IONTO-COMED IONTO-COMFORT XTENSION treatment couch Instruction manual
The IONTO-COMFORT XTENSION treatment couch is a fully automatic treatment couch which provides the highest level of operating and seating comfort. The couch is available in two versions: One version offers four powerful motors to adjust seat height and tilt angle, backrest and leg-rest. A second version offers 5 motors to additionally adjust the seat depth electrically. This means especially for taller persons a better distribution of body weight on the thighs and thereby maximum seat comfort. The adjustment of the seat depth is done with a switch. The settings are made with a programmable manual control. Three memory settings are available to store individual treatment positions. The 4-motor couch is available with or without integrated memory function. Head and footrest are extendable. The lowest seat entry as well as the tiltable arm rests offer a comfortable entry to the treatment couch. Furthermore two casters enable an easy movement of the couch. The treatment couch IONTO-COMFORT XTENSION can be used for all types of facial, body, footcare and massage treatments.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
IONTO-COMED
INSTRUCTION MANUAL
IONTO-COMFORT XTENSION BED
Art. No. 8460
Contents
Safety Instructions .......................................................................................................3
Fields of Use................................................................................................................4
Control Elements and Connections .............................................................................5
Installation ...................................................................................................................6
Operation IONTO-COMFORT XTENSION 4/4S (4-MOTORS) ...................................6
Set Reclining Position ............................................................................................. 6
Save Treatment Position (IONTO-Comfort Xtension 4S only) ................................ 7
Set Upholstery Heating (optional) ........................................................................... 8
Operation IONTO-COMFORT XTENSION 5S (5-MOTORS) ......................................9
Set Reclining Position ............................................................................................. 9
Save Treatment Position....................................................................................... 10
Set Upholstery Heating (optional) ......................................................................... 10
Cleaning and Care.....................................................................................................11
Repairs and Servicing ...............................................................................................11
Fault Finding and Solutions .......................................................................................12
Technical Data...........................................................................................................12
Transport/ Storage/ Operating Requirements............................................................13
Disposal.....................................................................................................................13
Delivery Contents ......................................................................................................13
Accessories ...............................................................................................................13
This instruction manual contains information intended to ensure safe operation of the treatment bed. Always keep it in close proximity where it is readily available for every user.
© IONTO-COMED 2010
IONTO-COMED GmbH
Durlacher Allee 109
D-76137 Karlsruhe
Telephone +49 (0) 721 / 97 70-0
Telefax +49 (0) 721 / 97 70-290
Email: [email protected] http://www.ionto.de
2 © by IONTO-COMED
Safety Instructions
Before installing and using the treatment bed, carefully read the instruction manual and ensure that all directions and instructions contained are fully understood. It includes important safety information for installation, operation and maintenance!
If the bed is used for any purpose other than that for which it was designed and as described in this instruction manual, such use will invalidate the manufacturers warranty and guarantee!
The control unit may only be opened by the manufacturer or by an expert approved and authorised by the manufacturer.
When unpacked, check the contents of the delivery to ensure that all parts have been included and that nothing has been damaged during transit. In the event of any doubt, please contact our customer service department.
Never use the bed with a damaged mains power supply cable. Do not jam or kink the cable and do not allow it to rest on any hot object (e.g. radiator, lamp, etc)!
If the mains cable is damaged in any way, immediately disconnect the bed from the mains power supply. Please consult our customer service department before using again.
Before connecting to the mains power supply ensure that the voltage (V) shown on the type plate corresponds with the power supply available!
Under no circumstances may the mains plug be disconnected from the socket with wet hands. Never attempt to remove the plug from the socket by pulling the connecting cable!
Do not use in damp surroundings and do not splash with liquid!
In the event of any liquid or foreign body entering the inner of the control unit, immediately disconnect the bed from the mains power supply! Please consult our customer service department before using again.
Always isolate from the mains power supply by disconnecting the mains plug before cleaning!
© by IONTO-COMED 3
Fields of Use
The IONTO-COMFORT XTENSION treatment bed is a fully automatic treatment bed which provides the highest level of operating and seating comfort. The bed is available in two versions: One version offers four powerful motors to adjust seat height and tilt angle, backrest and leg-rest. A second version offers 5 motors to additionally adjust the seat depth electrically. This means especially for taller persons a better distribution of body weight on the thighs and thereby maximum seat comfort.
The adjustment of the seat depth is done with a switch.
The settings are made with a programmable manual control. Three memory settings are available to store individual treatment positions. The 4-motor bed is available with or without integrated memory function. Head and footrest are extendable. The lowest seat entry as well as the tiltable arm rests offer a comfortable entry to the treatment bed. Furthermore two casters enable an easy movement of the bed.
The treatment bed IONTO-COMFORT XTENSION can be used for all types of facial, body, footcare and massage treatments.
4 © by IONTO-COMED
Control Elements and Connections
8
7
1
2
3
4
5
6
Legend
(1) Headrest
(2) Backrest
(3) Armrest
(4) Seat
(5) Legrest
(6) Footrest
(Seat depth adjustment)
Fig. 1: IONTO-Comfort Xtension
Bed
9
10
11
12
13
14
15
16
17
Fig. 3: Control of Seat Heating
Fig. 2: Manual Control
Legend
(10) Seat angle adjustment
(11) Legrest adjustment
(12) Seat height adjustment
(13) Program keys 1-3
(14) Memory key S
Legend
(15) ON/OFF Switch for Seat Heating (ON)
(16) Increase Heating Temperature (+)
(17) Lower Heating Temperature (-)
© by IONTO-COMED 5
Installation
1. Install the treatment bed:
) Stand the bed on a firm, level underground. The bed can be moved easily via casters.
) Insert the headrest into the mounting in the backrest.
2. Connect the treatment bed to the main voltage supply:
) Ensure that the mains power supply corresponds to the voltage (V) shown on the type plate.
) Plug the mains power plug into the mains socket.
3. Initialize the treatment bed:
The treatment bed must be initialized at the time of first operation to guarantee correct function.
) Press the memory key S and keep it pressed.
− After 10 seconds a pulsating acoustic tone will sound.
− All drives will move to their end position.
− Once the last drive has reached its end position, the acoustic tone will cease.
) Release pressure on the memory key S.
The treatment bed is now ready for use.
Operation IONTO-COMFORT XTENSION 4/4S (4-MOTORS)
Caution!
Risk of pinching!
The arms of the client must remain on the bed during adjustment of the reclining position.
Note
Do not allow that oil or any care products come in contact with the upholstery because this can damage it.
We recommend the use of an upholstery protection, e.g. a towelling cover.
If oil comes in contact with the upholstery, remove immediately.
Set Reclining Position
1. Armrest adjustment:
Caution!
Danger of injury!
Do not allow the armrests to fall downwards.
Both Armrests (3) can be folded downward.
) Raise the armrest lightly.
) Fold the armrest downwards.
Raise armrests:
) Lift the armrest.
) Fold the armrests back forward again.
2. Headrest adjustment:
The head rest (1) is removable and can be tilted to the front or back.
) Pull the headrest up vertically to the desired position.
6 © by IONTO-COMED
) Push the headrest forward or backward into the desired position.
3. Backrest adjustment:
The tilting angle of the backrest (2) can be adjusted.
) Press the left button in the first row on the manual control (9) to lift the back rest up front.
) Press the right button in the first row on the manual control (9) to lift the back rest back down.
4. Seat height adjustment:
The whole bed can be raised or lowered to the required height.
) Press the left key in the 2nd row (12) on the manual control to raise the bed.
) Press the right key in the 2nd row (12) on the manual control to lower the bed.
5. Seat adjustment:
The tilt angle of the whole bed can be adjusted (4).
) Press the left key in the 3rd row (10) on the manual control to tilt the seat angle backwards.
) Press the right key in the 3rd row on the manual control (10) to tilt the seat angle forward.
6. Legrest adjustment:
The legrest (5) can be adjusted independently of seat and backrest.
) Press the left key in the 4th row (11) on the manual control to raise the legrest.
) Press the right key in the 4th row (11) on the manual control to lower the legrest.
7. Footrest adjustment:
The footrest (6) can be extended.
Note
The footrest must be retracted when moving the bed into the entry seat height (lowest position).
) Pull out footrest until the desired position is reached.
) Push footrest back in.
Save Treatment Position (IONTO-Comfort Xtension 4S only)
1. To save the treatment position:
) Adjust the couch to the required position.
) Press the memory key S (14).
) Press the programming key 1, 2 or 3 (13) after a maximum of 1 second.
An acoustic tone will sound.
) After a maximum of 1 second press the memory key S again.
Two acoustic tones will sound.
) Release pressure on the memory key S.
The treatment position is saved.
Note
A new treatment position can replace a previously saved position.
2. Call-up a saved treatment position:
) Press the required program key 1, 2 or 3 (13).
Hold the key down until the bed has reached the programmed position.
© by IONTO-COMED 7
Set Upholstery Heating (optional)
1. Switch the upholstery heating on:
) Press the ON key (15) to switch the upholstery heating on. The control panel is located at the right side of the outer part of the back rest.
All blue LEDs (1-5) will light up.
) Set the required temperature with the (+/–) keys of the control panel.
) Press the (+) key (16) to increase the temperature.
The blue LEDs of the (1-5) keys will light up step by step.
) Press the (–) key (17) to decrease the temperature.
The blue LEDs (1-5) will extinguish gradually.
Note
For safety reasons, the upholstery heating will automatically switch OFF after 90 minutes of operation!
The upholstery heating can be switched ON again directly.
2. Switch the upholstery heating off:
) Press the ON key (15) to switch the upholstery heating off.
3. Switch the treatment bed off:
) Remove the mains power plug from the mains socket.
8 © by IONTO-COMED
Operation IONTO-COMFORT XTENSION 5S (5-MOTORS)
Caution!
Risk of pinching!
The arms of the client must remain on the couch during adjustment of the reclining position.
Note
Do not allow that oil or any care products come in contact with the upholstery because this can damage it.
We recommend the use of an upholstery protection, e.g. a towelling cover.
If oil comes in contact with the upholstery, remove immediately.
Set Reclining Position
1. Armrest adjustment:
Caution!
Danger of injury!
Do not allow the armrests to fall downwards.
Both Armrests (3) can be folded downward.
) Raise the armrest lightly.
) Fold the armrest downwards.
Raise armrests:
) Lift the armrest.
) Fold the armrests back forward again.
2. Headrest adjustment:
The headrest (1) is removable and can be tilted to the front or back.
) Pull the headrest up vertically to the desired position.
) Push the headrest forward or backward into the desired position.
3. Backrest adjustment:
The tilting angle of the backrest (2) can be adjusted.
) Press the left button in the first row on the manual control (9) to lift the back rest up front.
) Press the right button in the first row on the manual control (9) to lift the back rest back down.
4. Seat height adjustment:
The whole bed can be raised or lowered to the required height.
) Press the left key in the 2nd row (12) on the manual control to raise the bed.
) Press the right key in the 2nd row (12) on the manual control to lower the bed.
5. Seat adjustment:
The tilt angle of the whole bed can be adjusted both forwards and backwards (4).
) Press the left key in the 3rd row (10) on the manual control to tilt the seat angle backwards.
) Press the right key in the 3rd row on the manual control (10) to tilt the seat angle forward.
© by IONTO-COMED 9
6. Seat depth adjustment:
The seat (4) can be extended or shortened.
) Push the rocker switch (7) to the right to extend seat surface.
) Keep the switch pushed until you have reached the desired position.
) Push the rocker switch (7) to the left to shorten seat surface.
) Keep the switch pushed until you have reached the desired position.
7. Legrest adjustment:
The legrest (5) can be adjusted independently of seat and backrest.
) Press the left key in the 4th row (11) on the manual control to raise the legrest.
) Press the right key in the 4th row (11) on the manual control to lower the legrest.
8. Footrest adjustment:
The footrest (6) can be extended.
Note
The footrest must be retracted when moving the bed into the entry seat height (lowest position).
) Pull out footrest until desired position is reached.
) Push footrest back in.
Save Treatment Position
1. To save the treatment position:
) Adjust the couch to the required position.
) Press the memory key S (14).
) Press the programming key 1, 2 or 3 (13) after a maximum of 1 second.
An acoustic tone will sound.
) After a maximum of 1 second press the memory key S again.
Two acoustic tones will sound.
) Release pressure on the memory key S.
The treatment position is saved.
Note
A new treatment position can replace a previously saved position.
2. Call-up a saved treatment position:
) Press the required program key 1, 2 or 3 (13).
Hold the key down until the bed has reached the programmed position.
Set Upholstery Heating (optional)
1. Switch the upholstery heating on:
) Press the ON key to switch the upholstery heating on. The control panel is located at the right side of the outer part of the back rest.
All blue LEDs (1-5) will light up.
) Set the required temperature with the (+/–) keys of the control panel.
) Press the (+) key (16) to increase the temperature.
The blue LEDs of the (1-5) keys will light up step by step.
10 © by IONTO-COMED
) Press the (–) key (17) to decrease the temperature.
The blue LEDs (1-5) will extinguish gradually.
Note
For safety reasons, the upholstery heating will automatically switch OFF after 90 minutes of operation!
The upholstery heating can be switched ON again directly.
2. Switch the upholstery heating off:
) Press the ON key to switch the upholstery heating off.
3. Switch the treatment bed off:
) Remove the mains power plug from the mains socket.
Cleaning and Care
Caution!
Danger of electric shock!
Disconnect from the mains power supply before cleaning.
Note
Do not use any solvents, chloride, polish, synthetic cleaning agents, wax polish, aerosol sprays or aggressive cleaning agents which could cause damage to the upholstery or the bed.
Do not use any substances which contain oil or grease to clean the upholstery.
The upholstery is not resistant to chemical cleaning or dry-cleaning methods.
) Clean the upholstery with a cloth and warm water. We recommend microfiber material (art. no. 8299.61) or a cleansing glove (art. no. 9168.9).
) Dry upholstery after cleaning.
