Data sheet CONNECTsystem for monochrome LED flex modules with 10 mm width ( LM10P, LM10L, LM10A, LM11A)

Data sheet CONNECTsystem for monochrome LED flex modules with 10 mm width ( LM10P, LM10L, LM10A, LM11A)
Data Sheet
CONNECTsystem for LINEARlight Flex
LM-xx Flex
Benefits
¾
Universal feeder and connector for all
LINEARlight Flex modules
¾
Assembly without tools
¾
Reduced assembly work schedule
¾
Highly shock resistant
Applications
¾
Connect system for LINEARlight Flex
modules, LINEARlight POWER Flex,
LINEARlight Colormix Flex
Technical Operating Data and Ordering Guide
Product
EAN *
S-Unit *
Max Voltage
[V]
Max Current
[A]
LM-2PIN Flex
4008321916211
100
25
2,1
LM-4PIN Flex
4008321916235
100
25
LM-CONN-10 Flex
4008321916259
200
25
LM-CONN-150 Flex
4008321931375
200
25
Diameter of Wire
[mm² / AWG]
Length of Wire
[mm]
0,14 / 26
500
2,1
0,14 / 26
500
2,1
0,057 / 30
10
2,1
0,057 / 30
150
*) EAN: Bag containing 10 pieces
S-Unit: Modules per shipping unit
Technical Features
¾ Feeder LM-2PIN Flex for connection of all
LINEARlight Flex and LINEARlight POWER Flex
with power supply
¾ Allowed operating temperature suited to all
LINEARlight Flex products
¾ Contact possible at the gable-end or at the
¾ Feeder LM-4PIN Flex for connection of
LINEARlight Colormix Flex with power supply.
Wires are color-coded
¾ Board to board connection of two Flex modules:
LM-CONN-10 Flex for short gaps,
LM-CONN-150 Flex for longer gaps
LM-xx Flex - 01.01.2009
splitting point
¾ Locker granting shock and vibration proofness
according to IEC 60512
¾ Use only in indoor applications or in luminaires
with IP67 rating
Page 1 of 3
Drawings
LM-2PIN Flex
Housing
PPS / Polyamide / black
Isolation of Wires
PVC / black/red
Housing
PPS / Polyamide / black
Isolation of Wires
PVC / black/blue/green/red
Housing
PPS / Polyamide / black
Isolation of Wires
Aramid Paper / white
Housing
PPS / Polyamide / black
Isolation of Wires
Aramid Paper / white
LM-4PIN Flex
LM-CONN-10 Flex
LM-CONN-150 Flex
LM-xx Flex - 01.01.2009
Page 2 of 3
Safety Information
¾ All components of the CONNECTsystem Flex must be assembled to avoid any stress on the wires and/or board connectors. The
installer must ensure that there is adequate strain relief between the board connection and the wiring.
¾ In order to maintain adequate electrical contact, please refrain from repeat removal, maximum of 5, of the CONNECTsystem Flex.
¾ Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards.
Only qualified personnel should be allowed to perform installations.
¾ The connector has no inverse polarity protection. There will be no electrical function if connector is not well positioned or if polarity
is inverse. Several modules can be damaged (see the respective module data sheet).
¾ The maximum operation current on page 1 may not be exceeded.
¾ For LM-4PIN Flex the maximum allowed current per cable is:
- red, green, blue: 1A
- black: 2,1A
¾ The CONNECTsystem Flex is designed for indoor application only. Any unprotected outdoor use is not allowed.
¾ A suitable enclosure IP67 is required if the system is to be exposed to humidity and /or dust. Condensation water in the IP67
enclosure is not allowed.
Assembly Information
¾ For electrical connection of the LINEARlight Flex modules open the locker by pulling and place the module in the slot. The "up"
mark of the CONNECTsystem Flex must face towards to front side of the LED module for an electrical connection between the
solder pads and the CONNECTsystem Flex. The CONNECTsystem Flex is locked by pushing the slot back.
¾ Pay attention to the correct polarity between feeder LM-xPIN Flex and LED module:
- For the feeder LM-2PIN Flex connect the black cable to the '-' pole and the red cable to the '+' pole of the module
- For the feeder LM-4PIN Flex connect the black cable to the '+' pole of the module and the red, green and blue cable to the R-, G-,
B-poles (see fotos on page 2)
¾ Particular attention is required when using the connector for board to board connection: The '+' pole of the first module has to be
connected to the '+' pole of the second module. In case of wrong polarity no light will be emitted and the moules can be damaged
(see the respective module data sheet).
Sales and Technical Support
OSRAM GmbH
Hellabrunner Strasse 1
D - 81536 München
Germany
www.osram.com
+49 (0)89 6213-0
Sales and technical support is given by the
local OSRAM subsidiaries.
On our world wide homepage all OSRAM
subsidiaries are listed with complete
address and phone numbers.
Related and Further Information
¾ The new dimension of light
¾ Datasheets LINEARlight Flex (LM10A, LM11A),
LINEARlight POWER Flex (LM10P), LINEARlight
Colormix Flex (LM10L)
¾ OSRAM LED systems
¾ New standards for LED control gear
LM-xx Flex - 01.01.2009
153 S006 GB
www.osram.com/led-systems-downloads
www.osram.com/led-systems-downloads
www.osram.com/led-systems
130 W011 GB
www.osram.com/ecg-download
Page 3 of 3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement