Below you will find brief information for DC Regulated Power Supply EP-600 EP-601, DC Regulated Power Supply EP-600 EP-603, DC Regulated Power Supply EP-600 EP-611, DC Regulated Power Supply EP-600 EP-613. This manual provides instructions on how to safely and effectively use these power supplies. The unit offers overload and short circuit protection, independent 5V and 12V output terminals (EP-603 & EP-613), adjustable voltage and current, and screw-on output terminals for connecting your devices. It also includes safety precaution information that should be reviewed before operating the unit. The unit should be placed in a well-ventilated location and should not be used for equipment that requires higher current ratings than the unit is designed for.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

EP-600 Series DC Regulated Power Supply User's Manual | Manualzz

EP-600 SERIES DC REGULATED POWER SUPPLY

USER’S MANUAL

I.

GENERAL

EP-600 Series DC Regulated Power Supply is a completely solid state, compact, well regulated, constant voltage power supply suitable for service field, hobby & general use. For safety purpose, a three-wire power cord is provided.

II.

FEATURES

1.

Overload and Short Circuit Protection: Prevent the unit from overload and short circuit.

When the unit is under the condition of overload or short circuit, the output current will be limited.

2.

Independent 5V, 12V Easy Snap-On fixed output terminals (EP-603 & EP-613 only) to make it easy to use for TTL and CMOS circuit test. The grounding of the output terminals is independent that the output can be connected in series to make a higher output voltage.

III. FRONT AND REAR PANELS

3 4 5 11 10

6

7

8

9

2

1

1. ON/OFF Switch

2. Power Indicator

3. Voltmeter

4. Ammeter

5. Current Limited Indicator

6. Easy Snap-On Output Terminals

IV. OPERATION

7. Screw-On Output Terminal

8. Voltage Adjustment Knob

9. Current Adjustment Knob

10. Fuse Holder

11. Power Cord

A.

Installation:

1.

Place the unit in a location where allows free air circulation.

2.

DO NOT place the unit in high humid, dusty and/or sunshiny places.

3.

The input power source must be

±5% of the rated input voltage.

B.

Caution:

1.

DO NOT use the unit for equipment that requires higher current ratings than the unit is designed for, otherwise damage could occur to the unit.

2.

DO NOT replace the fuse before ceasing the problems and assigned value of fuse must be used in place.

C.

Safety Precautions:

The following precautions MUST be read carefully to prevent from electric shock.

1.

NEVER remove the metal cover of the power supply while power source is connecting.

2.

NEVER touch the power supply when your hand is wet.

3.

NEVER operate the power supply if foreign materials such as metallic objects, water or other debris have fallen inside. Contact your dealer for check and repair.

4.

NEVER operate the unit that was being damaged. As the voltage regulation circuitry may have been disabled, the resulting high DC voltage could cause damage to your equipment.

5.

NEVER allow foreign objects to touch the output terminals.

6.

If you have the need to inspect the interior of the power supply, be contained to let it cool down completely, as some components may be hot enough to burn your hands in event of component failure (People other than professions are not recommend to check the interior yourselves.)

D.

Connection and Operation:

1.

Turn OFF the unit and the equipment.

2.

Connect the equipment to the unit. Positive polarity to red (

+) and negative polarity to

Black (

−).

3.

Turn ON the unit first and then turn ON the equipment.

4.

When an operation is finished, turn OFF the equipment first and then turn OFF the unit.

V.

SPECIFICATIONS

MODEL NUMBER:

OUTPUT VOLTAGE:

OUTPUT CURRENT:

RIPPLE & NOISE:

LINE REGULATION:

LOAD REGULATION:

FIXED VOLTAGE 1:

FIXED VOLTAGE 2:

POWER SOURCE:

METERS TYPE:

DIMENSION (W

×H×D):

WEIGHT:

ACCESSORY:

EP-601 EP-603

0-30V DC

EP-611

2.5A

5mV r.m.s.

0.05% + 10mV

EP-613

Nil

Nil

0.05% + 10mV

5V/0.5A

12V/0.5A

Nil

Nil

5V/0.5A

12V/0.5A

230Vac/50Hz (120Vac/60Hz or on request)

ANALOG METERS LCD METERS

150

× 145 × 200 (mm)

2.8 Kg (Approx.)

Instruction Book

7673-0600-0001

advertisement

Key Features

  • Overload and short circuit protection
  • Independent 5V/12V outputs (EP-603 & EP-613)
  • Adjustable voltage and current
  • Screw-on output terminals
  • Analog/LCD Meters

Frequently Answers and Questions

What is the purpose of the Current Limited Indicator?
The Current Limited Indicator lights up when the unit is under the condition of overload or short circuit. This indicates that the output current is being limited to protect the unit.
Can I connect the output terminals in series to get a higher output voltage?
Yes, the grounding of the Easy Snap-On output terminals (EP-603 & EP-613) is independent. This allows you to connect the outputs in series to achieve a higher output voltage.
What are the safety precautions I should follow when using this power supply?
Always unplug the unit before making any adjustments or connections. Never touch the power supply with wet hands. Never operate the unit if any foreign objects have fallen inside. Never operate a damaged unit.