Lochinvar Copper-Fin II 402-2072, CHN0402, CHN0502, CHN0652, CHN0752, CHN0992, CHN1262, CHN1442, CHN1802, CHN2072 gas boiler Submittal Sheet
Below you will find brief information for gas boiler Copper-Fin II CHN0402, gas boiler Copper-Fin II CHN0502, gas boiler Copper-Fin II CHN0652, gas boiler Copper-Fin II CHN0752, gas boiler Copper-Fin II CHN0992, gas boiler Copper-Fin II CHN1262, gas boiler Copper-Fin II CHN1442, gas boiler Copper-Fin II CHN1802, gas boiler Copper-Fin II CHN2072. This gas boiler series operates with up to 85% thermal efficiency and its SMART SYSTEMâ„¢ operating control is equipped with a cascade sequencer for up to 8 boilers and front-end capability with Crest or Knight boilers.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
COPPER-FIN II® BOILER Submittal Sheet CHE-Sub-10b COPPER-FIN II® GAS BOILER (MODELS 402-2072) JOB NAME ______________________________________________________________________ LOCATION ______________________________________________________________________ ENGINEER_______________________________________________________________________ MECH. CONTRACTOR ___________________________________________________________ MODEL NO. _____________________________________________________________________ TYPE GAS ______________________________________________________________________ Btu/hr INPUT___________________________Btu/hr OUTPUT___________________________ NOTES Standard Features > 85% Thermal Efficiency (AHRI Certified) > Proportional Firing up to 4:1 Turndown > Hot Surface Ignition > Low NOx Operation > Sealed Combustion > Low Gas Pressure Operation > Vertical & Horizontal Venting > Category I Venting > Double Wall “B” Vent Material > Category IV Venting > AL29-4C Stainless Steel Vent Material > ASME Copper Finned Tube Heat Exchanger > ASME Certified, “H” Stamped > Gasketless design > 160 psi working pressure > On/Off Switch > Combustible Floor Rated (CH 0992 - 2072) > Adjustable High Limit w/ Manual Reset > Flow Switch > Low Air Pressure Switch > Inlet & Outlet Temperature Sensors > Easy Access Terminal Strips > Downstream Test Cocks > 50 psi ASME Relief Valve > Temperature & Pressure Gauge > 1 Year Warranty on Parts (See Warranty for Details) > 10 Year Limited Warranty (See Warranty for Details) Optional Equipment > Alarm > High & Low Gas Pressure Switches w/ Manual Reset > Cupro-Nickel Heat Exchanger > Low Water Cut Off, Probe Type w/ Manual Reset & Test > Modbus Communications > BMS Gateway - BACnet or LonWorks > Combustible Floor Kit (CH 0402-0752) > Stack Frame > Low Temperature Protection Valve > 30 psi ASME Relief Valve > 75 psi ASME Relief Valve > 100 psi ASME Relief Valve > 125 psi ASME Relief Valve > 150 psi ASME Relief Valve Smart System™ Features >SMART SYSTEM™ Operating Control > 2 Line/16 Character LCD Display > Built in Cascading Sequencer for up to 8 boilers > Front End Loading Capability with Crest or Knight Boilers > Building Management System Integration with 0-10 VDC Input > Outdoor Reset Control with Outdoor Air Sensor > Password Security > Domestic Hot Water Prioritization > Low Water Flow Control & Indication > Inlet & Outlet Temperature Readout > Freeze Protection > Service Reminder > Time Clock > 0-10 VDC Rate Output > Condensing Protection > 0-10 VDC System Pump Speed Input > Data Logging > Hours Running, Space Heating > Hours Running, Domestic Hot Water > Ignition Attempts > Last 10 Lockouts > Programmable System Efficiency Optimizers > Night Setback > Anti-Cycling > Outdoor Air Reset Curve > Boost Temperature & Time Firing Codes > M7 Firing Code - California Code > M9 Firing Code - Hot Surface Ignition with Electronic Supervision > M13 Firing Code - CSD1 / Factory Mutual / GE Gap Certifications ANSI Z21.13/CSA 4.9 certified South Coast Air Quality Management District Texas Commission on Environmental Quality > Three Pump Control > System Pump > Boiler Pump > Domestic Hot Water Pump > High Voltage Terminal Strip > 120 VAC / 60 Hertz / 1 Phase Power Supply > Pump Contacts with Pump Relay > Low Voltage Terminal Strip > 24 VAC Auxiliary Device Relay Output - Louvers > Auxiliary Proving Switch Contacts - Louvers > 3-way Valve Contacts for Low Temperature Protection > Alarm on Any Failure Contacts > 0-10 VDC System Pump Speed Contacts > Runtime Contacts > DHW Thermostat Contacts > DHW Tank Sensor Contacts > Unit Enable/Disable Contacts > System Sensor Contacts - Supply and Return > Outdoor Air Sensor Contacts > Contacts for Air Louvers > Contacts on Any Failure > Cascade Contacts > 0-10 VDC BMS External Control Contact > 0-10 VDC Rate Contacts Copper-Fin II® Gas Boiler Dimensions & Specifications E F GAS CONNECTION 0992-2072 GAS CONNECTION 0402-0752 A G INLET AIR FILTER G D OUTLET INLET H C B Copper-Fin II Heating Boiler Dimensions & Spec­i­fi­ca­tions Net AHRI Model Input Thermal Output Rating Vent Air Gas Shipping Number MBH Efficiency MBH MBH A B C D E F G H Size Inlet Conn Weight CHN0402 399 85% 339 295 31-1/2” 37-3/4” 22-1/4” 12-1/2” 7” 7” 29” 6-1/2” 6” 6” 1-1/4” 378 CHN0502 500 85% 425 370 31-1/2” 45-1/2” 22-1/4” 12-1/2” 7” 7” 29” 6-1/2” 6” 6” 1-1/4” 414 CHN0652 650 85% 553 481 31-1/2” 56-3/4” 22-1/4” 12-1/2” 8-1/2” 8-1/4” 29” 6-1/2” 8” 8” 1-1/4” 500 CHN0752 750 85% 638 555 31-1/2” 64” 22-1/4” 12-1/2” 8-1/2” 8-1/4” 29” 6-1/2” 8” 8” 1-1/4” 543 CHN0992 990 85% 842 732 36” 48-1/4” 33-1/2” 15-3/4” 8-1/2” 8-1/2” 33-3/4” 8-3/4” 10” 10” 2” 773 CHN1262 1,260 85% 1,071 931 36” 58-1/2” 33-1/2” 15-3/4” 10-1/2” 9-1/2” 33-3/4” 8-3/4” 12” 12” 2” 863 CHN1442 1,440 85% 1,224 1,064 36” 68-3/4” 33-1/2” 15-3/4” 10-1/2” 10-1/2” 33-3/4” 8-3/4” 12” 12” 2” 965 CHN1802 1,800 85% 1,530 1,330 36” 82-1/4” 33-1/2” 15-3/4” 11” 11” 33-3/4” 8-3/4” 14” 12” 2” 1,100 CHN2072 2,070 85% 1,760 1,530 36” 92-1/2” 33-1/2” 15-3/4” 11” 11” 33-3/4” 8-3/4” 14” 12” 2” 1,219 Notes: Change ‘N’ to ‘L’ for LP gas models. No deration on LP models Water connections for models CH 0402-0752 are 2” NPT on 6-1/2” centers. Header increases “B” dimension 3-1/2” for models CH 0402-0752 and 6 -1/4” for models CH 0992-2072 Water connections for models CH 0992-2072 are 2-1/2” NPT on 11-1/4” centers. Performance data is based on manufacturer test results. Venting Options Aire-LockTM Direct Vent Sealed Combustion DirectAire® Vertical DirectAire® Vertical w/ Sidewall Inlet Outdoor Installation Power DirectAire® Horizontal Powered Side Wall Sidewall Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 6/15—Printed in U.S.A.
advertisement
Key Features
- 85% Thermal Efficiency
- Proportional Firing up to 4:1 Turndown
- SMART SYSTEMâ„¢ Operating Control
- ASME Copper Finned Tube Heat Exchanger
- Vertical & Horizontal Venting
- Sealed Combustion
- Low NOx Operation
- Category I & IV Venting
- Combustible Floor Rated