Regency HZO42 Outdoor Gas Fireplace SpecSheet

Regency HZO42 Outdoor Gas Fireplace SpecSheet

Regency HZO42 is a versatile outdoor gas fireplace designed to bring warmth and ambiance to your patio or outdoor living space. Fueled by either natural gas or propane, it offers adjustable heat output and a clean-burning flame with no smoke or ash. Installation is relatively straightforward, requiring an open-air location with proper ventilation. Its compact design allows for flexible placement, while the included remote control and multiple safety features ensure ease of use and peace of mind.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Regency HZO42 Outdoor Gas Fireplace SpecSheet | Manualzz

37 - 13/16” (960mm)

41 - 11/16” (1059mm)

43 - 11/16” (1110mm)

39 - ½” (1003mm)

35 - 1/4” (895mm)

Specifications:

Model

Fuel Type

Minimum Supply

Pressure

Manifold Pressure - High

HZO42-NG

Natural Gas

5” W.C.

(1.25 kPa)

3.5” W.C.

(0.87 kPa)

#29 DMS Orifice Size

Minimum Input

Altitude 0-4500 ft.

(0-1372m)

Maximum Input

Altitude 0-4500 ft.

(0-1372m)

Vent Sizing

Unit Dimensions:

44,500 Btu/h

(13.04 kW)

44,500 Btu/h

(13.04 kW)

No Vent

37 - 13/16” (960mm)

41 - 11/16” (1059mm)

43 - 11/16” (1110mm)

16 - 1/8” (410mm)

15 - 9/16” (395mm)

35 - 1/4” (895mm)

HZO 42 Outdoor Gas Fireplace

HZO42-LP

Propane Gas

11” W.C.

(2.74 kPa)

10” W.C.

(2.49 kPa)

#47 DMS

43,500 Btu/h

(12.74 kW)

43,500 Btu/h

(12.74 kW)

No Vent

Framing Dimensions:

D

G

H

E

F

J

I

Framing

Dim

A

B

C

K

Description

Header Height

Side Stud Width

Minimum framing depth

Minimum Height to Combustibles

Minimum framing width

Corner Wall Depth

Corner Facing Wall Width

Gas Connection Opening Height

Gas Connection Height

Gas Connection Inset

Gas Connection Opening Width

HZO42

32-11/16” (30mm)

42 - 3/16" (1072mm)

20" (508mm)

52 - 1/2" (1334mm)

60" (1524mm)

40 - 7/16" (1027mm)

54 - 3/16" (1376mm)

2" (51mm)

3-7/8 " (98mm)

3/4" (73mm)

3-7/8 " (98mm)

* Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible.

16 - 1/8” (410mm)

material & wall finishes.

13 - 3/4” (349mm)

5/8” (16mm)

37 - 13/16” (960mm)

5/8” (16mm)

Note: All other framing may be of wood construction.

Metal Stud on edge

A

41 - 11/16” (1059mm)

43 - 11/16” (1110mm)

39 - ½” (1003mm)

35 - 1/4” (895mm)

D

E

B

16 - 1/8” (410mm)

15 - 9/16” (395mm)

13 - 3/4” (349mm)

5/8” (16mm)

F

C

J

K

I

J

G

HZO42 Gas Fireplace

Clearance Requirements:

Clearance:

A: Sidewall

B: Ceiling

Dimension

11" (203mm)

36" (914mm)

Measured From:

Side of Fireplace Opening

Top of Fireplace Opening

C: Mantel Height (min.) 26-1/2" (673mm) Top of Fireplace Opening

D: Mantel Depth (max.) 12" (304mm) From Wall

E: Alcove Width

F: Alcove Depth

Notes:

57"(1148mm)

36" (914mm)

0"

Wall to Wall (Minimum)

Front to Back Wall (Maximum)

No Hearth Required

F

E

Alcove

B

C

D

E

A

F

Combustible Mantels:

Due to the extreme heat this fireplace emits, the mantel clearances

are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right.

Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour.

26

14 12 10 8 6 4 2

0

12" (305mm)

Combustible Material

20

10

26-1/2”

1" (25mm)

18”

Metal Stud

(On Edge)

Non-combustible

Facing

11”

Standoff

0

To Unit

Base

23”

Top of

Fireplace

Opening

HZO42 Gas Fireplace

FINISHING

IMPORTANT FINISHING DETAIL NOTE:

Before placing unit into final position - it is important to know the total thickness / height of finished hearth. The base of the fireplace should be level or higher than the finished hearth height.

Non-Combustible Requirements:

43-11/16” (1110mm)

Non-combustible

Material

38-1/16” (767mm)

Non-combustible Material

2-7/8”

6-9/16”

(167mm)

HZO42 Gas Fireplace

LOCATING YOUR

GAS FIREPLACE

1) When selecting a location for your fireplace, ensure that the clearances are met.

2) This appliance must be installed in an open-air situation with natural ventilation, without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection.

3) Certain materials or items, when placed under or near the appliance, will be subjected to radiant heat and could become damaged.

4) Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used shall comply with one of the following:

An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead cover.

Within a partial enclosure that includes an overhead cover and no more that two walls.

Within a partial enclosure that includes an overhead cover and more than two walls, the following shall apply:

At least 25% of the total wall area is completely open, and

At least 30% of the remaining wall area is open and unrestricted

30% or more in total of the remaining wall area is open and unrestricted.

Open side at least 25% of total wall area

advertisement

Related manuals

Download PDF

advertisement