Contents

Safety information

Unpacking and preparation

Installation and start-up

Control panel

Menu setting

Maintenance

Technical information

Cause and solution of problems

Channel functions

Congratulations on choosing a Clay Paky product!

We thank you for your custom.

Please note that this product, as all the others in the rich Clay

Paky range, has been designed and made with total quality to ensure excellent performance and best meet your expectations and requirements.

Carefully read this instruction manual in its entirety and keep it safe for future reference. It is essential to know the information and comply with the instructions given in this manual to ensure the fitting is installed, used and serviced correctly and safely.

CLAY PAKY S.p.A. disclaims all liability for damage to the fitting or to other property or persons deriving from installation, use and maintenance that have not been carried out in conformity with this instruction manual, which must always accompany the fitting.

CLAY PAKY S.p.A. reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice.

1

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 2

ALPHA WASH 700

700W

3

IP20

Pb

SAFETY INFORMATION

• Installation

Make sure all parts for fixing the projector are in a good state of repair.

Make sure the point of anchorage is stable before positioning the projector.

The safety chain must be properly hooked onto the fitting and secured to the framework, so that, if the primary support system fails, the fitting falls as little as possible.

If the safety chain gets used, it needs to be replaced with a genuine spare.

• Minimum distance of illuminated objects

The projector needs to be positioned so that the objects hit by the beam of light are at least 3 metres

(9’ 10”) from the lens of the projector.

• Minimum distance from flammable materials

The projector must be positioned so that any flammable materials are at least 0.20 metres (8") from every point on the surface of the fitting.

• Mounting surfaces

It is permissible to mount the fitting on normally flammable surfaces.

• Maximum ambient temperature

Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).

• IP20 protection rating

The fitting is protected against penetration by solid bodies of over 12mm (0.47”) in diameter (first digit 2), but not against dripping water, rain, splashes or jets of water (second digit 0).

• Protection against electrical shock

Connection must be made to a power supply system fitted with efficient earthing (

Class I

appliance according to standard EN 60598-1).

It is, moreover, recommended to protect the supply lines of the projectors from indirect contact and/or shorting to earth by using appropriately sized residual current devices.

• Connection to mains supply

Connection to the electricity mains must be carried out by a qualified electrical installer.

Check that the mains frequency and voltage correspond to those for which the projector is designed as given on the electrical data label.

This label also gives the input power to which you need to refer to evaluate the maximum number of fittings to connect to the electricity line, in order to avoid overloading.

• Temperature of the external surface

The maximum temperature that can be reached on the external surface of the fitting, in a thermally steady state, is 150°C (302°F).

• Maintenance

Before starting any maintenance work or cleaning the projector, cut off power from the mains supply.

After switching off, do not remove any parts of the fitting for at least 10 minutes. After this time the likelihood of the lamp exploding is virtually nill. If it is necessary to replace the lamp, wait for another

20 minutes to avoid getting burnt.

The fitting is designed to hold in any splinters produced by a lamp exploding. The lenses must be mounted and, if visibly damaged, they have to be replaced with genuine spares.

• Lamp

The fitting mounts a high-pressure lamp that needs an external igniter. This igniter is fitted onto the apparatus.

- Carefully read the "operating instructions" provided by the lamp manufacturer.

- Immediately replace the lamp if damaged or deformed by heat.

• Battery

This product contains a rechargeable lead-acid battery. To preserve the environment, please dispose the battery at the end of its life according to the regulation in force. Instructions on how to remove the battery from the product are available on

www.claypaky.it

The products referred to in this manual conform to the European Community Directives to which they are subject:

Low Voltage 2006/95/CE

Electromagnetic Compatibility 2004/108/CE

2

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 3

UNPACKING AND PREPARATION

1

099100

2 x 183102/802

Lamp 700W

(fitted into projector)

Packing contents

- Fig. 1

2

LOCKED

UNLOCKED

3

45° 45°

90°

90

°

°

90

90°

PAN Mechanism Lock and Release (every 90°)

- Fig. 2

TILT Mechanism Lock and Release (every 45°)

- Fig. 3

ALPHA WASH 700

3

LOCKED

UNLOCKED

5° 5°

4 4

° °

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 4

INSTALLATION AND START-UP

4

Installing the projector

- Fig. 4

The projector can be installed on the floor resting on special rubber feet, on a truss or on the ceiling or wall.

WARNING: with the exception of when the projector is positioned on the floor, the safety cable must be fitted. (Cod. 105041/003 available on request).

This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base.

5

2

1

2

1

3

Connecting and disconnecting power cable

- Fig. 5

ALPHA WASH 700

4

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 5

CONTROL PANEL

6

Mains

L

N

Connecting to the mains supply

- Fig. 6

7

DMX 512

5 PIN

5

4

3

1

2

SCREEN

SIGNAL

SIGNAL

DMX 512

5

DMX 512

3 PIN

2

3

1

SCREEN

Connecting to the control signal line (DMX)

- Fig. 7

Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 120Ohm characteristic impedance, 22-24 AWG, low capacity. Do not use microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 3 or 5-pin male/female connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.

IMPORTANT:

The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the shield braid and to pin 1 of the connectors.

8

Fixture ID

2

Dmx Address

1

Warning Message

SIGNAL

SIGNAL

Switching on the projector

- Fig. 8

Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:

Model Firmware xxx (Fixture ID) System errors

Alpha WASH Version X.X.X Dmx Address xxx E: .........................

700 Date - Hour W: .........................

On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the “Home” position (Pan 50% - Tilt 50%). The control panel

(Fig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two conditions: rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address and the Fixture ID address (if set).

During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.

It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the

F key will be cancelled.

Continue

5

ALPHA WASH 700

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 6

9

28

28

Reversal of the display

- Fig. 9

To activate this function, press UP

B and DOWN

C keys simultaneously while the display is in the rest mode. This status will be memorised and maintained even for the next time it will be switched on. To return to the initial state, repeat the operation all over again.

Setting the projector starting address

On each projector, the starting address must be set for the control signal (addresses from 1 to 512).

The address can also be set with the projector switched off.

Setting the address: see pag. 8.

Setting the projector Fixture ID

On each projector, the Fixture ID address must be set for an easy identification of the fixtures in an installation (ID from 1 to 255).

The Fixture ID address can be set with the projector switched off.

Setting the Fixture ID: see pag. 8.

Functions of the buttons - Using the menu

F

C

DOWN

B

UP

D

LEFT

E

RIGHT

Confirms the displayed value, or activates the displayed function, or enters the successive menu.

Decreases the value displayed (with auto-repetitions) or passes to the next item in the menu.

Increases the value displayed (with auto-repetitions) or passes to the previous item in a menu.

Return to the top level

Commute from units, tens, hundreds, in the "Address", "Fixture ID" and "Calibration" menù.

USING THE MENU:

1) Press

F once – “Main Menu” appears on the display.

2) Use the UP

B and DOWN

C keys to select the menu to be used:

• Setup (Setup Menu): To set the setting options.

• Option (Option Menu): To set the operating options

• Informations (Informations Menu): To read the counters, software version and other information.

• Manual Control (Manual control Menu): To trigger the test and manual control functions.

• Test (Test Menu): To check the proper functionning of effects

• Advanced (Advanced Menu): Access to the "Advanced menu" is recommended for a trained technical personnel.

To enable the "Advanced" see pag.13

3) Press

F to display the first item in the selected menu.

4) Use the UP

B and DOWN

C keys to select the MENU items.

Setting addresses and options with the projector disconnected

The projector’s DMX address, as well as other possible operating options, can also be set when the appliance is disconnected from the electricity supply.

All that is needed is to press

F to momentarily activate the display and thus access the settings. Once the required operations have been carried out, the display will switch off again after a wait time of 30 seconds.

ALPHA WASH 700

6

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 7

1

4

Option

Information

Manual

Control

Test

Advanced

Set Up

Dmx

Address

Channel

Mode

Fixture ID

Ethernet

Interface

Manual

Control

Lamp

Reset

Channel

ALPHA WASH 700

MENU SETTING

MAIN MENU

2

Option Lamp Dmx

Pan / Tilt

Color

Shutter

Power Mode

Shutter

On Error

Dimmer On

Shutter

4-700W

Full fan speed

400W

Low fan speed

4-700W

Auto fan speed

Invert

Pan

Invert

Tilt

Swap

Pan-Tilt

Encoder

Pan-Tilt

Color

Mixing

Color mixing curve

Fixed Wheel

Shortcut

Display

Setting

Default

Preset

User

Preset 1

User

Preset 2

User

Preset 3

3

Information

5

Test Pan / Tilt

Colour

Beam

All

7

System

Version

Board

Diagnost.

Dmx

Monitor

Fans

Monitor

Network params

System

Errors

Fixture

Hours

Lamp

Hours

Lamp

Strikes

6

Advanced

Access code

1234

Upload

Firmware

Setup

Model

Calibration

Continue

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 8

NOTE: On grey the default options

Set Up

Dmx

Address

Address xxx

ALPHA WASH 700

Channel

Mode

Standard

Vector

Fixture ID Value xxx

Ethernet

Interface

Control

Protocol

Repeat on

DMX

Universe

8

SET UP MENU

DMX ADDRESS

NOTE: without the DMX signal the Address (XXX) flashing

Allows you to select the DMX ADDRESS.

1) Press

F

- the current DMX Adress appear on the display.

2) Use the UP

B and DOWN

C

, RIGHT

E keys to plan the DMX

Address.

3) Press

F to confirm the selection or LEFT

D to keep current settings.

CHANNEL MODE

Allows you to select a channel arrangement from the two available.

1) Press

F

- the current settings appear on the display (Standard or

Vector).

2) Use the UP

B and DOWN

C keys to select one of the following settings:

- Standard

- Vector

3) Press

F to confirm the selection or LEFT

D to keep current settings.

FIXTURE ID

Allows you to select the FIXTURE ID.

1) Press

F

- the current Fixture ID appear on the display.

2) Use the UP

B

, DOWN

C

, RIGHT

E keys to plan the Fixture ID.

3) Press

F to confirm the selection or LEFT

D to keep current settings.

ETHERNET INTERFACE

It lets you set the Ethernet settings to be attributed to the projector.

1) Premere

F

.

2) Use the UP

B and DOWN

C keys to select the “Ethernet Interface” options to set:

Control Protocol

It lets you select the “Control Protocol” Art-net to assign according to the control unit used:

1) Press

F the current setting appears on the display.

2) Use the UP

B and DOWN

C keys to select one of the following settings:

- Disabled

- Art-net on IP 2

- Art-net on IP 10

3) Press

F to confirm the selection or LEFT

D to keep the current setting.

Repeat on DMX

It lets you enable the transmission of the Ethernet protocol by DMX signal to all the connected projectors.

1) Press

F the current setting appears on the display.

2) Use the UP

B and DOWN

C keys to select one of the following settings:

-

Disabled:

DMX transmission disabled.

-

Enabled on primary:

DMX transmission enabled.

3) Press

F to confirm the selection or LEFT

D to keep the current setting.

Universe

It lets you assign the “Universe” number to be assigned to a series of projectors.

1) Press

F

– the current Universe address appears on the display.

2) Use the UP

B

, DOWN

C

, RIGHT

E keys to set the Universe address.

3) Press

F to confirm the selection or LEFT

D to keep the current setting.

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 9

Option Lamp Dmx

On

Off

Pan / Tilt

Invert

Pan

On

Off

ALPHA WASH 700

Invert

Tilt

On

Off

Swap

Pan-Tilt

On

Off

Encoder

Pan-Tilt

On

Off

Color

Color

Mixing

Rgb

Cmy

Color

Mixing curve

Curve 1

Curve 2

Fixwheel

Shortcut

On

Off

OPTIONS MENU

LAMP DMX

Used for enabling lamp remote control channel.

1) Press

F

- the current settings appear on the display (On or Off).

2) Use the UP

B and DOWN

C keys to enable (On) or disable (Off) the lamp remote control channel.

3) Press

F to confirm the selection or LEFT

D to keep current settings.

PAN / TILT

Invert pan

Used for reversing Pan movement.

1) Press

F

- the current settings appear on the display (On or Off).

2) Use the UP

B and DOWN

C keys to enable (On) or disable (Off)

PAN inversion.

3) Press

F to confirm the selection or LEFT

D to keep current settings.

Invert tilt

Used for reversing tilt movement.

1) Press

F

- the current settings appear on the display (On or Off).

2) Use the UP

Tilt inversion.

B and DOWN

C keys to enable (On) or disable (Off)

3) Press

F to confirm the selection or LEFT

D to keep current settings.

Swap Pan-Tilt

Used for swapping Pan and Tilt channels (as well as Pan fine and Tilt fine).

1) Press

F

- the current settings appear on the display (On or Off).

2) Use the UP

B and DOWN

C keys to enable (On) or disable (Off)

Pan and Tilt channel swap.

3) Press

F to confirm the selection or LEFT

D to keep current settings.

Encoder Pan-Tilt

Used for enabling the Pan / Tilt encoders.

1) Press

F

- the current settings appear on the display (On or Off).

2) Use the UP

B and DOWN

C keys to enable (On) or disable (Off)

Pan / Tilt encoders.

3) Press

F to confirm the selection or LEFT

D to keep current settings.

COLOR

Color mixing

Used for reversing the CMY color mixing system.

1) Press

F

- the current settings appear on the display (On or Off).

2) Use the UP

B and DOWN

C keys select one of the following settings:

RGB color mixing mode

CMY color mixing mode

3) Press

F to confirm the selection or LEFT

D to keep current settings.

Color mixing curve

It lets you select the “Color mixing curve” from the two available.

1) Press

F the current setting appears on the display.

2) Use the UP

B and DOWN

C keys to select one of the following settings:

Curve 1

Curve 2

3) Press

F to confirm the selection or LEFT

D to keep the current setting.

9

Fixed wheel short-cut

Used for optimizing color change time so that the disc turns in the direction that requires shorter movement.

1) Press

F

– the current settings appear on the display (On or Off).

2) Use the UP

B and DOWN

C keys to enable (On) or disable (Off) color change optimization.

3) Press

F to confirm the selection, or LEFT

D to keep current settings.

Continue

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 10

Shutter

Shutter

On Error

On

Off

Dimmer On

Shutter

On

Off

Power Mode

4-700W

Full fan speed

400W

Low fan speed

4-700W

Auto fan speed

Display

On

Off

ALPHA WASH 700

Setting

Default

Preset

User

Preset 1

User

Preset 2

User

Preset 3

Load

Preset 2

Save To

Preset 2

Load

Preset 3

Save To

Preset 3

Reset To

Dafault

Go Back

Load

Preset 1

Save To

Preset 1

SHUTTER

Shutter on error

Used for automatically closing the stop/strobe in the event of Pan/Tilt position error.

1) Press

F

- the current settings appear on the display (On or Off).

2) Use the UP

B and DOWN

C keys to enable (On) or disable (Off) automatic stop/strobe closing in the event of Pan/Tilt position error.

3) Press

F to confirm the selection, or LEFT

D to keep current settings.

Dimmer on Shutter

Enables automatic closing of the dimmer when the strobe is completely closed.

1) Press

F

– the current settings appear on the display (On or Off).

