Introduction
5240IG
Thermotouch 4.3iC® thermostat
®
Thermotouch 4.3iC® is a digital thermostat, which is designed for electric floor
heating systems with a maximum load of up to 16A (3600W). Thermotouch
4.3iC® features a 4.3” Intelligent Control Truetouch colour display and 4
languages.
! IMPORTANT SAFETY REGULATIONS !
All wiring must conform to IEE 17th Edition Part P
regulations. This product is rated:
ip30
Thermotouch 4.3iC® is IP30 rated and suitable for safe installation in
bathrooms outside of special locations such as wet zones. All electrical
circuits in bathrooms must be protected by a 30mA RCD. The instructions
we supply include as much information as possible to ensure that all
installations comply with current electrical regulations. Please call our
freephone customer care line if in any doubt on 0800 019 5899.
2
DO
DO NOT
Install a conduit for your sensor
Ignore electrical regulations.
probe before thermostat installation.
Install this thermostat in a wet zone.
www.thermogroupuk.com
®
Installing Thermotouch 4.3iC®
5240IG
Before you begin
A sensor conduit and deep back box must be installed to continue this
installation. Feed the provided sensor probe (3m) down through the sensor
conduit into a representive area of the floor. For any technical advice or
questions visit our website, www.thermogroupuk.com or call our technical
team on 0800 019 5899.
Installation
Step 1: Release the face plate
Push the three clips located on the bottom of Thermotouch 4.3iC® in with a
screwdriver, releasing the face plate.
Step 2: Disconnect ribbon cable & remove face plate
Once the face plate has been gently opened disconnect the ribbon cable to
release the face plate.
freephone 0800 019 5899
3
Wiring Thermotouch 4.3iC®
5240IG
Wire and replace face plate
Loosen the tension
screws to allow the
wires to be inserted
and fixed. Position the
cables as shown in the
wiring diagram and
ensure each screw is
tightened correctly.
7
6
5
4
3
2
1
L
N
N
L
3600W/16A
Sensor
230V/AC
Ensure system is correctly earthed.
Fix Thermotouch 4.3iC® to wall
Align Thermotouch
4.3iC® with your
back box and fix in
place with the screws
provided.
Now reconnect the
ribbon connections and
reseat the face plate
(bottom edge first).
Ensure Thermotouch
4.3iC® is securely fixed
before continuing.
4
2
1
3
4
5
2
1 Faceplate
4 Back plate
2 Provided screws
5 Back box
3 Ribbon connectors
www.thermogroupuk.com
Programming Thermotouch 4.3iC®
5240IG
Thermotouch 4.3iC® interface
10
9
8
7
6
11
5
12
4
13
14
3
1
2
3
4
5
6
7
On / Off button
Mode button
Menu button
Down button
Up button
Mode icon
Set temperature
2
8
9
10
11
12
13
14
freephone 0800 019 5899
1
Heating icon
Weekday icon
Ambient temperature
Clock icon
Temperature icon
Floor temperature
Mode icon area
5
Programming Thermotouch 4.3iC®
5240IG
Mode icon key
Menu
6
Mode
Language selection
Press to choose one of
four languages
Holiday mode
Once selected, enables
‘Holiday mode’
Pre-set temperatures
Use to define pre-set
temperatures
Boost mode
Once selected, enables
‘Boost mode’
Program review
Use to check your
5+1+1 day schedule
Economy mode
Once selected, enables
‘Economy mode’
Date & time Button
Use to set the correct
weekday and time
Program mode
Once selected, enables
your custom schedule
Protection temperatures
Use to define min and
max temperatures
Comfort mode
Once selected, enables
‘Comfort mode’
www.thermogroupuk.com
Programming Thermotouch 4.3iC®
5240IG
Schedule settings
Press Menu Button, then press
review your weekly schedule.
to
Select Mon - Fri, Sat or Sun to edit
your custom heating schedule.
Example: if you want to edit Sun
schedule, press Sun column to enter
the edit page as shown.
Every setting can be edited with the
or
buttons.
1
1.
2.
2
3
3.
In the Sun column, there are six periods. You can press
or
buttons to choose the period you are going to change.
will display
next to which ever period is selected.
Next you can set the start time and desired temperature by pressing
the
and
buttons.
Press APPLY to save your new schedule.
freephone 0800 019 5899
7
Programming Thermotouch 4.3iC®
Edit time & date
Press MENU button, then
button
to edit date and time with
and
buttons. Press APPLY to save the
changes.
Mode pre-set temp.
button to
Press Menu button, then
select a mode. Now edit that modes
temperature with
and
buttons.
Press APPLY to save the changes.
Language select
Press Menu button, then
button
to enter languages page. Choose the
desired language and press APPLY to
save the changes.
8
www.thermogroupuk.com
5240IG
Programming Thermotouch 4.3iC®
5240IG
Protection settings
Press Menu then
button to enter
protection settings page. You can set
Over Protection temperature & Low
Protection temperature with the
and
buttons. Press APPLY to save the
changes.
High protection: This is an Over Heat Protection setting designed to monitor
the floor temperature and limit it to a level set by you. If the system reaches
the set protection temperature the system will shut off automatically.
Low protection: This is a frost protection mode designed to function when
Thermotouch 4.3iC® is switched off. If the ambient temperature reaches
the set protection temperature the system will automatically switch on to
maintain a minimum temperature.
Please note: The upper limit should be no higher than 280C to conform with
European regulations.
freephone 0800 019 5899
9
Programming Thermotouch 4.3iC®
5240IG
Parameter settings
To access parameter settings switch Thermotouch 4.3iC® OFF and
immediately press
for 2 seconds. You can set the desired values by
pressing << or >> , and go to other pages by pressing Pre or Next.
Please note the upper limit should be no higher than 280C to conform with
European regulations.
Menu
Description
Range
01
Temp. Offset
-8 0C ~80C
02
Dead Zone
00C ~30C
03
Set Point Max.
5 0C ~350C
04
Set Point Min.
5 0C ~350C
05
NTC Select (Ambient - I, Floor - E)
I only, E only, I & E, I or E
06
Low Protection Max.
5 0C ~100C
07
Low Protection Min.
5 0C ~100C
08
High Protection Max.
5 0C ~900C
09
High Protection Min.
5 0C ~900C
10
Backlight off Time after Operation.
3s~180s
11
Min. Backlight Brightness of Standby Status
1%~100%
12
Relay Delay Time
0s~250s
13
Relay Output
Normal(NO);Inverted(NC)
14
Restore
<< or >>
10
www.thermogroupuk.com
Technical specification
5240IG
Dimensions
60mm
19mm
31mm
50mm
52mm
L
3600W/16A
N
N
2
3
230V/AC
L
Sensor
7
6
5
4
94mm
87mm
4.3”
130mm
freephone 0800 019 5899
11
1
Technical specification
5240IG
Product features
•
•
•
•
•
•
•
•
•
•
4.3inch Truetouch colour display
Control electric underfloor heating systems up to 16A (3600W)
Adjustable Comfort Mode, Economy Mode, Boost Mode, Holiday Mode
and Program Mode Control
5+1+1 days, 6 event programmable schedule
Ambient and/or floor sensors
Four languages: English, French, Germany, Dutch
Clock and date display
Temperature calibration
Overheat and frost protection modes
Single gang extra deep back box
Product features
•
•
•
•
•
•
E&OE
12
Voltage: 230V, 50/60Hz
Maximum load: 16A (3600W)
Temperature range: 5~350C
Ambient: 0~500C
Sensor: NTC10k, 10kΩ at 250C
Accuracy: ± 0.50C
©Thermogroup UK 2013
0800 019 5899
Thermogroup UK,
Bridge House,
Hop Pocket Lane,
Paddock Wood,
Kent. TN12 6DQ
www.thermogroupuk.com
sales@thermogroupuk.com
0800 019 5899
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising