R&S®ZVA Vector Network Analyzer Specifications

R&S®ZVA Vector Network Analyzer Specifications
ZVA_dat-sw_en_5213-5680-22_cover.indd 1
Data Sheet | 12.00
Test & Measurement
R&S®ZVA
Vector Network Analyzer
Specifications
02.07.2014 10:22:26
Version 12.00, July 2014
CONTENTS
Definitions ....................................................................................................................................................................... 3
Specifications .................................................................................................................................................................. 4
Measurement range .......................................................................................................................................................................... 4
Measurement speed .......................................................................................................................................................................... 8
Measurement accuracy ................................................................................................................................................................... 10
Effective system data....................................................................................................................................................................... 19
Test port output ............................................................................................................................................................................... 21
Test port input ................................................................................................................................................................................. 25
Additional front panel connectors ..................................................................................................................................................... 29
Optional front panel connectors ....................................................................................................................................................... 29
Display ............................................................................................................................................................................................ 29
Rear panel connectors..................................................................................................................................................................... 29
Options .......................................................................................................................................................................... 31
General data .................................................................................................................................................................. 35
Ordering information .................................................................................................................................................... 36
2
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
Version 12.00, July 2014
Definitions
General
Product data applies under the following conditions:




Three hours storage at ambient temperature followed by 90 minutes warm-up operation
Specified environmental conditions met
Recommended calibration interval adhered to
All internal automatic adjustments performed, if applicable
Specifications with limits
Represent warranted product performance by means of a range of values for the specified parameter. These specifications are
marked with limiting symbols such as <, ≤, >, ≥, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by
testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift
and aging, if applicable.
Specifications without limits
Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent
values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is
ensured by design.
Typical data (typ.)
Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a
range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the
mean value.
Nominal values (nom.)
Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to
typical data, a statistical evaluation does not take place and the parameter is not tested during production.
Measured values (meas.)
Characterize expected product performance by means of measurement results gained from individual samples.
Uncertainties
Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been
calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account
environmental conditions, aging, wear and tear.
Device settings and GUI parameters are indicated as follows: “parameter: value”.
Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz.
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
3
Version 12.00, July 2014
Specifications
Unless otherwise stated, specifications apply to test ports and a nominal source power of –10 dBm.
Measurement range
Impedance
Test port connector
Number of test ports
Frequency range
Static frequency accuracy
Frequency resolution
Number of measurement points
Number of traces
Measurement bandwidths
Dynamic range of the R&S®ZVA8
(without optional step attenuators
and without optional direct
generator/receiver access)
Dynamic range of the R&S®ZVA24
(without optional step attenuators
and without optional direct
generator/receiver access)
Dynamic range of the R&S®ZVA40
(without optional step attenuators
and without optional direct
generator/receiver access)
Dynamic range of the R&S®ZVA50
(without optional step attenuators
and without optional direct
generator/receiver access)
50 Ω
type N, female
3.5 mm, male, ruggedized
2.92 mm, male, ruggedized
2.4 mm, male, ruggedized
2.4 mm, male, ruggedized
1.85 mm, male, ruggedized
2 or 4
R&S®ZVA8
300 kHz to 8 GHz
R&S®ZVA24
10 MHz to 24 GHz
R&S®ZVA40
10 MHz to 40 GHz
R&S®ZVA50
10 MHz to 50 GHz
R&S®ZVA67
10 MHz to 67 GHz
without optional oven quartz
8×10–6
with optional oven quartz
1×10–7
1 Hz
user-selectable
1 to 60001
per diagram area
20
1/2/5 steps
1 Hz to 1 MHz 1
from PORT 1 to PORT 2 and from PORT 3 to PORT 4
300 kHz to 50 MHz
> 100 dB, typ. 110 dB
50 MHz to 100 MHz
> 120 dB, typ. 130 dB
100 MHz to 4 GHz
> 130 dB, typ. 140 dB
4 GHz to 7 GHz
> 125 dB, typ. 135 dB
7 GHz to 8 GHz
> 120 dB, typ. 130 dB
from PORT 1 to PORT 2 and from PORT 3 to PORT 4
10 MHz to 100 MHz
> 90 dB, typ. 105 dB 2
100 MHz to 700 MHz
> 105 dB, typ. 120 dB
700 MHz to 2 GHz
> 125 dB, typ. 130 dB
2 GHz to 13 GHz
> 130 dB, typ. 135 dB
13 GHz to 24 GHz
> 125 dB, typ. 130 dB
from PORT 1 to PORT 2 and from PORT 3 to PORT 4
10 MHz to 50 MHz
> 90 dB, typ. 100 dB 2
50 MHz to 500 MHz
> 105 dB, typ. 115 dB
500 MHz to 2 GHz
> 125 dB, typ. 135 dB
2 GHz to 20 GHz
> 130 dB, typ. 140 dB
20 GHz to 24 GHz
> 125 dB, typ. 135 dB
24 GHz to 32 GHz
> 120 dB, typ. 130 dB
32 GHz to 40 GHz
> 118 dB, typ. 125 dB
from PORT 1 to PORT 2 and from PORT 3 to PORT 4
10 MHz to 50 MHz
> 90 dB, typ. 100 dB
50 MHz to 500 MHz
> 105 dB, typ. 115 dB
500 MHz to 2 GHz
> 125 dB, typ. 135 dB
2 GHz to 20 GHz
> 130 dB, typ. 140 dB
20 GHz to 24 GHz
> 125 dB, typ. 135 dB
24 GHz to 40 GHz
> 120 dB, typ. 130 dB
40 GHz to 45 GHz
> 115 dB, typ. 125 dB
45 GHz to 50 GHz
> 110 dB, typ. 120 dB
R&S®ZVA8
R&S®ZVA24
R&S®ZVA40
R&S®ZVA40
R&S®ZVA50
R&S®ZVA67
1
With R&S®ZVA-K17 option: 1 Hz to 5 MHz.
2
R&S®ZVA24 and R&S®ZVA40 with four ports, four sources: 10 MHz to 20 MHz: > 70 dB.
4
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
Version 12.00, July 2014
Dynamic range of the R&S®ZVA67
(without optional step attenuators
and without optional direct
generator/receiver access)
from PORT 1 to PORT 2 and from PORT 3 to PORT 4
10 MHz to 50 MHz
> 70 dB, typ. 90 dB
50 MHz to 500 MHz
> 110 dB, typ. 125 dB
500 MHz to 2 GHz
> 125 dB, typ. 135 dB
2 GHz to 24 GHz
> 130 dB, typ. 140 dB
24 GHz to 32 GHz
> 120 dB, typ. 130 dB
32 GHz to 40 GHz
> 115 dB, typ. 125 dB
40 GHz to 50 GHz
> 115 dB, typ. 125 dB
50 GHz to 65 GHz
> 107 dB, typ. 115 dB
65 GHz to 67 GHz
> 105 dB, typ. 115 dB
67 GHz to 70 GHz
typ. 103 dB
Dynamic range at optional measurement
input (direct generator/receiver access
option) of the R&S®ZVA8
from PORT 1 to MEAS 2 IN
300 kHz to 10 MHz
10 MHz to 100 MHz
100 MHz to 8 GHz
from PORT 1 to MEAS 2 IN
10 MHz to 100 MHz
100 MHz to 13 GHz
13 GHz to 20 GHz
20 GHz to 24 GHz
from PORT 1 to MEAS 2 IN
10 MHz to 100 MHz
100 MHz to 20 GHz
20 GHz to 24 GHz
24 GHz to 32 GHz
32 GHz to 40 GHz
from PORT 1 to MEAS 2 IN
10 MHz to 100 MHz
100 MHz to 20 GHz
20 GHz to 24 GHz
24 GHz to 32 GHz
32 GHz to 40 GHz
40 GHz to 50 GHz
from PORT 1 to MEAS 2 IN
10 MHz to 100 MHz
100 MHz to 20 GHz
20 GHz to 24 GHz
24 GHz to 32 GHz
32 GHz to 40 GHz
40 GHz to 50 GHz
50 GHz to 67 GHz
Dynamic range at optional measurement
input (direct generator/receiver access
option) of the R&S®ZVA24
Dynamic range at optional measurement
input (direct generator/receiver access
option) of the R&S®ZVA40
Dynamic range at optional measurement
input (direct generator/receiver access
option) of the R&S®ZVA50
Dynamic range at optional measurement
input (direct generator/receiver access
option) of the R&S®ZVA67
typ. > 125 dB
typ. > 135 dB
typ. > 145 dB
typ. > 135 dB
typ. > 145 dB
typ. > 140 dB
typ. > 130 dB
typ. > 140 dB
typ. > 150 dB
typ. > 140 dB
typ. > 130 dB
typ. > 120 dB
typ. > 140 dB
typ. > 150 dB
typ. > 145 dB
typ. > 140 dB
typ. > 135 dB
typ. > 130 dB
typ. > 140 dB
typ. > 145 dB
typ. > 145 dB
typ. > 140 dB
typ. > 135 dB
typ. > 130 dB
typ. > 125 dB
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
5
Version 12.00, July 2014
Dynamic range in dB versus frequency in GHz of the R&S®ZVA8.
Dynamic range in dB versus frequency in GHz of the R&S®ZVA24.
Dynamic range in dB versus frequency in GHz of the R&S®ZVA40.
6
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
Version 12.00, July 2014
Dynamic range in dB versus frequency in GHz of the R&S®ZVA50.
Dynamic range in dB versus frequency in GHz of the R&S®ZVA67.
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
7
Version 12.00, July 2014
Measurement speed
Measurement time per point
Data transfer time
Switching time between channels
Switching time between two preloaded
instrument settings
CW mode,
1 MHz measurement bandwidth
for 201 measurements points
via IEC/IEEE bus
via VX11 over 100 Mbit/s LAN
via RSIB over 100 Mbit/s LAN
with no more than 2001 points
with no more than 2001 points
< 3.5 µs
< 2.9 ms
< 1.3 ms
< 0.7 ms
< 1 ms
< 10 ms
Sweep times of the R&S®ZVA8, R&S®ZVA24, R&S®ZVA40 and R&S®ZVA50
Sweep times depend on the number of measurement points, the measurement bandwidth and the start and stop frequencies.
They include times for retrace and internal band switching and are valid with ALC and display switched off.
Number of measurement points 51
101
201
401
801
1601
R&S®ZVA with start frequency 5 GHz, stop frequency 5.2 GHz
For a measurement bandwidth of 100 kHz
With full one-port calibration or
with correction switched off
2.6 ms
4.0 ms
6.8 ms
12 ms
23 ms
42 ms
With TOSM calibration
3.8 ms
6.5 ms
11.6 ms
22 ms
41 ms
124 ms
For a measurement bandwidth of 1 MHz
With full one-port calibration or
with correction switched off
2.1 ms
3.0 ms
4.7 ms
8.0 ms
15 ms
26 ms
With TOSM calibration
2.8 ms
4.5 ms
7.5 ms
14 ms
26 ms
94 ms
R&S®ZVA with start frequency 6 GHz, stop frequency 8 GHz
For a measurement bandwidth of 100 kHz
With full one-port calibration or
with correction switched off
3.6 ms
6.4 ms
With TOSM calibration
4.8 ms
8.9 ms
For a measurement bandwidth of 1 MHz
With full one-port calibration or
with correction switched off
3.1 ms
5.4 ms
With TOSM calibration
3.8 ms
6.8 ms
R&S®ZVA8 with start frequency 10 MHz, stop frequency 8 GHz
R&S®ZVA24 with start frequency 10 MHz, stop frequency 24 GHz
R&S®ZVA40 with start frequency 10 MHz, stop frequency 40 GHz
R&S®ZVA50 with start frequency 10 MHz, stop frequency 50 GHz
For a measurement bandwidth of 100 kHz
With full one-port calibration or
with correction switched off
8.6 ms
13 ms
With TOSM calibration
9.9 ms
15.5 ms
For a measurement bandwidth of 1 MHz
With full one-port calibration or
with correction switched off
8.2 ms
12 ms
With TOSM calibration
8.8 ms
13.4 ms
8
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
11.5 ms
16.3 ms
19 ms
29 ms
31 ms
49 ms
50 ms
132 ms
9.4 ms
12.2 ms
14.7 ms
20.5 ms
23 ms
33 ms
35 ms
103 ms
19.4 ms
25 ms
32 ms
41 ms
55 ms
74 ms
92 ms
173 ms
17.4 ms
20.2 ms
28 ms
33 ms
47 ms
57 ms
75 ms
143 ms
Version 12.00, July 2014
Sweep times of the R&S®ZVA67
Sweep times depend on the number of measurement points, the measurement bandwidth and the start and stop frequencies.
They include times for retrace and internal band switching and are valid with ALC and display switched off. Furthermore the
“Channel: Mode: Alternating Sweeps” must be activated.
Number of measurement points
51
101
201
401
801
1601
R&S®ZVA67 with start frequency 6 GHz, stop frequency 12 GHz
For a measurement bandwidth of 100 kHz
With full one-port calibration or
with correction switched off
2 ms
3 ms
6 ms
11 ms
21 ms
42 ms
With TOSM calibration
4 ms
6 ms
12 ms
22 ms
42 ms
125 ms
For a measurement bandwidth of 1 MHz
With full one-port calibration or
with correction switched off
1.5 ms
2 ms
4 ms
7 ms
13 ms
25 ms
With TOSM calibration
3 ms
4 ms
8 ms
14 ms
26 ms
90 ms
R&S®ZVA67 with start frequency 10 MHz, stop frequency 67 GHz
For a measurement bandwidth of 100 kHz
With full one-port calibration or
with correction switched off
3 ms
4 ms
With TOSM calibration
6 ms
8 ms
For a measurement bandwidth of 1 MHz
With full one-port calibration or
with correction switched off
2.5 ms
3 ms
With TOSM calibration
5 ms
6 ms
7 ms
14 ms
12 ms
24 ms
22 ms
44 ms
42 ms
125 ms
5 ms
10 ms
8 ms
16 ms
14 ms
28 ms
25 ms
90 ms
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
9
Version 12.00, July 2014
Measurement accuracy
This data is valid between +18 °C and +28 °C, provided the temperature has not varied by more than 1 K after calibration. Validity of
the data is conditional on the use of a suitable calibration kit. This calibration kit is used to achieve the effective system data specified
below. Frequency points, measurement bandwidth and sweep time have to be identical for measurement and calibration (no
interpolation allowed).
Accuracy of transmission measurements
R&S®ZVA8
300 kHz to 1 MHz
for +15 dB to –45 dB
1 MHz to 50 MHz
for +15 dB to –30 dB
for –30 dB to –45 dB
50 MHz to 8 GHz
for +15 dB to +5 dB
for +5 dB to –55 dB
for –55 dB to –70 dB
for –70 dB to –85 dB
R&S®ZVA24
10 MHz to 50 MHz
for +15 dB to –30 dB
50 MHz to 400 MHz
for +15 dB to –30 dB
for –30 dB to –45 dB
400 MHz to 700 MHz
for +15 dB to –50 dB
for –50 dB to –65 dB
700 MHz to 24 GHz
for +15 dB to +5 dB
for +5 dB to –55 dB
for –55 dB to –70 dB
for –70 dB to –85 dB
R&S®ZVA40
10 MHz to 50 MHz
for +15 dB to –30 dB
50 MHz to 250 MHz
for +15 dB to –30 dB
for –30 dB to –45 dB
250 MHz to 700 MHz
for +15 dB to +5 dB
for +5 dB to –65 dB
for –65 dB to –80 dB
700 MHz to 2 GHz
for +15 dB to +5 dB
for +5 dB to –50 dB
for –50 dB to –65 dB
for –65 dB to –80 dB
2 GHz to 24 GHz
for +15 dB to +5 dB
for +5 dB to –55 dB
for –55 dB to –70 dB
for –70 dB to –85 dB
24 GHz to 32 GHz
for +15 dB to +5 dB
for +5 dB to –45 dB
for –45 dB to –60 dB
for –60 dB to –75 dB
32 GHz to 40 GHz
for +15 dB to +5 dB
for +5 dB to –40 dB
for –40 dB to –55 dB
for –55 dB to –70 dB
10
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
< 1 dB or < 6°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 0.2 dB or < 2°
< 0.1 dB or < 1°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 1 dB or < 6°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 0.2 dB or < 2°
< 0.1 dB or < 1°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 1 dB or < 6°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 0.3 dB or < 3°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 0.3 dB or < 3°
< 0.1 dB or < 1°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 0.3 dB or < 3°
< 0.1 dB or < 1°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 0.3 dB or < 3°
< 0.2 dB or < 2°
< 0.3 dB or < 3°
< 1 dB or < 6°
< 0.4 dB or < 4°
< 0.2 dB or < 2°
< 0.4 dB or < 4°
< 1 dB or < 6°
Version 12.00, July 2014
R&S®ZVA50
10 MHz to 50 MHz
50 MHz to 250 MHz
250 MHz to 700 MHz
700 MHz to 2 GHz
2 GHz to 24 GHz
24 GHz to 32 GHz
32 GHz to 40 GHz
40 GHz to 50 GHz
for +15 dB to –30 dB
for +15 dB to –30 dB
for –30 dB to –45 dB
for +15 dB to +5 dB
for +5 dB to –65 dB
for –65 dB to –80 dB
for +15 dB to +5 dB
for +5 dB to –50 dB
for –50 dB to –65 dB
for –65 dB to –80 dB
for +15 dB to +5 dB
for +5 dB to –55 dB
for –55 dB to –70 dB
for –70 dB to –85 dB
for +15 dB to +5 dB
for +5 dB to –45 dB
for –45 dB to –60 dB
for –60 dB to –75 dB
for +15 dB to +5 dB
for +5 dB to –40 dB
for –40 dB to –55 dB
for –55 dB to –70 dB
for +15 dB to +5 dB
for +5 dB to –35 dB
for –35 dB to –50 dB
for –50 dB to –65 dB
< 1 dB or < 6°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 0.3 dB or < 3°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 0.3 dB or < 3°
< 0.1 dB or < 1°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 0.3 dB or < 3°
< 0.1 dB or < 1°
< 0.2 dB or < 2°
< 1 dB or < 6°
< 0.3 dB or < 3°
< 0.2 dB or < 2°
< 0.3 dB or < 3°
< 1 dB or < 6°
< 0.4 dB or < 4°
< 0.2 dB or < 2°
< 0.4 dB or < 4°
< 1 dB or < 6°
< 0.4 dB or < 4°
< 0.2 dB or < 2°
< 0.4 dB or < 4°
< 1 dB or < 6°
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
11
Version 12.00, July 2014
R&S®ZVA67
10 MHz to 50 MHz
50 MHz to 250 MHz
for +15 dB to –30 dB
< 1 dB or < 6°
for +15 dB to –30 dB
< 0.2 dB or < 2°
for –30 dB to –45 dB
< 1 dB or < 6°
250 MHz to 700 MHz
for +15 dB to +5 dB
< 0.3 dB or < 3°
for +5 dB to –65 dB
< 0.2 dB or < 2°
for –65 dB to –80 dB
< 1 dB or < 6°
700 MHz to 2 GHz
for +15 dB to +5 dB
< 0.3 dB or < 3°
for +5 dB to –50 dB
< 0.1 dB or < 1°
for –50 dB to –65 dB
< 0.2 dB or < 2°
for –65 dB to –80 dB
< 1 dB or < 6°
2 GHz to 24 GHz
for +15 dB to +5 dB
< 0.3 dB or < 3°
for +5 dB to –55 dB
< 0.1 dB or < 1°
for –55 dB to –70 dB
< 0.2 dB or < 2°
for –70 dB to –85 dB
< 1 dB or < 6°
24 GHz to 32 GHz
for +15 dB to +5 dB
< 0.3 dB or < 3°
for +5 dB to –45 dB
< 0.2 dB or < 2°
for –45 dB to –60 dB
< 0.3 dB or < 3°
for –60 dB to –75 dB
< 1 dB or < 6°
32 GHz to 40 GHz
for +15 dB to +5 dB
< 0.4 dB or < 4°
for +5 dB to –40 dB
< 0.2 dB or < 2°
for –40 dB to –55 dB
< 0.4 dB or < 4°
for –55 dB to –70 dB
< 1 dB or < 6°
40 GHz to 50 GHz
for +15 dB to +5 dB
< 0.4 dB or < 4°
for +5 dB to –35 dB
< 0.2 dB or < 2°
for –35 dB to –50 dB
< 0.4 dB or < 4°
for –50 dB to –65 dB
< 1 dB or < 6°
50 GHz to 67 GHz
for +15 dB to +5 dB
< 0.4 dB or < 4°
for +5 dB to –30 dB
< 0.2 dB or < 2°
for –30 dB to –45 dB
< 0.4 dB or < 4°
for –45 dB to –60 dB
< 1 dB or < 6°
Specifications are based on a matched DUT, a measurement bandwidth of 10 Hz and a nominal source power of –10 dBm.
Trace stability
Trace noise of S11 (RMS)
R&S®ZVA8
R&S®ZVA24
R&S®ZVA40
R&S®ZVA50
R&S®ZVA67
Temperature dependence
12
at 0 dBm source power, 0 dB reflection and 1 kHz measurement bandwidth
300 kHz to 8 GHz
< 0.004 dB, typ. 0.001 dB
700 MHz to 24 GHz
< 0.004 dB, typ. 0.001 dB
700 MHz to 24 GHz
< 0.004 dB, typ. 0.001 dB
24 GHz to 40 GHz
< 0.015 dB, typ. 0.004 dB
700 MHz to 24 GHz
< 0.004 dB, typ. 0.001 dB
24 GHz to 50 GHz
< 0.015 dB, typ. 0.004 dB
700 MHz to 24 GHz
< 0.004 dB, typ. 0.001 dB
24 GHz to 48 GHz
< 0.015 dB, typ. 0.004 dB
48 GHz to 67 GHz
< 0.03 dB, typ. 0.01 dB
at 0 dB transmission or reflection
up to 24 GHz
< 0.05 dB/K or < 0.4°/K
24 GHz to 67 GHz
< 0.1 dB/K or < 1°/K
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
Version 12.00, July 2014
Phase
Magnitude
1
0,1
10
1
0,1
0,01
0
100
Uncertainty / deg
Uncertainty / dB
10
-20
-40
-60
-80
0
-100
-20
-40
-60
-80
-100
Transmission coefficient / dB
Transmission coefficient / dB
Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ®ZVA8
in the frequency range 300 kHz to 50 MHz.
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
Transmission coefficient / dB
-100
0
-20
-40
-60
-80
-100
Transmission coefficient / dB
Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ®ZVA8
in the frequency range 50 MHz to 8 GHz.
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
13
Version 12.00, July 2014
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
0
-100
-20
-40
-60
-80
-100
Transmission coefficient / dB
Transmission coefficient / dB
Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ®ZVA24
in the frequency range 10 MHz to 700 MHz.
Phase
Magnitude
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
-100
Transmission coefficient / dB
0
-20
-40
-60
-80
Transmission coefficient / dB
Typical accuracy of transmission magnitude and transmission phase measurements of the R&S®ZVA24
in the frequency range 700 MHz to 24 GHz.
14
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
-100
Version 12.00, July 2014
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
0
-100
-20
-40
-60
-80
-100
Transmission coefficient / dB
Transmission coefficient / dB
Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ®ZVA40
in the frequency range 10 MHz to 700 MHz.
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
0
-100
-20
-40
-60
-80
-100
Transmission coefficient / dB
Transmission coefficient / dB
Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ®ZVA40
in the frequency range 700 MHz to 24 GHz.
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
Transmission coefficient / dB
-100
0
-20
-40
-60
-80
-100
Transmission coefficient / dB
Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ®ZVA40
in the frequency range 24 GHz to 40 GHz.
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
15
Version 12.00, July 2014
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
0
-100
-20
-40
-60
-80
-100
Transmission coefficient / dB
Transmission coefficient / dB
Typical accuracy of transmission magnitude and transmission phase measurements
of the R&S®ZVA50 and R&S®ZVA67 in the frequency range 10 MHz to 700 MHz.
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
0
-100
-20
-40
-60
-80
-100
Transmission coefficient / dB
Transmission coefficient / dB
Typical accuracy of transmission magnitude and transmission phase measurements
of the R&S®ZVA50 and R&S®ZVA67 in the frequency range 700 MHz to 24 GHz.
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
-100
Transmission coefficient / dB
0
-20
-40
-60
Transmission coefficient / dB
Typical accuracy of transmission magnitude and transmission phase measurements
of the R&S®ZVA50 and R&S®ZVA67 in the frequency range 24 GHz to 50 GHz.
16
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
-80
-100
Version 12.00, July 2014
Magnitude
Phase
100
Uncertainty / deg
Uncertainty / dB
10
1
0.1
10
1
0.1
0.01
0
-20
-40
-60
-80
Transmission coefficient / dB
-100
0
-20
-40
-60
-80
-100
Transmission coefficient / dB
Typical accuracy of transmission magnitude and transmission phase measurements
of the R&S®ZVA67 in the frequency range 50 GHz to 67 GHz.
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
17
Version 12.00, July 2014
Accuracy of reflection measurements
R&S®ZVA8
300 kHz to 1 MHz
1 MHz to 8 GHz
R&S®ZVA24
10 MHz to 50 MHz
50 MHz to 24 GHz
R&S®ZVA40
10 MHz to 50 MHz
50 MHz to 40 GHz
R&S®ZVA50
10 MHz to 50 MHz
50 MHz to 50 GHz
for +10 dB to –25 dB
for –25 dB to –35 dB
for +10 dB to +3 dB
for +3 dB to –15 dB
for –15 dB to –25 dB
for –25 dB to –35 dB
< 1 dB or < 6°
< 3 dB or < 20°
< 0.6 dB or < 4°
< 0.4 dB or < 3°
< 1 dB or < 6°
< 3 dB or < 20°
for +3 dB to –15 dB
for –15 dB to –25 dB
for +10 dB to +3 dB
for +3 dB to –15 dB
for –15 dB to –25 dB
for –25 dB to –35 dB
< 1 dB or < 6°
< 3 dB or < 20°
< 0.6 dB or < 4°
< 0.4 dB or < 3°
< 1 dB or < 6°
< 3 dB or < 20°
for +3 dB to –15 dB
for –15 dB to –25 dB
for +10 dB to +3 dB
for +3 dB to –15 dB
for –15 dB to –25 dB
for –25 dB to –35 dB
< 1 dB or < 6°
< 3 dB or < 20°
< 0.6 dB or < 4°
< 0.4 dB or < 3°
< 1 dB or < 6°
< 3 dB or < 20°
for +3 dB to –15 dB
for –15 dB to –25 dB
for +10 dB to +3 dB
for +3 dB to –15 dB
for –15 dB to –25 dB
for –25 dB to –35 dB
< 1 dB or < 6°
< 3 dB or < 20°
< 0.6 dB or < 4°
< 0.4 dB or < 3°
< 1 dB or < 6°
< 3 dB or < 20°
R&S®ZVA67
10 MHz to 50 MHz
for +3 dB to –15 dB
< 1 dB or < 6°
for –15 dB to –25 dB
< 3 dB or < 20°
50 MHz to 67 GHz
for +10 dB to +3 dB
< 0.6 dB or < 4°
for +3 dB to –15 dB
< 0.4 dB or < 3°
for –15 dB to –25 dB
< 1 dB or < 6°
for –25 dB to –35 dB
< 3 dB or < 20°
Specifications are based on an isolating DUT, a measurement bandwidth of 10 Hz and a nominal source power of –10 dBm.
Phase
0.05
Uncertainty / deg
Uncertainty (linear)
Magnitude
0.04
0.03
0.02
0.01
0.00
0
0.2
0.4
0.6
0.8
1
Reflection coefficient (linear)
10
8
6
4
2
0
0
0.2
0.4
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
0.8
Reflection coefficient (linear)
Typical accuracy of reflection magnitude and reflection phase measurements
of the R&S®ZVA8 in the frequency range 1 MHz to 8 GHz,
of the R&S®ZVA24 in the frequency range 50 MHz to 24 GHz,
of the R&S®ZVA40 in the frequency range 50 MHz to 40 GHz,
of the R&S®ZVA50 in the frequency range 50 MHz to 50 GHz
and of the R&S®ZVA67 in the frequency range 50 MHz to 67 GHz.
18
0.6
1
Version 12.00, July 2014
Effective system data
This data is valid between +18 °C and +28 °C, provided the temperature has not varied by more than 1 K after calibration. The data is
based on a measurement bandwidth of 10 Hz and system error calibration using the previously mentioned calibration kit. Frequency
points, measurement bandwidth and sweep time have to be identical for measurement and calibration (no interpolation allowed).
R&S®ZVA8 and R&S®ZV-Z270
Directivity
Source match
Reflection tracking
Load match
Transmission tracking
R&S®ZVA24 and R&S®ZV-Z235
Directivity
Source match
Reflection tracking
Load match
Transmission tracking
R&S®ZVA40 and R&S®ZV-Z229
Directivity
Source match
Reflection tracking
Load match
Transmission tracking
R&S®ZVA50 and R&S®ZV-Z224
Directivity
Source match
Reflection tracking
Load match
Transmission tracking
10 MHz to 700 MHz
700 MHz to 8 GHz
10 MHz to 700 MHz
700 MHz to 8 GHz
10 MHz to 700 MHz
700 MHz to 8 GHz
10 MHz to 700 MHz
700 MHz to 8 GHz
10 MHz to 700 MHz
700 MHz to 8 GHz
> 36 dB, typ. 46 dB
> 40 dB, typ. 46 dB
> 30 dB, typ. 43 dB
> 36 dB, typ. 43 dB
< 0.2 dB, typ. 0.04 dB
< 0.1 dB, typ. 0.02 dB
> 36 dB, typ. 46 dB
> 40 dB, typ. 46 dB
< 0.2 dB, typ. 0.04 dB
< 0.1 dB, typ. 0.02 dB
10 MHz to 700 MHz
700 MHz to 24 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
> 36 dB, typ. 46 dB
> 40 dB, typ. 46 dB
> 30 dB, typ. 43 dB
> 36 dB, typ. 43 dB
< 0.2 dB, typ. 0.04 dB
< 0.1 dB, typ. 0.02 dB
> 36 dB, typ. 46 dB
> 40 dB, typ. 46 dB
< 0.2 dB, typ. 0.04 dB
< 0.1 dB, typ. 0.02 dB
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 40 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 40 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 40 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 40 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 40 GHz
> 33 dB, typ. 36 dB
> 38 dB, typ. 42 dB
> 33 dB, typ. 36 dB
> 30 dB, typ. 36 dB
> 36 dB, typ. 40 dB
> 30 dB, typ. 36 dB
< 0.2 dB, typ. 0.1 dB
< 0.1 dB, typ. 0.05 dB
< 0.2 dB, typ. 0.1 dB
> 33 dB, typ. 36 dB
> 38 dB, typ. 42 dB
> 33 dB, typ. 36 dB
< 0.2 dB, typ. 0.1 dB
< 0.1 dB, typ. 0.04 dB
< 0.2 dB, typ. 0.08 dB
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 50 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 50 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 50 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 50 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 50 GHz
> 33 dB, typ. 40 dB
> 40 dB, typ. 46 dB
> 33 dB, typ. 36 dB
> 30 dB, typ. 40 dB
> 36 dB, typ. 40 dB
> 30 dB, typ. 36 dB
< 0.2 dB, typ. 0.1 dB
< 0.1 dB, typ. 0.05 dB
< 0.2 dB, typ. 0.1 dB
> 33 dB, typ. 40 dB
> 38 dB, typ. 42 dB
> 33 dB, typ. 36 dB
< 0.2 dB, typ. 0.1 dB
< 0.1 dB, typ. 0.05 dB
< 0.2 dB, typ. 0.1 dB
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
19
Version 12.00, July 2014
R&S®ZVA67 and R&S®ZV-Z218
Directivity
Source match
Reflection tracking
Load match
Transmission tracking
20
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 67 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 67 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 67 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 67 GHz
10 MHz to 700 MHz
700 MHz to 24 GHz
24 GHz to 67 GHz
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
> 30 dB, typ. 36 dB
> 36 dB, typ. 42 dB
> 32 dB, typ. 38 dB
> 30 dB, typ. 36 dB
> 36 dB, typ. 42 dB
> 30 dB, typ. 36 dB
< 0.2 dB, typ. 0.1 dB
< 0.1 dB, typ. 0.05 dB
< 0.2 dB, typ. 0.1 dB
> 30 dB, typ. 36 dB
> 36 dB, typ. 42 dB
> 30 dB, typ. 36 dB
< 0.2 dB, typ. 0.1 dB
< 0.1 dB, typ. 0.05 dB
< 0.2 dB, typ. 0.1 dB
Version 12.00, July 2014
Test port output
Power range
(without optional step attenuators
and without optional direct
generator/receiver access)
R&S®ZVA8
300 kHz to 50 MHz
–40 dBm to +10 dBm,
typ. –45 dBm to +14 dBm
–40 dBm to +13 dBm,
typ. –45 dBm to +15 dBm
–40 dBm to +10 dBm,
typ. –45 dBm to +13 dBm
–40 dBm to +8 dBm,
typ. –45 dBm to +12 dBm
50 MHz to 4 GHz
4 GHz to 7 GHz
7 GHz to 8 GHz
R&S®ZVA24
10 MHz to 13 GHz
–30 dBm to +13 dBm 3,
typ. –40 dBm to +18 dBm
–30 dBm to +10 dBm,
typ. –40 dBm to +16 dBm
13 GHz to 24 GHz
R&S®ZVA40
10 MHz to 50 MHz
–30 dBm to +10 dBm 4,
typ. –40 dBm to +15 dBm
–30 dBm to +13 dBm,
typ. –40 dBm to +18 dBm
–30 dBm to +10 dBm,
typ. –40 dBm to +15 dBm
–30 dBm to +9 dBm,
typ. –40 dBm to +12 dBm
50 MHz to 20 GHz
20 GHz to 32 GHz
32 GHz to 40 GHz
R&S®ZVA50
10 MHz to 50 MHz
–30 dBm to +10 dBm,
typ. –40 dBm to +15 dBm
–30 dBm to +13 dBm,
typ. –40 dBm to +18 dBm
–30 dBm to +12 dBm,
typ. –40 dBm to +15 dBm
–30 dBm to +10 dBm,
typ. –40 dBm to +12 dBm
50 MHz to 20 GHz
20 GHz to 35 GHz
35 GHz to 50 GHz
R&S®ZVA67
10 MHz to 50 MHz
–30 dBm to +10 dBm,
typ. –40 dBm to +15 dBm
–30 dBm to +13 dBm,
typ. –40 dBm to +18 dBm
–30 dBm to +10 dBm,
typ. –40 dBm to +15 dBm
–30 dBm to +8 dBm,
typ. –40 dBm to +12 dBm
–30 dBm to +5 dBm,
typ. –40 dBm to +6 dBm
–30 dBm to +4 dBm,
typ. –40 dBm to +6 dBm
–30 dBm to +2 dBm,
typ. –40 dBm to +6 dBm
typ. –30 dBm to +2 dBm
50 MHz to 20 GHz
20 GHz to 32 GHz
32 GHz to 50 GHz
50 GHz to 60 GHz
60 GHz to 64 GHz
64 GHz to 67 GHz
67 GHz to 70 GHz
3
R&S®ZVA24 with four ports, four sources: 10 MHz to 20 MHz: –30 dBm to +3 dBm.
4
R&S®ZVA40 with four ports, four sources: 10 MHz to 20 MHz: –30 dBm to +5 dBm.
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
21
Version 12.00, July 2014
Power accuracy
(with ALC on; without power calibration)
Power linearity
in temperature range +18 °C to +28 °C
(with ALC on; without power calibration)
Power resolution
Harmonics
(output power referenced to maximum
specified output power)
R&S®ZVA8 at –10 dBm
in temperature range +18 °C to +28 °C
50 MHz to 8 GHz
R&S®ZVA24 at –10 dBm
in temperature range +18 °C to +28 °C
500 MHz to 24 GHz
R&S®ZVA40 at –10 dBm
in temperature range +18 °C to +28 °C
500 MHz to 24 GHz
24 GHz to 40 GHz
R&S®ZVA50 at –10 dBm
in temperature range +18 °C to +28 °C
500 MHz to 24 GHz
24 GHz to 50 GHz
R&S®ZVA67 at –10 dBm
in temperature range +18 °C to +28 °C
500 MHz to 24 GHz
24 GHz to 67 GHz
referenced to –10 dBm
above 50 MHz
R&S®ZVA8 above 50 MHz
R&S®ZVA24 above 500 MHz
R&S®ZVA40 above 500 MHz
R&S®ZVA50 above 500 MHz
R&S®ZVA67 above 500 MHz
R&S®ZVA8
300 kHz to 50 MHz at –3 dB
50 MHz to 4 GHz at –5 dB
4 GHz to 7 GHz at –2 dB
7 GHz to 8 GHz at 0 dB
R&S®ZVA24
10 MHz to 50 MHz at –3 dB
50 MHz to 13 GHz at –3 dB
13 GHz to 24 GHz at 0 dB
R&S®ZVA40
10 MHz to 50 MHz at –3 dB
50 MHz to 20 GHz at –3 dB
20 GHz to 40 GHz at 0 dB
R&S®ZVA50
10 MHz to 50 MHz at –3 dB
50 MHz to 20 GHz at –3 dB
20 GHz to 50 GHz at –5 dB
R&S®ZVA67
10 MHz to 50 MHz at –3 dB
50 MHz to 5 GHz at –3 dB
5 GHz to 67 GHz at –3 dB
< 2 dB
< 0.8 dB, typ. 0.3 dB
< 3 dB
< 0.8 dB, typ. 0.3 dB
< 3 dB
< 0.8 dB, typ. 0.3 dB
< 2 dB, typ. 0.8 dB
< 3 dB
< 0.8 dB, typ. 0.3 dB
< 2 dB, typ. 0.8 dB
< 3 dB
< 0.8 dB, typ. 0.3 dB
< 2 dB, typ. 1 dB
< 2 dB
< 0.8 dB, typ. 0.3 dB
< 0.8 dB, typ. 0.3 dB
< 0.8 dB, typ. 0.3 dB
< 0.8 dB, typ. 0.3 dB
< 0.8 dB, typ. 0.3 dB
0.01 dB
typ. < –30 dBc
< –20 dBc, typ. < –30 dBc
< –20 dBc, typ. < –30 dBc
< –20 dBc, typ. < –30 dBc
typ. < –30 dBc
< –20 dBc, typ. < –30 dBc
< –20 dBc, typ. < –30 dBc
typ. < –30 dBc
< –20 dBc, typ. < –30 dBc
< –20 dBc, typ. < –30 dBc
typ. < –30 dBc
< –20 dBc, typ. < –30 dBc
< –20 dBc, typ. < –30 dBc
typ. < –20 dBc
< –15 dBc, typ. < –25 dBc
< –20 dBc, typ. < –30 dBc
Maximum output power in dBm versus frequency in GHz of the R&S®ZVA8.
22
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
Version 12.00, July 2014
Maximum output power in dBm versus frequency in GHz of the R&S®ZVA24.
Maximum output power in dBm versus frequency in GHz of the R&S®ZVA40.
Maximum output power in dBm versus frequency in GHz of the R&S®ZVA50.
Maximum output power in dBm versus frequency in GHz of the R&S®ZVA67.
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
23
Version 12.00, July 2014
Output power accuracy in dB versus frequency in GHz of the R&S ®ZVA8.
Output power accuracy in dB versus frequency in GHz of the R&S ®ZVA24.
Output power accuracy in dB versus frequency in GHz of the R&S ®ZVA40.
Output power accuracy in dB versus frequency in GHz of the R&S®ZVA50.
24
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
Version 12.00, July 2014
Output power accuracy in dB versus frequency in GHz of the R&S ®ZVA67.
Test port input
Match
Maximum nominal input level
without system error correction
R&S®ZVA8
300 kHz to 7 GHz
7 GHz to 8 GHz
R&S®ZVA24
10 MHz to 50 MHz
50 MHz to 2 GHz
2 GHz to 24 GHz
R&S®ZVA40
10 MHz to 4 GHz
4 GHz to 20 GHz
20 GHz to 40 GHz
R&S®ZVA50
10 MHz to 50 MHz
50 MHz to 10 GHz
10 GHz to 20 GHz
20 GHz to 40 GHz
40 GHz to 50 GHz
R&S®ZVA67
10 MHz to 50 MHz
50 MHz to 10 GHz
10 GHz to 20 GHz
20 GHz to 40 GHz
40 GHz to 67 GHz
R&S®ZVA8
300 kHz to 8 GHz
R&S®ZVA24
10 MHz to 13 GHz
13 GHz to 24 GHz
R&S®ZVA40
10 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 40 GHz
R&S®ZVA50
10 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 50 GHz
R&S®ZVA67
10 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 67 GHz
> 16 dB
> 14 dB
> 10 dB
> 12 dB
> 8 dB
> 12 dB
> 8 dB
> 6 dB
> 8 dB
> 10 dB
> 8 dB
> 6 dB
> 5 dB
> 8 dB
> 10 dB
> 9 dB
> 8 dB
> 6 dB
+13 dBm
+15 dBm
+10 dBm
+10 dBm
+6 dBm
+3 dBm
+10 dBm
+6 dBm
+3 dBm
+10 dBm
+6 dBm
+3 dBm
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
25
Version 12.00, July 2014
Power measurement accuracy
26
at –10 dBm without power calibration in temperature range +18 °C to +28 °C
R&S®ZVA8
10 MHz to 8 GHz
< 1 dB
R&S®ZVA24
10 MHz to 50 MHz
< 2 dB
10 MHz to 13 GHz
< 1 dB
13 GHz to 24 GHz
< 2 dB
R&S®ZVA40
10 MHz to 50 MHz
< 2 dB
50 MHz to 13 GHz
< 1 dB
13 GHz to 24 GHz
< 2 dB
24 GHz to 40 GHz
< 3 dB
R&S®ZVA50
10 MHz to 50 MHz
< 2 dB
50 MHz to 13 GHz
< 1 dB
13 GHz to 24 GHz
< 2 dB
24 GHz to 50 GHz
< 3 dB
R&S®ZVA67
10 MHz to 50 MHz
< 2 dB
50 MHz to 13 GHz
< 1 dB
13 GHz to 24 GHz
< 2 dB
24 GHz to 50 GHz
< 3 dB
50 GHz to 67 GHz
< 4 dB
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
Version 12.00, July 2014
Receiver linearity
Damage level
Damage DC voltage
referenced to –10 dBm in temperature range +18 °C to +28 °C
R&S®ZVA8
for +20 dB to –60 dB
50 MHz to 8 GHz
< 0.1 dB
for –60 dB to –85 dB
50 MHz to 8 GHz
typ. < 0.1 dB
R&S®ZVA24
for +20 dB to –30 dB
50 MHz to 700 MHz
< 0.1 dB
for –30 dB to –50 dB
50 MHz to 700 MHz
typ. < 0.1 dB
for +20 dB to +10 dB
700 MHz to 24 GHz
< 0.3 dB
for +10 dB to –45 dB
700 MHz to 24 GHz
< 0.1 dB
for –45 dB to –80 dB
700 MHz to 24 GHz
typ. < 0.1 dB
R&S®ZVA40
for +20 dB to –30 dB
50 MHz to 250 MHz
< 0.1 dB
for –30 dB to –50 dB
50 MHz to 250 MHz
typ. < 0.1 dB
for +10 dB to +5 dB
250 MHz to 40 GHz
< 0.3 dB
for +5 dB to –45 dB
250 MHz to 40 GHz
< 0.1 dB
for –45 dB to –65 dB
250 MHz to 40 GHz
typ. < 0.1 dB
R&S®ZVA50
for +20 dB to –30 dB
50 MHz to 250 MHz
< 0.1 dB
for –30 dB to –50 dB
50 MHz to 250 MHz
typ. < 0.1 dB
for +10 dB to +5 dB
250 MHz to 50 GHz
< 0.3 dB
for +5 dB to –45 dB
250 MHz to 50 GHz
< 0.1 dB
for –45 dB to –65 dB
250 MHz to 50 GHz
typ. < 0.1 dB
R&S®ZVA67
for +15 dB to –30 dB
50 MHz to 250 MHz
< 0.1 dB
for –30 dB to –50 dB
50 MHz to 250 MHz
typ. < 0.1 dB
for +10 dB to +5 dB
250 MHz to 67 GHz
< 0.3 dB
for +5 dB to –45 dB
250 MHz to 67 GHz
< 0.1 dB
for –45 dB to –60 dB
250 MHz to 67 GHz
typ. < 0.1 dB
+27 dBm
30 V
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
27
Version 12.00, July 2014
Noise level
(without optional step attenuators
and without optional direct
generator/receiver access)
at 10 Hz measurement bandwidth
R&S®ZVA8
300 kHz to 100 MHz
< –100 dBm
100 MHz to 8 GHz
< –115 dBm
R&S®ZVA24
10 MHz to 100 MHz
typ. < –80 dBm
100 MHz to 700 MHz
< –80 dBm
700 MHz to 2 GHz
< –110 dBm
2 GHz to 13 GHz
< –115 dBm
13 GHz to 24 GHz
< –110 dBm
R&S®ZVA40
10 MHz to 100 MHz
typ. < –80 dBm
100 MHz to 500 MHz
< –80 dBm
500 MHz to 2 GHz
< –110 dBm
2 GHz to 20 GHz
< –115 dBm
20 GHz to 24 GHz
< –110 dBm
24 GHz to 32 GHz
< –105 dBm
32 GHz to 40 GHz
< –100 dBm
R&S®ZVA50
10 MHz to 100 MHz
typ. < –80 dBm
100 MHz to 500 MHz
< –100 dBm
500 MHz to 24 GHz
< –115 dBm
24 GHz to 40 GHz
< –110 dBm
40 GHz to 50 GHz
< –100 dBm
R&S®ZVA67
10 MHz to 100 MHz
typ. < –80 dBm
100 MHz to 500 MHz
< –105 dBm
500 MHz to 2 GHz
< –110 dBm
2 GHz to 24 GHz
< –118 dBm
24 GHz to 40 GHz
< –105 dBm
40 GHz to 50 GHz
< –102 dBm
50 GHz to 67 GHz
< –100 dBm
Noise level at optional measurement input at 10 Hz measurement bandwidth
(direct generator/receiver access option)
R&S®ZVA8
100 MHz to 8 GHz
typ. < –130 dBm
R&S®ZVA24
100 MHz to 24 GHz
typ. < –130 dBm
R&S®ZVA40
100 MHz to 24 GHz
typ. < –130 dBm
24 GHz to 40 GHz
typ. < –120 dBm
R&S®ZVA50
100 MHz to 24 GHz
typ. < –130 dBm
24 GHz to 40 GHz
typ. < –120 dBm
40 GHz to 50 GHz
typ. < –115 dBm
R&S®ZVA67
100 MHz to 24 GHz
typ. < –130 dBm
24 GHz to 40 GHz
typ. < –120 dBm
40 GHz to 50 GHz
typ. < –115 dBm
50 GHz to 67 GHz
typ. < –110 dBm
The noise level is defined as the RMS value of the indicated noise floor. For the R&S®ZVA24 and R&S®ZVA40 with four ports, four
sources and the R&S®ZVA67 at single frequencies below 1.5 GHz, the noise level may be affected by spurious signals.
28
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
Version 12.00, July 2014
Additional front panel connectors
USB
(two) universal serial bus connectors for connecting USB devices (USB 2.0);
two additional USB connectors at the rear panel
Optional front panel connectors
SOURCE OUT
SOURCE IN
REF OUT
REF IN
MEAS OUT
MEAS IN
output of internal source signal
input for external source signal
output of internal reference signal
input for external reference signal
output of internal measurement signal
input for external measurement signal
Display
Screen
Resolution
26 cm (10.4") diagonal color LCD
800 × 600 × 262144 pixels (high color)
Rear panel connectors
IEC BUS
remote control in line with IEEE 488, IEC 60625; 24 pins
LAN 1
first local area network connector, 8 pins, 8P8C RJ-45 western modular jack
LAN 2
second local area network connector, 8 pins, 8P8C RJ-45 western modular jack
USB
(two) universal serial bus connectors for connecting USB devices (USB 2.0);
two additional USB connectors at the front panel
10 MHz REF
Connector type
Input frequency
Maximum permissible deviation
Input power
Input impedance
Output frequency
Output frequency accuracy
Output power
alternatively input or output for external frequency reference signal
BNC, female
10 MHz
1 kHz
–5 dBm to +10 dBm
50 Ω
10 MHz
80 Hz
–5 dBm to +10 dBm at 50 Ω
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
29
Version 12.00, July 2014
DC MEAS 1 V
Connector type
Voltage range
Measurement accuracy
Resolution
Bandwidth
Input impedance
Damage voltage
DC measurement input
DC MEAS 10 V
Connector type
Voltage range
Measurement accuracy
Resolution
Bandwidth
Input impedance
Damage voltage
DC measurement input
PORT BIAS
Connector type
Maximum nominal input voltage
Maximum nominal input current
Damage voltage
Damage current
DC bias input for PORT
MONITOR
IBM-PC-compatible VGA monitor connector, 15-pin D-Sub (for external monitor)
CASCADE
output for pulse and sync LVDS signals from internal pulse generator, for connection to
R&S®ZVAX CASCADE IN, 8P8C RJ-45 western modular jack
USER CONTROL
several control and trigger signals, 25-pin D-Sub, 3.3 V TTL
for controlling external generators, for limit checks, sweep signals, etc.
pin 24 and pin 25 (inputs)
control inputs
pin 16 to pin 19 (outputs)
indicate driving port
pin 8 to pin 11 (outputs)
channel-specific user-configurable bits
pin 13 and pin 14 (outputs)
pass/fail results of limit checks
pin 4 (output)
measurements running
pin 6 (output)
ready for trigger
pin 21 (output)
control signal for external generator
pin 22 (input)
handshake signal from external generator
pin 2 (input)
trigger input for analyzer
FOOT SWITCH 1 and FOOT SWITCH 2
DRIVE PORT 1 to DRIVE PORT 4
CHANNEL BIT 0 to CHANNEL BIT 3
PASS 1 and PASS 2
BUSY
READY FOR TRIGGER
EXT GEN TRIGGER
EXT GEN BLANK
EXTERNAL TRIGGER
EXT TRIGGER
Connector type
TTL signal (edge-triggered)
Polarity (user-selectable)
Minimum pulse width
Input impedance
30
4-pin mini DIN, female
–1 V to +1 V
2.5 % of reading + 2.5 mV
12 bit
<100 kHz
> 10 kΩ
30 V
4-pin mini DIN, female
–10 V to +10 V
2.5 % of reading + 25 mV
12 bit
<100 kHz
> 10 kΩ
30 V
BNC, female
30 V
200 mA
30 V
500 mA
trigger input for analyzer
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
BNC, female
3V
positive or negative
1 µs
> 10 kΩ
Version 12.00, July 2014
Options
Pulsed measurements
(R&S®ZVA-K7, R&S®ZVA-B7)
Recording time
Measurement bandwidths
Universal control interface I/O port
(R&S®ZVA-B14)
Agilent handler interface compatibility
Input signals
Output signals
Input/output signals
+5 V output
Response time of write strobe signal
Pulse width of write strobe signal
Pulse width of external trigger signal
Pulse width of sweep end signal
Direct generator/receiver access
(R&S®ZVA-B16)
Front panel connectors
Frequency range
Dynamic range
enlarged memory for increased number of pulse samples
with R&S®ZVA-K7 only
with R&S®ZVA-K7 and R&S®ZVA-B7
1/2/5 steps
 3 ms
 24 ms
1 Hz to 30 MHz
several control and trigger signals, 36-pin Centronics connector, 3.3 V TTL
for controlling external devices, limit checks, sweep signals, etc.
type 3
pin 2, pin 18
3.3 V TTL, 5 V tolerant
pin 3 to pin 17, pin 19 to pin 21,
3.3 V TTL, 5 V tolerant
pin 30 to pin 34, pin 36
pin 22 to pin 29
3.3 V TTL, 5 V tolerant
pin 35
+5 V, max. 100 mA
pin 32
1 µs
pin 32
1 µs
pin 18
> 1 µs
pin 34
> 10 µs
These options permit direct access to the internal source output as well as to the
internal reference and measurement receiver inputs via front panel connectors. If all
front panel jumper cables are directly connected between the outputs and inputs, the
following vector network analyzer specifications apply.
R&S®ZVA8
SMA, female
R&S®ZVA24
2.92 mm, female
R&S®ZVA40
2.92 mm, female
R&S®ZVA50
1.85 mm, female
R&S®ZVA67
1.85 mm, female
R&S®ZVA8
300 kHz to 8 GHz
R&S®ZVA24
10 MHz to 24 GHz
R&S®ZVA40
10 MHz to 40 GHz
R&S®ZVA50
10 MHz to 50 GHz
R&S®ZVA67
10 MHz to 67 GHz
R&S®ZVA8
300 kHz to 8 GHz
is reduced by 2 dB
R&S®ZVA24
10 MHz to 13 GHz
is reduced by 2 dB
13 GHz to 24 GHz
is reduced by 4 dB
R&S®ZVA40
10 MHz to 13 GHz
is reduced by 2 dB
13 GHz to 24 GHz
is reduced by 4 dB
24 GHz to 40 GHz
is reduced by 6 dB
R&S®ZVA50
10 MHz to 13 GHz
is reduced by 2 dB
13 GHz to 24 GHz
is reduced by 4 dB
24 GHz to 50 GHz
is reduced by 6 dB
R&S®ZVA67
10 MHz to 13 GHz
is reduced by 2 dB
13 GHz to 24 GHz
is reduced by 4 dB
24 GHz to 67 GHz
is reduced by 6 dB
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
31
Version 12.00, July 2014
Power range
Match
Noise level
32
R&S®ZVA8
300 kHz to 8 GHz
R&S®ZVA24
10 MHz to 13 GHz
13 GHz to 24 GHz
R&S®ZVA40
10 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 40 GHz
R&S®ZVA50
10 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 50 GHz
R&S®ZVA67
10 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 67 GHz
R&S®ZVA40
10 MHz to 4 GHz
R&S®ZVA8
300 kHz to 8 GHz
R&S®ZVA24
10 MHz to 13 GHz
13 GHz to 24 GHz
R&S®ZVA40
10 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 40 GHz
R&S®ZVA50
10 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 50 GHz
R&S®ZVA67
10 MHz to 13 GHz
13 GHz to 24 GHz
24 GHz to 67 GHz
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
upper limit is reduced by 1 dB
upper limit is reduced by 1 dB
upper limit is reduced by 2 dB
upper limit is reduced by 1 dB
upper limit is reduced by 2 dB
upper limit is reduced by 3 dB
upper limit is reduced by 1 dB
upper limit is reduced by 2 dB
upper limit is reduced by 3 dB
upper limit is reduced by 1 dB
upper limit is reduced by 2 dB
upper limit is reduced by 3 dB
is reduced by 2 dB
is increased by 1 dB
is increased by 1 dB
is increased by 2 dB
is increased by 1 dB
is increased by 2 dB
is increased by 3 dB
is increased by 1 dB
is increased by 2 dB
is increased by 3 dB
is increased by 1 dB
is increased by 2 dB
is increased by 3 dB
Version 12.00, July 2014
Generator step attenuators
(R&S®ZVA-B2x)
Frequency range
Power range
Power linearity
(with ALC off)
Dynamic range
R&S®ZVA8, R&S®ZVA24 and R&S®ZVA40:
Generator step attenuators extend the lower limit of the output power range by 70 dB.
R&S®ZVA50 and R&S®ZVA67:
Generator step attenuators extend the lower limit of the output power range by 50 dB.
R&S®ZVA8
300 kHz to 8 GHz
R&S®ZVA24
10 MHz to 24 GHz
R&S®ZVA40
10 MHz to 40 GHz
R&S®ZVA50
10 MHz to 50 GHz
R&S®ZVA67
10 MHz to 67 GHz
R&S®ZVA8
300 kHz to 8 GHz
upper limit is reduced by 1 dB
300 kHz to 8 GHz
lower limit is extended by 70 dB
R&S®ZVA24
10 MHz to 13 GHz
upper limit is reduced by 1 dB
13 GHz to 24 GHz
upper limit is reduced by 2 dB
10 MHz to 24 GHz
lower limit is extended by 70 dB
R&S®ZVA40
10 MHz to 13 GHz
upper limit is reduced by 1 dB
13 GHz to 24 GHz
upper limit is reduced by 2 dB
24 GHz to 40 GHz
upper limit is reduced by 3 dB
10 MHz to 40 GHz
lower limit is extended by 70 dB
R&S®ZVA50
10 MHz to 13 GHz
upper limit is reduced by 1 dB
13 GHz to 24 GHz
upper limit is reduced by 2 dB
24 GHz to 50 GHz
upper limit is reduced by 3 dB
10 MHz to 50 GHz
lower limit is extended by 50 dB
R&S®ZVA67
10 MHz to 13 GHz
upper limit is reduced by 1 dB
13 GHz to 24 GHz
upper limit is reduced by 2 dB
24 GHz to 67 GHz
upper limit is reduced by 3 dB
10 MHz to 67 GHz
lower limit is extended by 50 dB
R&S®ZVA8, R&S®ZVA24 and R&S®ZVA40
above –70 dBm
< 2 dB
from –70 dBm to –100 dBm
< 3 dB
R&S®ZVA50 and R&S®ZVA67
above –50 dBm
< 2 dB
from –50 dBm to –80 dBm
< 3 dB
R&S®ZVA8
300 kHz to 8 GHz
is reduced by 1 dB
R&S®ZVA24
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
R&S®ZVA40
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
24 GHz to 40 GHz
is reduced by 3 dB
R&S®ZVA50
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
24 GHz to 50 GHz
is reduced by 3 dB
R&S®ZVA67
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
24 GHz to 67 GHz
is reduced by 3 dB
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
33
Version 12.00, July 2014
Receiver step attenuators
(R&S®ZVA-B3x)
Frequency range
Attenuation
Attenuation steps
Attenuation accuracy
Dynamic range
Noise level
34
These attenuators permit the input signal level to be attenuated
in 5 dB steps up to 35 dB.
R&S®ZVA8
300 kHz to 8 GHz
R&S®ZVA24
10 MHz to 24 GHz
R&S®ZVA40
10 MHz to 40 GHz
R&S®ZVA50
10 MHz to 50 GHz
R&S®ZVA67
10 MHz to 67 GHz
0 dB to 35 dB
5 dB
< 2 dB
R&S®ZVA8
300 kHz to 8 GHz
is reduced by 1 dB
R&S®ZVA24
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
R&S®ZVA40
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
24 GHz to 40 GHz
is reduced by 3 dB
R&S®ZVA50
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
24 GHz to 50 GHz
is reduced by 3 dB
R&S®ZVA67
10 MHz to 13 GHz
is reduced by 1 dB
13 GHz to 24 GHz
is reduced by 2 dB
24 GHz to 67 GHz
is reduced by 3 dB
R&S®ZVA8
300 kHz to 8 GHz
is increased by 1 dB
R&S®ZVA24
10 MHz to 13 GHz
is increased by 1 dB
13 GHz to 24 GHz
is increased by 2 dB
R&S®ZVA40
10 MHz to 13 GHz
is increased by 1 dB
13 GHz to 24 GHz
is increased by 2 dB
24 GHz to 40 GHz
is increased by 3 dB
R&S®ZVA50
10 MHz to 13 GHz
is increased by 1 dB
13 GHz to 24 GHz
is increased by 2 dB
24 GHz to 50 GHz
is increased by 3 dB
R&S®ZVA67
10 MHz to 13 GHz
is increased by 1 dB
13 GHz to 24 GHz
is increased by 2 dB
24 GHz to 67 GHz
is increased by 3 dB
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
Version 12.00, July 2014
General data
Temperature loading
Damp heat
Mechanical resistance
Calibration interval
EMC, RF emission
EMC, immunity
Safety
Power supply
Power consumption
Test mark
Dimensions (W × H × D)
Weight
Shipping weight
in line with IEC 60068-2-1 and IEC 60068-2-2
operating temperature range
+5 °C to +40 °C
permissible temperature range
+5 °C to +40 °C
storage temperature range
–40 °C to +70 °C
+40 °C at 95 % rel. humidity,
in line with IEC 60068-2-30
vibration, sinusoidal
5 Hz to 150 Hz,
in line with IEC 60068-2-6
vibration, random
10 Hz to 300 Hz,
in line with IEC 60068-2-64
shock
40 g shock spectrum,
in line with IEC 60068-2-27, MIL-STD-810
1 year
in line with EN 55011 class A, operation in in line with CISPR 11/EN 55011 group 1
residential, commercial and business
class A (for a shielded test setup);
areas or in small-size companies is not
the instrument complies with the emission
covered; therefore the instrument may not requirements stipulated by EN 55011 and
be operated in residential, commercial and EN 61326-1 class A, making the
business areas or in small-size companies instrument suitable for use in industrial
unless additional measures are taken to
environments
ensure that EN 55011 class B is complied
with
in line with IEC/EN 61326-1,
immunity for industrial environments
(excluding operating frequency)
in line with IEC 61010-1, EN 61010-1 and
UL 3111-1
100 V to 240 V (AC) with tolerance ±10 %,
50 Hz to 60 Hz with tolerance ±5 %,
safety class I to VDE 411
R&S®ZVA8, R&S®ZVA24 (1 or 2 sources), 450 W, typ. 310 W (standby: typ. 10 W)
R&S®ZVA40 (1 or 2 sources) and
R&S®ZVA50
R&S®ZVA24 (4 sources),
650 W, typ. 450 W (standby: typ. 10 W)
R&S®ZVA40 (4 sources) and R&S®ZVA67
VDE, GS, CSA, CSA-NRTL/C,
CE conformity mark
465.1 mm × 286.2 mm × 495.0 mm
(18.31 in × 11.27 in × 19.49 in)
25 kg (55 lb)
37 kg (82 lb)
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
35
Version 12.00, July 2014
Ordering information
Designation
Vector Network Analyzer, 8 GHz, two ports
Vector Network Analyzer, 8 GHz, four ports
Vector Network Analyzer, 24 GHz, two ports
Vector Network Analyzer, 24 GHz, four ports, two sources
Vector Network Analyzer, 24 GHz, four ports, four sources
Upgrade Vector Network Analyzer, 24 GHz, four ports,
two sources  four sources
Vector Network Analyzer, 40 GHz, two ports, 2.92 mm
Vector Network Analyzer, 40 GHz, four ports, 2.92 mm,
two sources
Vector Network Analyzer, 40 GHz, four ports, 2.92 mm,
four sources
Upgrade Vector Network Analyzer, 40 GHz, four ports,
two sources  four sources
Vector Network Analyzer, 40 GHz, two ports, 2.4 mm
Vector Network Analyzer, 40 GHz, four ports, 2.4 mm
Vector Network Analyzer, 50 GHz, two ports
Vector Network Analyzer, 50 GHz, four ports
Vector Network Analyzer, 67 GHz, two ports
Vector Network Analyzer, 67 GHz, four ports
Options
Direct Generator/Receiver Access
for the R&S®ZVA8 with two ports
for the R&S®ZVA8 with four ports
for the R&S®ZVA24 with two ports
for the R&S®ZVA24 with four ports
for the R&S®ZVA40 with two ports
for the R&S®ZVA40 with four ports
for the R&S®ZVA50 with two ports
for the R&S®ZVA50 with four ports
for the R&S®ZVA67 with two ports
for the R&S®ZVA67 with four ports
Generator Step Attenuator Port 1
for the R&S®ZVA8
for the R&S®ZVA24
for the R&S®ZVA40
for the R&S®ZVA50
for the R&S®ZVA67
Generator Step Attenuator Port 2
for the R&S®ZVA8
for the R&S®ZVA24
for the R&S®ZVA40
for the R&S®ZVA50
for the R&S®ZVA67
Generator Step Attenuator Port 3
for the R&S®ZVA8 with four ports
for the R&S®ZVA24 with four ports
for the R&S®ZVA40 with four ports
for the R&S®ZVA50 with four ports
for the R&S®ZVA67 with four ports
Generator Step Attenuator Port 4
for the R&S®ZVA8 with four ports
for the R&S®ZVA24 with four ports
for the R&S®ZVA40 with four ports
for the R&S®ZVA50 with four ports
for the R&S®ZVA67 with four ports
36
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
Type
R&S®ZVA8
R&S®ZVA8
R&S®ZVA24
R&S®ZVA24
R&S®ZVA24
R&S®ZVA24-U5
Order No.
1145.1110.08
1145.1110.10
1145.1110.24
1145.1110.26
1145.1110.28
1312.7710.28
R&S®ZVA40
R&S®ZVA40
1145.1110.40
1145.1110.42
R&S®ZVA40
1145.1110.48
R&S®ZVA40-U5
1312.7710.48
R&S®ZVA40
R&S®ZVA40
R&S®ZVA50
R&S®ZVA50
R&S®ZVA67
R&S®ZVA67
1145.1110.43
1145.1110.45
1145.1110.50
1145.1110.52
1305.7002.02
1305.7002.04
R&S®ZVA8-B16
R&S®ZVA8-B16
R&S®ZVA24-B16
R&S®ZVA24-B16
R&S®ZVA40-B16
R&S®ZVA40-B16
R&S®ZVA50-B16
R&S®ZVA50-B16
R&S®ZVA67-B16
R&S®ZVA67-B16
1164.0209.08
1164.0209.10
1164.0209.24
1164.0209.26
1164.0209.40
1164.0209.42
1164.0209.50
1164.0209.52
1164.0209.67
1164.0209.69
R&S®ZVA8-B21
R&S®ZVA24-B21
R&S®ZVA40-B21
R&S®ZVA50-B21
R&S®ZVA67-B21
1164.0009.02
1164.0109.02
1302.5409.02
1305.5616.02
1305.7077.02
R&S®ZVA8-B22
R&S®ZVA24-B22
R&S®ZVA40-B22
R&S®ZVA50-B22
R&S®ZVA67-B22
1164.0015.02
1164.0115.02
1302.5415.02
1305.5622.02
1305.7083.02
R&S®ZVA8-B23
R&S®ZVA24-B23
R&S®ZVA40-B23
R&S®ZVA50-B23
R&S®ZVA67-B23
1164.0021.02
1164.0121.02
1302.5421.02
1305.5639.02
1305.7090.02
R&S®ZVA8-B24
R&S®ZVA24-B24
R&S®ZVA40-B24
R&S®ZVA50-B24
R&S®ZVA67-B24
1164.0038.02
1164.0138.02
1302.5438.02
1305.5645.02
1305.7102.02
Version 12.00, July 2014
Receiver Step Attenuator Port 1
for the R&S®ZVA8
for the R&S®ZVA24
for the R&S®ZVA40
for the R&S®ZVA50
for the R&S®ZVA67
Receiver Step Attenuator Port 2
for the R&S®ZVA8
for the R&S®ZVA24
for the R&S®ZVA40
for the R&S®ZVA50
for the R&S®ZVA67
Receiver Step Attenuator Port 3
for the R&S®ZVA8 with four ports
for the R&S®ZVA24 with four ports
for the R&S®ZVA40 with four ports
for the R&S®ZVA50 with four ports
for the R&S®ZVA67 with four ports
Receiver Step Attenuator Port 4
for the R&S®ZVA8 with four ports
for the R&S®ZVA24 with four ports
for the R&S®ZVA40 with four ports
for the R&S®ZVA50 with four ports
for the R&S®ZVA67 with four ports
Oven Quartz (OCXO)
External Attenuator Control for R&S®ZVA-Z90E/-Z110E
Cable Set for R&S®ZVA-K9 (using R&S®ZVA8)
Cable Set for R&S®ZVA-K9
(using R&S®ZVA24 or R&S®ZVA40 with 2.92 mm)
Cable Set for R&S®ZVA-K9
(using R&S®ZVA40 with 2.4 mm, R&S®ZVA50 or R&S®ZVA67)
Universal Control Interface I/O Port
Removable Flash Disc 4 Gbyte (for R&S®FMR6/5)
Removable Flash Disc 4 Gbyte (for R&S®FMR7/3, R&S FMR7/6)
Removable Hard Disc 160 Gbyte
(for R&S®FMR7/3, R&S FMR7/6)
Additional Removable Flash Disc 4 Gbyte (for R&S®FMR6/5)
Additional Removable Flash Disc 4 Gbyte
(for R&S®FMR7/3, R&S®FMR7/6)
Additional Removable Hard Disc 160 Gbyte
(for R&S®FMR7/3, R&S®FMR7/6)
Time Domain
Frequency Conversion
Mixer Phase Measurement
True Differential Mode
Pulsed Measurements
Pulsed Measurements
Pulsed Measurements with increased recording time
for two-port models
Pulsed Measurements with increased recording time
for four-port models
Converter Control Software
Mixer Delay without LO Access
Long Distance Mixer Delay
5 MHz Receiver Bandwidth
Internal Pulse Generators
Noise Figure Measurements
R&S®ZVA8-B31
R&S®ZVA24-B31
R&S®ZVA40-B31
R&S®ZVA50-B31
R&S®ZVA67-B31
1164.0044.02
1164.0144.02
1302.5444.02
1305.5716.02
1305.7119.02
R&S®ZVA8-B32
R&S®ZVA24-B32
R&S®ZVA40-B32
R&S®ZVA50-B32
R&S®ZVA67-B32
1164.0050.02
1164.0150.02
1302.5450.02
1305.5722.02
1305.7125.02
R&S®ZVA8-B33
R&S®ZVA24-B33
R&S®ZVA40-B33
R&S®ZVA50-B33
R&S®ZVA67-B33
1164.0067.02
1164.0167.02
1302.5467.02
1305.5739.02
1305.7131.02
R&S®ZVA8-B34
R&S®ZVA24-B34
R&S®ZVA40-B34
R&S®ZVA50-B34
R&S®ZVA67-B34
R&S®ZVAB-B4
R&S®ZVA-B8
R&S®ZVA-B9
R&S®ZVA-B9
1164.0073.02
1164.0173.02
1302.5473.02
1305.5745.02
1305.7148.02
1164.1757.02
1307.6026.02
1305.6541.02
1305.6541.03
R&S®ZVA-B9
1305.6541.04
R&S®ZVAB-B14
R&S®ZVAB-B18
R&S®ZVAB-B18
R&S®ZVAB-B18
1305.6306.02
1164.0715.02
1164.0715.03
1164.0715.04
R&S®ZVAB-B19
R&S®ZVAB-B19
1164.1111.02
1164.1111.03
R&S®ZVAB-B19
1164.1111.04
R&S®ZVAB-K2
R&S®ZVA-K4
R&S®ZVA-K5
R&S®ZVA-K6
1164.1657.02
1164.1863.02
1311.3134.02
1164.1540.02
R&S®ZVA-K7
R&S®ZVA-B7
1164.1511.02
1164.1492.02
R&S®ZVA-B7
1164.1492.03
R&S®ZVA-K8
R&S®ZVA-K9
R&S®ZVA-K10
R&S®ZVA-K17
R&S®ZVA-K27
R&S®ZVA-K30
1307.7022.02
1311.3128.02
1164.1805.02
1164.1070.02
1164.1892.02
1164.1828.02
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
37
Version 12.00, July 2014
Service options
Extended Warranty, one year
Extended Warranty, two years
Extended Warranty, three years
Extended Warranty, four years
Extended Warranty with Calibration Coverage, one year
Extended Warranty with Calibration Coverage, two years
Extended Warranty with Calibration Coverage, three years
Extended Warranty with Calibration Coverage, four years
R&S®WE1
R&S®WE2
R&S®WE3
R&S®WE4
R&S®CW1
R&S®CW2
R&S®CW3
R&S®CW4
Please contact your local
Rohde & Schwarz sales office.
Extended warranty with a term of one to four years (WE1 to WE4)
Repairs carried out during the contract term are free of charge 5. Necessary calibration and adjustments carried out during repairs are
also covered. Simply contact the forwarding agent we name; your product will be picked up free of charge and returned to you in top
condition a couple of days later.
Extended warranty with calibration (CW1 to CW4)
Enhance your extended warranty by adding calibration coverage at a package price. This package ensures that your
Rohde & Schwarz product is regularly calibrated, inspected and maintained during the term of the contract. It includes all repairs 5 and
calibration at the recommended intervals as well as any calibration carried out during repairs or option upgrades.
For product brochure, see PD 5213.5680.12 and www.rohde-schwarz.com
5
Excluding defects caused by incorrect operation or handling and force majeure. Wear-and-tear parts are not included.
38
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
Version 12.00, July 2014
Rohde & Schwarz R&S®ZVA Vector Network Analyzer
39
Service that adds value
Worldwide
Local and personalized
❙ Customized and flexible
❙ Uncompromising quality
❙ Long-term dependability
❙
❙
About Rohde & Schwarz
The Rohde & Schwarz electronics group is a leading
­supplier of solutions in the fields of test and measurement,
broadcasting, secure communications, and radiomonitor­
ing and radiolocation. Founded more than 80 years ago,
this independent global company has an extensive sales
network and is present in more than 70 countries.
The company is headquartered in Munich, Germany.
Sustainable product design
❙❙ Environmental compatibility and eco-footprint
❙❙ Energy efficiency and low emissions
❙❙ Longevity and optimized total cost of ownership
Certified Quality Management
ISO 9001
Certified Environmental Management
ISO 14001
Rohde & Schwarz GmbH & Co. KG
www.rohde-schwarz.com
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG
Trade names are trademarks of the owners
PD 5213.5680.22 | Version 12.00 | July 2014 (as)
R&S®ZVA Vector Network Analyzer
Data without tolerance limits is not binding | Subject to change
© 2005 - 2014 Rohde & Schwarz GmbH & Co. KG | 81671 Munich, Germany
5213.5680.22 12.00 PDP 1 en
Regional contact
❙❙ Europe, Africa, Middle East | +49 89 4129 12345
[email protected]
❙❙ North America | 1 888 TEST RSA (1 888 837 87 72)
[email protected]
❙❙ Latin America | +1 410 910 79 88
[email protected]
❙❙ Asia/Pacific | +65 65 13 04 88
[email protected]
❙❙ China | +86 800 810 8228/+86 400 650 5896
[email protected]
5213568022
ZVA_dat-sw_en_5213-5680-22_cover.indd 2
02.07.2014 10:22:26