Renesas H8/3834 HS3834ECF61H, H8/3814 HS3834ECF61H, H8/3877 HS3834ECF61H User System Interface Cable, H8/300L HS3L08EPI60H E6000 Emulator, H8/3834, H8/3814, H8/3877 MCU User's Manual

Renesas H8/3834 HS3834ECF61H, H8/3814 HS3834ECF61H, H8/3877 HS3834ECF61H User System Interface Cable, H8/300L HS3L08EPI60H E6000 Emulator, H8/3834, H8/3814, H8/3877 MCU User's Manual

Below you will find brief information for User System Interface Cable H8/3834 HS3834ECF61H, User System Interface Cable H8/3814 HS3834ECF61H, User System Interface Cable H8/3877 HS3834ECF61H. The HS3834ECF61H user system interface cable provides a connection between your system and the H8/300L series E6000 emulator (HS3L08EPI60H) for emulation development. It allows you to debug and test your system. This document describes the configuration and connection procedures for the cable, as well as provides instructions for verifying the operation.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Renesas User System Interface Cable H8/3834 HS3834ECF61H, H8/3814 HS3834ECF61H, H8/3877 HS3834ECF61H User Manual | Manualzz

To our customers,

Old Company Name in Catalogs and Other Documents

On April 1 st

, 2010, NEC Electronics Corporation merged with Renesas Technology

Corporation, and Renesas

Electronics Corporation

took over all the business of both companies.

Therefore, although the old company name remains in this document, it is a valid

Renesas

Electronics document. We appreciate your understanding.

Renesas Electronics website:

http://www.renesas.com

April 1

st

, 2010

Renesas Electronics Corporation

Issued by:

Renesas Electronics Corporation

( http://www.renesas.com

)

Send any inquiries to http://www.renesas.com/inquiry .

Notice

1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to additional and different information to be disclosed by Renesas Electronics such as that disclosed through our website.

2. Renesas Electronics does not assume any liability for infringement of patents, copyrights, or other intellectual property rights of third parties by or arising from the use of Renesas Electronics products or technical information described in this document.

No license, express, implied or otherwise, is granted hereby under any patents, copyrights or other intellectual property rights of Renesas Electronics or others.

3. You should not alter, modify, copy, or otherwise misappropriate any Renesas Electronics product, whether in whole or in part.

4. Descriptions of circuits, software and other related information in this document are provided only to illustrate the operation of semiconductor products and application examples. You are fully responsible for the incorporation of these circuits, software, and information in the design of your equipment. Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from the use of these circuits, software, or information.

5. When exporting the products or technology described in this document, you should comply with the applicable export control laws and regulations and follow the procedures required by such laws and regulations. You should not use Renesas

Electronics products or the technology described in this document for any purpose relating to military applications or use by the military, including but not limited to the development of weapons of mass destruction. Renesas Electronics products and technology may not be used for or incorporated into any products or systems whose manufacture, use, or sale is prohibited under any applicable domestic or foreign laws or regulations.

6. Renesas Electronics has used reasonable care in preparing the information included in this document, but Renesas Electronics does not warrant that such information is error free. Renesas Electronics assumes no liability whatsoever for any damages incurred by you resulting from errors in or omissions from the information included herein.

7. Renesas Electronics products are classified according to the following three quality grades: “Standard”, “High Quality”, and

“Specific”. The recommended applications for each Renesas Electronics product depends on the product’s quality grade, as indicated below. You must check the quality grade of each Renesas Electronics product before using it in a particular application. You may not use any Renesas Electronics product for any application categorized as “Specific” without the prior written consent of Renesas Electronics. Further, you may not use any Renesas Electronics product for any application for which it is not intended without the prior written consent of Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific” or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics. The quality grade of each Renesas Electronics product is “Standard” unless otherwise expressly specified in a Renesas Electronics data sheets or data books, etc.

“Standard”: Computers; office equipment; communications equipment; test and measurement equipment; audio and visual equipment; home electronic appliances; machine tools; personal electronic equipment; and industrial robots.

“High Quality”: Transportation equipment (automobiles, trains, ships, etc.); traffic control systems; anti-disaster systems; anticrime systems; safety equipment; and medical equipment not specifically designed for life support.

“Specific”: Aircraft; aerospace equipment; submersible repeaters; nuclear reactor control systems; medical equipment or systems for life support (e.g. artificial life support devices or systems), surgical implantations, or healthcare intervention (e.g. excision, etc.), and any other applications or purposes that pose a direct threat to human life.

8. You should use the Renesas Electronics products described in this document within the range specified by Renesas Electronics, especially with respect to the maximum rating, operating supply voltage range, movement power voltage range, heat radiation characteristics, installation and other product characteristics. Renesas Electronics shall have no liability for malfunctions or damages arising out of the use of Renesas Electronics products beyond such specified ranges.

9. Although Renesas Electronics endeavors to improve the quality and reliability of its products, semiconductor products have specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use conditions. Further,

Renesas Electronics products are not subject to radiation resistance design. Please be sure to implement safety measures to guard them against the possibility of physical injury, and injury or damage caused by fire in the event of the failure of a

Renesas Electronics product, such as safety design for hardware and software including but not limited to redundancy, fire control and malfunction prevention, appropriate treatment for aging degradation or any other appropriate measures. Because the evaluation of microcomputer software alone is very difficult, please evaluate the safety of the final products or system manufactured by you.

10. Please contact a Renesas Electronics sales office for details as to environmental matters such as the environmental compatibility of each Renesas Electronics product. Please use Renesas Electronics products in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances, including without limitation, the EU RoHS

Directive. Renesas Electronics assumes no liability for damages or losses occurring as a result of your noncompliance with applicable laws and regulations.

11. This document may not be reproduced or duplicated, in any form, in whole or in part, without prior written consent of Renesas

Electronics.

12. Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this document or Renesas Electronics products, or if you have any other inquiries.

(Note 1) “Renesas Electronics” as used in this document means Renesas Electronics Corporation and also includes its majorityowned subsidiaries.

(Note 2) “Renesas Electronics product(s)” means any product developed or manufactured by or for Renesas Electronics.

H8/3834 Series, H8/3814 Series, H8/3877 Series FP-100A

User System Interface Cable (HS3834ECF61H) for

E6000 Emulator

User’s Manual

H8/3834 Series, H8/3814 Series, H8/3877 Series

FP-100A

Rev.4.0 2003.04

Cautions

1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document.

2. Products and product specifications may be subject to change without notice. Confirm that you have received the latest product standards or specifications before final design, purchase or use.

3. Renesas makes every attempt to ensure that its products are of high quality and reliability.

However, contact Renesas’s sales office before using the product in an application that demands especially high quality and reliability or where its failure or malfunction may directly threaten human life or cause risk of bodily injury, such as aerospace, aeronautics, nuclear power, combustion control, transportation, traffic, safety equipment or medical equipment for life support.

4. Design your application so that the product is used within the ranges guaranteed by Renesas particularly for maximum rating, operating supply voltage range, heat radiation characteristics, installation conditions and other characteristics. Renesas bears no responsibility for failure or damage when used beyond the guaranteed ranges. Even within the guaranteed ranges, consider normally foreseeable failure rates or failure modes in semiconductor devices and employ systemic measures such as fail-safes, so that the equipment incorporating Renesas product does not cause bodily injury, fire or other consequential damage due to operation of the Renesas product.

5. This product is not designed to be radiation resistant.

6. No one is permitted to reproduce or duplicate, in any form, the whole or part of this document without written approval from Renesas.

7. Contact Renesas’s sales office for any questions regarding this document or Renesas semiconductor products.

Preface

Thank you for purchasing this user system interface cable (HS3834ECF61H) for the Renesas’s original microcomputer H8/300L series.

The HS3834ECF61H is a user system interface cable that connects an H8/300L series E6000 emulator (HS3L08EPI60H; hereinafter referred to as the emulator) to the IC socket for a FP-100A package for the H8/3834 series, H8/3814 series, or H8/3877 series MCU on the user system.

The H8/3834 series, H8/3814 series, and H8/3877 series MCUs can be emulated using the same user system interface cable by setting the MCU type switch (SW1). (For details, refer to item 4 in section 4, Verifying Operation.) i

Contents

Section 1 Configuration....................................................................................1

Section 2 Connection Procedures ......................................................................3

2.1 Connecting User System Interface Cable to Emulator Station ......................................... 3

2.2 Connecting User System Interface Cable to User System ................................................ 5

2.2.1 Installing IC Socket ............................................................................................. 5

2.2.2 Soldering IC Socket ............................................................................................. 5

2.2.3 Inserting Cable Head ........................................................................................... 5

2.2.4 Fastening Cable Head .......................................................................................... 6

2.2.5 Fastening Cable Body .......................................................................................... 8

2.3 Recommended Dimensions for User System Mount Pad ................................................. 9

2.4 Dimensions for User System Interface Cable Head.......................................................... 10

2.5 Resulting Dimensions after Connecting User System Interface Cable ............................. 11

Section 3 Installing the MCU to the User System.............................................12

Section 4 Verifying Operation...........................................................................13

Section 5 Notice ................................................................................................15

ii

Section 1 Configuration

CAUTION

Use an IC149-KS-11113-0 socket (manufactured by

YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100A

package IC socket on the user system.

Figure 1 shows the configuration of the HS3834ECF61H user system interface cable for the

FP-100A package.

Figure 1 HS3834ECF61H User System Interface Cable

1

Table 1 lists the HS3834ECF61H components. Please make sure you have all of these components when unpacking.

Table 1 HS3834ECF61H Components

No. Component

1 Cable body

6 Documentation

Quantity

1

3 IC socket

4 Socket cover

1

1

1

5 Screws (M2.5 x 11 mm) 2

1

Remarks

Flat cable

For the FP-100A package

For installing an FP-100A-packaged MCU

For fastening cable head (with two flat washers)

2

Section 2 Connection Procedures

2.1 Connecting User System Interface Cable to Emulator Station

WARNING

Observe the precautions listed below. Failure to do so

will result in a FIRE HAZARD and will damage the user

system and the emulator product or will result in

PERSONAL INJURY. The USER PROGRAM will be

LOST.

1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.

2. The user system interface cable dedicated to the emulator must be used.

To connect the cable body to the emulator station, follow the instructions below.

1. Make sure the user system and emulator station are turned off.

CAUTION

When connecting or removing the user system interface

cable, apply force only in the direction suitable for

connection or removal, while making sure not to bend or

twist the cable or connectors.

Otherwise, the connectors will be damaged.

2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket (figure 2).

3

Figure 2 Connecting User System Interface Cable to Emulator Station

4

2.2 Connecting User System Interface Cable to User System

WARNING

Always switch OFF the user system and the emulator

product before the USER SYSTEM INTERFACE CABLE

is connected to or removed from any part. Before

connecting, make sure that pin 1 on both sides are correctly

aligned. Failure to do so will result in a FIRE HAZARD and

will damage the user system and the emulator product or

will result in PERSONAL INJURY. The USER PROGRAM will

be LOST.

To connect the cable head to the user system, follow the instructions below.

2.2.1 Installing IC Socket

After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of the IC socket for an FP-100A package, and fasten it to the user system before soldering.

2.2.2 Soldering IC Socket

After fastening, solder the IC socket for an FP-100A package to the user system. Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets.

(Use slightly more solder than the MCU.)

2.2.3 Inserting Cable Head

CAUTION

Check the location of pin 1 before inserting.

Align pin 1 on the IC socket for an FP-100A package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3.

5

6

2.2.4 Fastening Cable Head

CAUTION

1. Use a Philips-type screwdriver whose head matches the screw head.

2. The tightening torque must be 0.098 N•m or less.

If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or a socket contact error may be caused by a crack in the socket solder.

3. If the emulator does not operate correctly, cracks might have occurred in the solder. Check conduction with a tester and re-solder the socket if necessary.

Fasten the user system interface cable head to the IC socket for an FP-100A package on the user system with the two screws (M2.5 x

11 mm; with two flat washers) provided. Each screw should be tightened a little at a time, alternating between the sides. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.

Figure 3 Connecting User System Interface Cable to User System

7

2.2.5 Fastening Cable Body

Connect the cable body to the cable head.

Figure 4 Fastening Cable Body

8

2.3 Recommended Dimensions for User System Mount Pad

Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-100A package (IC149-KS-11113-0: manufactured by YAMAICHI

ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad.

27.4 (min.)

21.4 (max.)

0.65 x 29 = 18.85 – 0.1

0.65 – 0.05

0.35

+ 0.1

- 0.05

Unit: mm

Figure 5 Recommended Dimensions for Mount Pad

9

2.4 Dimensions for User System Interface Cable Head

The dimensions for the user system interface cable head are shown in figure 6.

10

Figure 6 Dimensions for User System Interface Cable Head

2.5 Resulting Dimensions after Connecting User System Interface Cable

The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7.

Figure 7 Resulting Dimensions after Connecting User System Interface Cable

11

Section 3 Installing the MCU to the User System

CAUTION

1. Check the location of pin 1 before inserting.

2. The tightening torque must be 0.098 N•m or less.

If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or a socket contact error may be caused by a crack in the socket solder.

3. If the MCU does not operate correctly, cracks might have occurred in the solder. Check conduction with a tester and re-solder the IC socket if necessary.

Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as shown in figure 8. After inserting the MCU, put the socket cover on the MCU and the IC socket and fasten it with the four corner tabs.

12

Figure 8 Installing MCU to User System

Section 4 Verifying Operation

1. When using the H8/300L series E6000 emulator (HS3L08EPI60H), turn on the emulator according to the procedures described in the H8/300 Series E6000 Emulator User's Manual

(HS3008EPI60HE).

2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin

1.

3. The emulator connected to this user system interface cable supports two kinds of clock sources: an emulator internal clock and an external clock on the user system, for the MCU clock and subclock. For details, refer to the H8/300L Series E6000 Emulator User's Manual

(HS3008EPI60HE).

 To use the emulator internal clock

Select the clock in the emulator station as the system clock (

φ) and the subclock

(

φw), by using the CLOCK command (emulator command).

 To use the external clock on the user system as the system clock

Select target clock t2 with the CLOCK command (emulator command). Supply the external clock from the user system to the emulator by inputting the external clock from the OSC1 terminal on the cable head or connecting a crystal oscillator to the OSC1 and OSC2 terminals.

For details, refer to section 4, Clock Pulse Generator in the H8/3834 Series, H8/3814 Series,

H8/3877 Series Hardware Manual.

 To use the external clock on the user system as the subclock

Select target clock sub t with the CLOCK command (emulator command). Supply the external clock from the user system to the emulator. To input an external subclock from the user system, input clock pulses satisfying the specifications shown in figure 9 into the X1 terminal. The oscillator circuits on the user system interface cable cannot generate external subclock pulses by using the crystal oscillator connected to the user system.

13

Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input specifications.

R1 1 M

HCU04

HCU04

R2 270

To E6000 emulator

Vcc

0 V

OSC1 OSC2

0.8

0.3

Vcc

Vcc

55 ns max.

55 ns max.

0.8

Vcc

0.3

Vcc

System clock oscillator

Vcc: User System Vcc

(3.0 V to 5.0 V)

Subclock input specifications

Figure 9 System Clock Oscillator and Subclock Input Specifications

4. Select the MCU type by setting the MCU type switch (SW1) as follows before using the user system interface cable:

 For the H8/3834 series or H8/3814 series: Turn off the switch (to the 3834 side)

 For the H8/3877 series: Turn on the switch (to the 3876 side).

Figure 10 shows the allowable SW1 setting. Do not use any other setting.

SW1 SW1

3834 3876 3834 3876

OFF ON OFF ON

H8/3834series,

H8/3814 series

H8/3877 series

Figure 10 SW1 Setting

14

Section 5 Notice

1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket.

2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.

3. This user system interface cable is specifically designed for the HS3L08EPI60H emulator. Do not use this cable with any other emulator station.

4. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the user system interface cable.

5. While the emulator station is connected to the user system with the user system interface cable, force must not be applied to the cable head. Place the emulator station, user system interface cable, and user system as shown in the example in figure 11.

Figure 11 User System Interface Cable Location Example

6. The P1 short connector is used for testing. Do not remove the inserted jumper pin.

Figure 12 P1 Short Connector

15

advertisement

Key Features

  • Connects H8/300L series E6000 emulator to user system
  • Supports H8/3834, H8/3814, and H8/3877 series MCUs
  • Allows debugging and testing of user system
  • Provides emulator internal clock or external clock from user system
  • Includes socket cover for MCU installation

Frequently Answers and Questions

What is the purpose of the User System Interface Cable?
This cable provides a connection between an H8/300L series E6000 emulator (HS3L08EPI60H) and your user system for emulation development. It allows you to debug and test your system.
Which MCUs are supported by this cable?
The HS3834ECF61H cable supports the H8/3834 series, H8/3814 series, and H8/3877 series MCUs. You can select the MCU type using the MCU type switch (SW1) on the cable.
How do I connect the cable to the emulator station and user system?
Detailed instructions for connecting the cable to both the emulator station and user system are provided in the manual. Make sure to align pin 1 on both sides before connecting.
Can I use an external clock for the MCU?
Yes, you can supply an external clock from your user system to the emulator. The cable supports clocking via the OSC1 terminal or by connecting a crystal oscillator to the OSC1 and OSC2 terminals.
Is there a socket cover included?
Yes, a socket cover is included to secure the MCU after installation in the IC socket on the user system.

Related manuals

Download PDF

advertisement