L.3
Erasers
N/A
L.4
Pencil sharpeners
N/A
L.5
Duplicators and copy machines
N/A
L.6
Motor-operated files
N/A
L.7
Other business equipment
M
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N/A
M.1
Introduction
N/A
M.2
Method A
N/A
M.3
Method B
N/A
M.3.1
Ringing signal
N/A
M.3.1.1
Frequency (Hz)...................................................... :
-
M.3.1.2
Voltage (V)............................................................. :
-
M.3.1.3
Cadence; time (s), voltage (V)............................... :
-
M.3.1.4
Single fault current (mA)........................................ :
-
M.3.2
Tripping device and monitoring voltage................. :
N/A
M.3.2.1
Conditions for use of a tripping device or a
monitoring voltage
N/A
M.3.2.2
Tripping device
N/A
M.3.2.3
Monitoring voltage (V) ........................................... :
N/A
N
ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1,
7.3.2, 7.4.3 and Clause G.5)
N/A
N.1
ITU-T impulse test generators
N/A
N.2
IEC 60065 impulse test generator
N/A
P
ANNEX P, NORMATIVE REFERENCES
Pass
Q
ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1)
N/A
a) Preferred climatic categories............................. :
N/A
b) Maximum continuous voltage............................ :
N/A
c) Pulse current ..................................................... :
N/A
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
N/A
R
TRF No. IECEN60950_1C
Result – Remark
See table 1.6.2
UL International Demko A/S
Verdict
Pass
Issue Date:
2011-01-12
Page 32 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
Result – Remark
Verdict
PROGRAMMES
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6.2)
N/A
R.2
Reduced clearances (see 2.10.3)
N/A
S
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N/A
S.1
Test equipment
N/A
S.2
Test procedure
N/A
S.3
Examples of waveforms during impulse testing
N/A
T
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see
1.1.2)
N/A
............................................................................... :
U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
............................................................................... :
-
N/A
-
V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
N/A
V.1
Introduction
N/A
V.2
TN power distribution systems
N/A
W
ANNEX W, SUMMATION OF TOUCH CURRENTS
N/A
W.1
Touch current from electronic circuits
N/A
W.1.1
Floating circuits
N/A
W.1.2
Earthed circuits
N/A
W.2
Interconnection of several equipments
N/A
W.2.1
Isolation
N/A
W.2.2
Common return, isolated from earth
N/A
W.2.3
Common return, connected to protective earth
N/A
X
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see
clause C.1)
N/A
X.1
Determination of maximum input current
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 33 of 50
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement - Test
X.2
Overload test procedure
N/A
Y
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)
N/A
Y.1
Test apparatus....................................................... :
N/A
Y.2
Mounting of test samples ...................................... :
N/A
Y.3
Carbon-arc light-exposure apparatus.................... :
N/A
Y.4
Xenon-arc light-exposure apparatus ..................... :
N/A
Z
ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)
N/A
AA
ANNEX AA, MANDREL TEST (see 2.10.5.8)
N/A
TRF No. IECEN60950_1C
Result – Remark
UL International Demko A/S
Verdict
Issue Date:
1.5.1
2011-01-12
Page 34 of 50
Report Reference #
ASL10120310
Pass
TABLE: list of critical components
object/part No.
manufacturer/
trademark
Enclosure (LCD Sabic Innovative
top cover)
Plastics Japan
LLC
Enclosure ( for
Sabic Innovative
LCD front bezel) Plastics Japan
LLC
Enclosure ( for
Sabic Innovative
top side
Plastics Japan
keyboard
LLC
around)
Enclosure ( for
Sabic Innovative
top side
Plastics Japan
keyboard
LLC
around)
LCD Panel
Various
Power Adapter
Delta Electronics
Inc. /(trademark
for ASUS)
Delta Electronics
Inc. /(trademark
for ASUS)
Lite-On
Technology
Corp.
/(trademark for
ASUS)
FSP Group Inc.
Delta Electronics
Inc/ (trademark
for ASUS)
Delta Electronics
Inc/ (trademark
for ASUS)
Delta Electronics
Inc
TRF No. IECEN60950_1C
type/model
technical data
V-0, thickness
1.2 mm min. 85
o
C
CM6140(X)
V-1, thickness
0.6 mm min. 60
o
C
C6600(GG)(X)(V V-1, thickness
S)
1.2 mm min. 60
o
C
UL 94
mark(s) of
conformity1)
UL
UL 94
UL
UL 94
UL
C6600(GG)(X)(V V-1, thickness
S)
1.2 mm min. 60
o
C
UL 94
UL
Various
--
C7230P(X)
15.6 inch (LED
Backlight)
ADP-90CD DB
I/P:100-240Vac,
50-60Hz, 1.5A
O/P: 19Vdc,
4.74A (Class I)
40°C
ADP-90CD CB
I/P:100-240Vac,
50-60Hz, 1.5A
O/P: 19Vdc,
4.74A (Class II)
40°C
PA-1900-36..
I/P:100-240Vac,
(The dots “.” in
50-60Hz, 1.5A
model name
O/P: 19Vdc,
may be 0-9, A-Z, 4.74A (Class I)
“-“ or blank for
40°C
marketing
purpose only.)
FSP090I/P:100-240Vac,
DVCA1XX (X=
50-60Hz, 1.5A
0-9, A-Z or blank O/P: 19Vdc,
for marketing
4.74A (Class II)
purpose only)
40°C
ADP-65JH BB
I/P:100-240Vac,
1.5A, 50-60Hz;
O/P:19Vdc,
3.42A, (Class I),
(LPS), 40°C
ADP-65JH AB
I/P:100-240Vac,
1.5A, 50-60Hz;
O/P:19Vdc,
3.42A, (Class II),
(LPS), 40°C
ADP-65JH CB
I/P:100-240Vac,
1.5A, 50-60Hz;
O/P:19Vdc,
UL International Demko A/S
standard
Tested in the
equip.
UL 60950-1 2nd , UL, CB by
IEC 60950-1:
TUV/Rh
2005
(Certificate no.
EN 60950JPTUV-028022)
1:2006
UL 60950-1 2nd , CB by TUV/RH
IEC 60950-1:
(Certificate no.
2005
JPTUV-027230)
EN 609501:2006
UL 60950-1 2nd , UL, CB by
IEC 60950-1:
Nemko
2005
(Certificate no.
EN 60950NO51279)
1:2006
IEC 60950-1:
2005+A1
CB by TUV/RH
(Certificate no.
JPTUV-035798)
UL 60950-1 2nd ,
IEC 60950-1:
2005
EN 609501:2006
UL 60950-1 2nd ,
IEC 60950-1:
2005
EN 609501:2006
UL 60950-1 2nd ,
IEC 60950-1:
2005
UL, CB by
TUV/Rh
(Certificate no.
JPTUV-028160M1)
UL, CB by
TUV/Rh
(Certificate no.
JPTUV-028167)
UL, CB by
TUV/Rh
(Certificate no.
Issue Date:
2011-01-12
Lite-On
Technology
Corp.
/(trademark for
ASUS)
FSP Group Inc.
HDD (optional)
Seagate
Technology, Inc
(or equivalent)
Optical Drive
Hitachi-LG Data
Device (optional) Storage, Inc
(or equivalent)
Page 35 of 50
3.42A, (Class II),
(LPS), 40°C
PA-1650-66XX
I/P: 100-240Vac,
(The X can be A- 50-60Hz, 2.0A
Z, 0-9, hyphen or O/P: 19Vdc,
blank)
3.42A (Class I),
(LPS), 40°C
FSP065-ASCXX I/P: 100-240Vac,
50-60Hz, 2.0A
(the suffix “XX”
may be 0-9, A-Z O/P: 19Vdc,
3.42A (Class II),
or blank)
(LPS), 35°C
ST9
5Vdc, 1.5A max.
(or equivalent)
Speaker
(Two provided)
Various
GCC4244N*******
(where “*” can
be any
alphanumeric
character,
symbol, blank
indicating
different
marketing area
or band name)
(or equivalent)
Various
Accessory,
Rechargeable
Li-ion Battery
(3S2P)
-Battery Cell
(3S2P)
Pegatron Corp.
A32-A15
- Top/Bottom
Enclosure for
battery pack
-Glue (for
Top/Bottom
Enclosure)
-Fuse (F1)
-Thermistor
Samsung SDI
Co Ltd
ICR18650-22++
(++=These cells
may have an
optional single
alphanumeric
suffix.)
Sabic Innovative BPL1000(C)
Plastics Japan L
LC
LN-2250
Taiwan
Cemedine co.,
Ltd.
Sony Chemicals SFH-1212#
Corp.
(# represents
suffix of
alphabetical
letter used for
internal
traceability)
Various
Various
TRF No. IECEN60950_1C
Report Reference #
EN 609501:2006
IEC 60950-1:
2005
EN 609501:2006+A11:200
9
IEC 60950-1:
2005
EN 609501:2006+A11:200
9
UL/EN/IEC
60950-1
5Vdc, 2.8A max. UL/EN/IEC
Laser Class 1
60950-1, EN
product
/IEC 60825-1
ASL10120310
JPTUV-028159M2)
CB by TUV/RH
(Certificate no.
JPTUV-031574)
CB by VDE
(Certificate no.
DE1-47252)
UL, TUV, VDE,
Nemko
UL, TUV, VDE,
Nemko
Minimum HB,
Each rated, 4
ohm, 2.5 Watts
max.
10.8 Vdc, 4400
mAh or 47 Wh
--
Tested in the
equip.
--
Tested in the
equip.
3.6Vdc,
2200mAh
(lithium type )
UL1642
UL
V-1 or better,
min thick 0.7
mm, 80 oC
Max. Temp
Rating 60 oC.
UL94, UL 746C
UL
UL 746C
UL
12A, 36Vdc
UL 248-1,
UL 248-14,
EN 60127-1,
EN 60127-3
UL, TUV/Rh
(Certificate no.:
J 9650637)
10K ohm 25 oC
--
Tested in the
UL International Demko A/S
Issue Date:
2011-01-12
(TH1)
-Mosfet (Q1, Q2) Infineon
Technologies
-Protection IC
Texas
(U1)
Instruments
-PCB
Various
Accessory,
Rechargeable
Li-ion Battery
(4S2P)
-Battery Cell
(4S2P)
-Battery Cell
(4S2P)
- Top/Bottom
Enclosure for
battery pack
-Glue (for
Top/Bottom
Enclosure)
-Fuse (F1)
Page 36 of 50
BSC884N03MS
G
bq20Z45
Report Reference #
--
--
equip.
--
--
--
--
UL796
UL
--
Tested in the
equip.
UL1642
UL
UL1642
UL
UL94, UL 746C
UL
UL 746C
UL
UL 248-1,
UL 248-14,
EN 60127-1,
EN 60127-3
UL, TUV/Rh
(Certificate no.:
J 9650637)
--
V-1 min., min.
130 oC
Pegatron Corp. A42-A15
14.4 Vdc, 4400
mAh, 63 Wh or
14.6 Vdc,
52mAh, 75Wh
Samsung SDI
ICR18650-22++ 3.6Vdc,
Co Ltd
(++=These cells 2200mAh
(lithium type )
may have an
optional single
alphanumeric
suffix.)
LG Chemical Ltd ICR18650B3
3.65Vdc,
2600mAh
(lithium type )
Sabic Innovative BPL1000(C)
V-1 or better,
Plastics Japan L
min thick 0.7
LC
mm, 80 oC
Taiwan
LN-2250
Max. Temp
Cemedine co.,
Rating 60 oC.
Ltd.
Sony Chemicals SFH-1412#
12A, 36Vdc
Corp.
(# represents
suffix of
alphabetical
letter used for
internal
traceability)
Various
Various
10K ohm 25 oC
-Thermistor
(TH1)
-Mosfet (Q1, Q2) Infineon
Technologies
-Protection IC
Texas
(U1)
Instruments
-PCB
Various
Various
BSC884N03MS
G
bq20Z45
--
--
Tested in the
equip.
--
--
--
--
Various
V-1 min., min.
105 oC
5Vdc, 0.40A
max., 6.66 CFM
min.
See below for
detail
3Vdc, max.
abnormal
charging current
10mA
3Vdc, max.
abnormal
charging current
10mA
3Vdc, maximum
UL796
UL
UL507, EN
60950-1: 2006
UL 1642
UL, VDE
(Certificate no.:
40023247)
Tested in the
equip.
UL
UL 1642
UL
UL 1642
UL
DC Fan (for
CPU)
Delta Electronics KSB06105HB
Inc.
Mother Board
Pegatron Corp.
A15HC
- RTC Battery
(Lithium type)
Vic-Dawn
Enterprise Co.,
Ltd. / KTS
CR2032
CR2032
Shun Wo New
Power Battery
Technology Ltd. /
NewSun
Jhih Hong
CR2032
TRF No. IECEN60950_1C
ASL10120310
UL International Demko A/S
--
Issue Date:
2011-01-12
Page 37 of 50
Technology Co
Ltd
Various
CR2032
Global Mixedmode
Technology Inc.
G547
Tyco Electronics
Corp Raychem
Circuit Protection
Division
Shanghai Wayon
Thermo-Electro
Material Co., Ltd.
miniSMDC160xx
xxxxxxxxxxxxxxx
xxx (x= 0-9, A-Z,
“.”, “-“, blank)
LP-NSM035abc
(a=F or blank; b=
C, U or blank; c=
S, Z or blank)
Various
A15HC IO
BOARD
SMD1206P150T
FT
- Power
Distribution
Switch for USB
3.0 port (U5201,
U5202) use
(Optional when
F5201, F5203
provide)
- Polyswitch for
USB port
(F5201, F5203)
use
- Polyswitch for
HDMI port
(F5201, F5203)
use
- PCB
IO Board
Various
Pegatron Corp.
- Polyswitch for
USB port
(F6901) use
- PCB
Polytronics
Technology
Corp.
Various
Various
Report Reference #
abnormal
charging current
10 mA
UL
3Vdc, maximum UL 1642
abnormal
charging current
5mA min., user
replaceable
against charging
current by
multiple
components
D2001 and
R2001 rated 1
Kohm.
4.5-5.5Vdc, 1.1A IEC/EN 60950-1 CB by TUV/Rh
(Certificate no.:
JPTUV-017035)
9Vdc, 1.6A
EN 60730-1
UL, TUV
(Certificate no.:
R 72041438)
6Vdc, 0.35A
UL1434,
EN 60738-1,
EN 60738-1-1
UL, TUV
(Certificate No: R
50093334)
V-1 min. 105 oC
See below for
detail
8Vdc, 1.5A
UL796
--
UL
Tested in the
equip.
TUV/Rh
(Certificate no.
R50099121)
UL
V-1 min. 105 oC
1
UL 1434 /EN
60738-1/EN
607301-1
UL796
) an asterisk indicates a mark which assures the agreed level of surveillance
TRF No. IECEN60950_1C
ASL10120310
UL International Demko A/S
Issue Date:
1.6.2
2011-01-12
Page 38 of 50
Report Reference #
Pass
TABLE: electrical data (in normal conditions)
U (V)
--
I (A)
--
I rated (A)
--
P (W)
--
Fuse #
--
I fuse (A)
--
19Vdc
4.39
4.74
83.41
--
--
19Vdc
2.13
4.74
40.47
--
--
15.16Vdc
2.49
--
37.75
--
--
15.85Vdc
3.96
--
62.77
--
--
--
--
--
--
--
--
19Vdc
4.39
4.74
83.41
--
--
19Vdc
1.67
4.74
31.73
--
--
14.25Vdc
2.11
--
30.07
--
--
15.80Vdc
4.04
--
63.84
--
--
--
--
--
--
--
--
19Vdc
4.39
4.74
83.41
--
--
19Vdc
1.27
4.74
24.13
--
--
10.96Vdc
2.11
--
23.13
--
--
11.40Vdc
5.64
--
64.30
--
--
TRF No. IECEN60950_1C
ASL10120310
UL International Demko A/S
condition/status
MB: PEGATRON /A15HC,
Supplied by DC power source,
Battery Pack: PEGATRON /A42A15 (14.6Vdc, 5200mAh, 75Wh),
Maximum charge current: 3.5A,
Maximum discharge current:
5.2A, With VGA Chip, 2 core
CPU
Maximum normal load with empty
battery pack
System off with empty battery
pack charging mode
System off with empty battery
pack charging mode (Measure
battery pack connector)
Maximum normal load supplied by
battery pack discharge mode
(Measure battery pack connector)
MB: PEGATRON /A15HC,
Supplied by DC power source,
Battery Pack: PEGATRON /A42A15 (14.4Vdc, 4400mAh, 63Wh),
Maximum charge current:
3.01A, Maximum discharge
current: 5.2A, With VGA Chip, 2
core CPU
Maximum normal load with empty
battery pack
System off with empty battery
pack charging mode
System off with empty battery
pack charging mode (Measure
battery pack connector)
Maximum normal load supplied by
battery pack discharge mode
(Measure battery pack connector)
MB: PEGATRON /A15HC,
Supplied by DC power source,
Battery Pack: PEGATRON /A32A15 (10.8Vdc, 4400mAh, 47Wh),
Maximum charge current:
3.01A, Maximum discharge
current: 5.2A, With VGA Chip, 2
core CPU
Maximum normal load with empty
battery pack
System off with empty battery
pack charging mode
System off with empty battery
pack charging mode (Measure
battery pack connector)
Maximum normal load supplied by
Issue Date:
2011-01-12
Page 39 of 50
Report Reference #
--
--
--
--
--
--
19Vdc
4.36
4.74
82.84
--
--
19Vdc
2.12
4.74
40.28
--
--
14.93Vdc
2.57
--
38.38
--
--
15.94Vdc
4.28
--
68.23
--
--
--
--
--
--
--
--
19Vdc
4.36
4.74
82.84
--
--
19Vdc
1.73
4.74
32.87
--
--
14.19Vdc
2.19
--
31.08
--
--
15.53Vdc
4.35
--
67.56
--
--
--
--
--
--
--
--
19Vdc
4.36
4.74
82.84
--
--
19Vdc
1.34
4.74
25.46
--
--
10.85Vdc
2.19
--
23.77
--
--
11.49Vdc
6.02
--
69.17
--
--
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
battery pack discharge mode
(Measure battery pack connector)
MB: PEGATRON /A15HC,
Supplied by DC power source,
Battery Pack: PEGATRON /A42A15 (14.6Vdc, 5200mAh, 75Wh),
Maximum charge current: 3.5A,
Maximum discharge current:
5.2A, Without VGA Chip, 4 core
CPU
Maximum normal load with empty
battery pack
System off with empty battery
pack charging mode
System off with empty battery
pack charging mode (Measure
battery pack connector)
Maximum normal load supplied by
battery pack discharge mode
(Measure battery pack connector)
MB: PEGATRON /A15HC,
Supplied by DC power source,
Battery Pack: PEGATRON /A42A15 (14.4Vdc, 4400mAh, 63Wh),
Maximum charge current:
3.01A, Maximum discharge
current: 5.2A, Without VGA
Chip, 4 core CPU
Maximum normal load with empty
battery pack
System off with empty battery
pack charging mode
System off with empty battery
pack charging mode (Measure
battery pack connector)
Maximum normal load supplied by
battery pack discharge mode
(Measure battery pack connector)
MB: PEGATRON /A15HC,
Supplied by DC power source,
Battery Pack: PEGATRON /A32A15 (10.8Vdc, 4400mAh, 47Wh),
Maximum charge current:
3.01A, Maximum discharge
current: 5.2A, Without VGA
Chip, 4 core CPU
Maximum normal load with empty
battery pack
System off with empty battery
pack charging mode
System off with empty battery
pack charging mode (Measure
battery pack connector)
Maximum normal load supplied by
battery pack discharge mode
Issue Date:
2011-01-12
Page 40 of 50
Report Reference #
--
--
--
--
--
--
19Vdc
3.37
3.42
64.03
--
--
19Vdc
2.18
3.42
41.42
--
--
15.15Vdc
2.58
--
39.09
--
--
16.06Vdc
3.47
--
55.73
--
--
--
--
--
--
--
--
19Vdc
3.37
3.42
64.03
--
--
19Vdc
1.70
3.42
32.30
--
--
14.24Vdc
2.19
--
31.19
--
--
15.74Vdc
3.56
--
56.04
--
--
--
--
--
--
--
--
19Vdc
3.37
3.42
64.03
--
--
19Vdc
1.33
3.42
25.27
--
--
10.94Vdc
2.19
--
23.96
--
--
11.62Vdc
4.92
--
57.18
--
--
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
(Measure battery pack connector)
MB: PEGATRON /A15HC,
Supplied by DC power source,
Battery Pack: PEGATRON /A42A15 (14.6Vdc, 5200mAh, 75Wh),
Maximum charge current: 3.5A,
Maximum discharge current:
5.2A, Without VGA Chip, 2 core
CPU
Maximum normal load with empty
battery pack
System off with empty battery
pack charging mode
System off with empty battery
pack charging mode (Measure
battery pack connector)
Maximum normal load supplied by
battery pack discharge mode
(Measure battery pack connector)
MB: PEGATRON /A15HC,
Supplied by DC power source,
Battery Pack: PEGATRON /A42A15 (14.4Vdc, 4400mAh, 63Wh),
Maximum charge current:
3.01A, Maximum discharge
current: 5.2A, Without VGA
Chip, 2 core CPU
Maximum normal load with empty
battery pack
System off with empty battery
pack charging mode
System off with empty battery
pack charging mode (Measure
battery pack connector)
Maximum normal load supplied by
battery pack discharge mode
(Measure battery pack connector)
MB: PEGATRON /A15HC,
Supplied by DC power source,
Battery Pack: PEGATRON /A32A15 (10.8Vdc, 4400mAh, 47Wh),
Maximum charge current:
3.01A, Maximum discharge
current: 5.2A, Without VGA
Chip, 2 core CPU
Maximum normal load with empty
battery pack
System off with empty battery
pack charging mode
System off with empty battery
pack charging mode (Measure
battery pack connector)
Maximum normal load supplied by
battery pack discharge mode
(Measure battery pack connector)
Issue Date:
2011-01-12
Page 41 of 50
Report Reference #
ASL10120310
supplementary information:
Maximum normal load: The unit reads and writes in HDD and operating continuously. Each USB2.0 port is
loaded with 2.5W and USB3.0 port is loaded with 4.5W. Run CPU program until performance to 100%. LED
backlight with max. Brightness, max. Volume of speaker, battery pack is empty.
2.10.3 and
2.10.4
Pass
TABLE: clearance and creepage distance measurements
Clearance (cl) and creepage
distance (cr) at/of/between:
--
U peak
(V)
--
U r.m.s.
(V)
--
Required cl
cl
(mm)
(mm)
---
Required cr
cr
(mm)
(mm)
---
supplementary information:
Functional Insulation, see clause 5.3.4.
2.10.5
N/A
TABLE: distance through insulation measurements
Distance through insulation (DTI) at/of:
U peak
(V)
Urms
(V)
Test voltage Required DTI
(V)
(mm)
DTI
(mm)
supplementary information:
4.3.8
Pass
TABLE: Batteries
The tests of 4.3.8 are applicable only when appropriate
battery data is not available.
--
---
Is it possible to install the battery in a reverse polarity position No
Non-rechargeable batteries
Discharging
Meas.
current
Battery
Pack:
PEGATRO
N /A32A15
(10.8Vdc,
4400mAh,
47Wh)
Max.
current
Rapid
dischargin
g [Q1 (1-8)
Unintentional
charging
Manuf.
specs.
Rechargeable batteries
Charging
Meas. current
Discharging
Manuf.
specs.
Meas.
current
Manuf.
specs.
Reversed
charging
Meas.
current
Manuf.
specs.
--
--
--
--
--
--
--
--
--
--
--
--
--
--
6.02A
5.2A
--
--
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
short]
Battery
Pack:
PEGATRO
N /A42A15
(14.6Vdc,
5200mAh,
75Wh,
Cell: LG
CHEMICA
L LTD
/ICR18650
B3)
Max.
current
during
normal
condition
Max.
current
during fault
condition
Battery
Pack:
PEGATRO
N /A42A15
(14.4Vdc,
4400mAh,
63Wh,
Cell:
SAMSUN
G SDI CO
LTD
/ICR18650
-22F)
Max.
current
during
normal
condition
Max.
current
during fault
condition
Battery
Pack:
PEGATRO
N /A32A15
(10.8Vdc,
4400mAh,
47Wh,
2011-01-12
Page 42 of 50
Report Reference #
ASL10120310
--
--
--
--
--
--
--
--
--
--
--
--
3.5 A
C.C.
mode ,
3.5 A
5.2 A
5.2 A
--
--
5.2 A
Q1 (18) short
/ 5.2 A
--
--
--
--
--
3.5 A
Q2 (18) short
/ C.C.
mode ,
3.5 A
--
--
--
--
--
--
--
--
--
--
--
--
3.01 A
C.C.
mode ,
3.01 A
5.2 A
5.2 A
--
--
5.2 A
Q1(1-8)
short /
5.2 A
--
--
--
--
--
--
--
--
--
3.01 A
Q2 (18) short
/ C.C.
mode ,
3.01 A
--
--
--
--
--
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
Cell:
SAMSUN
G SDI CO
LTD
/ICR18650
-22F)
Max.
current
during
normal
condition
Max.
current
during fault
condition
2011-01-12
--
--
--
--
Page 43 of 50
--
--
Report Reference #
3.01 A
C.C.
mode ,
3.01 A
3.01 A
Q2 (18) short
/ C.C.
mode ,
3.01 A
ASL10120310
5.2 A
5.2 A
--
--
5.2 A
Q1 (18) short
/
5.2 A
--
--
Test results:
--
- Chemical leaks
No such result occurred
Pass
- Explosion of the battery
No such result occurred
Pass
- Emission of flame or expulsion of molten metal
No such result occurred
Pass
Verdict
- Electric strength tests of equipment after completion of tests --
N/A
supplementary information:
For RTC battery and without battery charging circuit. About the detail for the fault conditions and result, please
see appended table 5.3.
4.5
Pass
TABLE: Thermal requirements
Supply voltage (V)........................................... :
Ambient Tmin (oC) .......................................... :
Ambient Tmax (oC) ......................................... :
see
below
--
see
below
--
see
below
--
see
below
--
see
below
see
below
see
below
see
below
TRF No. IECEN60950_1C
—
--
—
--
—
--
allowed
Tmax
(oC)
--
--------
-105
105
100
60
75
60
T (oC)
Maximum measured temperature T of part/at:
Normal Condition
MB: PEGATRON /A15HC, Adapter: Delta /ADP90CD DB, Battery Pack: PEGATRON/ A42-A15
(14.6Vdc, 5200mAh, 75Wh), CPU fan: Delta
Electronics Inc /KSB06105HB, With VGA Chip, 2
core CPU
1.Ambient
2.PWB near CPU
3.PWB near North Bridge Chip
4.RTC battery body
5.Enclosure inside near CPU
6.Enclosure outside near CPU
7.Enclosure near battery connector
--
Conditi Conditi Conditi Conditi
on 1
on 1
on 2
on 2
(Origin (Shift (Origin (Shift
al)
to 35)
al)
to 35)
27.1
52.0
53.7
50.7
38.3
35.7
31.9
35.0
59.9
61.6
58.6
46.2
43.6
39.8
UL International Demko A/S
26.8
60.0
59.0
54.0
46.0
43.0
46.0
35.0
68.2
67.2
62.2
54.2
51.2
54.2
Issue Date:
2011-01-12
Page 44 of 50
8.Battery Pack body
9.PTC body (F6901)
10.PWB near VGA Chip
Normal Condition
MB: PEGATRON /A15HC, Adapter: Delta /ADP90CD DB, Battery Pack: PEGATRON/ A42-A15
(14.6Vdc, 5200mAh, 75Wh), CPU fan: Delta
Electronics Inc /KSB06105HB, Without VGA Chip,
4 core CPU
1.Ambient
2.PWB near CPU
3.PWB near North Bridge Chip
4.RTC battery body
5.Enclosure inside near CPU
6.Enclosure outside near CPU
7.Enclosure near battery connector
8.Battery Pack body
9.PTC body (F6901)
Normal Condition
Battery pack discharge mode 6.02A, Battery Pack
Model: A32-A15 (10.8Vdc, 4400mAh, 47Wh)
1.Ambient
2.Cell body
3.PWB near Q1
4.PWB near R38
5.Enclosure inside near Q1
6.Enclosure outside near Q1
7.Enclosure inside near R38
8.Enclosure outside near R38
Normal Condition
Battery Pack: PEGATRON/ A42-A15 (14.6Vdc,
5200mAh, 75Wh, Cell: LG CHEMICAL LTD
/ICR18650B3), Maximum charging voltage:
17.0Vdc, Maximum charging current: 3.5A,
Maximum discharging current: 5.2A
1.Ambient
2.Enclosure outside near Q1,Q2
3.Enclosure inside near Q1,Q2
4.Cell body
5.PWB near Q1,Q2
Normal Condition
Battery Pack: PEGATRON/ A42-A15 (14.4Vdc,
4400mAh, 63Wh, Cell: SAMSUNG SDI CO LTD
/ICR18650-22F), Maximum charging voltage:
17.0Vdc, Maximum charging current: 3.01A,
Maximum discharging current: 5.2A
1.Ambient
2.Enclosure outside near Q1,Q2
3.Enclosure inside near Q1,Q2
4.Cell body
5.PWB near Q1,Q2
Normal Condition
Battery Pack: PEGATRON/ A32-A15 (14.4Vdc,
4400mAh, 63Wh, Cell: SAMSUNG SDI CO LTD
TRF No. IECEN60950_1C
Report Reference #
ASL10120310
29.6
37.5
46.5
54.7
33.1
41.0
35.0
43.2
49.6
57.5
57.0
65.2
Conditi Conditi Conditi Conditi
on 4
on 4
on 3
on 3
(Origin (Shift (Origin (Shift
to 35)
al)
to 35)
al)
-----
75
85
105
--
26.0
35.0
25.7
35.0
55.7
64.7
53.0
62.3
54.9
63.9
51.0
60.3
50.1
59.1
48.0
57.3
38.8
47.8
42.5
51.8
35.6
44.6
39.0
48.3
30.2
39.2
43.0
52.3
28.5
37.5
46.0
55.3
32.4
41.4
32.0
41.3
Conditi Conditi
--on 5
on 5
(Origin (Shift
al)
to 35)
24.9
35.0
--49.0
59.1
--75.0
85.1
--61.0
71.1
--60.5
70.6
--48.0
58.1
--52.0
62.1
--44.5
54.6
--Conditi Conditi Conditi Conditi
on 6
on 6
on 7
on 7
(Origin (Shift (Origin (Shift
al)
to 35)
al)
to 35)
-----------
-105
105
100
60
75
60
75
85
--
----------
-100
105
105
80
60
80
60
--
39.3
-39.2
-42.0
-51.0
-43.0
-54.0
-44.0
-60.0
-47.0
-63.0
-Conditi Conditi Conditi Conditi
on 9
on 9
on 8
on 8
(Origin (Shift (Origin (Shift
to 35)
al)
to 35)
al)
-------
-75
80
100
105
--
39.5
-39.8
-42.0
-48.0
-44.0
-55.0
-46.0
-56.0
-46.0
-63.0
-Conditi Conditi Conditi Conditi
on 10 on 10 on 11 on 11
(Origin (Shift (Origin (Shift
------
-75
80
100
105
--
UL International Demko A/S
Issue Date:
2011-01-12
Page 45 of 50
/ICR18650-22F), Maximum charging voltage:
17.0Vdc, Maximum charging current: 3.01A,
Maximum discharging current: 5.2A
1.Ambient
2.Enclosure outside near Q1,Q2
3.Enclosure inside near Q1,Q2
4.Cell body
5.PWB near Q1,Q2
temperature T of winding:
--
t1 (oC)
--
Report Reference #
ASL10120310
al)
to 35)
al)
to 35)
39.3
42.0
44.0
45.0
46.0
------
39.3
48.0
52.0
55.0
58.0
------
R1 ()
t2 (oC)
R2 ( )
T (oC)
--
--
--
--
------
-75
80
100
105
allowed insulation
Tmax
class
(oC)
---
supplementary information:
MB: PEGATRON /A15HC, Adapter: Delta /ADP-90CD DB, Battery Pack: PEGATRON /A42-A15
(14.6Vdc, 5200mAh, 75Wh), CPU fan: Delta Electronics Inc /KSB06105HB, With VGA Chip, 2 core CPU
Test Condition 1: Maximum normal load 19Vdc with empty battery pack, Duration 2hrs.56mins.
Test Condition 2: Maximum normal load with full battery pack discharge mode, Duration 2hrs.4mins.
MB: PEGATRON /A15HC, Adapter: Delta /ADP-90CD DB, Battery Pack: PEGATRON /A42-A15
(14.6Vdc, 5200mAh, 75Wh), CPU fan: Delta Electronics Inc /KSB06105HB, Without VGA Chip, 4 core
CPU
Test Condition 3: Maximum normal load 19Vdc with empty battery pack, Duration 2hrs.21mins.
Test Condition 4: Maximum normal load with full battery pack discharge mode, Duration 1hrs.57mins.
Battery pack discharge mode 6.02A, Battery Pack Model: A32-A15 (10.8Vdc, 4400mAh, 47Wh)
Test Condition 5: Battery pack discharge mode 6.02A, Duration 1hrs.25mins.
Battery Pack: PEGATRON /A42-A15 (14.6Vdc, 5200mAh, 75Wh, Cell: LG CHEMICAL LTD
/ICR18650B3), Maximum charging voltage: 17.0Vdc, Maximum charging current: 3.5A, Maximum
discharging current: 5.2A
Test Condition 6: Charging Test, Duration 2hrs.21mins.
Test Condition 7: Discharging test, Duration 1hrs.50mins.
Battery Pack: PEGATRON /A42-A15 (14.4Vdc, 4400mAh, 63Wh, Cell: SAMSUNG SDI CO LTD
/ICR18650-22F), Maximum charging voltage: 17.0Vdc, Maximum charging current: 3.01A, Maximum
discharging current: 5.2A
Test Condition 8: Charging Test, Duration 2hrs.25mins.
Test Condition 9: Discharging test, Duration 1hrs.51mins.
Battery Pack: PEGATRON /A32-A15 (10.8Vdc, 4400mAh, 47Wh, Cell: SAMSUNG SDI CO LTD
/ICR18650-22F), Maximum charging voltage: 12.75Vdc, Maximum charging current: 3.01A, Maximum
discharging current: 5.2A
Test Condition 10: Charging Test, Duration 2hrs.13mins.
Test Condition 11: Discharging test, Duration 1hrs.48mins.
The temperatures were measured under worst case normal mode defined in 1.2.2.1 and described in 1.6.2
at voltages as described in 1.4.5
Without specified ambient temperature in users manual, therefore the ambient temperature assumed as 35
degree C, the max. allowed temperature is listed as follows:
Components with:
Max.temp.of 105°C (PWB)
Max.temp.of 100°C (RTC,Cell)
Max.temp.of 85°C (PTC)
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 46 of 50
Report Reference #
ASL10120310
Max.temp.of 60°C (Enclosure for Notebook)
Max.temp.of 80°C (Enclosure for Battery Pack)
User accessible area:
Material is plastic 75°C
4.5.5
TABLE: Ball pressure test of thermoplastic parts
N/A
allowed allowed impression diameter (mm)........... :
—
part
test temperature (°C)
impression diameter
(mm)
supplementary information:
4.7
Pass
TABLE: resistance to fire
part
manufacturer of
material
--
--
type of material
thickness flammability
(mm)
class
---
--
Evidence
supplementary information:
See table 1.5.1 for detail.
5.2
N/A
TABLE: electric strength tests, impulse tests and voltage surge tests
Test voltage applied between:
Voltage shape
(AC, DC,
impulse, surge)
Test voltage
(V)
Breakdown
Yes / No
supplementary information:
--
5.3
Pass
TABLE: fault condition tests
ambient temperature (°C) ....................................... :
See below
Power source for EUT: Manufacturer, model/type,
output rating ............................................................ :
see appended table 1.5.1
Component
No.
Fault
Supply
voltage
(V)
Test time
Fuse
#
Fuse current
(A)
---
---
---
---
---
---
Rapid
Short
12.75Vdc
7hrs.
--
--
TRF No. IECEN60950_1C
UL International Demko A/S
—
—
Observation
4.3.8 - BATTERY TESTS
Battery Pack:
PEGATRON/ A32-A15
(10.8Vdc, 4400mAh,
47Wh)
Max. Discharging
Issue Date:
2011-01-12
Page 47 of 50
discharge
Q1 (1-8)
--
Report Reference #
0mins.
--
--
--
--
--
-None
(overcharg
e test)
24Vdc
8hrs.
08mins.
--
--
Q2 1-8
short
(overcharg
e test)
24Vdc
8hrs.
08mins.
--
--
Q1 1-8
(discharge
test)
short
17.0Vdc
19hrs.
04mins.
--
--
Battery
Pack
Output + -
short
17.0Vdc
19hrs.
04mins.
--
--
--
--
--
--
--
--
None
-(overcharg
e test)
24Vdc
8hrs.
07mins.
--
--
Q2 1-8
short
(overcharg
e test)
24Vdc
8hrs.
07mins.
--
--
Q1 1-8
(discharge
17.0Vdc
7hrs.
34mins.
--
--
short
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
voltage=12.75Vdc, Max.
Discharging current=6.02A,
No damage, No hazards,
F1 open, Cell body=49.0
degree C, PWB near
Q1=75.5 degree C,
Ambient=25.8 degree C.
Battery Pack:
PEGATRON/ A42-A15
(14.6Vdc, 5200mAh,
75Wh, Cell: LG
CHEMICAL LTD
/ICR18650B3)
Test by C.C. mode(3.5A),
No damage, No hazards,
Ambient=21.3 degree C,
Cell body = 21.7 degree C,
PWB near Q1,Q2 = 21.7
degree C.
Test by C.C. mode(3.5A),
F1 open, No hazards,
Ambient=21.3 degree C,
Cell body=23.0 degree C,
PWB near Q1,Q2=26.0
degree C.
Discharge current 5.2A, F1
open, No hazards,
Ambient=20.8 degree C,
Cell body=66.0 degree C,
PWB near Q1,Q2=98.0
degree C.
No damage, No hazards,
Ambient=20.8 degree C,
Cell body=20.9 degree C,
PWB near Q1,Q2=21.0
degree C.
Battery Pack:
PEGATRON/ A42-A15
(14.4Vdc, 4400mAh,
63Wh, Cell: SAMSUNG
SDI CO LTD/ ICR1865022F)
Test by C.C. mode(3.01A),
No damage, No hazards,
Ambient=22.3 degree C,
Cell body=22.5 degree C,
PWB near Q1,Q2=22.6
degree C.
Test by C.C. mode(3.01A),
F1 open, No hazards,
Ambient=22.3 degree C,
Cell body=23.7 degree C,
PWB near Q1,Q2=26.9
degree C.
Discharge current 5.2A, F1
open, No hazards,
Issue Date:
2011-01-12
Page 48 of 50
Report Reference #
ASL10120310
Battery
Pack
Output + -
short
17.0Vdc
7hrs.
34mins.
--
--
--
--
--
--
--
--
None
-(overcharg
e test)
18.0Vdc
8hrs.
15mins.
--
--
Q2 S-D
short
(overcharg
e test)
18.0Vdc
8hrs.
15mins.
--
--
Q1 S-D
(discharge
test)
short
12.75Vdc
7hrs.
15mins
--
--
Battery
Pack
Output + -
short
12.75Vdc
7hrs.
15mins
--
--
--
--
--
--
--
--
--
-Normal
-19Vdc
---
---
---
Ambient=22.5 degree C,
Cell body=48.0 degree C,
PWB near Q1,Q2=59.0
degree C.
No damage, No hazards,
Ambient=22.5 degree C,
Cell body=22.6 degree C,
PWB near Q1,Q2=22.7
degree C.
Battery Pack:
PEGATRON/ A32-A15
(10.8Vdc, 4400mAh,
47Wh, Cell: SAMSUNG
SDI CO LTD/ ICR1865022F)
Test by C.C mode(3.01 A),
No damage, No hazards,
Ambient=22.1 degree C,
Cell body=22.2 degree C,
PWB near Q1,Q2=22.2
degree C.
Test by C.C mode(3.01 A),
F1 open, No hazards,
Ambient=22.1 degree C,
Cell body=22.9 degree C,
PWB near Q1,Q2=25.4
degree C.
Discharge current=5.2A, F1
open, No hazards,
Ambient=21.9 degree C,
Cell body=48.0 degree C,
PWB near Q1,Q2=56.0
degree C.
No damage, No hazards,
Ambient=21.9 degree C,
Cell body=22.0 degree C,
PWB near Q1,Q2=22.1
degree C.
4.3.8-LITHIUM BATTERY
REVERSE CURRENT
MEASUREMENT TEST
MB: PEGATRON/A15HC
Charging current is 0.1mA
19Vdc
--
--
--
Charging current is 0.1mA
19Vdc
--
--
--
Charging current is 3.4mA
test)
RTC
battery
reverse
current test
Short
RTC
battery
reverse
current test
R2001
Short
RTC
battery
reverse
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 49 of 50
Report Reference #
ASL10120310
current test
D2001 (12)
RTC
battery
reverse
current test
D2001 (23)
RTC
battery
(C2003) for
Vic-Dawn
Enterprise
Co., Ltd. /
KTS /type:
CR2032
RTC
battery
(C2003) for
Shun Wo
New Power
Battery
Technolog
y Ltd. /
NewSun
/type:
CR2032
RTC
battery
(C2003) for
Jhih Hong
Technolog
y Co Ltd
/type:
CR2032
--
Short
19Vdc
--
--
--
Charging current is 3.0mA
Short
3Vdc
7hrs.
--
--
Maximum Discharge
Current 2.88mA, No
hazardous.
Short
3Vdc
7hrs.
--
--
Maximum Discharge
Current 2.88mA, No
hazardous.
Short
3Vdc
7hrs.
--
--
Maximum Discharge
Current 2.88mA, No
hazardous.
--
--
--
--
--
--
--
--
--
--
--
1.CPU fan
Stalled
19Vdc
2hrs.43min -s.
--
19Vdc
1hrs.55min -s.
--
5.3.1-5.3.9-ABNORMAL
OPERATION TESTS
MB: PEGATRON /A15HC,
Adapter: Delta /ADP90CD DB, Battery Pack:
PEGATRON/ A42-A15
(14.6Vdc, 5200mAh,
75Wh), CPU fan: Delta
Electronics Inc
/KSB06105HB, With VGA
Chip, 2 core CPU
NT.NC.CT. Normal
operation. No hazardous.
Maximum Temp: PWB near
North Bridge Chip=75.2
degree C, Ambient=26.6
degree C.
NT.NC. Unit shutdown. No
hazardous. Maximum
2.Ventilatio Blocked
n openings
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 50 of 50
Report Reference #
ASL10120310
Temp: PWB near North
Bridge Chip=76.5 degree
C, Ambient=25.0 degree C.
supplementary information:
Comments Key: (COMPONENT FAILURE TEST; ABNORMAL OPERATION TEST; TRANSFORMER
ABNORMAL OPERATION TEST) IP - Internal protection operated (list component), CT - Constant
temperatures were obtained, CD - Components damaged (list damaged components), NB - No indication of
dielectric breakdown, NT - Tissue paper remained intact, NC - Cheesecloth remained intact, (OVERLOAD
OF OPERATOR ACCESSIBLE CONNECTOR TEST) C - Circuit measures less than 12.5mA, B - Circuit
measures 0 Volts
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 1 of 21
Report Reference #
Enclosure
National Differences
Australia*
Austria**
Belgium**
Czech Republic**
Denmark
Finland
France**
Germany
Greece**
Group
Hungary**
Ireland
Italy**
Japan*
Korea
Netherlands**
Norway
Poland**
Portugal**
Slovakia**
Slovenia**
Spain
Sweden
Switzerland
USA / Canada
United Kingdom
*
No National Differences
Declared
** Only Group Differences
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 2 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Denmark - Differences to IEC 60950-1:2005, Second Edition
1.2.4.1
Certain types of Class I appliances (see sub-clause
3.2.1.1) may be provided with plug not establishing
earthing continuity when inserted into Danish
socket-outlets.
N/A
1.7.2.1
Supply cords of Class I equipment, which is
delivered without a plug, must be provided with a
visible tag with the following text:
N/A
"Vigtigt !
Lederen med gron/gul isolation ma kun
tilsluttes en klemme market
(IEC 417, No. 5019) eller (IEC 417, No. 5017)."
If essential for the safety of the equipment, the tag
must in addition be provided with a diagram, which
shows the connection of the other conductors, or
be provided with the following text:
"For tilslutning af de ovrige ledere, se medfolgende
installationsvejledning".
1.7.5
Socket-outlets for providing power to other
equipment shall be in accordance with the Heavy
Current Regulations, Section 107-2-D1, Standard
Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on
Class I equipment. For stationary equipment, the
socket0outlet shall be in accordance with Standard
Sheet DK 1-1b or DK 1-5a.
N/A
1.7.5
With the exception of CLASS II EQUIPMENT
provided with a socket outlet in accordance with
the Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-4a, CLASS II EQUIPMENT
shall not be fitted with socket-outlets for providing
power to other equipment.
N/A
3.2.1.1
Supply cord of single-phase equipment having a
rated current not exceeding 13 A shall be provided
with a plug according to the Heavy Current
Regulations, Section 107-2-D1.
N/A
Class I equipment provided with socket-outlets with
earth contact or which are intended to be used in
locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase
equipment having a rated current exceeding 13 A
is provided with a supply cord with a plug, this plug
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 3 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
shall be in accordance with the Heavy Current
Regulations, Section 107-2-D1 or EN 60309-2.
5.1.7.1
TOUCH CURRENT measurement results
exceeding 3,5 mA r.m.s. are permitted only for
PERMANENTLY CONNECTED EQUIPMENT and
PLUGGABLE EQUIPMENT TYPE B.
N/A
Finland - Differences to IEC 60950-1:2005, Second Edition
1.5.7.1
Resistors bridging BASIC INSULATION in CLASS I
PLUGGABLE EQUIPMENT TYPE A must comply
with the requirements in 1.5.7.2.
N/A
1.5.9.4
The third dashed sentence is applicable only to
equipment as defined by this annex, 6.1.2.2
N/A
1.7.2.1
Class I Pluggable Equipment Type A intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet. The
marking text shall be:
"Laite on liitettava suojamaadoitus-koskettimilla
varustettuun pistorasiaan"
N/A
2.3.2
Requirements according to this annex, 6.1.2.1 and
6.1.2.2 apply.
N/A
2.10.5.13
Requirements according to this annex, 6.1.2.1 and
6.1.2.2 apply.
N/A
5.1.7.1
Touch current measurement results exceeding 3,5
mA r.m.s are permitted only for the following
equipment:
- Stationary pluggable equipment Type A that: (1)
is intended to be used in a Restricted Access
Location where equipotential bonding has been
applied, for example, in a telecommunication
centre; and (2) has provision for a permanently
connected protective earthing conductor; and (3) is
provided with instructions for the installation of that
conductor by a service person;
- Stationary pluggable equipment Type B
- Stationary permanently connected equipment
N/A
6.1.2.1
Add the following text between the first and second
paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least consist
of either
- two layers of thin sheet material, each of which
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 4 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that CLEARANCES
and CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below and
in addition
- passes the tests and inspection criteria of 2.10.11
with an electric strength test of 1,5 kV multiplied by
1,6 (the electric strength test of 2.10.10 shall be
performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test voltage
of 1,5 kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to EN
132400:1994, may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
132400, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in EN
60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all the
test specimens as described in EN 132400;
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400, in the
sequence of tests as described in EN 132400.
6.1.2.2
The exclusions are applicable for permanently
connected equipment and pluggable equipment
type B and equipment intended to be used in a
restricted access location where equipotential
bonding has been applied, e.g. in a
telecommunication centre, and which has provision
for a permanently connected protective earthing
conductor and is provided with instructions for the
installation of that conductor by a service person.
N/A
7.2
Requirements according to this annex, 6.1.2.1 and
6.1.2.2 apply with the term telecommunication
network in 6.1.2 being replaced by the term cable
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 5 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
distribution system.
Germany - Differences to IEC 60950-1:2005, Second Edition
1.7.2.1
If for the assurance of safety and health certain
rules during use, amending or maintenance of a
technical labour equipment or readymade
consumer product are to be followed, a manual in
German language has to be delivered when
placing the product on the market. Of this
requirement, rules for use even only by SERVICE
PERSONS are not exempted.
N/A
Group - Differences to IEC 60950-1:2005, Second Edition
1.3.Z1
Exposure to excessive sound pressure - The
apparatus shall be so designed and constructed as
to present no danger when used for its intended
purpose, either in normal operating conditions or
under fault conditions, particularly providing
protection against exposure to excessive sound
pressures from headphones or earphones.
NOTE Z1 A new method of measurement is
described in EN 50332-1, Sound system
equipment: Headphones and earphones
associated with portable audio equipment Maximum sound pressure level measurement
methodology and limit considerations - Part 1:
General method for ¡§one package equipment¡¨,
and in EN 50332-2, Sound system equipment:
Headphones and earphones associated with
portable audio equipment - Maximum sound
pressure level measurement methodology and limit
considerations - Part 2: Guidelines to associate
sets with headphones coming from different
manufacturers.
N/A
1.5.1
Add the following NOTE Z1: The use of certain
substances in electrical and electronic equipment is
restricted within the EU: see Directive 2002/95/EC
N/A
1.7.2.1
Add the following NOTE Z1: In addition, the
instructions shall include, as far as applicable, a
warning that excessive sound pressure from
earphones and headphones can cause hearing
loss.
N/A
2.7.1
Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-circuits
and earth faults in primary circuits, protective
devices shall be included either as integral parts of
the equipment or as parts of the building
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 6 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
installation, subject to the following, a), b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the requirements
of 5.3 shall be included as parts of the equipment;
b) for components in series with the mains input to
the equipment such as the supply cord, appliance
coupler, r.f.i. filter and switch, short-circuit and
earth fault protection may be provided by protective
devices in the building installation;
c) it is permitted for pluggable equipment type B or
permanently connected equipment, to rely on
dedicated overcurrent and short-circuit protection in
the building installation, provided that the means of
protection, e.g. fuses or circuit breakers, is fully
specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for pluggable equipment type A
the building installation shall be regarded as
providing protection in accordance with the rating
of the wall socket outlet.
2.7.2
Void
N/A
3.2.3
Delete the NOTE and conduit sizes in parentheses
in Table 3A
N/A
3.2.5.1
Replace:
"60245 IEC 53" by "H05 RR-F"
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F"
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F"
N/A
In table 3B, replace the first four lines by the
following:
Up to and including 6
0.75 a)
Over 6 up to and including 10 0.75 b) 1.0
Over 10 up to and including 16 1.0 c)
1.5
In the conditions applicable to table 3B, delete the
words "in some countries" in condition a).
In Note 1, applicable Table 3B, to delete the
second sentence.
3.3.4
In table 3D, delete the fourth line: conductor sizes
for 10 to 13 A, and replace with the following:
"Over 10 up to and
including 16
1.5 to 2.5 1.5 to by 4"
N/A
Delete the fifth line: conductor sizes for 13 to 16A.
4.3.13.6
Add the following NOTE Z1: Attention is drawn to
1999/519/EC: Council Recommendation on the
limitation of exposure of the general public to
electromagnetic fields 0 Hz to 300 GHz. Standards
TRF No. IECEN60950_1C
UL International Demko A/S
N/A
Issue Date:
2011-01-12
Page 7 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
taking into account this Recommendation which
demonstrate compliance with the applicable EU
Directive are indicated in the OJEC.
H
Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the operator
access area, the dose rate shall not exceed 1
£gSv/h (0,1 mR/h) (see note). Account is taken of
the background level.
Replace the notes as follows:
NOTE - These values appear in Directive
96/29/Euratom.
Delete Note 2.
N/A
Ireland - Differences to IEC 60950-1:2005, Second Edition
3.2.1.1
Apparatus which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to I.S. 411 by means of that
flexible cable or cord and plug, shall be fitted with a
13 A plug in accordance with Statutory Instrument
525:1997 - National Standards Authority of Ireland
(section 28) (13 A Plugs and Conversion Adaptors
for Domestic Use) Regulations 1997.
N/A
4.3.6
DIRECT PLUG-IN EQUIPMENT is known as plug
similar devices. Such devices shall comply with
Statutory Instrument 526:1997 - National
Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and sockets
for domestic use) Regulations, 1997.
N/A
Korea - Differences to IEC 60950-1:2005, Second Edition
1.5.101
Plugs for the connection of the apparatus to the
mains supply shall comply withe the Korean
requirement (KSC 8305)
N/A
8
EMC - The apparatus shall comply with the
relevant CISPR standards
N/A
Norway - Differences to IEC 60950-1:2005, Second Edition
1.5.7.1
Resistors bridging BASIC INSULATION in CLASS I
PLUGGABLE EQUIPMENT TYPE A must comply
with the requirements in 1.5.7.2.
N/A
1.5.8
Due to the IT power system used (see annex V,
figure V.7), capacitors are required to be rated for
the applicable phase-to-phase voltage ( 230 V).
N/A
1.5.9.4
The third dashed sentence is applicable only to
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 8 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
equipment as defined by this annex, 6.1.2.2
1.7.2.1
Class I Pluggable Equipment Type A intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet. The
marking text shall be:
"Apparatet ma tilkoples jordet stikkontakt"
N/A
2.2.4
Requirements according to this annex, 1.7.2.1,
6.1.2.1 and 6.1.2.2 apply.
N/A
2.3.2
Requirements according to this annex, 6.1.2.1 and
6.1.2.2 apply.
N/A
2.3.4
Requirements according to this annex, 1.7.2.1,
6.1.2.1 and 6.1.2.2 apply.
N/A
2.10.5.13
Requirements according to this annex, 6.1.2.1 and
6.1.2.2 apply.
N/A
5.1.7.1
Touch current measurement results exceeding 3,5
mA r.m.s are permitted only for the following
equipment:
- Stationary pluggable equipment Type A that: (1)
is intended to be used in a Restricted Access
Location where equipotential bonding has been
applied, for example, in a telecommunication
centre; and (2) has provision for a permanently
connected protective earthing conductor; and (3) is
provided with instructions for the installation of that
conductor by a service person;
- Stationary pluggable equipment Type B
- Stationary permanently connected equipment
N/A
6.1.2.1
Add the following text between the first and second
paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least consist
of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below.
N/A
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that CLEARANCES
and CREEPAGE DISTANCES do not exist, if the
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 9 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
component passes the electric strength test in
accordance with the compliance clause below and
in addition
- passes the tests and inspection criteria of 2.10.11
with an electric strength test of 1,5 kV multiplied by
1,6 (the electric strength test of 2.10.10 shall be
performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test voltage
of 1,5 kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to EN
132400:1994, may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
132400, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in EN
60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all the
test specimens as described in EN 132400;
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400, in the
sequence of tests as described in EN 132400.
6.1.2.2
The exclusions are applicable for permanently
connected equipment and pluggable equipment
type B and equipment intended to be used in a
restricted access location where equipotential
bonding has been applied, e.g. in a
telecommunication centre, and which has provision
for a permanently connected protective earthing
conductor and is provided with instructions for the
installation of that conductor by a service person.
N/A
7.2
Requirements according to this annex, 6.1.2.1 and
6.1.2.2 apply with the term telecommunication
network in 6.1.2 being replaced by the term cable
distribution system.
N/A
7.3
There are many buildings where the screen of the
coaxial cable is not normally connected to the earth
in the building installation
N/A
7.3
Refer to EN 60728-11:2005 for installation
conditions
N/A
Spain - Differences to IEC 60950-1:2005, Second Edition
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 10 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
3.2.1.1
Supply cords of single-phase equipment having a
rated current not exceeding 10 A shall be provided
with a plug according to UNE 20315:1994. Supply
cords of single-phase equipment having a rated
current not exceeding 2,5 A shall be provided with
a plug according to UNE-EN 50075:1993.
Verdict
N/A
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be
used in locations where protection against indirect
contact is required according to the wiring rules,
shall be provided with a plug in accordance with
standard UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
Sweden - Differences to IEC 60950-1:2005, Second Edition
1.5.1
(Ordinance (1990:944)) Add NOTE: Switches
containing mercury such as thermostats, relays
and level controllers are not allowed.
N/A
1.5.7.1
Resistors bridging BASIC INSULATION in CLASS I
PLUGGABLE EQUIPMENT TYPE A must comply
with the requirements in 1.5.7.2.
N/A
1.5.9.4
The third dashed sentence is applicable only to
equipment as defined by this annex, 6.1.2.2
N/A
1.7.2.1
Class I Pluggable Equipment Type A intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet. The
marking text shall be:
"Apparaten skall anslutas till jordat uttag"
N/A
2.3.2
Requirements according to this annex, 6.1.2.1 and
6.1.2.2 apply.
N/A
2.10.5.13
Requirements according to this annex, 6.1.2.1 and
6.1.2.2 apply.
N/A
5.1.7.1
Touch current measurement results exceeding 3,5
mA r.m.s are permitted only for the following
equipment:
- Stationary pluggable equipment Type A that: (1)
is intended to be used in a Restricted Access
Location where equipotential bonding has been
applied, for example, in a telecommunication
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 11 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
centre; and (2) has provision for a permanently
connected protective earthing conductor; and (3) is
provided with instructions for the installation of that
conductor by a service person;
- Stationary pluggable equipment Type B
- Stationary permanently connected equipment
6.1.2.1
"Add the following text between the first and
second paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least consist
of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that CLEARANCES
and CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below and
in addition
- passes the tests and inspection criteria of 2.10.11
with an electric strength test of 1,5 kV multiplied by
1,6 (the electric strength test of 2.10.10 shall be
performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test voltage
of 1,5 kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to EN
132400:1994, may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
132400, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in EN
60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all the
test specimens as described in EN 132400;
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400, in the
sequence of tests as described in EN 132400."
TRF No. IECEN60950_1C
UL International Demko A/S
N/A
Issue Date:
2011-01-12
Page 12 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
6.1.2.2
The exclusions are applicable for permanently
connected equipment and pluggable equipment
type B and equipment intended to be used in a
restricted access location where equipotential
bonding has been applied, e.g. in a
telecommunication centre, and which has provision
for a permanently connected protective earthing
conductor and is provided with instructions for the
installation of that conductor by a service person.
N/A
7.2
Requirements according to this annex, 6.1.2.1 and
6.1.2.2 apply with the term telecommunication
network in 6.1.2 being replaced by the term cable
distribution system.
N/A
7.3
There are many buildings where the screen of the
coaxial cable is not normally connected to the earth
in the building installation
N/A
Switzerland - Differences to IEC 60950-1:2005, Second Edition
1.5.1
Add NOTE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
N/A
1.7.13
Annex 2.15 of SR 814.81 applies for batteries
N/A
3.2.1.1
Supply cords of equipment having a rated current
not exceeding 10 A shall be provided with a plug
complying with SEV 1011 or IEC 60884-1 and one
of the following dimension sheets:
N/A
SEV 6532-2.1991, Plug type 15, 3P+N+PE
250/400 V,10 A
SEV 6533-2.1991, Plug type 11, L+N
250
V,10 A
SEV 6534-2.1991, Plug type 12, L+N+PE 250
V,10 A
In general, EN 60309 applies for plugs for currents
exceeding 10 A. However, a 16 A plug and socketoutlet system is being introduced in Switzerland,
the plugs of which are according to the following
dimension sheets, published in February 1998:
SEV 5932-2.1998, Plug type 25, 3P+N+PE
230/400 V,16 A
SEV 5933-2.1998, Plug type 21, L+N
250
V,16 A
SEV 5934-2.1998, Plug type 23, L+N+PE 250
V,16 A
3.2.4
Requirements according to this annex, 3.2.1.1
TRF No. IECEN60950_1C
UL International Demko A/S
N/A
Issue Date:
2011-01-12
Page 13 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
apply
USA / Canada - Differences to IEC 60950-1:2005, Second Edition
1.1
Equipment able to be installed in accordance with
the National Electrical Code ANSI/NFPA 70 and
the Canadian Electrical Code, Part1, and when
applicable, the National Electrical Safety Code,
IEEE C2.
Pass
1.1.1
Equipment able to be installed in accordance with
ANSI/NFPA 75 and NEC Art. 645 unless intended
for use outside of computer room and provided with
such instructions.
Pass
1.1.2
Equipment in wire-line communication facilities
serving high-voltage electric power stations
operating at greater than 1kV are excluded.
N/A
1.1.2
Special requirements apply to equipment intended
for use outdoors.
N/A
1.4.14
For Pluggable Equipment Type A, the protection in
the installation is assumed to be 20 A.
N/A
1.5.1
All IEC standards for components identified in
Annex P.1 replaced by the relevant requirements of
CSA and UL component standards in Annex P.1.
Pass
1.5.1
All IEC standards for components identified in
Annex P.2 alternatively satisfied by the relevant
requirements of CSA and UL component standards
in Annex P.2.
Pass
1.5.5
Interconnecting cables acceptable for the
application regarding voltage, current, temperature,
flammability, mechanical serviceability and the like.
Pass
1.5.5
For other than limited power and TNV circuits, the
type of output circuit identified for output connector.
N/A
1.5.5
External cable assemblies that exceed 3.05 m in
length to be types specified in the NEC and CEC.
No external interconnecting
flexible.
N/A
1.5.5
Detachable external interconnecting cables 3.05 m No external interconnecting
or less in length and provided with equipment
flexible.
marked to identify the responsible organization and
the designation for the cable.
N/A
1.5.5
Building wiring and cable for use in ducts, plenums
and other air handling space subject to special
requirements and excluded from scope.
N/A
1.5.5
Telephone line and extension cords and the like
comply with UL 1863 and CSA C22.2 No. 233.
N/A
1.6.1.2
Equipment intended for connection to a d.c. power
(mains) distribution system is subject to special
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 14 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
circuit classification requirements (e.g., TNV-2)
1.6.1.2
Earthing of d.c. powered equipment provided.
N/A
1.7
Lamp replacement information indicated on
lampholder in operator access area.
N/A
1.7.1
Special marking format for equipment intended for
use on a supply system with an earthed neutral
and more than one phase conductor.
N/A
1.7.1
Equipment voltage rating not higher than rating of
the plug except under special conditions.
N/A
1.7.6
Special fuse replacement marking for operator
accessible fuses.
N/A
1.7.7
Identification of terminal connection of the
equipment earthing conductor.
N/A
1.7.7
Connectors and field wiring terminals for external
Class 2 or Class 3 circuits provided with marking
indicating minimum Class of wiring to be used.
N/A
1.7.7
Marking located adjacent to terminals and visible
during wiring.
N/A
2.1.1.1
Bare TNV conductive parts in the interior of
equipment normally protected against contact by a
cover intended for occasional removal are exempt
provided instructions include directions for
disconnection of TNV prior to removal of the cover.
N/A
2.3.1.b
Other telecommunication signaling systems (e.g.,
message waiting) than described in 2.3.1(b) are
subject to M.4.
N/A
2.3.1.b
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding 42.4
Vp or 60 V d.c., the maximum current limit through
a 2000 Ohm or greater resistor with loads
disconnected is 7.1 mA peak or 30 mA d.c. under
normal conditions.
N/A
2.3.1.b
Limits for measurements across 5000 ohm resistor
in the event of a single fault are replaced after 200
ms with the limits of M.3.1.4.
N/A
2.3.2.1
In the event of a single fault, the limits of 2.2.3
apply to SELV circuits and accessible conductive
parts.
N/A
2.3.2.4
Enamel coating on signal transformer winding wire
allowed as an alternative to Basic insulation in
specific telecommunication applications when
subjected to special construction requirements and
routine testing.
N/A
2.5
Overcurrent protection device required for Class 2
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 15 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
and Class 3 limiting in accordance with the NEC, or
for a Limited Power Source, not interchangeable
with devices of higher ratings if operator
replaceable.
2.6
Equipment having receptacles for output a.c. power
connectors generated from an internal separately
derived source have the earthed (grounded) circuit
conductor suitably bonded to earth.
N/A
2.6.3.3
For Pluggable Equipment Type A, if a) b) or c) are
not applicable, the current rating of the circuit is
taken as 20 A
N/A
2.6.3.4
Capacity of connection between earthing terminal
and parts required to be earthed subject to special
conditions based on the current rating of the circuit.
N/A
2.6.3.4
Protective bonding conductors and their terminals
of non-standard constructions (e.g. PWB traces)
evaluated to limited short-circuit test of CSA C22.2
No.0.4.
N/A
2.6.4.1
Field wiring terminals for earthing conductors
suitable for wire sizes (gauge) used in US and
Canada.
N/A
2.7.1
Data for selection of special external branch circuit
overcurrent devices marked on the equipment.
N/A
2.7.1
Standard supply outlets protected by overcurrent
device in accordance with the NEC, and CEC, Part
1.
N/A
2.7.1
Overcurrent protection for individual transformers
that distribute power to other units over branch
circuit wiring.
N/A
2.7.1
Additional requirements for overcurrent protection
apply to equipment provided with panelboards.
N/A
2.7.1
Non-motor-operated equipment requiring special
overcurrent protective device marked with device
rating.
N/A
2.10.5.12
Multi-layer winding wire subject to UL component
wire requirements in addition to 2.10.5.12 and
Annex U.
N/A
3.1.1
Permissible combinations of internal wiring/external
cable sizes for overcurrent and short circuit
protection.
N/A
3.1.1
All interconnecting cables protected against
overcurrent and short circuit.
3.2
Wiring methods permit connection of equipment to
primary power supply in accordance with the NEC
TRF No. IECEN60950_1C
Interconnecting cables comply
with the relevant requirements
of this standard.
UL International Demko A/S
Pass
N/A
Issue Date:
2011-01-12
Page 16 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
and CEC, Part 1.
3.2.1
Permitted use for flexible cords and plugs.
N/A
3.2.1
Flexible cords provided with attachment plug rated
125% of equipment current rating.
N/A
3.2.1
Any Class II equipment provided with 15 or 20 A
standard supply outlets, Edison-base lampholders
or single pole disconnect device provided with a
polarized type attachment plug.
N/A
3.2.1.2
Equipment intended for connection to DC mains
supply power systems complies with special wiring
requirements (e.g., no permanent connection to
supply by flexible cord).
N/A
3.2.1.2
Equipment with one pole of the DC mains supply
connected to both the equipment mains input
terminal and the main protective earthing terminal
provided with special instructions and construction
provisions for earthing
N/A
3.2.1.2
Equipment with means for connecting supply to
earthing electrode conductor has no switches or
protective devices between supply connection and
earthing electrode connection.
N/A
3.2.1.2
Special markings and instructions for equipment
with provisions to connect earthed conductor of a
DC supply circuit to earthing conductor at the
equipment.
N/A
3.2.1.2
Special markings and instructions for equipment
with earthed conductor of a DC supply circuit
connected to the earthing conductor at the
equipment.
N/A
3.2.1.2
Terminals and leads provided for permanent
connection of DC powered equipment to supply
marked to indicate polarity if reverse polarity may
result in a hazard.
N/A
3.2.3
Permanently connected equipment has provision
for connecting and securing a field wiring system
(i.e. conduit, or leads etc.) per the NEC and CEC,
Part 1.
N/A
3.2.3
Permanently connected equipment may have
terminals or leads not smaller than No. 18 AWG
(0.82 mm2) and not less than 150 mm in length for
connection of field installed wiring.
N/A
3.2.3
If supply wires exceed 60 ¢XC, marking indicates
use of 75 ¢XC or 90 ¢XC wiring for supply
connection as appropriate.
N/A
3.2.3
Equipment compatible with suitable trade sizes of
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 17 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
conduits and cables.
3.2.5
Length of power supply cord limited to between 1.5
and 4.5 m unless shorter length used when
intended for a special installation.
N/A
3.2.5
Conductors in power supply cords sized according
to NEC and CEC, Part I.
N/A
3.2.5
Power supply cords and cord sets incorporate
flexible cords suitable for the particular application.
N/A
3.2.6
Strain relief provided for non-detachable
interconnecting cables not supplied by a limited
power source.
N/A
3.2.9
Adequate wire bending space and volume of field
wiring compartment required to properly make the
field connections.
N/A
3.2.9
Equipment intended solely for installation in
Restricted Access Locations using low voltage d.c.
systems may not need provision for connecting and
securing a field wiring system. A method of
securing wiring or instructions provided to ensure
the wiring is protected from abuse.
N/A
3.3
Field wiring terminals provided for interconnection
of units for other then LPS or Class 2 circuits also
comply with 3.3.
N/A
3.3
Interconnection of units by LPS or Class 2
conductors may have field wiring connectors other
than those specified in 3.3 if wiring is reliably
separated.
N/A
3.3.1
Terminals for the connection of neutral conductor
identified by a distinctive white marking or other
equally effective means.
N/A
3.3.3
Wire binding screw terminal permitted for
connection of No. 10 AWG (5.3 mm2) or smaller
conductor if provided with upturned lugs, cupped
washer or equivalent retention.
N/A
3.3.4
Terminals accept wire sizes (gauge) used in the
U.S. and Canada.
N/A
3.3.4
Terminals accept current-carrying conductors rated
125% of the equipment current rating.
N/A
3.3.6
Field wiring terminals marked to indicate the
material(s) of the conductor appropriate for the
terminals used.
N/A
3.3.6
Connection of an aluminum conductor not
permitted to terminal for equipment earthing
conductor.
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 18 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
3.3.6
Field wiring connections made through the use of
suitable pressure connectors (including set screw
type), solder lugs or splices to flexible leads.
N/A
3.4.2
Separate motor control device(s) required for cordconnected equipment rated more than 12 A, or with
motor rated more than 1/3 hp or more than 120 V.
N/A
3.4.8
Vertically mounted disconnect devices oriented so
up position of handle is "on".
N/A
3.4.11
For computer-room applications, equipment with
battery systems capable of supplying 750 VA for 5
min require battery disconnect means.
N/A
4.2.8.1
Special opening restrictions for enclosures around
CRTs with face dimension of 160 mm or more.
4.2.9
Compartment housing high-pressure lamp marked
to indicate risk of explosion.
N/A
4.2.11
For equipment intended for mounting on racks and
provided with slide/rails allowing the equipment to
slide away from the rack for installation, service
and maintenance, additional construction,
performance and marking requirements are
applicable to determine the adequacy of the
slide/rails.
N/A
4.3.2
Loading test for equipment with handle(s) used to
support more than 9 kg tested at four times the
weight of the unit.
N/A
4.3.6
In addition to the IEC requirements, Direct Plug-in
Equipment complies with UL 1310 or CSA 223
mechanical assembly requirements.
N/A
4.3.12
The maximum quantity of flammable liquid stored
in equipment complies with ANSI/NFPA 30(Table
NAE.6).
N/A
4.3.12
Equipment using replenishable liquids marked to
indicate type of liquid to be used.
No flammable liquids within the
equipment.
N/A
4.3.13.2
Equipment that produces x-radiation and does not No flammable liquids within the
comply with 4.3.12 under all conditions of servicing equipment.
marked to indicate the presence of radiation where
readily visible.
N/A
4.3.13.5
Requirements contained in the applicable national
codes and regulations apply to lasers (21 CFR
1040 and REDR C1370).
N/A
4.7
Automated information storage equipment intended
to contain more than 0.76 m3 of combustible media
requires provision for automatic sprinklers or a
gaseous agent extinguishing system.
N/A
4.7.3.1
Equipment for use in environmental air space other
N/A
TRF No. IECEN60950_1C
Result - Remark
No CRT.
UL International Demko A/S
Verdict
N/A
Issue Date:
2011-01-12
Page 19 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
than ducts or plenums provided with metal
enclosure or with non-metallic enclosure having
adequate fire-resistance and low smoke producing
characteristics. Low smoke-producing
characteristics evaluated according to UL 2043.
Equipment for installation in space used for
environmental air as described in Sec. 300-22(c) of
the NEC provided with instructions indicating
suitability for installation in such locations.
4.7.3.1
Flame spread rating for external surface of
combustible material with exposed area greater
than 0.93 m2 or a single dimension greater than
1.8 m; 50 or less for computer room applications or
200 or less for other applications.
The equipment has no
combustible material greater
than 0.9m2 or single
dimension greater than 1.8m
N/A
4.7.3.4
Wire marked "VW-1" or "FT-1" considered
equivalent.
Internal wiring is UL
Recognized, marked VW-1 or
FT-1 and strapped by
individual cable ties.
Pass
5.1.8.2
Special earthing provisions and instructions for
equipment with high touch current due to
telecommunication network connections.
N/A
5.1.8.3
Touch current due to ringing voltage for equipment
containing telecommunication network leads.
N/A
5.3.7
Overloading of SELV connectors and printed wiring (See appended table 2.5)
board receptacles accessible to the operator.
Pass
5.3.7
Tests interrupted by opening of a component
repeated two additional times.
N/A
5.3.9.1
Test interrupted by opening of wire or trace subject
to certain conditions.
N/A
6
Specialized instructions provided for telephones
that may be connected to a telecommunications
network.
Pass
6
Marking identifying function of telecommunication
type connectors not used for connection to a
telecommunication network.
Pass
6.3
Equipment remotely powered over
telecommunication wiring systems provided with
specialized markings adjacent to the connection.
N/A
6.3
Overcurrent protection incorporated into equipment
to provide power over telecommunication wiring
system not interchangeable with devices of higher
ratings if operator replaceable.
N/A
6.4
Additional requirements for equipment intended for
connection to a telecommunication network using
cable subject to overvoltage from power line
failures (Fig. 6C).
Pass
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 20 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
6.4
Where 26 AWG line cord required by Fig. 6C,
either the cord is provided with the equipment or
described in the safety instructions.
N/A
7
Equipment associated with the cable distribution
system may need to be subjected to applicable
parts of Chapter 8 of the NEC.
N/A
H
Ionizing radiation measurements made under
single fault conditions in accordance with the
requirements of the Code of Federal Regulations
21 CFR 1020 and the Canadian Radiation Emitting
Devices Act, REDR C1370.
N/A
M.2
Continuous ringing signals evaluated to Method A
subjected to special accessibility considerations.
N/A
M.4
Special requirements for message waiting and
similar telecommunications signals.
N/A
NAC
Equipment intended for use with a generic
secondary protector marked with suitable
instructions.
N/A
NAC
Equipment intended for use with a specific primary
or secondary protector marked with suitable
instructions.
N/A
NAD
Acoustic pressure from an ear piece less than 136
dBA for short duration disturbances, and less than
125 dBA for handsets, 118 dBA for headsets, and
121 dBA for insert earphones, for long duration
disturbances.
N/A
NAD
Equipment connected to a telecommunication and
cable distribution networks and supplied with an
earphone intended to be held against, or in the ear
is required to comply with special acoustic pressure
requirements.
N/A
NAF
Household/Home Office Document Shredders
N/A
NAF.1.7
Markings and instructions alert the user to key
safety considerations related to use of shredders,
including not intended to be used by children, avoid
touching document feed opening, avoid clothes
and hair entanglement, and avoid aerosol products.
N/A
NAF.2.8.3
Safety interlock cannot be inadvertently activated
by the articulated accessibility probe (figure
NAF.1).
N/A
NAF.3.4
Provided with an isolating switch complying with
3.4.2, including 3 mm contact gap, with appropriate
markings associated with the switch.
N/A
NAF.4.4
Hazardous moving parts are not accessible, as
determined using the articulated accessibility probe
N/A
TRF No. IECEN60950_1C
Result - Remark
UL International Demko A/S
Verdict
Issue Date:
2011-01-12
Page 21 of 21
Report Reference #
ASL10120310
IEC 60950-1 / EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
(figure NAF.1) and the accessibility probe/wedge
(figures NAF.2/NAF.3).
United Kingdom - Differences to IEC 60950-1:2005, Second Edition
2.6.3.3
The current rating of the circuit shall be taken as 13
A, not 16 A.
N/A
2.7.1
To protect against excessive currents and shortcircuits in the PRIMARY CIRCUIT of DIRECT
PLUG-IN EQUIPMENT, tests according to 5.3 shall
be conducted, using an external protective device
rated 30 A or 32 A. If these tests fail, suitable
protective devices shall be included as integral
parts of the DIRECT PLUG-IN EQUIPMENT, so
that the requirements of 5.3 are met.
N/A
3.2.1.1
Apparatus which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug, shall be fitted with a
"standard plug" in accordance with Statutory
Instrument 1786: 1994 - The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those regulations.
N/A
NOTE: "Standard plug" is defined in SI 1786: 1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
3.2.5.1
A power supply cord with conductor of 1.25 mm2 is
allowed for equipment with a rated current over
10A and up to and including 13A.
N/A
3.3.4
The range of conductor sizes of flexible cords to be The power cord is not provided
accepted by terminals for equipment with a rated
with the equipment.
current of over 10 A up to and including 13 A is
1.25 mm2 to 1.5 mm2 nominal cross-sectional
area.
N/A
4.3.6
The torque test is performed using a socket outlet
complying with BS 1363 part 1:1995, including
Amendment 1:1997 and Amendment 2:2003 and
the plug part of DIRECT PLUG-IN EQUIPMENT
shall be assessed to BS 1363: Part 1, 12.1, 12.2,
12.3, 12.9, 12.11, 12.12, 12.13, 12.16 and 12.17,
except that the test of 12.17 is performed at not
less than 125 oC. Where the metal earth pin is
replaced by an Insulated Shutter Opening Device
(ISOD), the requirements of clauses 22.2 and 23
also apply.
N/A
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 1 of 28
Report Reference #
ASL10120310
Enclosure
Photographs
Supplement Id
Description
3-01
Top view
3-02
Bottom view (1)
3-03
Bottom view (2)
3-04
Bottom view (with VGA)
3-05
Bottom view (without VGA)
3-06
Right side view
3-07
Left side view
3-08
Open view
3-09
Inside view
3-10
Top view for mother board type A15HC
3-11
Bottom view for mother board type A15HC
3-12
Top view for IO board type A15HC IO BOARD
3-13
Bottom view for IO board type A15HC IO BOARD
3-14
Battery pack top view for model A32-A15
3-15
Battery pack bottom view for model A32-A15
3-16
Battery pack cell type_ICR18650-22++ for model A32-A15
3-17
Battery pack Inside view for model A32-A15
3-18
Battery pack protection board top view for model A32-A15
3-19
Battery pack protection board bottom view for model A32-A15
3-20
Battery pack top view for model A42-A15
3-21
Battery pack bottom view for model A42-A15
3-22
Battery pack cell type_ICR18650-22++ for model A42-A15
3-23
Battery pack cell type_ICR18650B3 for model A42-A15
3-24
Battery pack Inside view for model A42-A15 (with cell type_ ICR18650-22++)
3-25
Battery pack Inside view for model A42-A15 (with cell type_ ICR18650B3)
3-26
Battery pack protection board top view for model A42-A15
3-27
Battery pack protection board bottom view for model A42-A15
TRF No. IECEN60950_1C
UL International Demko A/S
Issue Date:
2011-01-12
Page 2 of 28
Report Reference #
Photographs ID 3-01
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 3 of 28
Report Reference #
Photographs ID 3-02
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 4 of 28
Report Reference #
Photographs ID 3-03
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 5 of 28
Report Reference #
Photographs ID 3-04
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 6 of 28
Report Reference #
Photographs ID 3-05
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 7 of 28
Report Reference #
Photographs ID 3-06
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 8 of 28
Report Reference #
Photographs ID 3-07
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 9 of 28
Report Reference #
Photographs ID 3-08
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 10 of 28
Report Reference #
Photographs ID 3-09
(With VGA)
(Without VGA)
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 11 of 28
Report Reference #
Photographs ID 3-10
(With VGA)
(Without VGA)
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 12 of 28
Report Reference #
Photographs ID 3-11
(With VGA)
(Without VGA)
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 13 of 28
Report Reference #
Photographs ID 3-12
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 14 of 28
Report Reference #
Photographs ID 3-13
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 15 of 28
Report Reference #
Photographs ID 3-14
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 16 of 28
Report Reference #
Photographs ID 3-15
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 17 of 28
Report Reference #
Photographs ID 3-16
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 18 of 28
Report Reference #
Photographs ID 3-17
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 19 of 28
Report Reference #
Photographs ID 3-18
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 20 of 28
Report Reference #
Photographs ID 3-19
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 21 of 28
Report Reference #
Photographs ID 3-20
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 22 of 28
Report Reference #
Photographs ID 3-21
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 23 of 28
Report Reference #
Photographs ID 3-22
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 24 of 28
Report Reference #
Photographs ID 3-23
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 25 of 28
Report Reference #
Photographs ID 3-24
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 26 of 28
Report Reference #
Photographs ID 3-25
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 27 of 28
Report Reference #
Photographs ID 3-26
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 28 of 28
Report Reference #
Photographs ID 3-27
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 1 of 5
Report Reference #
Enclosure
Schematics + PWB
Supplement Id
Description
5-01
RTC Battery Protection Circuit for M/B model: A15HC
5-02
USB Protection Circuit for M/B model: A15HC
5-03
HDMI Protection Circuit for M/B model: A15HC
5-04
USB Protection Circuit for I/O Board model: A15HC IO BOARD
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 2 of 5
Report Reference #
Schematics + PWB ID 5-01
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 3 of 5
Report Reference #
Schematics + PWB ID 5-02
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 4 of 5
Report Reference #
Schematics + PWB ID 5-03
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 5 of 5
Report Reference #
Schematics + PWB ID 5-04
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 1 of 3
Report Reference #
Enclosure
Manuals
Supplement Id
6-01
Description
Safety Instruction written in manual
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 2 of 3
Report Reference #
Manuals ID 6-01
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 3 of 3
Report Reference #
Manuals ID 6-01
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 1 of 7
Report Reference #
Enclosure
Miscellaneous
Supplement Id
Description
7-01
Test table
7-02
Enclosure drawing
7-03
Bottom Opening dimension
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 2 of 7
Report Reference #
ASL10120310
Miscellaneous ID 7-01
Table 2.1.1.5
Energy Hazard Measurements
Accessible Parts
N/A
Maximum
VA
Test Points From / To
Maximum
V (Volts)
Maximum
A (Amps)
Note(s):
Table 2.1.1.7
Capacitance Discharge Test
Fuse
In/Out
Measurement Locations
N/A
Switch
Position
37% Vo
(V pk)
Vo (V pk)
Vtc (V pk)
Note(s):
Table 2.2
SELV Reliability Test
N/A
Hazardous Voltage (Circuit) Measurement
Clearance and creepage distance at/of:
No.
Accessible Part
From - To
Component
No.
(Voltage
Limiting)
Fault
Up
(V)
Test
Voltage
U r.m.s.
(V)
Test time
(Duration)
Limiting component
Fuse
No.
Fuse
Current
(A)
Result
Specify
Maximum
Vpk or
V dc
Note(s):
Table 2.4.2
Limited Current Circuit Measurements
Fault
Volts Peak
Volts dc
N/A
mAp
Result Part I
TRF No. IECEN60950_1C
UL International Demko A/S
mA dc
Frequency
kHz
Issue Date:
2011-01-12
Page 3 of 7
Report Reference #
ASL10120310
User Accessible Live Part: __________ to Pole 1: __________
User Accessible Live Part: __________ to Pole 2: __________
User Accessible Live Part: __________ to Earth
Note(s):
Result Part II
Location
User Part
Fault
To
Voltage
μF
μC
mJ
Note(s):
Table 2.5
Limited Power Source Measurements
Measured
Output Tested
MB: PEGATRON
/A15HC, IO BOARD:
PEGATRON /A15HC
IO BOARD
USB1 (J6906)
(F6901)
USB1 (J6906)
USB2 (J6904)
(F6901)
USB2 (J6904)
USB3 (J5207)
(U5202)
USB3 (J5207)
USB4 (J5202)
(U5201)
Pass
From
To
Single
Fault
Condition
--
--
--
--
--
Pin1
GND
Normal
5.07
3.0
Pin2-4
GND
Normal
0
0
Pin1
GND
Normal
5.07
3.0
Pin2-4
GND
Normal
0
0
Pin1
GND
Normal
5.07
2.4
Pin2-9
GND
Normal
0
0
Pin1
GND
Normal
5.07
2.3
TRF No. IECEN60950_1C
Uoc
UL International Demko A/S
Maximum
Isc 5
VA 5 s
s
-10.41
(3.0Ax3.47V)
0
10.41
(3.0Ax3.47V)
0
10.28
(2.4Ax4.28V)
0
9.94
(2.3Ax4.32V)
Issue Date:
2011-01-12
USB4 (J5202)
HDMI (J4801)
(F4801)
HDMI (J4801)
HDMI (J4801)
VGA (J4601)
VGA (J4601)
VGA (J4601)
RJ45 (J3401)
AUDIO1 (J6901)
AUDIO2 (J6902)
Card reader (J4001)
(U4001)
Card reader (J4001)
(U4001)
Card reader (J4001)
Page 4 of 7
Report Reference #
ASL10120310
Pin2-9
GND
Normal
0
0
Pin18
GND
Normal
5.06
0.5
Pin15,16
Pin1-14,17,19
Pin12,15
Pin13,14
Pin1-11
Pin1-8
Pin1-5
Pin1-5
GND
GND
GND
GND
GND
GND
GND
GND
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
4.75
0
4.52
3.27
0
0
0
0
0
0
0
0
0
0
0
0
Pin4,11
GND
Normal
3.30
0.5
Pin4,11
GND
U4001 (910) short
3.32
7.8
Pin1-3,5-10,1222
GND
Normal
0
0
0
2.08
(0.5Ax4.15V)
0
0
0
0
0
0
0
0
1.13
(0.5Ax2.26V)
9.32
(5.9Ax1.58V)
0
Note(s):
MB: PEGATRON /A15HC, IO BOARD: PEGATRON /A15HC IO BOARD
PTC for J6906,J6904 by F6901 rating: 6V/1.5A
PTC for J4801 by F4801 rating: 6V/0.35A
Table 2.6.3.4
Earthing Test
Accessible Conductive Part
N/A
Current
(Amps)
Voltage Drop
(Volts)
Resistance
(Ù)
Note(s):
Table 2.10.2
Working Voltage Measurement Test
Clearance and creepage distance dcr at/of:
N/A
Up (V)
U r.m.s. (V)
Note(s):
Table 5.1.6
Touch Current Test
TRF No. IECEN60950_1C
N/A
UL International Demko A/S
Issue Date:
Terminal A
(Switch
“s”) of
Measuring
Instrument
Connected
to:
2011-01-12
Page 5 of 7
Report Reference #
ASL10120310
Touch Current (mA r.m.s.)
Polarity P1/Primary Switch Condition
Switch
“e”
Position
Test voltage
Normal/On
Normal/Off
Note(s):
TRF No. IECEN60950_1C
UL International Demko A/S
Reverse/On
Reverse/Off
Issue Date:
2011-01-12
Page 6 of 7
Report Reference #
Miscellaneous ID 7-02
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310
Issue Date:
2011-01-12
Page 7 of 7
Report Reference #
Miscellaneous ID 7-03
TRF No. IECEN60950_1C
UL International Demko A/S
ASL10120310