) Remove any stains from the upholstery with a mild cleanser.
) Remove obstinate stains with Incidin Foam (art. no. 4660). Carefully follow the
Directions for Use.
) Clean the frame of the bed and the manual control with a lightly moistened cloth.
Ensure that no water enters the control unit or the manual control.
) Wash the towelling cover at 60°C.
Repairs and Servicing
Your treatment bed does not require any special servicing when used correctly and in compliance with the manufacturer’s directions and instructions. However, in the event of any problem arising, please contact our customer service department.
Only persons authorised by the manufacturer may perform repairs. Any alterations or repairs performed by non-authorised persons will invalidate any guarantee, warranty or responsibility of the manufacturer. In addition, the safety of the treatment bed could be adversely affected.
© by IONTO-COMED 11
Fault Finding and Solutions
Fault Cause Solution
Automatic adjustment of the bed doesn’t function.
Voltage supply cable not connected correctly.
Check connection of the mains power cable. Mains power plug must be firmly inserted.
Treatment bed does not move to the saved treatment position.
Treatment bed not initialized.
Initialize treatment bed (see page 6) and afterwards recall saved treatment position. If needed treatment position has to be resaved.
Initialize again the treatment bed (see page 6).
Seat heating doesn’t function.
ON key is not pressed. Press ON key.
In the event of any other problem arising which is not dealt with above, please contact our customer service department (telephone number on the rear page).
Technical Data
Article number:
Operating voltage:
Power:
8460
230 V~ / 50-60 Hz
Xtension 4 (without Memory function): 180 W
Xtension 4S (with Memory function): 180 W
Xtension 5S (with Memory function): 180 W
Maximum weight on seat: 170 kg
Dimensions: Width with arm rests: 820 mm
Length: 1740 – 2130 mm
Seat height:
Seat depth:
530 – 980 mm
460 – 560 mm
12 © by IONTO-COMED
Transport/ Storage/ Operating Requirements
Transport only in the manufacturers original packaging.
Transport and storage temperature: -20 °C to +50 °C
Operating temperature:
Relative air humidity:
+10 °C to +40 °C max. 90 %, non-condensing
To avoid the formation of condensation, abrupt changes of temperature should be avoided. Wait until the treatment bed has acclimatised to the ambient temperature before putting into operation.
Disposal
Dispose of the packaging, treatment bed, upholstery and accessories in an environmentally friendly manner and in compliance with local regulations.
All electrical and electronic products should be disposed of separately from the municipal waste.
This crossed-out wheeled bin symbol on the product means the product is covered by the European Directive 2002/96/EC. The product should not be mixed with general household waste. There exists a separate collection system for these products.
The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health. It is a precondition for reuse and recycling of used electrical and electronic equipment.
Delivery Contents
1x Treatment Bed including padding
1x Manual Control
Accessories
Art. No. 4660 Incidin Foam, 750 ml
Art. No. 8299.61 Mikrofiber Cloth
Art. No. 8129.8
Art. No. 9168.9
Single-use Hygiene Clothes, 100 pcs.
Single-use Cleaning Gloves, 30 pcs.
For details of further accessories, please refer to the current IONTO-COMED catalogue.
© by IONTO-COMED 13
EG-KONFORMITÄTSERKLÄRUNG /
DECLARATION OF CONFORMITY
gemäß den Bestimmungen der EG-Richtlinie über / in accordance with the EU-Directives for
Elektromagnetische Verträglichkeit 2004/108/EG /
Electromagnetic Compatibility Directive 2004/108/EC
Elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen
2006/95/EG / Low Voltage Directive 2006/95/EC
Hersteller / Manufacturer:
Adresse / Address:
IONTO-COMED GmbH
Durlacher Allee 109
D-76137 Karlsruhe
Hiermit bestätigen wir, dass das Produkt /
We certifies that the product
Geräteart /
Purpose of equipment:
Universalbehandlungsliege /
Universal Treatment Couch
Gerätetyp / Type of equipment: IONTO-KOMFORT XTENSION LIEGE
Artikelnr. / Article no: 8460 mit obengenannten EG-Richtlinien übereinstimmt / is in accordance with the said EU-Directives.
Karlsruhe, 2010-03-01
IONTO-COMED GmbH
Manager
Martin La Fontaine
IONTO-COMED GmbH
Durlacher Allee 109 y D-76137 Karlsruhe
Telephone: +49 (0) 721 / 97 70-0 y Telefax: +49 (0) 721 / 97 70-290 http://www.ionto.de y Email: [email protected]
advertisement
Key Features
- Fully automatic treatment couch
- Adjustable seat height, tilt angle, backrest and leg-rest
- Optional electric seat depth adjustment
- Programmable manual control
- Three memory settings
- Extendable headrest and footrest
- Tiltable arm rests
- Casters for easy movement