Elastimold 1250A 33kV Bolted Tee Connectors 35-630sqmm

Add to my manuals
2 Pages

advertisement

Elastimold 1250A 33kV Bolted Tee Connectors 35-630sqmm | Manualzz

Application

Separable tee connector (bolted

5/8" type) designed to connect polymeric insulated cable to equipment (transformers, switch gear, motors...).

Also connects cable to cable, using the appropriate mating part.

CABLE JOINTS, CABLE TERMINATIONS, CABLE GLANDS, CABLE CLEATS

FEEDER PILLARS, FUSE LINKS, ARC FLASH, CABLE ROLLERS, CUT-OUTS

11KV 33KV CABLE JOINTS & CABLE TERMINATIONS

FURSE EARTHING www.cablejoints.co.uk

Thorne and Derrick UK

Tel 0044 191 490 1547 Fax 0044 191 477 5371

Tel 0044 117 977 4647 Fax 0044 117 9775582

Technical characteristics

• A thick conductive EPDM jacket provides a total safe to touch screen.

• Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory.

750LR & 775LR

INTERFACE E - 5/8"

TEE CONNECTOR

Up to 36 kV

800 A & 1250 A

6/10 (12) kV

6.35/11 (12) kV

8.7/15 (17.5) kV

12/20 (24) kV

12.7/22 (24) kV

18/30 (36) kV

295 mm

260 mm

Design

Separable connector comprising:

1. Conductive EPDM insert.

2. Conductive EPDM jacket.

3. Insulating EPDM layer moulded between the insert and the jacket.

4. Type E interface as described in ANSI/IEEE std.

386.

5. Threaded stud 5/8".

6. Conductor connector.

7. Cable reducer.

8. Dead end plug (with VD point).

9. Conductive rubber cap.

10. Cable adaptor.

355 mm

1

2

4

6

3

7

5

8 9

Specifications and standards

The separable connectors

750LR and 775LR meet the requirements of CENELEC HD

629.1.

Separable connector type

750LR

775LR

Voltage

Um

(kV)

36

36

Current

Ir

(A)

800

1250

10

Conductor sizes (mm 2 ) min.

35

35 max.

630

630

4

Kit contents

The complete 750LR or 775LR tee connector kit comprises the following components:

The kit also comprises lubricant, wipers, installation instructions and crimp chart.

Connector housing

750BLR

+

Conductor contact

TBC-X1 or TBC-X2

+

Dead end plug

+ rubber cap

750DP or 775DP

+

Cable reducer

755CA-W

+

Cable adaptor

11TL

=

750LR-W-X1+11TL or

775LR-W-X2+11TL connector kit

Ordering instructions

Select the part number which gives the best centring to the cable core insulation diameter.

Example:

The copper wire screened cable is 36 kV, 300 mm 2 stranded aluminium with a diameter over core insulation of 38.8 mm.

Order a 750LR-M-300KM-10-

Table W

Ordering part number - 800 A

750LR-G-X1+11TL

750LR-H-X1+11TL

750LR-J-X1+11TL

750LR-K-X1+11TL

750LR-L-X1+11TL

750LR-M-X1+11TL

750LR-N-X1+11TL

750LR-P-X1+11TL

750LR-Q-X1+11TL

800 A application.

Table X

Conductor sizes

(mm²)

120

150

185

240

35

50

70

95

300

400

500

630

Table X1: 800 A

Aluminium conductor Copper conductor

DIN hexagonal

Deep indent

DIN hexagonal

35(K)M-10-2

50(K)M-10-2

70(K)M-10-2

95(K)M-10-2

120(K)M-10-2

150(K)M-10-2

185(K)M-10-2

240(K)M-10-2

300(K)M-10-2

400(K)M-10-2

500(K)M-10-2

630(K)M-10-2

35KM-10-1

50(K)M-10-1

70(K)M-10-1

95(K)M-10-1

120(K)M-1 0-1

150(K)M-1 0-1

185(K)M-1 0-1

240(K)M-1 0-1

300(K)M-1 0-1

400(K)M-1 0-1

500(K)M-1 0-1

630(K)M-1 0-1

35(K)M-14

50(K)M-14

70(K)M-14

95(K)M-14

120(K)M-14

150(K)M-14

185(K)M-14

240(K)M-14

300(K)M-14

400(K)M-14

500(K)M-14

630(K)M-14

Ordering part number - 1250 A

775LR-G-X2+11TL

775LR-H-X2+11TL

775LR-J-X2+11TL

775LR-K-X2+11TL

775LR-L-X2+11TL

775LR-M-X2+11TL

775LR-N-X2+11TL

775LR-P-X2+11TL

775LR-Q-X2+11TL

Dia. over core insulation (mm) min.

max.

19.3

21.6

24.9

27.7

30.0

34.8

38.5

43.8

48.3

24.1

26.7

30.0

33.3

37.2

41.1

45.2

49.1

53.9

Table X2: 1250 A

Aluminium conductor Copper conductor

DIN hexagonal

Deep indent

DIN hexagonal

35(K)M-12-2

50(K)M-12-2

70(K)M-12-2

95(K)M-12-2

120(K)M-12-2

150(K)M-12-2

185(K)M-12-2

240(K)M-12-2

300(K)M-12-2

400(K)M-12-2

500(K)M-12-2

630(K)M-12-2

35KM-1 2-1

50(K)M-1 2-1

70(K)M-1 2-1

95(K)M-1 2-1

120(K)M-1 2-1

150(K)M-1 2-1

185(K)M-1 2-1

240(K)M-1 2-1

300(K)M-1 2-1

400(K)M-1 2-1

500(K)M-1 2-1

630(K)M-1 2-1

35(K)M-11-2

50(K)M-11-2

70(K)M-11-2

95(K)M-11-2

1 20(K)M-11-2

1 50(K)M-11-2

1 85(K)M-11-2

240(K)M-11-2

300(K)M-11-2

400(K)M-11-2

500(K)M-11-2

630(K)M-11-2

For use with copper wire screened cables.

No earthing device is necessary.

For use with copper tape screened cables.

Order: Kit MT.

For use with fabric tape

(graphite) screened cables.

Order additional semi-conductive tape

(type TSC).

For use with other cable types.

Please contact our representative.

For outdoor applications.

Order: +MWS.

Components can be ordered individually.

5

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Download PDF

advertisement