Aero Mist Professional Misting System 52500 Installation instructions

Aero Mist Professional Misting System 52500 Installation instructions

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Aero Mist Professional Misting System 52500 Installation instructions | Manualzz

LIMITED WARRANTY

Aeromist, Inc. shall warrant the components of the Professional Misting System

(Model 52500) to be free of defects in workmanship for five years. Maintenance items are not warrantable including nozzles and filters. No warranty of merchantability or other warranty, expressed or implied, is made.

Liability for, and the exclusive remedy for, defective materials or workmanship, is limited to the replacement or repair of defective products. This warranty applies only to the original purchaser of the system and is not transferable. Any parts found to be defective will be replaced at no charge. All parts must be returned to Aeromist, Inc., freight pre-paid by customer, and will be returned to customer by Aeromist, Inc., freight collect.

This warranty specifically excludes the following: Failure of parts due to damage by accident, fire, freezing, chemicals, improper installation, or unusual characteristics of water supply, such as mineral and calcium buildup.

This warranty covers parts only. Any costs incurred due to replacement or repair is the responsibility of the buyer and not covered under warranty.

INSTALLATION INSTRUCTIONS

3702 E Roeser Rd, Ste 1, Phoenix, AZ 85040

(602) 454-8900 www.aeromist.com

���������������������������

������������������� ����������������������������������� ��������������������������� ����������������������

���������������������������

�������������������

��������������������������

�����������������������

�������������������

TOOLS REQUIRED

Tape Measure

Screwdriver

Power Drill with 1/4" Bit (if using anchors)

Tubing Cutter (if customizing length)

5/8" Open-End Wrench

9/16" Open-End Wrench

LIST OF ALL ENCLOSED PARTS

QTY PART NO DESCRIPTION

1 52505 Sediment Filter

2 52519 Pre-Fabricated Misting Line (6' section)

2 52516 Flexible Nylon Tube (6' section)

6 52502 .014 Misting Nozzle

1 52511 Brass Elbow

2 52510 Brass Union

1 52513 Brass End Plug

10 52509 Vinyl-Coated Clamp, Screw and Anchor

INSTALLATION INSTRUCTIONS

1. Start by measuring the length of your patio perimeter (or perimeter of the area to be misted). Proper installation of your new Aeromist Professional

Misting System requires mounting the Pre-Fabricated Misting Line

(52519) on the bottom outside edge of the fascia, header or beam of patio perimeter. It is important to mount the line along the bottom edge, to prevent mist from spraying on structure. This installation will create a curtain of mist around your patio or misted area and provide maximum cooling.

The Aeromist Extension Kit (52501) extends your system by 6 ft. Add multiple extension kits to custom fi t a misting system to your patio or misted area mist up to 150 ft (more with optional pump). See the enclosed accessories brochure or go to www.aeromist.com for a sample of additional accessories and upgrades available including high-pressure pumps for increasing your misting system’s cooling performance and length.

2. Start installation by connecting Flexible Nylon Tube (52516) to outlet compression fi tting on the Sediment Filter (52505). Finger tighten brass fi tting, then insert tubing until it bottoms out in fi tting. Complete seal with one wrench turn of fi tting. Use Vinyl-Coated Clamps, Screws And

Anchors (52509) to secure nylon tubing and fi lter to the side of the structure. Use Brass Union (52510) to connect additional tubing.

3. Use Brass Elbow (52511) to connect Pre-Fabricated Misting Line

(52519) to Flexible Nylon Tube (52516), secure Pre-Fabricated

Misting Line (52519) to the bottom outside edge of fascia, header or beam with Vinyl-Coated Clamps, Screws And Anchors (52509). If necessary, cut the Pre-Fabricated Misting Line (52519) with a tubing cutter. Never use a saw to cut copper tubing, this will leave burrs and prevent the compression joints from sliding over the tubing. Space clamps on

Pre-Fabricated Misting Line (52519) 24" apart. Use Brass Union

(52510) to join sections of Pre-Fabricated Misting Line (52519).

Terminate system with Brass End Plug (52513).

4. Connect garden hose to inlet of Sediment Filter (52505) and fl ush system for several minutes before inserting nozzles. While system is fl ushing start inserting the .014 Misting Nozzles (52502) nozzles nearest the fi lter fi rst. Shut water off to insert last nozzle. Caution: hand-tighten only. Never use pliers to tighten nozzles.

MAINTENANCE

• When turning the misting system off, it is benefi cial to drain the water out of the line by disconnecting the garden hose at the fi lter. This will help eliminate mineral buildup.

• Nozzles require cleaning or replacement periodically. Clean nozzles by soaking in vinegar or calcium removal product overnight.

• Replace fi lter annually, water conditions may require replacement sooner.

• Winterize your misting system by removing all nozzles. Be sure all water is drained from misting lines. This will prevent water from freezing and damaging the mist line. For summer season start-up, follow Step 4 in the

Installation Instructions.

Note: Misting system is intended for outdoor use only.