ANOLIS ArcPower 36/K2 LED driver User manual
Below you will find brief information for LED driver ArcPower 36/K2. The ArcPower 36/K2 is a high-performance LED driver that can be used to control up to 36 K2 LED modules in RGB mode or 42 K2 LED modules in RGBW mode. This driver can operate in DMX mode, stand-alone mode or master/slave mode and can be controlled using either DMX 512 or DyNet protocol. The ArcPower 36/K2 also features 10 built-in programs and 3 user-editable programs. You can use this driver to create a variety of dynamic lighting effects for your events.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
version 1.3 ArcPower 36/K2 Table of contents 1. Safety instructions.......................................................................................................... 3 2. Operating determinations............................................................................................... 3 3.Description of the ArcPower 36/K2................................................................................ 4 4.Installation........................................................................................................................ 4 4.1.Connection to the mains............................................................................................. 4 4.2.Mounting the ArcPower 36/K2.................................................................................... 5 4.3.Conection cables......................................................................................................... 5 5.Installing instructions...................................................................................................... 6 5.1.DMX operating............................................................................................................ 6 5.2.Master-slave operating................................................................................................ 8 5.3. Operating via DyNet protocol..................................................................................... 9 6.ArcPower 36/K2 - Control menu map........................................................................... 11 7.ArcPower 36/K2 - DMX protocol................................................................................... 12 8.Control board.................................................................................................................. 13 8.1 Addressing the ArcPower 36/K2 .............................................................................. 13 8.2 Program running....................................................................................................... 13 8.3 Manual mode............................................................................................................ 14 8.4 Test sequences......................................................................................................... 15 8.5 Stand-alone mode..................................................................................................... 15 8.6 Special functions....................................................................................................... 15 9.Control of the ArcPower 36/K2 via RS-232.................................................................. 18 9.1Wiring an RS-232 serial port ..................................................................................... 18 9.2 Selecting a zone........................................................................................................ 18 9.3 Setting a serial port of PC......................................................................................... 18 9.4 Zone commands....................................................................................................... 18 10.Technical Specifications:............................................................................................ 20 11. Replacing the fuse ..................................................................................................... 21 CAUTION! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this product has to: - be qualilfied - follow the instructions of this manual CAUTION! Be careful with your operations. With a high voltage you can suffer a dangerous electric shock when touching the wires inside the unit! This product has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual. To prevent from danger of accident ,the device has to be fixed on flat, non-f lammable surface in compliance with the installing instruction included in this manual. Important: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the product. Always ground the unit. The electric connection, repairs and servicing must be carried out by a qualified employee. Do not connect this unit to a dimmer pack. Use a source of AC power that complies with local building and electrical rules.AC power has to have both overload and short circuit protection 2. Operating determinations This product was designed for indoor use with K2 Luxeon LEDs modules only.In case of connecting 1W LEDs modules these modules will be destroyed! If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature. Avoid brute force when installing or operating the unit. When choosing the installation-spot, please make sure that the unit is not exposed to extreme heat, moisture or dust. Only operate the unit after having checked that the housing is firmly closed and all screws are tightly fastened. The maximum ambient temperature 40° C must never be exceeded. Operate the unit only after having familiarized with its functions. Do not permit operation by persons not qualified for operating the unit. Most damages are the result of unprofessional operation! Please use the original packaging if the product is to be transported. Please consider that unauthorized modifications on the unit are forbidden due to safety reasons! 3.Description of the ArcPower 36/K2 1 - Power Indicator 2 - Control board 3 - DMX Output 4 - DMX Input 5 - LED Input 6 - RS232 input 7 - Fuse holder 8 - Power cord DMX Input,Output LED module Input RJ45 socket Front view of the socket: Pin 1: Not connected Pin 2: +12V Pin 3: Not connected Pin 4: Not connected Pin 5: +5V Pin 6: Data + Pin 7: Data Pin 8: GND RS232 Input Canon 9-pin male Front view of the socket: RJ45 socket Front view of the socket: Pin 1: Red LED + Pin 2: Green LED + Pin 3: Blue LED + Pin 4: White LED + Pin 5: Red LED Pin 6: Green LED Pin 7: Blue LED Pin 8: White LED - Pin 1: Not connected Pin 2: Received Data Pin 3: Transmitted Data Pin 4: Pin 5: Signal Ground Pin 6: Pin 7: Pin 8: Pin 9: Not connected 4.Installation 4.1.Connection to the mains The ArcPower 36/K2 is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz AC power source from 100-240 Volts. Carefully prepare the end of the the supply cord and fit a suitable plug.A 3-prong grounding-type plug must be installed following the manufacturer´s instructions.The earth has to be connected! Cord plug connections: Cable Pin International Brown Live Light blue Neutral Yellow/Green Earth L N This device falls under protection class I.Therefore the ArcPower 36/K2 has to be connected to a mains socket outlet with a protective earthing connection. 4.2.Mounting the ArcPower 36/K2 The ArcPower 36/K2 should be be placed on a non-f lammable f lat surface in any orientation and fixed by the two screws.There are two mounting holes of diameter 5 mm in housing of the driver. Ensure that instalation place is enough ventilated. Screw Screw Mounting hole Flat surface 4.3.Conection cables 1.The adapter cable RJ45/XLR connects the ArcPower 36/K2 to the DMX controller.If your DMX controller has RJ45 socket for DMX output,use RJ45 patch cable for connection with the ArcPower 36/K2. RJ45 plug View facing pins DMX 512 XLR plug (male) Front view of the plug Pin 1: Not used Pin 2: Not used Pin 3: Not used Pin 4: Not used Pin 5: +5V Pin 6: Data + Pin 7: Data Pin 8: GND Pin 1: GND Pin 2: Data Pin 3: Data + Pin 4: Not used Pin 5: Not used 2.RJ45 patch cables category 5 that connect the ArcPower 36/K2 each other are wired 1:1,that is,pins with the same numbers are connected together. Pin 1: Not used Pin 2: Not used Pin 3: Not used Pin 4: Not used Pin 5: +5V Pin 6: Data + Pin 7: Data - Pin 8: GND Pin 1: Not used Pin 2: Not used Pin 3: Not used Pin 4: Not used Pin 5: +5V Pin 6: Data + Pin 7: Data Pin 8: GND 5.Installing instructions. Never connect 1W LED modules to the ArcPower 36/K2 5.1.DMX operating 1.Unplug from the mains before installation. 