Universal Tool UT8961 Lever Start Auto Shut-Off Angle Screwdriver User manual

Universal Tool UT8961 Lever Start Auto Shut-Off Angle Screwdriver User manual

Below you will find brief information for Angle Screwdriver UT8961 Lever Start Auto Shut-Off. This device is designed for operation at air pressure of 90 pounds per square inch, and includes features such as rear exhaust, rugged steel angle head, thumb operated reverse switch and built-in suspension bail.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Angle Screwdriver UT8961 Lever Start Auto Shut-Off User Manual | Manualzz

PLEASE READ AND FOLLOW ALL WARNINGS

Read Operating Instructions

Always become familiar with all the instructions and warnings before operating any power tool.

Always Wear Approved

Eye Protection

Impact resistant eye protection should meet or exceed the standards as set forth in the United

States ANSI Z87.1, Occupational and Educational Eye and Face

Protection. Look for the marking

Z87.1 on your eye protection to insure that it is an approved style.

For further information, ANSI Z87.1,

Occupational and Educational Eye and Face Protection, is available from the American National

Standards Institute, Inc., 11 West

42nd Street, New York, NY 10036.

Hearing Protection is

Recommended

Hearing protection should be used when the noise level exposure equals or exceeds an 8 hour timeweighted average sound level of 85 dBA. Process noise, reflective surfaces, other tools being operated nearby, all add to the noise level present in your work area. If you are unable to determine your noise level exposure, we recommend the use of hearing protection.

Avoid Prolonged Exposure to

Vibration

Tools can vibrate during use.

Prolonged exposure to vibration or very repetitive hand and arm movements, can cause injury. Stop using any tool if discomfort, tingling feeling or pain occurs. You should consult your physician before resuming use of the tool.

90 PSIG Maximum

This tool is designed to operate at an air pressure of 90 pounds per square inch gauge pressure (90

PSIG) maximum, at the tool. Use of higher air pressure can, and may cause injury. Also, the use of higher air pressure places the internal components under loads and stresses they were not designed for, causing premature failure. The air supply should be clean and dry, preferably lubricated. For best results, drain the moisture from your compressor daily.

WARNING:

Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known to cause cancer, birth defects or reproductive harm. Some examples of these chemicals are:

Lead from lead-based paints

Crystalline silica from bricks, cement and other masonry products

Arsenic and chromium from chemically treated lumber

Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals, work in a well-ventilated area and work with approved safety equipment such as those dust masks that are specially designed to filter out microscopic particles.

Universal Tool a Division of Florida Pneumatic Manufacturing Corporation

851 Jupiter Park Lane, Jupiter, Florida 33458

Toll Free 1-800-327-9403

UT8961-1 Lever Start

Auto Shut-Off Angle Screwdriver

Safety Instructions

The following instructions are furnished as general guidelines for use of your pneumatic tool. They cannot comprehensively cover all possible or conceivable uses of the subject tool.

For additional information on the safe use of air tools, we advise you to obtain a copy of CAGI B186.1-2009

Safety Code for Portable Air Tools, available from the following source:

COMPRESSED AIR AND GAS INSTITUTE

1300 Sumner Avenue

Cleveland, OH 44115-2851

Ph: 216-241-7333 www.cagi.org OR from

Florida Pneumatic Manufacturing Corp.

851 Jupiter Park Lane

Jupiter, FL 33458

561-744-9500 www.florida-pneumatic.com

The use of the word “shall” in the following instructions, indicates that adherence to the particular requirement is necessary to conform to CAGI

B186.1-2009.

Tool Application and Usage

Portable tools shall be used only for the purposes intended in their design and within the capacity for which they were intended and rated. It shall be the tool owner’s and/or employer’s responsibility to instruct each operator in the safe use of the tool. Tools shall not be used without guards and safety devices as furnished by the manufacturer. Where an air tool is modified or altered, the modifier shall provide the safeguards to enable it to be safely used in the operations intended and to comply with any applicable provisions as contained in CAGI B186.1-2009 .

condition.

Tool Installation

Pressure regulators shall be used to limit air pressure to the rated pressure where the supply pressure exceeds the tool’s rated pressure. Air hoses and lines shall be relieved of compressed air before being disconnected or disjointed, unless there is automatic valve closing protection at the joint being separated. Synthetic lubricants which can cause deterioration of elastomer seals shall not be used in air systems of air tools.

It shall be the tool owner’s and/or employer’s responsibility to assure that tools are maintained in a safe operating condition. Tool maintenance and repair shall be performed by authorized, trained, competent personnel. Tools shall be disconnected from their are attempted. Repairs shall be consistent with the manufacturer’s recommended procedures. Tool, hoses and fittings shall be replaced if unsuitable for safe operation. It shall be the tool owner’s and/or employer’s responsibility to keep required rating markings and warnings on the tool in legible

Read these instructions carefully before attempting to install, operate or service this Florida Pneumatic product. Failure to comply with the instructions could result in personal injury and/or property damage!

Retain these instructions for future reference.

FPMC

Universal Tool warrants its tools to be free from defects in material and workmanship for one year from the date of purchase. This warranty does not apply to tools which have been abused, misused, modified or repaired by someone other than Universal Tool or its authorized service centers. If a Universal Tool proves defective in material of workmanship within one year after purchase, return it to any authorized service center or to Universal Tool, freight prepaid. Please enclose your name, address and adequate proof of purchase date with a brief description of the defect. Universal Tool will, at its option, repair or replace defective tools, free of charge. Repairs or replacements are warranted as described above for the remainder of the warranty period. Universal Tool's sole liability and your exclusive remedy under this warranty is limited to repair or replacement of the defective tool. There are no other warranties expressed or implied and Universal Tool shall not be liable for incidental, consequential or special damages, or any other damages, costs or expense of repair or replacement as described above.

Specifications

Free Speed

Torque range

Motor

Drive Size

Exhaust

Weight

Length

Air Consp.

300 RPM

26-160

0.5 HP

1/4” Int. Hex

Rear

2.6 lbs.

13.1 in.

4.0 CFM

advertisement

Key Features

  • Auto Shut-Off
  • Lever Start
  • Rugged Steel Angle Head
  • Thumb operated reverse switch
  • Built-in suspension bail
  • Easy-to-adjust clutch

Frequently Answers and Questions

What is the maximum air pressure this tool can handle?
The maximum air pressure for this tool is 90 pounds per square inch gauge pressure (90 PSIG).
What type of air supply should I use with this tool?
The air supply should be clean and dry, preferably lubricated. For best results, drain the moisture from your compressor daily.
What are some safety precautions I should take when using this tool?
Always wear approved eye protection, hearing protection is recommended, avoid prolonged exposure to vibration, and follow all safety instructions provided in the manual.