0-F095-1-000

0-F095-1-000
Product Information Packet
Model AHP-450HC
24 VDC Solid State Heat/Cool Air Conditioner
Without Temperature Control
Part #0-F095-1-000
Thank you for your purchase. Information has been enclosed regarding the
installation, specifications, and wiring of your solid-state assembly.
Please read and follow all instructions carefully before installation. Only qualified
technicians should install this equipment.
If you have any questions regarding your equipment, please do not hesitate to
call us at 773-342-4900, and we will be happy to assist you. We are open from
8:00 am-4:30 pm Central Time.
Included in this packet you will find:
Product Literature and Specifications
Assembly Drawing # SK110822
Wiring Drawing # SK110526
Installation Drawing # SK110823
Warranty Information
Important Installation Notes for Air
Mounting Styles: Both ‘thru mount’ and ‘flush mount’ units can be
positioned in any orientation and on any enclosure surface. It is important
to consider interior air flow patterns when determining the mounting
location. Also of importance is an unrestricted flow of ambient air thru
the hot side heat exchanger. Ease of access and inspection
must be considered for those applications in particularly severe
environments which may require occasional maintenance.
Ambient
Vertical (Side/Front/Back) Mounting:
Seal
Internal Air
Path
Air
Path
Vertical mounting refers to the vertical direction of the cold
side or interior fins and is recommended for applications with
high humidity, poor and incomplete cabinet seals or any
condition which may cause the cold side fins to be maintained
at temperatures below the dew point for long periods of time
allowing for the formation of condensation. The vertical fin
direction provides a drip path whereupon condensation can be
collected via a moisture removal system (standard on FHPunits) or a drip pan positioned below the cold side fins. Drip pans are
optional for thru mount units.
Enclosure
Condensate Removal System:
All FHP-Series and AHP-1400 air conditioners contain a built-in condensate removal system. The condensate kit
consists of a antifungal sponge with a condensate wick. PVC tubing is also provided for drainage. Drip pans are
optional for thru mount units which must be evaluated on an individual basis. Equations defining a relationship
between the cold side fin and enclosure temperatures are provided to assist in the evaluation.
Top Mounting:
Though often the easiest location to mount it is often the most difficult to protect from condensation in this orientation
due to the fin orientation, gravity and any susceptible components below. If a drip pan is employed by the end user use
caution to place the pan far enough away from the internal fan to minimize the restriction of air flow. The pan should
cover the fin ends as well as the fan area. When there is a choice, the vertical orientation is preferred by most
users.
Maintenance:
Since the technology is solid-state, there are no filters, compressors, or fluorocarbons to maintain. The only moving
parts are the fans. It is recommended for harsh or dirty environments that the heat sinks be cleaned from time to
time. This can be accomplished by directing compressed air over the external fins or on NEMA 4 versions by hosing
the unit down. This will increase the overall life and performance of the system.
Cautions:
Take care when mounting not to damage the seal between the hot and cold side sinks. Do not attempt to mount a unit
to a warped surface or try to make the units mounting surface conform to an unflat surface. Do not pinch or damage
any leads when mounting. Do not over tighten any installation screw, use reasonable force. Always mount with any
condensate drain down. Do not compress the cold side between the hot side and any other surface. Do not obstruct
the airflow on either side. When mounting consider the natural air flows of the enclosure. Connect power only after the
installation is complete.
Notes on condensation:
Condensation occurs at the cold side fins when the surface temperature goes below the dew point. To reduce or
remove condensate, consider the following:
• Regulate the Fin Temperature above the Dewpoint.
• Keep Enclosure Closed and Sealed from Outside Humidity.
• Use Desiccant (Moisture absorbing Granules.)
• Employ Condensate Removal System/Drip Pans.
If you have any questions regarding your installation, Please feel free to contact our technical department for
assistance at 773-342-4900.
Catalog 2012 AC.qxp
10/24/2012
2:08 PM
Page 62
AHP-450 Air Conditioner/Heat Exchanger
Air Cooled
Through Mounted
Nema-12, 4, 4X
24 VDC
High Efficiency
210 BTU/HR
FEATURES
• Compact (only 10” X 5.84” X 7.75”)
• Mounts and operates in any orientation:
horizontal, vertical, etc.
• Low vibration and noise
• No moving parts except fans
• Environmentally safe
• No compressor, fluorocarbons or filters
• Virtually maintenance-free operation
• Stainless steel exterior housing
• Efficient heat exchanger mode (ECO-Mode)
• Weight 14 LBS.
INCLUDES
CONTROL TEMPERATURES
Active Cooling
Heat Exchanger (ECO-Mode)
Active Heating
Typical Hysteresis
Operating Ambient
Operating Enclosure
35 °C
25 °C
10 °C
5 °C
-40/+70 °C
-10/+60 °C
• Temperature controller
• Mounting gasket
• Mounting hardware
• Power input leads
• Power saving heat exchanger mode (ECO-Mode)
POWER INPUTS
Voltage
Current, Active
Current, ECO-Mode
24 VDC
2.3 AMPS
0.3 AMPS
PERFORMANCE RATINGS
Cooling (Traditional)
Cooling (Din 3168)
Cooling COP (at L35 L35)
Heating (Traditional)
Heating (Din 3168)
Heating COP
207 BTU/HR
62 WATTS
1.12
> 188 BTU/HR
> 55 WATTS
> 1.0
CONFIGURATIONS
MODEL
PART NUMBER
NOTES
TEMPERATURE
CONTROL
AHP-450
0-F0J5-0-000
Cool only, industrial fans
AHP-450HC
0-F095-1-000
Heat/Cool, industrial fans
AHP-450HC
0-F0I5-1-000
Heat/Cool, industrial fans
AHP-450XE
0-F0J5-4-000
Cool only, sealed hot side fan
AHP-450XEHC
0-F095-5-000
Heat/Cool, sealed hot side fan
AHP-450XEHC
0-F0I5-5-000
Heat/Cool, sealed hot side fan
AHP-450X
0-F0J5-2-000
Cool only, Mil. grade hot side fan
AHP-450XHC
0-F095-3-000
Heat/Cool, Mil. grade hot side fan
AHP-450XHC
0-F0I5-3-000
Heat/Cool, Mil. grade hot side fan
AHP-450XM
0-F0J5-2-010
Cool only, Mil. grade fans
AHP-450XMHC
0-F095-3-010
Heat/Cool, Mil. grade fans
AHP-450XMHC
0-F0I5-3-010
Heat/Cool, Mil. grade fans
* For controller options contact TECA; Heating function via reverse polarity (controller dependent)
TECA
1-888-TECA-USA (832-2872)
TC-4F
None*
TC-7F
TC-4F
None*
TC-7F
TC-4F
None*
TC-7F
TC-4F
None*
TC-7F
ENVIRONMENT
NEMA-12, IP 52
NEMA-12, IP 52
NEMA-12, IP 52
NEMA-4, IP 56
NEMA-4, IP 56
NEMA-4, IP 56
NEMA-4X, IP 56
NEMA-4X, IP 56
NEMA-4X, IP 56
NEMA-4X, IP 56
NEMA-4X, IP 56
NEMA-4X, IP 56
www.teca-usa.com
Catalog 2012 AC.qxp
10/24/2012
2:09 PM
Page 63
Air Conditioner - Air Cooled
AHP-450
PERFORMANCE CURVE
MOUNTING STYLE
Through Mounted
ENVIRONMENTS SERVED
NEMA-12
IP 52
NEMA-4,4X IP 56
RATING (TRADITIONAL)
AHP-450 210 BTU/hr @ 0 °F ⌬T
297 BTU/hr @ +20 °F ⌬T
RATING (DIN 3168)
AHP-450 62 Watts L35 L35
28 Watts L35 L50
Equation of Line: y=⌬T(°C) x=Capacity (Watts)
Ambient Temp
20°C
60°C
AHP-450
y=.42x-25.6
y=.42x-27.5
Air Flow Pattern
DIMENSIONS
www.teca-eu.com
1-888-TECA-USA (832-2872)
TECA
LIMITED WARRANTY
In the event a defect in material or workmanship is discovered in any of
TECA’s products within one year after the date they are delivered to Buyer,
and if: (a) TECA is notified of the defect in writing by certified mail within 14
days of the date of discovery; (b) TECA may then either, at its sole discretion,
inspect the product at Buyer’s location, or require that the product be made
available at Buyer’s expense at TECA’s premises for TECA’s inspection within
14 days of the date of notification; and (c ) the products are defective and the
defects result from faulty materials and/or workmanship and not in any way
from accident, misuse, misapplication, mishandling, modification, or alteration
by the Buyer or the shipper, then TECA shall, at its sole option, repair or
exchange defective products free of charge to Buyer, or credit to buyer the
price of the defective products. ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, ARE EXCLUDED, INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. IN NO EVENT SHALL TECA BE LIABLE FOR
ANY CLAIM BASED UPON BREACH OF EXPRESS OR IMPLIED
WARRANTY OR ANY OTHER DAMAGES WHETHER SPECIAL, INDIRECT,
INCIDENTAL, CONSEQUENTIAL, LOST PROFITS, BUSINESS
INTERRUPTION, OR LOSS OF BUSINESS OR CUSTOMER
RELATIONSHIPS.
RETURNED GOODS, RESTOCKING CHARGES
In order to return merchandise for any reason ( repair, replacement, or credit)
a return authorization number must be issued by TECA. New merchandise
may not be returned for credit beyond 60 days from shipment. Charges for
incidental or other damages may also be made. All returned goods must be
sent freight prepaid. A restocking charge of 15% will apply. On special
equipment and custom modified equipment orders, additional incremental
cancellation charges may be made.
Was this manual useful for you? yes no