- Industrial & lab equipment
- Measuring, testing & control
- Omega
- OM-CP-pHTemp2000
- Owner's manual
- 5 Pages
Omega OM-CP-pHTemp2000 Owner Manual
Omega OM-CP-pHTemp2000 is a pH and temperature data logger with a large LCD display. The device allows to monitor current pH and temperature readings, as well as minimum, maximum and average statistics. Its convenient design enables users to access critical data quickly and easily. The backlight feature enhances visibility in low-light conditions, ensuring that users can stay informed even in challenging environments.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
MADE IN
Shop online at
omega.com e-mail: [email protected]
For latest product manuals: omegamanual.info
OM-CP-pHTemp2000
pH and Temperature Data Logger with LCD
OM-CP-pHTemp2000
Product Notes
The OM-CP-pHTemp2000 is a pH and temperature data logger with LCD display.
The convenient LCD provides access to the current pH and temperature readings, as well as minimum, maximum and average statistics.
Backlight
The backlight uses up a significant amount of battery life, it can be configured to auto shut-off when not in use. Refer to the manual for more details.
Using the OM-CP-pHTemp2000
1. The pH electrode should have a BNC output connection, or an appropriate
adapter. Select a probe with an output impedance less than 300 megaohms
at the desired temperature.
2. The temperature probe must be a 100 ohm platinum RTD, in the standard 2-,
3- or 4-wire configuration. The OM-CP-pHTemp2000 is designed to achieve
exceptional accuracy with the 4-wire probe, but will still yield measurements
better than required for a pH-measurement with the 2- or 3-wire probes.
3. Insure that the probe you select can be connected to the OM-CP-pHTemp2000
RTD input by selecting a probe with lead wires, or by attaching an adapter
that will allow you to connect wire leads to the probe.
4. Connect the probes to the data logger.
5. Refer to the description of your pH probe for a calibration procedure.
100 Ohm, 2 or 4 wire RTD probes are recommended for the most accurate performance. Most 100 Ohm, 3 wire RTD probes will work, but Omega cannot guarantee the accuracy. To determine whether or not the 3-wire RTD probe will work, the resistance between the two same colored wires should be less than 1
Ohm.
(Note: Please contact the manufacturer of the RTD probe for questions on the resistance)
Device Maintenance
Battery Replacement
Materials:
3/32” HEX Driver (Allen Key) and a Replacement Battery (OM-CP-BAT103)
- Remove the back cover from the device by unscrewing the four screws.
- Remove the battery from its compartment and unsnap it from the connector.
- Snap the new battery into the terminals and verify it is secure.
- Replace the cover taking care not to pinch the wires. Screw the enclosure
back together securely.
Note: Be sure not to over tighten the screws or strip the threads.
Quick Start Manual
Installation Guide
Installing the Interface cable
- OM-CP-IFC200: Refer to the “Quick Start Guide” included in the package.
Installing the software
Insert the Software CD in the CD Drive. If the autorun does not appear, locate the drive on the computer and double click Autorun.exe. Follow the instructions in the Wizard.
Connecting the data logger
- Once the software is installed and running, plug the interface cable into the
data logger.
- Click the Communication Menu, then Auto Configure Port.
- After a moment, a box will appear stating that a device has been found.
- Click OK. The Device Status box will appear. Click OK.
- At this point, communications have been configured for your logger. These
settings can be found under the Communication Menu.
Note: For additional installation instructions refer to your “Data Logger & Software Operating Manual”.
Device Operation
Starting the data logger
- Click Device Menu then Start Device.
- Choose the desired start method.
- Choose the start parameters by selecting a Reading Rate suitable for your
application.
- Enter in any other desired parameters and click Start.
- A box will appear stating the data logger has been started. Click OK.
- Disconnect the data logger from the interface cable and place it in the
environment to measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped.
At this point the device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. This will offload all recorded
data onto the PC.
Part Number pH input Connection pH Range pH Resolution
Calibrated Accuracy
Temperature Sensor
Temperature Range
Temperature Resolution
Calibrated Accuracy
Memory
Sample Rate
Required Interface Package
Baud Rate
Typical Battery Life
Operating Environment
Material
Dimensions
Approvals
OM-CP-pHTemp2000
Female BNC jack
-2.00 to +16.00pH
0.01pH (0.1mV)
+0.01pH
2, 3, or 4 wire 100Ω platinum RTD
-40 to +110°C
0.01°C
+0.15°C @ 25°C Ambient
131,071/channel
2 seconds to 24 hours
OM-CP-IFC200
115,200
1 year with display off, 30 days with continuous LCD and no backlight
–5 to +50°C, 0 to 95%RH (non-condensing)
Black Anodized Aluminum
4.8” x 3.3” x 1.25” (122mm x 84mm x 32mm)
CE
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT,
CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE.
BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 60°C (140°F).
OMEGAnet ® Online Service Internet e-mail omega.com [email protected]
Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
Stamford, CT 06907-0047
Toll-Free: 1-800-826-6342 Tel: (203) 359-1660
FAX: (203) 359-7700 e-mail: [email protected]
Canada: 976 Bergar
Laval (Quebec), H7L 5A1 Canada
Toll-Free: 1-800-826-6342 TEL: (514) 856-6928
FAX: (514) 856-6886 e-mail: [email protected]
For immediate technical or application assistance:
U.S.A. and Sales Service: 1-800-826-6342/1-800-TC-OMEGA ®
Canada: Customer Service: 1-800-622-2378/1-800-622-BEST ®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN ®
Mexico/ En Español: 001 (203) 359-7803 FAX: 001 (203) 359-7807
Latin America [email protected] e-mail:[email protected]
Servicing Europe:
Benelux: Managed by the United Kingdom Office
Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21
FAX: +31 20 643 46 43 e-mail: [email protected]
Czech Frystatska 184
Republic: 733 01 Karviná, Czech Republic
Toll-Free: 0800-1-66342 TEL: +420-59-6311899
FAX: +420-59-6311114 e-mail: [email protected]
France: Managed by the United Kingdom Office
Toll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00
FAX: +33 (0) 130 57 54 27 e-mail: [email protected]
Germany/ Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Austria Toll-Free: 0800 6397678 TEL: +49 (0) 7056 9398-0
FAX: +49 (0) 7056 9398-29 e-mail: [email protected]
United OMEGA Engineering Ltd.
Kingdom: One Omega Drive, River Bend Technology Centre, Northbank
ISO 9001 Irlam, Manchester M44 5BD United Kingdom
Toll-Free: 0800-488-488 TEL: +44 (0) 161 777-6611
FAX: +44 (0) 161 777-6622 e-mail: [email protected]
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, human applications.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 61 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal five (5) year product
warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an
Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY
KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY
WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION
OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR
21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY
PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER
SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product was
PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative to
the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2011 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
MQS-5034/1011
advertisement
Key Features
- Simultaneously measures and records pH and temperature
- Backlit LCD display for easy viewing
- Memory capacity of 131,071 readings per channel
- Adjustable sampling rate from 2 seconds to 24 hours
- Compact and portable design for convenient use
- Battery life of up to 1 year with display off
- Compatible with a variety of pH and temperature probes
- Automatic data offload to PC for analysis and storage
- User-friendly software for data management and graphing