Расходные материалы для жидкостной хроматографии

Расходные материалы для жидкостной хроматографии
HPLC
Accessories
HPLC Accessories
Instrument Replacement Parts . . . . . . . . . . . . . . . . . . .342-347
Filters, Mobile Phase Accessories . . . . . . . . . . . . . . . . .348-353
Fittings, Connectors, Tools, Tubing . . . . . . . . . . . . . . .354-358
Flow Splitters, Static Mixers, Backpressure Regulators,
Pulse Dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .359-360
Column Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .361
Column Pack in a Box Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . .362
Organizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .362
Tech Tips: Pressure Conversion; Solvent Miscibility . . . .363
HPLC Syringes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .293-297
HPLC Column Test Mixes . . . . . . . . . . . . . . . . . . . . . . . . .516-517
Reference Books . . . . . . . . . . . . . . . . . . . . . . . .www.restek.com
HPLC Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .298-339
HPLC Applications . . . . . . . . . . . . . . . . . . . . . . . . . .518-559
342
Replacement Parts
H P LC ACC E S S O R I E S
Restek Replacement Parts for Agilent HPLC Systems
Piston Seals
Outlet Ball Valve
Needle Seat Assembly
new!
Lamp, VWD G1314A
new!
Description
Preventive Maintenance Kit (Includes: rotor seal,
needle seat, needle assembly, seat cap)
Autosampler Preventive Maintenance Kit (Includes:
rotor seal, needle assembly, needle seat)
Pump Maintenance Kit (Includes: PTFE frit, outlet cap,
active inlet cartridge, gold disk seal, 2 piston seals,
glass solvent filter)
Outlet Ball Valve, Binary Pump
Outlet Ball Valve
Sieves for Outlet Valve
Check Valve Cartridge Assembly
Piston Seals, Teflon® w/Graphite
Piston Seals, Teflon® w/Graphite
Piston Seals (Black)
Seal Wash Kit, Binary Pump (4 seals, 4 gaskets)
Seal Wash Kit (2 seals, 2 gaskets)
Wash Seal
Sapphire Piston
Sapphire Piston
Needle Seat
Needle Seat
Needle Seat Assembly
Needle Assembly
Rotor Seal (not for use with 7125 injection valve)
Rotor Seal
Rotor Seal (Rheodyne®-style)
Frits, PTFE
Seal, Gold Disk (outlet)
Outlet Cap
Outlet Cap & Gold Seal Assembly
Connecting Tube
Bottle Head Assembly
Detector Lamp, 1090 DA, 1050 VW/DA/MWD
Lamp, DAD G1315A, G1365A
Lamp, VWD G1314A
8453 Deuterium Lamp
G1321 Fluorescence Detector Flash Lamp
Lamp, DAD Long Life Deuterium (2000 hours)
Helium Tubing, 5m, PTFE, 0.057" ID
Injector Lubricant, PTFE, 10g
Model #
Similar to
Agilent part #
qty.
cat.#
1050
01078-68721
kit
25259
1100
G1313-68709
kit
25271
1050, 1100
1100, 1200
1050, 1100, 1200
1050, 1100, 1200
1090
1050, 1100, 1200
1050, 1100, 1200
1090
1100
1050, 1100
1050, 1100, 1200
1050, 1100, 1200
1090
1050
1090
1100
1100
1050
1100
1090
1050, 1100, 1200
1050, 1100, 1200
1050, 1100
1050, 1100
1050, 1100
—
1090, 1050
1100, 1200
1100, 1200
—
—
1100
1050, 1100
1050, 1100
G1311-68710
G1312-60012
G1311-60012
5063-6505
79835-67101
5063-6589
5063-6589
5062-2494
—
—
0905-1175
5063-6586
6980-0672
79846-67101
79846-67101
G1313-87101
G1313-87201
0101-0626
0100-1853
0101-0623
01018-22707
5001-3707
5062-2485
—
G1311-67304
G1311-60003
79883-60002
2140-0590
G1314-60100
2140-0605
2140-0600
5181-1530
5062-2461
79841-65501
kit
ea.
ea.
10-pk.
ea.
2-pk.
10-pk.
4-pk.
kit
kit
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
5-pk.
ea.
4-pk.
2-pk.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
25270
25267
25276
25266
25344
22482
22483
25347
25268
25269
25277
25273
25345
25258
25348
25265
25278
25272
25275
25349
25466
25467
25139
25140
25058
25059
25260
25261
25262
25263
25264
25399
24990
26520
qty.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
10-pk.
cat.#
26525
26526
26527
26528
26529
26530
26531
26532
26533
26534
26535
26536
26537
price
Capillary Stainless Steel Tubing Assemblies for Agilent HPLC Systems
Capillary SS Tubing
with fittings
Mixing Capillary Assembly
Description
Capillary SS Tubing, 130mm x 0.17mm ID, with fittings
Capillary SS Tubing, 800mm x 0.17mm ID, with fittings
Capillary SS Tubing, 180mm x 0.17mm ID, with fittings
Capillary SS Tubing, 700mm x 0.25mm ID, with fittings
Capillary SS Tubing, 700mm x 0.25mm ID, with fittings
Seat Capillary, SS Tubing, 0.17mm ID
Capillary SS Tubing, 105mm x 0.17mmID
Mixing Capillary Assembly
Capillary SS Tubing, Valve to Metering Head
Capillary SS Tubing, 150mm x 0.17mm ID
Capillary SS Tubing, 280mm x 0.17mm ID
Capillary SS Tubing, 400mm x 0.17mm ID
1
/16" SS Fitting, Front and Back Ferrules
Phone: 800-356-1688 or 814-353-1300
www.restek.com
Model #
1090
1050
1100
1050
1050
1050
—
1100
1100
—
—
—
—
Similar to
Agilent part #
01090-87305
01078-87305
G1313-87305
01018-67305
01078-87306
01078-87303
5021-1816
G1312-67302
G1313-87301
5021-1817
5021-1818
5021-1819
5062-2418
price
Replacement Parts
343
Outlet Cap and Gold Seal Assembly Tool for Agilent 1050 & 1100 HPLC Systems
Easily install the gold seal into the outlet cap.
Push the Assembly
Tool together.
Hold onto Outlet Cap
and pull Assembly
Tool apart.
Put Gold Seal over pin
on male part of
Assembly Tool.
Push the Assembly
Tool together and
press the Gold Seal in
the Outlet Cap.
Description
Outlet Cap and Gold Seal Assembly Tool for Agilent 1050 & 1100 HPLC Systems
Seal, Gold Disk (outlet)
Outlet Cap
Outlet Cap & Gold Seal Assembly
Pull the Assembly Tool
apart and remove
assembled Outlet Cap
and Gold Seal.
qty.
ea.
ea.
4-pk.
2-pk.
cat.#
24989
25467
25139
25140
price
Similar to
Beckman part #
qty.
cat.#
price
240720
ea.
25439
240721
ea.
25440
240620
ea.
25441
240621
243713
240619
243045
243053
887138
236797
ea.
ea.
ea.
ea.
ea.
ea.
ea.
25442
25444
25445
25446
25447
25448
25449
240714
241037
241037
728772
596791
ea.
ea.
ea.
ea.
ea.
25450
25451
25452
25453
25454
Similar to
Hitachi part #
AN0-085
AN0-0833
AN0-0834
810-1033
655-1080
655-1080
AN0-0836
AN0-0837
810-3085
AN0-0818
885-3570
qty.
2-pk.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
cat.#
25455
25456
25457
25458
25459
25460
25461
25462
25463
25464
25465
Outlet Cap & Gold Seal
Assembly
Restek Replacement Parts for Beckman HPLC Systems
Description
Inlet Check Valve Assembly
Outlet Check Valve Assembly
Inlet Check Valve Cartridge
for Check Valve Assembly
Outlet Check Valve Cartridge
for Check Valve Assembly
Guide Sleeve for Graphite Plunger Guide
Outlet Check Filter Frit Assembly
Piston Guide Assembly
Plunger
Plunger Seal
Plunger Seal
Sapphire Plunger
Plunger Seal
Pump Seal, Gold*
Plunger Wash Seal
Deuterium Lamp
Model #
110A&B, 112, 114M, 116, 118, 125,
126, 127, 128 Pumps
110A&B, 112, 114M, 116, 118, 125,
126, 127, 128 Pumps
110A&B, 112, 114M, 116, 118, 125,
126, 127, 128 Pumps
110A&B, 112, 114M, 116, 118, 125,
126, 127, 128 Pumps
110 Series Pumps
110 Series Pumps
110 Series and 112 Pumps
110 Series and 112 Pumps
110 Series Pumps
112 Pumps
114M, 116, 118, 125, 126, 127, 128
Pumps
114M, 116, 118, 126, 127, 128 Pumps
114, 116, 125, 126, 127, 128 Pumps
125, 126, 127, 128 Pumps
DU60, 62, 64, 65
Outlet Check Valve
Assembly
Sapphire Plunger
*Ultra-high molecular weight polyethylene (UHMWPE).
Restek Replacement Parts for Hitachi HPLC Systems
Description
SS Check Valve Cartridges (1/16" Ruby Ball)
Inlet Check Valve Assembly
Outlet Check Valve Assembly
Plunger Assembly
Plunger Seal
Plunger Seal, Gold
Inlet Check Valve Assembly
Outlet Check Valve Assembly
Rotor Assembly for Dilutor Valve
Rotor Seal Kit
Deuterium Lamp, Prealigned
Model #
655/6000/6200
655/6000/6200
655/6000/6200
655, 6000, 6200, 7100
L655A, 6000, 6200, 7100
655, 6000, 6200, 7100
L-7100
L-7100
AS-7200 Autosampler
AS-7200, AS-7250 Injection Valve
L4000, L4200, L4250, L7400
price
Phone: 800-356-1688 or 814-353-1300
www.restek.com
H P LC ACC E S S O R I E S
Put Outlet Cap on
male part of
Assembly Tool.
344
Replacement Parts
Restek Replacement Parts for PerkinElmer HPLC Systems
Description
Inlet Check Valve
Outlet Check Valve
High Pressure Seal Kit
Standard High Pressure Seal
Low Pressure Seal
Needle
H P LC ACC E S S O R I E S
Deuterium Lamp
Deuterium Lamp
Model #
PE 200, 4, 250, 400, 410, 620
PE 200, 4, 250, 400, 410, 620
PE Series 200 Pumps--1, 2, 3, 3B, 4,
10, 250, 400, 410, 620, Int. 4000 Pump
PE Series 200 Pumps--1, 2, 3, 3B, 4,
10, 250, 400, 410, 620, Int. 4000 Pump
PE Series 200 Pumps
PE Series 200 Pumps
PE Lambda--2, 5, 7, 8, 10, 11, 12, 14,
15, 16, 17, 18, 19, 20, 40, 800, 900
PE 200/785A
Similar to
PerkinElmer part #
2540177
2540197
qty.
ea.
ea.
cat.#
25438
25437
2540275
ea.
25433
9907324
9907339
N2930023
ea.
ea.
ea.
25434
25435
25432
B0160917
N2920149
ea.
ea.
25436
25431
Similar to
Shimadzu part #
228-12353-91
228-18522-91
228-39093-92
228-32166-91
228-09054-93
228-11200-91
228-18522-92
228-34976-91
228-11999-00
228-21975-00
228-18745-00
228-35146-00
228-32628-00
228-35145-00
228-28499-00
228-12904-93
228-17019-93
228-18523-91
228-33355-04
228-21217-97
228-21217-91
228-21220-91
228-25237-04
228-35601-91
228-35009-92
228-35601-92
062-65056-02
228-34016-02
qty.
ea.
ea.
ea.
ea.
ea.
2-pk.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
cat.#
25287
25295
24984
26521
25288
25289
25282
24983
25285
25290
25293
24980
24981
24985
25292
25286
25291
25294
25468
24986
25469
25470
25471
25472
25473
24982
25283
25284
price
Restek Replacement Parts for Shimadzu HPLC Systems
Inlet Check Valve
(cat.#26521)
Description
Inlet Check Valve
Inlet Check Valve
Inlet Check Valve
Inlet Check Valve
Outlet Check Valve
Outlet Check Valve Rebuild Kit
Outlet Check Valve
Outlet Check Valve
Plunger Seal
Plunger Seal, Polyethylene
Plunger Seal
Plunger Seal
Plunger Seal, Gold
Plunger Seal
Plunger Rinse Seal
Sapphire Plunger
Sapphire Plunger
Sapphire Plunger
Needle Seal
Rotor Seal
Rotor Seal Assembly
Stator Assembly
Syringe, 500µL
Plunger Assembly, Ceramic
Plunger Assembly, Ceramic
Plunger Assembly, Sapphire
Deuterium Lamp
Deuterium Lamp
Paula Zuchowski
Customer Service
Representative
5+ years of service!
Phone: 800-356-1688 or 814-353-1300
www.restek.com
Model #
LC-6A, LC-10AS
LC-600, LC-9A, LC-10AD
LC-10ADvp
LC-10AT, LC-10ATvp
LC-6A, LC-10AS
LC-6A, LC-10AS
LC-600, LC-9A, LC-10AD, LC-10AT
LC-10ADvp, LC-10ATvp
LC-6A
LC-10AS, LC-10AT, LC-10ATvp
LC-600, LC-9A, LC-10AD
LC-10ADvp, LC 20AD
LC-10ADvp
SIL-10ADvp, LC-10ATvp
LC-10AS
LC-6A
LC-10AS
LC-600, LC-9A, LC-10AD
SIL-10A, 10XL, 10ADvp
SIL-10ADvp
SIL-10A, 10AXL
SIL-10A, 10AXL
SIL-10A, 10AXL
LC-10ADvp
LC-10ATvp
LC-10ADvp
SPD-6A
SPD-10A, 10AV, M20A
price
Replacement Parts
345
Restek Replacement Parts for Thermo Separation HPLC Systems
Description
Inlet Check Valve Assembly
Outlet Check Valve Assembly
Piston
Back-up Seal
Plunger Seal, Gold Superseal
Check Valve and Transducer Assembly
Kel-F® Washer
qty.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
cat.#
25474
25475
25476
25477
25478
25479
25480
ea.
25481
ea.
ea.
25482
25483
ea.
25484
Description
Check Valve Cartridge
Sapphire Plunger
Plunger Seal Kit, Gold
Plunger Seal, Black
Plunger Seal, Gold
Similar to TSP part #
900946
801306
31-36-00754
206129001
206156001
qty.
ea.
ea.
ea.
ea.
ea.
cat.#
25485
25486
25487
25488
25489
108035
900918001
ea.
ea.
25490
25491
Model #
LDC Constametric Pumps
LDC Constametric Pumps
LDC Constametric Pumps
LDC Constametric Pumps
LDC Constametric Pumps
LDC SM-I, II, III, 3000, 3100, 3100X, and
4000 Detectors
LDC 3200 and 4100 Detectors
Lamp, Deuterium
Lamp, Deuterium Pre-aligned
price
Piston
Syringe Assembly, 250μL
price
Lamp, UV
Inlet Check Valve
Assembly
Restek Rheodyne® Style Replacement Parts for Waters HPLC Systems
Description
7010 Vespel® Rotor Seal
7125 Vespel® Rotor Seal
Isolation Seal, 7010
Similar to Rheodyne® part #
7010-039
7125-047
7010-015
qty.
ea.
ea.
ea.
cat.#
25279
25280
25281
price
qty.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
cat.#
25423
25424
25427
25404
25405
25403
25406
25407
25408
25409
25410
price
7125 Vespel® Rotor Seal
(both sides shown)
For easy access to Rheodyne® fittings, use a ValvTool Wrench—see page 357.
Restek Replacement Parts for Waters Detectors
Description
Window Gasket
Lamp Side Gasket
Quartz Lens
Xenon Lamp (w/o holder or mirror)
Xenon Lamp
Deuterium Lamp (UV/Vis)
Deuterium Lamp (UV/Vis)
Deuterium Lamp (UV/Vis)
Deuterium Lamp
Deuterium Lamp
Deuterium Lamp, long life (2000 hours)*
Model #
484, 486, 490
484, 486, 490
486
470
474
480, 481
484
486
996, 2996
2487
486
Similar to
Waters part #
80335
80336
80687
—
—
99499
80357
80678
WAT052586
WAS081142
80678
*Standard lamps have nominal 1000-hour life.
also available
HPLC autosampler syringes. See pages 296-297.
Phone: 800-356-1688 or 814-353-1300
www.restek.com
H P LC ACC E S S O R I E S
Model #
Similar to SP/TSP part #
SP8800 & P-Series Pumps
A3495-010
SP8800 Series Pumps
A3490-010
SP8800 & P-Series Pumps
A3102-010
SP8800 & P-Series Pumps
A2963-010
SP8800 & P-Series Pumps
A2962-010
P-Series Pumps
A3990-010
P-Series Pumps
A2973-010
TSP AS100, 300, 1000, 3000, 3500, 8875,
®
and 8880 Autosamplers
7010-039
Rotor Seal Assembly, Rheodyne 7010
TSP AS100, 300, 1000, 3000, 3500, 8875,
Syringe Assembly, 250µL
and 8880 Autosamplers
A3588-020
Syringe, 500µL
8800 Series
3301-0100
Linear UV-200, 203, 204, 205, 206, and UV
Lamp, UV
100, 150, 1000, and 2000 Detectors
9551-0023
346
Replacement Parts
H P LC ACC E S S O R I E S
Restek Replacement Parts for Waters HPLC Systems
Preventative Maintenance
Kit for 717 Autosampler
new!
Inlet Check Valve
Assembly
717 Seal Pack (Rebuilt)
with Needle
Description
Preventative Maintenance Kit Includes:
sparge diffuser, filter insert, compression screws,
SS ferrule, battery for 2690/717, 250µL WISP™ syringe,
seal wash plunger seal kits (2), wash tube seal kits (4),
2690 seal pack rebuild kit (steel bodies not included),
2690 head plunger seal kits (2), solvent reservoir 20µm
filters (4), Alliance® check valve cartridges (2), Alliance®
plunger assemblies (2), 2690 face seals (4)
Preventative Maintenance Kit Includes:
PerformancePLUS™ cartridges (2), sparge diffusers (4),
Super Seals™ (2), solvent reservoir 20µm filters (2),
sapphire plungers (2), reference valve rebuild kit, inlet
manifold kit
Preventative Maintenance Kit Includes: 717 seal pack
with needle, filter insert, 250µL WISP™ syringe
Preventative Maintenance Kit Includes:
616/326/625 plunger assemblies (2), pump seal kit,
sparge diffusers (4), solvent reservoir 20µm filters (4),
616 cartridge assemblies (4)
Preventative Maintenance Kit Includes:
PerformancePLUS™ check valves (2), sparge diffuser,
solvent 10µm filter, sapphire plungers (2),
plunger seals (2)
Inlet Check Valve Assembly
Inlet Check Valve Housing
Inlet Check Valve Rebuild Kit
Outlet Check Valve Assembly (Actuator Style)
Outlet Check Valve Housing (Actuator Style)
Outlet Check Valve Rebuild Kit (Actuator Style)
Outlet Check Valve Assembly (Ball & Seat Style)
Outlet Check Valve Housing (Ball & Seat Style)
Outlet Check Valve Rebuild Kit (Ball & Seat Style)
Inlet Check Valve Assembly, 225µL (Extended Flow)
PerformancePLUS™ Check Valve Cartridge
Check Valve Rebuild Kit (Extended Flow)
PerformancePLUS™ Check Valve Housing
Check Valve Cartridges
Super Seal™ for Analytical Heads
Plunger Seal, Gold for Analytical Heads*
Plunger Seal, Black for graphite-filled Teflon®
Plunger Seal, Black for EF Heads
Plunger Seal, Gold for EF Heads
Seal Wash Plunger Seal
Head Plunger Seal Kit
Head Plunger Seal Kit (Black)
Insert Seal Parts Kit
Sapphire Plunger
Sapphire Plunger (Extended Flow)
Sapphire Plunger
Sapphire Plunger Assembly Kit
Sapphire Plunger
Sapphire Plunger
Pressure Transducer
Draw-Off Tube Assembly
Inlet Manifold Kit
Ferrule, Stainless Steel
Wash Face Seal
Wash Tube Seal Kit
Rebuild Kit, Reference Valve
Compression Screws, Stainless Steel
Battery
Seal Pack Rebuild Kit, without Seal Wash Tube Assembly
717 Seal Pack (Rebuilt) with Needle
Seal Kit, Pump
Cartridge Assembly, Stainless Steel
*Ultra-high molecular weight polyethylene (UHMWPE).
Phone: 800-356-1688 or 814-353-1300
www.restek.com
Model #
Similar to
Waters part #
qty.
cat.#
Alliance® 2690, 2695
WAT270944
kit
25143
600 Pump
WAT052675
kit
25144
717 Autosampler
WAT052669
kit
25145
616 Pump
WAT052672
kit
25146
515 Pump
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
Alliance®
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
M6KA, 501, 510, 515, 590, 600E
510, 590, 600E
510, 590, 600E
Alliance®
Alliance®
Alliance®
M6KA, 501, 510, 515, 590, 600E
M6KA, 510, 590, 600
510, 590, 600E
M45, M501
M515
616, 625, 626
Alliance®
M6KA, M45, 501, 510, 590, 600E
510, 515, 600, 610
M45, 501, 510, 590, 600E
515
Alliance® 2690
Alliance® 2690
600 Pump
Alliance® 2690
Alliance® 2690, 717, 486, 484
Alliance® 2690
717 Autosampler
616 Pump, 626, 625
616 Pump
WAT052587
33679, 25214
25203
60495
25030
25212
26016
25216
25207
26014
60307
700000254
88223
—
WAT270941
22946, 22934
22934
26613
26644
26644
WAT271018
WAT270938
WAT271066
60012
25656
60304
26524
WAS207069
31788
WAT270959
WAT060329
25470
60448
22330
WAT271017
WAT270940
25746
—
—
WAT271019
4559
31790
24960
kit
ea.
ea.
2-pk.
ea.
ea.
2-pk.
ea.
ea.
2-pk.
ea.
2-pk.
2-pk.
ea.
2-pk.
ea.
ea.
ea.
ea.
ea.
2-pk.
2-pk.
2-pk.
kit
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
kit
ea.
ea.
4-pk.
ea.
2-pk.
ea.
ea.
ea.
ea.
ea.
26519
25360
25361
25362
25363
25364
25365
25366
25367
25368
25369
25370
25371
25372
25373
25374
25375
25378
25379
25380
25386
25387
25388
25389
25381
25382
25383
25384
25420
25385
25391
25392
25412
25417
25428
25429
25492
25493
25494
25495
25496
25497
25498
price
Valves
347
ASI Piston Seals for Agilent HPLC Systems
Over time the piston seal in every HPLC system becomes worn and must be replaced. Our piston seals are
constructed of Teflon® material with an additive that reduces their tendency to “cold flow” and improves
their wear characteristics. Teflon® seals are more resistant to any HPLC solvent than UHMWPE seals, but
they are less wear resistant and rugged. For Agilent 1050 and 1100 HPLC systems.
Description
ASI Piston Seal
ASI Piston Seal
qty.
ea.
10-pk.
cat.#
25175
25176
price
ASI subjects each valve to a rigorous series of tests, including self-priming capability, which means you
typically won’t need a syringe or draw-off valves to prime your pump. A high-pressure test ensures that
the valve will not leak, even at pressures up to 12,000psi (82,737kPa). A low-pressure test verifies that the
valve closes properly, even without a high backpressure force. The cartridge design allows easy, convenient
replacement of worn or damaged valves.
ASI Check Valves for Agilent 1050 & 1100
Description
Outlet Check Valve (cartridge and housing)
Outlet Check Valve (cartridge and housing)
Outlet Cartridges
Outlet Cartridges
Outlet Housing
Material
Sapphire & Ruby Ball & Seat
Ceramic Ball & Seat
Sapphire & Ruby Ball & Seat
Ceramic Ball & Seat
—
qty.
ea.
ea.
ea.
ea.
ea.
cat.#
25170
25173
25171
25174
25172
price
qty.
ea.
ea.
cat.#
25160
25162
price
Inlet and Outlet Check
Valves for Waters
Instruments
ASI Check Valves for Waters Alliance® Model 2690
Description
Inlet and Outlet Cartridges
Inlet and Outlet Cartridges
Material
Sapphire & Ruby Ball & Seat
Ceramic Ball & Seat
Valves for HPLC
Our valves have low internal volumes and are rated to 15,000psi (103,421kPa). They feature a 2-piece stem
assembly in which the rotating upper shank is coupled through a ball joint to a static lower stem. Only
fingertight torque is required to make the seal.
Description
Two-Way Through Valve for HPLC,
1
/16" Fittings, 1/4-28, Stainless Steel, Includes Nuts and Ferrules
Two-Way Angle Valve for HPLC,
1
/16" Fittings, 1/4-28, Stainless Steel, Includes Nuts and Ferrules
Three-Way Bottom Vent Valve for HPLC,
1
/16" Fittings, 1/4-28, Stainless Steel, Includes Nuts and Ferrules
Side Vent Valve for HPLC,
1
/16" Fittings, 1/4-28, Stainless Steel, Includes Nuts and Ferrules
Dual Stem Three Way Valve for HPLC,
1
/16" Fittings, 1/4-28, Stainless Steel, Includes Nuts and Ferrules
Prime/Purge Valve for HPLC,
1/4-28 Flanged Seat, Stainless Steel, with Tubing and Fittings
Prime/Purge Valve Repair Kit for Prime/Purge Valve
qty.
cat.#
ea.
26400
ea.
26401
ea.
26402
ea.
26403
ea.
26404
ea.
kit
26406
26407
price
Side Vent Valve
In-Line Check Valves for HPLC
Our 316 stainless steel in-line check valves have a soft seat and 1/16" fittings. Nuts and ferrules are
included.
Description
Check Valve, Soft Seat, for HPLC, 1/16" Fittings, 1/4-28, Stainless Steel,
Includes Nuts and Ferrules
qty.
cat.#
ea.
26405
price
Phone: 800-356-1688 or 814-353-1300
www.restek.com
H P LC ACC E S S O R I E S
ASI Check Valves
348
Filters
High-Pressure Frit-Type In-Line Filter
Restek’s high-pressure in-line filter is a stand-alone version of the Trident column protection system,
specifically designed for ease of use, low dead-volume, and flexibility. The filter has a replaceable, PEEK™
encapsulated 316 stainless steel frit with a surface area of 12mm2. The standard frit with 2.0µm porosity
may be replaced with an optional 0.5µm porosity frit. Use of this filter can greatly extend column life,
thereby reducing costs and saving maintenance time. Tubing OD 1/16"; connectors–CPI.
H P LC ACC E S S O R I E S
Flow
Description
Frit-Type In-Line Filter
Replacement Cap Frits: 4mm
Replacement Cap Frits: 4mm
Porosity
2.0µm
0.5µm
2.0µm
qty.
ea.
5-pk.
5-pk.
cat.#
25041
25023
25022
price
High-Pressure Cup-Type In-Line Filter
This high-pressure cup-type filter can be used in fluid streams operating to 15,000psi (103,421kPa). The
cup-shaped filter elements have a large (2.5 cm2) surface area to give long operating lifetime. Mounted in
screw-type adapters, they are easily removed for cleaning. Normally, backflushing and cleaning in an
ultrasonic bath with an appropriate solvent will restore them. If they become permanently clogged,
replacement elements are available.
Housings and all wetted parts are 316 stainless steel. Filters are packaged with gland nuts and ferrules. A
bulkhead type fitting is available for thru-panel mounting. Tubing OD 1/16"; connectors–CPI.
Description
Cup-Type In-Line Filter
Cup-Type In-Line Filter
Replacement Filter Elements & Seals
Replacement Filter Elements & Seals
Porosity
0.5µm
2.0µm
0.5µm
2.0µm
qty.
ea.
ea.
2-pk.
2-pk.
cat.#
25000
25001
25002
25003
price
Low-Pressure Slip-On Inlet Filter for Mobile Phase Reservoir
A type 316 stainless steel tip with a Tefzel® collar seals to a corrosion-resistant type 316 stainless steel
filter element. The slip-on filter easily attaches to the pump inlet line, without the use of wrenches. The
universal tip accommodates standard Teflon® tubing inner diameters. The cylindrical filter is standard
10µm porosity. 1/8" OD. Fits Altex, ISCO, LDC, Varian, Waters, PerkinElmer, and other pumps.
Description
Slip-on Inlet Filter
qty.
ea.
cat.#
25008
price
Low-Pressure CPI Inlet Filter for Mobile Phase Reservoir
A 316 stainless steel knurled cap and Tefzel® CPI ferrule seal to 1/8" OD Teflon® tubing when fingertightened onto the precision-machined filter holder. The filter element is replaceable. Standard 10µm
porosity protects delicate pump components from particles but introduces very little pressure drop.
1
/8" OD. May be used as a helium sparging diffuser.
Description
CPI Inlet Filter
Replacement Elements: 10µm filter
also available
Trident Direct high-pressure filter—
protection against particulate matter.
See page 338 for details.
Phone: 800-356-1688 or 814-353-1300
www.restek.com
qty.
ea.
2-pk.
cat.#
25009
25010
price
Filters
349
Mobile Phase Sparge Filter; Inlet Filter
The 2µm helium sparge filter is an inexpensive way to prepare and maintain mobile phases free of dissolved
gas. Both filters are made from 316 stainless steel and PEEK™ and are compatible with most solvents.
Description
Mobile Phase Sparge Filter: 2µm
Inlet Filter: 10µm
Inlet Filter: 20µm
qty.
ea.
ea.
ea.
cat.#
25311
25312
25313
price
H P LC ACC E S S O R I E S
Last Drop Filter
The flat filter element sits parallel to the bottom of the mobile phase reservoir, allowing the filter to draw
98% of the mobile phase without drawing air into the system. Conventional cylindrical mobile phase filters begin to draw air into the system when approximately 10% of the solvent remains in the reservoir.
The Last Drop Filter allows more analyses per batch of mobile phase and helps reduce hazardous waste.
22.1mm OD.
Description
Last Drop Filter: 2µm
Last Drop Filter: 10µm
qty.
ea.
ea.
cat.#
25314
25315
price
Membrane Microfiltration Glassware
47mm filtration apparatus with fritted glass support is recommended for routine filtration of corrosive
liquids and removal of particles from HPLC solvents. The ground joint connection eliminates phthalate
contamination that can occur when using silicone or neoprene stoppers. The support base has a coarse
porosity glass frit and an integral vacuum connection, located above the drip tip to prevent contamination of the vacuum line with filtrate droplets. Each apparatus includes a funnel, an anodized aluminum
clamp, a 47mm fritted glass support base, and a filtration flask.
All-Glass Microfiltration Apparatus
300mL Funnel, 1000mL Flask
500mL Funnel, 2000mL Flask
1000mL Funnel, 4000mL Flask
Replacement Parts for Microfiltration Apparatus
40/35 PTFE Joint Sleeve
Flask Cap, 40/35 Outer Joint
Fritted Glass Support, 47mm, 40/35 Joint
Glass Funnel, 47mm, 100mL
Glass Funnel, 47mm, 300mL
Glass Funnel, 47mm, 500mL
Glass Funnel, 47mm, 1000mL
Flask, 1000mL, 40/35 Joint
Flask, 2000mL, 40/35 Joint
Flask, 4000mL, 40/35 Joint
Aluminum Clamp, 47mm
Membrane Filters
Polyproylene Membrane Filters, 47mm, 0.45µm
Polyproylene Membrane Filters, 47mm, 0.22µm
Nylon Membrane Filters, 47mm, 0.45µm
Nylon Membrane Filters, 47mm, 0.22µm
qty.
ea.
ea.
ea.
qty.
6-pk.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
qty.
100-pk.
100-pk.
100-pk.
100-pk.
cat.#
KT953825-0000
KT953835-0000
KT953845-0000
cat.#
KT676001-4035
KT953830-0000
KT953826-0000
KT953761-0000
KT953751-0000
KT953771-0000
KT953781-0000
KT953827-0000
KT953828-0000
KT953829-0000
KT953753-0000
cat.#
26396
26397
26398
26399
price
price
price
new!
Polypropylene
Membrane Filters
tech tip
Mobile Phase Additives
Mobile phase additives such as triethylamine, trifluoroacetic acid, and ion-pairing reagents can compete with sample ions, decreasing
sensitivity and, in some cases, reducing sample ion intake into the MS. To obtain symmetric peaks and/or sufficient retention, use base
deactivated, state-of-the-art Type B silica packings that minimize the need for additives.
Phone: 800-356-1688 or 814-353-1300
www.restek.com
350
Mobile Phase Accessories
H P LC ACC E S S O R I E S
Degasys Ultimate
Degasser provides
highly stable
baselines
LC_0196
Ultimate
Degasser
Off
Ultimate
Degasser
On
Mobile Phase: water:methanol
50:50
Flow:
1.0 mL/min.
Det.:
UV @ 210nm
Mobile Phase Degasser
Dissolved oxygen can cause flow rate instability and
increased baseline noise. Also, it has a quenching
effect on fluorescence detection and increases the
background of UV detectors. Dissolved gases can
out-gas in the HPLC system, forming bubbles in
check valves, at connections, or in detector flow
cells.
In-line vacuum degassing is more effective at
removing dissolved gas from mobile phases than
sonication or helium sparging. In-line degassers
work by withdrawing gas across a gas-permeable
membrane encased in a sealed chamber. Traditionally, the membrane has been made of PTFE tubing, but
the Degasys Ultimate Degasser uses tubing composed of an amorphous fluoropolymer that is 200 to 300
times more gas permeable than PTFE. This translates into the ability to use shorter tubing for removing
dissolved gas. This new material also has better tubular burst strength than PTFE. To prevent cross contamination, each channel on this Degasys unit is individually encased within its own vacuum chamber.
Specifications:
Residual Oxygen1
0.9ppm
Pressure Loss1
0.24psi (1.65kPa)
Internal Volume
500µL
Wetted Parts
Teflon® AF, PTFE, ETFE, PPS
Max Flow Rate
7mL/min./channel
At a flow rate of 1mL/min.
1
Description
110V Mobile Phase Degasser (4 Channel, 7mL/min./channel)
220V Mobile Phase Degasser (4 Channel, 7mL/min./channel)
qty.
ea.
ea.
cat.#
25189
25194
price
Do not use the Degasys system with solutions containing TFA at concentrations greater than 5%.
Solvent Debubbler
Bubbles in an HPLC system can cause check valve malfunctions and pump cavitation, seriously affecting
pump performance. The debubbler removes bubbles from the fluid stream before it enters the pump.
Special geometry at the base of the housing allows bubbles entrained in the inlet fluid stream to rise and
be trapped in the reservoir. The gas/liquid interface is easily visible through the translucent wall of the
device. Loosening the airtight cap releases the trapped gas. The debubbler is fitted with a bracket and
universal connecting tips.
Description
Solvent Debubbler with Bracket
qty.
ea.
cat.#
25014
price
Sonic Debubbler
• Fast.
• Easy to use.
• Less solvent waste; less clean-up.
Just touch the Sonic Debubbler to the inlet line or check valve — sonic vibrations will quickly dislodge or
redissolve trapped air bubbles. Reduces downtime or conversion time from one mobile phase to another.
Description
Sonic Debubbler (110V)
Sonic Debubbler (220V)
Phone: 800-356-1688 or 814-353-1300
www.restek.com
qty.
ea.
ea.
cat.#
20444
25098
price
Bottle Tops
351
Opti-Cap™ Bottle Top
The most economical way to helium-sparge and deliver HPLC mobile phases. The Opti-Cap™ top fits all
standard GL45 bottles and has two 1/8-inch holes and one 1/16-inch hole for tubing.
qty.
ea.
kit
kit
kit
qty.
ea.
ea.
3m
3m
3-pk.
ea.
ea.
cat.#
25300
25301
25302
25303
cat.#
25311
25312
25307
25306
25319
25304
25305
price
price
Opti-Cap™ Kit with bottle
Eco-Cap Bottle Top, PTFE
Fits all standard GL-45 bottles; has two 1/8-inch holes and one 1/16-inch hole for tubing.
Description
Eco-Cap Bottle Top, includes 1 Male Luer Plug
qty.
ea.
cat.#
25395
price
also available
See page 352 for Hub-Cap bottle tops, adapters, and filter kits.
Technical Service Specialists
Al Carusone, Tom Bloom, Jonathan Keim, Tim Herring, Alan Sensue, Terry Reid
Phone: 800-356-1688 or 814-353-1300
www.restek.com
H P LC ACC E S S O R I E S
Description
Opti-Cap™ (Cap and PEEK™ Plug)
Opti-Cap™ Kit (Opti-Cap™, 3 meters of tubing, sparging filters)
Opti-Cap™ Kit with 1L Bottle
Opti-Cap™ Kit with 2L Bottle
Related items and replacement parts
SS Mobile Phase Mobile Phase Sparge Filter: 2µm
Mobile Phase Inlet Filter: 10µm
Teflon® Tubing, 1/8" OD x 0.094" ID x 3m (2.4mm ID)
Teflon® Tubing, 1/8" OD x 0.063" ID x 3m (1.6mm ID)
PEEK™ Plug, 1/4"-28 threads
1L Graduated Safety-Coated Bottle – GL-45 threads
2L Graduated Safety-Coated Bottle – GL-45 threads
352
Bottle Tops
Hub-Cap 4 Liter Bottle Tops
Most bottles use a GL45 cap. New Hub-Cap
bottle tops are a great way to neatly keep your
mobile phase lines where they belong. Use
instead of parafilm, aluminum foil, or tape on
your mobile phase reservoirs.
H P LC ACC E S S O R I E S
Hub-Cap (assembly of the
bottle cap and plug)
Description
Hub-Cap (assembly of the bottle cap and plug)
Hub-Cap Multi-pack
qty.
kit
3-pk.
cat.#
26541
26542
price
qty.
ea.
3-pk.
kit
cat.#
26538
26539
26540
price
Hub-Cap Adapters
Allow the use of the Opti-Cap™ with 4-liter solvent bottles.
Hub-Cap
Adapter
Hub-Cap
Adapter
and
Opti-Cap™
new!
Transfer and filter
mobile phase in a
single step!
Description
Hub-Cap Adapter
Hub-Cap Adapter Multi-pack
Hub-Cap Adapter and Opti-Cap™
Hub-Cap Filter Kit
Kit includes: bottle adapter, bottle adapter nut, filter inlet cap, grid support,
vacuum hose barb, tube compression fitting, 47mm grid, 47mm .22µm filter
membrane, 47mm .45µm filter membrane, 1/4" OD x 1/8" ID ultra chemical
resistant, Teflon® FEP lined Tygon® tubing (3'), 6" x 6" box with shrink wrap
insert
Hub-Cap Filter Kit
Unscrew and lift off top.
Polypropylene
Membrane Filters
Place membrane filter on top of
grid.
Description
Hub-Cap Filter Kit
Replacement Membrane Filters
Polyproylene Membrane Filters, 47mm, 0.45µm
Polyproylene Membrane Filters, 47mm, 0.22µm
Nylon Membrane Filters, 47mm, 0.45µm
Nylon Membrane Filters, 47mm, 0.22µm
Phone: 800-356-1688 or 814-353-1300
www.restek.com
Reattach top.
qty.
kit
qty.
100-pk.
100-pk.
100-pk.
100-pk.
Connect vacuum line to side
port.
cat.#
26395
cat.#
26396
26397
26398
26399
price
price
Column Heater and Heater/Cooler, Gas Trapping System
353
Sidewinder Column Heater
•
•
•
•
Easy to set up!
Operation range: 5°C above ambient to 85°C, ±1°C.
Lightweight, compact design fits in small spaces.
Column holder can be placed in any orientation.
Description
Temperature Control Module and Long Column Holder (25cm)
Temperature Control Module and Short Column Holder (10cm)
qty.
ea.
ea.
cat.#
26516
26517
price
Sidewinder temperature
control module
Sidewinder Heater/Cooler Temperature Control Module
•
•
•
•
Operation range: 5-55°C, ±0.2°C.
Ability to program multiple temperature points.
Accommodates columns up to 30cm in length and 7.8mm ID.
Compact design.
The Sidewinder heater/cooler unit has a doubly insulated cover to maintain the programmed temperature to within 0.2°C. The 24V control unit provides maximum stability and rapid equilibration times;
RS232 control allows external programming.
Description
Sidewinder Heater/Cooler Temperature Control Module
qty.
ea.
cat.#
26518
price
cat.#
22484
price
Mobile Phase Pre-heater
• Heats mobile phase before it enters a heated column.
• Minimizes temperature changes, to help keep analyte peaks sharp.
Description
Mobile Phase Pre-heater
qty.
ea.
Super-Clean™ Gas Trapping System for LC/MS
2-Position Base Plate
• Changing filters is quick and easy.
• Up to 20L of hydrocarbon-free nitrogen per minute.
The Super-Clean™ Gas Trapping System is the latest technology in
cartridge-style gas filtration for purifying nitrogen, and is ideal for
use in LC/MS systems. The two-position base plate (installed in the
gas line) allows cartridges to be exchanged without introducing oxygen into the system. Spring-loaded
check valves seal when a cartridge is removed and open only when a new cartridge has been locked in
place. There is no need for loosening and tightening fittings every time you change cartridges, and your
system cannot become contaminated during the changing process.
it’s a fact
A Super-Clean™ quick-change
cartridge system efficiently
removes hydrocarbons from
nitrogen!
To meet the high flow needs of the LC/MS system, the activated charcoal-filled cartridges are positioned
and connected in parallel. The incoming gas stream is split equally between the cartridges, and the two
streams are rejoined after purification but before the gas exits the base plate. This approach allows longer
contact between the nitrogen and the adsorbent, ensuring higher gas purity and eliminating a potential
source of contaminants to your analyses.
A handy date wheel, included with the system, indicates the cartridge installation date and the recommended replacement date.
Description
Super-Clean™ Gas-Trapping System (2-position base plate, 2 charcoal filters)
2-Position Base Plate (1/4" Fittings) for use with hydrocarbon filters (cat.# 22061)
Replacement Hydrocarbon (Charcoal) Filters
qty.
ea.
ea.
2-pk.
cat.#
22062
22060
22061
price
Charcoal Filters
Phone: 800-356-1688 or 814-353-1300
www.restek.com
H P LC ACC E S S O R I E S
This unique design completely encloses any HPLC analytical column up to 25cm in length. Two lengths
of heater jackets are available: the short column holder accommodates columns up to 10cm in length,
while the long column holder holds columns up to 25cm in length. The control module provides optimum heating performance, accuracy to within 1°C, and stability to within 0.1°C. The new Sidewinder
controller has fast 10Hz sampling for improved responsiveness. Power requirements: 24V control unit for
maximum stability; RS232 control allows external programming.
354
Survival Kits
PEEK™ Survival Kit for HPLC
The PEEK™ Survival Kit is an invaluable parts kit that contains tubing, fittings, and tools essential for
setting up and maintaining your HPLC system: PEEK™ tubing, connectors, and elbows, Teflon® tubing,
a tubing cutter and extra blades, a ValvTool wrench, open-end wrenches, and more.
For start-up and maintenance in all HPLC systems.
Description
PEEK™ Survival Kit for HPLC
qty.
kit
cat.#
25322
price
qty.
10-pk.
ea.
ea.
ea.
5-pk.
5-pk.
3m
3m
5-pk.
ea.
2-pk.*
ea.
ea.
2-pk.
ea.
ea.
cat.#
25015
25065
25066
25067
25308
25309
25306
25307
25310
25321
20110
25069
25070
25323
25311
25312
price
H P LC ACC E S S O R I E S
Contents:
PEEK™ Survival Kit
Terry Reid
Technical Service
Specialist
9+ years of service!
Description
PEEK™ Column Connector (beige, round body)
PEEK™ Tubing, 1/16" OD x 0.005" ID x 3m (red stripe)
PEEK™ Tubing, 1/16" OD x 0.007" ID x 3m (yellow stripe)
PEEK™ Tubing, 1/16" OD x 0.010" ID x 3m (blue stripe)
PEEK™ Tubing Elbow 90°
PEEK™ Tubing Elbow 180°
Teflon® Tubing, 1/8" OD x 0.063" ID x 3m (1.6mm ID)
Teflon® Tubing, 1/8" OD x 0.094" ID x 3m (2.4mm ID)
Tubing Clip
ValvTool Wrench
Open-End Wrenches (1/4" x 5/16")
Clean-Cut™ Tubing Cutter
Replacement Blade for Clean-Cut™ Cutter
PEEK™ Union Connector 1/16"
Mobile Phase Sparge Filter: 2µm
Inlet Filter: 10µm
*Kit contains 1 wrench, replacement (cat.# 20110) is a 2-pk.
Stainless Steel Survival Kit for HPLC
The stainless steel survival kit contains a wide range of tubing, fittings, and tools necessary to set up and
maintain your HPLC system: a selection of lengths and IDs of 1/16-inch tubing, plus nuts, ferrules, a
ValvTool wrench, and a zero-dead-volume union.
Description
Stainless Steel Survival Kit for HPLC
qty.
kit
cat.#
25097
price
qty.
3-pk.
3-pk.
3-pk.
3-pk.
3-pk.
3-pk.
3-pk.
3-pk.
3-pk.
3-pk.
3-pk.
3-pk.
3-pk.
3-pk.
3-pk.
3-pk.
10-pk.
10-pk.
ea.
10-pk.
10-pk.
ea.
cat.#
25240
25241
25242
25243
25244
25245
25246
25247
25248
25249
25250
25251
25252
25253
25254
25255
25095
25096
25321
20286
20287
20148
price
Contents:
Stainless Steel Survival Kit
it’s a fact
Survival Kits are convenient
and economical, compared to
ordering individual items!
Description
HPLC Capillary Tubing, SS 1/16" x 0.005" x 5cm
HPLC Capillary Tubing, SS, 1/16" x 0.005" x 10cm
HPLC Capillary Tubing, SS, 1/16" x 0.005" x 20cm
HPLC Capillary Tubing, SS, 1/16" x 0.005" x 30cm
HPLC Capillary Tubing, SS, 1/16" x 0.007" x 5cm
HPLC Capillary Tubing, SS, 1/16" x 0.007" x 10cm
HPLC Capillary Tubing, SS, 1/16" x 0.007" x 20cm
HPLC Capillary Tubing, SS, 1/16" x 0.007" x 30cm
HPLC Capillary Tubing, SS, 1/16" x 0.010" x 5cm
HPLC Capillary Tubing, SS, 1/16" x 0.010" x 10cm
HPLC Capillary Tubing, SS, 1/16" x 0.010" x 20cm
HPLC Capillary Tubing, SS, 1/16" x 0.010" x 30cm
HPLC Capillary Tubing, SS, 1/16" x 0.020" x 5cm
HPLC Capillary Tubing, SS, 1/16" x 0.020" x 10cm
HPLC Capillary Tubing, SS, 1/16" x 0.020" x 20cm
HPLC Capillary Tubing, SS, 1/16" x 0.020" x 30cm
1
/16" Rheodyne® Style Nut
1
/16" Rheodyne® Style Ferrule
ValvTool Wrench
1
/16" Stainless Steel Ferrules
1
/16" Stainless Steel Nuts
Zero-Dead-Volume Internal Union
Phone: 800-356-1688 or 814-353-1300
www.restek.com
color
red
red
red
red
gray
gray
gray
gray
blue
blue
blue
blue
yellow
yellow
yellow
yellow
Fittings, Connectors, Tools
355
PEEK™ Fitting Extractor
Drill into the broken fitting, then screw the extractor into the fitting and remove it easily. Eliminates the
need for heat or other techniques that could damage your column.
qty.
ea.
cat.#
25325
H P LC ACC E S S O R I E S
Description
PEEK™ Fitting Extractor
price
PEEK™ Union Connector
Allows you to quickly and reliably connect two pieces of 1/16-inch tubing. 0.3mm union bore.
End fittings included.
Description
PEEK™ Union Connector 1/16"
qty.
2-pk.
cat.#
25323
price
Zero-Dead-Volume Valco® Internal Union
Ends of tubing seat squarely at bottoms of fitting details. 300 series stainless steel. For 1/16-inch OD tubing.
Stainless steel ferrules included.
Description
Internal Union
Internal Union
Internal Union
Internal Union
Union Bore
0.15mm
0.25mm
0.75mm
1
/16"
Valco® #
ZU1XC
ZU1C
ZU1
ZU1T
qty.
ea.
ea.
ea.
ea.
cat.#
20147
20148
20149
20150
price
Improving Column Connections
A good connection is necessary for trouble-free chromatography. Connecting incompatible fittings from
different manufacturers can result in leaks, poor peak shape, and increased void volume (Figure 1). Each
type of end-fitting has a unique seat depth or style. Generally, Restek, Valco®, Parker, and Upchurch®
Scientific fittings are interchangeable; whereas Waters, SSI, Rheodyne®, and Gasukura fittings are not
(Figure 2).
Figure 1
Incompatible fittings
create problems.
Our wrenchless universal 10-32 PEEK™ column connector (cat.# 25015, page 357) can be used with any
style of end fitting, and all 1/16-inch tubing. It is reusable and will adjust to any seat, depth, or style.
Tubing and ferrule
seated correctly
Figure 2 Fitting styles differ among various manufacturers.
Tubing not seated,
causing dead volume
Parker
Valco®
Swagelok® Parker A-Lok
Waters
Rheodyne®
Ferrule can’t seal
Phone: 800-356-1688 or 814-353-1300
www.restek.com
356
Fittings, Connectors, Tools
HPLC Piston Seal Insertion Tool
Simplify pump maintenance: use one end to remove your old seal, then simply slip your new seal on the
other end and push it flush into position. The tool cannot mar the surrounding metal surface of the pump
housing.
H P LC ACC E S S O R I E S
Remove
a seal
Seat
a seal
Use the flat side of the
Piston Seal Insertion
Tool to seat a Waters
face seal.
Description
HPLC Piston Seal Insertion Tool
qty.
ea.
cat.#
21356
price
Secure-Fit Fittings
A good connection between HPLC components is necessary for trouble-free chromatography. Secure-Fit
connectors from Restek and Selerity Technologies ensure a consistent, leak-free seal—and they eliminate
excess dead volume! An internal spring mechanism holds the capillary tubing at the proper depth in the
female fitting. This seal is maintained while you finger-tighten the nut. These fittings are available in stainless steel or PEEK™, and in a variety of tubing lengths and internal diameters.
Secure-Fit Fittings—Single Connectors
Length
6cm
10cm
20cm
30cm
50cm
0.005" ID
25181
25182
25183
25184
26510
Stainless Steel
0.007 " ID
25185
25186
25187
25188
26511
0.010 " ID
25190
25191
25192
25193
26512
0.005 " ID
25230
25231
25232
25233
—
PEEK™
0.007 " ID
25234
25235
25236
25237
—
0.010 " ID
25217
25218
25219
25220
—
price
0.010" ID
25214
25215
25216
26515
0.005 " ID
25221
25222
25223
—
PEEK™
0.007" ID
25224
25225
25226
—
0.010 " ID
25227
25228
25229
—
price
Secure-Fit Fittings—Two Connectors
Length
Stainless Steel
Secure-Fit Fitting
10cm
20cm
30cm
50cm
0.005" ID
25208
25209
25210
26513
Stainless Steel
0.007 " ID
25211
25212
25213
26514
PEEK™
Secure-Fit Fitting—Single Connector
Phone: 800-356-1688 or 814-353-1300
www.restek.com
Connectors, Tubing Accessories
357
PEEK™ Tubing Elbows
Tubing Elbows (90° and 180°) are ideal for routing 1/16-inch PEEK™ tubing through your system. Simply
snap the tubing into the elbow. Prevent pinching of PEEK™ tubing which can cause high pressure.
Description
PEEK™ Tubing Elbow 90°
PEEK™ Tubing Elbow 180°
qty.
5-pk.
5-pk.
cat.#
25308
25309
price
Tubing Dressing Tool
Opens stainless steel tubing bore and removes burrs. For 1/16-inch OD tubing or 1/8-inch OD tubing.
qty.
ea.
ea.
ea.
ea.
cat.#
20188
20189
20190
20191
H P LC ACC E S S O R I E S
Description
/16" Tubing Dressing Tool
Replacement Insert for 1/16" Tubing Dressing Tool
1
/8" Tubing Dressing Tool
Replacement Insert for 1/8" Tubing Dressing Tool
1
price
Clean-Cut™ Tubing Cutter
• Burr-free, perpendicular cuts that will not distort the tubing OD or close the ID.
• Use on PEEK™, Teflon®, Tefzel®, other polymeric tubing.
Description
Clean-Cut™ Tubing Cutter
Replacement Blade for Clean-Cut™ Cutter
qty.
ea.
ea.
cat.#
25069
25070
price
For stainless steel tubing cutters, see page 251 or 397 or visit www.restek.com.
Universal 10-32 PEEK™ Column Connectors and Plugs
Universal PEEK™ Connectors allow easy installation of all 1/16-inch tubing, including stainless steel.
See “Improving Column Connections” data on page 355.
Description
PEEK™ Column Connector (beige, round body)
PEEK™ Column Plug (black)
PEEK™ Fingertight Fittings (blue, flat-sided)
qty.
10-pk.
10-pk.
10-pk.
cat.#
25015
25016
25324
PEEK™ Column Connector
price
PEEK™ Fingertight Fittings
Rheodyne® Style Nut and Ferrule
Replacement long nut for connecting stainless steel tubing to a Rheodyne® 6-port valve or other
Rheodyne® part.
Description
/16" Rheodyne® Style Nut
1
/16" Rheodyne® Style Ferrule
1
qty.
10-pk.
10-pk.
cat.#
25095
25096
price
ValvTool Wrench
The ValvTool is a time-saving device that provides easy access to many hard-to-reach Rheodyne® or
Valco® valves. For 1/4-inch nuts.
Description
ValvTool Wrench
qty.
ea.
cat.#
25321
price
Phone: 800-356-1688 or 814-353-1300
www.restek.com
358
Tubing
Inert PEEK™ Tubing
•
•
•
•
Replaces stainless steel, titanium, Teflon® or Tefzel® tubing.
Less oxygen permeable and more temperature resistant (to 250°C) than Teflon® or Tefzel® tubing.
Use with PEEK™ fingertight or flangeless fittings.
Use to 7,000psi (48,263kPa).
H P LC ACC E S S O R I E S
Description
PEEK™ Tubing, 1/16" OD x 0.0025" ID x 1m
PEEK™ Tubing, 1/16" OD x 0.005" ID x 3m
PEEK™ Tubing, 1/16" OD x 0.007" ID x 3m
PEEK™ Tubing, 1/16" OD x 0.010" ID x 3m
PEEK™ Tubing, 1/16" OD x 0.020" ID x 3m
Color Code
pink dash stripe
red stripe
yellow stripe
blue stripe
orange stripe
qty.
3-pk.
ea.
ea.
ea.
ea.
cat.#
25320
25065
25066
25067
25068
price
HPLC Stainless Steel Capillary Tubing
•
•
•
•
316 grade stainless steel.
Precise pre-cut lengths.
Smooth surface finish.
Ultra clean.
Whether you need to replace system tubing as part of your troubleshooting or are looking to reduce the
dwell volume of your system as you move to narrower columns, Restek has the quality tubing in the
lengths and IDs you need. Each ID is color-coded so it is easy to identify and replace correctly.
Length
1
/16" OD Tubing
5cm
10cm
20cm
30cm
qty.
0.005 " ID (red)
cat.#
price
0.007 " ID (gray)
cat.#
price
0.010 " ID (blue)
cat.#
price
3-pk.
3-pk.
3-pk.
3-pk.
25240
25241
25242
25243
25244
25245
25246
25247
25248
25249
25250
25251
0.020 " ID (yellow)
cat.#
price
25252
25253
25254
25255
Teflon® Tubing
• Ideal for mobile phase inlet lines.
• Chemically inert.
• Use to 500psi (3,447kPa) and 80°C.
Description
Teflon® Tubing, 1/8" OD x 0.063" ID x 3m (1.6mm ID)
Teflon® Tubing, 1/8" OD x 0.094" ID x 3m (2.4mm ID)
qty.
3m
3m
cat.#
25306
25307
price
Tubing Clip
Securely holds 1/16-inch or 1/8-inch tubing in beaker, flask, or bottle up to 4mm thick.
Description
Tubing Clip
Phone: 800-356-1688 or 814-353-1300
www.restek.com
qty.
5-pk.
cat.#
25310
price
Flow Splitters, Static Mixers
359
QuickSplit™ Post-Column Flow Splitters
Fluid resistor technology eliminates adjustments to capillary tubing for optimizing split ratio. Wide
range of interchangeable resistors available.
Fixed Flow Splitters for HPLC & LC/MS
•
•
•
•
Split ratio not affected by changes in viscosity or pressure.
High operating pressure limit: 10,000psi (68,948kPa).
Low dead volume—negligible effect on analyte bandwidth.
Total flow: 0.1–5.0mL/min.
Adjustable Flow Splitter
Adjustable metering valve gives convenient control of split ratio.
Split ratio not affected by changes in viscosity or pressure.
High operating pressure limit: 5,000psi (34,474kPa).
Low dead volume—negligible effect on analyte bandwidth.
Total flow: 0.1–5.0mL/min.
Description
Binary Fixed Flow Splitter
Replacement Fixed Flow Splitter Resistor Set
Adjustable Flow Splitter
Replacement Adjustable Flow Splitter Resistor Set
Split Ratio
100:01:00
50:01:00
20:01
10:01
5:01
100:01:00
50:01:00
20:01
10:01
5:01
5:1 to 100:1
1:1 to 20:1
50:1 to 1000:1
5:1 to 100:1
1:1 to 20:1
qty.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
cat.#
25326
25327
25328
25329
25330
25331
25332
25333
25334
25335
25336
25337
26416
25338
25339
price
also available
We are pleased to offer
HPLC accessory items from
Analytical Scientific
Instruments (ASI). ASI
specializes in HPLC system
components and parts that
often exceed the original
equipment manufacturer’s
performance. See page 347.
HyperShear™ HPLC Mixers
•
•
•
•
Reduced baseline noise.
Increased sensitivity.
Improved gradient accuracy, for more reproducible results.
Increased reaction efficiency in post-column derivatization.
An efficient cross-flow shearing mechanism and interchangeable cartridges produce vortex shear mixing
over a wide range of flows. Stainless steel or PEEK™.
HyperShear™ Static In-Line Mixers
Description
1µL In-Line Mixer
25µL In-Line Mixer
50µL In-Line Mixer
150µL In-Line Mixer
250µL In-Line Mixer
qty.
ea.
ea.
ea.
ea.
ea.
Stainless Steel
cat.#
26409
26411
25341
25342
25343
price
qty.
ea.
ea.
ea.
ea.
ea.
PEEK™
cat.#
26410
26412
26413
26414
26415
price
Ternary Tee Mixer
Description
25µL Ternary Tee Mixer
qty.
ea.
cat.#
25138
price
Phone: 800-356-1688 or 814-353-1300
www.restek.com
H P LC ACC E S S O R I E S
•
•
•
•
•
360
Pulse Dampers, Backpressure Regulators
FlatLine™ Pulse Damper
• Rupture-proof, no diaphragm—minimal risk of failure or leaks.
• Clean flush-out design—no sample carryover.
• Low internal volume—negligible effect on analyte bandwidth.
The ASI FlatLine™ Pulse Damper combines performance and reliability in a simple, easy-to-use housing.
Standard 10-32 inlet and outlet ports allow quick connection into virtually any HPLC system. Solid core
technology provides reliable long-term operation without the down time associated with ruptured or
leaking membrane dampers. 600–700µL internal volume at ambient pressure.
H P LC ACC E S S O R I E S
Description
FlatLine™ Pulse Damper
qty.
ea.
cat.#
25340
price
MicroPulse™ Pulse Dampers
•
•
•
•
Compact unit (2.5" x 1.5") can be placed almost anywhere.
Small, 150µL dead volume at atmospheric pressure.
PEEK™ unit can withstand pressures to 5,000psi (34,474kPa).
316 Stainless steel unit can withstand pressures to 6,000psi (41,369kPa).
Improves system baseline stability while increasing the total system volume by only 150µL. The
MicroPulse™ pulse damper is ideal for applications where minimizing the total system volume is critical.
Stainless steel and PEEK™ options for a wide range of applications.
Description
MicroPulse™ Pulse Damper, Stainless Steel
MicroPulse™ Pulse Damper, PEEK™
qty.
ea.
ea.
cat.#
25238
25239
price
LO-Pulse® Pulse Damper
LO-Pulse®
Pulse Damper Kit
The LO-Pulse® Pulse Damper is a patented, wide-dynamic-range 316 stainless steel device that smooths
pulsations and maintains constant flow at system pressures up to 6,000psi (41,369kPa). The flow path volume is only 0.9mL and the path is efficiently swept, eliminating solvent memory effects when changing
mobile phases.
The LO-Pulse® pulse damper also is available in a space-saving, economical kit that includes hardware for
mounting the pulse damper on a bracket, or for installing feet on it for bench-top use.
Description
Model LP-21 LO-Pulse® Pulse Damper
Pulse Damper Kit
cat.#
25012
25013
price
AA
Backpressure Regulators
B
Backpressure regulators can improve detector performance by preventing bubble formation in the detector flow cell. They also are useful in post-column reaction lines and between detectors and fraction collectors in preparatory work. Regulators are superior to more specific alternative solutions, like small-bore
tubing, in which pressure varies with flow rate.
B
C
C
qty.
ea.
kit
Our end-of-line and flow-through backpressure regulators are adjustable to assure constant backpressure
over a wide range of mobile-phase viscosities and flow rates. The end-of-line model is available with
1/4-28 plastic flange-type fittings or high-pressure 1/16-inch compression fittings; this design adjusts from
15 to 60psi (103 to 414kPa). The flow-through design has 1/16-inch compression fittings and is adjustable
from 7 to 75psi (48 to 517kPa).
Description
A) Backpressure Regulator: end-of-line, 1/16-inch OD tubing, flanged
B) Backpressure Regulator: end-of-line, high-pressure seat
C) Backpressure Regulator: flow-through, 5µL internal volume
Phone: 800-356-1688 or 814-353-1300
www.restek.com
qty.
ea.
ea.
ea.
cat.#
25017
25018
25020
price
Column Hardware
361
HPLC Column Tubing
Restek tubing is manufactured from fine, chromatographic-grade 316 stainless steel. It is corrosion resistant, ultrasonically cleaned and passivated. We polish the tubing and promise a burr-free cut. You can use
this tubing immediately—there is no need for any additional treatment.
2.1mm ID
cat.#
price
3.2mm ID
cat.#
price
4.6mm ID
cat.#
price
25100
25101
25102
25103
25104
25105
25106
25107
25108
25109
25110
25111
25112
25113
25114
25115
25116
25117
H P LC ACC E S S O R I E S
Length
1
/4" OD Tubing
30mm
50mm
100mm
150mm
200mm
250mm
/4-Inch HPLC Frits
1
We manufacture our frits from fine, chromatographic-grade 316 stainless steel, and we offer sizes to fit
most column and pore sizes. To choose the correct frit, check its pore size compatibility with the particle
size of the packing in the column (see chart at right). If the packing has a smaller particle size than the
pore size of the frit, the packing can clog the frit.
ID
4.6mm
4.6mm
3.2mm
3.2mm
2.1mm
2.1mm
Pore Size
2.0µm
0.5µm
2.0µm
0.5µm
2.0µm
0.5µm
qty.
10-pk.
10-pk.
10-pk.
10-pk.
10-pk.
10-pk.
cat.#
25071
25072
25073
25074
25075
25076
price
cat.#
25077
25078
price
Packing
particle size
3–4µm
5–20µm
Column End-Fittings
/4-inch end-fittings are compatible with Valco® and Parker fittings.
1
Description
Column End-Fitting for 4.6mm Column
Column End-Fitting Flat Bottom
qty.
ea.
ea.
Empty Chromatography Columns
• 316 stainless steel tubing complete with end-fittings, frits, nuts, and ferrules.
• Preassembled prior to shipment, unless otherwise requested.
• Internal 1/16-inch seats are compatible with Valco® and Parker fittings.
Length
1
/4" OD Tubing
30mm
50mm
100mm
150mm
200mm
250mm
2.1mm ID
cat.#
price
3.2mm ID
cat.#
price
4.6mm ID
cat.#
price
25118
25119
25120
25121
25122
25123
25124
25125
25126
25127
25128
25129
25130
25131
25132
25133
25134
25135
Phone: 800-356-1688 or 814-353-1300
www.restek.com
Use this
pore size:
0.5µm
2.0µm
362
Restek Pack in a Box Kit, HPLC Organizers
Restek Pack in a Box Kit
Restek’s Pack in a Box Kit is a complete column-packing system. Everything you need to pack your own
analytical HPLC columns is included: pump, reservoir, column hardware, packing material, and system
control software (computer not included). Detailed packing instructions and a DVD video also are
included. The packing pump is electric, so no pressurized air is required. AC input requirement: 85-265
VAC.
H P LC ACC E S S O R I E S
Description
Pack in a Box Kit
qty.
kit
cat.#
26408
price
HPLC Organizers*
Bill Grove
Instrument Innovations
2+ years of service!
LCLocker™ HPLC
Organizer
Deluxe BenchBooster™
Organizer
Mini pHPerch™
Storage Unit
TopLoader™ BalanceBank™
Storage Unit
HPLC 30-Column
Storage Cabinet
Book
Holders
Open Supply Bins,
13-bin unit
Glove Box
Dispensers
Description
LCLocker™
BenchBooster™
Mini pHPerch™
TopLoader™
30 Column Cabinet
Book Holder, Small
Book Holder, Large
Open Supply Bin, 4-bin Unit
Open Supply Bin, 5-bin Unit
Open Supply Bin, 13-bin Unit
Glove Box Dispenser, Single
Glove Box Dispenser, Double
Glove Box Dispenser, Triple
dimensions
24 x 12 x 6"
24 x 7 x 12"
13 x 12 x 6"
12 x 12 x 7"
173/8 x 15 x 27/8"
0.75" ID
1.5" ID
24 x 12 x 10"
12 x 16 x 10.5"
12 x 7.5 x 12"
53/8 x 111/2 x 41/2"
103/8 x 111/2 x 41/2"
153/8 x 111/2 x 41/2"
*Please note: Accessories and supplies in photographs are not included.
Phone: 800-356-1688 or 814-353-1300
www.restek.com
qty.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
ea.
cat.#
25149
25150
25147
25148
25159
25151
25152
25153
25154
25155
25156
25157
25158
price
Tech Tips
363
HPLC Pump Pressure Conversion Table
Pressure
1 psi =
1 atm =
1 kg/cm2 =
1 torr =
1 kPa =
1 bar =
1 in Hg =
psi
1
14.696
14.223
0.0193
0.1450
14.5038
0.49612
atm
0.068
1
0.967
0.00132
0.00987
0.9869
0.0334
kg/cm2
0.0703
1.0332
1
0.00136
0.0102
1.0197
0.0345
torr
51.713
760
735.5
1
7.52
751.88
25.400
kPa
6.8948
101.32
98.06
0.1330
1
100
3.376
bar
0.06895
1.0133
0.9806
0.00133
0.0100
1
0.03376
inches Hg
2.0359
29.921
28.958
0.0394
0.2962
29.5300
1
Miscible/Water Miscible Solvents
Miscible Solvents
Immiscible Solvents
Ca
rbo
nt
etr
Ch
ach
lor
ofo
lor
rm
ide
Cyc
loh
e
x
a
1,2
ne
-Di
chl
oro
Dic
hlo
eth
rom
ane
Eth
eth
yl a
a
n
c
e
eta
Eth
te
yl e
the
He
r
pta
ne
He
xan
e
Iso
oct
ane
Me
thy
l te
Me
rt-b
thy
uty
l et
l et
Pe
h
her
y
nta
l ke
ne
ton
Tol
e
uen
e
Xyl
ene
Acetone
Acetonitrile
Dimethyl formamide
Dimethyl sulfoxide
Dioxane
Ethanol
Isopropyl alcohol
Methanol
Tetrahydrofuran
Water
Benzene
Butanol
Carbon tetrachloride
Chloroform
Cyclohexane
1,2-Dichloroethane
Dichloromethane
Ethyl acetate
Ethyl ether
Heptane
Hexane
Isooctane
Methyl tert-butyl ether
Methyl ethyl ketone
Pentane
Toluene
Xylene
Ace
ton
e
Ace
ton
i
t
rile
Dim
eth
yl f
Dim
orm
eth
am
yl s
ide
Dio
ulf
xan
oxi
e
de
Eth
ano
l
Iso
pro
pyl
Me
alc
tha
oho
nol
l
Tet
rah
ydr
Wa
ofu
ter
ran
Be
nze
ne
Bu
tan
ol
Solvent Miscibility and Solubility
Phone: 800-356-1688 or 814-353-1300
www.restek.com
H P LC ACC E S S O R I E S
Multiply units in the left-most column by the conversion factors listed in the columns to the right.
e.g., 10 psi x 0.068 = 0.68atm
10 bar x 29.5300 = 295.300 inches Hg
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project