Description:
The Bettis hand pump can be used together with all standard actuators such as BHH, BHHF, BL
and BLF. Overall there exists a hand pump for single line actuators and for double line actuators.
Depending on actuator size, control type and valve location these two hand pump types can be
applied in different variants for emergency operation and standalone operation without other
remote facilities.
Further information can be found in the data sheet for the direct mounted hand pump and the
remote mounted hand pump.
Hand pump program:
Hand pump:
HP:Hand pump
Bulkhead type:
B-VPI: Remote mounted with VPI-V
Actuator type:
S: For single line actuator
D: For double line actuator
Tank size:
- : No tank
50: 50 ml closed tank
1: 1 L open tank
4: 4 L open tank
Application:
-: Direct mounted
B: Bulkhead mounted
Examples:
Submerged valves - HP-S-B-VPI-V-4
- Hand pump
- For single line actuator
- Bulkhead mounted with VPI-V
- 4 L open tank
Shipside valves - HP-D-1
- Hand pump
- For double line actuator
- Direct mounted
- 1 L open tank
Main data:
www.Bettis.com
Other additional: Quick connection
Mounting: Prepared for actuator and remote mount block interface
A and B connection: 1/4” BSPP
Maximum operation pressure: 135 bar (1958 PSi)
Test pressure: 210 bar (3045 PSi)
Maximum hand pump pressure:
135 bar (1958 PSi)
Weight without oil:
0 L tank: 5.3 kg, 50 ml tank: 6 kg
1 L tank: 9 kg and 4 L tank: 15 kg
Oil displacement per double stroke: 6 cm3 (.37 in3)
Oil viscosity range:
From 15 to 200 cSt
Temperature range: From -25˚C to 80˚C (-13˚F to 176˚F)
Recommended oil filtration: ISO Solid Contaminant Code 18/15 or NAS 160/10
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Data sheet
HPG01
Sheet No.: HPG01.02 RevA
Date: October 2010
Material:
Housing / Cover: Brass
Spindle / Piston: Aluminum bronze
Valves: Brass
Screws / Sign plate / Rivet: Stainless steel
Sealings: NBR (Acrylonitrile butadiene)
General installation requirements:
General installation requirements:
-
To gain maximum hand pump performance it is of significant importance that the
pipes between hand pump and actuator are well de-aired.
-
Distance between hand pump and actuator must not exceed 50 m. (164 ft.)
In case of solenoid valve is needed for remote indirect indication:
-
4/3 ways SC solenoid throttle valve for double line actuators.
-
4/2 ways SR (FC / FO) solenoid valve on/off for single line actuators.
Specific rules related to hand pump applications can be found in the direct mounted and remote
mounted handpump datasheet.
www.Bettis.com
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Data sheet
HPG01
Sheet No.: HPG01.03 RevA
Date: October 2010
Emergency operation for single line actuator:
Description of the hand pump emergency operation can be found on the instruction plate
mounted on the hand pump. The emergency description for the single actuators is as follows:
Emergency opening:
-
-
Close stop valve (1).
Operate hand pump to open actuator.
Emergency closing:
-
-
Open stop valve (2).
When actuator is closed,
- Close stop valve (2)
- Open stop valve (1)
Notice:
Remote operation will not reset opening; if emergency opened the actuator has to be emergency
closed again.
www.Bettis.com
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Data sheet
HPG01
Sheet No.: HPG01.04 RevA
Date: October 2010
Emergency operation for double line actuator:
Description of the hand pump emergency operation can be found on the instruction plate
mounted on the hand pump. The emergency description for the double line actuators is as
follows:
www.Bettis.com
Emergency opening:
Emergency closing:
- Turn directional valve to “OPEN”.
- Turn directional valve to “CLOSE”.
- Operate hand pump.
- Operate hand pump.
The valve will now stay in position until
The valve will now stay in position until
operated with hand pump again or by remote
operated with hand pump again or by remote
control.
control.
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Data sheet
HPG01
Sheet No.: HPG01.05 RevA
Date: October 2010
Enclosure rating:
When mounted in block, cavity seals are designed to fulfill demands of enclosure rating IP 68.
Note: In case of installation where a larger enclosure rating than IP 67 is required, the connection
house should be filled with silicone after wire mounting and test of function. With each actuator
comes a yoke, fit to transfer the mechanical signal from the actuator to the DPI.
Potentiometer:
The potentiometer incorporated in the DPI-C is a high quality potentiometer that is extremely
reliable as long as the following ratings are observed:
Max. continuous load:
Max. peak load:
The normal output range is at
1 kΩ:
2 kΩ:
10 kΩ:
0.12 W (VA)
1 W(VA)
0-500 Ω for 0-90° rotation*
300-1400 Ω for 0-90° rotation*
1500-7000 Ω for 0-90° rotation*
*Approx. adjustment for open (1400/7000) and close (300/1500) set point.
Analogue signal processing:
LPU is equipped with signal conditioning,with a 2-wire 4 - 20 mA signal output. When DPI-C is
block mounted we recommend the Bettis isolation amplifier 2204 for transforming the resistance
signal into a standard 4-20 mA signal. The output can be displayed visually by means of the Bettis
meter PQ 48 measuring 48 x 48 mm and scaled:“closed, 1/4, 1/2, 3/4, open”.
Materials:
Housing: Screws: Seals: Fixture: Brass, MS 58 (CuZn39Pb3)
AISI 304 (Stainless)
NBR ~ Acrylonitrile Butadiene
PPS
Cable gland data:
Cable outer diameter: Ingress protection: Thread: Material: Seal material: ø 6-10.5 or ø 8-15 mm (.24-.39 or .31 - .59 in)
IP 68
M 16 or M 20
Nickel plated brass
Perbunan and NBR (Rubber)
Cable quality/connection:
Wiring to the terminal: Cross sections 0.5-1.5 mm2 (AWG 22 - 16).
Observe that water intrusion into the terminal housing can take place through the cable - even through
each individual wire. The IP tightness is based on correct and careful mounting.
Note: Not Certified dimensional drawings. Such drawings are available on request. Contact factory with correct model designation and serial number.
Important: Due to Emerson’s continuing commitment to engineered product advancement, data presented herin is subject to change.
The contents of the publication are presented for information purposes only, and while effort has been made to ensure their accuracy,
they are not to be construed as warranties or guarantees, expresses or implied, regarding the products or services described herein or their use or applicability.
All sales are governed by our terms and conditions, which are available on request.
We reserve the right to modify or improve the designs or specifications of our products at any time without notice.
www.Bettis.com
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement