PUME - Installation Manual(TN1PUME-E)

PUME - Installation Manual(TN1PUME-E)
90% RH or below (with no condensation)
Vibration
10 to 70Hz less than 9.8m/s² (1G)
Warm-up time
30 min. or more
Installation category
IEC1010-1: class II
Pollution level
IEC1010-1: degree 2
2-4
• Note that the insulation class for this equipment is as follows. Before installing,
please confirm that the insulation class for equipment meets usage requirements.
Power
Loader communication
RS-485 communication
- The alarm function does not work properly when an error occurs unless the settings
are made correctly. Always verify its setting before operation.
DI1-4
2-5
DI5-8
DO1-4
Others
- Please do not wipe the equipment with organic solvents such as alcohol or benzene,
etc. If wiping is necessary, use a neutral cleaning agent.
- Do not use mobile phones near this equipment (within 50cm). Otherwise a
malfunction may result.
- Malfunctions may occur if the equipment is used near a radio, TV, or wireless device.
- This equipment requires approx. 20 seconds before it starts to output.
- Before installing and wiring, take necessary measures for electrostatic discharge
(ESD).
DO5-8
Functional insulation (1000Vac)
Functional insulation (500Vac)
F012
50
100
6.1
-
COM
RS-485 receiving
-
RS-485 transmitting
Di1- 8
Digital inputting
Do1- 8
Digital outputting
Terminal
Screw size M3
(30)
(8)
ORANGE
Error
5
RED
RUN
DIN rail
Terminal
Screw size M3
When locking tab is released
(when mounting /
dismounting to / from DIN rails)
Main unit
(when detached from the base part)
[mm]
Cautions when mounting
In order to aid heat dissipation, 30mm of clearance (50mm recommended) above and
under the controllers should be provided.
- Actions to be displayed for COM, Di1-8 and Do1-8 can be allocated by programming.
30 or more
- Base part
Mounting screw hole
Module connector
(Connect controllers
laterally)
Module connector
Power terminal block
See [Wiring]
Mounting screw hole
See [Mounting]
30 or more
RS-485 terminal block
See [Wiring]
Locking tab
[mm]
- Mounting to DIN rails
Setting
- Setting Station No.
Set Station No. of each controller before mounting.
Apply a fine tip flat-head screwdriver to turn the Station No. configuration switch.
Rotary SW setting
Station No.
0
17
1
18
2
19
3
20
4
21
5
22
6
23
7
24
8
25
9
26
A
27
B
28
C
29
D
30
E
31
F
32
Hook the back
of controller
1. Pull down the locking tab of the
base part. Hook the back of the
controller onto the upper part of
DIN rail.
2. Push the controller in the
direction of arrow 2.
DIN rail
Locking tab
PWR
COM
PUM-E
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
3. Push up the locking tab to fasten
the controller onto DIN rail.
4. When connecting controllers
after mounting to DIN rail, push
up the locking tab after doing so.
LOADER
STATION
345
Station No.
setting switch
- Attaching end plates
- Each of connected controllers must have a different Station No. from other
controllers. Duplicate Station No. may cause malfunction of the equipment.
When mounting controllers to DIN rails, we recommend to attach side connecting
terminal covers (right and left 1set), then end plates (optional) to the ends of the
rightmost and leftmost controllers.
DIN rail mounting
end plate
PWR
PUM-A
PWR
LOADER
COM
COM
OUT1
OUT2
OUT3
345
PUM-E
PWR
LOADER
COM
STATION
2
3456
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
PUM-E
PWR
LOADER
COM
STATION
2
3456
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
PUM-E
PWR
LOADER
COM
STATION
2
3456
Side connecting terminal cover
(right & left 1 set)
-1-
-2-
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
PUM-E
LOADER
STATION
2
3456
789
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
789
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
789
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
789
7 8 9A
OUT4
STATION
6
- In cases where damage or problems with this equipment may lead to serious
accidents, install appropriate external protective circuits.
- To prevent damage and failure of the equipment, provide the rated power voltage.
- To prevent electric shock and equipment failure, do not turn the power ON until all
wiring is complete.
- Before turning the power ON, confirm that clearance space has been secured to
prevent shock or fire.
- Do not touch the terminal while the machine is ON. Doing so risks shock or
equipment errors.
- Never disassemble, convert, modify or repair this equipment. Doing so risks abnormal
operation, shock or fire.
E
GREEN
PWR
Cautions for Wiring
Error Operation
6
F01
Ambient humidity
LED
789A
-10 to 50 degree C
LED indicator
LED lamps indicate the following operational conditions.
6
Ambient temperature
1.5
F01
• This equipment is intended to be used under the following conditions.
STATION
OUT4
F01
Installation and Wiring
LOADER
COM
OUT3
F01
1-1
Warning
Base part
(when detached from
the main unit)
85
PUM-A
PWR
OUT2
F012
1
(10)
E
Warning
Improper use of the equipment may cause injury to the user or property
damage.
30
F012
Improper use of the equipment may result in death or serious injuries.
Station No.
Configuration switch
See [Setting]
E
Caution
345
OUT1
Cautions when Mounting to Cabinets / DIN rails
- Input signal wire and output signal wire should be separated from each other. And
both should be shielded.
- If the output operation frequency is high, selecting a SSR/SSC drive output type is
recommended.
[Proportionate cycles] Relay output: 30 sec. or more, SSR/SSC drive output: 1sec.
or more
- When inductive loads such as magnetic opening/closing equipment, etc. as relay
output equipment are connected, use of "Z-trap," manufactured by Fuji Electric
Device Technology Co., Ltd., is recommended in order to protect the contacts against
opening/closing surges and to ensure long-term use.
21
11
Model names
: ENE241D-07A
22
12
(For 100V power voltage)
23
13
: ENE471D-07A
24
14
(For 200V power voltage)
25
15
Attachment position : Please connect between the
26
16
relay control output contacts.
27
17
- To comply with CE marking (EMC), we recommend to
28
18
attach ferrite core to communication cable and power
cable.
29
19
- For wiring to the terminal block, apply crimp type
30
20
terminals size M3.
Z-trap connecting diagram
Screw size
: M3 x 7 (with square washer)
Screw tightening torque: 0.78N-m (8kgf-cm)
- To avoid the influence of inductive noise, input signal wires should be separated from
electric power lines or load lines.
Please read this section thoroughly before using and observe the mentioned safety
warnings fully.
Safety warnings are categorized as "Warning" or "Caution".
Terminal block
(when detached from the main unit)
STATION
BCD
2-3
Loader communication port
BCDE
Please Read First (Safety Warnings)
LOADER
Input/output
terminals
See [Wiring]
- In case of mounting the temperature controllers to DIN rails, remember to push up
the locking tabs to fasten the controllers onto DIN rail.
- To connect controllers, first release all locking tabs. Then, connect controllers and
push up all locking tabs. Make sure that all locking tabs are fastened.
- Never fail to turn the power OFF, before detaching the terminal block or removing the
main unit from the base part.
- In order to aid heat dissipation, do not block the top and the bottom of the equipment.
- When mounting / dismounting controllers to / from DIN rails, 30mm of clearance
above and under the controllers should be provided.
INPTN5A0201-E
Front screw terminal cover
(optional)
PUM-E
A
2-2
ECNO 1162
INPTN5A0199-E
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
BCDE
Material No.
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
A
Material
name
Specification Catalog
Operating
Event Input
instruction
/ Output
module
User's
manual
Tool
PUM
parameter
loader
Cautions when Installing
COM
BCDE
Related Information
Refer to "Module Type Temperature
Controller Event Input/Output Module
User's Manual" for details about the
items described in this manual.
Content
2-1
PWR
LED indicator
A
The contents of this manual are subject to change without notice.
This manual is complied with possible care for the purpose of accuracy, however,
Fuji Electric Systems shall not be held liable for any damages, including indirect
damage, caused by typographical errors,
absence of information or use of information in this manual.
Temperature Controller Event input/
output Module
1 Unit
Instruction Manual 1 Copy
Caution
Please avoid installing in the following locations.
- Locations in which the ambient temperature falls outside the range of 0 to 50 degrees
C when equipment is in use.
- Locations in which the ambient humidity falls outside the range of 45 to 85% RH
when equipment is in use.
- Locations with rapid temperature changes, leading to dew condensation.
- Locations with corrosive gases (especially sulfide gas, ammonia, etc.) or flammable
gases.
- Locations with vibration or shock directly.
- Locations in contact with water, oil, chemicals, steam or hot water.
(If the equipment gets wet, there is a risk of electric shock or fire, so have it
inspected by Fuji distributor.)
- Locations with high concentrations of atmospheric dust, salt or iron particles.
- Locations with large inductive interference, resulting in static electricity, magnetic
fields or noise.
- Locations in direct sunlight.
- Locations that build up heat from radiant heat sources, etc.
CAUTION
Confirming Specifications and Accessories
2
- Dimensions
DIO indicator
BCDE
Thank you for purchasing the Fuji module type temperature controller.
Once you have confirmed that this is the product you ordered, please use it in
accordance with the following instructions.
For detailed information on operating this equipment, please refer to the separate
user's manual.
In addition, please keep this instruction manual within easy reach of the actual person
using this equipment.
- Event input/output module controller
7 8 9A
INP-TN1PUME-E
Mounting
6
Model : PUME
Part names and functions
A
Event Input/Output Module
Before using the product, confirm that it
matches the type ordered.
(For model code, please refer to page 4.)
Confirm that all of the following
accessories are included.
Maintenance
- When installing or removing the equipment, turn the power OFF. Otherwise, shock,
operational errors or failures may be caused.
- Periodic maintenance is recommended for continuous and safe use of this
equipment.
- Some parts installed on this equipment have a limited life and/or may deteriorate with
age.
- The warranty period for this unit (including accessories) is one year, if the product is
used properly.
BCD
1-2
Multi-loop module type Temperature Controller
BCD
Instruction Manual (Installation)
DIN rail mounting
end plate
90% RH or below (with no condensation)
Vibration
10 to 70Hz less than 9.8m/s² (1G)
Warm-up time
30 min. or more
Installation category
IEC1010-1: class II
Pollution level
IEC1010-1: degree 2
2-4
• Note that the insulation class for this equipment is as follows. Before installing,
please confirm that the insulation class for equipment meets usage requirements.
Power
Loader communication
RS-485 communication
- The alarm function does not work properly when an error occurs unless the settings
are made correctly. Always verify its setting before operation.
DI1-4
2-5
DI5-8
DO1-4
Others
- Please do not wipe the equipment with organic solvents such as alcohol or benzene,
etc. If wiping is necessary, use a neutral cleaning agent.
- Do not use mobile phones near this equipment (within 50cm). Otherwise a
malfunction may result.
- Malfunctions may occur if the equipment is used near a radio, TV, or wireless device.
- This equipment requires approx. 20 seconds before it starts to output.
- Before installing and wiring, take necessary measures for electrostatic discharge
(ESD).
DO5-8
Functional insulation (1000Vac)
Functional insulation (500Vac)
F012
50
100
6.1
-
COM
RS-485 receiving
-
RS-485 transmitting
Di1- 8
Digital inputting
Do1- 8
Digital outputting
Terminal
Screw size M3
(30)
(8)
ORANGE
Error
5
RED
RUN
DIN rail
Terminal
Screw size M3
When locking tab is released
(when mounting /
dismounting to / from DIN rails)
Main unit
(when detached from the base part)
[mm]
Cautions when mounting
In order to aid heat dissipation, 30mm of clearance (50mm recommended) above and
under the controllers should be provided.
- Actions to be displayed for COM, Di1-8 and Do1-8 can be allocated by programming.
30 or more
- Base part
Mounting screw hole
Module connector
(Connect controllers
laterally)
Module connector
Power terminal block
See [Wiring]
Mounting screw hole
See [Mounting]
30 or more
RS-485 terminal block
See [Wiring]
Locking tab
[mm]
- Mounting to DIN rails
Setting
- Setting Station No.
Set Station No. of each controller before mounting.
Apply a fine tip flat-head screwdriver to turn the Station No. configuration switch.
Rotary SW setting
Station No.
0
17
1
18
2
19
3
20
4
21
5
22
6
23
7
24
8
25
9
26
A
27
B
28
C
29
D
30
E
31
F
32
Hook the back
of controller
1. Pull down the locking tab of the
base part. Hook the back of the
controller onto the upper part of
DIN rail.
2. Push the controller in the
direction of arrow 2.
DIN rail
Locking tab
PWR
COM
PUM-E
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
3. Push up the locking tab to fasten
the controller onto DIN rail.
4. When connecting controllers
after mounting to DIN rail, push
up the locking tab after doing so.
LOADER
STATION
345
Station No.
setting switch
- Attaching end plates
- Each of connected controllers must have a different Station No. from other
controllers. Duplicate Station No. may cause malfunction of the equipment.
When mounting controllers to DIN rails, we recommend to attach side connecting
terminal covers (right and left 1set), then end plates (optional) to the ends of the
rightmost and leftmost controllers.
DIN rail mounting
end plate
PWR
PUM-A
PWR
LOADER
COM
COM
OUT1
OUT2
OUT3
345
PUM-E
PWR
LOADER
COM
STATION
2
3456
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
PUM-E
PWR
LOADER
COM
STATION
2
3456
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
PUM-E
PWR
LOADER
COM
STATION
2
3456
Side connecting terminal cover
(right & left 1 set)
-1-
-2-
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
PUM-E
LOADER
STATION
2
3456
789
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
789
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
789
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
789
7 8 9A
OUT4
STATION
6
- In cases where damage or problems with this equipment may lead to serious
accidents, install appropriate external protective circuits.
- To prevent damage and failure of the equipment, provide the rated power voltage.
- To prevent electric shock and equipment failure, do not turn the power ON until all
wiring is complete.
- Before turning the power ON, confirm that clearance space has been secured to
prevent shock or fire.
- Do not touch the terminal while the machine is ON. Doing so risks shock or
equipment errors.
- Never disassemble, convert, modify or repair this equipment. Doing so risks abnormal
operation, shock or fire.
E
GREEN
PWR
Cautions for Wiring
Error Operation
6
F01
Ambient humidity
LED
789A
-10 to 50 degree C
LED indicator
LED lamps indicate the following operational conditions.
6
Ambient temperature
1.5
F01
• This equipment is intended to be used under the following conditions.
STATION
OUT4
F01
Installation and Wiring
LOADER
COM
OUT3
F01
1-1
Warning
Base part
(when detached from
the main unit)
85
PUM-A
PWR
OUT2
F012
1
(10)
E
Warning
Improper use of the equipment may cause injury to the user or property
damage.
30
F012
Improper use of the equipment may result in death or serious injuries.
Station No.
Configuration switch
See [Setting]
E
Caution
345
OUT1
Cautions when Mounting to Cabinets / DIN rails
- Input signal wire and output signal wire should be separated from each other. And
both should be shielded.
- If the output operation frequency is high, selecting a SSR/SSC drive output type is
recommended.
[Proportionate cycles] Relay output: 30 sec. or more, SSR/SSC drive output: 1sec.
or more
- When inductive loads such as magnetic opening/closing equipment, etc. as relay
output equipment are connected, use of "Z-trap," manufactured by Fuji Electric
Device Technology Co., Ltd., is recommended in order to protect the contacts against
opening/closing surges and to ensure long-term use.
21
11
Model names
: ENE241D-07A
22
12
(For 100V power voltage)
23
13
: ENE471D-07A
24
14
(For 200V power voltage)
25
15
Attachment position : Please connect between the
26
16
relay control output contacts.
27
17
- To comply with CE marking (EMC), we recommend to
28
18
attach ferrite core to communication cable and power
cable.
29
19
- For wiring to the terminal block, apply crimp type
30
20
terminals size M3.
Z-trap connecting diagram
Screw size
: M3 x 7 (with square washer)
Screw tightening torque: 0.78N-m (8kgf-cm)
- To avoid the influence of inductive noise, input signal wires should be separated from
electric power lines or load lines.
Please read this section thoroughly before using and observe the mentioned safety
warnings fully.
Safety warnings are categorized as "Warning" or "Caution".
Terminal block
(when detached from the main unit)
STATION
BCD
2-3
Loader communication port
BCDE
Please Read First (Safety Warnings)
LOADER
Input/output
terminals
See [Wiring]
- In case of mounting the temperature controllers to DIN rails, remember to push up
the locking tabs to fasten the controllers onto DIN rail.
- To connect controllers, first release all locking tabs. Then, connect controllers and
push up all locking tabs. Make sure that all locking tabs are fastened.
- Never fail to turn the power OFF, before detaching the terminal block or removing the
main unit from the base part.
- In order to aid heat dissipation, do not block the top and the bottom of the equipment.
- When mounting / dismounting controllers to / from DIN rails, 30mm of clearance
above and under the controllers should be provided.
INPTN5A0201-E
Front screw terminal cover
(optional)
PUM-E
A
2-2
ECNO 1162
INPTN5A0199-E
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
BCDE
Material No.
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
A
Material
name
Specification Catalog
Operating
Event Input
instruction
/ Output
module
User's
manual
Tool
PUM
parameter
loader
Cautions when Installing
COM
BCDE
Related Information
Refer to "Module Type Temperature
Controller Event Input/Output Module
User's Manual" for details about the
items described in this manual.
Content
2-1
PWR
LED indicator
A
The contents of this manual are subject to change without notice.
This manual is complied with possible care for the purpose of accuracy, however,
Fuji Electric Systems shall not be held liable for any damages, including indirect
damage, caused by typographical errors,
absence of information or use of information in this manual.
Temperature Controller Event input/
output Module
1 Unit
Instruction Manual 1 Copy
Caution
Please avoid installing in the following locations.
- Locations in which the ambient temperature falls outside the range of 0 to 50 degrees
C when equipment is in use.
- Locations in which the ambient humidity falls outside the range of 45 to 85% RH
when equipment is in use.
- Locations with rapid temperature changes, leading to dew condensation.
- Locations with corrosive gases (especially sulfide gas, ammonia, etc.) or flammable
gases.
- Locations with vibration or shock directly.
- Locations in contact with water, oil, chemicals, steam or hot water.
(If the equipment gets wet, there is a risk of electric shock or fire, so have it
inspected by Fuji distributor.)
- Locations with high concentrations of atmospheric dust, salt or iron particles.
- Locations with large inductive interference, resulting in static electricity, magnetic
fields or noise.
- Locations in direct sunlight.
- Locations that build up heat from radiant heat sources, etc.
CAUTION
Confirming Specifications and Accessories
2
- Dimensions
DIO indicator
BCDE
Thank you for purchasing the Fuji module type temperature controller.
Once you have confirmed that this is the product you ordered, please use it in
accordance with the following instructions.
For detailed information on operating this equipment, please refer to the separate
user's manual.
In addition, please keep this instruction manual within easy reach of the actual person
using this equipment.
- Event input/output module controller
7 8 9A
INP-TN1PUME-E
Mounting
6
Model : PUME
Part names and functions
A
Event Input/Output Module
Before using the product, confirm that it
matches the type ordered.
(For model code, please refer to page 4.)
Confirm that all of the following
accessories are included.
Maintenance
- When installing or removing the equipment, turn the power OFF. Otherwise, shock,
operational errors or failures may be caused.
- Periodic maintenance is recommended for continuous and safe use of this
equipment.
- Some parts installed on this equipment have a limited life and/or may deteriorate with
age.
- The warranty period for this unit (including accessories) is one year, if the product is
used properly.
BCD
1-2
Multi-loop module type Temperature Controller
BCD
Instruction Manual (Installation)
DIN rail mounting
end plate
- Fixing with screws
Wiring
When mounting controllers inside a cabinet with screws, connect the base parts of
controllers first.
- Fixing screws are not included. Please prepare screws as required.
1. Refer to the figure below for the mounting screw hole
(30)
size to decide the mounting position.
2-M3
- Front terminal block
OUT2
Do1
11
L
13
Do2
22
12
L
14
Do3
23
13
L
15
Do4
24
14
25
15
26
16
27
17
28
18
29
19
Transisitor
open collector
(sink) output
L
L
18
Do6
L
19
Do7
20
Di4
E
Di2
STATION
2
3456
789
F012
345
BCD
Di1
Di8
Di7
Side
connector
Di6
Locking tab
Di5
345
15
OUT2
OUT4
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
Do6
Do7
Do8
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
16
17
18
STATION
21
11
22
12
25
23
13
24
14
25
15
26
16
27
17
28
18
29
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
19
30
20
28
LOADER
DC 24V
29
STATION
345
BCD
- Base part (power terminal, RS-485 terminal)
4. All connected controllers are connected
to power supply and RS-485 via side
connectors if one of controllers is directly
connected to them.
Power terminal
5
6
7
8
9 10
Y Y 1 - 0
Description
Module type
Event input/output module
[Di 8 points/Do 8 points]
Output type (Event input/output module)
Open collector output
Relay contact output
Instruction manual
Japanese
English
Accessories (optional)
1
2
3
4
5
6
7
8
A
A
A
A
L
0
0
0
0
0
1
2
3
4
1
P U M Z *
Description
RS-485 terminating resistance
DIN rail mounting end plate
Side connecting terminal cover (right & left 1 set)
Front face screw terminal cover
Loader connecting cable (RS-232C)
Communication function
30
PUM-E
4
A
B
Digital output
20
LOADER
24
27
3
C
R
No. of output
: 8 points (4 points / common x 2 blocks)
Output type, rating
: Select from a) and b) according to the model specification
a) Relay contact output
- Contact structure : SPST contact
- Contact capacity : 220Vac / 30Vdc, 1A
b) Transistor open collector (sink output)
- Rating
: 24Vdc, 100mA (residual voltage when ON : 1.5Vdc or less)
23
26
2
E
19
PUM-E
345
1
P U M
No. of input
: 8 points (4 points / common × 2 blocks)
Input type
: Voltage contact input, sink / source common (bidirectional)
Input rating
: 24Vdc, Input impedance approx.4.7k ohm
Input judgment
: ON judgment
: 16 to 26.4Vdc
: OFF judgment
: 0 to 5Vdc
Input read cycle (min. pulse width):200ms
7 8 9A
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
F012
COM
STATION
Ambient humidity
6
F012
PWR
LOADER
7 8 9A
E
PUM-E
6
345
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
E
STATION
7 8 9A
OUT4
6
OUT3
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
F012
COM
E
PWR
LOADER
BCD
PUM-A
COM
OUT2
BCD
PWR
OUT1
OUT1
OUT3
22
DC 24V
RS-485 terminal
RS-485 interface
Communication standard
: RS-485
No. of ports
: 1 port
Communication, synchro method : Two-wire, half-duplex, asynchronous cycle
Communication speed
: 9.6k, 19.2k, 38.4k, 115.2kbps
Data form
: data bit ; 8, parity ; even / odd / none
Communication distance
: 1km (38.4kbps or less), 250m (115.2kbps)
Connectable units
: 33 units (both master and slave units included)
(32 units if any modules other than PUM series is included in slaves)
Protocol
: Modbus RTU compatible
Loader (RS-232C) interface
Communication standard
: RS-232C
No. of ports
: 1 port
Communication, synchro method : Half-duplex, asynchronous cycle
Communication speed
: 19.2 kbps (fixed)
Data form
: data bit 8, no parity
Protocol
: Modbus RTU compatible
Crimp terminal size
B (-)
A (+)
*All connected controllers are connected to power supply and RS-485 via side connectors
if one of controllers is directly connected to them.
How to detach the base part
1. Press the lock lever on the top of the
main unit.
Cable type
Size
Thermocouple (Compensation lead wire)
Power supply
1.25mm2 or less
1.25mm2 or less
Crimp terminal
Cable size
Screw tightening torque
0.25 to 1.25mm2
0.8Nm
6.0mm or less
Lock lever
Please prepare power cables and crimp terminals of the size indicated below.
Power cable
2. Pull down the upper part of main unit.
3. Detach the cutout on the lower end of
back of main unit from the projection
on the base part.
3.2mm
Ring crimp terminal
3.2mm
DC 24V (-)
DC 24V (+)
SG
6.0mm or less
3. After mounting controllers onto DIN rail,
make sure to push up all locking tabs.
Controllers are fastened to DIN rail and to
each other.
14
LOADER
F01
STATION
8 9A
67
OUT4
PUM-E
BCDE
OUT2
OUT3
2. Connect controllers with each other using
side connectors.
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
21
A
OUT1
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
13
7 8 9A
COM
12
6
Di3
PWR
LOADER
Do5
Do8
COM
PUM-A
COM
Do5
17
11
Event Input/Output module
: 24Vdc±10%
: Maximum 3.2W (135mA) [when 24Vdc is applied]
: 30(W)×100(H)×85(D) mm (excluding terminal cover and projection)
: Approx. 200g
: DIN rail mounting or mounting with M3 screws inside a cabinet
: -10 to 50 degrees C
* "Ambient temperature" is the temperature underneath the controller
inside the equipment or the cabinet where the controller is installed.
:90% RH or less (non condensing)
Digital input
Relay
contact
output
16 COM
PWR
COM
Do4
Power Supply
Power Consumption
Dimensions
Weight
Installation method
Ambient temperature*
20
- Connecting controllers
PWR
Do3
F012
30
Do2
DC 24V
L
1. Check that locking tabs are pulled down
(released).
COM
Do1
E
(100)
88.5 ±0.2
(3)
4. Fixate the base parts onto the mounting position inside the cabinet with screws.
5. Attach the main unit to the base parts.
12
BCD
3. Connect base parts. Push up to fasten all the locking tabs.
L
21
+0.2
30+0.7
[mm]
11 COM
STATION
345
Relay
contact
output
DC 24V
7 8 9A
OUT4
Transisitor
open collector
(sink) output
LOADER
Model code
General Specification
6
OUT3
PUM-E
F012
OUT1
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
E
COM
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
BCD
PWR
9±0.2
2. Remove the main unit from the base part.
See [How to detach the base part]
Specification
Y crimp terminal
- When attaching the main unit to the
base part, take the reverse procedure
to removing the main unit from the
base part.
- Make sure that the lock lever of the
main unit is fitted into the base part.
Projection
Main unit
Head Office
Gate City Osaki East Tower 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fesys.co.jp/eng
-3-
-4-
- Fixing with screws
Wiring
When mounting controllers inside a cabinet with screws, connect the base parts of
controllers first.
- Fixing screws are not included. Please prepare screws as required.
1. Refer to the figure below for the mounting screw hole
(30)
size to decide the mounting position.
2-M3
- Front terminal block
OUT2
Do1
11
L
13
Do2
22
12
L
14
Do3
23
13
L
15
Do4
24
14
25
15
26
16
27
17
28
18
29
19
Transisitor
open collector
(sink) output
L
L
18
Do6
L
19
Do7
20
Di4
E
Di2
STATION
2
3456
789
F012
345
BCD
Di1
Di8
Di7
Side
connector
Di6
Locking tab
Di5
345
15
OUT2
OUT4
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
Do6
Do7
Do8
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
16
17
18
STATION
21
11
22
12
25
23
13
24
14
25
15
26
16
27
17
28
18
29
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
19
30
20
28
LOADER
DC 24V
29
STATION
345
BCD
- Base part (power terminal, RS-485 terminal)
4. All connected controllers are connected
to power supply and RS-485 via side
connectors if one of controllers is directly
connected to them.
Power terminal
5
6
7
8
9 10
Y Y 1 - 0
Description
Module type
Event input/output module
[Di 8 points/Do 8 points]
Output type (Event input/output module)
Open collector output
Relay contact output
Instruction manual
Japanese
English
Accessories (optional)
1
2
3
4
5
6
7
8
A
A
A
A
L
0
0
0
0
0
1
2
3
4
1
P U M Z *
Description
RS-485 terminating resistance
DIN rail mounting end plate
Side connecting terminal cover (right & left 1 set)
Front face screw terminal cover
Loader connecting cable (RS-232C)
Communication function
30
PUM-E
4
A
B
Digital output
20
LOADER
24
27
3
C
R
No. of output
: 8 points (4 points / common x 2 blocks)
Output type, rating
: Select from a) and b) according to the model specification
a) Relay contact output
- Contact structure : SPST contact
- Contact capacity : 220Vac / 30Vdc, 1A
b) Transistor open collector (sink output)
- Rating
: 24Vdc, 100mA (residual voltage when ON : 1.5Vdc or less)
23
26
2
E
19
PUM-E
345
1
P U M
No. of input
: 8 points (4 points / common × 2 blocks)
Input type
: Voltage contact input, sink / source common (bidirectional)
Input rating
: 24Vdc, Input impedance approx.4.7k ohm
Input judgment
: ON judgment
: 16 to 26.4Vdc
: OFF judgment
: 0 to 5Vdc
Input read cycle (min. pulse width):200ms
7 8 9A
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
F012
COM
STATION
Ambient humidity
6
F012
PWR
LOADER
7 8 9A
E
PUM-E
6
345
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
E
STATION
7 8 9A
OUT4
6
OUT3
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
F012
COM
E
PWR
LOADER
BCD
PUM-A
COM
OUT2
BCD
PWR
OUT1
OUT1
OUT3
22
DC 24V
RS-485 terminal
RS-485 interface
Communication standard
: RS-485
No. of ports
: 1 port
Communication, synchro method : Two-wire, half-duplex, asynchronous cycle
Communication speed
: 9.6k, 19.2k, 38.4k, 115.2kbps
Data form
: data bit ; 8, parity ; even / odd / none
Communication distance
: 1km (38.4kbps or less), 250m (115.2kbps)
Connectable units
: 33 units (both master and slave units included)
(32 units if any modules other than PUM series is included in slaves)
Protocol
: Modbus RTU compatible
Loader (RS-232C) interface
Communication standard
: RS-232C
No. of ports
: 1 port
Communication, synchro method : Half-duplex, asynchronous cycle
Communication speed
: 19.2 kbps (fixed)
Data form
: data bit 8, no parity
Protocol
: Modbus RTU compatible
Crimp terminal size
B (-)
A (+)
*All connected controllers are connected to power supply and RS-485 via side connectors
if one of controllers is directly connected to them.
How to detach the base part
1. Press the lock lever on the top of the
main unit.
Cable type
Size
Thermocouple (Compensation lead wire)
Power supply
1.25mm2 or less
1.25mm2 or less
Crimp terminal
Cable size
Screw tightening torque
0.25 to 1.25mm2
0.8Nm
6.0mm or less
Lock lever
Please prepare power cables and crimp terminals of the size indicated below.
Power cable
2. Pull down the upper part of main unit.
3. Detach the cutout on the lower end of
back of main unit from the projection
on the base part.
3.2mm
Ring crimp terminal
3.2mm
DC 24V (-)
DC 24V (+)
SG
6.0mm or less
3. After mounting controllers onto DIN rail,
make sure to push up all locking tabs.
Controllers are fastened to DIN rail and to
each other.
14
LOADER
F01
STATION
8 9A
67
OUT4
PUM-E
BCDE
OUT2
OUT3
2. Connect controllers with each other using
side connectors.
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
21
A
OUT1
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
13
7 8 9A
COM
12
6
Di3
PWR
LOADER
Do5
Do8
COM
PUM-A
COM
Do5
17
11
Event Input/Output module
: 24Vdc±10%
: Maximum 3.2W (135mA) [when 24Vdc is applied]
: 30(W)×100(H)×85(D) mm (excluding terminal cover and projection)
: Approx. 200g
: DIN rail mounting or mounting with M3 screws inside a cabinet
: -10 to 50 degrees C
* "Ambient temperature" is the temperature underneath the controller
inside the equipment or the cabinet where the controller is installed.
:90% RH or less (non condensing)
Digital input
Relay
contact
output
16 COM
PWR
COM
Do4
Power Supply
Power Consumption
Dimensions
Weight
Installation method
Ambient temperature*
20
- Connecting controllers
PWR
Do3
F012
30
Do2
DC 24V
L
1. Check that locking tabs are pulled down
(released).
COM
Do1
E
(100)
88.5 ±0.2
(3)
4. Fixate the base parts onto the mounting position inside the cabinet with screws.
5. Attach the main unit to the base parts.
12
BCD
3. Connect base parts. Push up to fasten all the locking tabs.
L
21
+0.2
30+0.7
[mm]
11 COM
STATION
345
Relay
contact
output
DC 24V
7 8 9A
OUT4
Transisitor
open collector
(sink) output
LOADER
Model code
General Specification
6
OUT3
PUM-E
F012
OUT1
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
E
COM
Di1
Di2
Di3
Di4
Di5
Di6
Di7
Di8
BCD
PWR
9±0.2
2. Remove the main unit from the base part.
See [How to detach the base part]
Specification
Y crimp terminal
- When attaching the main unit to the
base part, take the reverse procedure
to removing the main unit from the
base part.
- Make sure that the lock lever of the
main unit is fitted into the base part.
Projection
Main unit
Head Office
Gate City Osaki East Tower 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fesys.co.jp/eng
-3-
-4-