2) Use the UP

B and DOWN

C keys to enable (On) or disable (Off) the automatic closing of the dimmer.

3) Press settings.

F to confirm the selection, or LEFT

D to keep current

POWER MODE

Allows you to select a Power Mode from the three available.

1) Press

F

- the current settings appear on the display.

2) Use the UP

B and DOWN

C keys to select one of the following settings:

-

4-700W Full fan speed

: Lamp can change from full-power (700W) to half-power (400W) using the LAMP CONTROL channel. Fans always work at Full speed.

-

400W Low fan speed

: Lamp constantly works in half-power mode

(400W) while the Fan always works at Low speed. With LAMP

CONTROL channel you can only switch the lamp ON and OFF.

-

4-700W Auto fan speed

: Lamp can change from full-power (700W) to half-power (400W) using the LAMP CONTROL channel. Automatically the fans switch from Full speed to Low speed respectively.

3) Press

F to confirm the selection or LEFT

D to keep current setting.

DISPLAY

Used for automatically reduce brightness on the display after about 30 seconds in idle.

1) Press

F

- the current settings appear on the display (On or Off).

2) Use the UP

B and DOWN

C keys to enable (On) or disable (Off) the decreasing of display brightness.

3) Press

F to confirm the selection or LEFT

D to keep current settings.

SETTING

Used to save 3 different settings of the items in the options menu and relative submenus.

1) Press

F

- “Default preset” appears on the display.

2) Use the UP

B and DOWN

C keys to select one of the following configurations:

- Default preset (*)

- User preset 1

- User preset 2

- User Preset 3

3) Press

F

- “Load preset X” appears on the display.

4) Use the UP

B and DOWN

C keys to select:

- Load preset X to recall a previously stored configuration.

- Save to preset X to store the current configuration.

a confirmation message (Are you sure?) appears on the display.

5) Select YES to confirm the selection or NO to keep the current setting and return to the next higher level.

10

(*) DEFAULT PRESET

Used for restoring default values on all options menu items and relevant submenus.

1) Press

F

, a confirmation message (Are you sure?) appears on the display.

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 11

2) Select YES to confirm the selction or NO to keep current setting.

OPTION

Lamp DMX

Invert Pan

DEFAULT

On

Off

Invert Tilt

Swap Pan-Tilt

Encoder Pan-Tilt

Color mixing

Color mixing curve

Fixed Wheel Shortcut

Shutter on error

Dimmer on Shutter

Power Mode

Display

Off

Off

On

CMY

Curve 1

On

Off

Off

4-700 Full fan speed

On

Information

ALPHA WASH 700

System

Errors

Fixture

Hours

Lamp

Hours

Lamp

Strikes

Total XXX

Partial XXX

Reset...

INFORMATION MENU

SYSTEM ERRORS

Shows a list of warnings and messages relevant to errors occurred since the fixtures switching-on.

1) Pressing

F you are allowed to reset the SYSTEM ERRORS list.

A confirmation message (Are you sure you want to clear error list ?) appears on the display.

2) Select YES to reset the list or NO to go back.

FIXTURE HOURS

Used for displaying projector operating hours (total and partial).

1) Press

F

- Hours total and partial appears on the display.

Total counter

Counts the number of projector working life hours (from manufacture to date).

Partial counter

Counts the number of partial projector working life hours since the last reset to date.

2) Press

F to reset partial projector working hours a confirmation message (Are you sure?) appears on the display.

3) Select YES to reset partial projectors counter or NO to keep the current setting and return to the top menu level.

Total XXX

Partial XXX

Reset...

LAMP HOURS

Used for displaying the lamp working hours (total and partial).

1) Press

F

- Hours total and partial appears on the display.

Total counter

Counts the number of projector working hours with the lamp on (from manufacture to date).

Partial counter

Counts the number of lamp working hours since the last reset to date.

2) Press

F to reset partial lamp working hours, a confirmation message

(Are you sure ?) appears on the display.

3) Select YES to reset partial counter or NO to keep the current setting and return to the top menu level

Total XXX

Partial XXX

Reset...

11

LAMP STRIKES

Used for displaying the number of times the lamp was turned on (total and partial).

1) Press

F

- the number of times the lamp was turned on (total and partial) appears on the display.

Total counter

Counts the number of times the lamp was turned on (from manufacture to date).

Partial counter

Counts the number of times the lamp was turned on since the last reset to date.

Continue

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 12

ALPHA WASH 700

System

Version

Board Revis. Hw.rv.

CPU brd x.x.x x.x

com.dev x.x

0: PT-3f x.x x.x

1: 6-Ch x.x x.x

2: 8-Ch x.x x.x

Board

Diagnost.

Board Status Err%

0:PT-3f Good 0.00

1:6-Ch Good 0.00

2:8-Ch Good 0.00

Dmx

Monitor

Fans

Monitor

Fan Speed (RPM)

Ball.In. XXXX

Eff.In XXXX

Lamp XXXX

Network params

Manual

Control

Lamp

On

Off

Reset

No

Yes

Channel

2) Press

F to reset partial lamp strikes hours, a confirmation message

(Are you sure ?) appears on the display.

3) Select YES to reset partial counter or NO to keep the current setting and return to the top menu level

SYSTEM VERSION

Used for displaying the software and hardware version of each board installed in the projector.

CPU brd (CPU board)

0: PT-3f (Pan / Tilt board)

1: 6-Ch (6 channel board)

2: 8-Ch (8 channel board)

BOARD DIAGNOSTIC

Used for displaying the status error of each board installed in the projector:

0: PT-3f (Pan / Tilt board)

1: 6-Ch (6 channel board)

2: 8-Ch (8 channel board)

DMX MONITOR

Used for displaying the projector DMX channel level in bit (Val) and in percentage (Perc).

FANS MONITOR

Used for displaying the speed of each fan installed in the projector:

Ball. IN (Ballast IN Fan)

Eff.IN (Effects IN Fan)

Lamp (Lamp Fan)

NETWORK PARAMS

Allows the "Network" parameters of the projector to be displayed or:

IP address:

Internet Protocol address (two projectors must not have the same IP address)

IP mask: 255.0.0.0

Mac address:

Media Access Control: the projector’s Ethernet Address

12

MANUAL CONTROL

LAMP

Used for turning lamp on and off from the projector control panel.

1) Press

F

- the current settings appear on the display (On or Off).

2) Use the UP

B and DOWN

C keys to turn the lamp on (On) or off (Off)

3) Press

F to confirm the selection or LEFT and return to the top level.

D to keep current settings

RESET

Used for resetting the projector.

1) Press

F to reset the projectors, a confirmation message (Are you sure

?) appears on the display.

2) Select YES to starting reset the fixture or NO to keep the current setting and return to the top menu level.

CHANNEL

Used for setting channel levels from the projector control panel.

1) Press

F

- the first channel appears on the display.

2) Use the UP

3) Press

B and DOWN

C keys to select the required channel:

F and use the UP

B and DOWN

C keys to select the required DMX level (value between 0 and 255).

4) Press LEFT

D to return to the top menu level.

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 13

Test

Pan-Tilt

Colour

Beam

All

TEST MENU

TEST

Allows you to check the proper functioning of effects.

1) Press

F to return to the top menu level.

2) Use the UP

3) Press

B and DOWN

C keys to select the required test.

F to confirm the selection or LEFT

D to keep current settings.

Test sequence:

Pan - Tilt effects (Pan & Tilt)

Colour effects (CMY / CTO / Colour wheel)

Beam effects (Stopper-Strobe / Dimmer / Beam shaper / Zoom)

All effects

Advanced

Code

1234

Upload

Firmware

Transfer the firmware on all the connected fixtures ?

Are you sure ?

Yes/No

Setup

Model

Changing to a wrong model may damage the fixture.

Are you sure ?

Yes/No

Calibration

ADVANCED MENU

To enable the "Advanced Menu" set up the "Access code" (1234) using the

UP

B

, DOWN

C

, RIGHT

E keys.

Press

F

- "Menu advanced" appears on the display

UP LOAD FIRMWARE

Allows you to transfer the firmware from 1 fixture to all the connected fixtures.

1) Press

F

, a confirmation message appears on the display.

2) Select YES to start the firmware loading or NO to keep the current setting and return to the top menu level

SETUP MODEL

Allows you to change the default model of projector.

1) Press

F a confirmation message appears on the display.

2) Select YES to define the model of projector or NO to keep the current setting and return to the top menu level.

CALIBRATION

Allows you to adjust effects from the control panel to obtain perfect uniformity between the projectors.

1) Press

F

- “channels” appears on the display.

2) Using the UP regulate.

3) Press

B and DOWN

C keys, select the effect you wish to

F and use the RIGHT

E

, UP

B and DOWN

C buttons to make the adjustment by setting a value between 0 and 255.

4) Press

F to confirm the selection or LEFT

D to keep current settings and return to the top level.

FACTORY DEFAULT

Allows you to restore default values of all channels (128).

1) Press

F

– a confirmation message appears on the display (Reset calibration to factory default ?).

2) Select YES to reset calibration to factory default or NO to keep the current setting and return to the top menu level.

ALPHA WASH 700

13

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 14

10

1

1/4 Turn

MAINTENANCE

2

11

1

3

4

Locking and releasing Pan and Tilt movements

- Refer to the instructions in the UNPACKING AND PREPARATION section.

Opening the head covers

- Fig. 10.

Closing the head covers

- Fig. 11.

2

1/4 Turn

ALPHA WASH 700

14

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 15

12 13

1

A

Upper Side

1

2

Opening and closing lamp compartment

- Fig. 12

14

OK NO NO

Lamp regulation

- Fig. 14

To centre the lamp, turn the three adjusting screws as shown in the figure.

ALPHA WASH 700

15

2

A

Lower Side

3

A

Lamp change

- Fig 13

Take the new lamp out of its package and insert in the fitting.

WARNING: do not touch the lamp’s envelope with bare hands.

Should this happen, clean the bulb with a cloth soaked in alcohol and dry it with a clean, dry cloth.

Upper Side

Lower Side

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 16

15

Upper Side

Parts requiring frequent cleaning.

Periodical cleaning

- Fig. 15

To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The frequency with which the following operations are to be carried out depends on various factors, such as the amount of the effects and the quality of the working environment (air humidity, presence of dust, salinity, etc.).

