S Sp pe

S Sp pe
Specification for Approval
12vdc 2A power supply with Fixed UK mains lead & Lugs
Customer
:
Part Name
Description
:
Model No.
P/ N
Product P / N
Issued Date
Version
:
Issued Stamp
:
:
:
:
:
:
AC ADAPTER
12Volts / 2Amps
STD-12020BT (Level V)
SW3114LUG
RXTD12020BT415202
25-Apr.-2011
A1
Customer’s Approval Signature
24W
Switching Power Adapter
SPECIFICATION
Model No.
:
STD-12020BT(Level V)
Description
:
12Volts / 2Amps
Part No.
:
RXTD12020BT415202
Version
:
A1
Date
:
25-Apr.-2011
Approved
Checked
Prepared
Approval Documents/Spec. Revised Records
■
■
■
Customer :
Model No. : STD-12020BT
Original Documents Content : Spec. 11 Pages, Attachment
Revised
Date
Records :
(mm/dd/yyyy)
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
04/25/2011
Description
( Before / After )
ISSUE
3
Pages
Page(s)
Revised By
Remark
Revised (Adapter/Customer)
-
Wei
A1
1. Feature:
♦
Input
: Universal 100 ~ 240 Vac / 47 ~ 63 Hz Input, without any slide switch.
♦
Output
: +12V / 0~2 A
♦
Case Dimension
: 115mm(L)*49.5mm(W)*30.6mm(H) (±0.5mm)
♦
Efficiency
: Eff (av) ≧ 82.22 % Min.
♦
Safety
:
♦
EMI
: CE Class B ; Conduction & Radiation Met.
Protection
:
♦
OVP (Over Voltage Protection)、SCP (Short Circuit Protection)、
OCP (Over Current Protection)
High frequency design,less power consumption.
♦
Suitable for usage at Telecommunication, Computer, Industrial Controller, & OA System.
♦
Meet Energy Star V / Erp ( Stage 2 ) / MEPS V .
♦
2. Input:
2.1 Voltage
Universal 100~240Vac, single phase
2.2
47 ~ 63 Hz
Frequency
2.3 Current
0.58A Max.
30A Max. / 100Vac ; 60A Max. / 230Vac
(Cold Start At 25 ºC,Full Load)
2.4 Inrush Current
2.5
Efficiency
Eff (av) ≧ 82.22% Min. (At 115 Vac & 230 Vac)
2.6
Power Consumption
Pi ≦ 0.3 W ( At 230Vac & No Load)
※Eff (av) =
E1 + E2 + E3 + E4
E1=efficiency with 25% rated load ; E2= efficiency with 50% rated load
4
E3=efficiency with 75% rated load ; E4= efficiency with 100% rated load
3. Output:
3.1
DC Output
Voltage
+12V ± 5%
Current
2.0A Max.
Regulation
11.4Vmin. ~ 12.0Vtyp. ~ 12.6Vmax.
Ripple & Noise
100 mV Max.
Total Power
24W Max.
Remark : For ripple & noise measurement, use a 20MHz bandwidth frequency oscilloscope, and add a 0.1μF multilayer Cap. and a
Low ESR Electrolytic Cap. (10 μF ) at output connector terminals. (At nominal line voltage, Full Load)
4. Protection :
4.1 Over Voltage Protection (OVP)
15V ( Max. )
4.2 Short Circuit Protection (SCP)
Automatic recovery after short-circuit fault being removed
4.3 Over Current Protection(OCP)
4A (MAX)
Remark : When Short Circuit Protection is activated,the power supply will shutdown automatically.
Once the abnormal condition resulting in the failure being removed, the power supply will restart accordingly. When
Over Voltage Protection is activated, the power supply will shutdown.
5. Safety、EMI and EMC Requirement:
5.1 Safety Requirement
a. Safety
:
b. Dielectric Strength
: 10mA Max. Cut off current
(1)
Primary to Secondary
c. Insulation Resistance
(1)
3000Vac
for 1 Minute
:
Primary to Secondary
10 M Ohm for 500Vdc
5.2 EMI Requirement
: CE Class B ; Conduction & Radiation Met.
5.3 Leakage Current
: Less than 0.25mA
6. Operation and Environment Performance:
6.1 Temperature Range
Operating
+ 0ºC
~
+ 40ºC
Storage
- 20 ºC
~
+ 80 ºC
6.2 Humidity Range(Non-condensing)
Operating
20%
~
80% RH
Storage
10%
~
90% RH
6.3 Cooling:By natural air
7. M.T.B.F.:50,000 Hrs. ( At 25ºC,By MIL-HDBK-217F )
8.Mechanical :
8.1
Weight : 165 g
Typical
8.2
Cable Type : Black
UL2468
AWG20
Output Cable Plug Pin Assignment
( Wire + Plug )
Plug : ø5.5*ø2.1*12mm
( Tuning Fork & Cannelure )
8.3
Cable Length : 1500mm
8.4
Case Dimension : 115mm(L)*49.5mm(W)*30.6mm(H) (±0.5mm)
8.5
Material
Flammability : UL 94V-0
8.6
External
Apperance : As drawing below ( Scale - mm )
A. Line Regulation Test
Test Result :
Test condition
Spec.
Reading 1
Reading 2
Reading 3
90Vac / 50 % Load
11.4~12.6 V
11.949 V
11.948 V
11.950 V
115Vac
/ 50 % Load
11.4~12.6 V
11.950 V
11.949 V
11.951 V
132Vac
/ 50 % Load
11.4~12.6 V
11.950 V
11.949 V
11.951 V
180Vac
/ 50 % Load
11.4~12.6 V
11.950 V
11.947 V
11.950 V
230Vac
/ 50 % Load
11.4~12.6 V
11.950 V
11.949 V
11.949 V
264Vac
/ 50 % Load
11.4~12.6 V
11.950 V
11.949 V
11.950 V
Test condition
Spec.
Reading 1
Reading 2
Reading 3
115Vac
82.22 % Min..
83.25 %
83.11 %
82.98 %
230Vac
82.22 % Min..
82.44 %
82.43 %
82.33 %
B. Efficiency Test
Test Result :
E1 + E2 + E3 + E4
Eff (av) =
4
E1=efficiency with 25% rated load ; E2= efficiency with 50% rated load
E3=efficiency with 75% rated load ; E4= efficiency with 100% rated load
C. Load Regulation Test
Test Result :
Test condition
Spec.
Reading 1
Reading 2
Reading 3
115Vac
/
0 % Load
11.4~12.6 V
12.075 V
12.073 V
12.074 V
115Vac
/ 50 % Load
11.4~12.6 V
11.950 V
11.948 V
11.949 V
115Vac
/ 100 % Load
11.4~12.6 V
11.824 V
11.825 V
11.822 V
230Vac
/
0 % Load
11.4~12.6 V
12.075 V
12.077V
12.073 V
230Vac
/ 50 % Load
11.4~12.6 V
11.950 V
11.952V
11.948 V
230Vac / 100 % Load
11.4~12.6 V
11.824 V
11.822 V
11.822 V
Spec.
Reading 1
Reading 2
Reading 3
D. Ripple & Noise Test
Test Result :
Test condition
115Vac
/
100 % Load
100mVpp Max
56.7mVpp
55.4mVpp
55.1mVpp
230Vac
/
100 % Load
100mVpp Max
57.5mVpp
58.8mVpp
56.7mVpp
E. Inrush Current
Test Result :
Test condition
Spec.
Reading 1
Reading 2
Reading 3
100 % Load
30A Max.
27.8 A
27.9A
27.5A
230Vac / 100 % Load
60A Max
42.6 A
43.2A
43.3A
Spec.
Reading 1
Reading 2
Reading 3
100 % Load
4A Max.
2.688 A
2.658 A
2.701A
230Vac / 100 % Load
4A Max.
3.011 A
2.912 A
3.001A
Spec.
Reading 1
Reading 2
Reading 3
100 % Load
Auto Recovery
OK
OK
OK
230Vac / 100 % Load
Auto Recovery
OK
OK
OK
Spec.
Reading 1
Reading 2
Reading 3
≦ 0.3 W
0.27W
0.26W
0.27W
115Vac
/
F. Over Current Protection
Test Result :
Test condition
115Vac
/
G. Short Circuit Protection
Test Result :
Test condition
115Vac
/
H. Input Power Consumption(No Load)
Test Result :
Test condition
230Vac
/
0 % Load