Estateâ„¢ Series Lennox

Estateâ„¢ Series Lennox
LENNOX™ ESTATE™ SERIES WOOD BURNING FIREPLACES • EST-36 / EST-42 / EST-50
Appliance Specifications
15" O.D.
(381 mm)
F
Q
H
K
Note: Outside air kit
installs on LEFT side
for EST-36 & EST-42.
G
G
P
A
J
Note: Outside air kit
installs on RIGHT
side for EST-50.
L
L
N
M
R
M
Left Side
Front View
Model No.
D
EST-36
& EST-42
E
B
Top View
Right Side
A
B
C
D
in. 42-9/16 47-7/8 28-9/16 37-1/4
mm
1081
1216
725
946
in.
mm
53-1/4
1353
EST-36
& EST-42
in.
mm
29
737
EST-50
in.
mm
36
914
EST-50
C
F
Model No.
59-1/2
1511
J
29-5/8
753
K
E
11
279
G
47-1/8
1197
H
36 / 42
914 / 1067
84
2134
61-7/8
1572
50
1270
44-5/8 14-1/4
1133
362
L
6 (36”) / 3 (42”) 10-1/2
152 (36”) / 76 (42”) 267
4-3/4
121
F
66-1/16
1678
15
381
M
N
P
Q
R
8-3/4
222
13
330
12
305
6-9/16
167
7
178
10
254
10-5/8
270
11-1/8
283
8-9/16
218
8-1/2
216
FIREPLACE FINISHES:
Mantels and Trim
FIREPLACE FINISHES:
Vertical Surround Limitations
FIREPLACE FINISHES:
Hearth Extensions and Wall Shields
In installations other than Canada, combustible mantels
and trim may be installed as shown in the illustrations
below and as per NFPA 211-Mantel/Trim Clearances. If a
mantel is of a noncombustible material, it is exempt from
these requirements as long as it does NOT interfere with
the installation or operation of glass doors.
For combustible mantel and trim specifications in
Canadian installations (EST-36 and EST-42 only), see
the fireplace Installation Instructions.
Combustible materials may project beyond the sides
of the fireplace opening as long as they are kept
within the shaded area illustrated below.
A hearth extension must be installed with all
fireplaces. Its purpose is twofold: 1) to protect a
combustible floor in front of the fireplace from
both radiant heat and sparks; and 2) to distinguish
the prescribed hearth extension area from other
unprotected surfaces.
12"
(305mm)
Max.
Finished
Wall
1-1/2 " (38mm)
Combustible
Mantel
and Trim
12"
(305mm)
Min.
Noncombustible
Wall Covering
Spacer
Combustible
materials allowed
in shaded Areas
Fireplace
3-1/4"
(83mm)
4-3/4"
(121mm)
40"
(1016mm)
Wall shield
required if
less than
18" (457mm).
1/2"
(13mm)
15°
12" (305mm)
Min. Distance to
Protected Side Wall
40"
(1016mm)
C
18" (457mm)
Min. Distance to
Unprotected Side Wall
B
C
A
EST-36 & EST-42:
6-9/16" (167mm)
EST-50:
10" (254mm)
Fireplace
Opening
Typical U.S. Installation
Note:
• Diagrams, illustrations, and photographs are
not to scale; consult fireplace Installation
Instructions.
• Product designs, materials, dimensions,
specifications, colors, and prices are subject
to change or discontinuance without notice.
• EST-50 models are not sold in Canada.
C
B
C
A
D
Models
EST-36
EST-42
EST-50
A
B
C
D
20"
36"
12"
60"
(508mm) (914mm) (305mm) (1524mm)
20"
42"
12"
60"
(508mm) (1066mm) (305mm) (1524mm)
20"
50"
12"
74"
(508mm) (1270mm) (305mm) (1880mm)
Hearth Extension Dimensions
Page 1 of 2
P/N 506035-35 Rev. A 03/2011
LENNOX™ ESTATE™ SERIES WOOD BURNING FIREPLACES • EST-36 / EST-42 / EST-50
Framing Specifications
Note: All framing dimensions calculated for 1/2 inch dry wall at the appliance face.
If sheathing the chase or finishing with other thickness materials, calculations will need to be made.
Insulate Joists
Same as Ceiling
FOAK-4
Air Kit
Back Wall of Chase/Enclosure
Including Finishing Materials
if any
Back Wall of Chase/Enclosure
Including Finishing Materials
if any
FOAK-4
Air Kit
G
G
J
Draft Stops
A
A
Rough Framing Face
(Unfinished Shown)
F10FS-2 Firestop
Rough Framing Face
(Unfinished Shown)
Outside Chase
Back Wall of Chase/Enclosure
Including Finishing Materials if any
FTF10-CTDTM
Termination
Note: NonCombustible
Chase
Flashing
Must be
Used to
Cover
Chase
Opening
FOAK-4
D
K
F
G
C
A
E
Optional
Insulation
in Outside
Walls of
Chase
8’
(2.4m)
Level
Solid
Continuous
Surface
Outside
Base
Insulation
(Thermal Barrier)
Typical Installation
Corner Installation
A
B1
B2
C
D
E
F
G
J
K
Rough
Framing Face
(Unfinished Shown)
Inside Chase
Note:
• The framed depth from a framed wall
(item “G” in the Framing Dimensions
table below) must always be measured
from a finished surface. If a wall
covering (such as drywall) is to be
attached to the rear wall, measure the
framed depth from the drywall surface.
This dimension MUST be exact.
• If the appliance is to be elevated
above floor level, a solid, continuous,
platform must be constructed.
• The header may rest on the top metal
Framing Dimensions
spacers; however, NEVER notch the
EST-36 and EST-42
EST-50
header to fit around the spacers.
48 in
(1219 mm) 60-3/4 in (1543 mm)
•
Consult all local codes.
47-1/4 in
(1200 mm) 62-1/4 in (1581 mm)
66-1/2 in
(1689 mm) 84-1/2 in
(2146 mm)
37-1/4 in
(946 mm)
44-5/8 in
(1133 mm)
18-5/8 in
(473 mm)
22-5/16 in (567 mm)
94-7/8 in
(2410 mm) 104-1/8 in (2645 mm)
47-7/16 in (1205 mm) 52-1/16 in (1322 mm)
28-13/16 in (732 mm)
29-3/4 in
(756 mm)
11-3/8 in
(289 mm)
10 in
(254 mm)
67 in
(1702 mm) 73-5/8 in
(1870 mm)
Header
B
False Header
A
D
C
Pitch
0/12
C
19"
(483 mm)
D*
19"
(483 mm)
6/12
19"
(483 mm)
19"
(483 mm)
22"
(559 mm)
27"
(686 mm)
12/12
Flue Type
A
B
FTF10 & 13
Vertical
19"
19"
(483 mm) (483 mm)
FTF10 & 13
30° Offset
19"
29"
(483 mm) (737 mm)
Ceiling Framing
B2
B1
A
Fireplace Framing
Roof Framing
*Perpendicular to roof ridge
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 2 of 2
P/N 506035-35 Rev. A 03/2011