Broseley Winchester gas stove Installation and Operation Manual

Broseley Winchester gas stove Installation and Operation Manual

The Broseley Winchester is a radiant convector fuel-effect gas stove that can be installed in any adequate area suitable for solid fuel fires and stoves. The stove can use a class 1, class 2 and pre-cast flue. The stove is rated at less than 7kw and therefore does not normally require additional ventilation in the room.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Broseley Winchester Gas Stove Installation Manual | Manualzz

Installation and Operation Manual

Winchester

Gas Stove

Revision: GB09b

© 2007-2008 Broseley Fires Ltd

The Winchester Gas Stove

Installation, Servicing and User Instructions.

Technical Information

Natural Propane

G20/12H G31/13P

Heat Input (Gross)

Supply Pressure

6.9 Kw/Hr

20 Mbar

6.9Kw/Hr

37 Mbar

Injector 18/460

Contents

Arranging the layout of the coals/logs

Dimensions and Details

Extinguishing the stove fully

7-10

2

11

Igniting the permanent pilot light

Note to the installation engineer

11

12

Sitting the appliance

Test for Spillage

4

12

Broseley Fires Ltd

Knights Way

Battlefield Enterprise Park

Shrewsbury

SY1 3AB

United Kingdom

Telephone +44(0) 1743 461444

Fax +44(0) 1743 461446

© 2007-2008 Broseley Fires Ltd

Winchester Gas Dimensions

Height

Height to centre of rear flue spigot

595mm

455mm

Depth

Width

Centre of top flue to rear of stove

465mm

590mm

150mm

Weight 116kg

Maximum heat output (approx.) 5.6 Kilowatts

© 2007-2008 Broseley Fires Ltd

THANK YOU FOR PURCHASING A GAS FIRED STOVE

Broseley Fires Ltd, a family run company, was founded as an appliance and design development company in 1975.

Since then we have built up an enviable reputation for the quality, reliability and fuel efficiency of our stoves.

These instructions have been carefully prepared to guide the installer and end-user through the relevant methods and standards for installation of your new Gas Stove.

Correctly installed and operated, your stove will give you many years of warmth and reliability. Therefore, we would suggest that you read the whole instruction manual prior to handing it to your installer. That way you will have a clearer picture of what is involved.

IMPORTANT INFORMATION

APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH NATIONAL

REGULATIONS

1. The stove is designed to run on either natural gas or LPG. The burner units are not interchangeable between the two types of gas. This stove is a radiant convector fuel-effect appliance. The site of the stove i.e. the chimney, flue and hearth etc., must comply with the current building regulations and codes of practice before the stove is installed (see sitting the appliance).

2. It is required by law that the complete assembly, installation and commissioning of gas-fired stoves is carried out by a professionally qualified and accredited gas fitter who is registered on the “gas safe” register DO NOT ATTEMPT TO

INSTALL THIS APPLIANCE YOURSELF. Broseley Fires Ltd takes no responsibility for any breach of the legal standards prevailing as far as the fitting of this appliance is concerned.

3. The stove is an efficient appliance, giving off convected conducted and radiated heat. All surfaces of the stove except the control knob are considered to be working surfaces. Adequate precautions should always be taken to protect children, the elderly, the infirm and pets etc. from coming into contact with the stove.

4. Ensure that the local gas distribution conditions, the nature of the gas pressure are compatible with the data plate fitted between the right hand legs and on the control valve.

These instructions have been compiled in accordance with BS5258 part 12:1986. The

Gas Safety Installation and Use Regulations 1994. The Building Regulations (issued by the Department of the Environment) The Building Standards (Scotland) (Consolidation)

Regulations.

© 2007-2008 Broseley Fires Ltd

SITTING THE APPLIANCE

The gas supply connection to the appliance is at the rear right hand side. The connection requires an 8mm-diameter semi-rigid pipe, not more than 1 metre in length.

The appliance can be installed in any adequate area suitable for solid fuel fires and stoves. It can use a class 1, class 2 and pre-cast flue.

To ensure maximum and efficient use of the stove, we recommend the following hearth specifications.

The hearth must be at least 300mm at any angle in front of the incandescent heat source

(the burner surface) and the burner surface requires a clearance of 150mm each side. The effect of this will mean the hearth must extend about 200mm in front of the legs of the stove. The hearth must be made of non-combustible material at least 12 millimeters thick.

On all installations, no combustible material such as carpet should cover the hearth. To prevent this from happening, the hearth should be at least 50mm above the level of the floor. If this is not possible, a fender/kerb of a similar height should be placed around the edge of the hearth.

If the appliance has to be located in an opening, there must be a clearance of a minimum of 100mm each side of the stove. The rear of the appliance should have a minimum

75mm air gap between the stove and the back wall. There must be a minimum clearance of 610mm from any combustible surface. i.e. skirting board or beams.

Stove Assembly

Please check that the following components are included before you start on the assembly:

Stove Box

1 x cast iron stove body

1 x flue spigot

1 x flue spigot blanking disc (for blanking unused flue outlet)

Burner Box

1 x burner unit

1 x instruction booklet

2 x burner fixing brackets and screws

2 x burner retaining bolts with nuts

1 x remote control unit with plug-in sensor unit

Ceramic Box

Coal Option – See page 9

Log Option – See page 10/11.

© 2007-2008 Broseley Fires Ltd

Before installing the stove ensure the gas to be used i.e. natural (mains) gas or LPG corresponds with the identification plate on the burner.

Unscrew the door handle and open the main stove door.

With the burner out of the stove, screw the two burner fixing brackets to the rear of the burner so that the “U” slot faces upwards and locates with the screw holes in the internal rear plate.

Next, with the stove stood upright insert the burner (control first) through the door. Dip the controls through the bottom of the stove so that the burner comes to rest onto the brackets located at the front. Fix using nuts and bolts provided.

The “U” sections on the burner fixing brackets will then line up with the two holes located on the internal rear plate. Finally screw the two screws and washers provided through the “U” sections to hold the burner securely in place against the rear plate.

Flue Connection

The stove must be installed in accordance with current gas and buildings regulations

BS5871: Part1.

Before you install the stove, make sure the chimney flue outlet is correctly positioned to align with the flue outlet on the stove and that the chimney is in good condition. If not, a chimney liner must be installed or a suitable class II gas flue used. A draught is necessary to ensure the products of combustion are fully evacuated. Due to the internal dilution/diversion system in the stove, it is not obligatory to line the chimney but local conditions will apply. The flue will have to be inspected by a CORGI registered installer and passed as suitable/sound.

The Gas Stove is suitable for both Class I & II and pre-cast flues (The Building

Regulations 2000). The stove can be installed as a top or rear outlet without any additional parts.

Ideally it is recommended that a minimum height of 610mm from the stove should be established before any significant changes of the direction of the flue. Horizontal or negative gradients should be avoided. The flue must have a minimum height of 3 metres to insure adequate draught.

Prior to installation, the installer should insure that the flue is free from obstruction and any dampers must be fixed in a permanently open position. Ensure the chimney is not closed and that it has been swept and subsequently smoke tested.

Make sure that rain, birds or any foreign body cannot get into the chimney to cause damage or blockage. This problem can normally be overcome by fitting an approved gas cowl. It is essential for the effective running of your stove that the chimney draws properly to allow the products of combustion to escape.

© 2007-2008 Broseley Fires Ltd

VENTILATION (GB ONLY)

The gas stove is rated at less than 7kw and therefore does not normally require additional ventilation in the room (BS5871 – part II).

GAS CONNECTION

A minimum 15mm-diameter gas supply pipe must be used to within 1 metre of the installation with the final connection to the stove to be completed with the suitable 8mm semi-rigid gas pipe. The 8mm pipe should be connected to the inlet of the gas valve using the nut and 8mm olive provided. Support the control whilst finally tightening the supply pipe. A gas safety tap/restrictor elbow with a pressure test point at the inlet to the burner is provided.

PRESSURE TESTING

Always make sure that there is adequate gas pressure and volume to the stove. The relevant pressures are on the ID plate on the gas control knob.

1. For natural gas, this is 20mbar measured at the burner test nipple situated at the inlet connection to the stove with the appliance in the full rate position.

2. For propane, this is 37mbar measured at the burner test nipple situated at the inlet connection to the stove with the appliance in the full rate position.

3. Ensure that the gas pressure to the stove is maintained when it is operating at the same time as other appliances in the building and that a suitable pressure gauge is used i.e. a manometer. Any service call as a result of incorrect gas pressure

will be chargeable.

ARRANGING THE LAYOUT OF THE CERAMICS

Only the ceramics supplied with this appliance should be used. The ceramics should only be laid as described. Replacement ceramics are available from your dealer.

Whilst arranging the ceramics, ensure that the pilot is not obstructed.

Broseley Fires Ltd accepts no responsibility for any injury sustained whilst handling hot ceramics.

Before any ceramics are placed in position ensure that the burner is operating

correctly. The flames should be fairly even across the burners mesh top.

Ceramics which are found to be placed other than in accordance with these instructions will result in a charge being made following any service callout.

© 2007-2008 Broseley Fires Ltd

COAL LAYOUT

Warning: Ceramic coals are very fragile so always handle with care when fitting them. Follow these instructions carefully. Ceramics that are positioned wrongly could seriously alter the performance of your appliance.

Step 1

Open the door fully, you may wish to lift it from its hinges. Take the large base ceramic coal matrix making sure the front edge is facing towards you. Pick up the ceramic with both hands, placing the fingers gently through the flame holes. Support the weight at all times as the ceramics are fragile and damage easily. During the

placement do not force the ceramic into position as it will break. Turn the front edge of the ceramic to face downwards and insert the right hand side first into the rear right corner of the stove. It should now be possible to gently follow with the left hand and at the same time rotate the ceramic upwards so that it lays flat on the burner. The ceramic should be against the back of the stove and central about the burner mesh.

Step 2

Take the larger of the rear ceramic (left hand side) and locate it into position on the base ceramic via the location holes and lugs. Ensure the flat rear side of the ceramics is against the back of the stove.

Step 3

Take the smaller of the rear ceramics (right hand side) and locate it into position on the base ceramic via the location holes and lugs. Ensure the flat rear side of the ceramic is against the back of the stove.

The two rear pieces fit together.

Step 4

Place the 6 loose coals across the centre of the fire, so that they bridge the gap between the rear and base ceramics. These coals should be rested gently in position.

Do not push them into the gap, as this will prevent the flames from burning evenly and effectively. The path of the flame should not be obstructed.

IMPORTANT

Please follow these instructions carefully. Ceramics that are positioned wrongly could seriously alter the performance of your appliance.

© 2007-2008 Broseley Fires Ltd

Winchester Coal Fitting Instructions

© 2007-2008 Broseley Fires Ltd

Log Ceramic Fitting Instructions

THE CERAMIC LOGS AVE LOCATION POINTS ON THEM THAT WILL

HELP YOU LOCATE THEM IN THE CORRECT POSITION.

PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY AND USE

THE DIAGRAMS TO ASSIST YOU.

Stage 1

Position the largest ceramic on top of the burner and push it firmly against the rear of the stove. Insure that it is central about the burner.

Stage 2

Position the rear log onto the two location lugs towards the rear of the base ceramic as shown in the diagram.

Stage 3

Position the next log as shown in the diagram (below). This log also has two location points.

Stage 4

This log is located on a lug that has been formed on top of the previous log. Locate this lug first, the other end of the log is a notched out section in the base ceramic.

Stage 5

This log is located on a lug that has been formed on top of the rear log. Please make sure that this log and all others are in position, exactly as shown in the diagrams.

© 2007-2008 Broseley Fires Ltd

OPERATING THE STOVE

It is important to read these instructions thoroughly before lighting the stove.

The gas stove operates with a traditional permanent pilot light.

The knobs for ignition and power control are located on the lower right hand side of the stove.

The pilot light is located at the front middle of the coal matrix.

If the Flame Supervision Device Actuating Flame (the pilot light) is extinguished by intention or not, no attempt should be made to re-light until 3 minutes have elapsed.

IGNITING THE PERMANENT PILOT LIGHT

1. Depress the rear control knob fully.

2. Whilst depressed, turn knob sharply 90 degrees anti-clockwise to “pilot” setting.

Repeat until pilot light is visibly lit. You should fell some resistance and hear a click. Repeat until the pilot lights.

3. Keep knob depressed at this point for 15-20 seconds.

4. Upon releasing, turn the knob anti-clockwise until it stops in the permanent pilot light position. The permanent pilot light will remain lit. This is the position for remote operation and can be left with the pilot running. You may wish to turn off the stove during long periods of non-use perhaps during the summer months.

SEE SEPARATE INSTRUCTIONS FOR RUNNING THE STOVE UNDER REMOTE

CONTROL.

In the event of a failure of the remote control, the front control valve can be adjusted manually by rotating between the high and low positions.

EXTINGUISHING THE STOVE FULLY

1. From any heat setting or the permanent pilot, depress the rear control knob and turn clockwise to “OFF” position.

Should the glass door become broken or damaged in any way, turn your stove off and do not attempt to re-light it. Contact your dealer for a replacement to be fitted before relighting the appliance.

PLEASE EXPLAIN TO THE CUSTOMER THESE LIGHTING AND

EXTINGUSIHING PROCEDURES AND THAT IT IS NORMAL FOR THE

STOVE TO GIVE OFF ODOURS WHILST THE PAINT, SEALANT AND CAST

IRON MATURES.

© 2007-2008 Broseley Fires Ltd

THE REMOTE CONTROL

POSITIONING THE RECEIVER

After fitting the batteries in the receiver and the hand set, place the receiver anywhere on the hearth. There is a long lead on the receiver to allow you to position the receiver towards the front of the hearth, if you wish to see the light come on when the handset is in use. Place the lead on the hearth also. Failure to do this will cause malfunction of the unit.

OPERATING INSTRUCTIONS FOR G30-ZRPTT REMATE CONTROL

Caution! Read these instructions entirely before use.

G30-ZRPTT remote controls must be installed and operated according to all locally applicable regulations!

G30-ZRPTT Remote Controls are designed for use only in gas fires equipped with specially designed combination controls (GV34 or GV36 retrofitted with a motor) produced by Mertik Maxitrol. Due to the integrated thermostat, the G30-

ZRPTT is not to be used with open gas fires!

Technical Data

Ambient Temperature

Batteries

Frequency: ON 40,5kHz,

Transmitter & Receiver

OFF 40kHz max. 60°C 140°F

Connecting Cables: max. 180°C 356°F

Handset: 1 x 9V block (alkaline recommended)

Receiver: 4 x 1,5V AA (alkaline recommended)

Connections

The G30-ZRPTT is intended for use only with motorized gas combination controls models GV34 (or GV36 retrofitted with a motor). The receiver cable must be firmly plugged onto the flat blade connectors (motor: 6,3 and 4,8mm; micro switch: both 2,8mm, see llustration 2).

A

© 2007-2008 Broseley Fires Ltd

B

Transmitter Function

Set the Display

• After connecting the battery or by simultaneously pressing AUTO and TIMER, the display flashes. You are in set mode.

• From set mode, press AUTO to switch from °F (and 12 hour clock) to °C (and

24 hour clock) or vice versa.

• The display will automatically return to manual mode after some time, but you may immediately return to manual by depressing the TIMER button.

Set the current Time

• After connecting the battery or by simultaneously pressing AUTO and TIMER, the display flashes. You are in set mode.

• From set mode, press (p) to set the hour and (q) to set the minute.

• Wait or press TIMER to return to “manual“ mode.

Programming the Desired Set Temperature

• Press AUTO until the display flashes.

• Press (p) or (q) to set the desired temperature.

• Wait or press AUTO to switch to automatic mode.

• A sensor in the transmitter measures the room temperature. The controller compares the room temperature with the set temperature and sends a signal to the receiver to turn the gas valve motor, which adjusts the flame height accordingly.

Programming the Timer

• Press TIMER until P1* flashes (period 1, heating cycle on).

• Set the time for the beginning of the first heating period by pressing (p) for hour and (q) for minute.

• Press TIMER again; P1w appears.

Illustration 2: Cover with Connectors for Micro Switch

TIMER

AUTO

(Programming the Timer)

• Set the time for the end of the first heating period.

• Press TIMER again to set the second heating period P2* (heat on) and P2w

(heat off).

• Store both heating periods by pressing TIMER again.

• If only one heating period is desired, program the same time for P2* and P2w.

Manual Mode (MAN in display) for Manual Flame Height Adjustment

• Press (p) to turn on the fire (main burner) or to increase flame height

• Press (q) to decrease flame or to turn down to pilot.

• To incrementally increase or decrease the flame height lightly tap either the (p) or (q) button.

• The “send“ symbol appears in the upper left corner of the display when either button is depressed.

• The LED of the receiver flashes when knob B of the valve reaches its end stops.

Automatic Mode (AUTO in display) for Temperature Control

© 2007-2008 Broseley Fires Ltd

• Briefly press AUTO. The set temperature will appear briefly before the display reverts to the room temperature.

Timer Mode (TIMER in display)

• During heating periods P1* and P2*, the temperature is controlled in the same manner as in automatic mode.

• When the timer program turns to w (heating cycle off), the motor will turn the valve to pilot and there is no temperature control. This minimizes battery consumption.

• You may press AUTO to verify the set-temperature and then press TIMER to return to timer mode.

• You may press either the (p) or (q) button from any mode for manual override.

• To prolong battery life, we recommend switching the transmitter to manual mode and turning the fire to pilot with the (q) button before turning the appliance off. If the transmitter is left in automatic or timer mode, the batteries will continue to be used when the appliance is off.

Changing the Battery

• If BATT appears in upper right hand corner of the display or if the LED of the receiver becomes faint, please change the battery from transmitter or receiver. If the batteries lose power, the flame height can be adjusted by manually turning knob

B (see illustration 2).

Note

Please note, the placement of the transmitter (temperature sensor) is important to assure proper temperature regulation. Generally, a more contstant temperature will be assured, if the transmitter is not too far from the gas appliance. Before switching to AUTO or TIMER mode, press either button

(p) or (q) to verify the reception (when the send symbol appears in the transmitter display, the receiver’s LED must illuminate). For the AUTO or

TIMER mode to function correctly, the transmitter must remain within range of the receiver. The transmitter should not be used in very close proximity to the receiver (less than 1m / 3ft) as this could, in very rare cases, produce a electronic switching error. This error could block the motor when the knob reaches the end points of its turning radius. The knob must then be turned manually to free the blockage.

The temperature is controlled by activating the motor for a specific length of time to adjust the appropriate flame height. This time is calculated by the transmitter and depends on variables such as room size, heater capacity, battery power, etc.

Therefore, a few cycles are necessary before an optimum is achieved. If a low flame is sufficient to provide enough warmth to the room, then the appliance will cycle between low fire and off. This allows longer periods with the flame on and provides a more uniform room temperature.

NOTE TO THE INSTALLATION ENGINEER

Please make sure the customer is familiar with the initial lighting and operating procedures before leaving the site and that this instruction booklet is left with them when the final commissioning is complete.

© 2007-2008 Broseley Fires Ltd

TEST FOR SPILLAGE

A Spillage Test MUST be made before the installed fire is left with the customer.

Carry out the test by first closing all doors and windows in the room containing the fire.

Insure that the fire is burning at full rate for a minimum of 10-15 minutes.

Using a lighted smoke match, run along under the rear edge of the stove. The draught diverter box is situated centrally, the entry being in the rear panel for the stove. Observe the smoke being drawn into the dilution box. After 10 minutes repeat the test.

If there is an extractor fan in a nearby room the spillage test must be repeated with the fan running and all connecting doors between the fire and fan left open.

If there are still problems, the chimney / flue may require attention. Disconnect the stove and seek expect advice.

SPILLAGE MONITORING SYSTEM

This appliance is fitted with an atmospheric sensing spillage monitoring system, in the form of an oxygen depletion-sensing pilot. This is designed to shut down the fire within a safe period if there is an excessive build up of products of combustion within the room space. This would usually only occur if the flue path suffered severe blockage and / or ventilation was severely impeded.

THE FOLLOWING ARE IMPORTANT WARNINGS RELATIVE TO THE

SPILLAGE MONITORING SYSTEM

1. The installer must not attempt any adjustments to the spillage monitoring system.

2. There must be no attempt to disable the spillage monitoring system.

3. It is not possible to replace individual parts of the pilot assembly on the appliance

– only a complete pilot assembly (including thermocouple) may be fitted in the event of a replacement being necessary. When the spillage monitoring system is replaced, only complete and original manufactures’ parts may be fitted.

4. Should the appliance turn itself off, wait for a minimum of 3 minutes before attempting to re-light. In the event of your stove tripping out, consult your installation engineer to have the flue / chimney checked.

© 2007-2008 Broseley Fires Ltd

TROUBLESHOOTING

THE GAS PILOT WILL NOT IGNITE OR STAY LIT

• Ensure the gas is turned on at the appliance and the meter / cylinder.

• Hold the pilot gas button for at lest 20 seconds once the pilot is alight to ensure the operation of the safety thermocouple valve.

• Ensure that the pilot injector is not obstructed or blocked and it is free from any dust or dirt.

• Ensure that the thermocouple has not been damaged in transit. This is a very delicate device.

• On bottled gas (LPG), check that the cylinder is not empty.

• Ensure that the aeration ring shutter on the pilot head is fully open so that the pilot flame is initially intense: this can be subsequently turned down.

• Ensure the pilot flame is the correct size for the type of gas. The flame should be focused on the thermocouple probe, so that it is evenly encircled.

• The pilot should have 3 flames. One directed towards the thermocouple, one towards the bed of the fire and the third towards the ignitor valve.

• Any whistling sound you hear is normally caused by dirt obstructing the pilot. This is normally cured by carrying out the cleaning process outlined in the next section entitled Servicing Instructions.

• After altering the pilot, check for any leakage of gas

THE MAIN BURNER DOES NOT SEEM TO BURN CORRECTLTY

• Ensure there is adequate gas pressure to the appliance. The pressure can be obtained by unscrewing the pressure test nipple and applying a suitable pressure gauge (I.E. A

MANOMETER). Be sure that the gas pressure agrees with the identification label on your stove.

• Ensure adequate volume of gas is being used. Once the fire is burning on maximum, turn off all other gas appliances in the house and calculate the fuel being burned from the gas meter.

• See that the burner is burning evenly across the whole of the mesh surface without any coals in place.

SERVICING INSTRUCTIONS

Servicing should be carried out annually by a qualified installation engineer when the stove is cold and the gas supply is turned off at the isolation tap. The following points should be checked.

• Remove the coals and clean any dust and debris from the top of the burner unit.

Ideally a vacuum cleaner should be used, but a soft brush will do.

• Check the condition of the coals. Any damaged ones will affect the efficient operation of the stove and should be replaced with new ones available from your stove supplier.

© 2007-2008 Broseley Fires Ltd

• All gas supply joints should be checked to make sure they are completely sealed and that the gas supply and pressure is to specification.

• The pilot jets are correctly set and clear of obstruction.

• The chimney should also be checked to make sure there are no restrictions or blockages.

• Finally re-lay the coals and re-light the stove as described previously.

CURING THE PAINT

Most high temperature paints operate in the same way. They use a resin which dries at room temperature and a silicon resin which cures at high temperatures. When the stove is burned the dry resin burns away and the silicon cures. This transition occurs about 475 degrees F.

After the stove burns about three times, the entire surface which gets hot will have cured.

The house needs to be fully ventilated during these initial burnings and although the smoke is mostly Carbon Dioxide there are other components of the smoke which make it smell bad and may irritate some people. These problems will go away after the first few burns depending of the duration and surface temperature of each burn. The hotter the stoves gets the more it will cure.

AND FINALLY……..

We would remind you that it is a legal requirement that the stove is installed by a qualified and accredited installation engineer. Improper installation, adjustment, alteration, service or maintenance can cause personal injury and / or damage to property.

If you are in the slightest doubt about any aspect of your stove’s performance or you require additional information then please contact your stove supplier, a qualified installation engineer or call our technical help-line on 01743 461444.

Please do not store, keep or use petrol or any other flammable liquids, vapours or substances anywhere near the stove or any other heating appliance.

We hope these instructions are clear and helpful and you are able to enjoy the full benefits of your stove. Please keep this booklet handy for future reference.

The materials used in building your gas stove are guaranteed for one year provided the assembly and operation complies with these instructions. Accidental damage and all consumables including the glass door seal are not covered.

We are sure you will appreciate and accept that our guarantee cannot be extended to cover the assembly, installation and the use of your stove as these are all operations outside our control or influence.

Please retain your purchase receipt. We will need to see this in the event of a claim under warranty.

© 2007-2008 Broseley Fires Ltd

STOVE INSTALLATION SPECIFICATION & INFORMATION

THIS SECTION TO BE COMPLETED AND SIGNED BY THE INSTALLATION

ENGINEER

TYPE OF GAS SUPPLY (please tick)

Natural (mains) Gas LPG supply in bulk LPG supply in cylinder

Size of Governor setting (i.e. Natural Gas 20 mbar. LPG 37 mbar)

Length and size of gas supply

Meter pressure. Fire on only

Other appliances. All on

Burner pressure. Fire on only

Other appliances. All on

Gas rate – Natural Gas – Time for 1 cubic foot in seconds

Type and size of flue

How much area of flue is left?

Is there any spillage?

Is there any ventilation in the room?

Has the room double-glazing?

Has the pilot sufficient heat to open the FFD?

Is the draught excessive?

Is the door close fitting?

Is the aeration of the pilot correct?

Is the FFD phial in the correct position in the pilot flame?

Does the flame encircle the FFD?

Installation Engineers Name

Address

Signed Date

© 2007-2008 Broseley Fires Ltd

Guarantee

Dear Customer,

Your decorative gas fire, when installed in accordance with the installation instructions and operated in accordance with these instructions should provide many years of safe and efficient operation.

We thank you for purchasing our product and trust it will provide excellent service.

This appliance carries a guarantee of 1 year. The consumable components of this appliance are guaranteed for one year.

We agree to repair free of charge or, at our option, replace the appliance or part thereof, which may prove to be defective within the guarantee period.

The guarantee is void if:

• The appliance is not installed and operated in accordance with our instructions; or

• The appliance is not serviced, by a CORGI registered engineer, annually; or

• Repairs of modification have been carried out by the purchaser or any third party not authorized by us; or

• The appliance has been misused or accidentally damaged; or

• Damage is due to ‘fair wear and tear’; or

• The appliance or defective component(s) are not returned to us, prepaid postage.

The rights given in this guarantee are limited to the UK mainland and are in addition to any to which you may have a statutory entitlement.

Please retain your purchase receipt. We will need to see this in the event of a claim under warranty.

Broseley Fires Ltd

Knights Way

Battlefield Enterprise Park

Shrewsbury

SY1 3AB

Telephone + 44 (0) 1743 461 444

Fax + 44 (0) 1743 461 446

© 2007-2008 Broseley Fires Ltd

advertisement

Key Features

  • Radiant convector fuel-effect
  • Class 1, 2 and pre-cast flue compatible
  • Less than 7kw, no additional ventilation required
  • Remote control operation
  • Spillage monitoring system
  • Permanent pilot light
  • Coal or log ceramic layout options

Frequently Answers and Questions

How do I light the permanent pilot light?
1. Depress the rear control knob fully. 2. Whilst depressed, turn knob sharply 90 degrees anti-clockwise to “pilot” setting. 3. Keep knob depressed at this point for 15-20 seconds. 4. Upon releasing, turn the knob anti-clockwise until it stops in the permanent pilot light position.
What is the proper ventilation requirement for the Winchester gas stove?
The stove is rated at less than 7kw and therefore does not normally require additional ventilation in the room.
What types of flues can I use with the Winchester gas stove?
The stove can use a class 1, class 2 and pre-cast flue.