R&S®ZVB Vector Network Analyzers

R&S®ZVB Vector Network Analyzers

R&S®ZVB

Vector Network Analyzer

Specifications

Umschlag_ZVB.indd 1 06.06.2011 10:34:25

Version 08.02, June 2011

CONTENTS

Definitions ....................................................................................................................................................................... 3

Specifications.................................................................................................................................................................. 4

Measurement range................................................................................................................................................................................4

Measurement speed ...............................................................................................................................................................................6

Measurement accuracy...........................................................................................................................................................................7

Effective system data............................................................................................................................................................................10

Test port output .....................................................................................................................................................................................11

Test port input .......................................................................................................................................................................................14

Additional front panel connectors..........................................................................................................................................................15

Display ..................................................................................................................................................................................................15

Rear panel connectors ..........................................................................................................................................................................15

Options..................................................................................................................................................................................................17

General data .........................................................................................................................................................................................18

Ordering information .................................................................................................................................................... 19

2 R&S

®

ZVB Vector Network Analyzer

Version 08.02, June 2011

Definitions

General

Product data applies under the following conditions:

Three hours storage at ambient temperature followed by 30 minutes warm-up operation environmental conditions met

Recommended calibration interval adhered to

All internal automatic adjustments performed, if applicable

Specifications with limits

Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as < ,

≤, > , ≥, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable.

Specifications without limits

Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design.

Typical data (typ.)

Characterizes product performance by means of representative information for the given parameter. When marked with < , > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean value.

Nominal values (nom.)

Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to typical data, a statistical evaluation does not take place and the parameter is not tested during production.

Measured values (meas.)

Characterize expected product performance by means of measurement results gained from individual samples.

Uncertainties

Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account environmental conditions, aging, wear and tear.

Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz.

Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer 3

Version 08.02, June 2011

Specifications

Measurement range

Impedance

Test port connector R&S

®

ZVB4 and R&S

®

ZVB8

R&S

®

ZVB14 and R&S

®

ZVB20

Number of test ports

Frequency range

Static frequency accuracy

Frequency resolution

Number of measurement points

Measurement bandwidths

Dynamic range of the R&S

®

ZVB4 two-port model and the R&S

®

ZVB8 two-port model

(without optional step attenuators)

Dynamic range of the R&S

®

ZVB4 four-port model and the R&S

®

ZVB8 four-port model

(without optional step attenuators)

R&S

®

ZVB4

R&S

®

ZVB8

R&S

®

ZVB14

R&S

®

ZVB20 without optional oven quartz with optional oven quartz per trace

1/2/5 steps from PORT 1 to PORT 2

300 kHz to 5 MHz

50

Ω type N, female

3.5 mm, male

2 or 4

300 kHz to 4 GHz

300 kHz to 8 GHz

10 MHz to 14 GHz

10 MHz to 20 GHz

8 × 10

–6

1 × 10

–7

1 Hz

2 to 60001

1 Hz to 500 kHz

> 80 dB, typ. 100 dB

5 MHz to 100 MHz

100 MHz to 4 GHz

4 GHz to 7 GHz (R&S

®

ZVB8 only)

7 GHz to 7.5 GHz (R&S

®

ZVB8 only)

7.5 GHz to 8 GHz (R&S

®

ZVB8 only)

> 100 dB, typ. 120 dB

> 120 dB, typ. 130 dB

> 117 dB, typ. 127 dB

> 115 dB, typ. 120 dB

> 108 dB, typ. 118 dB from PORT 1 to PORT 2 and from PORT 3 to PORT 4 (for four-port models only)

Dynamic range of the R&S

®

ZVB14

300 kHz to 5 MHz

5 MHz to 100 MHz

> 80 dB, typ. 100 dB

> 100 dB, typ. 120 dB

100 MHz to 500 MHz

500 MHz to 4 GHz

4 GHz to 7 GHz (R&S

®

ZVB8 only)

7 GHz to 7.5 GHz (R&S

®

ZVB8 only)

7.5 GHz to 8 GHz (R&S

®

ZVB8 only)

> 120 dB, typ. 130 dB

> 123 dB, typ. 130 dB

> 120 dB, typ. 130 dB

> 115 dB, typ. 125 dB

> 108 dB, typ. 125 dB from PORT 1 to PORT 2 and from PORT 3 to PORT 4 (for four-port model only)

10 MHz to 100 MHz

100 MHz to 700 MHz

700 MHz to 8 GHz

> 80 dB, typ. 110 dB

> 100 dB, typ. 130 dB

> 120 dB, typ. 133 dB

Dynamic range of the R&S

®

ZVB20

8 GHz to 14 GHz > 110 dB, typ. 122 dB from PORT 1 to PORT 2 and from PORT 3 to PORT 4 (for four-port model only)

10 MHz to 100 MHz

100 MHz to 700 MHz

> 80 dB, typ. 110 dB

> 100 dB, typ. 130 dB

700 MHz to 8 GHz

8 GHz to 20 GHz

> 120 dB, typ. 133 dB

> 110 dB, typ. 122 dB

The dynamic range is defined as the difference between the actually available maximum source power and the RMS value of the data trace of the transmission magnitude, which is produced by noise and crosstalk with the test ports short-circuited. The specification applies at 10 Hz measurement bandwidth and without system error correction. The dynamic range can be increased by using a measurement bandwidth of 1 Hz.

4 Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer

Version 08.02, June 2011

Dynamic range in dB versus frequency in GHz of the R&S

®

ZVB4.

Dynamic range in dB versus frequency in GHz of the R&S

®

ZVB8.

Dynamic range in dB versus frequency in GHz of the R&S

®

ZVB14 (up to 14 GHz) and the R&S

®

ZVB20.

Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer 5

Version 08.02, June 2011

Measurement speed

Measurement time

Measurement time per point

Data transfer time for 201 measurement points, with span 100 MHz, 500 kHz measurement bandwidth,

ALC and display switched OFF with center frequency 1.1 GHz with center frequency 5.1 GHz

500 kHz measurement bandwidth,

CW mode

< 6 ms

< 4.5 ms

< 4.5 µs for 201 measurement points via IEC/IEEE bus via VX11 over 100 Mbit/s LAN via RSIB over 100 Mbit/s LAN

< 2.9 ms

< 1.3 ms

< 0.7 ms

< 6 ms

Time for measurement and data transfer for 201 measurement points, with start frequency 1 GHz, stop frequency 1.1 GHz,

500 kHz measurement bandwidth, and display switched OFF

(No additional time for data transfer is needed, as this occurs simultaneously during the measurement.)

Switching time between channels

Switching time between two preloaded instrument settings with not more than 2001 points with not more than 2001 points

< 1 ms

< 10 ms

Typical sweep times versus number of measurement points

Start frequency 5 GHz, stop frequency 5.2 GHz, ALC OFF, and a measurement bandwidth of 100 kHz

With full one-port calibration or with correction switched OFF 2.4 ms 3.9 ms 6.3 ms 11 ms 20.4 ms

With TOSM calibration 4.7 ms 8.6 ms 16.4 ms 32.4 ms

Start frequency 6 GHz, stop frequency 8 GHz, ALC OFF, and a measurement bandwidth of 100 kHz

65 ms

40.2 ms

170 ms

With full one-port calibration or with correction switched OFF 3.4 ms 6.2 ms 11 ms 17.3 ms 28.2 ms 49 ms

With TOSM calibration 5.3 ms 9.8 ms 18 ms 33 ms 63 ms 160 ms

Start frequency 10 MHz, stop frequency 4 GHz (R&S

®

ZVB4), 8 GHz (R&S

®

ZVB8), 14 GHz (R&S

®

ZVB14), or 20 GHz (R&S

®

ZVB20),

ALC OFF, and a measurement bandwidth of 100 kHz

With full one-port calibration or with correction switched OFF

With TOSM calibration

8.4 ms

10.3 ms

12.6 ms

16.6 ms

19.5 ms

28 ms

30.5 ms

47 ms

53.2 ms

81 ms

88.2 ms

190 ms

6 Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer

Version 08.02, June 2011

Measurement accuracy

This data is valid between +18 °C and +28 °C, provided the temperature has not varied by more than 1 K after calibration.

Validity of the data is conditional on the use of a suitable calibration kit. This calibration kit is used to achieve the effective system data specified below. Frequency points, measurement bandwidth, and sweep time have to be identical for measurement and calibration

(no interpolation allowed).

Accuracy of transmission measurements

R&S

®

ZVB4 and R&S

®

ZVB8

300 kHz to 1 MHz

1 MHz to 50 MHz

+15 dB to –45 dB

+15 dB to –30 dB

–30 dB to –45 dB

Above 50 MHz +15 dB to +5 dB

+5 dB to –55 dB

–55 dB to –70 dB

–70 dB to –85 dB

R&S

®

ZVB14 and R&S

®

ZVB20

10 MHz to 50 MHz

50 MHz to 400 MHz

+15 dB to –30 dB

400 MHz to 700 MHz

+15 dB to –30 dB

–30 dB to –45 dB

+15 dB to +5 dB

+5 dB to –35 dB

–35 dB to –50 dB

–50 dB to –65 dB

< 1 dB or < 6°

< 0.2 dB or < 2°

< 1 dB or < 6°

< 0.2 dB or < 2°

< 0.1 dB or < 1°

< 0.2 dB or < 2°

< 1 dB or < 6°

< 1 dB or < 6°

< 0.2 dB or < 2°

< 1 dB or < 6°

< 0.2 dB or < 2°

< 0.1 dB or < 1°

< 0.2 dB or < 2°

< 1 dB or < 6°

700 MHz to 8 GHz

Above 8 GHz

+15 dB to +5 dB

+5 dB to –55 dB

–55 dB to –70 dB

–70 dB to –85 dB

+15 dB to +5 dB

< 0.2 dB or < 2°

< 0.1 dB or < 1°

< 0.2 dB or < 2°

< 1 dB or < 6°

< 0.2 dB or < 2°

+5 dB to –35 dB

–35 dB to –50 dB

< 0.1 dB or < 1°

< 0.2 dB or < 2°

–50 dB to –65 dB < 1 dB or < 6°

Specifications are based on a matched DUT, a measurement bandwidth of 10 Hz, and a nominal source power of –10 dBm.

Magnitude

Phase

10

1

0.1

0

0.01

-20 -40 -60 -80

Transmission coefficient in dB

-100

100

10

1

0

0.1

-20 -40 -60 -80

Transmission coefficient in dB

-100

Typical accuracy of transmission magnitude and transmission phase measurements of the R&S

®

ZVB4 and the R&S

®

ZVB8 in the frequency range from 300 kHz to 50 MHz.

Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer 7

Version 08.02, June 2011

Magnitude

10

1

0.1

0

0.01

-20 -40 -60 -80

Transmission coefficient in dB

-100

100

10

1

Phase

0

0.1

-20 -40 -60 -80

Transmission coefficient in dB

-100

Typical accuracy of transmission magnitude and transmission phase measurements of the R&S

®

ZVB8 in the frequency range from 50 MHz to 8 GHz.

Magnitude

Phase

10

100

10 1

0.1

1

0

0.01

-20 -40 -60 -80

Transmission coefficient in dB

-100

0

0.1

-20 -40 -60 -80

Transmission coefficient in dB

-100

Typical accuracy of transmission magnitude and transmission phase measurements of the R&S

®

ZVB14 and the R&S

®

ZVB20 in the frequency range from 10 MHz to 700 MHz.

10

1

0.1

100

10

1

0

0.1

-20

0

0.01

-20 -40 -60 -80 -100

-40 -60 -80 -100

Typical accuracy of transmission magnitude and transmission phase measurements of the R&S

®

ZVB14 (in the frequency range from

700 MHz to 14 GHz) and the R&S

®

ZVB20 (in the frequency range from 700 MHz to 20 GHz).

8 Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer

Version 08.02, June 2011

Accuracy of reflection measurements

R&S

®

ZVB4 and R&S

®

ZVB8

Above 300 kHz +10 dB to +3 dB

+3 dB to –15 dB

–15 dB to –25 dB

–25 dB to –35 dB

< 0.6 dB or < 4°

< 0.4 dB or < 3°

< 1 dB or < 6°

< 3 dB or < 20°

R&S

®

ZVB14 and R&S

®

ZVB20

10 MHz to 50 MHz +3 dB to –15 dB

–15 dB to –25 dB

< 1 dB or < 6°

< 3 dB or < 20°

Above 50 MHz +10 dB to +3 dB

+3 dB to –15 dB

–15 dB to –25 dB

–25 dB to –35 dB

< 0.6 dB or < 4°

< 0.4 dB or < 3°

< 1 dB or < 6°

< 3 dB or < 20°

Specifications are based on an isolating DUT, a measurement bandwidth of 10 Hz, and a nominal source power of –10 dBm.

Magnitude

Phase

0.05

0.04

0.03

0.02

0.01

0.00

0 0.2

0.4

0.6

0.8

Reflection coefficient (linear)

1

10

8

6

4

2

0

0 0.2

0.4

0.6

Reflection coefficient (linear)

0.8

1

Trace stability

Trace noise of S

11

(RMS)

Typical accuracy of reflection magnitude and reflection phase measurements of the R&S of the R&S

®

®

ZVB4 in the frequency range from 300 kHz to 4 GHz,

ZVB8 in the frequency range from 300 kHz to 8 GHz, of the R&S

®

ZVB14 in the frequency range from 50 MHz to 14 GHz, and of the R&S

®

ZVB20 in the frequency range from 50 MHz to 20 GHz.

Temperature dependance at 0 dBm source power, 0 dB reflection, and 1 kHz measurement bandwidth

R&S

®

ZVB4 and R&S

®

ZVB8 above 300 kHz

R&S

®

ZVB14 and R&S

®

ZVB20

< 0.004 dB, typ. 0.001 dB

700 MHz to 8 GHz above 8 GHz

< 0.004 dB, typ. 0.001 dB

< 0.015 dB, typ. 0.004 dB at 0 dB transmission or reflection < 0.05 dB/K or < 0.4°/K

Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer 9

Version 08.02, June 2011

Effective system data

This data is valid between +18 °C and +28 °C, provided the temperature has not varied by more than 1 K after calibration. The data is based on a measurement bandwidth of 10 Hz and system error calibration by means of a suitable calibration kit. Frequency points, measurement bandwidth, and sweep time have to be identical for measurement and calibration (no interpolation allowed).

R&S

®

ZVB4 and R&S

®

ZVB8

Directivity

Source match

Reflection tracking

Load match

Transmission tracking

300 kHz to 4 GHz

4 GHz to 8 GHz (R&S

®

ZVB8 only)

300 kHz to 4 GHz

4 GHz to 8 GHz (R&S

®

ZVB8 only)

300 kHz to 4 GHz

4 GHz to 8 GHz (R&S

®

ZVB8 only)

300 kHz to 4 GHz

4 GHz to 8 GHz (R&S

®

ZVB8 only)

300 kHz to 4 GHz

4 GHz to 8 GHz (R&S

®

ZVB8 only)

> 46 dB, typ. 50 dB

> 40 dB, typ. 50 dB

> 40 dB, typ. 46 dB

> 36 dB, typ. 40 dB

< 0.04 dB, typ. 0.01 dB

< 0.1 dB, typ. 0.01 dB

> 46 dB, typ. 50 dB

> 40 dB, typ. 46 dB

< 0.06 dB, typ. 0.01 dB

< 0.1 dB, typ. 0.05 dB

R&S

®

ZVB14 and R&S

®

ZVB20

Directivity

Source match

Reflection tracking

Load match

Transmission tracking

10 MHz to 700 MHz above 700 MHz

10 MHz to 700 MHz above 700 MHz

10 MHz to 700 MHz above 700 MHz

10 MHz to 700 MHz above 700 MHz

10 MHz to 700 MHz above 700 MHz

> 36 dB, typ. 40 dB

> 40 dB, typ. 50 dB

> 30 dB, typ. 48 dB

> 30 dB, typ. 48 dB

< 0.3 dB, typ. 0.05 dB

< 0.3 dB, typ. 0.05 dB

> 36 dB, typ. 40 dB

> 40 dB, typ. 50 dB

< 0.2 dB, typ. 0.1 dB

< 0.1 dB, typ. 0.05 dB

10 Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer

Version 08.02, June 2011

Test port output

Power range

(without optional step attenuators)

Power accuracy

(with ALC ON and without power calibration)

Power linearity

Power resolution

Harmonics

(output power referenced to maximum specified output power)

R&S

®

ZVB4 and R&S

®

ZVB8

300 kHz to 50 MHz

50 MHz to 4 GHz

4 GHz to 7 GHz (R&S

7 GHz to 8 GHz (R&S

®

®

ZVB8 only)

ZVB8 only)

–40 dBm to +10 dBm, typ. –45 dBm to +14 dBm

–40 dBm to +13 dBm, typ. –45 dBm to +15 dBm

–40 dBm to +10 dBm, typ. –45 dBm to +13 dBm

–40 dBm to +8 dBm, typ. –45 dBm to +12 dBm

R&S

®

ZVB14 and R&S

®

ZVB20

10 MHz to 13 GHz above 13 GHz

–30 dBm to +10 dBm, typ. –40 dBm to +15 dBm

–30 dBm to +5 dBm, typ. –40 dBm to +10 dBm

R&S

®

ZVB4 and R&S

®

ZVB8 at –10 dBm in temperature range +18 °C to +28 °C above 50 MHz

R&S

®

ZVB14 and R&S

®

ZVB20 at –10 dBm in temperature range +18 °C to +28 °C above 50 MHz referenced to –10 dBm in temperature range +18 °C to +28 °C

R&S

®

ZVB4 and R&S

®

ZVB8

< 2 dB

< 0.8 dB, typ. 0.3 dB

< 3 dB

< 0.8 dB, typ. 0.3 dB

< 2 dB above 50 MHz

R&S

®

ZVB14 and R&S

®

ZVB20 above 500 MHz

R&S

®

ZVB4 and R&S

®

ZVB8

300 kHz to 50 MHz at –3 dB

< 0.8 dB, typ. 0.2 dB

< 0.8 dB, typ. 0.2 dB

0.01 dB typ. < –30 dBc

50 MHz to 4 GHz at –5 dB < –20 dBc, typ. < –30 dBc

4 GHz to 7 GHz at –2 dB (R&S

®

ZVB8) < –20 dBc, typ. < –30 dBc

7 GHz to 8 GHz at 0 dB (R&S

®

ZVB8)

R&S

®

ZVB14 and R&S

®

ZVB20

< –20 dBc, typ. < –30 dBc

10 MHz to 50 MHz at –3 dB typ. < –30 dBc

50 MHz to 13 GHz at 0 dB above 13 GHz at 0 dB

< –20 dBc, typ. < –30 dBc

< –20 dBc, typ. < –30 dBc

Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer 11

Version 08.02, June 2011

Maximum output power in dBm versus frequency in GHz of the R&S

®

ZVB4.

Maximum output power in dBm versus frequency in GHz of the R&S

®

ZVB8.

Maximum output power in dBm versus frequency in GHz of the R&S

®

ZVB14 (up to 14 GHz) and the R&S

®

ZVB20.

12 Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer

Version 08.02, June 2011

Output power accuracy in dB versus frequency in GHz of the R&S

®

ZVB4.

Output power accuracy in dB versus frequency in GHz of the R&S

®

ZVB8.

Output power accuracy in dB versus frequency in GHz of the R&S

®

ZVB14 (up to 14 GHz) and the R&S

®

ZVB20.

Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer 13

Version 08.02, June 2011

Test port input

Match

Maximum nominal input level

Power measurement accuracy

Receiver linearity without system error correction

R&S

®

ZVB4

300 kHz to 4 GHz

R&S

®

ZVB8

300 kHz to 7 GHz

7 GHz to 8 GHz

R&S

®

ZVB14 and R&S

®

ZVB20

10 MHz to 50 MHz

50 MHz to 2 GHz above 2 GHz

R&S

®

ZVB4 and R&S

®

R&S

®

ZVB14 and R&S

®

ZVB20

> 16 dB

> 16 dB

> 14 dB

> 10 dB

> 12 dB

> 8 dB

10 MHz to 8 GHz above 8 GHz

+10 dBm

+5 dBm at –10 dBm without power calibration in temperature range +18 °C to +28 °C

10 MHz to 8 GHz < 1 dB above 8 GHz

(R&S

®

ZVB14 and R&S

®

ZVB20 only)

< 2 dB referenced to –10 dBm in temperature range +18 °C to +28 °C

R&S

®

ZVB4 and R&S

®

ZVB8 for +20 dB to –60 dB

50 MHz to 4 GHz < 0.1 dB

4 GHz to 6 GHz (R&S

®

ZVB8 only) < 0.1 dB

6 GHz to 8 GHz (R&S

®

ZVB8 only) < 0.2 dB for –60 dB to –130 dB

50 MHz to 4 GHz typ. < 0.1 dB

4 GHz to 6 GHz (R&S

®

ZVB8 only) typ. < 0.1 dB

6 GHz to 8 GHz (R&S

®

ZVB8 only) typ. < 0.2 dB

R&S

®

ZVB14 and R&S

®

ZVB20 for +20 dB to –30 dB

50 MHz to 700 MHz for –30 dB to –130 dB

50 MHz to 700 MHz for +20 dB to +10 dB

700 MHz to 8 GHz for +15 dB to +10 dB above 8 GHz for +10 dB to –45 dB above 700 MHz for –45 dB to –122 dB

< 0.1 dB typ. < 0.1 dB

< 0.3 dB

< 0.3 dB

< 0.1 dB

Damage level

Damage DC voltage

Noise level above 700 MHz at 10 Hz measurement bandwidth

R&S

®

ZVB4 and R&S

®

ZVB8

300 kHz to 100 MHz typ. < 0.1 dB

+27 dBm

30 V

< –70 dBm

100 MHz to 4 GHz < –110 dBm

4 GHz to 8 GHz (R&S

®

ZVB8 only) < –105 dBm

R&S

®

ZVB14 and R&S

®

ZVB20

100 MHz to 700 MHz

700 MHz to 8 GHz above 8 GHz

< –70 dBm

< –105 dBm

< –100 dBm

The noise level is defined as the RMS value of the indicated noise floor.

14 Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer

Version 08.02, June 2011

Additional front panel connectors

USB

(two) universal serial bus connectors for connecting USB devices (USB 1.1); two additional USB connectors at the rear panel

Display

Screen

Resolution

21 cm (8.4") diagonal color LCD

800 × 600 × 262144 (high color)

Rear panel connectors

IEC BUS

remote control in line with IEEE488, IEC60625; 24 pins

LAN 1

LAN 2

USB

first local area network connector, 8 pins, RJ-45 second local area network connector, 8 pins, RJ-45

(two) universal serial bus connectors for connecting USB devices (USB 1.1); two additional USB connectors at the front panel

10 MHz REF

Connector type

Input frequency

Maximum permissible deviation

Input power

Input impedance

Output frequency

Output frequency accuracy

Output power alternatively input or output for external frequency reference signal

DC MEAS 1 V

DC measurement input

Connector type

Voltage range

Measurement accuracy

Resolution

Bandwidth

Input impedance

Damage voltage

DC MEAS 10 V

DC measurement input

Connector type

Voltage range

Measurement accuracy

Resolution

Bandwidth

Input impedance

Damage voltage

BNC, female

10 MHz

1 kHz

–5 dBm to +10 dBm

50

Ω

10 MHz

80 Hz

–5 dBm to +10 dBm at 50

Ω

4-pin mini DIN, female

–1 V to +1 V

2.5 % of reading + 2.5 mV

< 100 kHz

> 10 k

Ω

30 V

4-pin mini DIN, female

–10 V to +10 V

2.5 % of reading + 25 mV

< 100 kHz

> 10 k

Ω

30 V

Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer 15

Version 08.02, June 2011

PORT BIAS

Connector type

Maximum nominal input voltage

Maximum nominal input current

Damage voltage

Damage current

DC bias input for PORT

BNC, female

30 V

200 mA

30 V

500 mA

MONITOR

IBM PC compatible VGA monitor connector, 15-pin D-Sub (for external monitor)

USER CONTROL

several control and trigger signals, 25-pin D-Sub, 3.3 V TTL for controlling external generators, for limit checks, sweep signals, etc.

FOOT SWITCH 1 and FOOT SWITCH 2 pin 24 and pin 25 (inputs) control inputs pin 16 to pin 19 (outputs) indicate driving port DRIVE PORT 1 to DRIVE PORT 4

CHANNEL BIT 0 to CHANNEL BIT 3

PASS 1 and PASS 2

BUSY

READY FOR TRIGGER

EXT GEN TRIGGER pin 13 and pin 14 (outputs) pin 4 (output) pin 6 (output) pin 21 (output) pass/fail results of limit checks measurements running ready for trigger control signal for external generator

EXT GEN BLANK

EXTERNAL TRIGGER pin 22 (input) pin 2 (input) handshake signal from external generator trigger input for analyzer

EXT TRIGGER

Connector type

TTL signal (edge-triggered)

Polarity (selectable)

Minimum pulse width

Input impedance trigger input for analyzer

BNC, female

3 V positive or negative

1 µs

> 10 k

Ω

16 Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer

Version 08.02, June 2011

Options

Generator step attenuators

Frequency range

Power range

Power accuracy

Power linearity

Match

Receiver linearity

Dynamic range

Direct generator/receiver access

Frequency range

Dynamic range

Power range

Match

Noise level extend the lower limit of the output power range of the R&S

®

ZVB4 or the R&S

®

ZVB8 by

70 dB

R&S

®

ZVB4

R&S

®

ZVB8

300 kHz to 4 GHz

300 kHz to 8 GHz upper limit is reduced by 8 dB, lower limit is extended by 70 dB at –10 dBm without power calibration above –30 dBm identical to specifications without optional step attenuators identical to specifications without optional step attenuators

–30 dBm to –70 dBm

–70 dBm to –100 dBm

< 2 dB

< 3 dB without system error correction

R&S

®

ZVB4

300 kHz to 2 GHz

2 GHz to 4 GHz

R&S

®

ZVB8

300 kHz to 2 GHz

2 GHz to 7 GHz

> 14 dB

> 16 dB

7 GHz to 8 GHz > 14 dB referenced to –10 dBm, in temperature range +18 °C to +28 °C for +13 dB (typ. +20 dB) to –60 dB

> 14 dB

> 16 dB

50 MHz to 4 GHz

4 GHz to 6 GHz

6 GHz to 8 GHz

< 0.1 dB

< 0.1 dB

< 0.2 dB is reduced by 8 dB

These options permit direct access to the internal source output as well as to the internal reference and measurement receiver inputs via the front panel connectors

(SMA) of the R&S

®

ZVB14 or the R&S

®

ZVB20.

R&S

®

ZVB14

R&S

®

ZVB20

R&S

®

ZVB14

10 MHz to 14 GHz

10 MHz to 20 GHz

10 MHz to 13 GHz

13 GHz to 14 GHz

R&S

®

ZVB20 is reduced by 2 dB is reduced by 4 dB

10 MHz to 13 GHz

13 GHz to 20 GHz

R&S

®

ZVB14

10 MHz to 13 GHz is reduced by 2 dB is reduced by 4 dB upper limit is reduced by 1 dB upper limit is reduced by 2 dB 13 GHz to 14 GHz

R&S

®

ZVB20

10 MHz to 13 GHz

13 GHz to 20 GHz

R&S

®

ZVB20

16 GHz to 20 GHz

R&S

®

ZVB14

10 MHz to 13 GHz

13 GHz to 14 GHz

R&S

®

ZVB20

10 MHz to 13 GHz

13 GHz to 20 GHz upper limit is reduced by 1 dB upper limit is reduced by 2 dB is reduced by 1 dB is increased by 1 dB is increased by 2 dB is increased by 1 dB is increased by 2 dB

Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer 17

Version 08.02, June 2011

General data

Temperature loading

Damp heat

Mechanical resistance

Calibration interval

EMC

Safety

Power supply

Power consumption

Conformity mark

Dimensions (W × H × D)

Weight

Shipping weight operating temperature range storage temperature range vibration, sinusoidal vibration, random shock

RF emission other emissions and immunity

R&S

®

ZVB4 and R&S

®

ZVB8

R&S

®

ZVB14 and R&S

®

ZVB20 with two ports and order numbers

1145.1010.14 and 11451010.20

R&S

®

ZVB14 and R&S

®

ZVB20 with two ports and order numbers

1145.1010.17 and 11451010.23, or with four ports

R&S

®

ZVB4 and R&S

®

ZVB8

R&S

®

ZVB14 and R&S

®

ZVB20 with two ports and order numbers

1145.1010.14 and 11451010.20

R&S

®

ZVB14 and R&S

®

ZVB20 with two ports and order numbers

1145.1010.17 and 11451010.23, or with four ports

R&S

®

ZVB4 and R&S

®

ZVB8

R&S

®

ZVB14 and R&S

®

ZVB20 with two ports and order numbers

1145.1010.14 and 11451010.20

R&S

®

ZVB14 and R&S

®

ZVB20 with two ports and order numbers

1145.1010.17 and 11451010.23, or with four ports

+5 °C to +40 °C

–40 °C to +70 °C in line with IEC 60068-2-1 and

IEC 60068-2-2

+40 °C at 95 % rel. humidity, in line with IEC 60068-2-30

5 Hz to 150 Hz, in line with IEC 60068-2-6

10 Hz to 300 Hz, in line with IEC 60068-2-64

40 g shock spectrum, in line with IEC 60068-2-27, MIL-STD-810

1 year in line with CISPR 11/EN 55011 group 1 class A for a shielded test setup in line with IEC/EN 61326, emission class B (residential environment), immunity industrial environment (excluding operating frequency) in line with IEC 61010-1, EN 61010-1 and

UL 3111-1

100 V to 240 V (AC) with tolerance ±10 %,

50 Hz to 60 Hz with tolerance ±5 %, safety class I in line with VDE 411

450 W, typ. 350 W (standby: typ. 10 W)

VDE, GS, CSA, CSA-NRTL/C, CE

465.1 mm × 241.8 mm × 417.0 mm

(18.31 in × 9.52 in × 16.42 in)

465.1 mm × 241.8 mm × 417.0 mm

(18.31 in × 9.52 in × 16.42 in)

465.1 mm × 286.2 mm × 417.0 mm

(18.31 in × 11.27 in × 16.42 in)

18 kg (40 lb)

16 kg (35 lb)

20 kg (44 lb)

29 kg (64 lb)

30 kg (66 lb)

32 kg (71 lb)

18 Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer

Version 08.02, June 2011

Ordering information

Vector Network Analyzer, 4 GHz, 2 ports

Vector Network Analyzer, 4 GHz, 4 ports

Vector Network Analyzer, 8 GHz, 2 ports

Vector Network Analyzer, 8 GHz, 4 ports

Vector Network Analyzer, 14 GHz, 2 ports

Vector Network Analyzer, 14 GHz, 2 ports

Vector Network Analyzer, 14 GHz, 4 ports

Vector Network Analyzer, 20 GHz, 2 ports

Vector Network Analyzer, 20 GHz, 2 ports

Vector Network Analyzer, 20 GHz, 4 ports

Options

Direct generator/receiver access

Direct Generator/Receiver Access for the R&S

®

ZVB14 1145.1010.17 only

Direct Generator/Receiver Access for the R&S

®

ZVB14 1145.1010.19 only

Direct Generator/Receiver Access for the R&S

®

ZVB20 1145.1010.23 only

Direct Generator/Receiver Access for the R&S

®

ZVB20 1145.1010.25 only

Generator step attenuators (for the R&S

®

ZVB4 and R&S

®

ZVB8 only)

Generator Step Attenuator for Port 1

Generator Step Attenuator for Port 2

Generator Step Attenuator for Port 3

Oven Quartz (OCXO)

Time Domain

Mixer and Harmonic Measurements

Service options

Two-Year Calibration Service

Three-Year Calibration Service

Five-Year Calibration Service

One-Year Repair Service following the warranty period

Two-Year Repair Service following the warranty period

Four-Year Repair Service following the warranty period

R&S

R&S

R&S

R&S

R&S

R&S

R&S

R&S

R&S

®

®

R&S

®

R&S

®

®

®

®

®

®

R&S

®

R&S

®

R&S

®

R&S

®

®

®

ZVB4 1145.1010.04

ZVB4 1145.1010.06

R&S

®

ZVB8 1145.1010.08

R&S

®

ZVB8 1145.1010.10

R&S

®

ZVB14 1145.1010.14

R&S

®

ZVB14 1145.1010.17

R&S

®

ZVB14 1145.1010.19

ZVB20 1145.1010.20

ZVB20 1145.1010.23

ZVB20 1145.1010.25

ZVB14-B16 1164.1240.17

ZVB14-B16 1164.1240.19

ZVB20-B16 1164.1240.23

ZVB20-B16 1164.1240.25

ZVB8-B21 1302.5480.02

ZVB8-B22 1302.5073.02

ZVB8-B23 1302.5496.02

ZVAB-B4 1164.1757.02

ZVAB-K2 1164.1657.02

ZVB-K3 1164.1592.02

R&S

®

CO2ZVB

R&S

®

CO3ZVB

R&S

®

CO5ZVB

R&S

®

RO2ZVB

R&S

®

RO3ZVB

R&S

®

RO5ZVB please contact your local

Rohde & Schwarz sales office

Rohde & Schwarz R&S

®

ZVB Vector Network Analyzer 19

Service you can rely on

J

Worldwide

J

Local and personalized

J

Customized and flexible

J

Uncompromising quality

J

Long-term dependability

About Rohde & Schwarz

Rohde & Schwarz is an independent group of companies specializing in electronics. It is a leading supplier of solutions in the fields of test and measurement, broadcasting, radiomonitoring and radiolocation, as well as secure communications. Established more than 75 years ago,

Rohde & Schwarz has a global presence and a dedicated service network in over 70 countries. Company headquarters are in Munich, Germany.

Environmental commitment

❙Energy-efficient products

❙Continuous improvement in environmental sustainability

❙ISO 14001-certified environmental management system

Certified Quality System

ISO 9001

Umschlag_ZVB.indd 2

Rohde & Schwarz GmbH & Co. KG

www.rohde-schwarz.com

Regional contact

❙Europe, Africa, Middle East

+49 89 4129 123 45 [email protected]

❙North America

1 888 TEST RSA (1 888 837 87 72) [email protected]

❙Latin America

+1 410 910 79 88 [email protected]

❙Asia/Pacific

+65 65 13 04 88 [email protected]

R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG

Trade names are trademarks of the owners | Printed in Germany (as)

PD 0758.1529.22 | Version 08.02 | June 2011 | R&S®ZVB