Catalogue Sheet: Invisilite Series
Type:
Project/Location:
Contractor:
Prepared By:
Date:
Model No.:
Made in Canada
TYPICAL SPECIFICATIONS
INVISILITE™ SERIES
100% Recessed
Emergency Lighting
FEATURES
• Door flips 180° when AC fails
• Fully automatic operation – brown-out
sensitive transfer circuit automatically
goes to emergency lighting mode and,
when the power is restored or at the end
of battery discharge, the motor turns the
door back to its original closed mode
• Customized finish – Off-white, but can be
painted or wallpapered on site to match
existing decor
• Heavy-duty back-box – made of heavy-duty,
galvanized steel
• High-performance lighting– includes two
MR16 halogen lamps; power range from
12W to 50W, LED up to 4W, 5W & 6W
• Patent-pending design
• Meets or exceeds CSA 22.2 No.141
Supply and install Ready-Lite® Invisilite™ Series. The unit shall be designed to be concealed in walls or
ceilings with a cavity, including T-bar suspended ceilings. Bar hanger brackets shall be provided with the
Self-Powered unit. The unit equipment shall come standard with a metal back box containing the batteries,
the lamp assembly and a charging circuitry. The back box shall be constructed of heavy-duty galvanized steel.
The unit components: battery assembly, charger circuitry and lamp assembly shall have a modular design
and come standard with quick-connect plugs for easy installation in the back box. The unit equipment shall
be completely concealed in the wall or ceiling during normal power conditions. Upon a power failure the unit
will expose the emergency heads by rotating its door 180° and then power the lamps. At the restoration of
the AC power or at the end of the battery discharge, the lamps will turn off and the unit will retract the heads
in the wall (ceiling) by rotating the door by 180°. Under normal conditions, the only visible parts of the unit
shall be the flat door and trim plate, coated with a high-quality off-white finish that can be customized on site
with paint or other suitable wall covering. The light source shall be 12V MR16 halogen lamps of specified
wattage and light output.
The unit shall supply the rated load for a minimum of 30 minutes or until the battery is discharged to 87 ½%
of its nominal voltage (whichever duration is longer). The charger circuitry shall utilize a micro-controller IC that
samples the battery in relation to the ambient temperature, state of charge, and input voltage fluctuations. The
charger shall be current limited, temperature compensated, short-circuit proof, and reverse-polarity protected.
The circuit will charge in accordance with CSA C22.2 – 141 requirements. The unit shall be furnished with a
recessed, illuminated push button serving as test switch and status indicator light. When specified, the unit
shall come complete with Ready-Lite® auto-test micro-controller circuitry to ensure the equipment readiness
and reliability by continuously monitoring every critical function of the unit. If a problem occurs, the pilot light
located on the front of the unit will change colour from green to red and will flash indicating a fault. A detailed
diagnostic legend shall be available on the door back side and shall provide fault identification (battery, charger
circuitry, lamps) for maintenance personnel.The auto-test shall simulate a power loss for one minute monthly,
10 minutes every 6 months, and a full 30-minute test every 12 months.
The equipment shall be Ready-Lite® model:
.
POWER CONSUMPTION
MODEL
AC ASPECS
HIDE75
120/347VAC
HIDE150
30MIN
0.25/0.09 A
DIMENSIONS
Dimensions are approximate and subject to change.
7” [17.8 cm]
23-7/8” [60.6 cm]
3-3/8” [8.6 cm]
9-1/8” [23.2 cm]
7-7/8” [20.0 cm]
WATTAGE CAPACITY
1H00
1H30
2H00
4H00
75
40
30
24
15
150
80
60
48
30
REPLACEMENT LAMPS: MR16 TYPE
MODEL
LAMP TYPE
VOLTAGE/
WATTAGE
580.0080-RL
MR16 halogen
12V-12W
580.0064-RL
MR16 halogen
12V-20W
580.0083-RL
MR16 halogen
12V-35W
580.0076-RL
MR16 halogen
12V-50W
580.0068-RL
MR16 high-lumen output
12V-20W H
580.0090-RL
MR16 high-lumen output
12V-35W H
580.0089-RL
MR16 high-lumen output
12V-50W H
580.0093-RL
MR16, LED
12V-4W
580.0104-RL
MR16, LED
12V-5W
580.0106-RL
MR16, LED
12V-6W
ORDERING INFORMATION
SERIES
HIDE
UNIT CAPACITY
75= 12V-75W
lead-acid
150= 12V-150W
lead-acid
LAMP WATTAGE (12V)
LD7= MR16 LED, 2X 4W
LD9= MR16 LED, 2X 5W
LD10= MR16 LED, 2X 6W
12W= MR16 halogen, 2X 12W
20W= MR16 halogen, 2X 20W MR16
35W= MR16 halogen, 2X 35W MR16
50W= MR16 halogen, 2X 50W MR16
20WH= MR16, 2X 20W high lumen output lamp
35WH= MR16, 2X 35W MR16, high lumen output lamp
50WH= MR16, 2X 50W MR16,high lumen output lamp
EXAMPLE: HIDE7512WAD
104
OPTIONS
AD= auto-diagnostics*
ADN= auto-diagnostics, non-audible*
D3= time delay (15 mins.)
*Minimum lamp load required: 20% of unit
capacity
AC VOLTAGE
Blank= 120/347VAC
U277= 120/277VAC