CliQ DIN Rail Power Supply 12V 100W 1 Phase / DRP012V100W1AA

CliQ DIN Rail Power Supply 12V 100W 1 Phase / DRP012V100W1AA
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
Highlights & Features
–
–
–
–
–
–
Universal AC input voltage
Power will not de-rate for the entire input voltage range
Power Boost of 150% for 3 seconds
Full corrosion resistant aluminium chassis
Hazardous Locations approval to ATEX and Class I, Div 2
Overvoltage / Overcurrent / Over Temperature / Short Circuit
Protections
Safety Standards
CB Certified for worldwide use
Model Number:
DRP012V100W1AA
Unit Weight:
0.64 kg
Dimensions (L x W x D): 121 x 50 x 118.7 mm
General Description
The DRP012V100W1AA is part of the CliQ DIN rail power supply series from one of the world’s leading power supply companies, Delta
Electronics Group. The rugged metal case is made to withstand harsh industrial environments, which is both shock and vibration
resistant according to IEC 60068-2 standard. The product operates within a wide temperature range from -20°C to +80°C. The
DRP012V100W1AA features universal AC input voltage range from 85Vac to 264Vac and the power will not de-rate for the entire input
voltage range. The single phase power supply unit includes overvoltage, overcurrent, over temperature and short circuit protections.
The product features built-in Power Boost of 150% for 3 seconds. Such feature enables reserve power to be always available for
reliable startup of loads with high inrush current, thus eliminating the need of a more expensive power supply unit at higher power
rating. Another great feature is the conformal coating on the PCBA which allows DRP012V100W1AA to be certified to ATEX and
Class I, Div 2 for use in hazardous locations.
Model Information
CliQ DIN Rail Power Supply
Model Number
Input Voltage Range
Output Voltage
Output Current
DRP012V100W1AA
85-264Vac (120-375Vdc)
12Vdc
8.33A
Model Numbering
DR
P
012V
100W
1
A
A
DIN Rail
Power Supply
Output Voltage
Output Power
Single Phase
CliQ Series
Metal Case
1
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
Specifications
Input Ratings / Characteristics
Nominal Input Voltage
100-240Vac
Input Voltage Range
85-264Vac
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
DC Input Voltage Range*
120-375Vdc
Input Current
< 2.50A @ 115Vac, < 1.50A @ 230Vac
Efficiency at 100% Load
> 85.5% @ 115Vac, > 87.5% @ 230Vac
Max Inrush Current
< 100A @ 115Vac, No Damage @ 230Vac
Leakage Current
< 1mA @ 240Vac
*Safety approval according to IEC/EN/UL 60950-1.
Output Ratings / Characteristics
Nominal Output Voltage
12Vdc
Output Voltage Tolerance
± 2% (initial set point tolerance from factory)
Output Voltage Adjustment Range
11-14Vdc
Output Current
8.33A (continuously operating at 12V)
12.495A (Power Boost for 3 seconds at 12V, refer to the
details in the Functions section)
Output Power
100W (continuously operating at 12V)
150W (Power Boost for 3 seconds at 12V, refer to the
details in the Functions section)
Line Regulation
< 0.5% typ. (@ 85-264Vac input, 100% load)
Load Regulation
< 1% typ. (@ 85-264Vac input, 0-100% load)
PARD (20MHz)
< 100mVpp
Rise Time
< 40ms @ nominal input (100% load)
Start-up Time
< 600ms @ nominal input (100% load)
Hold-up Time
> 22ms @ 115Vac,
> 110ms @ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 0-100% load
Start-up with Capacitive Loads
10,000µF Max
2
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
Mechanical
Case Cover / Chassis
Aluminium
Dimensions (L x W x D)
121 x 50 x 118.7 mm
Unit Weight
0.64 kg
Indicator
Green LED (DC OK)
Cooling System
Terminal
Wire
Convection
Input
3 Pins (Rated 300V/20A)
Output
2 Pins (Rated 300V/20A)
Input / Output
AWG 18-14
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
Noise (1 Meter from power supply)
Sound Pressure Level (SPL) < 40dBA
Environment
Surrounding Air Temperature