2.Connect the LED modules to the fixture.Make sure that all modules include K2 Luxeon LEDs. 3.Connect DMX controller to the fixture 4.Connect the fixture to the mains 5.Set the DMX address of the fixture (see chapter "8.1 Addressing the Arcpower 36/K2"). 6.Check the current limit setting "C.Li" in menu "SPE" (see chapter "8.6 Special functions"). Warning! Accidental connection DMX 512 Input/Output to non-DMX 512 device (e.g.Ethernet network Hub) can damage the ArcPower 36/K2. Maximum total cable length between Arcpower 36/K2 and all connected LED modules is 40 metres. Single ArcPower 36/K2 installation: Multiple ArcPower 36/K2 installation: Connect the DMX output of the first ArcPower 36/K2 with the DMX input of the next ArcPower 36/K2. Always connect one output with the input of the next ArcPower 36/K2 until all fixtures are connected.In this way,up to 32 fixtures can be chained together. At the last ArcPower 36/K2 the data link has to be terminated with a terminator. A termination plug is simply a RJ45 connector with a 120 Ω resistor between pins Data (–) and Data (+).Plug terminator in the DMX output of the last ArcPower 36/K2. Maximum number of LEDs connected to the one ArcPower 36/K2 is 42 (but maximum12 LEDs per colour). Note: You cannot combine RGB and RGBW modules each other as white LEDs will not light. 5.2.Master-slave operating 1.Unplug from the mains before installation. 2.Connect the LED module to the fixtures. 3.Connect the DMX output of the master fixture in the data-chain with the DMX input of the first slave. Always connect output with the input of the next slave until all slaves are connected.Up to 32 fixtures can be connected in master/slave chain 4.Insert the termination plug (with 120 Ohm) into DMX input of the master fixture and into the DMX output of the last slave fixture in the link in order to ensure proper transmission on the data link. 5.Connect the fixtures to the mains. 6.Check the current limit setting "C.Li" in menu "SPE" (see chapter "8.6 Special functions"). 7.See chapter "8.5.Stand-alone mode" in order to set the fixture as a master or slave. 5.3. Operating via DyNet protocol 1.Unplug from the mains before installation. 2.Connect LED modules to the fixtures. Connect first fixture to the control panel which suports DyNet protocol (e.g. DLP 8100) 3.Connect the DMX output of the first fixture in a data link with the DMX input of the second fixture. Always connect output with the input of the next fixture until all fixtures are connected.Up to 32 fixtures can be connected in data chain. 4.Insert the termination plug (with 120 Ohm) into DMX output of the last fixture in order to ensure proper transmission on the data link. 5.Connect fixtures to the mains 6.Select the DyNet protocol on all fixtures (menu SPE"---> Prt---> "dYn"). A description of each byte in DyNet protocol is the following: Byte 0: 1C - hexadecimal Logical Message Byte 1: 01 - Area Byte 2: 00 – Channel level Byte 3: 80 - Channel Byte 4: ff – Channel Offset Byte 5: 00 – Fade Rate Byte 6: FF Byte 7: 1C Checksum (fixed value) (fixed value) Area - (0 to 255), as set on the Arcpower to give a unique address for each Arcpower unit (i.e. DMX base address) Channel Level - (0 to 255), level - 01=100%, FF=0% Channel - (80 to 83), 80= channel 1, 81= channel 2, 82= channel 3, 83= channel 4, (see Channel Offset if more than 4 channels) Channel Offset - (0-255), default (FF)- channel offset in blocks of 4: (FF = CH 1-4, 00 = CH 5-8, 01 = CH 9-12, etc up to 3E = CH 253-256 ) Fade Rate - (0-255), fade rate with 1 second resolution (0= 0 seconds, 255= 255 seconds) Checksum - (0-255), checksum Byte - used to ensure the integrity of the packet. Negative two's compliment of the preceding 7 bytes. Example 1: 0x1C,0x10,0x00,0x80,0xff,0x05,0xff,0x52 This would control channel 1 (i.e. Red) of Arcpower unit, address 16 to a Level of 100% with a fade of 5 seconds. Example 2: 0x1C,0x05,0xCC,0x82,0xff,0x0A,0xff,0x52 This would control channel 3 (i.e. Blue) of Arcpower unit, address 5 to a level of 20% with a fade of 10 seconds. 10 6.ArcPower 36/K2 - Control menu map Default settings=Bold print 001 (001-506) PrG E.P.1 E.P.2 E.P.3 P.01 : P.10 Aut (OFF,On) EdI. E.P.1 E.P.2 E.P.3 S.01 : S.50 End rEd (0-255) MAn. : rEd (0-255) FA.t.(0-255) GrE. (0-255) S.tI. (0-255) bLu. (0-255) COP. Whi. (0-255) MAC. (0-255) Str. (0-255) diM. (0-255) tSt St.A. MSt. SLA. E.P.1 : P10 SPE. VEr. bAL.(On,OFF) C.bA. rE.b. (0-200) Gr.b. (0-255) bL.b. (0-215) Zon (Z.00-Z.09) d.MP. Mo.1 Mo.2 Mo.3 Mo.4 Mo.5 i.bL (On,OFF) Prt (dMH,dYn) C.Li. UPd.(No,YES) rEd (420,700) GrE(420,700) blu (420,700) Whi (420,700) 11 7.ArcPower 36/K2 - DMX protocol version 2.0 (from software version 2.3 and higher) Mode/Channel Value Function Type of control 1 2 3 4 5 1 1 1 1 1 0-255 RED LEDs Red LEDs saturation control (0-100%) proportional 2 2 2 2 2 0-255 GREEN LEDs Green LEDs saturation control (0-100%) proportional 3 3 3 3 3 0-255 BLUE LEDs Blue LEDs saturation control (0-100%) proportional 0-255 WHITE LEDs White LEDs saturation control (0-100%) proportional 4 4 4 0-7 8-15 16-23 24-31 32-39 40-47 48-55 56-63 64-71 72-79 80-87 88-95 96-103 104-111 112-119 120-127 128-135 136-143 142-151 152-159 160-167 168-175 176-183 184-191 192-199 200-207 208-215 216-223 224-231 232-239 240-247 248-255 5 5 6 6 7 0-31 32-63 64-95 96-127 128-143 144-159 160-191 192-223 224-255 4 0-255 MACRO SELECTION No function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro 13 Macro 14 Macro 15 Macro 16 Macro 17 Macro 18 Macro 19 Macro 20 Macro 21 Macro 22 Macro 23 Macro 24 Macro 25 Macro 26 Macro 27 Macro 28 Macro 29 Macro 30 Rainbow effect with variable speed step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step proportional SHUTTER/STROBE Shutter closed Shutter open Strobe-effect from slow to fast Shutter open Opening pulses in sequences slow--> fast Closing pulses in sequences fast --> slow Shutter open Random strobe-effects from slow to fast Shutter open step step proportional step proportional proportional step proportional step DIMMER Dimmer intensity from 0% to 100% proportional 12 8.Control board The control panel situated on the top cover of the ArcPower 36/K2 allows DMX addressing,calling built-in programs and setting the fixture behaviour Control elements: [ENTER] button- enters menu,confirms adjusted values and leaves menu. , [UP] button and[DOWN] button- moves between menu items on the the same level, sets values. In order to leave the menu without saving value,press [UP] and [DOWN ] at the same time. After switching on the ArcPower 36/K2 ,the display shows the initial DMX address: Use [UP],[DOWN] to browse through the menu. To select a function or submenu,press [ENTER]. 8.1 Addressing the ArcPower 36/K2 The fixture can be uperatated in the two modes:DMX mode-fixture is controlled via DMX 512 by an external DMX controller Stand-alone mode - fixture uses build-in programs and is able to control other fixtures in the master/slave chain. See the chapter "Stand-alone mode" for detail description. For DMX mode is important the DMX start address that is defined as the first channel from which the ArcPower 36/K2 will respond to the DMX controller. Setting the DMX start channel for DMX operating: 1. Connect ArcPower 36/K2 to the mains. 2. Browse through the menu by pressing the [UP] and [DOWN] buttons until the display shows current addres "001".Confirm by pressing [ENTER] button and "001" will start to flash frequently. 3. Use the [UP] and [Down] buttons to select the desired address. 4. Confirm by pressing [ENTER]. After having addressed ArcPower 36/K2, you may now start operating ArcPower 36/K2 via your DMX controller. 8.2 Program running By enter to this menu a complete overview of all programs is offered,from which the program to be run can be selected by pressing [ENTER].Selected program runs in a loop.The fixture includes 10 built-in programs (P.01-P.10) and 3 free editable programs (E.P.1-E.P.3),each up to 50 steps. If Item "AUt" is On,the fixture in DMX mode will remember last running program and this program will run after switching on the fixture. Each program step has a fade time-the time during which effects go to the current step and a Standing time-the time,during which effects last in the current step. 13 Programming procedure: 1. Enter "EdI." menu 2. Press [UP] or [DOWN] to select the desired program which you wish to edit and press [ENTER]. 3. Press [UP] or [DOWN] to select the desired program step ("S.01" - "S.50") and press [ENTER]. 4. Press [UP] or [DOWN] to select the desired item and press [ENTER]-button.Now you can edit by using [UP] or [DOWN] buttons the DMX values selected item (the list of items depends on selected DMX mode): End. - a total number of the program steps (value 1-50).This value you must set before start programming(e.g. if you want to create program with 10 steps,set End=10). rED - a red LED saturation,value 0-255 GrE. - a green LED saturation,value 0-255 bLu. - a blue LED saturation,value 0-255 Whi. - a white LED saturation,value 0-255 MAC. - a macro selection,value 0-255 Str. - a strobe,value 0-255 dim. - a dimmer,value 0-255 FA.t. - fade time,value 0-255 * S.tI. - standing time,value 0-255 * COP. - copying the current prog. step to the next prog. step. Press [ENTER]-button to confirm adjusted value . 5.Repeat steps 3 and 4 for next prog.step.If you want to copy current prog. step to the next prog.step, select option "COP."and confirm it by pressing [ENTER]. *Both Fade time and Standing time use the same conversion table in order to convert DMX value to the time value: DMX Time [sec.] DMX Time [min.] DMX Time [min.] DMX Time [min.] DMX Time [min.] 1 0.1 50 4.2 105 18.4 160 42.7 215 77 2 0.4 55 5 110 20.2 165 45.4 220 80.7 5 2.5 60 6 115 22 170 48.2 225 84.4 10 10 65 7 120 24 175 51 230 88.2 15 22.5 70 8.2 125 26 180 54 235 92 20 40 75 9.4 130 28.2 185 57 240 96 25 62.5 80 10.7 135 30.4 190 60.2 245 100 30 90 85 12 140 32.7 195 63.4 250 104 35 122.5 90 13.5 145 35 200 66.7 255 108 40 160 95 15 150 37.5 205 70 45 202.5 100 16.7 155 40 210 73.5 Exact expression of the time value follows the formula: time[sec.]=(DMX value)2/10. 8.3 Manual mode This menu gives access to the control of the fixture channels by means of the control buttons. Use [UP] and [DOWN] buttons until the display shows "MAn." menu.Press [ENTER] button and by using [UP] and [DOWN] buttons select desired effect,press [ENTER] and and by using [UP] and [DOWN] buttons adjust desired DMX value for selected effect.Confirm by [ENTER]. rED a red LED saturation GrE. a green LED saturation bLu. a blue LED saturation Whi. a white LED saturation MAC a macro selection Str. a strobe dim. a dimmer 14 8.4 Test sequences Use the item to run a special demo-test sequences without an external controller,which will show you some possibilities of using the fixture. 8.5 Stand-alone mode Select this menu to set fixture behaviour in stand-alone mode without an external controller. Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master ("MSt") and the rest as the slaves ("SLA").Only one fixture can be set as the master.The slaves mimic the behavior of the master.Effect actions are triggered by an internal timer of the master fixture. Important!:Disconect the fixtures from the DMX controller before master/slave operating ,otherwise data collisions can occur and the fixtures will not work properly! MSt. --- Master.Enter this menu if you want to set the the fixture as a master.Use [UP] and [DOWN] buttons to select desired program and press [ENTER] to confirm selection. SLA. --- Slave.Enter this menu if you want to set the the fixture as a slave. The master fixture starts simultaneous program start in the other slave fixtures.All fixtures are synchronized in every prog.steps.The fixtures run their programs repeatedly (e.g. if master runs its program "P05",all slaves will be executed program "P05" too). Note: If the master runs its editable program (EP1,EP2 or EP3),all slaves will execute their own editable programs (EP1,EP2 or EP3) according the master,but both fade time (FA.t.) and standing time (S.tI.) for each step will be taken from the master´s step (slaves´ times are eliminated in each step). 8.6 Special functions Use this menu for special services. VEr. --- Software Version.Select this function to read the number of the fixture software. bAL. --- Balance.Select this function to enable (On) or disable (OFF) the white balance which is set in "White colour balance" menu below.If this function is set OFF,ArcPower 36/K2 will use maximum values (255) of saturation for red, green and blue channel. C.bA. --- White colour balance. Using this menu you can set white balance: 1. Browse through the menu by pressing the [UP] and [DOWN] buttons until the display shows "C.bA." menu.Press [ENTER] button and "rE.b." will appear on the display. 2.Press [ENTER] button again and use [UP] and [DOWN] buttons to adjust the new maximum value required for the red channel.Confirm your choice by pressing [ENTER].Use the [UP] and [Down] buttons to select next colour. 3.Repeat step 2 for green channel "Gr.b." and for blue channel "bL.b". d.MP. --- DMX presetting.The function enables to select from the 5 DMX-channel modes.Use [UP] and [DOWN] buttons to select desired channel mode(“Mo.1,Mo.2,Mo.3,Mo.4,Mo.5”) and press [ENTER] to confirm selection. Zon. --- Zone selecting.The number of the zone distinguishes individual drivers which are controled via RS232 interface.Use [UP] and [DOWN] buttons to select desired zone (from 0 to 9) and press [ENTER] to confirm selection.For futher information see chapter "Control of the ArcPower 36/K2 via RS-232 ". i.bL. --- Initial blink.If this function is on,ArcPower 36/K2 makes auto-calibration (All LEDs light on 100% for short time) after switching it on.If this function is set off,you have to set manually every colour on max.brightness after switching on the driver before starting regular operating.This action should last min. one second.In this moment, the ArcPower 36/K2 finds out the load connected to its LED output and makes auto-calibration. 15 Prt --- Protocol selection - Selects a required communication protocol. dMH - the fixture will communicate using DMX 512 signal. dYn - the fixture will communicate using the DyNet protocol. C.Li. --- Current limiting.The menu item allows to set right current-carrying capacity of each LED branch (colour) in order to keep declared lifetime of LED modules: Red,amber LEDs..............420 mA Green,blue,white LEDs....700mA The LED modules use 3 internal branches for LED supply for both three-colour (e.g. RGB,AGB) and singlecolour variants (R,A,G,B,W).It means that in case of a single colour variant of LED module right values of the current limiting have to be set at "rEd","GrE" and "bLu" items as well. Four-colour variants of LED modules (e.g. RGBW,AGBW) use 4 internal branches for LED supply and all items "rEd","GrE" , "bLu" and "Whi" have to be set at correct values. The menu items (their name and order) stated below match to a standard RGBW colour variant of LED module. rEd=red LED(s) R GrE=green LED(s) G bLu=blue LED(s) B Whi=white LED(s) W Examples of recommended settings for different LED colour combinations: Colour combination Menu item RGB RGBW* R A G B WW/CW AGB GAB** rEd 420 420 420 420 700 700 700 420 700 GrE 700 700 420 420 700 700 700 700 420 bLu 700 700 420 420 700 700 700 700 700 Whi 700 700 420 420 700 700 700 700 700 * default setting ** This is an example:by reason that order of items in the menu "C.Li" is constant,for GAB colour combination the item "GrE" has to be set to 420 (letter A is on the second position in the name of the colour combination and on the second position in the menu C.Li" is the item "GrE"). To adjust current limiting: 1. Browse through the menu by pressing the [UP] and [DOWN] buttons until the display shows "C.Li." menu.Press [ENTER] button and "rEd" item will appear on the display. 2.Press [ENTER] button again and use [UP] and [DOWN] buttons to select desired value. Confirm this value by pressing [ENTER].Use the [UP] and [Down] buttons to select next colour. 3.Repeat step 2 for items "GrE", "bLu"and "Whi". UPd. --- Software update - Using this function you can update software in the fixture via PC and serial link. The following are required in order to update software: - PC running Windows 95/98/2000/XP or Linux - DMX Software Uploader - Flash cable RS232/DMX (No.13050624) Note1:Software update should execute a qualified person.If you lack qualification, do not attempt the update yourself and ask for help your ANOLIS distributor. Note 2:DMX address,programs and all settings will be set to their default values. To update software in the fixture: 1.Installation of DMX Software Uploader: 1.DMX Software Uploader program is available from the ANOLIS web site at WWW.anolis.cz. 2.Make a new directory ( e.g. ANOLIS_Uploader) on your hard disk and download the software to it. 3.Unpack the program from the archives. Program file has name:DSU_name of corresponding fixture_SoftwareID.SoftwareID describes the versions of fixture software included in DMX Software Uploader. Higher number means later software versions. 2.Fixture software updating: 1.Determine which of your COM port is available on your PC and connect it with to the DMX input of the fixture using the Flash cable. Do not extend this cable! Disconnect the fixture from the other fixtures in DMX chain! Turn on the computer and the fixture. 2.Switch the fixture to the update mode by selecting the option Software update in menu Special 16 Functions on the fixture control panel:SPE-->UPd-->yES.(From this option you cannot return back to the main menu. If you do not want to continue in software update, you have to switch off and on the fixture to leave this option!) 3.It is recommended that you exit all programs before running the Software Uploader. 4.Start the Software Uploader program. Select desired COM and then click Connect button. If the conection is OK, click Start Uploading button to start uploading. It will take several minutes to perform software update.All processors will be updated (including processors with the same software version). If you wish to update only later versions of processors, enable the Incremental Update check box. Avoid interrupting the process. Update status is being displayed in the list window. When the update is finished, the line with the text “The fixture is successfuly updated‘ will appear in this window and the fixture will reset with the new software. Note: In the case of interruption of the upload process (e.g. power cut), the fixture remains in the update mode and you have to repeat the software update again. For example: The fixture was switched off before finishing software upload. After switching the fixture on again, the fixture is still in the update mode and the display is dark. Restart the Software Uploader program and repeat software update from your PC. 17 9.Control of the ArcPower 36/K2 via RS-232 9.1Wiring an RS-232 serial port 9-pin D connector (male) Front view of the socket: Pin 1: Not connected Pin 2: Received Data Pin 3: Transmitted Data Pin 4: Pin 5: Signal Ground Pin 6: Pin 7: Pin 8: Pin 9: Not connected RS-232 cable: 9-pin D connector- female ArcPower/K2 driver 9-pin D connector - female PC Pin 1: Pin 1: Pin 2: Received Data Pin 2: Received Data Pin 3: Transmited data Pin 3: Transmited data Pin 4: Pin 4: Pin 5: Signal ground Pin 5: Signal ground Pin 6: Pin 6: Pin 7: Pin 7: Pin 8: Pin 8: Pin 9: Pin 9: The maximum cable length according to the standard is 15 metres or the cable length equals to a capacitance of 2500 pF. 9.2 Selecting a zone The number of the zone distinguishes individual drivers which are controled via RS-232 interface. Select SPE in main menu of the ArPower 36/K2 ,press [ENTER],use [UP] and [DOWN] buttons to select Zon. The option enables to select desired number of the zone (from 0 to 9).Press [ENTER],use [UP] and [DOWN] buttons to select zone number and press [ENTER] to confirm selection. 9.3 Setting a serial port of PC The serial port of your personal computer hould be configured as follows: 9600 Baud,8 Data Bits,Non Parity,One Stop Bit,No Flow Control Required. 9.4 Zone commands The ArcPower 36/K2 uses the 3 types of the zone commands which can be used in a suitable software running on PC. All zone commands stated below have to be send to the ArcPower 36/K2 in ASCII codes. Type 1: Selection of the preset colours The syntax of the command is: zone Z red; zone Z green; 18 zone Z blue; zone Z white; zone Z yellow; zone Z cyan; zone Z magenta; zone Z blackout; Z ...........means number of the zone (0-9) red/green/blue/white/yellow/cyan/magenta....determines colour blackout.......closes light output ;.............means end of character sequence Examples: zone 4 green; zone 0 blackout; Type 2: Colour mixing-RGB The syntax of the command is: zone Z r,g,b; Z............ means number of zone (0-9) r .............means DMX value of the red colour(0-255) g ............means DMX value of the green colour (0-255) b ............means DMX value of the blue colour (0-255) ; .............means end of character sequence , ..............values of colours have to be separated by a comma. Examples: zone 0 234,126,165; zone 1 5,18,28; Type 3: Colour mixing-RGBW The syntax of the command is: zone Z r,g,b,w; Z............ means number of zone (0-9) r .............means DMX value of the red colour(0-255) g ............means DMX value of the green colour (0-255) b ............means DMX value of the blue colour (0-255) w ............means DMX value of the white colour (0-255) ; .............means end of character sequence , ..............values of colours have to be separated by a comma. Examples: zone 0 156,145,171,211; zone 1 5,18,28,148; 19 10.Technical Specifications: Power supply: Input Voltage: 100-240 V AC, 50/60 Hz Fuse:T 2 A H Max.Pover Consumption:120VA Input: Control:DMX 512 or Dynet protocol DMX connection:RJ45 RS 232 connection:9-pin D connector Output: Max.Output Voltage:48V DC Max.Output current:700 mA per colour Max.load: 36x K2 LED´s in RGB mode 42x K2 LED´s in RGBW mode Maximum total cable length between Arcpower 36/K2 and all connected LED modules: 40 metres at max.load DMX channels: Channel Mode 1 Mode 2 Mode 3 Mode 4 Mode 5 1 Red LEDs Red LEDs Red LEDs Red LEDs Red LEDs 2 Green LEDs Green LEDs Green LEDs Green LEDs Green LEDs 3 Blue LEDs Blue LEDs Blue LEDs Blue LEDs Blue LEDs 4 White LEDs Macros White LEDs Dimmer 5 Shutter/Strobe Macros 6 Dimmer Shutter/Strobe 7 Dimmer Control and programming: Protocol: USITT DMX-512 Three DMX protocol modes for RGB light sources Two DMX protocol modes for RGBW light sources Control options:DMX,Auto-trigger Operation modes:Master/Slave,Stand alone Programs:10 build-in programs+3 user editable programs up to 50 steps each Display:3 digit LED White colour balance adjusting Manual control of all DMX channels with LED control panel Operating temperature: -10°C/+40°C Max.surface temperature: +60°C Dimensions(mm): 20 Weight: 1.8 kg Accessories: Cable joiner ...............1piece Optional accessories: Adaptor RJ45/DMX 3 pin.......No.13050730 Adaptor RJ45/DMX 5 pin.......No.13050731 11. Replacing the fuse 1.Before replacing the fuse, unplug mains lead! 2.Unscrew the fuse holder on the rear side of the ArcPower 36/K2 with a fitting screwdriver from the housing (anti-clockwise). 3.Remove the old fuse from the fuse holder. 4.Install the new fuse in the fuse holder. 5.Replace the fuse holder in the housing and fix it. Specifications are subject to change without notice. 21
advertisement
Key Features
- DMX 512 or DyNet protocol
- 36x K2 LEDs in RGB mode, 42x in RGBW
- Master/Slave, Stand alone operation modes
- 10 built-in programs + 3 user editable
- White colour balance adjusting
- Manual control of all DMX channels
- Software update via RS232