Guia de Instalação PWS6400

Guia de Instalação PWS6400
Installation Guide
1
Safety Precautions
Dismantling and Scrapping
Both the installer, the owner, and the operator of this PWS must read and understand this installation manual.
General
–
–
–
–
–
–
–
–
–
–
–
–
Only qualified personnel may install or operate the PWS.
The PWS must be installed according to the installation instructions.
The PWS is designed for stationary installation on a plane surface, where the following conditions are fulfilled:
• no high explosive risks
• no strong magnetic fields
• no direct sunlight
• no large, sudden temperature changes
• for use in Pollution Degree 2 Environment
• for use on the flat surface of a Type 1 enclosure
Never allow fluids, metal filings or wiring debris to enter any openings in the PWS. This may cause fire or
electrical shock.
The PWS fulfills the requirements of EMC directive 2004/108/EC.
Storing the PWS where the temperature is lower/higher than recommended in this manual can cause the
LCD display liquid to congeal/become isotopic.
The LCD display liquid contains a powerful irritant. In case of skin contact, wash immediately with plenty
of water. In case of eye contact, hold the eye open, flush with plenty of water and get medical attention.
The supplier is not responsible for modified, altered or reconstructed equipment.
Use only parts and accessories manufactured according to specifications of the supplier.
Peripheral equipment must be appropriate for the application and location.
The figures in this manual serves an illustrative purpose. Because of the many variables associated with any
particular installation, the supplier cannot assume responsibility for actual use based on the figures.
The supplier neither guarantees that the PWS is suitable for your particular application, nor assumes responsibility for your product design, installation or operation.
Power Source
–
–
The PWS is equipped with a 24 V DC input. Supply power other than 24 V DC ± 15% will severely damage the PWS. Thus, check the power supply supporting the DC power regularly.
To avoid electric shock, be sure the power cable is unplugged from the power outlet when connecting the
cable to the PWS.
–
–
The PWS or parts thereof shall be recycled according to local regulations.
The following components contain substances that might be hazardous to health and the environment:
lithium battery, electrolytic capacitor and display.
Note:
Indicated loss of life, severe personal injury, or substantial property damage
will result if proper precautions are not taken.
!
2
Without grounding, the PWS may be severely affected by excess noise. Make sure that the grounding is
done properly from the power connector at the rear side of the PWS. When power is connected, make sure
that the wire is grounded.
–
Use a cable of at least 2 mm2 (AWG 14) to ground the PWS. Ground resistance must be less than 100
Ohms (class3). Note that the ground cable must not be connected to the same ground point as the power
circuit.
Steps to wire
1 x PWS
1 x Power Connector
(wired to the power supply )
3
1.
2.
1.
2.
Unplug the power connector and unscrew the screws.
Strip about 7-8 mm of insulation. Insert the wire all the way into the power connector and then turn the
screws tight.
3.
Plug in the connector to the power input of the PWS.
Note:
Power connector is already plugged in the power input of the PWS when the package is first
opened.
Mounting Procedure
Cut out the control front panel to match the dimensions (mm) specified under the External and Cut-out
dimensions chapter.
Mount the PWS into the cut-out. Insert the fixtures to the holes on the unit and fasten the screws into
the front panel. Do not tighten the screws with too much or uneven force, or it may cause deformation
of the PWS.
STEP 1
STEP 2
STEP 3
Communication cables must be separated from the power cables for operational circuits. Use shielded cables or it may cause unpredictable problems.
-
FG
DC 24V
Emergency stop and other safety functions may not be controlled from the PWS.
Do not use force or sharp objects when touching the keys, display etc.
135º
Use Copper Conductors Only
sp
la
y
135º
Di
Only qualified personnel should carry out repairs.
Before carrying out any cleaning or maintenance operations, disconnect the equipment from the electrical
supply.
Clean the display and surrounding front cover with a soft cloth and mild detergent.
Replacing the battery incorrectly may result in explosion. Only use batteries recommended by the supplier.
Max torque: 0.35-0.5 Nm (3.1-4.43 lb-in)
Description of Parts
0º
Display
3.
7
Power Supply and Wiring
+
–
–
CUTOUT DIMENSION
Warning:
To avoid an electric shock, be sure to switch off the power before connecting the communication/download cable to the PWS.
Service and Maintenance
–
–
External and Cut-out Dimensions
The PWS must use a power supply with 24 V DC and the power consumption is 4W.
During Use
–
–
6
–
5
4 x Installation Fasteners
Grounding
Make sure that the PWS works properly. To prevent it from radiating radio frequency noise, the PWS must be
connected to earth ground.
Package Contents
Installation
–
4
Product Specifications
9
–
Item
Display Type
Power lamp
Communication lamps
Display
I/O Fixture holes
Expansion I/O port
Dip Switches
1-10
Wire Gauge
(AWG)
Stripped Length
Torque
Solid
28-12
7-8 mm
4.5 lb-in
Stranded
30-12
7-8 mm
4.5 lb-in
The PWS must be installed within an angle of 0° to 135° as shown above.
8
Fixture mounting
holes
Type
PWS6400F-S
PWS6400F-P
Mono STN LCD
Display Color
16 shades of blue
Display size
3.3” (diagonal); display area is 58.5 x 58.5mm
Display resolution
240 x 240, Number of 8 x 8 characters displayable 30 x 30
Display adjustment
Via touch panel
Back light
LED, Lifetime 10,000 hours @ 25 ° C
Touch Screen
Analog
Input Power
24 V DC +-15%, under 4W
Flash ROM
4 Mb
RAM
512 K byte
Communication Ports
10 Dip Switches
COM 1 is a 9-pin female connector used to connect a controller and the PWS via RS232, RS422 or
RS485. Only COM1 is used to download.
Please make sure that the connection is in accordance with the setting of the dip switches.
For illustration on the connection between the PWS and a controller, please consult the information on the controller.
COM 1
5 4
3 2 1
9 8 7 6
PIN
Function
CPU
32 bits RISC
1
RS422 TX+(RS485+)
Battery backed memory
-
2
RS232 RXD
3
RS232 TXD
4
RS422 RX+
5
Signal ground
6
RS422 TX-(RS485-)
Dip Switches
SW 1
Function
Reserved
SW 2
Reserved
SW 3
SW 4
Operation Mode
ON
ON
Runs user application
ON
OFF
Runs burn-in test program
OFF
ON
Updates BIOS
OFF
OFF
Runs bench test program
SW 5
Communication Parameters
ON
The PWS uses parameters defined on the Configuration Screen for controller communications
OFF
The PWS uses parameters defined in ADP for controller communications
SW 6
Password
ON
The PWS asks the operator to enter a password after power-on self-test
OFF
No password is required to start the PWS
SW 7
System Menu
ON
The PWS displays System Menu
RTC
YES (rechargeable lithium battery)
Data/Recipe
-
Data storage (CF Card)
-
Expansion I/O port
-
COM1
9-pin female, RS232,RS422 and RS485
7
RS232 RTS
COM2
-
8
RS232 CTS
COM3
-
9
RS422 RX-
ON
The default user level is set to 1 if the PWS requires no password to start its operation
USB Master
-
OFF
The default user level is set to 9 if the PWS requires no password to start its operation
USB Device
-
SW 9
COM1 Port
Ethernet
-
ON
For RS485: this switch has to be set ON
Front Panel seal
IP65
OFF
For RS422: this switch has to be set OFF
Ambient temperature
0° - 50° C
SW 10
Reserved
Storage temperature
-10° - 60° C
8 K byte
Yes
Ambient humidity
10-90%RH(0~40° C),10-60%RH(41~50° C),(non-condensing)
Vibration endurance
0.5 mm displacement, 10-55 Hz, 2 hours per X, Y, Z axis directions
Shock endurance
10 G, 11 ms three times in each direction of X, Y, Z axes
CE
EN61000-6-4,EN61000-6-2
External dimensions
96 x 96 x 40.6mm
Cut-out dimensions
89.3 x 89.3mm
Weight
0.47 kg
Cooling
Natural cooling
OFF
The PWS runs user application without displaying System Menu
SW 8
Default user level
Note:
When using the PWS for the first time, remember to reset Real Time Clock (RTC).
DC Power
Input
COM1 (RS232, RS422,RS485)
Beijer Electronics AB
Box 426
SE-201 24 Malmö, Sweden
Tel: +46 40 35 86 00
Fax: +46 40 93 23 01
www.beijerelectronics.com
Hitech Electronics Corp.
7-8F, No. 108, Minchiuan Road
Shin-Tien, Taipei Shien, Taiwan, R.O.C.
Tel: +886-2-2218-3600
Fax: +886-2-2218-9547
www.hitechsite.com
05/27/2009/V.2 640018+05
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement