Regency HZO42 is a versatile outdoor gas fireplace designed to bring warmth and ambiance to your patio or outdoor living space. Fueled by either natural gas or propane, it offers adjustable heat output and a clean-burning flame with no smoke or ash. Installation is relatively straightforward, requiring an open-air location with proper ventilation. Its compact design allows for flexible placement, while the included remote control and multiple safety features ensure ease of use and peace of mind.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
37 - 13/16” (960mm)
41 - 11/16” (1059mm)
43 - 11/16” (1110mm)
39 - ½” (1003mm)
35 - 1/4” (895mm)
Specifications:
Model
Fuel Type
Minimum Supply
Pressure
Manifold Pressure - High
HZO42-NG
Natural Gas
5” W.C.
(1.25 kPa)
3.5” W.C.
(0.87 kPa)
#29 DMS Orifice Size
Minimum Input
Altitude 0-4500 ft.
(0-1372m)
Maximum Input
Altitude 0-4500 ft.
(0-1372m)
Vent Sizing
Unit Dimensions:
44,500 Btu/h
(13.04 kW)
44,500 Btu/h
(13.04 kW)
No Vent
37 - 13/16” (960mm)
41 - 11/16” (1059mm)
43 - 11/16” (1110mm)
16 - 1/8” (410mm)
15 - 9/16” (395mm)
35 - 1/4” (895mm)
HZO 42 Outdoor Gas Fireplace
HZO42-LP
Propane Gas
11” W.C.
(2.74 kPa)
10” W.C.
(2.49 kPa)
#47 DMS
43,500 Btu/h
(12.74 kW)
43,500 Btu/h
(12.74 kW)
No Vent
Framing Dimensions:
D
G
H
E
F
J
I
Framing
Dim
A
B
C
K
Description
Header Height
Side Stud Width
Minimum framing depth
Minimum Height to Combustibles
Minimum framing width
Corner Wall Depth
Corner Facing Wall Width
Gas Connection Opening Height
Gas Connection Height
Gas Connection Inset
Gas Connection Opening Width
HZO42
32-11/16” (30mm)
42 - 3/16" (1072mm)
20" (508mm)
52 - 1/2" (1334mm)
60" (1524mm)
40 - 7/16" (1027mm)
54 - 3/16" (1376mm)
2" (51mm)
3-7/8 " (98mm)
3/4" (73mm)
3-7/8 " (98mm)
* Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible.
16 - 1/8” (410mm)
material & wall finishes.
13 - 3/4” (349mm)
5/8” (16mm)
37 - 13/16” (960mm)
5/8” (16mm)
Note: All other framing may be of wood construction.
Metal Stud on edge
A
41 - 11/16” (1059mm)
43 - 11/16” (1110mm)
39 - ½” (1003mm)
35 - 1/4” (895mm)
D
E
B
16 - 1/8” (410mm)
15 - 9/16” (395mm)
13 - 3/4” (349mm)
5/8” (16mm)
F
C
J
K
I
J
G
HZO42 Gas Fireplace
Clearance Requirements:
Clearance:
A: Sidewall
B: Ceiling
Dimension
11" (203mm)
36" (914mm)
Measured From:
Side of Fireplace Opening
Top of Fireplace Opening
C: Mantel Height (min.) 26-1/2" (673mm) Top of Fireplace Opening
D: Mantel Depth (max.) 12" (304mm) From Wall
E: Alcove Width
F: Alcove Depth
Notes:
57"(1148mm)
36" (914mm)
0"
Wall to Wall (Minimum)
Front to Back Wall (Maximum)
No Hearth Required
F
E
Alcove
B
C
D
E
A
F
Combustible Mantels:
Due to the extreme heat this fireplace emits, the mantel clearances
are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right.
Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour.
26
14 12 10 8 6 4 2
0
12" (305mm)
Combustible Material
20
10
26-1/2”
1" (25mm)
18”
Metal Stud
(On Edge)
Non-combustible
Facing
11”
Standoff
0
To Unit
Base
23”
Top of
Fireplace
Opening
HZO42 Gas Fireplace
FINISHING
IMPORTANT FINISHING DETAIL NOTE:
Before placing unit into final position - it is important to know the total thickness / height of finished hearth. The base of the fireplace should be level or higher than the finished hearth height.
Non-Combustible Requirements:
43-11/16” (1110mm)
Non-combustible
Material
38-1/16” (767mm)
Non-combustible Material
2-7/8”
6-9/16”
(167mm)
HZO42 Gas Fireplace
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your fireplace, ensure that the clearances are met.
2) This appliance must be installed in an open-air situation with natural ventilation, without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection.
3) Certain materials or items, when placed under or near the appliance, will be subjected to radiant heat and could become damaged.
4) Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used shall comply with one of the following:
An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead cover.
Within a partial enclosure that includes an overhead cover and no more that two walls.
Within a partial enclosure that includes an overhead cover and more than two walls, the following shall apply:
•
•
At least 25% of the total wall area is completely open, and
At least 30% of the remaining wall area is open and unrestricted
30% or more in total of the remaining wall area is open and unrestricted.
Open side at least 25% of total wall area
advertisement