Vernier Logger Pro 3 manual

Vernier Logger Pro 3 manual

Vernier Logger Pro 3 is a powerful and easy-to-use data acquisition and analysis software. It allows you to collect data from a variety of sensors, including temperature, light, sound, and motion sensors. Logger Pro 3 also includes a number of powerful analysis tools, such as graphing, statistics, and curve fitting. With Logger Pro 3, you can easily collect, analyze, and share your data.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Vernier Logger Pro 3 manual | Manualzz

Quick RefeRence Manual

ii

TaBle Of cOnTenTS

This guide first leads you through the basics of Logger Pro, including software installation procedures. You will learn how to collect data, manually enter data, and import data from Texas Instruments and Palm handhelds.

From there, you will learn about the more advanced features of Logger Pro.

Getting Started

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

introduction

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Tutorials

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

acquiring Data

Collect Data

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Manual Data Entry

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Import Data

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Remote Data .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Toolbar Guide

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

finding Your Way around logger Pro

Logger Pro Toolbar and Pages

. . . . . . . . . . . . . . . . . . . . .

10

The Sensors Dialog

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Managing Your Page and Data .

. . . . . . . . . . . . . . . . . . . .

11

Analyze Data

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

Printing

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Where to Next?

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14 iii

iv

GeTTinG STaRTeD logger Pro Requirements

To use Logger Pro, you will need a Windows or

Macintosh computer. See www.vernier.com/lp for detailed system requirements. For data collection you will need a data source such as a LabQuest, LabPro or Go! Link with a Vernier sensor, or a Go! Motion or

Go! Temp. Other compatible data sources are listed at www.vernier.com/lp

Note: Logger Pro cannot be used with the ULI or

Serial Box interface. Contact us for the availability of earlier versions of Logger Pro for older operating systems or interfaces.

load logger Pro

Windows

 Place the Logger Pro CD in the

CD-ROM drive of your computer.

 If you have Autorun enabled, the installation will launch automatically; otherwise launch Setup.exe from the CD.

 The Logger Pro installer will start, and a series of dialog boxes will step you through the installation of the Logger Pro software. We recommend that you accept the default directory.

Macintosh

 Place the Logger Pro CD in the CD-ROM drive of your computer and double-click on the CD icon.

 Double-click the “Install Logger Pro” icon and follow the instructions.

Get everything Ready

To collect data with Logger Pro you will need either a

LabPro ® or a Go!

® Link, with at least one sensor, or one of several dedicated sensors listed below.

a Vernier labQuest interface:

The Vernier LabQuest is a color touch-screen data-collection interface.

It connects to your computer with its included USB cable.

a Vernier labPro interface:

The Vernier LabPro is a multi-channel interface with its power supply and USB or serial cable.

a Go! link interface:

Go! Link is a single-channel interface that connects directly to a computer’s USB port.

1

2

and, at least one sensor:

Sensors are connected to the LabPro or Go! Link.

A Stainless Steel Temperature Probe is a good choice for initial testing of Logger Pro. The Voltage

Probe included with the LabPro interface can also be used.

Or, Go! Temp

The Vernier Go!Temp is a temperature probe that connects directly to the USB port of your computer. No interface is needed. This sensor comes with the

Logger Lite software.

Or, Go! Motion

The Go! Motion is a motion detector that connects directly to a computer’s

USB port.

Or, WDSS

The Wireless Dynamics Sensor System collects acceleration, force, and altitude data. It requires a Bluetoothequipped computer.

Or, Spectrometer

The Vernier Spectrometer measures intensity and absorbance over many wavelengths simultaneously.

Or, Garmin GPS

Select Garmin GPS units can connect to Logger Pro for live data collection, or the retrieval of stored tracks or waypoints.

Or, Ohaus Balances

Logger Pro allows you to collect mass data from select models of

Ohaus balances.

initial Setup

Note: The following setup instructions are for the

LabPro interface. They are similar to the LabQuest and Go! Link interface instructions. Choose Logger

Pro 3 Help from the Help menu for further details.

The LabQuest Quick Start Guide contains information specifi c to LabQuest.

Before launching logger Pro, you should:

 Power the LabPro using the AC power supply or AA batteries.

 Connect a sensor to LabPro.

 Connect the USB or serial cable to LabPro.

 Attach the other end of the interface cable to any unused serial port or USB port on your computer.

Start logger Pro

Locate the Logger Pro icon and double-click on it.

Mac OS X users can fi nd the icon in the Logger Pro folder created in Applications during installation.

Note: The fi rst time that you run Logger Pro with your LabPro interface, a message may appear notifying you of an update to the LabPro operating system. Do not interrupt this update.

Logger Pro can collect data from multiple interfaces and devices. If Logger Pro has successfully detected these devices, you will see the device icon (see fi gure below). Also, if an auto-ID sensor is attached, the current sensor reading will appear below the toolbar

(as shown in the fi gure). Some devices, such as WDSS,

GPS or Ohaus balances, require manual connection in

Logger Pro. Choose Connect Interface  (device name) from the Experiment menu to connect.

In the fi gure above, a Go!Link, Go!Temp, LabPro and Ohaus balance are connected to the computer.

You have now successfully set up your equipment and installed Logger Pro. Keep reading for instructions on the various ways to collect and obtain data. You will also learn how to use Logger Pro’s powerful features, such as data analysis, movies, and customizing your experiments.

3

4

inTRODucTiOn

Logger Pro is a program that allows you to collect and analyze data from Vernier LabQuest, LabPro,

Go! Link, Go!Temp, Go! Motion, Vernier/Ocean Optics

Spectrometers, the Vernier WDSS, and Ohaus balances.

Among its many features, data may be manually entered from the keyboard, pasted from the clipboard, or retrieved from a file saved on disk. Logger Pro is also a document creator, with the ability to include several pages in one document With Logger Pro you can also:

 Perform data analysis, such as statistical analysis, curve fitting, and calculated columns.

 Add pictures to lab reports.

 Add movies and synchronize movies with data collection.

 Import data collected with TI handhelds.

 Import data collected with Palm OS ® handhelds.

 Manually enter data.

 Export data to Excel ® or other spreadsheets.

 Have students draw a prediction on a graph and see how well the experimental data matches it.

 Use video analysis to create a graphical representation of the motion you see in a movie.

 Use video capture to record video streaming from digital camera or webcam.

The Help guide in the program provides complete details about Logger Pro. Tutorials are also included. Select

Open from the File menu to access them.

TuTORialS

There are tutorials that cover many Logger Pro features and menus. To access, choose Open from the File menu, then open the Tutorials folder:

 Getting Started

 Stats, Tangents,

Integrals

 Motion Measurement

 Linearization

(Parts 1 and 2)

 Events with Entry  Manual Data Entry

 Curve Fitting  Video Analysis

All you need to do is open the tutorial fi le you want to try out, and then follow the on-screen instructions in that fi le.

The extensive Help in logger Pro provides detailed instructions for use of the program.

The answer you are looking for may be just a mouse click or two away!

acQuiRinG DaTa

You can acquire data in Logger Pro by collecting data from a source, importing from a compatible device, or manually entering data from the keyboard.

collect Data

Before collecting data, perform the Initial Setup steps for your interface. These steps are outlined on page 3 of this guide.

confi gure logger Pro for Your experiment

There are several ways to set up Logger Pro for an experiment. Most are automatic.

Auto-ID Sensors With auto-ID sensors, all you need to do is connect the sensor to one of the

LabPro channels and start Logger Pro software. The sensor will be identifi ed, and default data-collection parameters loaded for that sensor. You are ready to click the button and begin data collection!

Probes & sensors experiment fi les If you are using an older Vernier sensor that is not auto-ID, or if you want to use some other specially confi gured fi le, you will need the Probes & Sensors folder.

Choose Open from the File menu, and open the

Probes & Sensor folder. There you will fi nd a folder

5

6 for each of the Vernier sensors. Open up a fi le with a name that best fi ts the data collection you want to perform.

Vernier lab book experiment fi les When you choose Open from the File menu, you will see a series of folders with Vernier lab book experiment fi les, such as Biology with Computers, etc. Each of these folders contains 30-40 experiment fi les, each corresponding to an experiment in each of our lab books.

Sensor dialog This dialog, called by clicking the respective button in the toolbar ( , for example) shows your sensor information, the units and current readings. If an auto-ID sensor is connected, Logger Pro will identify the sensors connected. Or, if your sensor is not auto-ID, you can simply drag the sensor to the appropriate channel.

now You are Ready to collect Data

Click . Logger Pro will begin plotting data in the graph window. Tip: Normally, the data collection stops at the time indicated on the time axis. You can stop the data collection early by clicking . If you discover you want the data collection to go even longer, you can add additional time by choosing Extend Collection from the

Experiment menu.

Now that you have collected data, there are many things you can do with it. Keep reading for descriptions of some of the most commonly-used Logger Pro features.

Store Data

The Store Latest Run option in the Experiment menu saves the most recently collected data in memory, allowing you to do another collection without losing the first one.

The run labeled “Latest” always contains the most recently collected data, and is overwritten when you collect more data. When you store the latest run, a new data set named Run 1, Run 2, etc, is created and the values of the latest data set are copied to it. Columns in the latest data set are drawn with thick lines on the graph, while other columns are drawn with thin lines.

Note: Using Store Latest Run does not save data on disk, nor will it preserve your data between sessions or when you turn off your computer. You must select Save

As from the File menu to save your session (data and analysis) to disk.

Data collection and Modes

You are not limited to time-based data collection.

Choose Data Collection from the Experiment menu to modify data collection parameters for your experiment. See Logger

Pro’s Help for information about your choices.

Time Based Set the data collection rate as a function of time.

Events With Entry A data point is recorded whenever the Keep button is clicked. You are then prompted to enter values for a new data column.

Selected Events A data point is recorded whenever the

Keep button is clicked.

Digital Events You can set data collection to run continuously (until the Stop button is clicked) or at a certain number of events.

7

Manual Data entry

You can type data directly into the data table from the keyboard. To manually enter data, disconnect all interfaces, and start Logger

Pro. Click on a cell and type in a number. You can use the mouse or the Enter/Return key to move and edit within the table. Your values will also be plotted on the graph.

8

import Data

 You can import data from a LabQuest. After collecting data on the LabQuest, connect it to your computer using its included USB cable, and start

Logger Pro. Follow the prompts that you see in

Logger Pro.

 You can import data from

Texas Instruments graphing calculators, LabPro, or CBL 2 devices using the TI Connectivity

Cable. Do so by choosing Import

From  TI Device from the File menu or clicking the button.

The dialog box to the right will appear with the available data lists for importing.

 Data collected and stored in the LabPro interface using its Quick Setup feature can be imported via the serial or USB cable. Do so by choosing Import

From  LabPro from the File menu.

 Data collected with a Palm

OS handheld running the

Vernier Data Pro program can be imported by fi rst starting up Logger Pro, placing the Palm OS handheld into its HotSync ® cradle, and pressing the HotSync button. Data are then displayed in the table and graph of Logger

Pro, where you can print or do further analysis.

Remote Data

LabQuest, LabPro, Go! Motion and WDSS can collect data without a computer attached. You can use

Logger Pro to set up the experiment, detach the device, collect data remotely, then reattach the device to the computer to retrieve the data. Select Remote  Setup from the Experiment menu to set up LabQuest, LabPro,

Go! Motion or WDSS for remote data collection.

click To

Create a new document.

Open an existing document.

Save the active document or template with its current name.

Print the screen as displayed on your monitor.

TOOlBaR GuiDe

click To

Enter Tangent Line mode.

Integrate selected data range.

Calculate statistics on selected data.

Make a linear fi t to the selected range.

Perform general curve fi ts.

Scroll between pages.

Bring up the previous page of the current document.

Bring up the next page of the current document.

Bring up the Data Browser Window.

Import data from the Texas Instruments calculator.

Automatically scale the graph to include all data points.

Zoom in to the selected region of the graph.

Zoom out by a factor of two in both x- and y-directions.

Enter Examine mode.

Set data-collection parameters.

Begin collecting data.

(The following icons only appear when collecting data or if relevant.)

Stops collecting data or stops a replay.

Tells the heat pulser to generate a pulse.

Click this button to keep a data point.

Click the Zero button to set the current value of a sensor to zero.

Create a new Graph Match.

9

finD YOuR WaY aROunD logger Pro

Take a few moments to get familiar with Logger

Pro’s layout.

logger Pro Screen and Toolbar

Toolbar The toolbar contains buttons for the most commonly used features of Logger Pro. All of the features in the toolbar are also available in the menus.

As you move the pointer across a button, you are given a short description of each feature. (See the Toolbar

Guide on page 9).

Menu bar Logger Pro has a menu bar across the top of the main window. Use the menu bar to access all of the software’s features.

Object You can add new objects using the items in the

Insert menu and modify them using the Options menu or by double-clicking on the objects. Some objects are listed here:

Graph Available graphs include Cartesian, Histogram,

FFT Graph.

Table Displays data in data sets.

Text A small text editor. Use it to record notes for your fi le.

10

Text Annotation Allows you to enter and edit notes about the data. Text annotations are part of graphs.

Meter Displays the values of data columns in large digits, as a thermometer, gauge, or animated display.

Movie You can add a movie of an experiment to your page, then synchronize data collection to the movie.

Picture You can add a digital picture object to your page.

navigate Between Pages

Logger Pro 3 has “pages.” These pages allow you to have different layouts of data in a single fi le. One page might contain a graph and table with fi ve different data collections. On different pages you might perform comparisons between different collections or just go into each collection in more detail.

Click on the Toolbar to jump to the next page.

Click on the Toolbar to jump to the previous page.

You can also use the drop-down menu from the

Toolbar to choose a page directly.

The Sensors Dialog

interface in the toolbar ( , for example) shows your sensor information, the units and current readings.

The details of the dialog vary, depending on the use of LabQuest, LabPro, Go!Temp, Go! Link, Go! Motion,

WDSS, spectrometers, GPS or Ohaus balances.

Use the scroll bars in the Sensor Catalogs to view all sensors.

By clicking in a Channel box with a displayed sensor, you may be able to:

Calibrate a sensor Perform a new calibration.

Get sensor information Includes collection details and calibration information.

Zero a sensor Sets the current reading of a sensor to zero.

Choose sensor Select another sensor for the channel.

Change the current settings Select the available units or calibration settings

Analog out (CH 4 only) This channel can be used as a function generator.

Remove sensor Clears the channel of the sensor.

Manage Your Page and Data

There are numerous ways that you can customize the presentation of your data.

Manage and adjust Objects

Move Objects Select the object by clicking on it once. Move the cursor over the edge of the selected object until the cursor turns into a hand, then hold down the mouse button while grabbing and moving the object.

Resize Objects Single-click on an object to select it. When an object is selected, its border becomes visible, along with eight resizing handles.

Clicking and dragging a resize handle will resize the object in the appropriate direction.

11

Graph Axes Customize your graph by changing the columns that are displayed.

1. Position the mouse over the X-axis or Y-axis label and click. A list of available columns will appear.

2. Select the column you want displayed. If you want more than one column displayed, select More and check the boxes next to the desired columns.

Graph Options Doubleclick on the graph or select

Graph Options from the

Options menu to call up the

Graph Options dialog. This allows you to change the graph object appearance, including point protectors, legend, line style, and other graph features. Click the Axis Options Tab to adjust scaling and select what columns are plotted or add a Y axis to the right-hand side of the graph.

create a column

You can create a new column that is manually entered or that consists of calculations based on other data in Logger

Pro. Create a new column by selecting New Manual Column or New Calculated Column from the Data menu.

12

Select and edit cells in a Data Table

Manually-entered data and data collected using the

Events with Entry mode can be edited.

 To edit a single cell in a table, single-click in the cell.

 To select a single cell in a table, click and drag the selection within that cell.

 You can select entire columns by clicking on the title of the column.

 You can select an entire row of data by clicking on the row numbers.

The Data Browser

The Data Browser is a container for all data in a Logger Pro file. In contrast, a given Data Table will not necessarily show all data columns.

Data Browser Features

Drag and drop from the

Data Browser to objects such as tables and graphs.

Drag a column to a y- or x-axis to plot it there.

When the Data Browser is selected, edit menu items like Cut, Copy, Paste, etc. will apply to the selected items within the Data Browser.

Incorporate videos and synchronize them with data you have collected! We have included more than 40 videos, but you can easily use your own.

analyze Data

The Analyze menu contains functions for examining and analyzing your data. A few of the most commonly used analysis functions include:

Examine Shows the x- and y-values of the data point closest to the mouse pointer.

Statistics Calculates the minimum, maximum, mean, and standard deviation.

Curve Fit Fits a selected or user-defined function over the data.

Draw Prediction Sketch a prediction on a graph using the mouse.

Several of the analysis features are available from the Toolbar.

additional analysis features

Movie You can synchronize data collection and a movie of the experiment so that as you Replay the movie, the data are replayed on the graph.

Video Analysis You can create a graphical representation of the motion you see in a movie.

Model Perform a manual curve fit of your data.

Histogram Displays the distribution of values for a data set in bar graph format.

Strip Chart Each new collected data point gets added to the right most edge of the graph.

FFT Gives the amplitudes of the frequency components of a data series, and displays a bar graph showing the amplitudes of the frequencies shown along the x-axis.

13

Set Preferences

The Preferences dialog box contains several options that pertain to the general operation of the software. These preferences will apply every time Logger Pro is launched.

In Windows, choose Preferences from the

File menu. In Mac OS X, choose Preferences from the

Logger Pro menu.

Printing

Print Graphs and Data

1. Arrange the objects on the screen as you want them to appear on the paper. If you choose, you can print several graphs and data tables at once.

2. Select Print from the File menu or click the toolbar. on

3. When the printer is ready, click

Print dialog box.

in the

You can print the graphs and data tables individually by selecting Print Graph or Print Data Table from the

File menu.

Where to next?

The extensive Help system in Logger Pro provides detailed instructions for these and other features.

Also available are the Logger Pro Tutorials. Choose

Open from the File menu to access them. These short tutorials are suitable for reference or for use in your classes. First-time users should work through one introductory tutorial and the advanced tutorials as needed.

If you have questions as you are using our software, call or e-mail us. We will be happy to help!

14

Vernier Software & Technology

13979 SW Millikan Way

Beaverton, OR 97005-2886

toll free 888.837.6437 | fax 503.277.2440 www.vernier.com

15

nOTeS

16

LabQuest, Logger Pro 3, Go! and Vernier LabPro are registered trademarks of Vernier Software & Technology in the United

States of America. Windows and Excel are registered trademarks of Microsoft Corporation. Quicktime and the Quicktime logo are trademarks or registered trademarks of Apple Computer, Inc., and are used under license therefrom. Macintosh and Mac OS are registered trademarks of Apple Computer, Inc. Palm OS and HotSync are registered Trademarks of Palm, Inc.

advertisement

Key Features

  • Collect data from a variety of sensors
  • Easy-to-use interface
  • Powerful analysis tools
  • Share your data easily

Frequently Answers and Questions

How do I connect my sensor to Logger Pro 3?
To connect your sensor to Logger Pro 3, simply plug the sensor into one of the LabPro channels.
How do I start collecting data?
To start collecting data, click on the Collect button in the toolbar.
How do I analyze my data?
To analyze your data, you can use the graphing, statistics, and curve fitting tools in Logger Pro 3.

Related manuals

Download PDF

advertisement