MX48_Literature
MX 48
8 Channel Controller
•
•
•
•
Easy operation
Up to 8 channels
Programming by keypad or PC
Serial/analog outputs
T
he MX 48 is designed to protect your property
and personnel in environments likely to contain
flammable or toxic gases.
Equipped with up to 8 independent channels, the
MX 48 can be used to control different types of
detectors. In fact, this unit is compatible with all the
detector-transmitters in the Industrial Scientific range
and any detector with a standard 4-20 mA output.
www.indsci.com
MX 48
Designed To Meet Your Needs
The MX 48 caters to a wide range of possible
uses, adapting to your safety requirements.
The variety of programming options, by keypad
or computer, ensures it meets specific user
needs. Furthermore, the MX 48 is open-ended,
so that if required, subsequent extensions or
modifications can be added.
Easy to install and very flexible to use, the
MX 48 can handle multiple applications to
accommodate your technical requirements at
lower costs.
Measurement and alarm unit
The MX 48 is designed for prevention, action
and detection. The controller:
• monitors sensors and detectors
• displays the nature, concentration, measurement
and unit of the gas detected (in cyclic mode)
• triggers alarms if the measurement exceeds
thresholds
• actuates relays for the control of warning devices,
valves and mimic panels
• indicates faults
• transmits data via analog and serial outputs
• has enhanced European standards EN 50054,
50081, 50082 and low voltage directives
Series
Enhanced Ergonomics and Performance
User-friendly display panel
Fixed or scrolling LCD
display on two lines of 16
characters
5 indicator lights per channel:
• on/off
• AL1
• AL2
• AL3
• Fault
4-button keypad
Triple alarm level
• 3 individually adjustable alarm levels
• Alarms 1 and 2 are instantaneous
• Alarm 3 time-delayed or based on average rate
• Local or remote acknowledgement
Simple operation
• 4-20 mA input so that any type of standard detector
can be connected
• Common serial output in Modbus (J-BUS) format
• Analog outputs-one per channel
• Management of faults and alarms by
micro-controller
s 60
High reliability
• Fault monitoring
• Alarm activation
• Internal testing of LED's and display
• Transmission of measurements, alarms, failures and
relay status via RS232 or 485
• Programmable relays-ND or NC for fail safe
operation
• Maintenance bypass mode indicated by an LED
Safe and secure unit
• Protection against radio frequencies and industrial
interference, to avoid false alarms in environments
subject to electrical interference (EMC compliance)
• Integrated protection against human operating
errors
• Protected access to programming
MX 48
SPECIFICATIONS
Loop Impedance:
Flammable, 3 wires - 32 Ω
Type:
Wall mounted controller
Function:
Microcontroller-based multichannel monitor
4-20 mA : 2 or 3 wires - 56 Ω
Capacity:
Up to 8 channels
Display:
Fluorescent, 2 lines of 16 characters
Average line length (in meters at 20°C for a 1,5
mm2 conductor)
Flammable : 1,000 m/ 4-20 mA 2,000 m
Fixed or scrolling
ALARMS:
Fault alarm:
Yellow LED on each channel
Signal output:
Action on common relay
Gas alarm:
3 independent thresholds
per channel (Red LED’s)
Serial RS 485 or 232 in Modbus (J-BUS)
format, opto-insulation an option
Power supply:
3rd threshold time-delayed
or mean value
Audio Alarm:
80 db at 30 cm
Relay output:
2 gas alarm relays per channel
Power consumption : 200 VA or 150 W
Miscellaneous:
Positive safety on failure
Programmable NO or -NC
Acknowledgement : local or remote
Operating temperature : -20°C to +55°C
Relative humidity 5% to 95%,
uncondensed
Compliant with European
Standards 50054, 50081 and 50082
1 relay common for alarm 3
Programmable positive
or negative safety on alarm relay
109 to 122 V AC or 207 to 277 V AC
21 to 31 V DC
Manual or automatic reset
2 relay outputs per channel
common relay on alarm 3
Analog 4-20 mA per channel,
load resistance : 600 Ω max.
Protection:
IP 65
Weight:
11 Kg
Dimensions:
H 340 x W 500 x D 89 mm
MEASUREMENT INPUT :
Type of Detectors:
Flammable Bridge Type
80,5
500
Flammable transmitter, toxic or
oxygen detector, (type 4-20 mA)
Link:
2 or 3 wires
340
340
89
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement