3-Phase Voltage Monitor Model 201-XXX-DPDT Features: • • • • • • • • • • • Low voltage protection Single-phase protection Reverse-phase protection Voltage unbalance protection Two isolated Form C relays (DPDT) Diagnostic LED UL508 Listed CE Marked 11-pin plug in; DIN rail or surface mount 5-year warranty Made in the USA The 201-XXX-DPDT is an 11-pin octal base plug-in voltage monitor designed to protect 3-phase motors regardless of size. The 201100-DPDT is used on 95-120VAC, 50/60Hz motors and the 201200-DPDT is used on 190-240VAC, 50/60Hz motors to prevent damage caused by incoming voltage problems. The units feature two isolated sets of contacts that are ideal for use with two control circuits with different voltages. The unique microcontroller-based voltage and phase-sensing circuit constantly monitors the voltages to detect harmful power line conditions. When a harmful condition is detected, the MotorSaver’s output relays are deactivated after a specified trip delay. The output relays reactivate after power line conditions return to an acceptable level and a specified amount of time has elapsed (restart delay). The trip delay prevents nuisance tripping due to rapidly fluctuating power line conditions. This unit is also available with a shorter trip delay and faster restart delay. The 201-XXX-DPDT-60mS has a trip delay of 0.5 seconds and a restart delay of 60 milliseconds. See the specification table for details. (605) 348.5580 / (800) 843.8848 / Fax (605) 348.5685 [email protected] / [email protected] Rev. 0809 Specifications Functional Characteristics Enclosure Dimensions 90% +1% 93% +1% 3 6% 4.5% 4 2 5 1 6 11 4 seconds 2 seconds 0.5 second 1.75” (44.55) 9 8 10 7 Adjustments/Settings Low Voltage (% of setpoint) Trip Reset Voltage Unbalance Trip Reset Trip Delay Times Low voltage Unbalanced voltage and single-phasing faults (>15%UB) Models with -60mS option Restart Delay Times After a fault After a complete power loss Models with -60mS option 2 seconds 2 seconds 60 milliseconds Input Characteristics 2.375” (60.331) Supply Voltage 201-100-DPDT 201-200-DPDT Frequency 95-120VAC 190-240VAC 50/60 Hz (note: 50Hz will increase all delay timers by 20%) BOTTOM Output Characteristics Output Contact Rating - DPDT Pilot Duty General Purpose 480VA @ 240VAC 10A @ 240VAC General Characteristics Operating Temperature (Surrounding Air) Maximum Input Power Relative Humidity Terminal Torque Wire Gauge Standards Passed Electrostatic Discharge (ESD) Models with -60mS option Radio Frequency Immunity (RFI), Radiated Fast Transient Burst Models with -60mS option Surge Immunity IEC ANSI/IEEE Hi-potential Test Safety Marks UL listed (OT11 octal socket required) CE Dimensions Weight Mounting Method How to order: Part Number: -40o to 70o C (-40o to 158o F) 5W 10-95%, non-condensing per IEC 68-2-3 12 in.-lbs. 12-22 AWG Solid or stranded 4.125” (104.65) IEC 61000-4-2, Level 3, 6kV contact, 8kV air IEC 61000-4-2, 3kV contact, 6kV air 150MHz, 10V/m IEC 61000-4-4, Level 3, 3.5 kV input power and controls IEC 61000-4-4, Level 3, 2.5kV input power and controls IEC 61000-4-5, Level 3, 4kV line-to-line; Level 4, 4kV line-toground C62.41 Surge and Ring Wave Compliance to a level of 6kV line-to-line Meets UL508 (2 x rated V + 1000V for 1 minute) UL508 (File #E68520) IEC 60947-6-2 2.330”H x 2.375”W x 4.125”D (with socket) 1.2 lbs. Plugs into 11-Pin OT11 Socket (DIN rail or surface mount) 201-100-DPDT 201-200-DPDT 201-100-DPDT-60mS 201-200-DPDT-60mS SIDE WITH OT11* SOCKET Auxiliary Products: OT11-PC (11-pin octal socket) (605) 348.5580 / (800) 843.8848 / Fax (605) 348.5685 [email protected] / [email protected] Rev. 0809
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement