IEC

IEC
Shenzhen Anbotek Compliance Laboratory Limited
Page 1 of 44 Report No. R011508965S
IEC REPORT
Azlan logistics limited
PAIR 60W ACTIVE CEILING LOUD SPEAKERS
Model: CS-1600P
Prepared For
: Azlan logistics limited
Redwood 2, Chineham Business Park, Crockford Lane,
Basingstoke, Hampshire, RG248WQ, United Kingdom
Prepared By
: Shenzhen Anbotek Compliance Laboratory Limited
1/F., Building 1, SEC Industrial Park, No.0409 Qianhai Road,
Nanshan District, Shenzhen, Guangdong, China
Tel:
Fax:
(86)755-26066544
(86)755-26014772
Date of Test:
Sept. 01, 2015 to Oct. 12, 2015
Date of Report:
Oct. 12, 2015
Report Number:
R011508965S
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 3 of 44 Report No. R011508965S
Particulars: test item vs. test requirements
Equipment mobility·······························································: Equipment for building-in
Operating condition······························································: Continuous operation
Tested for IT power systems·············································· : N.A.
IT testing, phase-phase voltage (V)·································· : N.A.
Class of equipment······························································ : N.A.
Protection against ingress of water··································· : IPX0
Possible test case verdicts
-test case does not apply to the test object····················· : N (N.A.)
-test object does meet the requirement···························· : P (Pass)
-test object does not meet the requirement····················· : F (Fail)
Testing
Date of receipt of test item··················································: Sept. 01, 2015
Data of performance of test················································ : Sept. 01, 2015 to Oct. 12, 2015
General remarks
"(See remark #)" refers to a remark appended to the report.
"(See appended table)" refers to a table appended to the report.
Throughout this report a dot is used as the decimal separator.
The test results presented in this report relate only to the object tested.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
Procedure deviation
N.A.
Comments
N.A.
General product information
1. The enclosures fixed together by screws and mechanical fixing.
2. Clearance was evaluated for altitude up to 2000m above sea level.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 4 of 44 Report No. R011508965S
Copy of marking plate(s)
PAIR 60W ACTIVE CEILING LOUD
SPEAKERS
Model: CS-1600P
Rating: 24V
, 2.5A, 60W
Azlan logistics limited
Made in China
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 5 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
3
General requirements
Safety class of the apparatus ········································· :
4
General conditions of tests
4.1.4
Ventilation instructions require the use of the test box
5
Marking and instructions
5.1
Result - Remark
Verdict
--
Neither class Ⅰ equipment
nor class Ⅱ equipment
P
-According to user’s manual
P
--
Comprehensible and easily discernible
Compliance checked
P
Permanent durability against water and petroleum
spirit
Slight rubbing by hand with
a water soaked cloth and
with a petroleum soaked
cloth for 15s each
The printed markings were
still legible
P
a) Identification, maker····················································· : Azlan logistics limited.
P
b) Model number or type reference································ : CS-1600P
P
c) Class II symbol if applicable········································ : Not Class Ⅱ apparatus
N
d) Nature of supply··························································· :
P
e) Rated supply voltage··················································· : 24V
P
f) Mains frequency if safety dependant·························· :
N
g) Rated current or power consumption for apparatus 2.5A
supplied by supply apparatus for general use···············:
P
Measured current or power consumption······················ :
P
Deviation % (max 10%)··················································· :
P
a) Earth terminal································································:
N
b) Hazardous live terminals············································· : No hazardous live terminals
N
c) Markings on supply output terminals························· : No such terminals
N
5.3
Use of triangle with exclamation mark
Used in the circuits
P
5.4
Instructions for use
Given English language
P
5.4.1
a) Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled with
liquid, etc.
5.2
b) Hazardous live terminals, instructions for wiring
N
No hazardous live
terminals
N
c) Instructions for replacing lithium battery
N
d) Class I earth connection warning
N
e) Instructions for multimedia system connection
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 6 of 44 Report No. R011508965S
IEC 60065
Clause
5.4.2
Requirement  Test
Result - Remark
Verdict
f) Special stability warning for attachment of the
apparatus to the floor/wall
N
g) Warning: battery exposure to heat
P
h) Warning: protective film on CRT face
N
a-b) Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
N
c) Instructions for permanently connected equipment
Not permanently connected
equipment
N
Marking, signal lamps or similar for completely
disconnection from the mains
No such parts
N
6
Hazardous radiations
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
-No ionizing radiation
N
Ionizing radiation under fault condition
N
Laser radiation, emission limits to IEC 60825-1:2007
N
Emission limits under fault conditions
N
7
Heating under normal operating conditions
--
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
7.1.4
Temperature rise of windings
(see appended table 7.1)
N
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150 oC
N
8
Constructional requirements with regard to the protection against electric
shock
--
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
N
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
6.2
N
No such components are
replaced by hand
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 7 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
8.4
No risk of electric shock from accessible parts or from
parts rendered accessible following the removal of a
cover which can be removed by hand
N
8.5
Class I equipment
N
Basic insulation between hazardous live parts and
earthed accessible parts
N
Resistors bridging basic insulation complying with
14.1 a)
N
Capacitors bridging basic insulation complying with
14.2.1 a)
N
Protective earthing terminal
N
8.6
Class II equipment and Class II constructions within
Class I equipment
Result - Remark
Only SELV circuit within the
EUT
Verdict
--
Double or reinforced insulation between hazardous
live parts and accessible parts
N
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
N
Basic insulation bridged by components complying
with 14.3.4.3
N
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
N
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
N
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
N
8.7
This clause is void
--
8.8
Basic or supplementary insulation > 0,4 mm (mm)······ :
N
Reinforced insulation > 0,4 mm (mm) ··························· :
N
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
N
Basic or supplementary insulation, at least two layers,
each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
N
Reinforced insulation, two layers each of which meet
10.3
N
Reinforced insulation, three layers any two which
meet 10.3
N
8.9
Adequate insulation between internal wiring
hazardous live conductors and accessible parts
Only SELV circuits within
the EUT
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 8 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
8.10
Double insulation between conductors connected to
the mains and accessible parts.
Only SELV circuits within
the EUT
Verdict
N
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
N
Detaching of wires
N
No undue reduction of creepages or clearance
distances if wires become detached
N
Vibration test carried out·················································· :
N
8.12
This clause is void
--
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
N
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
N
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
N
8.16
Only special supply equipment can be used
N
8.17
Insulated winding wire without additional interleaved
insulation
N
8.18
Endurance test as required by 8.17
N
8.19
Disconnection from the mains
N
8.19.1
Disconnect device
N
All-pole switch or circuit breaker with >3mm contact
separation
N
8.19.2
Mains switch ON indication
N
8.20
Switch not fitted in the mains cord
N
8.21
Bridging components comply with clause 14
N
8.22
Non-separable thin sheet material
N
9
Electric shock hazard under normal operating conditions
--
9.1
Testing on the outside
N
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
9.1.1.1
a) Open circuit voltages
N
b) Touch current measured from terminal devices
using the network in annex D ········································· :
N
c) Discharge not exceeding 45 μC
N
d) Energy of discharge not exceeding 350 mJ
N
Test with test finger and test probe
N
8.11
9.1.1.2
No high voltage
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 9 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
9.1.2
No hazardous live shafts of knobs, handles or levers
N
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
N
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
N
Terminal devices tested with 1 mm x 100 mm straight
wire (1 N); test probe D of IEC 61032
N
9.1.5
Pre- set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
N
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s ························· :
N
If C is not greater than 0,1 μF no test needed
N
9.1.7
Resistant to external force
Result - Remark
Only SELV circuits within
the EUT
Verdict
N
a) Test probe 11 of IEC 61032 for 10 s (50 N)
N
b) Test hook of fig. 4 for 10 s (20 N)
N
c) 30 mm diameter test tool for 5 s (100 or 250 N)·······:
N
9.2
No hazard after removing a cover by hand
N
10
Insulation requirements
--
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ···········································································:
N
10.2
Humidity treatment 48 h or 120 h ·································· : 48h, 30℃, 93%
P
10.3
Insulation resistance and dielectric strength between
mains terminals
N
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
N
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
N
11
Fault conditions
--
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
No fire hazard
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
P
Shenzhen Anbotek Compliance Laboratory Limited
Page 10 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Flames extinguish within 10 seconds
No flames
Verdict
P
No hazard from softening solder
P
Soldered terminations not used as protective
mechanism
P
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
(see appended table 11.2)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for max.
5 min
N
a) Temperature rise of printed circuit boards (PCB) to
20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm2
N
b) Temperature rise of printed circuit boards (PCB) to
20.1.3 up to 300K for an area not greater than 2 cm2
for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
N
Class I protective earthing maintained
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
(see appended table 11.2)
P
11.2.5
Temperature rise of windings
(see appended table 11.2)
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5 shall not exceed the limits in table 3,
item e), “Fault conditions”
P
12
Mechanical strength
--
12.1
Complete apparatus
Checked by the tests of
12.1.1 to 12.1.5
--
12.1.1
Bump test where mass >7 kg
Less then 7kg
N
12.1.2
Vibration test
30mins, no damaged
P
12.1.3
Impact hammer test
P
Steel ball test
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg
1m, 3 times
P
12.1.5
Thermoplastic enclosures stress relief test
Not plastic enclosures
N
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
No drawers
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 11 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
12.5
Antenna coaxial sockets providing isolation
Coaxial socket without
isolation function
P
12.6
Telescoping or rod antennas construction
No hazards
N
12.6.1
Telescoping or rod antennas securement
Ditto
N
13
Clearance and creepage distances
13.1
Clearances in accordance with 13.3
Verdict
-Only SELV circuits within
the EUT
N
Creepage distances in accordance with 13.4
N
13.2
Determination of operating voltage
N
13.3
Clearances
N
13.3.1
General
N
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9
N
13.3.3
Circuits not conductively connected to the mains
comply with table 10
N
13.3.4
Measurement of transient voltages
N
13.4
Creepage distances
N
Creepage distances greater than table 11 minimum
values
N
13.5
Printed boards
N
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N
13.5.2
Type B coated printed circuit boards complying with
IEC 60664- 3 (basic insulation only)
N
13.6
Conductive parts along uncemented joints clearances
and creepage distances comply with 13.3 and 13.4
N
Conductive parts along reliably cemented joints
comply with 8.8
N
Temperature cycle test and dielectric strength test
N
13.7
Enclosed, enveloped or hermetically sealed parts not
conductively connected to the mains, clearances and
creepage distances as in table 12
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
N
14
Components
--
14.1
Resistors
No such resistor
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 12 of 44 Report No. R011508965S
IEC 60065
Clause
14.2
Requirement  Test
Result - Remark
Verdict
a) Resistors between hazardous live parts and
accessible metal parts
No such resistor
N
b) Resistors, other than between hazardous live parts Ditto
and accessible parts
N
Resistors separately approved ·······································:
N
Capacitors and RC units
N
Capacitors separately approved
No such capacitor
N
14.2.1
Y capacitors tested to IEC 60384- 14, 2nd edition ········ :
N
14.2.2
X capacitors tested to IEC 60384- 14, 2nd edition ········ :
N
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ····························· :
N
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384- 1, 4.38 category B or better ·························:
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ························································· :
N
Shielded by a barrier acc. to 20.1.4/ table 21 or metal :
N
Inductors and windings
N
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
--
Transformers and inductors marked with
manufacturer's name and type ·······································:
N
Transformers and inductors separately approved ······· :
N
General
N
Insulation material complies with clause 20.1.4
N
14.3.3
Constructional requirements
N
14.3.3.1
Clearances and creepage distances comply with
clause 13
N
14.3.3.2
Transformers meet the constructional requirements
N
14.3.4
Separation between windings
N
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
N
Coil formers and partition walls > 0,4 mm
N
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of 14.3.4.2
are met
N
14.3.4.3
Separating transformers with at least basic insulation
N
14.3
14.3.1
14.3.2
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 13 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
N
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
N
Coil formers and partition walls > 0,4 mm
N
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N
Winding wires connected to protective earth have
adequate current-carrying capacity
N
High voltage components
--
14.3.5.2
14.4
High- voltage components and assemblies: U > 4 kV
(peak) separately approved
Result - Remark
No high voltage
components used
Verdict
N
Component meets category V-1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
N
14.4.2
High voltage assemblies and other parts tested as
part of the submission
N
14.5
Protective devices
--
Protective devices used within their ratings
No such device
N
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
N
a) Thermal cut-outs separately approved
N
b) Thermal cut-outs tested as part of the submission
N
a) Thermal links separately approved
N
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
N
14.5.2.1
Fuse-links in the mains circuit according to IEC 60127
N
14.5.2.2
Correct marking of fuse-links adjacent to holder ········· :
N
14.5.2.3
Not possible to connect fuses in parallel ·······················:
N
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ················:
N
14.5.3
PTC- S thermistors comply with IEC 60730-1:2007
14.5.1.1
14.5.1.2
14.5.4
No such device
N
PTC- S devices (15 W) category V-1 or better
N
Circuit protectors have adequate breaking capacity
and their position is correctly marked
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 14 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Verdict
14.6
Switches
No such device
--
14.6.1 a)
Separate testing to IEC 61058-1 including:
N
-10 000 operations
-Normal pollution suitability
-Resistance to heat and fire level 3
-Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
14.6.1 b)
Tested in the apparatus:
--
Switch controlling > 0.2A with open contact voltage >
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact voltage <
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in
annex G, G.1.1
N
Switch controlling < 0.2A with open contact voltage >
35 V (peak)/24 V dc complying with 14.6.4 and V-0 in
annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-1
subclause 13.1 and has making/breaking action
independent of speed of actuation
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-1
subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
N
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
N
Socket outlet current marking correct
14.7
Safety interlocks
Safety interlocks to 2.8 of IEC 60950-1
14.8
No socket outlet used
-No safety interlocks used
Voltage setting devices and the like
Voltage setting device not likely to be changed
accidentally
N
N
--
No voltage setting devices
used
N
14.9
Motors
--
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
See sub-clause 14.9
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 15 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
N
14.10
Batteries
--
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
N
14.10.2
No possibility of recharging non-rechargeable
batteries
N
14.10.3
Recharging currents and times within manufacturers
limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
N
14.10.4
Battery mould stress relief
N
14.10.5
Battery drop test
N
14.11
Optocouplers
--
a) Optocouplers comply with 13.6 (jointed insulation)
and N.2.1
N
b) Comply with IEC 60747-5-5:2007
N
Alternative to a) and b) optocoupler comply with 13.8
N
a) Comply with 13.6 (jointed insulation) and N.2.1
N
Surge suppression varistors
--
14.12
Comply with IEC 61051-2
Result - Remark
No surge suppression
varistors used
Verdict
N
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
N
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
N
15
Terminals
--
15.1
Plugs and sockets
--
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard
N
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
N
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 16 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket- outlets
Result - Remark
Verdict
--
No such outlet
No risk of insertion into audio- or video- outlets
marked with the symbol of 5.2
N
N
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets
No such devices provided
15.2
Provision for protective earthing
--
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within equipment
N
Protective earth conductors correctly coloured
N
Equipment with non-detachable mains cord provided
with separate protective earth terminal near mains
input
N
Protective earth terminal resistant to corrosion
N
Earth resistance test: < 0,1  at 25 A ·························· :
N
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
--
15.3.1
Adequate terminals for connection of permanent
wiring
N
15.3.2
Reliable connection of non-detachable cords:
N
Not soldered to conductors of a printed circuit board
N
Adequate clearances and creepage distances
between connections should a wire break away
N
Wire secured by additional means to the conductor
N
15.3.3
Screws and nuts clamping conductors have adequate
threads: ISO 261, ISO 262 or similar
N
15.3.4
Soldered conductors wrapped around terminal prior to
soldering or held in place by additional means
N
Clamping of conductor and insulation if not soldered
or held by screws
N
15.3.5
Terminals allow connection of appropriate crosssectional area of conductors, for the rated current of
the equipment
N
15.3.6
Terminals to 15.3.3 have sizes required by table 16
N
15.3.7
Terminals clamp conductors between metal and have
adequate pressure
N
Terminals designed to avoid conductor slipping out
when tightened or loosened
N
Terminals adequately fixed to avoid loosening when
the clamping is tightened or loosened and stress on
internal wiring is avoided
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 17 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
15.3.8
Terminals carrying a current more than 0,2 A: contact
pressure not transmitted by insulating material except
ceramic
N
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
N
Terminals located and shielded: test with 8 mm strand
N
15.4
Devices forming a part of the mains plug
--
15.4.1
No undue strain on mains socket-outlets
N
15.4.2
Device complies with standard for dimensions of
mains plugs
N
15.4.3
Device has adequate mechanical strength (tests a, b,
c)
N
16
External flexible cords
--
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic rubber
cords ··················································································:
N
Non-detachable cords for Class I have green/yellow
core for protective earth
N
16.2
Mains cords conductors have adequate crosssectional area for rated current consumption of the
equipment
N
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of equipment
used in combination and carrying hazardous live
voltages, have adequate dielectric strength
N
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of IEC 60227- 2)
N
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N
16.5
Adequate strain relief on external flexible cords
N
Not possible to push cord back into equipment
N
Strain relief device unlikely to damage flexible cord
N
For mains cords of Class I equipment, hazardous live
conductors become taut before earth conductor
N
16.6
Apertures for external flexible cord: no risk of damage
to the cord during assembly or movement in use
N
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet to
IEC 60320- 1
N
Result - Remark
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
Shenzhen Anbotek Compliance Laboratory Limited
Page 18 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Verdict
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
N
17
Electrical connections and mechanical fixings
--
17.1
Torque test to table 20
P
- screws into metal: 5 times
N
- screws into non-metallic material: 10 times
P
17.2
Correct introduction into female threads in nonmetallic material
P
17.3
Cover fixing screws: captive
N
Non-captive fixing screws: no hazard when replaced
by a screw whose length is 10 times its diameter
No hazard when replaced
by a screw whose length is
10 times its diameter
P
17.4
No loosening of conductive parts carrying a
current > 0,2 A
No such parts
N
17.5
Contact pressure not transmitted through plastic other No such parts
than ceramic for connections carrying a
current > 0,2 A
N
17.6
Stranded conductors of flexible supply cords carrying
a current > 0,2 A with screw terminals not
consolidated by solder
No such parts
N
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
Cover fixed with screws
P
17.8
Fixing devices for detachable legs or stands provided
N
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
N
18
Mechanical strength of picture tubes and protection against the effects of
implosion
--
Picture tube separately approved to IEC 61965..... :
N
No picture tube used
Picture tube separately approved to 18.1 ····················· :
N
Picture tubes >16 cm intrinsically protected
N
Non-intrinsically protected tubes >16 cm used with
protective screen
N
Protective film as part of implosion protection: edges
covered by enclosure
N
18.2
Non-intrinsically protected tubes tested to 18.2
N
18.2.1
Samples subject to ageing: 6 samples
N
18.2.2
Samples subject to implosion test: 6 samples
N
18.1
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 19 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
18.2.3
Samples subject to mechanical strength test (steel
ball): 6 samples
N
18.3
Non-intrinsically protected tubes tested to 18.3
N
19
Stability and mechanical hazards
--
Mass of the equipment exceeding 7 kg ························ :
N
Apparatus intended to be fastened in place – suitable
instructions
N
19.1
Test on a plane, inclined at 10o to the horizontal
N
19.2
100 N force applied vertically downwards
N
19.3
100 N force, or 13% of weight, applied horizontally to
point of least stability.
N
19.4
Edges or corners not hazardous
19.5
Glass surfaces (exc. laminated) with an area
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1
19.6
Wall or ceiling mountings adequate
20
Resistance to fire
--
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N
b) Exemption for small components as defined in 20.1 Some small components
mounted on UL listed PCB
with flammability of V-1 or
better
P
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
P
20.1.2
Insulation of internal wiring working at voltages > 4 kV No voltage > 4 kV
or leaving an internal fire enclosure, or located within
the areas mentioned in Table 21, not contributing to
the spread of fire
N
20.1.3
Material of printed circuit boards on which the
V-1or better PCB used
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or better
to IEC 60707, unless used in a fire enclosure
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
N
Result - Remark
Edges and corners are
smooth, no hazard existed
Verdict
P
N
Not intended for wall or
ceiling mountings
The plastic front enclosure
complied with sub-clause
20.1.4
See above
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 20 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
20.1.4
Components and parts not covered by 20.1.1, 20.1.2
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the distances
in Table 21 comply with the relevant flammability
category in Table 21
P
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N
Apparatus with voltages >4kV under normal operating
conditions and distances to the enclosure exceed
those specified Table 21, flammability classification
HB40 or better is required for the enclosure
N
20.2
Fire enclosure
--
20.2.1
Potential ignition sources with open circuit
voltage > 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
20.2.2
Internal fire enclosures with openings not exceeding
No internal fire enclosure
1 mm in width and with openings for wires completely
filled
N
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an internal
fire enclosure
N
A
appendix A, Additional requirements for apparatus with protection against
splashing water
--
A.5
Marking and instructions
N
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
N
A.10.
Insulation requirements
N
A.10.2
Splash and humidity treatment
N
A.10.2.1
Enclosure provides protection against splashing water
N
A.10.2.2
Humidity treatment carried out for 7 days
N
B
Appendix B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
--
Complies with IEC 62151 clause 1
N
Result - Remark
No voltage > 4 kV
The EUT is not such
apparatus
Not connected to TNV
Verdict
N
Complies with IEC 62151 clause 2
N
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
N
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 21 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Verdict
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this standard
N
Complies with IEC 62151 clause 6
N
Complies with IEC 62151 clause 7
N
Complies with IEC 62151 annex A, B and C
N
L
Annex L: Additional requirements for electronic flash apparatus for
photographic purposes
--
L.5
Marking and instructions
N
L.5.4
Instructions for battery chargers and Supply apparatus
indicating type or model number of flash apparatus with
which it is to be used
N
Instructions for flash apparatus indicating type or model
number of battery chargers or Supply apparatus with
which it is to be used
N
L.7
Heating under normal operating conditions
N
L.7.1.5 &
L.11.2.7
Lithium batteries meet permissible temp rise in Table
3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC 600864
N
L.9
Electric shock hazard under normal operating
conditions
N
L.9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
N
L.10
Insulation requirements
N
L.10.3.2
High frequency plus ignition
N
L.12
Mechanical strength
N
L.12.1.3
Windows for flash tubes are excluded from steel ball
impact test
N
L.14
Components
N
L.14.6.6
Mains switch characteristics appropriate to its function
under normal conditions
N
L.20
Resistance to fire
N
L.20.1 c)
Trigger coil for discharge purpose is not considered to
be a POTENTIAL IGNITION SOURCE
N
The EUT not such
apparatus
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 22 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Verdict
ATTACHMENT TO TEST REPORT IEC 60065
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Audio, video and similar electronic apparatus – Safety requirements
Differences according to.................... : EN 60065:2002+A1:2006+A11:2008+A2:2010+A12:2011
Attachment Form No........................... : EU_GD_IEC60065K_II
Master Attachment...............................: Date (2011-08)
Copyright © 2011 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
IEC 60065, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause
Contents
Requirement  Test
Add the following annexes:
Result - Remark
Verdict
P
Annex ZA (normative) Other international publications quoted in this standard
with the references of the relevant European publications (See the CB Bulletin)
Annex ZB (normative) Special national conditions
Definition
2.2.Z1
(A11:2008)
2.2
(A12:2011)
3.1
Annex ZC (informative) A-deviations
Add after the definition 2.2.12 the following new
definition:
PORTABLE SOUND SYSTEM
small battery powered audio equipment:
 whose prime purpose is to listen to recorded or
broadcasted sound; and
 that uses headphones or earphones that can be
worn in or on or around the ears; and
 that allows the user to walk around
NOTE Examples are mini-disc or CD players, MP3
audio players or similar equipment.
In EN 60065:2002/A11:2008
Delete the definition 2.2.Z1
Add the following indent at the end of the list:
-
N
N
N
Exposure to excessive sound pressures from
headphone or earphones
NOTE A new method of measurement is described in EN
50332-1, Sound system equipment:
Headphones and earphones associated with portable
audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part
1: General method for “one package equipment”, and in
EN 50332-2, Sound system equipment: Headphones and
earphones associated with portable audio equipment Maximum sound pressure level measurement
methodology and limit considerations - Part 2: Guidelines
to associate sets with headphones coming from different
manufacturers.
3.1
(A12:2011)
In EN 60065:2002
Delete the addition of indent regarding sound
pressure excessive.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 23 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
3.Z1
After 3.2 add a new clause 3.Z1:
(A2:2010)
Result - Remark
Verdict
N
To protect against excessive current, short-circuits
and earth faults in MAINS, protective devices shall
be included either as integral parts of the equipment
or as parts of the building installation, subject to the
following, a), b) and c):
a) except as detailed in b) and c), protective devices
necessary to comply with the reqirements of 11 shall
be included as parts of the equipment;
b) for components in series or parallel with the mains
input to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch, short-circuit
and earth fault protection may be provided by
protective devices in the building installation;
c) it is permitted for equipment supplied via an
industrial mains plug or for PERMANENTLY
CONNECTED APPARATUS, to rely on deticated
over curren and short-circuit protection in the
building installation, provided that the means of
protection, e.g. fuses or circuit breakers, is fully
specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so state,
except that for not via an industrial mains plug or for
PERMANENTLY CONNECTED APPARATUS the
building installation shall be regarded.
4.1.1
Replace the text of the note by: NOTE For
ROUNTINE TEST reference is made to EN 50514.
P
5.4.1 za)
Modify indent za) as follows:
N
(A11:2008)
5.4.1
(A12:2011)
za) For a PORTABLE SOUND SYSTEM, a warning
that excessive sound pressure from earphones and
headphones can cause hearing loss.
In EN 60065:2002/A1:2006 and EN
60065:2002/A11:2008
Delete the modification in indent za)
Add the following clause and annex to the existing
standard and amendments.
Zx Protection against excessive sound pressure
from personal music players
Zx.1 General
This sub-clause specifies requirements for protection
against excessive sound pressure from personal
music players that are closely coupled to the ear. It
also specifies requirements for earphones and
headphones intended for use with personal music
players.
A personal music player is a portable equipment for
personal use, that:
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
N
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 24 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Verdict
is designed to allow the user to listen to recorded or
broadcast sound or video; and primarily users
headphones or earphones that can be worn in or on
or around the ear; and allows the user to walk
around while in use.
NOTE 1 Examples are hand-held or body-worn portable
CD players, MP3 audio players, mobile phones with MP3
type features, PDA’s or similar equipment.
A personal music player and earphones or
headphones intended to be used with personal
music players shall comply with the requirements of
this sub-clause.
The requirements in this sub-clause are valid for
musci or video mode only.
The requirements do not apply:
while the personal music player is connected to an
external amplifier; or
while the headphone or earphones are not used.
NOTE 2 An external amplifier is an amplifier which is not
part of the personal music player or the listening device,
but which is intended to play the music as a standalone
music player.
The requirements do not apply to:
hearing aid equipment and professional equipment;
NOTE 3 Professional equipment is equipment sold through
special sale s channels. All products sold through normal
electronics stores are considered not to professional
equipment.
analogue personal music players (personal music
players without any kind of digital processing of the
sound signal) that are brought to the market before
the end of 2015.
NOTE 4 This exemption has been allowed because this
technology is falling out of use and it is expected that
within a few years it will no longer exist. This exemption
will not be extended to other technologies.
For equipment which is clearly designed or intended
for use by young children, the limits of EN 71-1
apply.
Zx.2 Equipment requirements
No safety provision is required for equipment that
complies with the following:
equipment provided as a package (personal music
player with its listening device), where the acoustic
output LAeq,T, is ≤ 85 dBA measured while playing the
fixed “programme simulation noise” as described in
EN 50332-1; and a personal music player provided
with an analogue electrical output socket for a
listening device, where the electrical output is ≤ 27
mV measured as described in EN 50332-2, while
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 25 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
playing the fixed “programme simulation noise” as
described in EN 50332-1.
NOTE 1 Wherever the term acoustic output is used in this
clause, the 30 s A-weighted equipment sound pressure
level LAeq,T, is meant.
See also Zx.5 and Annex Zx.
All other equipment shall:
a) protect the user from unintentional acoustic
outputs exceeding those mentioned above; and
b) have a standard acoustic output level not
exceeding those mentioned above, and
automatically return to an output level not exceeding
those mentioned above when the power is switched
off; and
c) provide a means to actively inform the user of the
increased sound pressure when the equipment is
operated with an acoustic output exceeding those
mentioned above. Any means used shall be
acknowledged by the user before activating a mode
of operation which allows for an acoustic output
exceeding those mentioned above. The
acknowledgement does not need to be repeated
more than once every 20 h of cumulative listening
time; and
NOTE 2 Examples of means include visual or audible
signals. Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative
listening time, independent how often and how long the
personal music player has been switched off.
d) have a warning as specified in Zx.3; and
e) not exceed the following:
1) equipment provided as a package (player with Its
listening device), the acoustic output shall be ≤ 100
dBA measured while playing the fixed “programme
simulation noise” described in EN 50332-1; and
2) a personal music player provided with an
analogue electrical output socket for a listening
device, the electrical output shall be ≤ 150 mV
measured as described in EN 50332-2, while playing
the fixed “programme simulation noise” described in
EN 50332-1.
For music where the average sound pressure (long
term LAeq,T) measured over the duration of the song
is lower than the average produced by the
programme simulation noise, the warning does not
need to be given as long as the average sound
pressure of the song is below the basic limit of 85
dBA. In this case T becomes the duration of the
song.
NOTE 4 Classical music typically has an average sound
pressure (long term LAeq,T) which is much lower than the
average programme simulation noise. Therefore, if the
player is capable to analyse the song and compare it with
the programme simulation noise, the warning does not
need to be given as long as the average sound pressure of
the song is below the basic limit of 85 dBA.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
Shenzhen Anbotek Compliance Laboratory Limited
Page 26 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Verdict
For example, if the player is set with the programme
simulation noise to 85 dBA, but the average music level of
the song is only 65 dBA, there is no need to give a warning
or ask an acknowledgement as long as the average sound
level of the song is not above the basic limit of 85 dBA.
Zx.3 Warning
The warning shall be placed on the equipment, or on
the packaging, or in the instruction manual and shall
consist of the following:
the symbol of Figure 1 with a minimum height of 5
mm; and the following wording, or similar:
“To prevent possible hearing damage, do not listen
at high volume levels for long periods.”
Figure 1 – Warning label (IEC 60417-6044)
Alternatively, the entire warning may be given
through the equipment display during use, when the
user is asked to acknowledge activation of the higher
level.
Zx.4 Requirements for listening devices (headphones and earphones)
Zx.4.1 Wired listening devices with analogue
input
With 94 dBA sound pressure output LAeq,T, the input
voltage of the fixed “programme simulation noise”
described in EN 50332-2 shall be ≥ 75 mV.
This requirement is applicable in any mode where the
headphones can operate (active or passive),
including any available setting (for example built-in
volume level control).
P
N
N
NOTE The values of 94 dBA – 75 mV correspond with
85dBA – 27 mV and 100 dBA – 150 mV.
Zx.4.2 Wired listening devices with digital input
With any playing device playing the fixed “programme
simulation noise” described in EN 50332-1 (and
respecting the digital interface standards, where a
digital interface standard exists that specifies the
equivalent acoustic level), the acoustic output LAeq,T of
the listening device shall be ≤ 100 dBA.
This requirement is applicable in any mode where the
headphones can operate, including any available
setting (for example built-in volume level control,
additional sound feature like equalization, etc.).
N
NOTE An example of a wired listening device with digital
input is a USB headphone.
Zx.4.3 Wireless listening devices
In wireless mode:
with any playing and transmitting device playing
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 27 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Verdict
the fixed programme simulation noise described in
EN 50332-1; and
respecting the wireless transmission standards,
where an air interface standard exists that specifies
the equivalent acoustic level; and with volume and
sound settings in the listening device (for example
built-in volume level control, additional sound feature
like equalization, etc.) set to the combination of
positions that maximize the measured acoustic output
for the abovementioned programme simulation noise,
the acoustic output LAeq,T of the listening device
shall be ≤ 100 dBA. NOTE An example of a wireless
listening device is a Bluetooth headphone.
Zx.5 Measurement methods
Measurements shall be made in accordance with EN
50332-1 or EN 50332-2 as applicable. Unless stated
otherwise, the time interval T shall be 30 s.
N
NOTE Test method for wireless equipment provided
without listening device should be defined.
6.1
(A11:2008)
Replace the entire subclause in EN 60065:2002 and
EN 60065:2002/A1:2006 by:
Ionizing radiation
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided under
normal operating conditions and under fault
conditions.
Compliance is checked by measurement under the
following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those internal
adjustments or pre-sets which are not locked in a
reliable manner, are adjusted so as to give maximum
radiation whilst maintaining an intelligible picture for 1
h, at the end of which the measurement is made.
NOTE 1 Soldered joints and paint lockings are
examples of adequate locking.
The dose-rate is determined by means of a radiation
monitor with an effective area of 10 cm2, at any point
10 cm from the outer surface of the apparatus.
Moreover, the measurement shall be made under
fault conditions causing an increase of the highvoltage, provided an intelligible picture is maintained
for 1 h, at the end of which the measurement is
made.
The dose-rate shall not exceed 1μSv/h (0,1 mR/h)
taking account of the background level.
NOTE 2 These values appear in Directive
96/29/Euratiom of 13th May 1996.
A picture is considered to be intelligible if the
following conditions are met:
- a scanning amplitude of at least 70% of the usable
screen width;
- a minimum luminance of 50 cd/m2 with locked blank
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 28 of 44 Report No. R011508965S
IEC 60065
Clause
Z1
(A11:2008)
General
General
(A2:2010)
Requirement  Test
Result - Remark
raster provided by a test generator;
- a horizontal resolution corresponding to at least 1,5
MHz in the centre, with a similar vertical degradation;
- not more than one flashover per 5 min.
Add the following new clause after Clause 20:
Z1 Resistance to candle flame ignition
A television set shall be so designed that the
likelihood of ignition and the spread of fire caused by
a candle flame is reduced.
NOTE 1 An apparatus with a viewing screen is not
regarded to be a television set if it is declared not to
be so by the manufacturer.
This requirement does not apply to the display screen
of rear projection TV’s.
NOTE 2 This exemption has been allowed because
this technology is falling out of use and it is expected
that within a few years it will no longer exist. This
exemption will not be extended to other technologies.
NOTE 3 The frame around the screen is not
exempted from the requirements.
Wood and WOOD-BASED MATERIAL with a
thickness of at least 6 mm is considered to fulfil the
V-1 requirement when applying CLC/TS 62441.
Compliance is checked according to CLC/TS 62441.
NOTE 4 The term vertical, as used in the first dash of
clause 5.2 of CLC/TS 62441, does not mean a mean
a perfectly vertical position. It should be interpreted
as any surface that can be touched by the flame of a
candle of 150 mm height and 20 mm diameter while
the candle is still touching the supporting surface. A
typical candle used in the home is assumed to be 20
mm diameter.
NOTE 5 It is expected that CLC/TS 62441 will in the
future be replaced by a standard, at which time that
standard will become applicable, subject to a vote by
National Committees at the time.
13.3.1
Delete note 4.
14
Delete note 4 and note 5.
15.1.1
Delete notes 1 and 2.
15.2
Delete note 2.
16.1
Delete note 1.
16.2
Delete the note.
20
Delete note 2.
Annex B
Replace note 1 by: In the CENELEC countries listed in IEC
62151, special national conditions apply.
Annex G
Delete the note.
Annex J.2
Delete the notes of Table J.1.
Annex N
Add after the introduction: For ROUTINE TEST reference is
made to EN 50333. (Replaced by EN 50514)
In IEC 60065:2001/A2
Delete all the “country” notes according to the following list:
5.3
Note
5.4.1
Note
20
Note
For special national conditions, see Annex ZB.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
N
P
P
Shenzhen Anbotek Compliance Laboratory Limited
Page 29 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Verdict
Bibliography Additional EN standards.
P
ZA
Normative references to international publications with their corresponding
European publications
P
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
P
2.6.1
DK: The following is added:
N
Certain types of Class I apparatus, see 15.1.1, may
be provided with a plug not establishing earthing
continuity when inserted in Danish socket-outlets
Justification: Heavy Current Regulations, Section 107.
3 Z1
Denmark
(A2:2010)
Add to the end of the subclause
N
Due to many existing installations where the socketoutlets can be protected with fuses with higher rating
than the rating of the socket-outlets the protection for
pluggable equipment type A shall be an integral part
of the equipment.
Justification: In Denmark an existing 13 A socket
outlet can be protected by a 20 A fuse.
5.3
Finland, Norway and Sweden
(A2:2010)
To the end of the subclause the following is added:
N
CLASS I apparatus which is intended for connection
to the building installation wiring via a plug or an
appliance coupler, or both and in addition is intended
for connection to other apparatus or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the
network TERMINALS and ACCESSIBLE parts, have
a marking stating that the apparatus must be
connected to an earthed MAINS socket-outlet.
The marking test in the applicable countries shall be
as follows:
In Finland: “Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan”
In Norway: “Apparatet mä tilkoples jordet stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat uttag”
5.4
Finland, Norway and Sweden
(A11:2008)
To the end of 5.4 the following is added:
CLASS I apparatus which is intended for connection
to the building installation wiring via a plug of
appliance coupler, or both and in addition is intended
for connection to other apparatus or a network shall, if
safety relies on connection to protective earth or if
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 30 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Verdict
surge suppressors are connected between the
network TERMINALS and ACCESSIBLE parts, have
a marking stating that the apparatus must be
connected to an MAINS socket-outlet with protective
earth.
The marking text in the applicable countries shall be
as follows:
In Finland: “Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan”
In Norway: “Apparatet mä tilkoples jordet stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat uttag”
5.4.1
Norway and Sweden
(A11:2008)
The end of 5.4.1 (after the compliance statement) the
following is added:
The screen of the cable distribution system is normally
not earthed at the entrance of the building and there is
normally no equipotential bonding system within the
building. Therefore the protective earthing of the
building installation need to be isolated from the
screen of a cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what country
the equipment is intended to be used in:
“Equipment connected to the protective earthing of the
building installation through the mains connection or
through other equipment with a connection to
protective earthing – and to a cable distribution
system using coaxial cable, may in some
circumstances create a fire hazard. Connection to a
cable distribution system has therefore to be provided
through a device providing electrical isolation below a
certain frequency range (galvanic isolator, see EN
60728-11)”
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator
shall provide electrical insulation below 5 MHz. The
insulation shall withstand a dielectric strength of 1,5 kV
r.m.s., 50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr – og er
tilkoplet et kabel-TV nett, kan forårsake brannfare.
For å unngå dette skal det ved tilkopling av utstyret
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 31 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Verdict
til kabel-TV nettet installeres en galvanisk isolator
mellom utstyret og kabel- TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och
samtidigt är kopplad till kabel-TV nät kan i vissa fall
medfőra risk főr brand. Főr att undvika detta skall vid
anslutning av utrustningen till kabel-TV nät galvanisk
isolator finnas mellan utrustningen och kabel-TV
nätet.”
13.3.1
NO: To the second paragraph the following is added:
N
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered to
be equal to the line-to-line voltage, and will remain
230V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
15.1.1
Denmark
(A11:2008)
The text of the Danish SNC in EN 60065:2002 has
been modified as follows:
To the first paragraph the following is added:
In Denmark, supply cords of single-phase appliances
having a rated current not exceeding 13 A shall be
provided with a plug according to the Heavy Current
Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used in
locations where protection against indirect contact is
required according to the wiring rules shall be
provided with a plug in accordance with the Heavy
Current Regulations, Section 107-2-D1 standard
sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to CLASS
II apparatus with a rated current of 2,5 A shall be in
accordance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-4a.
Other current ratings socket outlets shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA 42b.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA 15a or DK 1-7a.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 32 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Verdict
Justification: Heavy Current Regulation, Section 1072-D1
15.1.1
IE: Apparatus which is fitted with a flexible cable or
cord shall be provided with a 13 A plug in accordance
with Statutory Instrument 525:97, “13 A Plugs and
Conversion Adapters for Domestic Use
Regulations:1997”.
N
Justification: SI 525:1997
15.1.1
NO: Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications given in
CEE Publ. 7 as far as a applicable, with the following
amendments:
N
§ 8 Dimensions
a 2,5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosure Standard
Sheet I.
§ 24 Mechanical strength
A 2,5 A 250 V socket-outlets for CLASS II electronic
apparatus are tested as specified in 12.1.3 of EN
60065. Also the protecting rim shall be tested.
Justification: Act of 24 May 1929 relating to
supervision of electrical installation (TEA 1929/FEL
1998).
15.1.1
UK: Apparatus which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with a
“standard plug” in accordance with Statutory
Instrument 1768:1994, unless exempted by those
Regulations.
N
NOTE “Standard plug” is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS
1363 or an approved conversion plug.
Justification: SI 1768:1994
J.2
NO: After J.1 the following is added:
In Norway, due to IT power distribution system used,
the a.c. MAINS supply voltage is considered to be
equal to the line-to-line voltage, and will remain 230V
in case of a single earth fault.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 33 of 44 Report No. R011508965S
IEC 60065
Clause
Requirement  Test
Result - Remark
Verdict
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN)
P
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
N
IT: user instructions in Italian language including a
conformity declaration
N
IT: certification number on the back cover
N
DE: The following requirement applies:
N
6.1
For the operation of any cathode ray tube intended for
the display of visual images operating at an
acceleration voltage exceeding 40 kV, authorization is
required, or application of type approval
(Bauartzulassung) and marking.
Justification: German ministerial decree against
ionizing radiation (Röntgenverordnung), in force since
2002-07-01, implementing the European Directive
96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt,
Bundeshallee 100, D-38116 Braunschweig, Tel.:
Int+49-531-592-6320, Internet :http://www.ptb.de
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
Justification: Ordinance (1990:944) on Prohibition in
Connection with handing. Importation and exportation
of Chemical Products (Certain Cases)
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 34 of 44 Report No. R011508965S
Test Tables
7.1
TABLE: Temperature rise measurement
P
Power consumption in the OFF/Stand-by·········· : --
--
Position of the functional switch (W)··················· : --
--
Operating conditons
Un (V)
Hz
In (A)
Pn (W)
Uout (V)
Pout (W)
Operating Condition/Status
99
50
0.630
37.6
--
--
110
50
0.519
37.5
--
--
1/8 of Max output power on
speakers
240
50
0.334
37.2
--
--
264
50
0.313
37.1
--
--
99
60
0.751
37.7
--
--
110
60
0.652
37.5
--
--
240
60
0.392
37.1
--
--
264
60
0.373
37.1
--
--
Supply voltage (V) ..............................:
99V 60Hz
264V60Hz
--
Ambient Tmin (C) ................................ :
35.0
35.0
--
Ambient Tmax (C) ................................:
35.0
35.0
--
Maximum measured temperature T of part/at:
(Normal operation)
Allowed Tmax (C)
PCB near IC
24.5
24.7
95=130-35
DC terminal
15.4
15.2
Ref.
Enclosure outside
9.3
9.4
45=80-35
Enclosure inside
11.4
11.6
60=95-35
E-cap(C88)
28.6
29.1
70=105-35
Ambient
35℃
35℃
---
Comments:
1. The temperatures were measured by thermal couple under worst case normal mode defined in 4.2.1 and at
voltage as described above.
Winding temperature rise measurements
--
Ambient temperature t1 (℃) ································:
--
--
Ambient temperature t2 (℃)································· :
--
--
Temperature rise dT of winding:
dT = (R2 – R1) x (234.5 + t1) – (t2 – t1)
R1
R1 (Ω)
R2 (Ω)
dT (K)
Limit max. (K)
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Insulation
class
Shenzhen Anbotek Compliance Laboratory Limited
Page 35 of 44 Report No. R011508965S
Test Tables
--
--
--
--
--
--
Note: According to the user manual, the appliance is intended to be used in moderate climate, so the basic
ambient temperature is 35℃.
7.2
TABLE: Softening temperature of thermoplastics
T – normal conditions
(°C)
Temperature T of part
--
N
--
T – fault conditions
(°C)
--
Min. T
softening (°C)
--
Note:
10.3
TABLE: Insulation resistance measurements
N
Insulation resistance R between
R (MΩ)
Required R (MΩ)
---Note:
1) BI: Basic insulation; SI: Supplementary insulation; DI: Double insulation; RI: Reinforced insulation
2) Evaluated with external adapter, the test performed between L/N and the terminal/enclosure of sample.
10.3
TABLE: Electric strength measurements
Test voltage applied between
Input to enclosure
P
Test voltage (V)
Breakdown
DC 500V
No
Note:
1) BI: Basic insulation; SI: Supplementary insulation; DI: Double insulation; RI: Reinforced insulation
2) Evaluated with external adapter, the test performed between L/N and the terminal/enclosure of sample.
11.2
No.
1
TABLE :Summary if fault condition Tests
P
Voltage (V) 0,9 or 1,1 times rated Voltage·····················: 24Vd.c.
--
Frequency (Hz)··································································· : --
--
Ambient temperature (℃)················································· : 25℃
-Fuse current
Component no.
Fault
Test time
Result
(A)
After SC, unit shut down immediately
E-cap(C88)
s-c
30 mins
-and recoverable when fault removed.
No damage, no hazards.
Note:
1) Supplementary information : o-c: open circuit, s-c: short circuit, o-l: overload, b-l: blocked, l-k: locked
13.3/13.4
TABLE: Clearances and creepage distances
Operating Voltage V
Urms V
Location
Upeak V
N
Clearance mm
Minimum
Actual
Creepage mm
Minimum
Basic/Supplementary:
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Actual
Shenzhen Anbotek Compliance Laboratory Limited
Page 36 of 44 Report No. R011508965S
Test Tables
--
--
--
--
--
--
--
--
--
--
--
--
--
Reinforced/Double:
-Test conditions: - Pollution degree:
- Material group:
II
IIIb
- Main transient voltage: 2,50KV
Note: (RI)  Reinforced insulation, (SI)  Supplementary insulation, (BI)  Basic insulation
14
Object/part
No.
PCB
TABLE: List of critical components
Manufacturer/
trademark
Huan qiang
electronice co,LTD
P
Type/model
Technical data
FR-4 ,94-V0
V-0, 130℃, Min
thickness
Standard
(Edition / year)
UL 94
Mark(s) of
conformity1)
UL E251754
0.8mm
Adapter
PINLEI
HC-60SV24
Input: 100240V~ 50/60Hz
1.2 MAX
IEC EN
60950-1
output: 24V
2.5A
1) An asterisk indicates a mark which assures the agreed level of surveillance.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
TUV
Shenzhen Anbotek Compliance Laboratory Limited
Page 37 of 44 Report No. R011508965S
Photos
Photo 1
[ √ ] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[
] internal
Photo 2
[ √ ] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[
] internal
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 38 of 44 Report No. R011508965S
Photos
Photo 3
[
] front
[ √ ] rear
[
] right side
[
] left side
[
] top
[
] bottom
[
] internal
Photo 4
[
] front
[
] rear
[
] right side
[
] left side
[ √ ] top
[
] bottom
[
] internal
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 39 of 44 Report No. R011508965S
Photos
Photo 5
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[ √ ] bottom
[
] internal
Photo 6
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[ √ ] internal
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 40 of 44 Report No. R011508965S
Photos
Photo 7
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[ √ ] internal
Photo 8
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[ √ ] internal
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 41 of 44 Report No. R011508965S
Photos
Photo 9
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[ √ ] internal
Photo 10
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[ √ ] internal
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 42 of 44 Report No. R011508965S
Photos
Photo 11
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[ √ ] internal
Photo 12
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[ √ ] internal
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 43 of 44 Report No. R011508965S
Photos
Photo 13
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[ √ ] internal
Photo 14
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[ √ ] internal
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 44 of 44 Report No. R011508965S
Photos
Photo 15
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[ √ ] internal
Photo 16
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[ √ ] internal
***End of the report***