Use a soft cloth dampened with any detergent liquid for cleaning glass to remove the dirt from the reflectors and filters. It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations:

General cleaning of internal parts.

Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Clay Paky.

General visual check of the internal components, cabling, mechanical parts, etc.

Electrical, photometric and functional checks; eventual repairs.

ALPHA WASH 700

16

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 17

16

Lower Side

1

Thermostat

2

Upper Side

3

Extraction of the effect modules: Preliminary operations

- Fig. 16

4

ALPHA WASH 700

17

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 18

17

Upper Side

1

Upper Side

2

Extraction of the effect modules

- Fig. 17

IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged.

Insertion of the effect modules:

Repeat the operations indicated in Fig. 16 - 17 - 18 and 19 in reverse order.

ALPHA WASH 700

18

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 19

18

Lower Side

3

4

Upper Side

Upper Side

5

Extraction of the effect modules

- Fig. 18

IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged.

Insertion of the effect modules:

Repeat the operations indicated in Fig. 16 - 17 - 18 and 19 in reverse order.

ALPHA WASH 700

19

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 20

19

Lower Side

6

7

Upper Side

Upper Side

8

Extraction of the effect modules

- Fig. 19

IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged.

Insertion of the effect modules:

Repeat the operations indicated in Fig. 16 - 17 - 18 and 19 in reverse order.

ALPHA WASH 700

20

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 21

575

(22.64")

385

(15,16")

410

(16,14")

375

(14.76")

50

(1,97")

220

(8,66")

220

(8,66")

390

(15,35")

405

(15.94")

505

(19,88")

Power supplies available

100-120V 50/60Hz

200-240V 50/60Hz

Input power

• 1050VA a 230V 50Hz.

Lamp

Discharge lamp.

• Type MSR GOLD 700/2

- Cap PGJX28

- Colour temperature 7200 K

- Luminous flux 50000 lm

- Average life 750 h

- Any working position

Motors

17 stepper motors, operating with microsteps, totally microprocessor controlled.

Optical unit

• Elliptic reflector with high luminous efficiency

Channels

Max 21 control channels.

Inputs

• DMX 512

Movable body

• Movement by means of two stepper motors, controlled by microprocessor.

• Automatic repositioning of PAN and TILT after accidental movement not controlled by control unit.

• Travel:

- PAN = 540°

- TILT = 250°

• Maximum speeds:

- PAN = 3.20 (Normal) / 2.90 (Fast)

- TILT = 1.89 (normal) / 1.75 (Fast)

• Resolution:

- PAN = 2.11°

- PAN FINE = 0.008°

- TILT = 0.98°

- TILT FINE = 0.004°

TECHNICAL INFORMATION

IP20 protection rating

• Protected against the entry of solid bodies larger than 12mm (0.47”).

• No protection against the entry of liquids.

CE Marking

In conformity with the European Union Low Voltage

Directive 2006/95/CE and Electromagnetic compatibility Directive 2004/108/CE.

Safety Devices

• Bipolar circuit breaker with thermal protection.

• Automatic break in power supply in case of overheating or failed operation of cooling system.

Cooling

Forced ventilation with axial fans.

Body

• Aluminium structure with die-cast plastic cover.

• Two side handles for transportation.

• Device locking PAN and TILT mechanisms for transportation and maintenance.

Working position

Functioning in any position.

Weight

• about 20.60 Kg (45lbs 5ozs).

CAUSE AND SOLUTION OF PROBLEMS

THE PROJECTOR WILL NOT SWITCH ON

ELECTRONICS NON-OPERATIONAL

DEFECTIVE PROJECTION

REDUCED LUMINOSITY

POSSIBLE CAUSES

No mains supply.

Lamp exhausted or defective.

Signal transmission cable faulty or disconnected.

Incorrect addressing.

Fault in the electronic circuits.

Lenses or reflector broken

Dust or grease deposited.

CHECKS AND REMEDIES

Check the power supply voltage.

Replace the lamp. (See instructions).

Replace the cables.

Check addresses (see instructions).

Call an authorised technician.

Call an authorised technician.

Clean (see instructions).

PROBLEMS

ALPHA WASH 700

21

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 22

CHANNEL FUNCTION

ALPHA WASH 700

CHANNEL

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

STANDARD

CYAN

MAGENTA

YELLOW

CTO

COLOUR WHEEL

STOP / STROBE

DIMMER

DIMMER FINE

BEAM SHAPER INSERTION

BEAM SHAPER ROTATION

ZOOM

PAN

PAN FINE

TILT

TILT FINE

FUNCTION

RESET

LAMP CONTROL (with Option "Lamp Dmx" ON)

19

20

21

CHANNEL MODE

VECTOR

CYAN

MAGENTA

YELLOW

CTO

COLOUR WHEEL

STOP / STROBE

DIMMER

DIMMER FINE

BEAM SHAPER INSERTION

BEAM SHAPER ROTATION

ZOOM

PAN

PAN FINE

TILT

TILT FINE

FUNCTION

RESET

LAMP CONTROL (with Option "Lamp Dmx" ON)

PAN - TILT TIME

COLOUR TIME

BEAM TIME

ALPHA WASH 700

22

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 23

NOTE: On conclusion of resetting in case of absence of DMX signal, Pan & Tilt move to the "Home" position (Pan 50% - Tilt 50%) all the others channels stay at 0%.

• STOP / STROBE - channel 6 • COLOUR MIXING - channel 1 - 2 - 3

Operation with option color mixing: RGB

CHANNEL 1 CHANNEL 2 CHANNEL 3

BIT

255

%

100

EFFECT

COLOUR EXCLUDED

BIT % EFFECT

252 - 255

98.7 - 100

OPEN

239 - 251 93.7 - 98.2

RANDOM FAST STROBE

226 - 238

88.7 - 93.2

RANDOM MEDIUM STROBE

213 - 225 83.7 - 88.2

RANDOM SLOW STROBE

208 - 212 81.7 - 83.2

OPEN

207 81.2

FAST PULSATION

108 42.5

SLOW PULSATION

104 - 107 41.0 - 42.0

OPEN

103 40.5

FAST STROBE (12 flash/sec)

0

0.0

COLOUR INSERTED

CYAN MAGENTA YELLOW

IMPORTANT:

The lamp dim to half power 1 second after all the 3 channels stay at 0% level. The lamp goes back to full power when the channels level is put higher than 0%.

Operation with option color mixing: CMY

CHANNEL 1 CHANNEL 2 CHANNEL 3

BIT

255

%

100

EFFECT

COLOUR INSERTED

4

0 - 3

1.7

0.0 - 1.2

SLOW STROBE (1 flash/sec)

CLOSED

IMPORTANT:

The lamp dim to half power 1 second after the channel stay at

0% level. The lamp goes back to full power when the channel level is put higher than 0%.

• DIMMER - channel 7

BIT

255

%

100

EFFECT

MAGENTA YELLOW

0 0.0

COLOUR EXCLUDED

CYAN

IMPORTANT:

The lamp dim to half power 1 second after all the 3 channels stay at 100% level. The lamp goes back to full power when the channels level is put lower than 100%.

• C.T.O. - channel 4

CHANNEL 4

BIT

255

%

100

EFFECT

FILTER INSERTED

0 0.0

The lamp is linearly dimmed from full power to half power electronicaly and mechanically from half power to off.

• DIMMER FINE - channel 8

BIT

255

%

100

EFFECT

CTO

• COLOUR WHEEL - channel 5

0 0.0

FILTER EXCLUDED

BIT

255

%

100

EFFECT

FAST ROTATION (160 rpm)

0 0.0

• BEAM SHAPER INSERTION - channel 9

BIT

170-255

%

EFFECT

66.7-100 SHAPER 2

ALPHA WASH 700

37

30

22

15

8

0

75

67

60

52

45

128

127

120

112

105

97

90

82

50.0

49.7

47.0

44.0

41.2

38.0

35.0

32.0

29.5

26.2

23.7

20.5

17.5

14.2

11.7

8.7

6.0

3.2

0.0

SLO W ROTATION (0.2 rpm)

BLUE + WHITE

BLUE

ORANGE + BLUE

ORANGE

AQUAMARINE + ORANGE

AQUAMARINE

LAVENDER + AQUAMARINE

LAVENDER

LIGHT GREEN + LAVENDER

LIGHT GREEN

GREEN + LIGHT GREEN

GREEN

CTB + GREEN

CTB

RED + CTB

RED

WHITE + RED

WHITE

23

85-169 33.2-66.2

SHAPER 1

0 - 84 0.0 - 33.0

WHITE

Continue

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 24

• BEAM SHAPER ROTATION - channel 10

STOP

540°

360°

BIT

255

%

100

EFFECT

FAST ROTATION (120 rpm)

193 75.5

191 - 192 74.7 - 75.0

190 74.2

SLOW ROTATION (3 rph)

STOP

SLOW ROTATION (3 rph)

128

127

105

84

63

42

21

0

50.0

49.7

41.7

33.0

24.7

16.2

8.2

0.0

FAST ROTATION (120 rpm)

POSITION 540 °

POSITION 450

°

POSITION 360

°

POSITION 270

°

POSITION 180

°

POSITION 90 °

POSITION 0 °

• ZOOM - channel 11

BIT

255

%

100

EFFECT

WIDE BEAM

• PAN FINE - channel 13

Operation with option InvertPan

G

Off

(Tilt conventionally represented at 14% and option Invert Tilt

G

Off)

BIT

255

%

100

0 0.0

Operation with option InvertPan

G

On

(Tilt conventionally represented at 14% and option Invert Tilt

G

Off)

BIT

255

%

100

• PAN - channel 12

Operation with option InvertPan

G

Off

0 0.0

NARROW BEAM

(Tilt conventionally represented at 14% and option Invert Tilt

BIT

255

%

100

G

Off)

0 0.0

• TILT - channel 14

Operation with option Invert Tilt

G

Off

(Pan conventionally represented at 0% and option Invert Pan

G

Off)

BIT

255

%

100

128 50.0

0 0.0

Operation with option InvertPan

G

On

(Tilt conventionally represented at 14% and option Invert Tilt

G

Off)

BIT

255

%

100

ALPHA WASH 700

0 0.0

24

0 0.0

Operation with option Invert Tilt

G

On

(Pan conventionally represented at 0% and option Invert Pan

G

Off)

BIT

255

%

100

128 50.0

0 0.0

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 25

• TILT FINE - channel 15

Operation with option Invert Tilt

G

Off

(Pan conventionally represented at 0% and option Invert Pan

BIT

255

%

100

G

Off)

0 0.0

Operation with option Invert Tilt

G

On

(Pan conventionally represented at 0% and option Invert Pan

G

Off)

BIT

255

%

100

• LAMP CONTROL (only with option LAMP DMX On) - channel: 18

IMPORTANT:

Alpha Wash 700 is not provided with hot restrike igniter

ON

ON

ON

ON

OFF

OFF

BIT

255

180

179

101

100

26

25

0

%

100

70.5

70.0

39.5

39.0

10.0

9.7

0.0

EFFECT

LAMP ON (FULL POWER)

Lamp ignition after 5 s in full power levels.

Immediate transition from half to full power.

LAMP ON (FULL POWER)

LAMP ON (HALF POWER)

Immediate transition from full to half power.

Lamp ignition not allowed in half power.

LAMP ON (HALF POWER)

LAMP OFF

Lamp switch off passing throug the unused range and staying 5 s in

Lamp OFF levels.

LAMP OFF

UNUSED RANGE

0 0.0

• FUNCTION - channel: 16

BIT

255

%

100

UNUSED RANGE

EFFECT

52 20.5

51 20.0

LINEAR (DEFAULT)

39 15.0

26 10.0

CONVENTIONAL

NORMAL SPEED

FAST SPEED (DEFAULT) 13 5.0

0-12 0.0-4.7

UNUSED RANGE

DIMMER CURVE

FUNCTION

PAN-TILT

FUNCTION

The functions are actived passing through the "unused range" and staying 5 seconds in necessary level

• RESET - channel: 17

BIT

255

%

100

EFFECT

COMPLETE RESET

Complete reset is activated passing throug the unused range and staying

5 seconds in complete reset levels.

128

127

50.0

49.7

COMPLETE RESET

PAN / TILT RESET

Pan / Tilt reset is activated passing throug the unused range and staying

5 seconds in Pan / Tilt reset levels.

77 30.0

76 29.7

26 10.0

25 9.7

0 0.0

PAN / TILT RESET

EFFECTS RESET

Effects reset is activated passing throug the unused range and staying

5 seconds in Effects reset levels.

EFFECTS RESET

UNUSED RANGE

ALPHA WASH 700

25

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 26

TIMING CHANNELS

Timing Channel Channel function

19 Pan - Tilt time Pan - Tilt - (Pan fine - Tilt fine)

20 Colour time CMY - CTO - Colour wheel

21 Beam time Dimmer - Zoom

TIME TABLE

58

59

60

61 14

62

63

64

65

66 16

67

68

69

70

71 18

72

73

74

75

76 20

77

78

79 21

80

81

82

83

84 23

85

BIT Seconds

43 8.6

44 8.8

45 9

46 9.2

47 9.4

48 9.6

49 9.8

50 10

51 10.2

52 10.4

53 10.6

54

55

56

57

25 5

26 5.2

27 5.4

28 5.6

29 5.8

30 6

31 6.2

32 6.4

33 6.6

34 6.8

35 7

36 7.2

37 7.4

38 7.6

39 7.8

40 8

41 8.2

42 8.4

BIT Seconds

0 Full

1 0.2

2 0.4

3 0.6

4 0.8

5 1

6 1.2

7 1.4

8 1.6

9 1.8

10 2

11 2.2

12 2.4

13 2.6

14 2.8

15 3

16 3.2

17 3.4

18 3.6

19 3.8

20 4

21 4.2

22 4.4

23 4.6

24 4.8

102 30

103

104

105

106

107 32

108

109

110

111

112 34

113

114

115

116

117 36

118

119

120

121

122 38

123

124

125 39

126

127

128

BIT Seconds

86

87

88

89 25

90

91

92

93

94 27

95

96

97

98

99 29

100

101

BIT Seconds

172

173 58

174

175

176 59

177

178

179

180

181 65

182

183

184

185

186 75

187

188

189

190

191 85

192

193

194

195

196 95

197

198

200

201 110

202

203

204 120

205

206

208

209 140

210

211

213

214 160

215

145 47

146

147

148

149

150 49

151

152

153 50

154

155

156

157

158 52

159

160

161

162

BIT Seconds

129

130 41

131

132

133

134

135 43

136

137

138

139

140 45

141

142

143

144

163 54

164

165

166

167

168 56

169

170

171

BIT Seconds

216

217

218

219 180

220

221

222

223

224 200

225

226

227 210

228

229

230

231

232 230

233

234

235

236

237 250

238

239

240

241

242 270

243

244

245

246

247 290

248

249

250

251

252

253

254

Follow cue

Data

ALPHA WASH 700

26

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 27

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 28

CLAY PAKY

S.p.A.

- Via Pastrengo, 3/b - 24068 Seriate (BG) Italy - Tel. +39-035-654311- Fax +39-035-301876 -

www.claypaky.it

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement