IOTA ENGINEERING, L.L.C. DLS 15, DLS 30, DLS 45, DLS 55, DLS 75, DLS 90 Power Converter/Battery Charger Owner's Manual
The DLS 15, DLS 30, DLS 45, DLS 55, DLS 75, and DLS 90 Power Converter/Battery Chargers are designed to convert 120 volts of AC power to 13.6 volts of DC. They can handle up to the converter’s rated output current and will maintain battery charge, delivering their full-rated current when the battery’s capacity goes down. The DLS series can help ensure the longest possible life of the battery.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
DLS
SERIES
12-VOLT POWER CONVERTER/BATTERY CHARGER
OWNER’S MANUAL
Thank you for purchasing IOTA’s DLS Series Power Converter/Battery Charger. When utilized properly, your DLS Power
Converter/Battery Charger will provide years of dependable service. This Owner’s Manual contains important safety and operating instructions. READ ALL INSTRUCTIONS AND SAFETY PRECAUTIONS CAREFULLY BEFORE INSTALLING
AND OPERATING THE UNIT.
WARNING
Risk of SERIOUS INJURY OR DEATH
This unit is an electrical device. When working with this, or any electrical device, there exists the potential for
ELECTRICAL SHOCK, EXPLOSION and FIRE hazards.
Before using this equipment, READ AND UNDERSTAND the instructions, warnings, and safety precautions in this Owner’s
Manual. Failure to read and understand these instructions could result in SERIOUS INJURY or DEATH.
SAVE THESE INSTRUCTIONS
CAUTION
When working with the DLS unit, always observe the following guidelines:
• The DLS is designed for indoor use. Do not use outdoors.
• DO NOT expose the DLS unit to rain, snow, or other inclement weather.
• Do not mount the DLS in a zero clearance compartment or in compartments with flammable items such as gasoline or batteries.
• Do not mount the DLS in an area with the potential of dust, debris, or other foreign materials entering the vents of the DLS.
• Use of an attachment or device with the DLS not recommended by IOTA Engineering will void the warranty and may result in a risk of fire, electrical shock, or injury to persons.
• To reduce the risk of damage to the electric plug and cord, always pull by the plug and not the cord when disconnecting the unit.
• DO NOT operate the DLS with a damaged cord or plug.
• DO NOT operate the DLS if it has been dropped, received a sharp blow, or has been otherwise damaged in any way.
Take the DLS unit to a qualified service location.
• DO NOT disassemble the DLS unit. Take the DLS to a qualified service location when service or repair is required.
• To reduce the risk of electric shock, DISCONNECT the
DLS charger from ALL power sources before attempting any maintenance or cleaning. Turning off any electrical supply or load to the unit is not sufficient and will not reduce this risk.
• DO NOT use extension cords. Using an improper extension cord could result in a risk of fire and electric shock, and may result in property damage, personal injury or death.
DANGER
ELECTRICAL SHOCK HAZARD
THIS CHARGER IS AN ELECTRICAL
DEVICE THAT CAN SHOCK AND CAUSE
SERIOUS INJURY.
DO NOT CUT POWER CORDS.
DO NOT SUbmERGE IN WATER OR GET
THE CHARGER WET.
EXPLOSION HAZARD
UNSUPERVISED, INCOmPATIbLE, OR
DAmAGED bATTERIES CAN EXPLODE IF
USED WITH A CHARGER.
DO NOT ATTEmPT TO CHARGE DAmAGED
OR FROZEN bATTERIES.
USE THE CHARGER ONLY WITH bATTER-
IES OF RECOmmENDED VOLTAGE.
OPERATE THE CHARGER IN
WELL-VENTILATED AREAS ONLY.
WARNING
FIRE HAZARD
A CHARGER IS AN ELECTRICAL DEVICE
THAT EmITS HEAT AND CAN bURN.
DO NOT COVER THE CHARGER.
KEEP THE CHARGER AWAY FROm
COmbUSTIbLE mATERIALS.
DO NOT SmOKE OR USE ANY
OTHER SOURCE OF ELECTRICAL
SPARK OR FIRE WHEN OPERATING
THE CHARGER.
RISK OF EXPLOSIVE GASES
WORKING IN THE VICINITY OF LEAD-
ACID bATTERIES IS DANGEROUS. bATTERIES GENERATE EXPLOSIVE
GASES DURING NORmAL bATTERY
OPERATION. FOR THIS REASON, IT IS
OF UTmOST ImPORTANCE THAT YOU
FOLLOW THE INSTRUCTIONS WHEN
USING THE bATTERY CHARGER.
To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and review all Cautions and Warnings associated with these products.
PRODUCT DESCRIPTION
IOTA DLS Series Power Converter/Battery Chargers convert 120 volts nominal A.C. to 13.6 volts D.C. As a power supply, its tightly controlled regulation allows the user to operate any 12 volt nominal D.C. load up to the converter’s rated output current. As a battery charger, the converter will maintain the battery, delivering its full-rated current when the battery capacity falls sufficiently low. The voltage is set to deliver its maximum current for the necessary period of time that minimizes undue stress to the battery caused by heating of its cells. This helps to ensure the longest possible life of the battery. Over time, as the battery nears its full capacity, the converter will float-charge the battery to prevent self-discharge of its cells.
PROTECTION FEATURES
The IOTA Power Converters/Battery Chargers are designed with high quality components to help ensure years of continuous use. The unit is protected by multiple protection features for a long, trouble-free life.
1) Reverse Battery Polarity Protection. 2) Brown-Out In-
put Protection. 3) Over-Current Protection - cycle by cycle peak limiting as well as rated current limiting to maximize the life of the converter. 4) Over-Temperature Protection.
In addition, it is designed with a unique “proportional” fan control circuit. Fan speed is directly proportional to the converter’s internal ambient temperature. This enables the fan to turn on and off very slowly, minimizing unwanted fan-starting noise.
WARRANTY
The IOTA Power Converters/Battery Chargers are warranted from defects in materials or workmanship for two years from date of retail purchase, and limits the remedies to repair or replacement. This warranty is valid only in the continental United States and Canada. For complete warranty details, contact Customer Service or visit www.iotaengineering.com.
INSTALLATION GUIDELINES
mOUNTING LOCATION
The IOTA Power Converter/Battery Charger can be mounted in any position within an enclosed or interior compartment.
Provide sufficient air space to allow unrestricted airflow in and around the unit. Provide at least 4 ″ around the fan of the DLS to allow for proper air intake.
DO NOT mount the unit in a zero clearance compartment.
DO NOT mount the DLS in the same compartment with flammable items such as gasoline or batteries. There are no components within the DLS unit that, during normal operation, produce arcs or sparks. However, all electronic devices have some potential for generating sparks in the event of failure which can result in explosion or fire.
DO NOT mount the DLS in an area that has the potential of dust, debris, or other foreign materials to enter in through the
DLS vents.
DO NOT place the DLS directly above the battery; the gases from the battery can corrode and damage the DLS.
bATTERY CONNECTION
Before you connect the DLS to the battery, make sure that the
AC power cord is NOT plugged into an electrical outlet.
Disconnect the positive side of the battery before installation.
Connect the positive (red) and negative (black) terminal lugs to battery or load (lugs require a #2 square drive). Always use the proper size wire based on the amperage of the converter and the battery. When connecting to a battery, a breaker should be installed within 18 ″ of the battery, connecting the battery positive to the line side of the breaker, and the IOTA unit to the load side. Connect “Chassis Bonding Lug” on the IOTA unit to vehicle chassis or other grounding source. Refer to Illustration 1.
120 VOLT A.C. INPUT
Plug the unit A.C. input cord into an appropriate 120-volt 3-wire grounded source. Refer to Illustration 2 for specifications of the cord provided with your DLS unit. See the Technical Specifications Chart on page 4 for maximum current draw and required input voltages.
DO NOT USE EXTENSION CORDS - Using an improper extension cord could result in a risk of fire and electric shock, and may result in property damage, personal injury or death.
DO NOT OPERATE THE DLS WITH A DAMAGED CORD OR
PLUG. Have the cord or plug replaced immediately by qualified service personnel.
REVERSE POLARITY FUSES
The IOTA Battery Charger/Power Supply is protected against reverse polarity on the DC output. If a battery or the unit is hooked up incorrectly, the fuses will blow and can be easily replaced. Always use the same size and style fuse that came with the converter. To change the fuses, use a screwdriver to loosen the screws and remove the fuses. Always replace the fuses with the same type and rating. After inserting the new fuses, tighten the screws firmly. Apply 5 inch-pound maximum torque. DO NOT OVERTIGHTEN. Note: some
DLS models require only one fuse. For these units, a small fiberglass spacer may be used in the empty fuse slot to aid with tightening.
ILLUSTRATION 1 - DLS CONNECTIONS*
DLS SERIES m
ILLUSTRATION 2 - AC INPUT PLUG
DLS SERIES M
NEMA 5-15P PLUG
FOR 15A RECEPTACLE
DLS-75
DLS-75, DLS-90
NEMA 5-20P PLUG
FOR 20A RECEPTACLE
DLS-90
NEMA 5-15P PLUG
FOR 15A RECEPTACLE
*Actual component locations may vary depending on model.
CHARGE CONTROL
TWO-STEP VOLTAGE JACK
The two-step voltage jack allows switching from a long-term float voltage of 13.6vdc to a ‘high-stage’ voltage of 14.2vdc.
When the included dual voltage plug is inserted in the jack*, the voltage rises to 14.2vdc for occasional fast charging.
When the plug is removed, the voltage drops to 13.6vdc to reduce battery water loss. WARNING: To avoid battery damage, remove the Dual Voltage Plug when quick-
charging is complete. NOTE: If the unit is equipped with an internal IQ4 smart charger, two-step charging is not needed and the Dual Voltage Jack is disabled.
ILLUSTRATION 3 - DUAL VOLTAGE JACK
THE IQ4 LED INDICATOR
(ONLY ON IOTA mODELS WITH INTERNAL IQ4)
IOTA Models with an internal IQ4 smart-charger give the user the benefit of automatic Bulk, Absorption, and Float stage charging. This increases the charging capacity of the IOTA charger, decreases charge times and insures proper and safe battery charging without over-charging.
The green LED on the fan end of the unit will indicate which charging phase the IOTA unit is currently in. When the unit is first activated, the LED will flash as it reads the number of cells in the battery. The unit will then proceed directly to the Bulk charging or Float charging phase depending on the charge status of the battery. Use the LED CODE
TABLE for reference when checking the LED. Units that do not have an internal IQ4 smart-charger can easily install an external IQ4 that plugs into the available Dual Voltage
Jack. Contact Customer Service for more information.
Location of the Dual Voltage Jack may vary depending on model.
TECHNICAL SPECIFICATIONS CHART
RATINGS AND SPECIFICATIONS
DLS-15
SERIES m
13.6V (DC) DC Output Voltage (No Load) approx.
Output Voltage Tolerance (No Load)
Output Amperage, Max Continuous
Output Voltage (Full Load) approx.
Maximum Power Output, Continuous
Ripple and Noise
Input Voltage Range
Input Voltage Frequency
Maximum AC Current (@108Vac)
Typical Efficiency
Max Inrush Current, Single Cycle
Short Circuit Protection
Overload Protection
Line Regulation
Load Regulation
Fan Control
Thermal Protection
Working Temperature Range
Storage Temperature
Withstand Voltage (VDC) †
Approximate Dimensions
Weight
+ or - .7%
15 Amps
>13.4V (DC)
200 Watts
<50 mV rms
108 - 132 AC
47-63
3.7 Amps
>80%
30 Amps
Yes
>100%
100 mV rms
<1%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
9.7
″ x 6.7″ x 3.4″
5.0 lbs
DLS-30
SERIES m
13.6V (DC)
+ or - .7%
30 Amps
>13.4V (DC)
400 Watts
<50 mV rms
108 - 132 AC
47-63
7.3 Amps
>80%
30 Amps
Yes
>100%
100 mV rms
<1%
PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
1700/1700/500
9.7
″ x 6.7″ x 3.4″
5.0 lbs
*Unit is not UL Listed
DLS-45
SERIES m
13.6V (DC)
+ or - .7%
45 Amps
>13.4V (DC)
600 Watts
<50 mV rms
108 - 132 AC
47-63
11 Amps
>80%
30 Amps
Yes
>100%
100 mV rms
<1.5%
DLS-55
SERIES m
13.6V (DC)
DLS-75 DLS-90 *
+ or - .7%
55 Amps
>13.4V (DC)
750 Watts
<50 mV rms
108 - 132 AC
47-63
13.4 Amps
>80%
30 Amps
Yes
>100%
100 mV rms
<1.5%
13.6V (DC)
+ or - .7%
75 Amps
>13.4V (DC)
1000 Watts
<100 mV rms
108 - 132 AC
47-63
18.2 Amps
>80%
40 Amps
Yes
>100%
100 mV rms
<1.5%
13.6V (DC)
+ or - .7%
90 Amps
>13.4V (DC)
1200 Watts
<150 mV rms
108 - 132 AC
47-63
21.8 Amps**
>80%
40 Amps
Yes
>100%
100 mV rms
<1.5%
PROPORTIONAL PROPORTIONAL PROPORTIONAL PROPORTIONAL
YES
0° - 40° C
-20° to 80° C
YES
0° - 40° C
-20° to 80° C
YES
0° - 40° C
-20° to 80° C
YES
0° - 40° C
-20° to 80° C
1700/1700/500
9.7
″ x 6.7″ x 3.4″
5.0 lbs
**Requires 30A breaker
1700/1700/500
9.7
″ x 6.7″ x 3.4″
5.0 lbs
1700/1700/500
13 ″ x 6.5″ x 3.4″
7.8 lbs
1700/1700/500
13 ″ x 6.5″ x 3.4″
7.8 lbs
† Primary to Chassis/Primary to Secondary/Secondary to Chassis
Distributed By:
IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com
68357-000 REV 012512
DLS
SERIES
CONVERTISSEUR/CHARGEUR DE BATTERIE
GUIDE DE PROPRIÉTAIRE
Merci pour votre achat du Convertisseur/Chargeur de batterie de la série d’IOTA Engineering. Lorsqu’il est utilisé correctement, ce Convertisseur/Chargeur de Batterie DLS pourra fonctionner pendant plusieurs années. Ce Manuel du propriétaire contient d’importantes instructions de sécurité et de fonctionnement. VEUILLEZ LIRE TOUTES LES INSTRUCTIONS ET
LES PRÉCAUTIONS DE SÉCURITÉ ATTENTIVEMENT AVANT D’INSTALLER ET D’UTILISER L’UNITÉ.
AVERTISSEmENT
Risque de GRAVES bLESSURES OU DE mORT
Cette unité est un appareil électrique. Lors de son utilisation ou avec un quelconque autre appareil électrique, il existe des risques potentiels de CHOC ÉLECTRIQUE, D’EXPLOSION OU D’INCENDIE.
Avant d’utiliser cet équipement, veuillez LIRE ET COMPRENDRE les consignes, avertissements et précautions de sureté se trouvant dans le Manuel du Propriétaire.
La mauvaise lecture ou une mauvaise compréhension de ces consignes pourrait entraîner de GRAVES BLESSURES voire LA MORT.
SAUVEGARDER CES INSTRUCTIONS
ATTENTION
Lorsque vous travaillez avec l’unité DLS, veuillez respecter les directives ci-dessous:
• Le DLS est conçu pour une utilisation intérieure. Ne pas utiliser à l’extérieur.
• NE PAS exposer l’unité DLS à la pluie, neige ou autre intempérie.
• Ne pas monter le DLS dans un compartiment à tolérance zéro ou dans des compartiments avec des objets inflammables tels que de l’essence ou des batteries.
• Ne pas monter le DLS dans une zone où de la poussière, des débris ou autres matériaux parasites pourraient entrer dans les conduits du DLS.
• L’utilisation d’une attache ou d’un appareil avec le DLS n’est pas recommandée par IOTA Engineering qui annulera la garantie. Il y a également des risques d’incendie, de choc électrique ou de blessures sur personne.
• Afin de réduire le risque de dommage sur la prise et le fil
électrique, veuillez tirer sur la prise, et non le fil lorsque vous débranchez l’unité.
• NE PAS utiliser le DLS avec un fil ou une prise endommagée.
• NE PAS utiliser le DLS s’il est tombé, a reçu un coup ou a été endommagé d’une manière ou d’une autre. Amenez l’unité DLS auprès d’un endroit de service agréé.
• NE PAS démonter l’unité DSL. Amenez l’unité DLS auprès d’un endroit de service agréé lorsqu’un service ou une réparation est requise.
• Afin de réduire le risque de choc électrique, DÉBRANCHEZ le chargeur DLS de TOUTES les sources de courant avant d’effectuer tout nettoyage ou maintenance. Couper tout courant ou charge électrique vers l’unité n’est pas suffisant et ne réduira pas le risque.
• NE PAS utiliser de rallonge. L’utilisation d’une mauvaise rallonge pourrait résulter en un risque d’incendie ou un choc électrique et pourrait résulter endommager les biens, causer des blessures personnelles voir la mort.
DANGER
RISQUE DE CHOC ÉLECTRIQUE
CE CHARGEUR EST UN APPAREIL ÉLEC-
TRIQUE QUI PEUT CAUSER UN CHOC ET
DES bLESSURES GRAVES.
NE PAS COUPER LES FILS ÉLECTRIQUES.
NE PAS SUbmERGER D’EAU OU mOUILLER
LE CHARGEUR
RISQUE D’EXPLOSION
DES bATTERIES NON-SUPERVISÉES,
INCOmPATIbLES OU ENDOmmAGÉES PEU-
VENT EXPLOSER SI ELLES SONT UTILI-
SÉES AVEC UN CHARGEUR.
NE PAS ESSAYER DE CHARGER DES bAT-
TERIES ENDOmmAGÉES OU GELÉES.
UTILISER SEULEmENT LE CHARGEUR
AVEC DES bATTERIES AU VOLTAGE RE-
COmmANDÉ.
UTILISER LE CHARGEUR SEULEmENT
DANS DES ZONES bIEN VENTILÉES.
AVERTISSEmENT
RISQUE D’INCENDIE
UN CHARGEUR EST UN APPAREIL ÉLEC-
TRIQUE QUI ÉmET DE LA CHALEUR ET
PEUT bRULER.
NE PAS COUVRIR LE CHARGEUR.
CONSERVER LE CHARGEUR HORS DE POR-
TÉE DE mATÉRIAUX COmbUSTIbLES.
NE PAS FUmER OU N’UTILISER AUCUNE
AUTRE SOURCE D’ÉTINCELLE ÉLECTRIQUE
OU DE FEU LORSQUE VOUS UTILISEZ LE
CHARGEUR.
RISQUE DE GAZ EXPLOSIFS
TRAVAILLER AVEC DES bATTERIES PRINCI-
PALEmENT EN ACIDE EST DANGEREUX. LES bATTERIES GÉNÈRENT DES GAZ EXPLOSIFS
DURANT LE FONCTIONNEmENT NORmAL DE
LA bATTERIE. DE CE FAIT, IL EST EXTRÈmEmENT ImPORTANT QUE VOUS SUIVIEZ LES
INSTRUCTIONS LORSQUE VOUS UTILISEZ LE
CHARGEUR DE bATTERIE.
Afin de réduire le risque d’explosion de la batterie, veuillez suivre ces instructions ainsi que celles publiées par le fabriquant de batterie et veuillez revoir tous les Avertissements et Dangers associés à ces produits.
INSERT
advertisement
Key Features
- Provides years of dependable service
- Converts 120 volts nominal A.C. to 13.6 volts D.C.
- Tightly controlled regulation
- Maintains battery, delivering full-rated current
- Float-charge battery to prevent self-discharge
- Protected against reverse battery polarity
- Brown-Out Input Protection
- Over-Current Protection