267 3 us~v~Specification Sheet

267 3 us~v~Specification Sheet
HEAT RECOVERY VENTILATOR
Venmar AVS HRV EKO 1.5
Part no. 43901
80 to 157 CFM (0.4 in. w.g.)
66 to 132 CFM (0.4 in. w.g.)
53 to 106 CFM (0.4 in. w.g.)
40 to 80 CFM (0.4 in. w.g.)
Controls
This unit is very simple to operate. Once it is installed,
press on its push button, located under the unit, to activate
it. Press once for low speed, once again for high speed, and
once more to stop it
The following main controls are available:
- Altitude programmable digital control
with Smart mode
- Deco-Touch digital control
no. 40440
no. 40395
Also, one to 5 of the following optional controls can be
added:
- 20/40/60-min. Push-Button Timer
no. 03364
- 60-min. Mechanical Timer
no. 00910
Options
Complete line of registers and diffusers
Electric duct heater
VB0122
DISCOVER THE NEW GENERATION OF
VENMAR AIR EXCHANGERS: ULTRA-EFFICIENT
AND ENVIRONMENTALLY-FRIENDLY
The AVS HRV EKO 1.5 has been designed to be one of the
most eco-friendly HRV air exchangers on the market. Its
innovative design incorporates extremely high performance
ECM* motors, which enable EKO to significantly lower energy
costs without affecting its performance. Additional energy
efficiency is found through its advanced heat recovery core,
which can retain up to 80% of home’s heating. EKO
surpasses energy-saving standards while providing effective
heat recovery, ventilation and quiet operation. All aspects
have been designed to facilitate balancing of air flow and
simplify uses and installation.
High performance ECM* motors
Faster and easier installation of insulated flexible ducts
with practical straps
Integrated balancing dampers
Integrated electronic board on motors
Homeshield™ defrosting system
Heat recovery core with superior capacity
Optimized drainage system
ENERGY STAR® qualified
REPAIRS AND MAINTENANCE
The AVS HRV EKO 1.5 high output ECM* motors are
permanently lubricated. The electronic circuit board eliminates
electromechanical parts, reducing repair time to a minimum.
Homeshield™ Defrosting System
The AVS HRV EKO 1.5 uses a unique defrosting method. No
negative pressure is created by air exhausted to the outside,
as the air is recirculated into the house, helping to prevent
any backdraft.
STALE AIR
FROM BUILDING
FILTERED
AIR
TO BUILDING
OUTSIDE
TEMPERATURE
ºC
WARMER
THAN -5
VF0046
ºF
WARMER
THAN 23
-5 TO -27 23 TO -17
-27
-17
& LESS
& LESS
DEFROST CYCLE
DEFROSTING MIN./
OPERATING MIN.
NO
DEFROST
7/25
10/22
Heat Recovery Core
Dimensions: 10” x 10” x 14.25” (25.4 cm x 25.4 cm x 36.2 cm)
Exchange surface: 110 ft² (10.2 m²)
Weight: 7.36 lb (3.3 kg)
Material: Polypropylene
Type: Cross Flow
Warranty: Limited lifetime
WARRANTY
The AVS HRV EKO 1.5 unit is protected by a complete 5-year
warranty on all parts. The heat recovery core is covered by a
limited lifetime warranty, with the original proof of purchase.
*Electronically Commutated Motor.
Available at:
Requirements and Standards
Complies with the UL 1812 requirements regulating the
installation of Heat Recovery Ventilators
Complies with the CSA C22.2 no. 113 Standard applicable
to ventilators
Complies with CSA C444 requirements regulating the
installation of Heat Recovery Ventilators
Technical data was obtained from published results of tests
relating to CSA C439 Standards
HVI certified and ENERGY STAR® qualified
Dimensions and Service Clearances: Venmar AVS HRV EKO 1.5
23 9/16”
(599 mm)
2 ¹/16”
(53 mm)
3 13/16”
(97 mm)
24 9/16”
(624 mm)
1
POWER
CORD 3’
22 ½”
(572 mm)
3
7 7/16”
(189 mm)
4
2
14 1/16”
(358 mm)
NOTE: Every port fits 6” round duct.
18 ¼”
(464 mm)
1: EXHAUST AIR TO OUTSIDE
2: FRESH AIR FROM OUTSIDE
3: EXHAUST AIR FROM BUILDING
4: FRESH AIR TO BUILDING
14 15/16”
(380 mm)
VK0066A
Ventilation Performance
NET SUPPLY
AIR FLOW
CFM M³/H
L/ S
89 189 320
83 177 299
79 167 284
74 156 266
69 147 248
64 136 230
59 126 212
54 115 194
47 110 169
40 86 144
35 74 126
L/ S
89
84
79
74
69
64
60
54
47
41
35
GROSS AIR FLOW
SUPPLY
EXHAUST
CFM M³/H L/S
CFM M³/H
190 320 87 185 313
179 302 83 177 299
169 284 79 167 284
158 266 73 155 263
148 248 68 146 245
137 230 63 133 227
127 216 58 123 209
116 194 51 108 184
101 169 45 96 162
87 148 38 80 137
75 126 31 65 112
1.2
EXTERNAL STATIC PRESSURE
IN. W.G. (PA = N X 248.36)
EXT. STATIC
PRESSURE
PA IN. W.G.
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
250
1.0
275
1.1
SUPPLY (CFM)
1.0
EXHAUST (CFM)
0.8
0.6
0.4
0.2
4
0.0
0
25
50
VG0083A
CFM
Energy Performance
SUPPLY
NET
POWER
SENSIBLE
APPARENT LATENT/RECOVERY
SENSIBLE
MOISTURE
TEMPERATURE AIR FLOW CONSUMED RECOVERY
WATTS EFFICIENCY EFFECTIVENESS TRANSFER
ºC
ºF
L /S CFM
HEATING
0
32 23 49
24
75
83
0.01
0
32 30 64
26
74
80
0.01
0
32 38 81
32
73
78
0.01
0
32 57 122
54
67
72
0.01
-25 -13 29 61
40
64
89
0.02
75
3
100
1
2
125
150
GROSS AIR FLOW
(L/S = CFM X 0.4719) (M³/H = L/S
SPEED
SPEED
SPEED
SPEED
RANGE*
RANGE*
RANGE*
RANGE*
*AT 0.4
1: 80 TO
2: 66 TO
3: 53 TO
4: 40 TO
X
175 200
3.6)
157 CFM
132 CFM
106 CFM
80 CFM
IN. W.G.
NOTE: All specifications are subject to change without notice.
Specifications and Ratings
Model: AVS HRV EKO 1.5
Part number: 43901
Total assembled weight (including
polypropylene core): 52.4 lb (23.8 kg)
Oval shaped ports; fit 6” round ducts
Drains:1/2” (1.2 cm) fittings with
10 ft (3 m) PVC drain
Core filters: 2 washable Merv 9
9.2” x 14.25” x 3.8”
(23.4 cm x 36.2 cm x 9.6 cm)
PROJECT:
LOCATION:
MODEL
Housing: Pre-painted steel
Heat recovery core:
Insulation: Expanded polystyrene
- Heat exchange surface area:
110 ft² (10.2 m²)
Mounting: Suspension by chains and springs
Supply & Exhaust blower motors:
- Type: Cross flow
2 ECM motors
- Material: Polypropylene
- Protection type: Thermally protected
Unit electrical characteristics:
- Insulation class: B
Volts Frequency Amperes
Speed control on unit:
120
60 Hz
1.3
- Low and high speed.
- Other modes available with Altitude or
Deco-Touch main control.
Watts
98
REMARKS
NO.:
QTY.:
SUBMITTED
BY:
DATE:
Residential Product Group, 550 Lemire Blvd., Drummondville, QC, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715
www.venmar.ca
12/03
PRODUCT SHEET NO. 91414