Power De-rating
Operating
-20°C to +80°C
Storage
-25°C to +85°C
Vertical Mounting
> 50°C de-rate power by 2.5% / °C
Horizontal Mounting
> 50°C de-rate power by 2.5% / °C,
> 70°C de-rate power by 4% / °C
Operating Humidity
5 to 95% RH (Non-Condensing)
Operating Altitude
0 to 2,000 Meters (@ 50°C)
Shock Test (Non-Operating)
IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms,
1 time per direction, 6 times in total
Vibration (Non-Operating)
IEC 60068-2-6, 10Hz to 500Hz @ 50m/S² (5G peak);
90 min per axis for all X, Y, Z direction
Pollution Degree
2
Protections
Overvoltage
16V, +10% / -5%, SELV Output, Hiccup Mode,
Non-Latching (Auto-Recovery)
Overload / Overcurrent
> 150% of rated load current, Hiccup Mode,
Non-Latching (Auto-Recovery)
Over Temperature
< 80°C Surrounding Air Temperature @ 100% load,
Non-Latching (Auto-Recovery)
Short Circuit
Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed)
Protection Against Shock
Class I with PE* connection
*PE: Primary Earth
Reliability Data
MTBF
> 500,000 hrs. as per Telcordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
3
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
Safety Standards / Directives
Electrical Equipment in Power Installations
EN 50178 / IEC 62103
Electrical Safety
TUV to EN 60950-1, UL/cUL recognized to UL 60950-1
and CSA C22.2 No. 60950-1 (File No. E191395),
CB scheme to IEC 60950-1
UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01
(File No. E315355), CSA to CSA C22.2 No. 107.1-01
(File No. 181564)
cCSAus to CSA C22.2 No. 213-M1987, ANSI / ISA
12.12.01:2011
Class I, Division 2, Group A, B, C, D T4, Ta= -20°C to
+80°C (> +50°C derating)
Industrial Control Equipment
Hazardous Location / ATEX
EN 60079-0:2012, EN 60079-15:2010 (
II 3G Ex nA
IIC T4 Gc, Ta= -20°C to +80°C (> +50°C derating))
Certificate No. EPS 12 ATEX 1 491 X
II 3G ATEX 94/9/EC
CE
In conformance with EMC Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC
In conformance with Equipment for explosive
atmospheres (ATEX) directive 94/9/EC
RoHS Directive 2011/65/EU Compliant
Material and Parts
Galvanic Isolation
4
Input to Output
4.0KVac
Input to Ground
1.5KVac
Output to Ground
1.5KVac
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
EMC
EMC / Emissions
CISPR 22, EN 55022, CISPR 11, EN 55011,
FCC Title 47: Class B
Immunity to
EN 55024, EN 61000-6-1, EN 61000-6-2
Level 4 Criteria A1)
Air Discharge: 15kV
Contact Discharge: 8kV
Level 3 Criteria A1)
80MHz-1GHz, 10V/M, 80% modulation (1kHz)
1.4GHz-2GHz, 3V/M, 80% modulation (1kHz)
2GHz-2.7GHz, 1V/M, 80% modulation (1kHz)
Electrostatic Discharge
IEC 61000-4-2
Radiated Field
IEC 61000-4-3
Electrical Fast Transient / Burst
IEC 61000-4-4
Level 3 Criteria A
2kV
Surge
IEC 61000-4-5
Conducted
IEC 61000-4-6
Level 3 Criteria A
2)
Common Mode : 2kV
3)
Differential Mode : 1kV
Level 3 Criteria A1)
150kHz-80MHz, 10Vrms
Power Frequency Magnetic Fields
IEC 61000-4-8
1)
1)
Criteria A1)
30A/Meter
Voltage Dips
IEC 61000-4-11
100% dip; 1 cycle (20ms); Self Recoverable
Low Energy Pulse Test (Ring Wave)
IEC 61000-4-12
Harmonic Current Emission
Level 3 Criteria A1)
2)
Common Mode : 2kV
Differential Mode3): 1Kv
IEC/EN 61000-3-2, Class A
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)
5
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
Block Diagram
Device Description
1)
2)
3)
4)
5)
6
Input terminal block connector
Output terminal block connector
DC Voltage adjustment potentiometer
DC OK control LED (Green)
Universal mounting rail system
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
Dimensions
L x W x D: 121 x 32 x 120 mm
Engineering Data
De-rating
Note
1.
2.
3.
4.
Fig. 1
De-rating for Vertical Mounting Orientation
> 50°C de-rate power by 2.5% / °C
De-rating for Horizontal Mounting Orientation
> 50°C de-rate power by 2.5% / °C,
> 70°C de-rate power by 4% / °C
7
5.
Power supply components may degrade, or
be damaged, when the power supply is
continuously used outside the shaded region,
refer to the graph shown in Fig. 1.
If the output capacity is not reduced when the
surrounding air temperature > 50°C, the
device may run into Over Temperature
Protection. When activated, the output
voltage will go into bouncing mode and will
recover
when
the
surrounding
air
temperature is lowered or the load is reduced
as far as necessary to keep the device in
working condition.
In order for the device to function in the
manner intended, it is also necessary to keep
a safety distance of 20mm (for Vertical
Mounting) or 50mm (for Horizontal Mounting)
with adjacent units while the device is in
operation.
Depending
on
the
surrounding
air
temperature and output load delivered by the
power supply, the device can be very hot!
If the device has to be mounted in any other
orientation, please do not hesitate to contact
info@deltapsu.com for more details.
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
Output De-rating VS. Input Voltage

No output power de-rating across the entire
input voltage range
Assembly & Installation
The power supply unit (PSU) can be mounted on 35mm DIN rails in accordance with EN 60715. The device should be installed with
input terminal block at the bottom.
Each device is delivered ready to install.
Mounting
Dismounting
Fig. 2.1 Mounting
Fig. 2.2 Dismounting
Snap on the DIN rail as shown in Fig. 2.1:
1. Tilt the unit upwards and insert it onto the DIN rail.
2. Push downwards until stopped.
3. Press against the bottom front side for locking.
4. Shake the unit slightly to ensure that it is secured.
To uninstall, pull or slide down the latch with screw driver as
shown in Fig. 2.2. Then slide the power supply unit (PSU) in
the opposite direction, release the latch and pull out the power
supply unit (PSU) from the rail.
In accordance to EN 60950 / UL 50950, flexible cables require ferrules.
Use appropriate copper cables designed to sustain operating temperature of at least 75°C or more to fulfill UL requirements.
For stranded wires it is recommended to use suitable lug to crimp wires.
8
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
Safety Instructions

–
–
–
–
–
–
–
–
–
–
–
9
Vertical Mounting

Horizontal Mounting
ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit. If mains are not
turned OFF, there is risk of explosion / severe damage.
To guarantee sufficient convection cooling, keep a distance of 50mm above and below the device as well as a lateral
distance of 20mm (for Vertical Mounting) or 50mm (for Horizontal Mounting) to other units.
Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power
supply. Risk of burns!
Only plug in and unplug connectors when power is turned off!
DO NOT insert any objects into the unit.
Hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. Do not touch the unit during
this time.
The power supplies are built in units and must be installed in a cabinet or room (condensation free environment and indoor
location) that is relatively free of conductive contaminants.
CAUTION: “For use in a controlled environment”.
The power supplies unit must be installed in an IP54 enclosure or cabinet in the final installation. The enclosure or cabinet must
comply with EN 60079-0 or EN 60079-15.
Warning: Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2.
Warning: Explosion Hazard - Do not disconnect equipment or adjust potentiometer unless the power has been switched off or the
area is known to be non-hazardous.
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
Functions
■ Graph illustrating the Start-up Time, Rise Time, and Hold-up Time
Start-up Time
The time required for the output voltage to reach 90% of its set value, after the input voltage is applied.
Rise Time
The time required for the output voltage to change from 10% to 90% of its set value.
Hold-up Time
Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time
required for the output to reach 90% of its set value, after the input voltage is removed.
Inrush Current
Dynamic Response
Inrush current is the peak, instantaneous, input current measured
and, occurs when the input voltage is first applied. For AC input
voltages, the maximum peak value of inrush current will occur
during the first half cycle of the applied AC voltage. This peak
value decreases exponentially during subsequent cycles of AC
voltage.
The power supply output voltage will remains within ±5% of its
steady state value, when subjected to a dynamic load from 0 to
100% of its rated current.
10
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
Power Boost
Power Boost is the reserve power available
constantly that allows reliable startup to support
sudden and short spike of loads with high inrush
current typically during turn on to remove the
need of more expensive higher rated power
supply unit. After the output has reached its
steady state set value, the power supply can
support surge loads with a higher short-term
power demand up to 150% of maximum rated
load (IO Max), for a maximum duration of 3
seconds. The Power Boost is also available to
repeatedly basis with according to the condition of
an average (R.M.S) output power shall not
exceed continuous operating condition or refer to
duty cycle calculation below.
𝐷𝑢𝑡𝑦 𝑐𝑦𝑐𝑙𝑒 (%) =
𝑇𝑃
𝑇𝑜𝑡𝑎𝑙 𝑇𝑖𝑚𝑒
𝐴𝑣𝑒𝑟𝑎𝑔𝑒 𝑂𝑢𝑡𝑝𝑢𝑡 𝑃𝑜𝑤𝑒𝑟 (𝑃𝐴𝑣𝑔 ) =
OR
𝑁𝑜𝑛-𝑃𝑒𝑎𝑘 𝑃𝑜𝑤𝑒𝑟 =
(𝑃𝑜𝑤𝑒𝑟 𝐵𝑜𝑜𝑠𝑡 × 𝑇𝑃 ) + (𝑁𝑜𝑛-𝑃𝑒𝑎𝑘 𝑃𝑜𝑤𝑒𝑟 × 𝑇𝑁 )
𝑇𝑜𝑡𝑎𝑙 𝑇𝑖𝑚𝑒
�𝑃𝐴𝑣𝑔 × 𝑇𝑜𝑡𝑎𝑙 𝑇𝑖𝑚𝑒� − (𝑃𝑜𝑤𝑒𝑟 𝐵𝑜𝑜𝑠𝑡 × 𝑇𝑃 )
𝑇𝑁
An example of Power Boost and Average Output Power

Power Boost
Peak Power
(WP)
Power Boost
Duration (TP)
Duty Cycle
Non-Peak
Power (WN)
Non-Peak Power
Duration (TN)
Total Time
(T)
150%
150
3 sec
10%
94W
27 sec
30 sec
150%
150
3 sec
35%
73W
5.5 sec
8.5 sec
120%
120
6 sec
20%
95W
24 sec
30 sec
120%
120
6 sec
35%
89W
11 sec
17 sec
It is not recommended to prolong the duration of Power Boost to be longer than the specified duty cycle calculation, this may cause
damage to the PSU.
11
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
Overload & Overcurrent Protections
Overvoltage Protection
The power supply’s Overload (OLP) and Overcurrent (OCP)
Protections will be activated when output current exceeds 150%
of IO (Max load). In such occurrence, the VO will start to droop and
once the power supply has reached its maximum power limit, the
protection is activated and the power supply will go into “Hiccup
mode” (Auto-Recovery). The power supply will recover once the
fault condition of the OLP and OCP is removed and IO is back
within the specifications.
The power supply’s overvoltage circuit will be activated when its
internal feedback circuit fails. The output voltage shall not exceed
its specifications defined on Page 3 under “Protections”. The
nd
power supply doesn’t shut down but goes in 2 level regulation at
15-16Vdc and continue to deliver the power. According to high
output voltage which will be operating > 100% of rated load (16V
× rated output current), if this condition persists, the power supply
will sense OTP (Over Temperature Protection) and will go under
hiccup mode. The power will return to normal operation once the
fault condition is removed.
It is not recommended to prolong the duration of IO when it is
<150% but >100%, since it may cause damage to the PSU.
Short Circuit Protection
The power supply’s output OLP/OCP function also provides
protection against short circuits. When a short circuit is applied,
the output current will operate in “Hiccup mode”, as shown in the
illustration in the OLP/OCP section on this page. The power
supply will return to normal operation after the short circuit is
removed.
12
Over Temperature Protection
As mentioned above, the power supply also has Over
Temperature Protection (OTP). In the event of a higher operating
temperature at 100% load, the power supply will run into OTP
when the operating temperature is beyond what is recommended
in the de-rating graph. When activated, the output voltage will go
into bouncing mode until the temperature drops to its normal
operating temperature as recommended in the de-rating graph.
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
12V 100W 1 Phase / DRP012V100W1AA
Others
Delta RoHS Compliant
Restriction of the usage of hazardous substances
The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead,
mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and
electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in
electrical and electronic equipment”.
This product conforms to this standard.
Conformal Coating
The Protective Coating Technology
Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including
under device, and prevents leakage. The conformal coating dipping can be applied to PCBAs or circuit board.
The coating preserves the performance of precision electronic primarily by preventing ionizable contaminants
such as salt from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem
especially in highly conversing atmosphere.
PFC – Norm EN 61000-3-2
Line Current Harmonic content
Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor.
In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying
to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial
aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard,
therefore, it is important to know whether it is mandatory to meet this standard for a specific application.
13
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (April 2015, Rev. 04)
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising